Digital 7 Square Plate Magnetic Stirrer

Similar documents
User Manual. MS7-H550-Pro MS7-H550-S MS7-Pro MS7-S

MS-H-Pro-T Magnetic Hotplate-Stirrer with Timer

INSTRUCTION MANUAL. Stirring hotplate (with probe and stand) Brand : (Dragon laboratory)

User Manual. 10-Channel Analog Hotplate Magnetic Stirrer MS-M-S Channel Analog Magnetic Stirrer

PS-3401 Heater / Stirrer

Magnetic Stirring Systems with Heat

BlueSpin Magnetic Hotplate Stirrer

IKA WERKE. IKA Vibrax VXR basic BETRIEBSANLEITUNG D 3 OPERATING INSTRUCTIONS GB 7 MODE D EMPLOI F 11. VXR Reg.-No

Instruction Manual. For All Corning Hot Plates, Stirrers, Stirrer/Hot Plates with Digital Displays, and External Temperature Controller (6795PR)

Distilling & Mixing.

Thermo Scientific Round Top Hotplate Stirrers. Make safety and accuracy part of your routine

Instruction Manual. Model AccuPlate Hotplate AccuPlate Stirrers AccuPlate Hotplate Stirrer 12/10 CLS-EQ-LHP01REV

MS200/300/400 Hotplate Magnetic Stirrer Instruction Manual

Reacti-Therm I and III Heating/Stirring Modules

Intelli-Stirrer MSH-300i Magnetic Stirrer with hot plate

MS200/300/400 Magnetic Stirrer. Instruction Manual

Thermo Scientific Round Top Hotplate Stirrers. Make safety and accuracy part of your routine

Ingenieurbüro M.ZippererGmbH

OPERATIONS MANUAL. Hotplate Stirrer/Hotplate/Magnetic Stirrer Model HTS-1003/HTP-1002/MGS Certified

Pasto Sous vide water bath

Hotplates, Magnetic Stirrers and Stirring Hotplates

HOTPLATES & HOTPLATE STIRRERS

Instruction Manual. Mini Hotplate Mini Stirrer Mini Hotplate Stirrer

Reacti-Therm I and III Heating Modules

Aluminum Heating Mantles

Operation Manual Vortex mixer unitexer 1

OPERATING MANUAL English Chemical Resistant Diaphragm Pump

INSTRUCTION MANUAL. stirring hotplate. VMS-C7 advanced series. Brand :

Digital Heat Block User Manual

Instruction Manual Mini Hotplate Mini Stirrer Mini Hotplate-Stirrer Mini Auto Stirrer Mini Fixed Temperature Hotplate

i-cube Microplate Incubator E10030

StableTemp Digital Hotplates, Stirrers and Stirring Hotplates

Manual v1 Page 1 of 19. Manual. Laboratory autoclave

Infrared Moisture Determination Balance FD-610. Operating Manual

MD-MINI Dry Bath. Instruction Manual

Rotary Tube Furnaces

555 Hotplate 565 Magnetic Stirrer 575 Hotplate-Stirrer

Operation Manual. (Version 1.5.1)

ES-20 Orbital Shaker-Incubator

Rotary evaporator RS 100 PRO

HI COD REACTOR and Test Tube Heater 2008 Series

Int 937. Soldering Station. Instruction Manual. Correct Disposal of this product

Safe. Heating and Mixing. Leading Safety Standards Superior Ease of Use Reduced Cost of Ownership

Professional Series. Instruction Manual Hotplates, Stirrers, Hotplate-Stirrers

Low Speed Centrifuge. Model XC-2415 Model XC-2450 Operating Manual

Note To The User: This product has updated features not yet mentioned in the product manual.

