VeriSafe Absence of Voltage Tester The safe way to verify the absence of voltage

Similar documents
The safe way to verify the absence of voltage.

Easy to use, initiate test with the push of a button No additional tools required Provides visual alert to abnormal power conditions

Product Bulletin. VeriSafe Absence of Voltage Tester. The Safe Way to Verify the Absence of Voltage.

Product Bulletin. VeriSafe Absence of Voltage Tester. The Safe Way to Verify the Absence of Voltage.

Designed for testing three-phase circuits up to 600V Install on line or load side of electrical disconnect Detects absence of AC and DC voltage

Product Bulletin. VeriSafe Absence of Voltage Tester. The Safe Way to Verify the Absence of Voltage.

NECA S System Approach to Electrical Safety for NFPA 70E

NECA S System Approach to Electrical Safety for NFPA 70E

NFPA 70E Edition Update

6/23/ National Electrical Contractors Association and Intec, Inc.

NFPA 70E Electrical Safety & Arc Flash Training

Arc Flash Protection Training - NFPA 70e Electrical Safety

NECA. Standard for Electrical Safety in the Workplace

2012 Edition. Tech Topics: Standards & Codes. Note 4, Issue 1. Points of Interest: Introduction. Background. Changes to Definitions in Article 100

Safety requirements for voltage testing instruments

IEEE Std IEEE Recommended Practice for Electrical Installations on Shipboard Safety Considerations

NATIONAL ELECTRICAL CODE (NEC) & NFPA 70E ARC FLASH ELECTRICAL SAFETY

PROTECTING AGAINST ARC FLASH HAZARDS

May is National Electrical Safety Month, an AND THE ELECTRICAL INSPECTOR. by Mark Hilbert and Laura L. Hildreth

T22 - Arc Flash Hazards and Arc Resistant Equipment- Understanding the Standards

NFPA 70E. Electrical Safety in the Workplace. KTR Associates. Joseph Deane, PE. Engineering Solutions

Pilz Safety Lockout System (PSLS)

HESNI ANNUAL CONFERENCE May 3, 2012 Aramark Conference Center, Downers Grove

NFPA 70E Elevates Safety. with Heightened Risk Awareness

SEL Arc-Flash Solutions

Electrical Safety Program

SECTION AUTOMATIC TRANSFER SWITCHES

SEL Arc-Flash Solutions

SUMMARY: Policy Title: Electrical Safety Work Practice Program. Policy Number: UNIV-EHS 430 Policy Approved: January 2014

Electrical Hazards and NFPA-70E: Protecting Your Employees

Implementing an Energized Electrical Work Program. SESHA Hill Country Chapter. Brett Jay Davis, PE Zephyr Environmental Corporation

Compliance without compromise Safety without sacrifice

Centennial Energized Electrical Work Permit Instructions

Arc Flash Analysis: IEEE Method versus the NFPA 70E Tables July 2017 / 1910DB1702

Brian McCauley December 2017

COMPLIANCE without compromise SAFETY without sacrifice YOUR RESULTS MATTER

How many time has your company been asked by an owner or customer to work on equipment energized?

SUGGESTED SPECIFICATION For Series 300 Manual Transfer Switches (3MTS)

The Basics Arc Flash Protection

17 TH APRIL 2017 Switch Board Monitoring Protecting Switchboard. Courtesy of ABB. Paul Lee

IMPROVE SAFETY WITH ARC FLASH LABELING COMPLY WITH THE 2015 NFPA 70E REGULATIONS

Arc Flash Codes & Compliance: What You Need to Know to Deliver Both Protection and Performance

Arc Flash Analysis. Arc flash hazard analysis is required to determine the risk to personnel, warn them of the

Electrical Safety Program.

National Electrical Code

NECA & Salisbury Assessment Solutions Partnership

PCD/PEM Power Conversion Department - Equipment Lockout Procedure

Your Global Automation Partner. Minimizing Arc Flash Exposure in Industrial Applications. White Paper - W1000

ENERGY CONTROL LOCKOUT/TAGOUT PROGRAM PLAN

CONTENTS AUTOMATIC TRANSFER SWITCHES

Professional Seminar. The Electrically Safe Workplace. Understanding the NFPA 70E Electrical Safety Standard, 2012 Edition ...

