Cleaning a Fibre Optic Solution

Similar documents
Fiber Optic Connector Cleaning and Inspection Kit Instructions

Cleaning of fiber optic connectors

FIBER OPTIC CONNECTOR CLEANERS

Applications Engineering Notes

Titel (auf Masterfolie editierbar) Cleaning of Fiber Connectors

MOST EFFECTIVE METHOD FOR WIPING A FIBRE

2.5mm CLEANCLICKER 750 Fiber Optic Cleaner Performance Verification Report OptiTap-Style Connectors

White Paper: Fiber Contamination, Cleaning and Inspection. Introduction.

SERVICING INFORMATION

FTTc Network Testing Overview

Reflectance, The Hidden Danger That Increases Bit Error Rates in Your Fiber Networks Denver, May 22nd, 2010

HANDLING INSTRUCTIONS for DISPENSA VVS-x

Cleaning Instructions for Symbol IP54 Devices

Fiber Optic Connector Cleaning Solutions

OWL. Laser OWL Series. Operations Guide. Singlemode Light Sources. Optical Wavelength Laboratories. Date: October 1, 2015

Connector Maintenance

3M Crimplok + Connector 8700-UPC & APC SM SC 900 µm

LOVIN MY LAMINATE FLOORING CARE & MAINTENANCE TIPS

SCENE 2x2 INSTALLATION INSTRUCTIONS. Recessed T-Bar GENERAL SAFETY INSTRUCTIONS: NOTE:

Maintenance. Maintenance

White Paper: Standard-Compliant Certification & Best Practices Ensure Fiber End-face Cleanliness to Eliminate the #1 Cause of Fiber Failure

SWITCHBOARD. GENERAL CLEANING m PAGE. NOTICE Not for use or disclosure outside the Bell System except under written agreement

INSTRUCTION MANUAL SC-CX910 VACUUM CLEANER HOUSEHOLD USE ONLY

Prizmatix UV Torch. User Manual

Installation Operation Maintenance

FIBER OPTIC CLEANING AND INSPECTION. Dry Cleaning Wet Cleaning Connector Cleaning Kits Inspection Systems

Contents Setting-up guide

FOREWORD. Only 3 connector parts makes the assembly process both simple and efficient. CONTENTS. 1. Preparation and tools required for assembly

fi-4530c & fi-5530c CONSUMABLE REPLACEMENT

UNSIGNED HARDCOPY NOT CONTROLLED

OF-500 OptiFiber. Advanced Test Equipment Rentals ATEC (2832) Users Manual. Certifying OTDR

Suits SC, ST & FC 2.5mm PC & APC polish 525+ uses. Suits HFOCs in Optitip systems and other FTTx applications

FREE. Health Check. Free Phone A guide to looking after your windows, doors and conservatories

INTERNATIONAL STANDARD

INTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

Using the Remote Control Unit

Ribbon All In One Fusion Splicer

Multi fiber connector: Visual inspection and cleaning guide

Accelerating NBN fiber testing. Tom Ronan Marketing Lead Fiber Optics Melbourne

VACUUM CHAMBER PM TECHNIQUE LAM 9600 Metal ETCH WET-Strip Procedure

Panasonic KV-S5046H/S5076H Scanner Maintenance

L eather Care & Cleaning

S1300/S300 SERIES CONSUMABLE REPLACEMENT

Connections You Can Count On.

White Paper Fiber optic connections: check and clean first, then connect!