Service: to SLK Laboratory Hot Plates glass made of ideas

FagronLab NP-1 UV. Negative pressure workbench. User Manual

Magnetic Stirrers from CAT. Ingenieurbüro M. Zipperer GmbH. From marketing knowledge to real innovation

Operation Manual R205BV, R209BV

FastGene Plate Centrifuge. Instruction Manual. Catalog No. NG

Magnetic Stirrer BIOSYSTEM DIRECT BIOSYSTEM Operating Manual Issue

50-Pound Portable Ice Maker

Dry Bath Heating Systems

USER MANUAL AND TECHNICAL MANUAL

Instruction Manual for the Revolutionary Science RS-PB-200 Dual Poly Pro Bath

GMH 285 / GMH 285-BNC

Model PT-05 Model PT-06

ASPIRE Laboratory Aspirator

UC152 and US152. Key Features. Hotplate with Stirrer, UC152 US152. Technical Specification. Ordering Information

Advanced Laundry Chemical Dosing System for Single and Multi-Washers

Rules for Safe Operation

ec Preheater User Manual

Vacuum Controller with Control Unit VC 900

Instruction Manual Analog Vortex Mixer with Fixed Cup Head

Model No: Little Devil II (inc ss)

Instruction Manual M6627 / Version 7.4. Slide Drying Bench MH6616 MH6616X1

6-1 Installing Batteries 6-2 Automatic Circuit/Reset Feature 6-3 Feature Sensitivity Adjustment

A2 Automatic Dispenser. User Manual. 100% Recirculation. Hummingbird. A2 Automatic Dispenser V3.0 0

Incubating Shaker with Cooling

Hotplate/stirrers. Hotplate stirrers

Intelligent Lead Free Soldering Station OPERATION and MAINTENANCE MANUAL

Package Contents. Dry Block Heater Power Cord Instruction manual Warranty Card. Serial Number: Date of Purchase: Supplier: Table of Contents

INSTRUCTION MANUAL. Instruction Manual High Throughput Homogenizer

Installation manual Mini Comfort 50 S/L 07/ V EN

NEW products for 2012

OPERATION MANUAL. THE JENCO MODEL 6230 MICROCOMPUTER BASED ph/mv/temp PORTABLE METER JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

DOC JAN06 LT 200

Service Manual for RESmart CPAP V1.0. RESmart TM CPAP System. Service Manual

CAUTION - READ THESE INSTRUCTIONS BEFORE USING THE MACHINE

Operation Manual (Version 1.5.1)

User Manual. TN6900 H&E Slide Stainer. Read Prior to Operation! Always keep this manual near the unit! WP

MICRO-KJELDAHL EQUIPMENT ( MM SERIES ) OPERATING AND SAFETY INSTRUCTIONS

Safe Heating and Mixing

INSTRUCTION MANUAL. Laboratory Equipment Pty Ltd Ph: Fax:

Shop. Item Information. Interface I-100 For V-100/V-7x0. Send item information. Show item in shop. Add item to cart.

One-Touch Dispense. Multi-temp selections. 208 F For tea, coffee, instant noodle. 194 F Keep warm around 194 F. 176 F Keep warm around 176 F.

IMR 5000 Operating Manual S/N: SAMPLE For information only! IMR Environmental Equipment Inc.

StableTemp Hotplates, Stirrers and Stirring Hotplates

INSTRUCTION MANUAL 4-WAY BALL VALVE Digital Manifold

AOYUE INT. Advanced Repairing System NT 701A++ INSTRUCTION MANUAL. Correct Disposal of this product

hotplates stirrers pages

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

Instruction Manual for the Revolutionary Science RS-PB-100 Poly Pro Bath TABLE OF CONTENTS

Tower Ceramic Heater

PR-L2466W- PA. Operating Instructions. High Performance Refrigerator PR-L2466W-PA

Fisher Scientific Isotemp Muffle Furnace 550 Series. Instruction Manual

Operating manual. a Look Solutions 1 product

Open Refrigerated Showcase. Instruction Manual

Colorado SCR. Electric Towel Radiator Operating and Installation Instructions. (Read these instructions carefully and retain for future reference)

Transcription:

Digital 7 Square (Hotplate) Magnetic Stirrer User Manual MS7-Pro Digital 7 Square Plate Magnetic Stirrer MS7-H550-Pro Digital 7 Square Hotplate Magnetic Stirrer Please read the User Manual carefully before use, and follow all operating and safety instructions! www.scilogex.com 12300090

