Upflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

Similar documents
Downflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

Upflow/Horizontal Condensing, Gas-Fired Furnace

Downflow/Horizontal Right Induced Draft Gas Furnace

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Downflow/Horizontal Right or Downflow/Horizontal Left Induced Draft Gas Furnace

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XB 80 TDD-D-1 PUB. NO

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Upflow/Downflow Horizontal Right or Left Gas-Fired Furnace

XC80 TUD2B060ACV32A TUD2B080ACV32A TUD2C080ACV42A TUD2B100ACV32A TUD2C100ACV52A TUD2D120ACV52A TUD2D140ACV52A

Upflow/Horizontal Left Downflow/Horizontal Right Condensing, Direct Vent Gas-Fired Furnace FREEDOM 90 SINGLE STAGE

Upflow/Horizontal Left, Downflow/Horizontal Right Two Stage Condensing Gas-Fired Furnace

Upflow/ Horizontal Left, Downflow/ Horizontal Right Two Stage Condensing Gas-Fired Furnace XL 90

XV80i. Upflow/Horizontal 80% 2-Stage, Variable Speed Gas-Fired Furnace with Whole House Air Cleaner PUB. NO

Upflow/Horizontal 2-Stage, Communicating Variable Speed Gas Furnace Platinum SV

Upflow/ Downflow Horizontal Right or Left Gas-Fired Furnace

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U4-SUB-1-EN. February 2016 S9V2B080U4PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 40,000 BTUH S9V2B040U3-SUB-1-EN. February 2016 S9V2B040U3PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U3-SUB-1-EN. February 2016 S9V2B080U3PSAA TAG:

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 100,000 BTUH S9V2C100D4-SUB-1-EN. March 2016 S9V2C100D4PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 100,000 BTUH S9V2C100U4PSBA TAG:

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080D3PSBA TAG:

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 60,000 BTUH S9V2B060D3PSBA TAG:

Upflow/ Horizontal Left/Right, Downflow Two Stage Condensing Gas Fired Furnace

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

X341119P10 Gas Furnace Var. Speed Blower Var. Speed Inducer Two Stage Heat Direct Vent Models:

SERVICE FACTS WARNING M801-SF-1C. Gas Furnaces Upflow & Downflow Induced Draft 1 Stage Heat Models: DISCONNECT POWER BEFORE SERVICING M801P040AU24AA

80% and 95% furnace models feature aluminized steel heat exchangers to conduct heat quickly and increase durability.

PRODUCT SPECIFICATIONS 1 *UH2B080A942VA

*DD2B060A9V3VA *DD2B080A9V3VA *DD2C100A9V5VA *DD2D120A9V5VA

MERIT SERIES Downflow

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

13 GEP A L P - 1 A

TECHNICAL SPECIFICATIONS

FG7T (C and L Series)

Upflow/ Horizontal Left/Right, Downflow Single and 2 Stage Non-Condensing Gas Fired Furnace

G6RC Series TECHNICAL SPECIFICATIONS

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

GMS95 GAS $AVER PRODUCT SPECIFICATIONS 95% AFUE. Multi-Position, Single-Stage/Multi-Speed Gas Furnace. Heating Capacity: 46, ,000 BTUH

Vertical Upflow Horizontal Left Air Handlers

GME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL

FORM NO. G REV. 2 Supersedes Form No. G Rev. 1 GAS FURNACES

TECHNICAL SPECIFICATIONS

GMS9/GCS9 SERIES 93% AFUE

RG7D 1-Stage Heat Series

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

36,000-62,000 BTUH Nominal Capacity

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers

ELITE SERIES Downflow - High Efficiency Blower Motor

ADSH8. Two-Stage Convertible. Heating Input: 40, ,000 BTU/h

TECHNICAL SPECIFICATIONS

Multi-Position Gas Furnaces

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

RGE 13 A T - 1 A

GAS FURNACES. RGRK- SERIES Models with Input Rates 120,000 BTU/HR [35.17 kw] (All Models 90% A.F.U.E. or Above)

TECHNICAL GUIDE MODELS: P*UR GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 92 AFUE DESCRIPTION WARRANTY FEATURES Rev.

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

80% AFUE. Multi-Position, Dual$aver. Heating Input: 70, ,000 BTU/h

Modular Multi-position Air Handler

Ruud Achiever Plus Series Multi-position Gas Furnaces

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3

COMFORT CONTROL 90 PLUS WITH DUAL TWO-STAGE UPFLOW GAS FURNACES

Cooling Capacity CFM in. w.c. (125 Pa)

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

GMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace

8+* Bulletin No November 1997

Product Data. 58PAV Energy-Efficient Induced-Combustion Upflow Furnace. Input Capacities: 45,000 thru 155,000 Btuh. 80% AFUE At Budget Price

Wt. Lbs Model Number (BTUH) Hz

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications

Series Two- Stage Multi-position Gas Furnaces. Ruud Achiever Plus. R96T- Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33.

