Log fired heating system

Similar documents
English. Heating with logs & wood pellets 20-40

Heating with pellets kw

Heating with log wood

HERZ ECO-Line Heating with logs or wood pellets

Heating with wood chips & pellets

English. Heating with logs & wood pellets 20-40

Heating with wood pellets kw

English. Efficiency. HERZ pellet boiler with condensing technology. ɳ over 106% COndEnSATiOn

Forward-looking and energy effi cient Biomass heating

Heating with wood chips

Product Range kw

HERZ biomass boilers 100 to 20,000 kw

Weishaupt WKmono 80. The next-generation burner for ratings up to kw. That s reliability

WOOD CHIP HEATING HPK-RA

This document is a preview generated by EVS

PE1 Pellet. PE1 Pellet. Pellet boiler - Canada. PE1 Pellet APPROVED FOR EPA 2020 EMISSION LIMITS.

PTG, SWT Series. Heat Recovery Systems

WOOD CHIP HEATING HPK-RA

PZ35RL BIOTECH THE FUTURE OF HEATING PZ 35 RL

Press Release. Short profile Beckhoff. Short profile February 2009 Page 1 of 6

High vacuum guide FOR PRE-SEPARATORS AND CYCLONES

CRA24-B3 controlled residential ventilation

Forum for European Electrical Domestic Safety FEEDS. Residential Electrical Safety How to ensure progress?

COMBIFAB F Fan The flexible fan for dust extraction systems in all industries

CHIMNEY SYSTEMS PRODUCT OVERVIEW. LAUNDRY CHUTES.

S3 Turbo Firewood boiler. S3 Turbo AVAILABLE WITH BROADBAND LAMBDA PROBE AND SERVO-MOTORS.

Porsche Classic Vehicle Tracking System FAQs

Detect. React. Benefit. Increase the availability of your plants with SIMATIC Notifier!

Forum for European Electrical Domestic Safety FEEDS. B. DOME FISUEL

COMPANY PROFILE.

Expansion vessel in a solar installation. White paper

The advantages of closed heating systems. White paper

Future development of the furniture industry A look at the next 3-5 years

AutoM Click to go to the page. AutoM Auto Shaker Filter

S3 Turbo Firewood boiler. S3 Turbo AVAILABLE WITH BROADBAND LAMBDA PROBE AND SERVO-MOTORS.

TWIN - GAS. Concentric flue gas system for decorative gas fires.

Biomass Pellet Boilers

Porsche Classic Vehicle Tracking System FAQs

The national standards bodies of:

This document is a preview generated by EVS

Textile fire protection closures EI 30/90

This document is a preview generated by EVS

This document is a preview generated by EVS

TopGas Wall Hung Condensing Gas Boiler

User friendly, compact, economical and safe

A WMIA Partner of the Year Winner S-Series Enclosureless Dust Collector

This document is a preview generated by EVS

english GUNTAMATIC BIoMAss BoIler HeATING range

This document is a preview generated by EVS

VICOTEC450 EXTRACTIVE VISIBILITY MEASURING DEVICES EXTRACTIVE VISIBILITY MEASUREMENT FOR INCREASED SAFETY IN TUNNELS

PRODUCT INFORMATION. GM901 Carbon Monoxide Gas Analyzers CO MEASUREMENT FOR EMISSION MONITORING AND PROCESS CONTROL. In-situ Gas Analyzers

This document is a preview generated by EVS

Beckhoff short profile

Combined boiler. for solid fuel and pellets

EUROPE STARTS WITH YOU!

ISO INTERNATIONAL STANDARD. Glass containers Vacuum lug finishes Part 1: General

Keeping European Consumers safe Rapid Alert System for dangerous non-food products 2014

National foreword. Text affected

English version. Alarm systems Terms and definitions

Accuracy counts! Sensors with analog output

This document is a preview generated by EVS

Air and dirt in closed systems

EN ISO 9001 ÖNORM. Quality management systems Requirements. Edition: EN ISO 9001: Cor.1: (consolidated version)

Stelrad Novello ECO radiator

ISO 7458 INTERNATIONAL STANDARD. Glass containers Internal pressure resistance Test methods

FINAL DRAFT FprEN


Sýnishorn Maintenance - Qualification of maintenance personnel

This document is a preview generated by EVS

Sludge, treated biowaste and soil Digestion of nitric acid soluble fractions of elements

ETA PE-K. The pellet boiler with technology that's built to last, for larger heating needs. 35 to 90 kw. A passion for perfection.