Contents 12.Associated Standards and Regulations 13 Preface 2 13.Technical Data 13 14.Ordering Information 15 Service 2 15.Main Spare Parts 16 Warranty 2 15.1 Spare Parts Diagram 16 1.Safety Instructions 3 15.2 List of Spare Parts 17 2.Proper use 4 3.Inspection 5 3.1 Receiving Inspection 5 3.2 Listing of Items 5 4.Control and Display 5 4.1 Control Elements 5 4.2 Display 6 5.Trial run 7 6.Initialization 8 6.1 Initializing Sequence 8 6.2 Default Settings 8 7.Function: Heating 8 7.1 Working with External Temperature Sensor 9 7.2 Residual Heat Warning(Hot) 9 7.3 Setting the Safety Temperature 10 8.Function: Stirring 10 9.Remote Control 10 10.Faults 11 11.Maintenance and Cleaning 12 1

Preface Welcome to the Digital 7 Square (Hotplate) Magnetic Stirrer User Manual. Users should read this Manual carefully, follow the instructions and procedures, and be aware of all the cautions when using this instrument. Please provide the customer care representative with the following information: Serial number on the rear panel Description of problem (i.e.,hardware or software) Methods and procedures adopted to resolve the problems Your contact information Service When help needed, you can always contact the Service Department of manufacturer/supplier for technical support in the following ways : SCILOGEX, LLC 500 Four Rod Road Suite 122 Berlin, CT 06037 USA Tel:1- (860) 828-5614 Fax:1- (860) 828-5389 E-mail: info@scilogex.com Website:Http://www.scilogex.com Warranty You have purchased a Scilogex instrument. This instrument is warranted to be free from defects in materials and workmanship under normal use and service, for a period of 24 months from the date of invoice. The warranty is extended only to the original purchaser. It shall not apply to any product or parts which have been damaged on account of improper installation, improper connections, misuse, accident or abnormal conditions of operation. For claims under the warranty please contact your local supplier. You may also send the instrument directly to manufacturer, enclosing the invoice copy and by giving reasons for the claim. 2

1.Safety Instructions Warning! Read the operating instructions carefully before use. Ensure that only trained staff works with the instrument. Risk of burn! Caution when touch the housing parts and the hotplate which can reach temperature of 550. Pay attention to the residual heat after switching off. Protective ground contact! Make sure that socket must be grounded (protective ground contact) before use. When working wear personal safety guards to avoid the risk from: - Splashing and evaporation of liquids - Release of toxic or combustible gases Set up the instrument in a spacious area on a stable, clean, non-slip, dry and fireproof surface. Do not operate the instrument in explosive atmospheres, with hazardous substances or under water. 3 Digital 7 Square(Hotplate)Magnetic Stirrer Gradually increase the speed, reduce the speed if : - Stirring bar breaks away due to high speed - The instrument is not running smoothly, or container moves on the base plate Temperature must always be set to at least 50 lower than the fire point of the media used. Be aware of hazards due to: - Flammable materials or media with a low boiling temperature - Overfilling of media - Unsafe container Process pathogenic materials only in closed vessels. Check the instrument and accessories prior to each use. Do not use damaged components. Safe operation is only guaranteed with the accessories described in the Accessories chapter. Accessories must be securely attached to the device and can not come off by themselves. Always disconnect the plug before fitting accessories. Ensure that the external temperature sensor is inserted in the media to a depth of at least 20 mm. When using metal vessels, do not place the temperature sensors on the bottom of the vessel. This can cause excessively high temperatures to be measured especially in media with poor conductivity.

The tip of the measuring sensor must be at least 5 mm from vessel bottom; a distance of 10 mm is ideal. The instrument can only be disconnected from the main power supply by pulling out the main or the connector plug. The voltage stated on the label must correspond to the main power supply. Ensure that the main power supply cable does not touch the hotplate. Do not cover the device. The instrument may only be opened by experts. Keep away from high magnetic field. 2.Proper use The instrument is designed for mixing and/or heating liquids in schools, laboratories or factories. Observe the minimum distances between the devices, between the device and the wall and above the assembly (min. 100 mm). Figure 1 This device is not suitable for using in residential areas or other constraints mentioned in Chapter 1. 4

3.Inspection 3.1 Receiving Inspection Unpack the equipment carefully and check for any damages which may have arisen during transport. Please contact manufacturer/supplier for technical support. Note: If there is any apparent damage to the system, please do not plug it into the power line. 3.2 Listing of Items Items Qty Main unit 1 Power cable 1 User Manual 1 Table 1 4.Control and Display 4.1 Control elements LED Heat (Hotplate model) LCD Temperature Control Knob (Hotplate model) Speed Control Knob Figure 2 Safe Temperature Control Knob LED Stir Figure 3 Power Switch 5