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

MULTI POSITION GAS FURNACE

TZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. )

TZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 95% A.F.U.E. )

395CAV Sizes 045 thru 155 Series H and J

W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. )

Ruud Achiever Series Multi position Gas Furnaces

Cooling Capacity CFM in. w.c. (125 Pa)

GAS FURNACES SUPER QUIET 80 TWO STAGE 80% A.F.U.E. DOWNFLOW GAS FURNACES

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

MULTI POSITION GAS FURNACE

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES

Rheem Classic Series Multi-position Gas Furnaces

TZ96MDV SERIES Model with Input Rates from 60 to 100 kbtu [17.58 to kw] (All Models 95% A.F.U.E. )

Cooling/Heat Pump Convertible Air Handlers

GAS FURNACES 90 PLUS WITH DUAL COMFORT CONTROL TWO-STAGE UPFLOW GAS FURNACES

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

Cooling Capacity CFM range

Gas Furnaces. Gas Furnaces. 2-Stage Variable-Speed. 2-Stage Multi-Speed Multipoise. Multipoise 80AFUE. 2-Stage Variable-Speed Multi-Speed Multipoise

SL280DFV. DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

Transcription:

Upflow/Horizontal Condensing, Gas-Fired Furnace XB 90 TUC1B00A921A, TUC1B060A9361A TUC1B080A921A, TUC1C100A981A TUC1D100A9601A, TUC1D1A9601A Single-Stage Fan Assisted Combustion System PUB. NO. 22-1669-15

General Features NATURAL GAS MODELS Central Heating furnace designs are certified by the American Gas Association for both natural and L.P. gas. Limit setting and rating data were established and approved under standard rating conditions using American National Standards Institute standards. SAFE OPERATION The Integrated System Control has solid state devices, which continuously monitor for presence of flame, when the system is in the heating mode of operation. Dual solenoid combination gas valve and regulator provide extra safety. QUICK HEATING Durable, cycle tested, heavy gauge aluminized steel heat exchanger quickly transfers heat to provide warm conditioned air to the structure. Low energy power vent blower, to increase efficiency and provide a positive discharge of gas fumes to the outside. BURNERS Multiport Inshot burners will give years of quiet and efficient service. All models can be converted to L.P. gas without changing burners. INTEGRATED SYSTEM CONTROL Exclusively designed operational program provides total control of furnace limit sensors, blowers, gas valve, flame control and includes self diagnostics for ease of service. Also contains connection points for E.A.C./humidifier. AIR DELIVERY The variable speed, direct drive blower motor, has sufficient airflow for most heating and cooling requirements, will switch from heating to cooling speeds on demand from room thermostat. The blower door safety switch will prevent or terminate furnace operation when the blower door is removed. STYLING Heavy gauge steel and wrap-around cabinet construction is used in the cabinet with baked-on enamel finish for strength and beauty. The heat exchanger section of the cabinet is completely lined with foil faced fiberglass insulation. This results in quiet and efficient operation due to the excellent acoustical and insulating qualities of fiberglass. Built-in bottom pan and alternate bottom, left or right side return air connection provision. FEATURES AND GENERAL OPERATION The XB 90 High Efficiency Gas Furnaces employ a Hot Surface Ignition system, which eliminates the waste of a constant burning pilot. The integrated system control lights the main burners upon a demand for heat from the room thermostat. Complete front service access. a. Low energy power venter b. Vent proving pressure switch. Trane 17 All rights Reserved 2 Pub. No. 22-1669-15

Contents Feature Summary Features and Benefits Standard Equipment Optional Equipment General Data TUC1B00A921A TUC1B060A9361A TUC1B080A921A TUC1C100A981A TUC1D100A9601A TUCAD1A9601A Performance Data Electrical Data Field Wiring Dimensions 2 5 7 8 10 11 Pub. No. 22-1669-15 3

