Searchpoint Optima Plus

Technical Summary. Searchpoint Optima Plus Specification. Output ma sink or source, (Default current source) 0-4 ma (Default 4 ma)

Searchline Excel. The Searchline Excel is the World s best selling infrared open path gas detector

SPM Flex Chemcassette Tape-Based Gas Detector

Application Note. Comparison of optical detection systems for Infrared (IR) Hydrocarbon gas detection

MeshGuard and MeshGuard Gamma

Honeywell Analytics. Order List BW Clip & IntelliDoX

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

Sensepoint XCD RTD. A gas transmitter for use with directly or remotely mounted toxic and Oxygen gas sensors

Searchline Excel. The Searchline Excel is the World s best selling infrared open path gas detector

Signalpoint. The Signalpoint range of flammable, toxic and Oxygen gas detectors offer users a low cost solution to their indoor gas monitoring needs

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

MeshGuard and MeshGuard Gamma

Honeywell Analytics is pleased to announce the release of Version firmware software for the SPM Flex TM product line.

XNX Universal Transmitter

Searchline Excel. The Searchline Excel is the World s best selling infrared open path gas detector

Unipoint Controller. The Unipoint, a simple DIN rail mounted controller

XNX Universal Transmitter

Touchpoint Pro Flexible Gas Control System

Operating Instructions

Gas Detection. Touchpoint Plus. A whole new control experience

Sensepoint. The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a low cost solution to their gas monitoring needs.

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Operating Instructions

Safety Manual. XNX TM Universal Transmitter. Table of Contents SIL 2 Certificates Overview Safety Parameters

Sieger Apex. Flexibility that meets your requirements

Sieger fixed gas detection. Fixed protection from hazardous gas

Sensepoint XCL. Gas Detection. Fixed Gas Detector FEATURES & BENEFITS. Flexible Output Options. Visual Integration. Faster Installation

Sensepoint XCL Fixed Gas Detector

Touchpoint 4. The Touchpoint 4 controller provides protection of personnel and plant from flammable, toxic and Oxygen gas hazards

Unipoint controller. The Unipoint, a simple DIN rail mounted controller

Dräger PIR 3000 Detection of flammable gases and vapours

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Installation Guide and Operating Manual MAN0932_V1_ _Rev B_08-12

Touchpoint Plus. A whole new control experience

Introducing gas detection so intelligent, it s as close to 100% prevention as you can get

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Life Safety Network. Intelligent solutions for advanced requirements

System 57. An advanced World of intelligent gas detection system management

Sensepoint XCD. Flammable, toxic and oxygen. catalytic, electrochemical cell and infrared sensors.

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Operating Instructions and Maintenance Manual

PrimaX IR Gas Transmitter Designed for Reliable Performance in Extreme Conditions

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

XNX Universal Transmitter

Technical Manual. LeakFilm 5. 5 Channel Conductive Liquid Leak Detection Controller

SafEye OPEN-PATH GAS DETECTION SYSTEM XENON 700. We INVENTED it... We PERFECTED it! Patent No. US 5,281,816; US 6,061,141; EP

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Series 3000 XPIS. 2-wire loop powered toxic and Oxygen gas detector for use in potentially explosive atmospheres

Dräger Polytron 8720 IR Detection of carbon dioxide

PROTECTION THAT MAKES SENSE Bluetooth Enabled Gas Detector

SAFEYE XENON 700. Hydrocarbons and ethylene detection. Heated optics. 10-year Warranty for the Xenon flash bulb. SIL 2 according to IEC 61508

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Dräger PIR 7000 Flammable Gas Detection

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Gas Detection. MeshGuard RAE Systems by Honeywell Battery-Powered Wireless Gas Detector

Dräger Polytron Pulsar 2 Open Path Gas Detector

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Dräger Polytron 8200 Stationary gas detector (CatEx)

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Touchpoint 1. The Touchpoint 1 controller provides 24 hour protection from flammable, toxic or Oxygen gas hazards.

