WAIWELA SERIES-TWO WATER HEATERS

Similar documents
EEMAX SERIES-TWO WATER HEATERS

EEMAX THREE MODULE, SINGLE PHASE WATER HEATERS

EEMAX ProAdvantage Series 1

POWERSTAR PS19T / PS28T, SINGLE PHASE WATER HEATERS

EEMAX HOME ADVANTAGE

ELECTRIC INSTANTANEOUS WATER HEATER INSTALLATION GUIDE AND OWNERS MANUAL THERMOSTATIC

EEMAX PROADVANTAGE ELECTRIC INSTANTANEOUS WATER HEATER INSTALLATION GUIDE AND OWNERS MANUAL

SERIES THREE 480 VOLT 3 PHASE DELTA ELECTRIC INSTANTANEOUS WATER HEATER

INSTALLATION GUIDE AND OWNER S MANUAL

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL FOR

INSTALLATION GUIDE AND OWNER S MANUAL. AccuMix II ELECTRIC INSTANTANEOUS WATER HEATER WITH ASSE 1070 APPROVED MIXING VALVE

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL

TABLE 1 Electrical Specifications

TABLE 1 Electrical Specifications. Phase

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

HOMEADVANTAGE II IMPORTANT SAFETY INFORMATION

SEISCO SUPERCHARGER EXTENDER/BOOSTER INSTALLATION GUIDE & OWNERS MANUAL

INSTANT-FLOW C-MICRO WATER HEATER

PRO SERIES IMPORTANT SAFETY INFORMATION

OPERATION AND INSTALLATION UTILISATION ET INSTALLATION

INSTANT-FLOW C-MICRO WATER HEATER

OPERATING AND INSTALLATION MANUAL

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION

OPERATING AND INSTALLATION MANUAL

EcoSmart Troubleshooting Guide

SAVE THESE INSTRUCTIONS

TRONIC 6000C. Tankless electric whole house water heaters. Models: WH17 / WH27. [en] Installation Manual and Operating Instructions

ЭКСПЛУАТАЦИЯ И МОНТАЖ ПРОТОЧНЫЕ ВОДОНАГРЕВАТЕЛИ С ЭЛЕКТРОННЫМ УПРАВЛЕНИЕМ

Controlled Energy Corp. 340 Mad River Park Waitsfield, VT TOLL FREE

Flow Factor ~

ECCOTEMP. Point of Use Tankless Water Heaters EP-2.4 / EP-7.0. Installation and Operating Instruction Manual. Shop Online.

DHC-E TANKLESS ELECTRIC WATER HEATERS INSTALLATION INSTRUCTIONS FOR THE LICENSED PLUMBER AND ELECTRICIAN

Instruction Sheet AquaMotionHot One AMH1K-1 Point of Use Hot Water Recirculation System

HEATRAE SADIA. Installation and User Instructions for the UTC Undersink Vented Water Heater

STEAMPRO. Steam Generator Troubleshooting and Service Guide

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL AUTOBOOSTER IMPORTANT SAFETY INFORMATION

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

SERVICE MANUAL. Bradford White ElectriFLEX HD (Heavy Duty) Commercial Electric Water Heater CEHD SERIES Immersion Thermostat Models

Intatherm Safe Touch Basin Tap IT1008CP

Flow Controlled EFC - MODELS

GEOTHERMAL STORAGE TANKS

INSTALLATION AND SERVICE MANUAL

12 kw Electric Tankless Water Heater Troubleshooting Guide

REDRING POWERSTREAM UNVENTED INSTANTANEOUS WATER HEATER. Installation and User Guide

Low kw Electric Tankless Water Heater Troubleshooting Guide

Installation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324

SAVE THESE INSTRUCTIONS

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR THE HUBBELL MODEL TX / HX TANKLESS WATER HEATER

Partner. Peerless. Indirect-Fired. Water Heater. Installation, Operation & Maintenance Manual

