AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL

Similar documents
Thermoelectric Assemblies

Thermoelectric Assemblies

KNHE48 SERIES WATER-TO-AIR HEAT EXCHANGER

ADVANTAGE SERIES KXRP28 AIR-TO-AIR HEAT EXCHANGER

KPHE24 SERIES WATER-TO-AIR HEAT EXCHANGER

KPHE32 SERIES WATER-TO-AIR HEAT EXCHANGER

KNHE30 SERIES WATER-TO-AIR HEAT EXCHANGER

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. H 2015 Pentair Equipment Protection P/N

ADVANTAGE SERIES KXRP33 AIR-TO-AIR HEAT EXCHANGER

KNHX32 SERIES NEMA 4/4X AIR-TO-AIR HEAT EXCHANGERS

WL User Manual. Innovative Technology for a Connected World. global solutions: local support TM

ADVANTAGE SERIES KXRP47 AIR-TO-AIR HEAT EXCHANGER

Panel Mounted Heat Exchangers by Dantherm, Inc.

Rev. E 2013 Pentair Technical Products P/N Distributed by: McLean Parts

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL

Product Information Packet

ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL

Blade Series Heat Exchanger Operation and Installation

THE BARCLAY HUGGER CEILING FAN INSTALLATION INSTRUCTIONS

T-SERIES Air Conditioner. T62 Model INSTRUCTION MANUAL nvent Rev. F P/N

IC6-B, IC6-MB, IC6-BB, IC8-B, IC8-MB, IC8-BB, ICA6-B, ICA6-MB, ICA6-BB, IC6DVC-B, BS650 ICS6-MB, ICS8-MB

INSTALLATION USE & CARE MANUAL ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER

Product Information Packet

BX Series. Installation, Operation, Maintenance Instructions & Spare Parts

FOR EASY, FAST INSTALLATION AND FOR RESULTS

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL. Rev. F 2015 Pentair Equipment Protection P/N

Condensate Pump. Installation and Safety Instructions CP-16 CP

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

RPI Industries, Inc.

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL. Rev. D 2015 Pentair Equipment Protection P/N

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Ice Cream Freezers

Environmental Monitoring SmartSlot Card

SPECTRACOOL Air Conditioner. N17 Model INSTRUCTION MANUAL. Rev. G 2015 Pentair Equipment Protection P/N

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

DUST FREE CARBON Whole House Air Purifier

RPI Industries, Inc.

PROAIR Air Conditioner

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

Operation Manual SA Vent. Models Kona, Pali and Mistral

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

RPI Industries, Inc.

Warnings 2. Installation Instructions 3. Wiring Instructions 3. Mounting Instructions 4-5. Replacement Element Installation 5. Replacement Parts 5-6

Warnings 2. Installation Instructions 3. Wiring Instructions 3. Mounting Instructions 4. Replacement Element Installation 5. Replacement Parts 5

THE NIKKO CEILING FAN INSTALLATION INSTRUCTIONS

M Series Fan Filter Units

CWR265SZ 26 Bottle Built-in Wine Cooler Owner s Manual

T-SERIES Air Conditioner. T53 Model INSTRUCTION MANUAL nvent Rev. G P/N

THE CHATEAUX 52"/60" UNI PACK CEILING FAN INSTALLATION INSTRUCTIONS

10810 W. LITTLE YORK RD., STE. 130 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

Miniature Thermoelectric Cooler Controller MTCC-01 user's guide

Installation & Operation Manual Ice Cream Freezers

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL. Rev. E 2013 Pentair Equipment Protection P/N

GENESIS Air Conditioner. M52 3-Phase Model INSTRUCTION MANUAL. Rev. H 2013 Pentair Equipment Protection P/N

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

THERMAL SYSTEMS, INC. Installation and Operation Manual

INSTRUCTION MANUAL. T-SERIES Air Conditioner. T29 Model Pentair Equipment Protection P/N McLean Parts 5736 N. Michigan Rd.

MaxLite Polygon Linear LED Light

INSTALLATION USE & CARE MANUAL ALL WEATHER W-SERIES AND WD-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER

OPERATION MANUAL MODEL 4610 ACCELEROMETER

SUTTON 52 CEILING FAN

Part No Revised November / Instruction Manual Model #8150 AND #8151

Part No Revised December 2002 DESIGNER SERIES NACHO CABINETS Instruction Manual Model #5510, 5511 AND 5512

InstructIon Manual KrEs EQuIPMEnt stands

THE CAPRI III CEILING FAN INSTALLATION INSTRUCTIONS

Thermoelectric Assembly

Controlled Energy Corp. 340 Mad River Park Waitsfield, VT TOLL FREE

THE ALTON CEILING FAN INSTALLATION INSTRUCTIONS

THE DAVENPORT CEILING FAN INSTALLATION INSTRUCTIONS

SPECTRACOOL Air Conditioner

Service Manual Models CPH2 & CPH3

Part No Revised November 2004 DESIGNER SERIES NACHO CABINETS Instruction Manual Model #5513