XNX Universal Transmitter. A universal transmitter compatible with all Honeywell Analytics gas sensor technologies DRAFT

SIL 2. Ultima X Series Gas Monitors CERTIFIED

Sensepoint XCD RTD. Remotely monitor toxic gases in Class 1, Div 2 areas while reducing the maintenance, training and overall cost of gas monitoring

Zareba Sensepoint Pro

Dräger GS01 (wireless) Detection of flammable gases and vapours

Metro Gas Detector. The Metro addressable gas detector enables remote monitoring of flammable and toxic gas hazards

The SharpEye 40/40I (IR3) Flame Detection

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Sensepoint XCD. Flammable, toxic and oxygen deficiency gas detector using catalytic, electrochemical cell and infrared sensors.

Dräger Polytron 5720 IR Toxic Gas Detection

Dräger Flame 2500 Flame Detection

Dräger Flame 2100 Flame Detection

Touchpoint Plus. A whole new control experience

System 57. An advanced world of intelligent gas detection system management

The SharpEye 40/40M (Multi IR) Flame Detection

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

S5000 Gas Monitor. GMS5000.com

EC FX NH3 SECONDARY HEADLINE. A new and improved approach to ammonia gas detection

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

Dependable Solutions for Gas Detection

Dräger Polytron 8310 Stationary gas detector (DSIR)

The SharpEye 40/40L4-L4B (UV/IR) Flame Detection

Dräger Polytron 5720 IR Detection of carbon dioxide

GS01 (wireless) Detection of flammable gases and vapours

Ordering Information. Ordering Information. Transmitter S3KUX S3KAX

APN0064.P65 Issue 01-06/2000 COMPARISON OF OPTICAL DETECTION SYSTEMS FOR INFRARED HYDROCARBON GAS DETECTION

Technical Manual. LeakFilm Pro. Single Channel Conductive and Chemical Liquid Leak Detection Controller with Leak Location Detection

Dräger PIR 7200 Detection of toxic gases and oxygen

Gas Detection. ConneXt Loneworker Real-time visibility on the safety, location and productivity of your isolated workers

Hazardous Locations Demand Superior Gas Detection! Quasar 900 provides the most reliable gas detection in all weather conditions!

The SharpEye 40/40R (IR) Flame Detection

OLC(T) 100 FIXED GAS DETECTOR

EC FX NH3. A new and improved approach to ammonia gas detection

Danfoss gas detection unit Type GD Heavy Duty

The SharpEye 40/40I (IR3) Flame Detection

ULTIMA X5000. MSAX5000.com

Transcription:

Searchpoint Optima Plus Advanced infrared point gas detector

Searchpoint Optima Plus Why Infrared? Failsafe operation Fast speed of response Reduced routine maintenance Immune to catalytic poisons Long operating life Works in inert atmospheres Why Searchpoint Optima Plus is the right choice... Experience gained from over 100,000 units installed worldwide Improved reliability Optional HART over output Can detect a wide range of hydrocarbon gases including solvents Increased reliability with no moving parts Increased stability from self compensating optics Immune to long term component drift Remote functional gas test facility Certified for North American and European Hazardous areas Increased false alarm rejection Increased uptime with contaminated optics warning Dynamic Heating Control ensures condensation free optics No undetected failures Improved diagnostics Integral event logging Reduced power consumption Certified to many hazardous area classification schemes including: European (ATEX), UL, CSA, IECEx and more Market leading point infrared Hydrocarbon gas detector offering proven performance and sensitivity With over 40 years experience in the design, manufacture, installation and maintenance of point infrared gas detection, currently has a Worldwide installed base of over 100,000 infrared point Hydrocarbon gas detectors in a wide spectrum of applications from light industrial to the most demanding of offshore petrochemical environments. Searchpoint Optima Plus is an infrared point Hydrocarbon gas detector certified for use in potentially explosive atmospheres. The unit s infrared detection principle offers the fastest speed of response and fail-to-safe operation, ensuring that your plant is compliant, your personnel are protected and your production process can deliver maximum uptime. Reduced routine maintenance, when compared with conventional electro-catalytic based gas detectors, provides low ongoing cost of ownership. The development of advanced internal fault diagnostics and false alarm rejection algorithms ensures that Searchpoint Optima Plus delivers the highest level of operational integrity. Typical applications include environments that may suffer from the presence of catalytic bead poisons or inhibitors, or where there are harsh environmental conditions forcing increased time between routine maintenance, for example; offshore oil and gas platforms, floating production storage and offloading (FPSO) vessels, tankers, onshore oil and gas terminals, refineries, LNG / LPG bottling plants, gas compressor / metering stations, gas turbine power plants, refineries, solvent printing and coating plants. Over 100 gas and vapour calibrations are available. For a list of detectable gases and vapours, please contact our Customer Support team or your local distributor.

