PREMIER PLATINUM INFRARED GAS SENSOR

Similar documents
LOW POWER VERSION DUAL HYDROCARBONS AND CARBON DIOXIDE SENSOR Exd Certified VERSIONS *** Available in EN50271 / SIL1 Certified versions ***

Technical data sheet TDS0034

PREMIER PLATINUM INFRARED TRIPLE RANGE HYDROCARBON SENSOR Exd Certified versions *** Available in EN50271 / SIL1 Certified versions ***

Technical data sheet TDS0060

CO2 Carbon Dioxide Sensor

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining

IR15TT-R Miniature Infrared Gas Sensor for Monitoring Carbon Dioxide and Methane up to 100% Vol.

IR25 Dual Gas Series Datasheet

IR15 Dual Gas Series Datasheet

Key Features. General Description

IR1 Single Gas Series Datasheet

IR15TT-R Miniature Infrared Gas Sensor for Monitoring Carbon Dioxide and Methane up to 100% Vol.

Lamp Supply (Recommended)

Integrated IR Datasheet

IRceL CH4 Methane (CH 4

ALTAIR 5X Multigas Detector Product Specification

VQ500 Series Combustible Gas Detector Elements

MICROpeL 75 Combustible Gas Sensor Part Number: PM

4P75 CiTipeL Combustible Gas Sensor Part Number: PM

4P-90 CiTipeL Combustible Gas Sensor Part Number: PM

P R O D U C T D ATA S H E E T

PrimaX IR Gas Transmitter Designed for Reliable Performance in Extreme Conditions

ULTIMA X5000. MSAX5000.com

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

4) Intrinsic Safety Certification

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

Dräger X-am 2500 Multi-Gas Detection

Model D12-IR. Digital Gas Transmitter...

S5000 Gas Monitor. GMS5000.com

GG-LEL2 COMBUSTIBLE GAS SENSOR. Installation and Operation Manual

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

GasAlertMicroClip X3 Specifications

SIMRAD GD10 IR GAS DETECTOR

SIMRAD GD10PE IR GAS DETECTOR

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

Hydrocarbon Gas Detector

Dräger Pac Ex 2. Elegant and smart... Explosive hazards and lack or surplus of oxygen under control

Dräger PIR 3000 Detection of flammable gases and vapours

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

TX6351 TX6352 Sentro 1 Universal Gas Detector Contents

ESD3000IR ESD3000IR. Infrared Gas Detector

Dräger Polytron Pulsar 2 Open Path Gas Detector

Safe Operation Manual. Honeywell IQ Force Gas Detector

Pac Ex 2. Elegant and smart Explosive hazards and lack or surplus of oxygen under control

GX-2009 Portable Gas Monitor Operator s Manual

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

DESIGN MANUAL MODEL GIR900 INFRARED COMBUSTIBLE GAS SENSOR

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

G-TECTA TM. Portable Gas Detection Instruments

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.

GAS PLUS ALARM SYSTEM

SIMRAD GD10P - IR GAS DETECTOR OPERATING MANUAL

FIS SMART SENSOR U (Draft 1) June 25, 2001

SprintIR -W CO2 Sensor

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

CO warning instruments and gas spillage detectors

SEC Signature Process Gas Analyzer

Dräger X-am 5000 Multi-Gas Detection

Operation and Maintenance Manual

Leak detector for refrigerant gases R22, R134a, R410A, R407C...