Electrical Safety Compliance: NFPA 70E

INTERNATIONAL STANDARD

F&S Control of Hazardous Energy Program

2014 National Electrical Code & NFPA 70E/Arc Flash

STANDARDS UPDATE NOTICE (SUN) ISSUED: August 23, 2017

9/7/2010. Chapter , The McGraw-Hill Companies, Inc. AND BONDING. 2010, The McGraw-Hill Companies, Inc.

SECTION AUTOMATIC TRANSFER SWITCHES

Rutgers Environmental Health and Safety (REHS)

ANSI/NETA Standards Update

Electrical Safety for Facility Managers and Building Owners

Arc Fault Detection Devices (AFDDs) Protecting People and Property

Supplement. Title: 365 Users Supplement Issue: 8 Part Number: Issue Date: 7/16 Print Date: August 2010 Page Count: 6 Revision/Date:

NFPA 70E Electrical Safety in the Workplace

NFPA 70E Standard for Electrical Safety in the Workplace. EEI Safety and Health Meeting May 2011

For technical questions, contact: Grace Engineered Products Inc./ 5001 Tremont Ave, Davenport, IA /

SECTION (16460) - LOW-VOLTAGE TRANSFORMERS

How to reduce exposure to arc flash hazards

Wireless Occupancy Sensor:

Operation & Maintenance Manual

Occupational Safety Next Review Date: 12/20/17. Scope: University Wide Original Creation Date: 2009

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

ADIPEC 2013 Technical Conference Manuscript

User Guide. Luxxor. 35 LED Light Source Fax: Tremont Street, Rochester, New York gradientlens.

CurrentGuard TM. Installation, Operation and Maintenance Manual. CurrentGuardTM. Flush Mount. Surge Protective Devices A00

Welcome DISCLAIMER. Testing Electric Fire Pumps You Need to Understand the Arc Flash Hazard 5/1/ NFPA Conference & Expo

4 & 8-POINT ANNUNCIATORS Instruction Manual

Safety Meeting Topic #37 NFPA 70E What is it?

Reducing Arc Flash Risks with Electrical Maintenance Safety Devices - Part 2

*************************************************************************** SECTION D50 ELECTRICAL 02/18

Revitalize Building Mechanical Systems (4619)

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection

Electrical Safety Requirements

This page intentionally left blank

Protection from Electric Shock and Arc Flash. Meeting OSHA Regulations and NFPA 70E Standards.

Business Emergency Plan

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

LV-5 Direct Contact Low Voltage Detector and LV-5/K01 Kit including LV-PT Tester, Holster and Available Accessories

Webinar November 12, 2014

[Project Location] SECTION FUSION STAINLESS STEEL DOME HOUSING MOOG VIDEOLARM A&E SPECIFICATION SSDP SERIES

Operation and use. Functions and characteristics

Arc Fault Sensing Device Testing

Online Training Catalog - Employee Safety and Health. October 2013

Promoting Electrical Safety through NFPA 70E Standards Adherence

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

SAFETY MANUAL. X2200 UV, X9800 IR, X5200 UVIR SIL 2 Certified Flame Detectors

Multi-Gas-Controller MGC2

Arc Fault Sensing Device: Residential Testing Scenario

Training, Assessment, Consultants for Hazardous & Industrial Areas

Transcription:

VeriSafe Absence of Voltage Tester The safe way to verify the absence of voltage www.panduit.com/verisafe

What is an Absence of Voltage Tester? Absence of Voltage Testers (AVTs) are permanently-mounted test devices used to verify a circuit is de-energized prior to opening an electrical enclosure Verify the absence of phase-to-phase and phase-to-ground AC and DC voltage Built-in test circuit verifies operation on a known voltage source before and after absence of voltage test Contain provisions to ensure tester is properly installed and in direct contact with the circuit at time of testing Utilize active indications and functional safety principles Automated test sequence helps reduce operator errors Listed to UL 1436 AVTs are a NEW product category added to UL 1436 in September 2016 2 Panduit Corp. March 2016