Features and Benefits XB 90 STANDARD EQUIPMENT Power supply Upflow convertible to horizontal left Type 29-C TM stainless steel secondary heat exchanger Direct drive, -speed motor Silicon Nitride hot surface igniter with adaptive heat up Accessory hook-up capability- Hum & EAC Quiet induced draft blower Blower door safety switch Dual solenoid combination gas valve & regulator PVC venting - 1 Pipe Left/right gas connection Integrated solid state control with self-diagnostics Selectable cooling fan off delay eliminates need for BAY2X05 time delay relay 2 volt fuse Manual reset burner box limit Optional extended warranties XB 90 OPTIONAL EQUIPMENT Thermostat, Electronic, Non-programmable 1 Heating/1 Cool... TCONT0AN11AA [ ] Thermostat, Electronic Programmable 1-Stage Heating/1-Stage Cooling... TCONT800AS11AA [ ] Propane Conversion Kit...BAYLPKT210A [ ] Electronic Air Filter, Perfect Fit Super Efficiency (17-" Wide Gas Furnace)... TFE175A9FR0 [ ] Electronic Air Filter, Perfect Fit Super Efficiency (21" Wide Gas Furnace)... TFE210A9FR0 [ ] Electronic Air Filter, Perfect Fit Super Efficiency (2-" Wide Gas Furnace)... TFE25A9FR0 [ ] Electronic Air Filter, Perfect Fit High Efficiency (17-" Wide Gas Furnace)...TFM175A9FR0 [ ] Electronic Air Filter, Perfect Fit High Efficiency (21" Wide Gas Furnace)...TFM210A9FR0 [ ] Electronic Air Filter, Perfect Fit High Efficiency (2-" Wide Gas Furnace)...TFM25A9FR0 [ ] Electronic Air Filter, Perfect Fit Standard Efficiency (17-" Wide Gas Furnace)... TFP175A9FR0 [ ] Electronic Air Filter, Perfect Fit Standard Efficiency (21" Wide Gas Furnace)... TFP210A9FR0 [ ] Electronic Air Filter, Perfect Fit Standard Efficiency (2-" Wide Gas Furnace)... TFP25A9FR0 [ ] Coil Enclosure (17-" Wide Cabinets)...BAYCLE17A1722A [ ] Coil Enclosure (21" Wide Cabinets)...BAYCLE21A2130A [ ] Coil Enclosure (2-" Wide Cabinets)...BAYCLE2A230A [ ] Side Filter Rack...BAYFLTR0 [ ] High Altitude Switch...BAYHALT225 [ ] High Altitude Switch...BAYHALT226 [ ] High Altitude Switch...BAYHALT228 [ ] High Altitude Switch...BAYHALT20 [ ] Filter Kit Horizontal coversion TUC01B0,060,080C...BAYFLTR3 [ ] Filter Kit Horizontal coversion TUC1C100X98B...BAYFLTR [ ] Filter Kit Horizontal coversion TUC1D100C960, TUC1D1C...BAYFLTR5 [ ] Twinning Kit...BAYTWIN00A [ ] Wall Mount Flange-3"...BAY96X17 [ ] Wall Mount Flange-2"...BAY96X18 [ ] Horizontal Vent Cap (Noryl)...BAY96X16 [ ] Pub. No. 22-1669-15

General Data MODEL TYPE RATINGS 2 Input BTUH Capacity BTUH (ICS) 3 AFUE (Upflow / Horizontal) Temp. rise (Min.-Max.) F. BLOWER DRIVE Diameter - Width (In.) No. Used Speeds (No.) CFM vs. in. w.g. Motor HP R.P.M. Volts / Ph / Hz COMBUSTION FAN - Type Drive - No. Speeds Motor HP - RPM Volts / Ph / Hz FLA FILTER Furnished? Type Recommended Hi Vel. (No.-Size-Thk.) VENT Size (in.) HEAT EXCHANGER Type-Fired -Unfired Gauge (Fired) ORIFICES Main Nat. Gas. Qty. Drill Size L.P. Gas Qty. Drill Size GAS VALVE PILOT SAFETY DEVICE Type BURNERS Type Number POWER CONN. V / Ph / Hz Ampacity (In Amps) Max Overcurrent Protection (Amps) PIPE CONN. SIZE (IN.) DIMENSIONS Crated (In.) WEIGHT Shipping (Lbs.) / Net (Lbs) PRODUCT SPECIFICATIONS 1 TUC1B00A921A Upflow / Horizontal 0,000 37,000 92.1 / 91.3 30-60 DIRECT 9 x 7 1 See Fan Performance Table 1/5 1075 Centrifugal Direct - 1 1/55-3000 1.0 No High Velocity 1-17x25-1in. 2 Round Aluminized Steel - Type I 2 5 2 56 Redundant - Single Stage Hot Surface Ignition Multiport Inshot 2.7 15 H x W x D 1-3/ x 19- x 30-139 / 129 TUC1B060A9361A Upflow / Horizontal 60,000 56,000 92.1 / 91.3 30-60 DIRECT 10 x 7 1 See Fan Performance Table 1/3 1075 Centrifugal Direct - 1 1/55-3000 1.0 No High Velocity 1-17x25-1in. 2 Round Aluminized Steel - Type I 3 5 3 56 Redundant - Single Stage Hot Surface Ignition Multiport Inshot 3 8.3 15 H x W x D 1-3/ x 19- x 30-150 / 10 TUC1B080A921A Upflow / Horizontal 80,000 7,000 92.1 / 91.3 35-65 DIRECT 10 x 8 1 See Fan Performance Table 1/3 1075 Centrifugal Direct - 1 5-30 1.35 No High Velocity 1-17x25-1in. 2 Round Aluminized Steel - Type I 5 56 Redundant - Single Stage Hot Surface Ignition Multiport Inshot 9. 15 H x W x D 1-3/ x 19- x 30-158 / 18 1 Central Furnace heating designs are certified by ETL. 2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate % per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applicaitons, above input ratings (BTUH) are up to,500 feet, derate % per 1,000 feet for elevations above,500 feet above sea level. 3 Based on U.S. government standard tests. The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. Pub. No. 22-1669-15 5