BIOMASS BOILER ATTACK PELLET 30 AUTOMATIC PLUS

Eurocode 9 Design of aluminium structures

This document is a preview generated by EVS

SOUTH AFRICAN NATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Steel cord conveyor belts Part 4: Vulcanized belt joints

UltraOil Condensing Oil Boiler

This document is a preview generated by EVS

Fire classification of construction products and building elements

This document is a preview generated by EVS

This document is a preview generated by EVS

This document is a preview generated by EVS

ISO INTERNATIONAL STANDARD. Adhesives for thermoplastic piping systems Part 1: Determination of film properties

This document is a preview generated by EVS

P4 Pellet. Pellet boiler. P4 Pellet.

Sýnishorn Health care services - Quality management systems - Requirements based on EN ISO 9001:2015

This document is a preview generated by EVS

KWB CLASSICFIRE Log-wood and pellet heating system 18/28 kw

HEXALOBULAR INTERNAL DRIVING FEATURE FOR BOLTS AND SCREWS (ISO 10664:2005) IRISH STANDARD I.S. EN ISO 10664:2005. Price Code

it500 Internet Thermostat INSTALLER MANUAL

Gas meters - Additional functionalities

P4 Pellet. Pellet boiler. P4 Pellet.

This document is a preview generated by EVS

This document is a preview generated by EVS

Sýnishorn General requirements for components used in drains and sewers

This document is a preview generated by EVS

This document is a preview generated by EVS

ELECTRICAL AND INSTRUMENTATION LOOP CHECK (IEC 62382:2006 (EQV)) IRISH STANDARD I.S. EN 62382:2007. Price Code

MKN Galley Solutions

This document is a preview generated by EVS

Transcription:

Log fired heating system De Luxe 18 De Luxe 20-40 Lambda 20-40

Competence is our success... HERZ FACTS: 22 companies Group headquarters in Austria Research & development in Austria Austrian owned 2,400 employees in more than 85 countries 24 production sites HERZ Armaturen GmbH The company Founded in 1896, Herz has been continuously active in the market for more than 118 years. With 9 sites within Austria, another 15 in Europe and more than 2,400 employees at home and abroad, HERZ Armaturen GmbH is the only Austrian manufacturer that produces equipment for the entire heating and installation industry and is one of the most important internationally. HERZ Energietechnik GmbH HERZ Energietechnik employs more than 230 staff in production and sales. At the company sites in Pinkafeld, Burgenland and Sebersdorf, Styria, there is state-of-the-art production as well as a research institute for new, innovative products. For a number of years, HERZ has worked with local research and training institutes. Over the years, HERZ has established itself as a specialist in renewable energy systems. HERZ places a great importance on modern, cost-effective and environmentally friendly heating systems with the highest level of convenience and user-friendliness. HERZ for the environment All HERZ biomass boilers fall below the strictest emission regulations. Numerous environmental endorsements bear witness to this. HERZ quality HERZ designers are in constant contact with recognised research institutes in order to improve the very high standards even further.

Convenient heating... Efficient and convenient heating using wood Simple, fast and user-friendly firing up without kindling. The very quiet running of the boiler is due to high quality system components. The large filling shaft for big logs guarantees a long burning time of up to 8 hours with a full load (depending on boiler-type). The greatest advantages of the HERZ firestar: Energy-saving combustion due to the unique double vortex combustion chamber Automatic cleaning of the heat exchanger - no work required Consistently high level of efficiency Simple removal of combustion & fly ash from the front no side cleaning apertures Low ash accumulation due to optimum combustion Innovative technology for the most natural fuel! Logs & wood briquettes heating with 50 cm logs! 3

Available models... De Luxe 18 De Luxe 20-40 Lambda 20-40 T-CONTROL firestar 18 De Luxe: Control unit BioControl 3000: burning control (lambda probe control) Buffer management Return flow temperature bypass (pump and mixer valve) 2 controlled heating circuits (pump and mixer valve) domestic hot water preparation frost protection Option for internal modular extensions for solar circuit control as well as other heating circuits (total maximum 6 heating circuits, for solar-use maximum 5 circuits). firestar 20-40 De Luxe: Control unit T-CONTROL: burning control (lambda probe control) Buffer management Return flow temperature bypass (pump and mixer valve) 1 controlled heating circuits (pump and mixer valve) domestic hot water preparation frost protection Simple screen design and convenient menu guide. Extension modules up to 55 modules possible (heating circuits, solar-use, second buffer etc.) firestar 20-40 Lamda: Control unit Lambda: burning control (lambda probe control) Buffer management Return flow temperature bypass (pump and mixer valve) Control of heating circuits, solar circuit control and domestic hot water preparation can be realised with external control units. 4