Items Descriptions 4.2 Display Speed control Knob Stir Set the rated rotary speed. The stirring function is switched ON or OFF by pushing the knob. Temperature control knob Heat (Hotplate) Set the rated temperature. The heating function is switched ON or OFF by pushing the knob. LCD LCD displays the real working state and all settings. Figure 4 LED Heat(Hotplate) When the heating function is switched Character Descriptions LED Stir When the stirring function is switched ON, the LED Stir is lit. Temp and Display temperature when the heating function is switched ON. Safe temperature control Knob Power Switch Set safety temperature, stop heating when exceed secure temperature. S w i t c h O N o r O F F t h e instrument. Table 2 Mot Hot Probe Display stirring state when the stirring function is switched ON. Display hot warning if the hotplate temperature is above 50 after switching OFF the heating function. Display when using external probe. 6

Remote Err Rated value/real value Display in case of remote control. Display in case of error happening. Display value in case of heating or stirring function switching ON. Table 3 Note: If both heating and stirring functions have been started at the same time, heating function always has higher priority. If in this case speed is changed via the stirring knob, it displays stirring speed and reverses to temperature in the duration of 5 seconds. 5.Trial run Digital 7 Square(Hotplate)Magnetic Stirrer Make sure the required operating voltage and power supply voltage match. Ensure the socket must be properly grounded. Ensure the power is off. Plug in the power cable,ensure the power is on and begin initializing. Add the medium into the vessel with a stirring bar. Place vessel on the work plate. Set the rated stirring speed and begin. Observe the stirring bar and LCD display. Set the rated temperature and start heating. Observe the real temperature on LCD display. Stop the heating and stirring functions. If these operations above are normal, the device is ready to operate. If these operations are not normal, the device may be damaged during transportation, please contact manufacturer for technical support. 7

6.Initialization 6.1 Initializing sequence Turn on instrument by the power switch. The Heat and Stir LEDs and the LCD display flash about 3 times. LCD displays the work plate, safe temperature limit in SAFE xxx. LCD displays residual heat warning res On/OFF. LCD displays stirring bar breakaway monitoring br On/OFF. LCD displays the Probe characters in case of connecting with external temperature sensors. 6.2 Default settings The following table is supplied with default settings: Items Default settings Setting temperature ( ) 25 Setting rotary speed (rpm) 100 Table 4 7.Function: Heating The device is controlled by digital temperature control technology, which has two separate safe circuits. The hotplate is kept at a constant temperature by a digital control circuit. The hotplate temperature can also be monitored from a separate, adjustable safe circuit. The two temperature sensors (PT1000) internal for temperature control are built into the hotplate. The single external PT1000 can monitor the temperature of sample. If external temperature sensors needed, it must be plugged in before the device is switched ON. Ensure the external temperature sensor connect firmly before heating. Set the temperature via turning the temperature control knob slowly to the ideal value. When the heating function is switched on, the LED Heat will light up and the LCD will display the real temperature. The rated temperature will be displayed on the right-hand side of the LCD as well as Temp and characters. The heating function is switched on or off by pushing heating knob. Instrument is turned on for the setting zone temperature setting when the last shutdown temperature, the common 8

case, set the heating temperature display the actual temperature may have the following differences:. - Hotplate center and outer edge. - The sample container and the container. In order to ensure the accuracy of the temperature inside the container, please use the external temperature sensor PT1000. 7.1 Working with external temperature sensor Manufacture s standard accessory. If the sensor is not plugged in, Probe will flash. If plugged in, Probe will be shown on the digital display to indicate the sensor is operating. The setting value of external temperature sensors and actual temperature are displayed. Safe circuit controls hotplate temperature. Comparing with the temperature control of the hotplate, the external temperature sensor can control the medium s temperature more precisely. Warning! Do not insert or remove sensor while heating. 7.2 Residual heat warning (Hot) Figure 5 The external temperature sensor PT1000 is the In order to prevent the risk of burns from a hotplate, digital hotplate model has a residual heat warning function. When the heating function is switched off and the hotplate temperature is still above 50, Hot will flash to warn that there is a hazard of burns from the hotplate (Figure 6).When the hotplate temperature drops to below 50, the unit will automatically switch off. If users want to turn off the LCD immediately, just pull out the plug directly. When the plug is pulled out, the residual heat warning function can not be run. 9