General Data PRODUCT SPECIFICATIONS 1 MODEL TYPE RATINGS 2 Input BTUH Capacity BTUH (ICS) 3 AFUE (Upflow / Horizontal) Temp. rise (Min.-Max.) F. BLOWER DRIVE Diameter - Width (In.) No. Used Speeds (No.) CFM vs. in. w.g. Motor HP R.P.M. Volts / Ph / Hz COMBUSTION FAN - Type Drive - No. Speeds Motor HP - RPM Volts / Ph / Hz FLA FILTER Furnished? Type Recommended Hi Vel. (No.-Size-Thk.) VENT Size (in.) HEAT EXCHANGER Type-Fired -Unfired Gauge (Fired) ORIFICES Main Nat. Gas. Qty. Drill Size L.P. Gas Qty. Drill Size GAS VALVE PILOT SAFETY DEVICE Type BURNERS Type Number POWER CONN. V / Ph / Hz Ampacity (In Amps) Max Overcurrent Protection (Amps) PIPE CONN. SIZE (IN.) DIMENSIONS Crated (In.) WEIGHT Shipping (Lbs.) / Net (Lbs) TUC1C100A981A Upflow / Horizontal 100,000 9,000 92.1 / 91.3 35-65 DIRECT 10 x 10 1 See Fan Performance Table 1075 Centrifugal Direct - 1 1/ - 350 0.71 No High Velocity 1 - x25-1in. 2 Round Aluminized Steel - Type I 5 5 5 56 Redundant - Single Stage Hot Surface Ignition Multiport Inshot 5 13.6 H x W x D 1-3/ x 23 x 30-171 / 160 TUC1D100A9601A Upflow / Horizontal 100,000 93,000 92.1 / 91.3 35-65 DIRECT 11 x 10 1 See Fan Performance Table 3/ 1100 Centrifugal Direct - 1 1/ - 350 0.71 No High Velocity 1-2x25-1in. 2 Round Aluminized Steel - Type I 5 5 5 56 Redundant - Single Stage Hot Surface Ignition Multiport Inshot 5 13.9 H x W x D 1-3/ x 26- x 30-197 / 185 TUC1D1A9601A Upflow / Horizontal 1,000 113,000 92.1 / 91.3 0-70 DIRECT 11 x 10 1 See Fan Performance Table 3/ 1100 Centrifugal Direct - 1 1/ - 350 0.71 No High Velocity 1-2x25-1in. 3 Round Aluminized Steel - Type I 6 5 6 56 Redundant - Single Stage Hot Surface Ignition Multiport Inshot 6 12.9 H x W x D 1-3/ x 26- x 30-5 / 193 1 Central Furnace heating designs are certified by ETL. 2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate % per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applicaitons, above input ratings (BTUH) are up to,500 feet, derate % per 1,000 feet for elevations above,500 feet above sea level. 3 Based on U.S. government standard tests. The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. 6 Pub. No. 22-1669-15