Failsafe Hydrocarbon Gas Detection 1. Optics Block The 4-channel (dual compensated) optics-block is the heart of the Searchpoint Optima Plus. It is specifically designed to compensate for changes in the external environment similar to 2-channel designs, but also compensates for long term component drift such as infrared sources and detectors. This provides the Searchpoint Optima Plus with the most stable optics design possible. 2. Microprocessor The microprocessor controls the operation of the Searchpoint Optima Plus. The signal processing and algorithms provide a new dimension in false alarm rejection delivering the highest level of operational integrity. 3. Heated Optics Plus Dynamic Heating Control Heated optic components, monitored via smart electronics, eliminate condensation build up with power saving features. 4. Remote Gassing Cell Factory fitting of this optional gassing cell within the optical path allows the remote injection of functional test gas to validate the performance of a Searchpoint Optima Plus. Remote Gas Sampling Systems For monitoring remote or inaccessible locations Searchpoint Optima Plus can be fitted with a flow housing and engineered into a gas sampling system. Single-point and multi-point systems are available for both hazardous and non-hazardous areas. 1. 4. 2. 3. Sunshade / Deluge Protection This multi-purpose accessory supplied as standard shields Searchpoint Optima Plus from the extremes of operational environments ensuring reliable operation. Storm Baffle This optional baffle reduces wind chill, salt and dust build-up in exposed applications subjected to high wind speeds e.g. Offshore HVAC intakes and FPSO turrets etc. Standard Weather Protection This accessory supplied as standard, offers the best compromise between water / dust ingress and speed of response. XNX Universal Transmitter This device offers a local display and non-intrusive access via a magnetic switch. It has a HART communications output and optional Modbus, Foundation Fieldbus or relays. HALO Junction Box This is an Ex e certified junction box, with an LED light ring to provide a local visual status indication, and an optional non-intrusive HART interface. Dust Barrier This barrier fitted inside the standard weather protection provides additional protection against the ingress of dust and contamination entering the optical path. Gassing Cover The gassing cover enables confidence checking of the Searchpoint Optima Plus. It provides a close fit onto the standard weather protection and can be installed without the use of any special tools. Calibration Cap The calibration cap is required to achieve accurate calibration of the Searchpoint Optima Plus. Other Accessories Duct Mounting Kit This mounting plate arrangement enables installation of Searchpoint Optima Plus with a duct/ventilation system. It enables functional gas testing without removing the Searchpoint Optima Plus from the ducting system.