Core Alignment All In One Fusion Splicer

Consumable Replacement and Cleaning Instructions


Sources of End Face Contamination on Fiber Optical Interconnects and Recommended Best Practices for Removing the Contaminates

JetSteam Iron Instruction Booklet BIR300

K K 2.360, ,

Utility Master. Steam cleaner. User Guide. Performance is everything. S10 Series. vax.co.uk

Best Practice Briefing

NG4access ODF Platform Standard Chassis Installation Manual

Ensuring Cabling Performance in the Customer-Owned Outside Plant. Keith Foord Product Manager Greenlee Communications

N7100 CONSUMABLE REPLACEMENT

Routine Cleaning of the icolor 700 Continuous Digital Label Press

VACUUM CHAMBER PM TECHNIQUE HITACHI METAL ETCHER

Stereo Turntable System

OptiFiber Pro OTDR Built for the enterprise

IMPORTANT INSTRUCTIONS OPERATING MANUAL

K 2 Basic *EU. K 2 Basic *EU, ,

K K 2.350, ,

K 2 Compact Car. Hooked on tidiness. Sits comfortably in the hand. Integrated accessory storage on the device. Full cleaning power

HOBOT-198 Glass Cleaning Robot User s Manual

K 2 Compact Home. Hooked on tidiness. Sits comfortably in the hand. Full cleaning power

K 2 Car. K 2 Car, ,

Operator's Guide Seiko Epson Corporation. All rights reserved. Printed in XXXXXX

Daily Cleaning Instructions: KL1Plus

Maintenance Guide. Contents

6 Assembling the Blades

K 2 Compact. Hooked on tidiness. Sits comfortably in the hand. Full cleaning power

A few simple steps to ensure perfect water, every time.

Cleaning Yes - Washing No

Owner s Guide and Installation Manual

G 4.10 M. Gasoline Class. Petrol operation. Injector. The powerful petrol engine is easy to start and enables mains-free cleaning.

K 2 Premium Car & Home

A GUIDE TO LOOKING AFTER YOUR WINDOWS AND DOORS

TOSHIBA THE 60 TH SERIES ANALOG COPIERS THE MIDDLE CLASS: AND 4560 MODELS

Fibre Optic Connector and Component Standards Developments & Key Issues in IEC & CENELEC. Philip C Longhurst Corporate Fibre Optic R & D Manager

A guide to looking after your windows, doors and conservatories. spectus n. look, appearance, aspect

fi-4110cu/m3091/m3092 SERIES CONSUMABLE REPLACEMENT

Development of a dry fabric cleaner for miniature parallel optical interface PRIZM LightTurn connector

The True Value of Connector Inspection: New Challenges and Best Practices

LED Flood EX 21. User Manual

K 2 Compact. Hooked on tidiness. Sits comfortably in the hand. Full cleaning power

Keysight 81663A DFB Laser Source Module

K 7. Outstanding performance. Quick Connect. Plug n Clean. Hooked on tidiness

K 2 Full Control. K 2 Full Control, ,

K 5 Premium Full Control

Sticklers Fiber Optic Splice &

ENDOSCOPE REPROCESSOR OER-Pro Operation Manual

SAFETY INFORMATION GO TO VAPAMORE.COM TO SEE THE MR-75 AMICO INSTRUCTIONAL VIDEO

INSTALLATION AND USER MANUAL

RLH Industries, Inc. Cleaning and Testing Fiber Optic Cable. Reference Guide MD A 0507

EdenPURE Bladeless Tower Fan/Heater Instruction Manual

Cree XLamp CM Family LEDs

Regular Corona Surface Treater Maintenance Cuts Scrap, Reduces Downtime, Boosts Productivity By Mark Spaulding with Tom Gilbertson and Matt Rajala

Kambrook - Australia Bourke Road Alexandria NSW 2015 Australia Customer Service Line

fi-4340c CONSUMABLE REPLACEMENT

Transcription:

Before any testing of a Fibre Optic Solution can commence, there are up to 3 steps that need to be completed. Step 1 Inspect the Fibre Connectors for damage, dirt or any other foreign residue that will impact the through put of the signal. This inspection is completed using a Video Scope. Ensure you have the correct adaptor for the connector type (SC, LC, MPO/MTP ). Best practice is to use a Video Scope with the capacity to analyse the connector. o This should also create a report you can add to your records. If the inspection shows a clean connector, DO NOT CLEAN, connect the Fibre as required for testing. o Cleaning a clean connector could introduce dirt. Below is a sample test report using the Fluke Networks FiberInspector Video Scope connected to a DSX-5000 tester. F i b r e C l e a n i n g 2 0 1 8 V e r s i o n 1. 0 P a g e 1 5