Dräger Polytron 8000 Stationary gas detector (EC)

Xgard. Fixed detectors For flammable, toxic or oxygen gases

Dräger PIR 7000 Flammable Gas Detection

INSTRUCTION & SERVICE MANUAL

Gas cylinder scale Model GCS-1

T.ex Single Gas Detector VISA

APPLICATION DATA SHEET

ESD3000 ESD200 Combustible / Toxic Gas Detector

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Dräger X-am 5000 Multi-Gas Detection

Datasheet: K-22 LO Sensor

testo 316-EX gas leak detector Instruction manual

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS

SEC Millenium Hydrocarbon Gas Detector

REGARD. REGARD 4-20 AND Ex CHANNEL CARDS INSTALLATION AND OPERATING MANUAL (FOR ATEX VERSION CARDS)

ESD500. ESD500 Combustible / Toxic Gas Detector

SIL 2. Ultima X Series Gas Monitors CERTIFIED

INSTRUCTION MANUAL (ATEX / IECEx)

APPLICATION DATA SHEET

ALTAIR 5X Multigas Detector

Polytector III G999 for Ex zone 0

Model GX Operator s Manual

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

Dräger X-am 7000 Multi-Gas Detection

VQ600 Datasheet. Pellistor Gas Sensor for Hazardous Areas (Fixed Systems) FEATURES TECHNICAL SPECIFICATION OPERATION

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

TraceNet ECM Series Control System

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

INSTRUCTION MANUAL (ATEX / IECEx)

GMA 301. Operation Manual. Worldwide Supplier of Safety Solutions. Part Number

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

1.1 Definitions of alert icons. For your safety

Dräger Polytron SE Ex Fixed Gas Detector

02/11/2015

Transcription:

PREMIER PLATINUM INFRARED GAS SENSOR LOW POWER VERSION DUAL HYDROCARBONS AND CARBON DIOXIDE SENSOR Exd Certified VERSIONS *** Available in EN50271 / SIL1 Certified versions *** Technical data sheet TDS0150 SIL1 Non - SIL MSH-LDS/HC/HCO2 MSHia-LDS/HC/HCO2 MSH-LD/HC/HCO2 MSHia-LD/HC/HCO2 Use 80% less power than the other product ranges, whilst delivering two independent gas sensor channels Equivalent current per sensor channel of only 7.5mA Drop-in replacement No loss of performance Uses the same well established technology FEATURES Combines all the features of the hydrocarbon and carbon dioxide Premier sensors, enabling the measurement of two different gases with one sensor. No increase in physical size or power consumption when compared with a single gas Premier sensor. Ideal for portable, battery powered instruments. Contains all the necessary optics, electronics and firmware to provide THREE linearised, temperaturecompensated measurements: Methane, propane and carbon dioxide. Digital output for direct interface to host circuitry. The hydrocarbon channel can be used to measure methane from 0 to 100% volume with an autoranging feature that provides the optimum resolution in both the % LEL range and the % volume range. Has equal performance to a 0-5% volume methane sensor AND a 0-100% volume methane sensor. The storage of multiple calibration, temperature compensation and linearisation data enables simultaneous readings from the hydrocarbon channel for high resolution methane AND a 0-2% volume propane range. All sensor types are user configurable using configuration equipment available from Dynament. Enhanced EMC protection. Internal Flash memory allowing sensor firmware updates via configuration equipment. Dynament Limited Premier House ٠The Village ٠South Normanton ٠Derbyshire ٠DE55 2DS ٠UK. Tel: 44 (0)1773 864580 ٠ Fax: 44 (0)1773 864599 email: sales@dynament.com ٠ www.dynament.com TDS 0150 Issue 1.0 09/7/14 Change N/A Page 1 of 12