8.Function: Stirring Figure 6 7.3 Setting the safety temperature The safety temperature can be set as follows: Adjust the temperature setting key to set the safety temperature. The function stirring is switched on or off via rotating stirring knob. The speed is set on the knob (100 to 1500 rpm in steps of 10 rpm ). When both of function heating and stirring are switched on and those above operations are done, the LCD will shift to the speed value and come back to the temperature value in about 5 seconds. 9. Remote control Figure 7 10

The unit can be controlled from an external PC (using the dedicated software) via the RS232 C serial interface fitted to the unit. Data communication from laboratory instrument to computer is only possible on demand of the computer. The functions of the interface lines between laboratory instrument and automation system are selected from the specified signals of the EIA-standard RS232C, corresponding with DIN66020 Part 1. The allotment of the bushing can be taken from Figure 7. Transmission method: Asynchronous signal transmission in start-stop-operation. Mode of transmission:fully Duplex.1start bit; 7 character bits; 1stop bit. Transmission speed: 9600 bit/s. Start remote control knob LED display Remote. 10.Faults Note: F o r b i d t o i n s e r t o r r e m o v e t h e R S 2 3 2 C communication line when switch on! Instruments can not be power ON - Check whether the power cable is plugged in - Check whether the fuse is broken or loose Fault in power on self test - Switch OFF the unit, then switch ON and reset the instruments to factory default setting. Temperature can switched on not reach set point - Check whether the safety temperature value is set too low. Stir speed can not reach set point - Check whether the stirring bar breakaway monitoring is ON. - Excessive medium viscosity may cause abnormal speed reduction of the motor. Heating or stirring function do not start when knob is pressed. - Check whether the unit is in the mode setting program, - Exit from the mode setting and restart the heating/ stirring functions. Unit do not power down when switched off. - Check if the residual heat warning function is still ON and hotplate temperature is above 50 (the LCD still works and Hot flashes). If these faults are not resolved,please set the instruments to factory default setting or take the unit to technical service center. 11

11.Maintenance and Cleaning Proper maintenance can keep instruments working properly and lengthen its lifetime. Do not spray cleanser into the instrument when cleaning. Unplug the power line when cleaning. Only use recommended cleansers: Dyes Construction materials Cosmetics Isopropyl alcohol Water containing tenside / Isopropyl alcohol Water containing tenside / Isopropyl alcohol packaging carton. Storage packing is not sufficient for the back dispatch. Use additionally a suitable transportation packing. The enamel makes the hotplate easier to care for and more resistant to acids and bases. Because of it, however, the hotplate is also more susceptible to extreme fluctuations in temperature and the force of impact. This can result in cracks forming or the coating flaking off. Warning! Cut off power when maintenance and cleaning. Foodstuffs Fuels Water containing tenside Water containing tenside Wear the proper protective gloves during cleaning of the instrument. B e f o r e u s i n g o t h e r m e t h o d f o r c l e a n i n g o r decontamination, the user must ascertain with the manufacturer that this method will not harm the instrument. Send in the case of service the instrument back in the 12

1 2. A s s o c i a t e d s t a n d a r d s a n d regulations Construction in accordance with the following safety standards: EN 61010-1 UL 3101-1 CAN/CSA C22.2(1010-1) EN 61010-2-10 Construction in accordance with the following EMC standards: EN 61326-1 Associated EU guidelines: EMC-guidelines: 89/336/EWG Instrument guidelines: 73/023/EWG * The above standards will be available from July 2011. 13.Technical data Digital 7 Square(Hotplate)Magnetic Stirrer Voltage [VAC] 100-120/200-240 Frequency [Hz] 50/60 Power [W] Stirring point position quantity 1 Max. stirring quantity (H2O) [L] 20 Max. magnetic bar [mm] 80 10 Motor type Max. power input of motor [W] 18 Max. power output of motor [W] 10 1050(hotplate model) 50 Brushless motor Speed range[rpm] 100-1500 Rotary speed display LCD Speed display accuracy [rpm] 1 Hotplate material Glass ceramic Dimensions of workplate (mm) 184 184 13