Step 2 is only required if Step 1 identifies a failed or dirty connector, for any reason, during inspection. Step 2 Clean the Fibre connector if it is found to be dirty or has any other foreign residue on it. If the connector is chipped or cracked, the connector must be replaced. Below are samples of inspected connectors. Chips are present on the end face of the connector Residue left from cleaning with Alcohol Residue left after touching the connector end face Residue left from wiping on a shirt Clean connector Cleaning the Fibre connector can be undertaken in a number of ways. Following are examples of the 3 main methods for cleaning Fibre connectors that molex recommends. o Method 3 is the preferred method unless a deep clean is required. F i b r e C l e a n i n g 2 0 1 8 V e r s i o n 1. 0 P a g e 2 5

Method 1 The first method is a wet clean. This is a good method the remove dry residue or stubborn dirt. Beware this method may leave a film behind which would require a second clean with an alternative method. This method of cleaning can be completed as follows: Using a lint-free wipe which is dampened with Alcohol Using a pre-packaged Alcohol wipe Method 2 The second method is a dry wipe using a lint-free wipe. This is good to remove residue and light dirt. Method 3 The third method is a dry clean similar to method 2 utilizing a cleaning tool sometimes called a One Click cleaner. This is the preferred cleaning method by molex for the following reasons: Tools are available in a variety of configurations, SC; LC; MPO/MTP Adaptors on the tip retain the connector for cleaning Removal of the adaptor allows cleaning of Fibre ports or connectors in a through adaptor installed in a Fibre tray. o Enabling the cleaning of installed connectors reduces the risk of damage to the Fibre and connector with opening the tray for cleaning. Below are examples of the cleaning tools for SC and LC connectors. o These are suitable for cleaning the Angle Polished Connector (APC) version of SC and LC connectors. Cleaning tools with connectors located in the tip adaptor for cleaning molex part numbers for the cleaners are SC Connector cleaner AFR-00429 LC Connector cleaner AFR-00428 Cleaning tools with adaptor removed and the tip in a through adaptor for cleaning internal connector or a Fibre port requiring cleaning F i b r e C l e a n i n g 2 0 1 8 V e r s i o n 1. 0 P a g e 3 5

Method 3 Continued for the cleaning of MPO/MTP connectors As previously mentioned, any chipped or cracked connectors must be replaced. Below are samples of inspected MPO/MTP connectors. Dirty MPO/MTP connector Clean MPO/MTP connector Due to the width of the MPO/MTP connector, the cleaning process is a more pronounced wipe of the connector. If a wet clean is required, the wiping cloth in the tip could be moistened with Alcohol then insert the connector for a wet clean. o Then you may need to do a standard dry clean to remove any residue. Cleaning tool with connector located in the tip adaptor for cleaning molex part number for the cleaner is MPO/MTP Connector cleaner AFR-00427 Cleaning tool with adaptor removed and the tip in a through adaptor for cleaning internal connector or a Fibre port requiring cleaning F i b r e C l e a n i n g 2 0 1 8 V e r s i o n 1. 0 P a g e 4 5

molex uses MPO/MTP APC connectors as standard which requires additional considerations when cleaning. Note the directional arrow on the cleaner body which indicates the direction of operation for cleaning the connector. o Also note the resulting direction of rotation of the cleaning tip as shown. As the face of the APC connector is angled, it is important to clean in the correct direction as shown below. To ensure correct cleaning, our cleaner and adaptor are keyed for correct alignment as shown below. o This may not be the case with all MPO/MTP cleaners. Step 3 Re-inspect the Fibre connectors that have been cleaned, and repeat cleaning if required, until connector is clean. Now you can conduct the testing of the Fibre Optic Solution. F i b r e C l e a n i n g 2 0 1 8 V e r s i o n 1. 0 P a g e 5 5