DESCRIPTION Dynament infrared sensors operate by using the NDIR principle to monitor the presence of target gas. The sensor contains a long life tungsten filament infrared light source, an optical cavity into which gas diffuses, temperature compensated pyroelectric infrared detectors, an integral semiconductor temperature sensor and electronics to process the signals from the pyroelectric detector. The sensor uses a digital output for direct communications with instrument electronics. The digital output is a UART format comprising 8 data bits, 1 stop bit and no parity. Refer to specification for available baud rates. Patent Protection The sensor design is protected by the following Patents Great Britain GB 2 401 432 & GB 2 403 291 Europe EP 1544603 & EP 1818667-Pending France EP [ FR ] 1544603 Germany EP [ DE ] 1544603 Italy EP [ I ] I1544603 Switzerland EP [ CH ]1544603 USA 7, 244, 939 Other World Patents Pending Hydrocarbon Response Characteristics The Premier range of hydrocarbon infrared gas sensors are calibrated to provide an output signal linearised for a specific gas type and concentration during manufacture. However, the sensor will also respond to a range of other hydrocarbon gases. The following graphs show the relative response of a methane sensor, and a propane sensor, to some of the common hydrocarbons. These characteristics can be used as a guide to setting up the associated instrument alarm levels. 5.00 Premier methane sensor cross sensitivity Reading on methane scale % volume 4.50 4.00 3.50 3.00 2.50 2.00 1.50 1.00 0.50 M ethane Ethane Propane Butane Pentane Hexane Ethylene Ethanol Propylene Cyclopentane 0.00 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 Applied gas % volume TDS 0150 Issue 1.0 09/7/14 Change N/A Page 2 of 12

Premier propane sensor cross sensitivity Reading on propane scale, % volume 2.50 2.25 2.00 1.75 1.50 1.25 1.00 0.75 0.50 0.25 Butane Pentane Ethane Propane Ethylene Ethanol Hexane Propylene Cyclo pentane M ethane 0.00 0.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 Applied gas % volume Note Refer to data sheet TDS0050 for additional cross reference data Hydrocarbon Temperature Compensation The Premier sensor is temperature compensated over the range of -20 C to +50 C. The output variation is ± 2% FSD or ± 10% of the reading up to 50% FSD and ± 15% of the reading from 50% to 100% FSD, which ever is greater. The following graph is based on the hydrocarbon sensor being characterised for methane. Premier sensor temperature compensation -20 C to + 50 C 5.0 Gas reading 4.5 4.0 3.5 3.0 2.5 2.0 1.5 1.0 Ideal reading Min limits Max limits 0.5 0.0 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 Applied gas TDS 0150 Issue 1.0 09/7/14 Change N/A Page 3 of 12

Hydrocarbon Linearity The Premier sensor linearity at ambient temperature is ± 2% FSD or ± 10% of the reading which ever is greater. The following graph is based on the hydrocarbon sensor being characterised for methane, data based on 24 sensors. Premier sensor CH4 linearity Gas readings 5.0 4.5 4.0 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0.0 Min reading Max reading Min limits Max limits 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 Applied gas %v/v Carbon dioxide Temperature Compensation The Premier sensor is temperature compensated over the range of -20 C to +50 C. The output variation is ± 0.1% v/v or ± 10% of the reading up to 50% FSD and ± 15% of the reading from 50% to 100% FSD, which ever is greater. Gas reading % volume CO2 100 90 80 70 60 50 40 30 20 10 0 Premier sensor temperature compensation -20 C to + 50 C Ideal reading Min limits Max limits 0 10 20 30 40 50 60 70 80 90 100 Applied gas % volume CO2 TDS 0150 Issue 1.0 09/7/14 Change N/A Page 4 of 12

Carbon dioxide Linearity The Premier sensor linearity at ambient temperature is ± 2% FSD or ± 10% of the reading which ever is greater. The following graph is based on the 0-5% v/v sensor, data for 24 sensors. 100 90 Premier HCO2 linearity Gas reading % volume CO2 80 70 60 50 40 30 20 10 0 M in. reading M ax. reading M in limit Max limit 0 10 20 30 40 50 60 70 80 90 100 Applied gas % volume CO2 TDS 0150 Issue 1.0 09/7/14 Change N/A Page 5 of 12