Accessories Termination / Mounting Field Interrogation Multi Purpose Hand Held Interrogator (SHC-1) This versatile commissioning / maintenance tool is certified for hazardous areas and used to reconfigure Searchpoint Optima Plus for different gases and fault diagnostics. The same interrogator can be used with the original Searchpoint Optima and Searchline Excel (open path gas detector) reducing operator training. Certified Junction Boxes A full range of hazardous area certified Ex e and Ex d junction boxes are available. SHC-1 Protection Device This device provides electrical protection for the SHC-1 when used with conventional terminal housings under a gas free permit to work system. HART : Reduce your operational costs and gain enhanced device visibility Searchpoint Optima Plus is available with HART over output. This communication aspect allows Searchpoint Optima Plus to deliver a wide range of added value benefits. What is HART? HART (Highway Addressable Remote Transducer) is a widely used digital communications protocol, which allows users to access live data, status indications and diagnostic information from intelligent field devices. It works by superimposing a digital signal on the existing analogue signal. A key benefit of HART is the fact no additional field cabling is required, because HART uses the device s 4-20 ma signal cable. HART can also help to reduce costs in a number of ways. For example, it eliminates the need for proprietary handheld devices; a field engineer can use a single HART handheld device to access any HART enabled equipment on site. The HART signal can be interrogated from anywhere in the current loop, and this means that users can access diagnostic information without going into the field. This means that if maintenance is required, the scope of work is known before the engineer goes to the device, potentially helping to reduce ongoing maintenance costs. Searchpoint Optima Plus HART interface speaks the language of gas detection Searchpoint Optima Plus HART user interface is designed for gas detection using familiar terminology. engineers have designed the Device Description (DD) file to provide easy to understand messaging on HART host devices, guiding the user through operations and eliminating time wasted referring to manuals to decode generic HART messages. Searchpoint Optima Plus and its DD file are registered with the HART Communication Foundation, having passed the Foundation s rigorous test program. Available functions: View gas reading, configuration and diagnostic information Bump test ma loop calibration Gas calibration Simulate alarm, fault or warning Set device tag, ID and description View active warnings / faults and event history Force ma output to a set level for testing Configure real time clock Configure inhibit, warning and overrange levels Configure alarm threshold Change target gas Password protected access Benefits of using HART Access full information from Searchpoint Optima Plus, anywhere in the current loop No associated infrastructural costs, unlike some other communications protocols; additional communication is achieved without the need for extra cabling Save on set up costs by eliminating the need for proprietary handheld devices Save on long-term costs by enabling proactive not reactive maintenance Save a field engineer investigation trip - know before you go

Technical Summary Searchpoint Optima Plus Specification Measuring Range 0-100% LEL, wide selection of Hydrocarbon gas and vapour calibrations. Different measuring ranges and solvent calibrations available for specialist applications Signal Output autosensing sink or source Inhibit 1-3mA (Default 2mA) Warning 0-6mA (Default 3mA *) Fault 0mA (HART units adjustable to 1mA) Over Range 20-21.5mA (Default 21mA) Digital Output Optional Multidrop Modbus RS485 (via XNX, Optional HART over output (HART version 7) Material 316 stainless steel Weight 1.6kg Accuracy Optima Plus (Hydrocarbon) Baseline < ±1% FSD, 50% FSD <±2% FSD Optima Plus (Ethylene) Baseline < ±2% FSD, 50% FSD <±3% FSD Repeatability < ±2% FSD at 50% FSD Linearity < 5% FSD Response Time T50 < 3 seconds, T90 < 4 seconds (methane) Operational and Certified -40 C to +65 C temperature range Long Term Stability (as defined in EN 60079-29-1) Drift Over Temperature Range (-40 C to 65 C) Baseline Methane 100 %LEL Range: ± 2 %FSD Ethylene 100 %LEL Range: ± 4 %FSD 50 %FSD Methane 100 %LEL Range: ± 4 %FSD Ethylene 100 %LEL Range: ± 5 %FSD Baseline ± 2 %FSD 50 %FSD Methane 100 %LEL Range: ± 0.131 %FSD per C Ethylene 100 %LEL Range: ± 0.078 %FSD per C Variation with Pressure 0.1% (of reading) per mbar Power Supply 18-32Vdc (24Vdc nom), < 4.5W max Environmental Protection IP 66 / 67 Diagnostics Via certified Hand-held Interrogator, XNX or optional HART communications (and Re-calibration) Safety Approvals ATEX: BAS99ATEX2259X II 2 GD Ex d op is IIC Gb Ex tb IIIC Db T96 C (T amb -40 C to +65 C) T86 C (T amb -40 C to +55 C) IP 66/67 UL / CSA: Class 1, Div 1, groups B, C, and D (-40 C to +65 C) IECEx: II 2 GD Ex d op is IIC Gb Ex tb IIIC Db T86 C (T amb -40 C to +55 C) or T96 C (T amb -40 C to +65 C) IP66/67 CU-TR-EX (Russian Customs Union) Performance Approvals EN 60079-29-1 (BVS 03 ATEX G 016 X), CSA C22.2 152., FM ANSI/ISA-12.13.01. Functional Safety IEC61508 Safety Integrity Level 2 EMC Compliance EN 50270:2006 Software EN 50271:2010 Marine Approvals Marine Equipment Directive (MED), type approvals from DNV, BV, ABS, Lloyd s Register * Note for ATEX compliance the warning value should not be set between 3 and 5mA Installation Options 1 2 3 Hazardous Area Safe Area Hazardous Area Safe Area Hazardous Area Safe Area 4 5 Hazardous Area Safe Area Hazardous Area Safe Area Power DCS/PLC Modbus HART SCADA Modbus Modbus SCADA Standard HART handheld device