Performance Data FURNACE AIRFLOW (CFM) VS. EXTERNAL STATIC PRESSURE (INS. w.g.) MODEL SPEED TAP 0.10 0. 0.30 0.0 0.50 0.60 0.70 0.80 0.90 TUC1B00A921A - 3-2 - 1 - HIGH - Black MED.-HIGH - Blue MED.-LOW - Yellow LOW - Red 103 90 837 729 992 895 798 69 930 81 752 657 885 791 705 600 812 726 69 55 70 650 560 78 67 559 38 376 518 305 2 157 90 79 78 TUC1B060A9361A - 3-2 - 1 - HIGH - Black MED.-HIGH - Blue MED.-LOW - Yellow LOW - Red 139 1250 1102 957 1359 1232 1092 9 131 12 1069 922 1260 1160 103 891 1196 1106 986 853 1122 100 925 806 1038 962 852 750 95 873 766 686 853 771 668 61 TUC1B080A921A - 3-2 - 1 - HIGH - Black MED.-HIGH - Blue MED.-LOW - Yellow LOW - Red 178 1375 1178 859 1683 1367 1167 863 1615 137 117 856 15 131 1119 839 170 1268 1082 811 1393 1210 1036 772 131 1139 982 723 1232 1056 919 663 117 960 87 592 TUC1C100A981A - 3-2 - 1 - HIGH - Black MED.-HIGH - Blue MED.-LOW - Yellow LOW - Red 5 1932 1762 1558 1980 1875 17 156 1906 1818 1677 1533 1826 176 1615 177 176 1673 1552 121 169 1577 163 1350 1551 181 1373 1278 128 1371 1266 1175 1305 1260 1158 1071 TUC1D100A9601A - 3-2 - 1 - HIGH - Black MED.-HIGH - Blue MED.-LOW - Yellow LOW - Red 211 2108 1772 180 2358 83 1759 177 230 58 175 17 2235 07 1723 158 2165 1956 1700 11 83 1893 1657 11 01 1829 1613 1386 1915 175 15 1327 1828 1679 175 1268 TUC1D1A9601A - 3-2 - 1 - HIGH - Black MED.-HIGH - Blue MED.-LOW - Yellow LOW - Red 25 2105 177 15 206 92 172 17 2358 78 1736 19 2310 5 17 10 2261 12 1703 130 218 1950 1677 100 2106 1887 1651 1369 17 1826 1593 1325 1928 1765 1535 1280 MODEL CFM VS. TEMPERATURE RISE Cubic Feet Per Minute (CFM) 600 700 800 900 1000 1100 10 1300 100 1500 1600 1700 1800 1900 00 2100 20 TUC1B00A921A 56 8 2 37 33 TUC1B060A9361A 56 50 5 2 39 36 TUC1B080A921A 61 56 51 8 2 TUC1C100A981A 6 60 56 52 9 6 2 TUC1D100A9601A 6 60 56 52 9 6 2 0 38 TUC1D1A9601A 63 59 56 53 50 8 6 Pub. No. 22-1669-15 7

Electrical Data SCHEMATIC DIAGRAMS FOR GAS FURNACES From Dwg. D35803P01 Rev. A 8 Pub. No. 22-1669-15

Electrical Data SCHEMATIC DIAGRAMS FOR GAS FURNACES From Dwg. D35803P01 Rev. A Pub. No. 22-1669-15 9

Field Wiring FIELD WIRING DIAGRAM FOR HEATING ONLY FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING/COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) From Dwg.. 21B30387 Rev. 1 From Dwg.. 21B30388 Rev. 1 10 Pub. No. 22-1669-15

Dimensions 1-3/ X 2-13/32 CUTOUT HORIZONTAL DRAIN Ø 7/8 HOLE WITH PLUG CONDENSATE DRAIN TUC1 OUTLINE DRAWING (ALL DIMENSIONS ARE IN INCHES) 22-11/16 Ø 1-5/8 HOLE WITH PLUG Ø 1-5/8 HOLE WITH PLUG 28-1/ Ø 7/8 HOLE WITH PLUG CONDENSATE DRAIN (ALTERNATIVE) Model (See Note 1 & 2) *UC1B00A921 *UC1B060A9361 *UC1B080A921 DIM "A" DIM "B" DIM "C" DIM "D" DIM "E" DIM "F" 17-" 2-1/" 16-1/" 16" 7-" 2" *UC1C100A981 21" 2-" 19-3/" 19-" 9" 3" *UC1D100A9601 2-" 2-15/16" 23-1/" 23" 10" 3" *UC1D1A9601 * Prefix may be "A" or "T" Notes: 1. *UC1D1A9601 requires 3" diameter vent pipe. 2. *UC1C100A981 & *UC1D100A9601 requires 2-" or 3" diameter vent pipe. 3. Diameter of Vent Pipe may be limited to 2-" or 3" on some models at different altitudes. Refer to the Vent Length Table for proper application. Pub. No. 22-1669-15 11

Trane 60 Troup Highway Tyler, TX 75707 Since Trane has a policy of continuous product and product data improvement, it reserves the right to change design and specifications without notice.