Calibration options Dynament recommend a maximum interval of 12 months between calibration checks. A small amount of zero drift can be accomodated by re-zeroing the gas detector against the sensor. The degree of drift that is acceptable should be determined by the user. Note that the subsequent change in gas reading will be greater than the change in zero reading. The Dual Gas sensor has four ranges in all. Range 1 0-5% volume methane Range 2 0-100% volume methane Range 3 0-2% volume propane Range 4 0-100% volume carbon dioxide If the sensor requires either a Zero or Span adjustment, there are two methods that can be used: 1) By using the Premier Configuration Unit When used in conjunction with dedicated PC software, this device uses the data communication pins on the sensor to provide a means of calibration. 2) By using the data communications pins and software written in accordance with the protocol supplied by Dynament. Gas calibration is best carried out at 50% for both ranges when used in the biogas mode and at 100% when used as individual gas measurements. If the calibration gas level is entered incorrectly for any range, there will be an error in the calibration. It is the user s responsibility to ensure that the calibration procedure is correctly applied. Checks on the correct calibration gas level that are used during span operations should be implemented within the calibration routine of the host gas detector s firmware. Note: a zero calibration must always be carried out before a span calibration. Calibrate each gas type individually do not use a mixture of CH4 and CO2 in the same cylinder Sensor warm-up time When power is first applied to the sensor, the voltage at the output pin is held at a pre-determined level. The default setting for this start-up value is the zero gas value. This condition is maintained for a default warm-up time of 45 seconds, after this time the output voltage represents the calculated gas value. Sensors can take up to 1 minute to indicate the correct gas reading. Note: the sensor can calculate any reading from -100% FSD to +200% FSD in the first minute. The output value that is read using the communications pins is always held at -250% FSD during the warm-up time. The duration of the warm-up time can be pre-programmed to alternative values at the time of ordering sensors, the range being 45 to 120 seconds. Temperature transients and gas flow rates. The Premier sensor employs a pyroelectric detector, the output from which can be disrupted by sudden changes in temperature. If there is an excessive change in the ambient temperature, gas sample temperature or flow rate, then the output signal will be momentarily frozen. Correct operation is restored when the effects of the transient have settled. Rates of change in the ambient temperature should be restricted to 2 C/minute and gas flow rates kept below 600 cc/minute. TDS 0150 Issue 1.0 09/7/14 Change N/A Page 6 of 12

Power supply considerations The sensor power supply rise time must be less than 50 ms to ensure correct operation. Operation outside the range of 3 5 V dc will result in either fault indication, or the sensor will not function correctly. The current consumption varies during the program cycle at a rate of 2Hz. The peak current is 36mA, the current whilst the infrared source is powered is 20mA and the current whilst the source is turned off is 7mA. The average current with a 3V power supply is 15mA. Current peak 36 ma 20 ma 7 ma Current waveform for Premier low power sensor. TDS 0150 Issue 1.0 09/7/14 Change N/A Page 7 of 12

Sensor over-range condition The sensor will continue to provide an output up to a pre-determined percentage of the full scale value; at this point the reading is clamped, regardless of any further increase in detected gas level. The over-range value should be specified when ordering; choose from the following values 100%, 125%, 150% and 200% The linearity of the output is only guaranteed up to the full scale for the sensor; the over-range condition for the host instrument should therefore be determined by the user. Sensor fault indication The sensor constantly performs checks on the internal memory contents, the incoming supply voltage and the analogue signal values. These checks are used to ensure that the sensor is operating within its correct parameters, and that no internal faults have developed. If a fault condition is detected, the output reading is set to the -250% full scale value. Digital interface The digital communication pins RX and TX operate at a 2.8V logic level. When interfacing to external circuitry that uses a higher voltage level it is necessary to limit the current that can flow. The external voltage level should be 5V maximum and a 3K3 resistor should be used in series with each communication pin. The Rx and Tx voltage limits are as follows: RX - VIH: Input High minimum voltage - 0.8 VDD = 2.24V RX - VIL: Input Low maximum voltage - 0.2 VDD = 0.56V TX - VOH: Output High minimum voltage - VDD - 0.7 = 2.1 TX - VOL: Output Low maximum voltage - 0.6V Refer to tds0045 Communication Protocol for further details. Contact Dynament Ltd. to obtain the document. TDS 0150 Issue 1.0 09/7/14 Change N/A Page 8 of 12