Significance of Verifying the Absence of Voltage 24,000 electrical injuries in the US workplace (2003-2012) [1] 35% due to contact with wiring, transformers, or other electrical components [1] 60% of incidents with key words electric arc and burn occurred at low voltages (<1000V), with the majority on three phase systems [2] 20% of incidents or 500 electrical injuries per year or $120-200 million annually Leading cause: performing work without turning off power and verifying a de-energized condition [2] [1] US Department of Labor, "Bureau of Labor Statistics Occupational Injuries and Illnesses," [Online]. Available: http://www.bls.gov/iif/data.htm. [Accessed 16 April 2015]. [2] C. M. Wellman, "OSHA Arc-Flash Injury Data Analysis," in 2012 IEEE IAS Electrical Safety Workshop, Daytona Beach, FL, 2012. 3 Panduit Corp. March 2016

Verifying a De-Energized Condition Step (5) of NFPA 70E Article 120.1: Use an adequately rated test instrument to test each phase conductor or circuit part to verify it is de-energized. Test each phase conductor or circuit part both phase-to-phase and phase-toground. Before and after each test, determine that the test instrument is operating satisfactorily through verification on a known voltage source. 2015 Edition Isolate Energy Source & LOTO Select Test Instrument Test the Tester Check for Voltage Test the Tester Perform Work 4 Panduit Corp. March 2016

What really happens Verifying the absence of voltage is a critical task that is part of almost every job Over a 5-year period [1] 18% of the facilities surveyed had a personal injury resulting from use of a voltage test instrument 37% reported near misses 12% experienced plant interruptions When electricians and technical personnel at a large chemical company were asked, How do you test for the absence of voltage? more than 90% did not know how to perform a thorough test. [2] 55% experienced a voltage testing injury or near miss with handheld testers! [1] [1] H. L. Floyd and B. J. Nenninger, "Personnel Safety and Plant Reliability Considerations in the Selection and Use of Voltage Test Instruments," IEEE Transactions on Industry Applications, vol. 33, no. 2, pp. 367-373, 1997. [2] K. Crawford and N. K. Haggerty, "Test Before Touch: Seems Easier Said Than Done," IEEE Industry Applications Magazine, pp. 32-39, May/June 2008. 5 Panduit Corp. March 2016

Now there is a better way! VeriSafe Absence of Voltage Tester The safe way to verify the absence of voltage Designed for low voltage equipment up to 600V AVT System Cable Isolation Module & Sensor Leads (with dry contacts for optional output) Indicator Module (external to enclosure) VeriSafe Absence of Voltage Testers use active visual indicators that convey the status of voltage inside electrical equipment before it is accessed, reducing exposure to electrical hazards and protecting workers. 6 Panduit Corp. March 2016

VeriSafe Absence of Voltage Tester Portable Testers Comparison of Test Methods Select Tester Test the Tester Check for Voltage Retest the Tester Perform Work Possible Exposure to Electrical Hazards Activate the VeriSafe Absence of Voltage Tester Open Panel Automatically Performed in Sequence No Exposure to Electrical Hazards 1. Test the Tester Verify tester can detect voltage in the desired range 2. Verify Installation Verify tester is in contact with the circuit 3. Check for Voltage Test phase-to-phase and phase-to-ground 4. Verify Installation 5. Retest the Tester 7 Panduit Corp. March 2016 Re-verify the installation Re-test the tester

Product Differentiation Voltage Testers Typically handheld Detect presence and absence of voltage Contact and non-contact versions Voltage Indicators Typically installed Only warn of voltage presence Do not guarantee absence of voltage VeriSafe Absence of Voltage Testers Test without exposure Self-contained with known voltage source Built-in pre-/post-verification test Automated test sequence Detects AC and DC without need to adjust settings Active indication for absence of voltage SIL 3 safety functions Supports compliance with NFPA 70E (UL 1436 listing) Install in direct contact with circuit (no fusing) 8 Panduit Corp. March 2016

Applicable Standards Product Safety UL 1436, UL 61010 & UL 508 Product safety & certification standards NEW category for Absence of Voltage Testers added to UL 1436 Functional Safety IEC 61508 SIL 3 SIL is a measure of reliability for hardware & software Ensures dangerous failures are detected and controlled in a safe way Employee Work Practices NFPA 70E* 2018 Edition will allow AVTs to be used in lieu of portable testers for absence of voltage verification * VeriSafe is NOT rated to NFPA 70E. However, it is designed to be used in a way that allows the user to easily comply with the NPFA 70E requirements. 9 Panduit Corp. March 2016