Easy, modern and comfortable T-CONTROL T-CONTROL De Luxe 20-40 Remote access to the controller using VNC Viewer As an additional option, the T-CONTROL offers the possibility for remote visualization and remote maintenance via smartphone, PC or tablet PC. The handling is the same as in the touch controller directly in the boiler. The processes and parameters can be read and modified any time from anywhere. Further advantages of the T-CONTROL: power-saving standby mode status and error messages via e-mail Data transfer and software updates via USB stick Possibility of Modbus-Communication easy and clear presentation of the functions from various components (hot water preparation pump, circulation pump, mixing valve, switchin valve, actuator-motors usw.) 5

Benefits and details... Different control options 11 7 4 Central control unit firestar BioControl 3000 (for firestar 18) Control unit firestar Lambda (for firestar 20/30/40) 1 For a detailed description of the different control options see page 4. Central T-CONTROL (for firestar 20/30/40) 2 Smoke extraction via open filling shaft door 3 6 To avoid smoke escaping when the filling shaft door is opened the ventilator sucks out the gases via the smoke extraction channel. Ensures a smoke free boiler room without interrupting the combustion process Highly efficient due to the double vortex combustion chamber The revolutionary double vortex combustion chamber ensures optimum blending of the combustion gases with oxygen. The flame is distributed across 2 chambers and therefore ensures highly efficient combustion. The combustion chamber consists of heat-resistant fireproof concrete (SiC) no sheet metal parts no wear and tear which means DURABILITY 6 10 1. Filling shaft door Simple firing using large 50 cm logs 2. Large firing up door Fast and simple firing up without kindling due to innovative technology 3. Cleaning door Simple removal of combustion and fly ash from the front

...of the HERZ firestar 18-40 9 8 Energy-saving combustion With built-in Lambda probe, which constantly monitors the flue gas values, the boiler responds to variations in fuel quality ensuring ideal combustion efficiency and the lowest emissions. The Lambda probe controls the primary and secondary air input, always achieving the cleanest combustion, even in partial load operation. 5 Sophisticated controls optimise flue gas temperature to maintain boiler performance. The results are lower fuel consumption and the lowest emission values even with varying fuel quality. 12 Automatic heat exchanger cleaning The heat exchanger surfaces are automatically cleaned by the integrated turbulators, even during heating operation. A high level of efficiency is maintained due to clean heat exchangers, resulting in low fuel consumption. The combustion and fly ash can simply be removed via the front using the integrated ash tray. No side cleaning apertures therefore less space is required. 4. Flue gas duct 5. Pipe heat exchangers with turbulators and automatic cleaning 6. Double vortex combustion chamber 7. BioControl 3000 controls central control unit 8. Lambda probe Automatic flue and combustion monitoring 9. Suction ventilator speed-controlled and monitored for the highest operational safety 10. Integrated ash tray simple cleaning via pull-out tray 11. Primary and secondary air flaps proportionally controlled separate air input 12. Efficient heat insulation for the lowest radiated heat loss 7

firestar with... In addition to its proven advantages, such as the unique double vortex combustion chamber, automatic heat exchanger cleaning, or smoke extraction via open filling shaft door, the log wood boiler firestar is also available with pellets flange. If the use of wood pellets is likely in the future, the log boiler with pellet flange is the perfect solution. If the buffer or heating circuits require heat after burning of all logs, the operation is automatically continued with pellets. firestar 20-40 De Luxe with pellet flange firestar 20-40 Lambda with pellet flange PLEASE NOTE: A pellet flange is possible for firestar 20/30/40 8

...pellet flange firestar with pellet flange combined with a pellet burner Heating with either logs or pellets Due to the separate combustion chambers, the operation can be switched easily between logs and pellets. Continued operation If the buffer or heating circuits require heat after burning of all logs, the operation is automatically continued with pellets. Selection of pellet discharge systems HERZ offers a variety of pellet discharge systems including flexible screw discharge, suction system or manual hand filling to suit different plant room layouts. The room discharge with a flexible screw is an easy and energy saving solution to empty the storage room in an efficient way. Room discharge with flexible screw from a bag silo. The bag silo can normally be placed into the boiler room (please pay attention to your local safety laws!). This solution is used if no separate storage room is available. Room discharge with a modular screw (in the storage room) and in combination with suction turbine. 9