CERTIFICATION DETAILS European ATEX Certification Approval body Sensor types MSH-DP, MSH-LDS SIRA Sensor types MSHia-DP, MSHia-LDS Certificate Number Test Standards Certification Codes Input parameters Operating temperature SIRA 04ATEX1357U EN60079-0:2009, EN60079-1:2007, EN60079-11:2007, EN60079-26:2007 I M2 Ex d I Mb II 2 G Ex d IIC Gb 0.8W max, 30V max. (See footnote) -20 C to +60 C (See footnote) I M1 Ex d+ia I Ma II 2 G Ex d IIC Gb Ui=6V dc, Pi=0.8W (See footnote) International IECEx Certification Sensor types MSH-DP, MSH-LDS Sensor types MSHia-DP, MSHia-LDS Approval body SIRA Certificate Number IECEx SIR 05.0053U Test Standards Certification Codes IEC 60079-0:2007-10, Edition 5 IEC60079-1:2007-4, Edition 6 EN60079-26:2006 Edition 2 Ma Ex d+ia I and/or Ex d I and/or Ex d IIC Gb Ex d IIC Input parameters 0.8W max, 30V max. Ui=6V dc, Pi=0.8W Operating temperature -20 C to +60 C (See footnote) North American Certification Sensor type MSH-LDP Sensor type MSHia-LDP Approval body Underwriters Laboratory Inc. Underwriters Laboratory Inc. File Reference E336365 E336365 Test Standards UL 60079 0, 4 th Edition UL 60079-1, 6 th Edition CAN/CSA-C22.2 No. 60079-0-1-7 CAN/CSA-C22.2 No. 60079-1 part 1, 1 st Edition UL913 7 th, Edition UL 60079 0, 4 th, Edition UL 60079 11, 2 nd, Edition CAN/CSA-C22.2 No. 157-92 Hazardous Locations Class 1, Zone 1, AEx d IIC and Ex d IIC Hazardous Locations Class I, II, III, Division 1 Class 1, Zone 0, AEx ia IIC, T4 with 60 C ambient Input/Entity parameters 0.8W max, 30V max. Ui=6V dc, Pi=0.8W, Ci=4.105µF, Li=0 mh Input parameters are defined for certification purposes only, refer to the Specification table for the sensor operating voltage and temperature range. TDS 0150 Issue 1.0 09/7/14 Change N/A Page 9 of 12

Operating Voltage Range: GENERAL SPECIFICATION 3.0 5.0 V d.c. Operating Current: Average current 15mA. See graph on page 7 Operating temperature range: -20 C to +50 C (-4 F to 122 F) Warm up time: To final zero ± 2% of full scale: 1 minute @ 20 C (68 F) ambient Storage temperature range: -20 C to +50 C (-4 F to 122 F) Humidity range: 0 to 95% RH non-condensing. Digital signal format: 8 data bits, 1 stop bit, no parity. 2.8V logic level Standard baud rates: 38,400, 19,200, 9600, 4800 User configurable parameters: Full-scale value, resolution, Sensor zero function Sensor span function MTBF: > 5 years Weight : 15 grams Pressure ± 5% of the calibration pressure to maintain the accuracy limits HYDROCARBON CHANNEL SPECIFICATION Methane measuring range: Hydrocarbon measuring range Resolution: Accuracy: Response Time T 90 : Zero Repeatability: Span Repeatability: Long term zero drift: Temperature performance: * May not be applicable when using gas cross-reference factors User configurable parameters and functions: 0-5%, 0-100% volume or both 0-100% LEL equivalent 0.01% for readings up to 5% volume methane 0.1% for readings from 5% up to 100% volume methane 0.01% propane for all readings ± 10% of the reading @ 20 C (68 F), 1 bar pressure, applied gas. <30s @ 20 C (68 F) ambient ± 1% of full scale @ 20 C (68 F) ambient ± 2% of full scale @ 20 C (68 F) ambient ± 1% of full scale per month @20 C (68 F) ambient, (max ± 3% of full scale per year) ± 0.1% volume or ± 10% of reading up to 50% of full scale, ± 15% of reading from 50% to 100% of full scale, or 2% of full scale whichever is greater over the range -20 C to +50 C (-4 F to 122 F) Zensor zero function Sensor span function Over-range value CARBON DIOXIDE CHANNEL SPECIFICATION Measuring ranges: 0-100% volume CO 2 Resolution: 0.1% Accuracy: ± 10% of the reading @ 20 C (68 F), 1 bar pressure, applied gas. Response Time T 90 : <30s @ 20 C (68 F) ambient Zero Repeatability: ± 1% of full scale @ 20 C (68 F) ambient Span Repeatability: ± 2% of full scale @ 20 C (68 F) ambient Long term zero drift: ± 1% of full scale per month @20 C (68 F) ambient, (max ± 3% of full scale per year) Operating temperature range: -20 C to +50 C (-4 F to 122 F) ± 10% of reading up to 50% of full scale and ± 15% of reading Temperature performance: from 50% to 100% of full scale over the range -20 C to +50 C (-4 F to 122 F) TDS 0150 Issue 1.0 09/7/14 Change N/A Page 10 of 12