NFPA 70E (proposed text for 2018 edition) Published in Second Draft Report, January 2017 120.5 Elements of Process for Establishing and Verifying an Electrically Safe Work Condition (7) Use an adequately rated portable test instrument to test each phase conductor or circuit part to verify it is de-energized. Test each phase conductor or circuit part both phase-to-phase and phase-to-ground. Before and after each test, determine that the test instrument is operating satisfactorily through verification on any known voltage source. Exception No. 1: An adequately rated permanently mounted test device shall be permitted to be used to verify the absence of voltage of the conductors or circuit parts at the work location, provided it meets the all following requirements: a) It is permanently mounted and installed in accordance with the manufacturer s instructions and tests the conductors and circuit parts at the point of work b) It is listed and labeled for the purpose of verifying the absence of voltage [UL 1436] c) It tests each phase conductor or circuit part both phase-to-phase and phase-toground d) The test device is verified as operating satisfactorily on any known voltage source before and after verifying the absence of voltage 10 Panduit Corp. March 2016

Key Features & Benefits Improved Safety & Risk Reduction Determine voltage status BEFORE equipment is accessed Prevents direct exposure to electrical hazards Increased Productivity Easy to use, initiate test with the push of a button No additional tools required Provides visual alert to abnormal power conditions Reliable Results Fail-safe design with active indications Safety functions meet SIL 3 per IEC 61508-1 Simplified Process for Easier Compliance Automated test sequence based on the steps in NFPA 70E for verification of an electrically safe work condition Automated test helps reduces operator errors Flexible Applications Designed for testing three-phase circuits up to 600V Install on line or load side of electrical disconnect Detects presence of AC and DC voltage 11 Panduit Corp. March 2016

Ideal Applications Equipment with a single source of incoming power High risk associated with access Frequently accessed equipment High incident energy Remote or difficult to access locations Outdoor, mezzanine, catwalk Sites with temporary or intermittent power Equipment with stored electrical energy VFDs, capacitors, etc. Equipment frequently serviced by third-party technicians or contractors 12 Panduit Corp. March 2016

VeriSafe Absence of Voltage Testers Reduce the risk of exposure to electrical hazards for improved worker safety Reduce testing procedure time and complexity to improve productivity Supports compliance when used as part of the lockout/tagout process described in NFPA 70E www.panduit.com/verisafe

Technical Specifications Applications Electrical System Voltage Detection Range Absence of Voltage Threshold For use in 1, 2, or 3-phase AC or DC systems Up to 600V AC (50/60 Hz) Up to 600 V DC 3 V Overvoltage Category III (600 V) Degree of Protection NEMA 1, 12, 4, 4X / IP 66 Short Circuit Current Rating 300,000 A rms symmetrical at 600 V Environment Operating Temperature Storage Temperature Humidity Pollution Degree 3 Battery Voltage Estimated Life 0 C to +60 C (32 F to 140 F) -45 C to +85 C (-49 F to +185 C) 5 to 95% non-condensing Industrial 3.6 V Lithium AA User replaceable. Estimate 5+ years with normal operating conditions. Standards UL 1436 Standard for outlet circuit testers and similar indicating devices. EN/CSA/UL 61010-1 Safety requirements for electrical equipment for measurement, control, and laboratory use. EN/CSA/UL 61010-2-030 Safety requirements for electrical equipment for measurement, control, and laboratory use Part 2-030: Particular requirements for testing and measuring circuits. UL 508 & CSA-C22.2 No. 14 Industrial control equipment. IEC 61508 Functional safety, SIL 3. FCC CFR 47 Part 15 Radio frequency devices. EN 61326 & EN 55011/CISPR 11 EMC standards for industrial measurement products. CAN ICES-1 Industrial, Scientific and Medical (ISM) radio frequency generators. Planned Certifications UL, cul, CE, RoHS 14 Panduit Corp. March 2016

Competitive Comparison Other Voltage Indicating Products Voltage Indicator Optical Indicator Voltage Test Station Panduit VeriSafe AVT External Footprint Voltage presence indicators Test for absence of voltage Absence of voltage indicator Verifies installation (confirmation tester is in direct contact with circuit) Safety functions meet IEC 61508 SIL 3 Requires additional tool No hazardous voltage on door Install without overcurrent protection UL 1436 Listing / NFPA 70E-2018 120.5 (7) 15 Cost Panduit $ Corp. March 2016 $$ $$$ $$