THE VALOR CEILING FAN INSTALLATION INSTRUCTIONS

DBF 4XL Dryer Booster Fans

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP

ProAir CR43 INSTRUCTION MANUAL FOR: McLean Thermal Business Park Blvd. N Champlin, MN Tel: Fax:

WATLOW IND. WATROD Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2.00

The Monaco Patio. Please read and save these instructions

T-Series Air Conditioner

OPERATION MANUAL Model 8011 & mA

ProAir CR29 INSTRUCTION MANUAL FOR: McLean Thermal Business Park Blvd. N Champlin, MN Tel: Fax:

Air Storm Fans. Air Storm 18 Fiberglass Fan Installation and Operation Manual

THE GUSTO CEILING FAN INSTALLATION INSTRUCTIONS

DUAL VOLTAGE REFRIGERATORS 220/240 VOLTS AC AND 12/24 VOLTS DC INSTALLATION AND OWNER S MANUAL

OPERATION MANUAL MODEL 8102 ACCELEROMETER

Instruction Manual. Cheese Warmer with Pump

Model 2016, 2025, 2025BN, 2025ST Staging Cabinets Instruction Manual

48 TAYLOR CEILING FAN

Preamplifier Power Supply PPS-02 user's guide

FLCH4R Garage and Utility Electric Heater

THE LIBERTY CEILING FAN INSTALLATION INSTRUCTIONS

Installation and Operations Manual

DUVAL 52 CEILING FAN MODELS #50201, Español p. 19 LISTED FOR DAMP LOCATION

AMERICA AMERICA 52 CEILING FAN INSTALLATION AND OPERATION MANUAL

Turbo Air Speed up the Pace of Innovation TBB-4SB CAUTION! PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT

Model R060 Installation - Operation Manual

Part Number DOMESTIC. HyPerSteam Atmospheric Convection Steamer BETA 1.0

Silicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL. Rev. B 2016 Pentair Equipment Protection P/N

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

Transcription:

AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL

Table of Contents Introduction 3 Incoming Inspection 3 General Safety & Warnings 3 Technical Specifications 4 Installation and Operation Instructions 6 Serviceability 9 Warranty 9 Return Procedure 10 Americas: +1.919.597.7300 Europe: +46.31.420530 Asia: +86.755.2714.1166 www.lairdtech.com ets.sales@lairdtech.com 2 www.lairdtech.com

Introduction Laird Outdoor Cooler Series is an Air to Air thermoelectric assembly that uses impingement flow to transfer heat. It offers dependable compact performance by cooling objects via convection and is designed to provide cooling for a wide range of outdoor environments in the telecom, industrial and kiosk markets. They are intended to work in an open loop system or if purchased with a bi-directional controller in a closed loop system with feedback control. Heat is absorbed and dissipated thru high density heat exchangers equipped with air ducted shrouds and brand name fans. The heat pumping action occurs from custom designed thermoelectric modules that achieve a high coefficient of performance (COP) to minimize power consumption. This product series has been designed to pass rigorous Telcordia test requirements for outdoor environments. This is due to the selection of world class components such as brand fans with the highest degree of environmental protection, waterproof connectors, heavy duty anodization on the heat exchangers, and double environmental seals for the thermoelectric modules. This manual provides the necessary general information for proper installation and operation that has been developed to achieve the best results when using a Laird Outdoor Cooler Series product. Incoming Inspection Laird Outdoor Coolers are designed, built, and packaged to withstand the shock and vibration associated with normal transit means by common carriers. Occasionally, improper handling during shipment may cause damage to the product. Therefore, packages should be opened promptly and inspected for damage. Any packaging tears, dents, scratches, or loose objects should be noted on the Freight Bill. If damage is found, an immediate claim must be filed with the freight carrier. Retain all packing materials. Laird cannot be responsible for Consignee s failure to file a freight claim in a timely manner. General Safety & Warning WARNING Electrical Shock Hazard INSTALL UNIT TO CABINET WALL FIXTURE PRIOR TO POWERING DEVICE. OPERATIONAL VOLTAGE SHOULD COMPLY TO NOMINAL RATING ON LABEL. ENSURE THAT THERE IS AN EXTERNAL FUSE IN LINE WITH OUTDOOR COOLER TO PROTECT INPUT POWER LINES TO UNIT 3 www.lairdtech.com