Dimensions of heating (mm) 176 176 Weight [kg] 5.3 Heating power[w] Temperature range [ ] Temperature display[ ] Temperature display accuracy [ ] Control accuracy of heating temperature [ ] The safety temperature range of the hotplate [ ] Temperature sensor in medium Control accuracy of heating temperature with temperature sensor [ ] Residual heat warning 1000(hotplate model) RT-550 (hotplate model) LCD(hotplate model) 0.1(hotplate model) 1(100 below)/ ±1%(100 above) (hotplate model) 100-580 (hotplate model) PT1000 (hotplate model) 0.2(hotplate model) 50 (hotplate model) Permitted ambient temperature[ ] 5-40 Permitted relative humidity 80% Protection class acc. to DIN 60529 IP21 RS232 interface Yes Table 5 Dimensions (mm) 215 360 112 14

14.Ordering information Cat No. 813223009999 813223019999 813223029999 Descriptions MS7-H550-Pro Digital 7 Square Hotplate Magnetic Stirrer, glass ceramics hotplate, USA plug, 110V/50Hz/60Hz MS7-H550-Pro Digital 7 Square Hotplate Magnetic Stirrer, glass ceramics hotplate, Cn plug, 220V/50Hz/60Hz MS7-H550-Pro Digital 7 Square Hotplate Magnetic Stirrer, glass ceramics hotplate, Euro plug, 220V/50Hz/60Hz 813213029999 813213039999 Accessories 18900016 18900084 Digital 7 Square(Hotplate)Magnetic Stirrer MS7-Pro Digital 7 Square Plate Magnetic Stirrer, glass ceramics plate, Euro plug, 220V/50Hz/60Hz MS7-Pro Digital 7 Square Plate Magnetic Stirrer, glass ceramics plate, UK plug, 220V/50Hz/60Hz PT1000 Temperature sensor for digital hotplate model, length 230mm PT1000 Temperature sensor for digital hotplate model, length 100mm 813223039999 813213009999 813213019999 MS7-H550-Pro Digital 7 Square H o t p l a t e M a g n e t i c S t i r r e r, g l a s s ceramics hotplate, UK plug, UK plug, 220V/50Hz/60Hz MS7-Pro Digital 7 Square Plate Magnetic Stirrer, glass ceramics plate, USA plug, 110V/50Hz/60Hz MS7-Pro Digital 7 Square Plate Magnetic Stirrer, glass ceramics plate, Cn plug, 220V/50Hz/60Hz 18900017 Support clamp of PT1000 18900002 18900003 18900004 MS135.2 Red quarter pie, 11 holes, 4 ml reaction vessel, Ø15.2mm, 20mm depth MS135.3 Purple quarter pie, 4 holes, 20 ml reaction vessel, Ø28mm, 24mm depth MS135.4 Blue quarter pie, 4 holes,30 ml reaction vessel, Ø28mm, 30mm depth 15

18900005 18900048 18900049 18100319 MS135.5 Black quarter pie, 4 holes,40 ml reaction vessel, Ø28mm, 43mm depth MS135.6 Green quarter pie, 6 holes, 8ml reaction vessel, Ø17.75mm, 26mm depth M S 1 3 5. 7 G o l d e n q u a r t e r p i e, 4 holesø16ml reaction vessel, Ø21.6mm, 31.7mm depth 9-Pin interface line, suitable for StirPC-V2 software. 15.Main spare parts 15.1 Spare parts diagram Table 6 Note:The software StirPC-V2 can be freely downloaded from our website www.scilogex.com. Figure 8 16

15.2 List of spare parts Item Spare parts Item Spare parts 1 Work plate 9 Main circuit board 2 Hole for external temperature 10 Driver circuit board sensor 3 Mains switch 11 Heating parts 4 Housing 12 5 Control panel 13 6 External temperature sensors socket Direct-current brushless motor Internal temperature sensor 14 Permanent magnet 7 Remote control socket 15 Protective plate 8 Main socket 16 Rubber foot 17

SCILOGEX, LLC 500 Four Rod Road Suite 122 Berlin, CT 06037 USA Tel:1- (860) 828-5614 Fax:1- (860) 828-5389 E-mail: info@scilogex.com Website:Http://www.scilogex.com