Installation Instructions

American Dish Service

H 2. Hot Water Storage/ Booster Tanks. For Single Tank Installations INSTALLATION, OPERATION & MAINTENANCE MANUAL

SMARTBOOST IMPORTANT SAFETY INFORMATION

Unvented Electric Water Heater 10/15 litre Undersink

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL TANKBUDDY IMPORTANT SAFETY INFORMATION

Installation Instructions

INSTALLATION INSTRUCTIONS FOR MULTI-UNIT RESIDENTIAL APPLICATIONS INSTALLATION INSTRUCTIONS ARE PER UNIT MODELS: RS-502C, RS-503C, RS-702C, RS-703C

INSTALLATION OPERATION MAINTENANCE

Low Water Cutoff (LWCO) IQ Option Card p/n , for Hot Water Boilers

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

OPERATION AND INSTALLATION

QUICK START GUIDE 04 WARNING 05 PACK CONTENTS 05 TECHNICAL SPECIFICATIONS 05 ELECTRICAL REQUIREMENTS 05 WIRING DIAGRAM 07 INSTALLATION OPTIONS

AQUA PREMIER ELECTRONIC ELECTRIC SHOWER. Installation and User Guide

INSTALLATION & SERVICE MANUAL

Installation & Operating Guide

Your safety and the safety of others are very important.

Thermostatic bar mixer valve with adjustable head Installation guide

REDRING POWERSTREAM UNVENTED INSTANTANEOUS WATER HEATER. Installation and User Guide

INSTALLATION INSTRUCTIONS

Select. Sutter PlaceTM. Instruction Manual. A Kichler Select ceiling fan

60" Tulle PatioTM. Instruction Manual. A Kichler Select ceiling fan

Congratulations! You've just purchased a new Santon tankless water heater and will soon begin to enjoy the benefits of going tankless.

Electrical Installation Instructions

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

Francis Pegler Memento Single Sequential Exposed Thermostatic Shower

ALUMA INSTRUCTION MANUAL WARRANTY CERTIFICATE

Electric Mini Tank Water Heaters ME10 ME25 ME40 ME60

Instant Hot Water Dispenser Owner s Manual

SPACESAVER INSTRUCTION MANUAL WARRANTY CERTIFICATE

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

OPERATION & INSTALLATION MANUAL

Dishwasher Installation Manual

1. SAFETY RULES WARNING WARNING. 8. Avoid placing objects in the path of the blades.

KD-27A SERIES DISHWASHERS

Installation Instructions

AquaSaver DISPOSER CONTROL CENTER Installation Manual. Model AS-101K

IMPORTANT INFORMATION. Revised Dishwasher Installation Instructions

ELECTRIC SPA-PAK HEATER INSTALLATION & OPERATING INSTRUCTIONS

OPERATION AND INSTALLATION

CAUTION WARNING INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE WHOLE HOME DEHUMIDIFIER MODEL HCWH-065 (Y3013) DEHUMIDIFIERS

Eemax, Inc. Electric Tankless Water Heaters

Installation Instructions

CURTIS GOLD CUP BREWER

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

42 Kevlar. Instruction Manual. Kichler Lighting 7711 East Pleasant Valley Road P.O. Box Cleveland, Ohio

Clean Water Made Easy. CWS Time Clock Softener Installation & Start Up Guide. Questions?

ELSTON 52 CEILING FAN

SEISCO MOUNTING CLEARANCES

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL FOR THE HUBBELL TANKLESS WATER HEATER

Transcription:

WAIWELA SERIES-TWO WATER HEATERS ELECTRIC INSTANTANEOUS WATER HEATER INSTALLATION GUIDE AND OWNERS MANUAL MODELS COVERED WET-12 T, TC, T2-240/208 V SPECIAL, V READ THE GENERAL SAFETY SECTION BEGINNING ON THE INSIDE COVER AND THEN THIS ENTIRE MANUAL BEFORE INSTALLING OR OPERATING THIS WATER HEATER. IF YOU DON T FOLLOW THE SAFETY RULES, THE UNIT WILL NOT OPERATE PROPERLY AND IT COULD CAUSE DEATH, SERIOUS BODILY INJURY AND/OR PROPERTY DAMAGE. READ ALSO THE ENCLOSED WARRANTY CARD. WARRANTY OF THIS WATER HEATER WILL DEPEND ON PROPER INSTALLATION AND OPERATION. THE WARRANTY SHALL BE VOID IF THE DESIGN HAS BEEN ALTERED IN ANY WAY WHATSOEVER. THE MANUFACTURER OF THIS HEATER WILL NOT BE LIABLE FOR ANY DAMAGES BECAUSE OF FAILURE TO COMPLY WITH THE INSTALLATION AND OPERATING INSTRUCTIONS OUTLINED ON THE FOLLOWING PAGES. THE INSTALLATION MUST CONFORM WITH THE INSTRUCTIONS IN THIS MANUAL; ELECTRIC COMPANY RULES; AND THE LOCAL CODES, OR IN THE ABSENCE OF LOCAL CODES, WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE. THIS PUBLICATION IS AVAILABLE FROM YOUR LOCAL GOVERNMENT OR PUBLIC LIBRARY OR ELECTRIC COMPANY OR BY WRITING UNDERWRITERS LABORATORIES, 333 PFINGSTEN ROAD NORTHBROOK, IL, 60062. IF YOU REQUIRE ANY HELP OR HAVE ANY QUESTIONS RELATING TO THE INSTALLATION OR PERFORMANCE OF THIS HEATER, PLEASE CALL OUR TECHNICAL SERVICE DEPARTMENT TOLLFREE : 1-800-543-6163. HAVE THE INFORMATION LISTED BELOW BEFORE CALLING : SERIAL NO. MODEL NO. WET-12 INSTALLATION DATE 1 9/23/2008

GENERAL SAFETY The WaiWela Series Two heater is specifically designed to take in cold water and heat it to temperatures suitable for normal domestic usage up to a maximum of 125 F (52 C). To obtain optimum performance and energy savings, the unit should be located as near as possible to the point of use. The unit is supplied with 3/4 NPT pipe connections. Under no circumstances use a blow torch on pipe which is connected to the heater (serious damage to the electronic flow switch will result). Carefully use Teflon tape, ensuring no debris enter the heater. Do not use pipe dope. Also, ensure that the pipes are clear of installation debris before fitting the heater. THIS HEATER MUST HAVE ONE DEDICATED INDEPENDENT CIRCUIT, USING CORRECTLY RATED WIRES AND CIRCUIT BREAKER. FAILURE TO GROUND THE SYSTEM MAY RESULT IN DEATH OR SERIOUS INJURY. IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE DEATH, SERIOUS BODILY INJURY OR PROPERTY DAMAGE. REFER TO THIS MANUAL FOR ASSISTANCE OR CONSULT THE LOCAL ELECTRIC UTILITY FOR FURTHER INFORMATION. WATER HEATERS EQUIPPED FOR ONE VOLTAGE ONLY: THIS WATER HEATER IS EQUIPPED FOR ONE VOLTAGE TYPE ONLY: CHECK THE RATING PLATE ON THE FRONT COVER OF UNIT FOR THE CORRECT VOLTAGE. DO NOT USE THIS WATER HEATER WITH ANY OTHER VOLTAGE OTHER THAN THE ONE SHOWN ON THE MODEL RATING PLATE. FAILURE TO USE THE CORRECT VOLTAGE CAN CAUSE PROBLEMS WHICH CAN RESULT IN DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE. IF YOU HAVE ANY QUESTIONS OR DOUBTS CONSULT WAIWELA OR YOUR ELECTRIC COMPANY. HAZARD OF ELECTRICAL SHOCK! BEFORE REMOVING THE COVER OR SERVICING THE WATER HEATER, MAKE SURE THE ELECTRICAL SUPPLY TO THE WATER HEATER IS TURNED OFF. FAILURE TO DO THIS COULD RESULT IN DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE. 2