Technical Specifications Laird TEA product nomenclature can be defined as follows: HEAT TRANSFER COOLING POWER VOLTAGE FANS TEMPERATURE CONTROLLERS AA (Air to Air) 100 Watts 150 Watts 200 Watts 250 Watts 480 Watts 24 VDC 48 VDC IP 44 IP 54 00-XX Open loop, no temperature control LE-XX Closed loop, thermostatic control (cooling mode > 35C, heating mode < 5C) LK-XX Closed loop, thermostatic control (cooling mode > 25C, heating mode < 10C) Consult with Laird for custom designed bi-directional control features, alarms or self start checks. Specifications The below specification table shows ratings for a standard AA-480 Outdoor Cooler unit with operation at either 24 VDC or 48 VDC. Technical Technology Cooling at dt = 0 C, and nominal / float voltage.1 Heating 2 Thermoelectric modules, forced air, closed loop (not mixing with outside air), filter-less, non-refrigerant 480/529W (1638/1805 Btu/hr) 450W (1535 Btu/hr) Voltage (nominal / maximum) 24/28 VDC 48/60 VDC Current draw, ±10% (nominal) 19.3 Amps 9.7 Amps Grounding (all voltages) Weight Panel mounting Fan life (L10 at +40 C) Connector type Hi-pot testing Environmental Temperature range 3 (external ambient) Temperature range (internal enclosure) Degree of protection, enclosure 4 Degree of protection, unit 5 Sound level (1m distance) Over-Temp Thermostat (hot and cold side heat sink) - Positive or negative 13.2 kg (29.1 lbs) Through mount Cold side 57,500hr, Warm side 75,000hr Terminal block with cage clamp (12-28 AWG) 707 VDC -40 C to +55 C (-40 F to +131 F) -20 C to +55 C (-4 F to +131 F) NEMA 4 (IP55) IP54 65 db(a) 1) Cooling capacities at nominal / float voltage are rated at external temperatures of 35 C and 50 C respectively. Float voltage is defined at 28 VDC for 24 volt version or 54 VDC for 48 volt version. 2) Heating capacity is rated at external temperature of -40 C, nominal voltage, and ΔT = 45 C. 3) Controller function should not operate the external fan during heating mode. This will pull heat out of the cabinet. 4) The highest environmental protection level requires an external shroud and is defined as the protection level for the enclosure. 5) Rating for unit without protective shroud. Note: The specified performance of any Laird cooling unit is dependent on how it is handled and incorporated into the final product. This includes elements such as the system design, insulation design, and assembly method. While Laird is able to provide general guidelines based upon our experience, it is ultimately the responsibility of the OEM to validate each product and its performance for its intended use. 4 www.lairdtech.com

Performance Curve The cooling capacity was conducted at an ambient temperature of 35 C. Performance will deviate based on ambient temperature condition. PERFORMANCE Pc VS ΔT 600 500 400 Pc (W) 300 200 100 0 0 5 10 15 20 25 30 35 40 ΔT ( C) Isometric Drawing 171.4 303 57.6 306 330 122.1 59.3 43.9 280 3 Sealing gasket Sealing gasket 5 www.lairdtech.com

Installation and Operation Instructions Reducing the passive heat load is critical to yield the highest efficiency out of an Outdoor Cooler and maximize service life. It is important to insulate the walls of an enclosure with as much insulation material as permissible without interfering with nearby electronics or system level obstructions. Proper insulation of the enclosure can result in sizing a smaller Outdoor Cooler unit and power supply, which can reduce total system costs. The Outdoor Cooler is mounted onto a cabinet wall with Hot Side mounted external to cabinet. This is required to dissipate heat out of the cabinet. It is also important to have good ventilation on the hot side to transport heat exhaust away from the cabinet. At minimum of one fan thickness is required from the wall surface to the exterior face of the fan to allow air to enter into the fan and transport the exhaust through the ducted shroud. Outdoor Coolers cool below ambient, so it is important to run them in a cabinet that is sealed from the outside environment. If the dew point is reached, then moisture in the air will condense onto the cold side heat exchanger. Access to outside air exchange can accelerate the moisture condensation rate and cause large amounts of moisture to accumulate on the cold surfaces of the Outdoor Cooler, which could degrade operation life over time if the system is not designed to drain condensation. It is recommended to mount the Outdoor Cooler in a vertical orientation, so condensation runs off the cold side heat exchanger. If the enclosure cannot accommodate this, then the Outdoor Cooler should be installed at a minimum 15 degree angle in horizontal orientation to allow for condensation to run off the cold side heat exchanger. The Outdoor Cooler must be protected from vandalism or external forces that may bump up against unit and cause damage. Mounting & Hardware The enclosure should be sealed from the outside environment by maintaining good compression between the Outdoor Cooler and cabinet wall. The Outdoor Coolers are designed to be through mount, so a cut out on the enclosure wall will be required to accommodate the cold side heat exchanger. Reference the below diagram for mounting hole locations and cold side heat exchanger dimensions. The cut out should be 2.5 mm s larger than the cold side heat exchanger. Eight mounting holes are available to fasten the Outdoor Cooler unit to cabinet wall. The mounting holes are designed to accommodate M5 machine hardware as shown in diagram. External tooth lock washers are recommended to prevent Outdoor Cooler from loosening over time. 6 www.lairdtech.com