A range for all requirements... With HERZ T-CONTROL and BioControl 3000 heating circuits, boiler, buffer and solar can be controlled centrally from the boiler. The control enables a range of application options. The 2 most common cases are shown below. Heating circuit 1 Heating circuit 2 Solar Hot water storage with solar usage and buffer storage: With this system configuration solar energy is utilised to provide the domestic hot water. When the solar input is insufficient to meet the hot water demand, additional heat is taken from the buffer tank. Additional heating circuits such as under floor heating and the radiators are supplied with heat from the buffer tank. Heating circuit 1 Heating circuit 2 Solar Solar heating support and hygienic hot water preparation: With this system configuration the solar energy heats the water in the buffer tank directly. Domestic hot water is provided using a heat exchanger. Additional heating circuits such as under floor heating and the radiators are supplied with heat from the buffer tank. HERZ buffer tank The installation of a buffer tank considerably increases the efficiency of the heating system, especially during periods of partial load. The variable heat loads from the different heating circuits (e.g. radiators and under floor heating) can be met readily from the buffer. A buffer tank is sized to store the energy of an the boiler s maximum heat output. HERZ recommends the following buffer tank sizes for the wood burning boiler: - firestar 18: minimum 1000 Liter (1500 Liter recommended) - firestar 20/30: minimum 2000 Liter - firestar 40: minimum 3000 Liter (Please note the relevant state regulations for buffer storage sizes in order to receive financial support!) HERZ service water storage HERZ offers the optimum solution for service water storage with or without solar register - according to the requirements of the customer. 10

firestar De Luxe BioControl 18 1250 (135 ) 1215 (90 ) Measurements & technical data... 1080 (45 ) 920 (0 ) firestar 18 firestar Lambda / De Luxe T-CONTROL firestar 20/30/40 firestar 18 20 30 40 Output range (kw) 7,6-18,0 9,9-22,0 9,9-30,0 9,9-40,0 Filling shaft contents (litres) 90 170 170 170 Dimensions (mm) A length - total 1385 1340 1340 1340 A1 length - casing 1080 1035 1035 1035 A2 length up to the end of the flue pipe 1210 1170 1170 1170 B width 620 670 670 670 C height 1365 1585 1585 1585 D flue pipe diameter 150 150 150 150 E filling shaft doors height 260 305 305 305 F filling shaft doors width 400 460 460 460 G flue pipe upper edge 1215 1450 1450 1450 (G) flue pipe - centre 1040 1275 1275 1275 H flow connection height 1145 1380 1380 1380 I return connection height 840 1065 1065 1065 J minimum clearance rear 600 600 600 600 K minimum clearance front 520 600 600 600 L filling / emptying connection height 135 135 135 135 We reserve the right to make technical changes. Technical data Boiler weight kg 519 622 622 622 Level of efficiency nıf % >93 >93 >93 >93 flue draft requirements (min./max.) mbar 0,05/0,20 0,05/0,20 0,05/0,20 0,05/0,20 maximum water pressure bar 3,0 3,0 3,0 3,0 maximum water temperature C 90 90 90 90 water capacity l 77 108 108 108 Electrical connection (V,Hz,A) / connection output (kw) 230,50,10/0,1 230,50,10/0,1 230,50,10/0,1 230,50,10/0,1 Emission values at full load Flue gas temperature C ~160 ~140 ~160 ~170 Flue gas mass flow rate kg/s 0,011 0,013 0,019 0,025 CO 2 conten Vol. % 15,54 15,4 15,4 15,6 Werte bei Teillast Flue gas temperature C ~100 ~100 ~100 ~100 Flue gas mass flow rate kg/s 0,005 0,0068 0,0068 0,0068 CO 2 conten Vol. % 13,9 13,9 13,9 13,9 Door hinge can be moved from RIGHT to LEFT as standard 1...Flow 1 internal thread 3...Safety heat exchanger 1/2 external thread 2...Return 1 internal thread 4...Filling / emptying connection 1/2 internal thread 11

BUISNESS PARTNERS IN: AUSTRIA BELGIUM BULGARIA CANADA CROATIA CZECH REPUBLIC DENMARK ESTONIA FINLAND FRANCE GREAT BRITAIN GREECE GERMANY HUNGARY IRELAND ITALY JAPAN LATVIA LITHUANIA LUXEMBOURG NETHERLANDS NORWAY POLAND PORTUGAL ROMANIA RUSSIA SERBIA SLOVAKIA SLOVENIA SOUTH AFRICA SPAIN SWEDEN SWITZERLAND UKRAINE www.grafikorange.com We reserve the right of errors, misprint, typographical failures and technical modifications! Data about our products are not guaranteed characteristics. Mentioned and illustrated discharge systems are system-dependent and only available as an option. In case of discrepancies between documents with regard to the scope of supply the information in the current offer is valid. All images are representations as a symbol and serve only to illustrate our products. Your partner: d06-2015 HERZ Energietechnik GmbH Herzstraße 1, 7423 Pinkafeld Österreich/Austria Tel.: +43(0)3357/42840-0 Fax: +43(0)3357/42840-190 Mail: office-energie@herz.eu Internet: www.herz.eu HERZ Armaturen GmbH Fabrikstraße 76, 71522 Backnang Deutschland/Germany Tel.: +49(0)7191/9021-0 Fax: +49(0)7191/9021-79 Mail: zentrale-bk@herz.eu Internet: www.herz.eu HERZ biomass boilers exceed the strictest emission regulations.