MINIMUM - 8 CLEARANCE ABOVE UNIT serial # MOUNTING HOLES Factory installed jumpers from L1 L1 and L2 L2 L1 L2 L1 L2 LUG TERMINALS AT RELAYS ELECTRICAL HOOK-UP 240V/208V GROUND LUG To independent circuit breaker Figure 1 3

I. MOUNTING THE UNIT 1) The unit should be mounted as close to the point of use as possible. For example, directly beneath the sink is ideal. Do not install the heater above a faucet or point of use because the siphoning effect may drain the heater which can cause premature element burn out. 2) This unit must only be mounted in a vertical position with the water fittings located at the bottom of the unit. Mounting other than in the vertical position WILL cause element burn out and cause permanent damage to the water heater. 3) The cold water inlet is on the right hand side and the hot water outlet is on the left hand side. Under NO circumstances can these be reversed. 4) Leave a minimum of 8 above the unit for easy replacement of the element. 5) The heater should be fixed to the wall using screws in the four mounting holes at each corner of the backplate. NOTE: The heater should be installed below the level of all hot water outlets serviced by this heater. NOTE: PRESSURE AND TEMPERATURE RELIEF VALVE These units are not required by UL to have a Pressure and Temperature Relief Valve (PTRV). You should check with local codes to find out if one is required in your area. If local codes require the use of a temperature and pressure relief valve it should be installed on the outlet hot water pipe before the outlet ball valve. Figure 2 Hot Cold Installation directly beneath the sink is ideal WaiWela TO SHOWER 4 HOT OUTLET COLD INLET

II. PLUMBING HOOK-UP 1) The unit is supplied with ¾ NPT fittings (Figure 3), USE THESE. DO NOT USE PIPE DOPE AND DO NOT SOLDER TO THE INLET OR OUTLET. 2) Take care to ensure that the pipes are correctly aligned with the inlet and outlet bosses in order to avoid excessive stress on the heater body molding. NOTE: When soldering pipe joints remove heater from the wall. Serious damage can occur if any soldering is done while pipes are connected to the heater. Run water through the supply pipe to remove all debris from the pipe before connecting the heater. Failure to do so could cause damage to the flow switch. 3) Install isolating valves (full flow ball valve type) on both inlet and outlet pipes. This allows unit to be isolated for maintenance purposes. (Fig. 1) 4) When all plumbing is complete, fully check the system for water leaks at all the plumbing connections. If a leak is present take corrective action. If the leak is at a compression fitting, slowly tighten the compression nut until it stops. Fully open both inlet and outlet BALL VALVES. Run all the hot water outlets fed by this heater one at a time, for a minute or two, until the water flow is continuous, free from gulping and from all visible air pockets. Figure 3 HOT OUTLET ¾ NPT FITTING DO NOT SOLDER COLD INLET ¾ NPT FITTING DO NOT SOLDER 4 NOTE: ALL MOUNTING AND PLUMBING MUST BE COMPLETE BEFORE YOU PROCEED WITH ELECTRICAL HOOK-UP. TEST THE INSTALLATION FOR LEAKS BEFORE CONNECTING THE ELECTRICAL SUPPLY. 5