Sealing gasket 330 96 Φ5.5 (8x) 280 316 306 306 TE-unit Machine screw Cabinet wall Tooth washer Flat washer Nut 7 www.lairdtech.com

Schematic Outdoor Coolers come with a durable simple to use cage clamp. Wires should be stripped back 6 mm s in length and inserted into connector. Connector can accommodate wire sizes of 12 to 28 AWG. For input power to TEM 16 AWG stranded copper wire is recommended. For input power to fans 18 AWG stranded copper wire is recommended. Internal schematic of Outdoor Cooler Unit. (24 Volt schematic shown) 1. Connect external fuse in line with input power connector to protect input power lines from shorting. 2. Input voltage must not exceed rating on label of unit. Maximum ripple current should not exceed three percent of nominal value. 8 www.lairdtech.com

Serviceability No special maintenance is required when using Laird Outdoor Coolers. For continued optimal performance and extended life of the unit, it is recommended to clean the (internal/external) heat sinks and fans periodically as they will accumulate dust from outside contaminants over time. If a unit is not performing properly consult with Laird. Warranty Laird Outdoor Coolers are manufactured in an ISO 9001:2008 facility. Units adhere to the highest quality standards and are free from defects in material, components, and workmanship. This warranty covers repair or replacement of product, to be done at a Laird facility, for a period of two (2) years from date of shipment. Customer is responsible for shipping product to Laird freight prepaid. Laird in turn will return the warranted product to customer freight prepaid, if within the time period specified above. Warranty coverage is in effect when the following operating conditions are continuously satisfied: Ambient Temperature Range within -40 C to 55 C. Line Voltage variation within plus or minus 10% of nameplate rating. In addition, the following criteria must be met: Electrical installation and grounding must comply with local electrical and safety codes. Outdoor Cooler must be used in the environment for which it is designed. Customer cannot abuse or mishandle the product in any way. Any modifications to the original unit will also void warranty. Compliance to User s Manual or any other instructional guide provided by Laird for the product. This warranty does not cover the following: Applications where product is being misapplied. This includes inappropriate selection of Outdoor Cooler for the environment and conditions in which it is to be used. Damages caused by shipping carrier or any other accident after product has left Laird. Shipping claims are the responsibility of the customer and are to be completed in a timely manner. Reimbursement of labor for installation or removal of warranted product, or for parts and labor resulting from repairs performed by any other source besides Laird. This is the complete warranty and is in lieu of any other warranty expressed or implied, including but not limited to any implied warranty of merchantability or fitness for a particular purpose. Laird will in no way be liable for incidental or consequential damage whatsoever or for any other claims by the customer for damages in connection with Laird products, even if advised in advance of the possibility of such damage. 9 www.lairdtech.com

Return Procedure All returns must be assigned a Non-Conformance Material Return Authorization number (NCMR#) in advance. Returns received without RMA # may be refused. In the event that a return is required, the Customer should call Laird Customer Service Department at USA: +1.919.597.7300, Europe: +46.31.420530, Asia: +86.755.2714.1166 or send an email to order.gothenburg@lairdtech.com. The Customer will be asked to fill out an NCMR form so that NCMR number can be issued. All returns must be securely packed to prevent shipping damage and must be clearly marked with the NCMR number on the box. Consignor shall pay freight charges on all returns. 10 www.lairdtech.com

Americas: +1.919.597.7300 Europe: +46.31.420530 Asia: +86.755.2714.1166 www.lairdtech.com order.gothenburg@lairdtech.com Any information furnished by Laird and its agents is believed to be accurate and reliable. All specifications are subject to change without notice. Responsibility for the use and application of Laird materials rests with the end user, since Laird and its agents cannot be aware of all potential uses. Laird makes no warranties as to the fitness, merchantability or suitability of any Laird materials or products for any specific or general uses. Laird, Laird Technologies, Inc or any of its affiliates or agents shall not be liable for incidental or consequential damages of any kind. All Laird products are sold pursuant to the Laird Terms and Conditions of sale in effect from time to time, a copy of which will be furnished upon request. Copyright 2015 Laird Technologies, Inc. All Rights Reserved. Laird, Laird Technologies, the Laird Logo, and other marks are trademarks or registered trademarks of Laird Technologies, Inc. or an affiliate company thereof. Other product or service names may be the property of third parties. Nothing herein provides a license under any Laird or any third party intellectual property rights.