+ ve supply, see notes 3.38 Tx 0.43 Rx MECHANICAL DETAIL - ve supply, see notes 5.08 10.67 4.8 +0.5/-0.0 16.6-0/+0.2 20 Dia. 15mm Dia 20mm NOTES 1. TOLERANCE: +/- 0.15 UNLESS OTHERWISE STATED. 2. RECOMMENDED PCB SOCKET WEARNES CAMBION LTD CODE: 450-3326-01-06-00. 3. USE ANTI-STATIC PRECAUTIONS WHEN HANDLING 4. DO NOT CUT PINS 5. DO NOT SOLDER DIRECTLY TO PINS 6. THE LABELLING ADDS UP TO 0.2 TO THE OUTER DIAMETER, AND UP TO 0.2 TO THE OVERALL HEIGHT All dimensions are in millimetres. Pins viewed from underside Diameter of pins = 1.5 +/- 0.05 Tx & Rx communication connections are available as either pads or pins NOTE The above pin configuration is shown for the POSITIVE version of the sensor. The NEGATIVE version has the +ve and ve supply pin positions exchanged. See ordering details. Warranty information All Dynament Premier sensors carry a five year warranty against defects in materials and workmanship. The warranty is invalidated if the sensors are used under conditions other than those specified in this data sheet. Particular attention should be paid to the following criteria: Observe the correct supply polarity Do not exceed the maximum rated supply voltage of 5V Do not solder directly to the sensor pins Do not expose the sensor to corrosive gases such as hydrogen sulphide Do not allow condensation to take place within the sensor Dynament reserve the right to alter technical specifications, without prior notice, when it is appropriate to implement a technical enhancement that leads to improved performance. Should any changes be required that could affect the customer s use of the product, Dynament will endeavour to contact customers directly to inform them of the changes. TDS 0150 Issue 1.0 09/7/14 Change N/A Page 11 of 12

Ordering Details In order to completely specify the type of sensor that is required, the customer needs to provide the following information:- An Order Code (see below) that specifies the sensors basic physical and electrical characteristics. The sensor configuration requirements. EXAMPLE OF ORDER CODES MSH LDS / HC / HCO2 / P / F Option FILTER : BLANK = OMITTED F = FITTED SUPPLY POLARITY : P = Positive N = Negative GAS TYPES : HC = Hydrocarbon HCO2 = High Range Carbon dioxide LOW POWER DUAL SENSOR DP = Non SIL DS = SIL1 TYPE MSH or MSHia (For Mining M1 applications only) CONFIGURATION OPTIONS (To be stated on customer order in addition to the Order Code) 1. Communication speed 38,400 baud (default), specify alternative rate if required. 2. Over-range value: 100%, 125%, 150% and 200% of full-scale value. TDS 0150 Issue 1.0 09/7/14 Change N/A Page 12 of 12