III. ELECTRICAL HOOK-UP BEFORE BEGINNING ANY WORK ON THE ELECTRICAL INSTALLATION, BE SURE THE SWITCH AT MAIN BREAKER PANEL IS OFF TO AVOID ANY DANGER OF ELECTRICAL SHOCK. Series-two heaters are manufactured to the following specifications: Figure 4 MODEL TYPE OUTPUT / kw VOLTAGE / V AMPERAGE EX 120 11.5 *240 47.9 Amps SPECIAL * Units rated for 240 V can operate at 220 V or 208V with reduced output. The output will vary in accordance with the following ratios: volts output ratio 208 volts 220 volts 240 volts.75.84 1.0 This unit must have its own independent circuit, using 1 SET of UL listed 2 conductor and ground core copper wire cable of the appropriate size protected by 1 independent correctly rated Double Pole breaker. (208, 220, 240 V, see Figures 4 and 5). Wire entry into the unit must be made through the hole provided in the flange on the backplate. The live wires should be connected to the slots in the terminal block marked L1 and L2. The ground lead must be connected to the slot marked GND. GROUND MUST BE BROUGHT TO THE GROUND AT THE CIRCUIT BREAKER PANEL. Figure 5 Circuit Breaker Panel 1 independent correctly rated Double pole breaker (240/208 Volts) OFF OFF ON ON DANGER FAILURE TO GROUND THE SYSTEM MAY RESULT IN DEATH OR SERIOUS INJURY. 6

IV. COMMISSIONING YOUR HEATER IMPORTANT BEFORE SWITCHING ON THE POWER AT THE MAIN CIRCUIT BREAKER PANEL MAKE SURE THAT THE HOT WATER CIRCUIT IS FREE OF AIR POCKETS OR ELSE PREMATURE FAILURE OF THE ELEMENT WILL OCCUR. TO DO THIS OPEN ALL HOT WATER OUTLETS ONE AT A TIME FOR A MINUTE OR TWO UNTIL THE WATER FLOW IS CONTINUOUS AND FREE FROM GULPING AND FREE FROM VISIBLE AIR POCKETS. 1) Open fully both inlet and outlet valves at the heater. 2) Open any hot water outlet in the system. If the outlet is a single lever mixer type turn to the hottest position. Run for one minute to clear all the air from the system. 3) Slowly close OUTLET ball valve until the water flow from the faucet just starts to reduce. NOTE: This process has two effects. One, any air in the system will be purged out. Two, the heater units will be pressurized at the supply pressure. This will prevent the elements burning when energized.(note: Keep water flowing whilst carrying out the procedures outlined below.) GO TO APPROPRIATE SECTION FOR YOUR MODEL NOTE: For the following sections the first unit is the right hand heating module and the second unit is the left hand heating module. T MODELS a) Switch on the power to the first unit. The power indicator light should illuminate. b) Switch on the power to the second unit, again the power indicator light should illuminate. Note: This light should pulse On and Off at first and after about 20-30 seconds it should stay fully on. c) Use the OUTLET ball valve to gradually reduce the water flow until the power indicator light on the second unit begins to pulsate. The water temperature should now be approximately 125 F. d) The thermostat is now set and the water temperature will always be the same when the indicator light is pulsing. e) Increasing water flow (above the flow rate at which the thermostatic control is no longer effective) will reduce the water temperature. P2 MODELS a) Switch on the power to the first unit. The power indicator light should illuminate. b) Switch on the power to the second unit, again the power indicator light should illuminate. c) Temperature is controlled on this unit by controlling the amount of water flowing through it. e.g. The higher the water flow rate the lower the water temperature and vice-versa. 7

TC and T2 MODELS a) Switch on the power to the unit, the power indicator light should illuminate. Note: This light should pulse On and Off at first and after about 20-30 seconds it should stay fully on. b) Use the OUTLET ball valve to gradually reduce the water flow until the power indicator lights on both units begin to pulsate. The water temperature should now be approximately 125 F. For T, TC, and T2 Models If a lower temperature is required, turn the temperature adjustment screw(s) counter-clockwise about 1/8 of a turn (See Figure 1). Wait 15-20 seconds and check the temperature at the fixture. Repeat this process until the desired temperature has been achieved. (For T2 models try to adjust both temperature adjustment screws by about the same amount so that the lights pulse at the same rate.) If you have reduced the temperature considerably from the 125 F setting, you could now open up the outlet ball valve slightly to achieve a higher rate of flow. When the indicator light is on continuously, the unit is emitting full power. When it is pulsing, the unit is modulating the power to achieve the temperature set by means of the temperature adjustment screw. ALL HEATERS In order to obtain good control at single lever mixer type faucets (single spout) the cold water supply to the faucet should be restricted to give approximately the same flow rate of cold water to the faucet as the hot water coming from your WaiWela heater. The simplest method of doing this is by partially closing the cold water valve under the sink. MAXIMUM TEMPERATURE RISE CHART ( 0 F ) OUTPUT 0.75 1 1.25 1.5 2 2.5 3 11.5 kw 104 78 62 52 39 31 26 8