Gas Detection is able to provide gas detection solutions to meet the requirements of all applications and industries. Contact us in the following ways: Headquarters Europe, Middle East, Africa Life Safety Distribution AG Javastrasse 2 8604 Hegnau Switzerland Tel: +41 (0)44 943 4300 Fax: +41 (0)44 943 4398 gasdetection@honeywell.com Customer Service: Tel: 00800 333 222 44 (Freephone number) Tel: +41 44 943 4380 (Alternative number) Fax: 00800 333 222 55 Middle East Tel: +971 4 450 5800 (Fixed Gas Detection) Middle East Tel: +971 4 450 5852 (Portable Gas Detection) Americas Distribution Inc. 405 Barclay Blvd. Lincolnshire, IL 60069 USA Tel: +1 847 955 8200 Toll free: +1 800 538 0363 Fax: +1 847 955 8210 detectgas@honeywell.com Asia Pacific Asia Pacific #701 Kolon Science Valley (1) 43 Digital-Ro 34-Gil, Guro-Gu Seoul 152-729 Korea Tel: +82 (0) 2 6909 0300 Fax: +82 (0) 2 2025 0388 India Tel: +91 124 4752700 analytics.ap@honeywell.com Technical Support Centres Ltd. 4 Stinsford Road Nuffield Industrial Estate Poole, Dorset, BH17 0RZ United Kingdom Tel: +44 (0) 1202 645 544 Fax: +44 (0) 1202 645 555 ZAC Athélia 4-375 avenue du Mistral Bât B, Espace Mistral 13600 La Ciotat France Tel: +33 (0) 4 42 98 17 75 Fax : +33 (0) 4 42 71 97 05 Elsenheimerstrasse 43 80687 München Germany Tel: +49 89 791 92 20 Fax: +49 89 791 92 43 P.O. Box-45595 6th Street Musaffah Industrial Area Abu Dhabi UAE Tel: +971 2 554 6672 Fax: +971 2 554 6672 EMEA: HAexpert@honeywell.com US: ha.us.service@honeywell.com AP: ha.ap.service@honeywell.com www.honeywellanalytics.com www.raesystems.com Experts in Gas Detection Please Note: While every effort has been made to ensure accuracy in this publication, no responsibility can be accepted for errors or omissions. Data may change, as well as legislation, and you are strongly advised to obtain copies of the most recently issued regulations, standards, and guidelines. This publication is not intended to form the basis of a contract. 11257 _H_Searchpoint Optima Plus_DS0276_V10_EMEAI 12/14 2014