TROUBLESHOOTING SYMPTOM A : NO HEAT - INDICATOR LIGHT OFF 1) ELECTRIC SUPPLY IS OFF Turn on the main circuit breaker. 2) NO OR LOW WATER FLOW Ensure that the minimum flow rate to switch on your heater is met. T, TC Models 0.75gpm T2 Models 1.5gpm P2 Models 1.5gpm Also check that the inlet filter screen is clear from any debris. This is located in the brass inlet boss. 3) WATER CONNECTIONS ARE REVERSED Cold water inlet = right side, hot water outlet = left side. 4) ELEMENT BURNED OUT TURN OFF THE MAIN CIRCUIT BREAKER! Using an ohmmeter test the resistance of the heating element across the two threaded termination rods on top of the element. The resistance reading should be under 10 ohms. If the resistance is much greater than this value, call Waiwela for a replacement element. 5) ECO TRIPPED (High Limit Thermostat) TURN OFF THE MAIN CIRCUIT BREAKER! Reset by pushing in red button on each heater module. SYMPTOM B : NO HEAT OR LOW TEMPERATURE WITH INDICATOR LIGHT ON 1) WATER FLOW TOO HIGH Reduce the water flow by using an outlet ball valve. See page 8 for temperature rise at various flow rates. 2) INCORRECT POWER SUPPLY Make sure that the unit is connected to the voltage supply specified on the rating label on the front cover of the unit and no other. 3) ELEMENT BURNED OUT TURN OFF THE MAIN CIRCUIT BREAKER! Repeat the steps from paragraph 4 above. 4)THERMOSTAT ADJUSTMENT SCREW NOT TURNED UP (Models T, TC and T2 only.) Turn both thermostat adjustment screws clockwise in small increments until the indicator light(s) remains on. Take care not to force the screw past it s stop position. 5) ECO TRIPPED (High Limit Thermostat) See Paragraph 5 above. 9

WAIWELA REPLACEMENT PARTS DIAGRAM serial # REPLACEMENT HEATER CORE ASSEMBLY EX1000 5.75KW @240V Triac - EX 18 ECO (High Limit Thermostat) Push to Reset To 2 nd module Temperature Adjustment Knob CONTROL BOARDS L1 L2 L1 L2 7 - Wire EX 100G 8 - Wire EX 284 Inlet isolating valveball valve. (Always leave fully open when unit is in service.) To appropriate circuit breaker WaiWela, 5350 Joliet St. #2 Denver, CO 80239 Tel: 1-800-543-6163 10

CIRCUIT BOARD DIAGRAM RELAY (ORG) TO ECO T/C (BLU) T/C (BLU) POWER (BLK) L1 FROM RELAY LINE SIDE TRIAC GATE (BLK) EL/L1 (BLK) ELEMENT RING EL/L2-N (RED or WHT) ELEMENT RING T/C (BLU) 2 PIN CONNECTOR RELAY (ORG) TO ECO RELAY (ORG) TO RELAY COIL L1 POWER (BLK) FROM RELAY LINE SIDE TRIAC (BLK) EL/L (BLK) ELEMENT RING L2-N POWER (RED/WHT) FROM RELAY LINE SIDE 7 - Wire EX 100G 6 Wire + T/C EX 284 11