THERMAL MANAGEMENT SOLUTIONS

Similar documents
THERMAL MANAGEMENT SOLUTIONS

ECW-GF, ECW-GF-DP DIGITAL ELECTRONIC CONTROLLERS AND REMOTE DISPLAY PANEL PRODUCT OVERVIEW

C SINGLE-POINT HEAT-TRACING CONTROL SYSTEM. product overview

C910 Series. Single-point heat-tracing control system

JBS-100-ECP-A COMBINATION POWER CONNECTION BOX AND DIGITAL ELECTRONIC CONTROLLER INSTALLATION INSTRUCTIONS

910 Series Single-point heat-tracing control system

Dual-point heat-tracing control system

JBS-100-EC Electronic controller replacement kit for JBS-100-ECP-A and JBS-100-ECW-A Installation Instructions

C SINGLE-POINT HEAT-TRACING CONTROL SYSTEM PRODUCT OVERVIEW

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Above Ground Greasy Waste Disposal Lines

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Aboveground Fuel Oil Lines

CSI Master Format 2004 Guide Specification for: Snow Melting (Mineral Insulated)

CSI Master Format 2004 Guide Specification for: Freezer Frost Heave Prevention (Mineral Insulated)

FreezGard. Self-regulating crankcase heater. Product Overview

920 Series. A dry contact relay is provided for alarm annunciation back to a distributed control system (DCS).

ACS-30 MULTIPOINT COMMERCIAL HEAT-TRACING SYSTEM PRODUCT OVERVIEW. ACS-30 System

CSI Master Format 2012 Guide Specification for: Hot Water Temperature Maintenance (HWAT) Systems

NGC-40 Advanced Heat-Tracing Control System

Freezer Frost Heave Prevention

ACCS-30. Multipoint commercial heat-tracing control system

HTC-915-CONT. Heat-Trace Control system

SMPG3 SNOW MELTING AND DE-ICING POWER DISTRIBUTION AND CONTROL PANEL. For three-phase heating cables PRODUCT OVERVIEW

FTC-HST WARNING: CAUTION:

NGC-UIT2-ORD-R Remote User Interface Terminal for Raychem NGC Systems Installation Instructions

NGC-UIT2 MODBUS PROTOCOL INTERFACE MAPPING FOR NGC-30 SYSTEMS. Firmware versions up to V2.0.X

For Raychem ACS-30 Controls Systems

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

NGC-UIT-ORD User interface terminal for Raychem NGC systems Installation Instructions

COMMERCIAL HEAT TRACING PRODUCTS AND SERVICES

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

XL-Trace System Application and Design Guide

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

NGC-40-IO Control and monitoring modules for use with the Raychem NGC-40 system Installation Instructions

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

Pipe Freeze Protection. Flow Maintenance. Introduction. XL-Trace System

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

DESCRIPTION. 42 mm. 125 mm

DESIGN GUIDELINES. THERMAL building SOLUTIONS

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm

SAFETY INFORMATION AND WARNINGS

SMPG1 SNOW MELTING AND DE-ICING POWER DISTRIBUTION AND CONTROL PANEL FOR SINGLE-PHASE HEATING CABLES PRODUCT OVERVIEW

ACS-30-EU-EMDR- 10-MOD

JB-RTD-STAND RTD PIPE STAND FOR COMBINATION POWER CONNECTION BOX AND ELECTRONIC CONTROLLER INSTALLATION INSTRUCTIONS

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

RAYCHEM NGC-30 COMPONENTS

C Heat Trace Controller

Factory and Field Installed Splices

HWAT -ECO. Installation and Operation Manual. Electronic controller for hot water temperature maintenance systems

ROOF AND GUTTER DE-ICING ICESTOP SYSTEM

XL-Trace System. Installation and Operation manual for pipe freeze protection and flow maintenance

HOT WATER TEMPERATURE MAINTENANCE HWAT SYSTEM

IceStop System INSTALLATION AND OPERATION MANUAL FOR ROOF AND GUTTER DE-ICING SYSTEMS

FIRE SPRINKLER SYSTEM FREEZE PROTECTION XL-TRACE SYSTEM

TOUCH 1500 User Interface Terminal for Raychem NGC Systems Installation Instructions

Longline Heating. Contents. Introduction

Roof and Gutter De-Icing

Sensor Interface Module Installation/Operation Instructions

TraceNet ECM Series Control System

Frost Heave Protection System Installation and Operation Manual

Design Guide Design Notes Design Examples Technical Data Sheets Expanded Capabilities Specifications Warranty

Hot Water Temperature Maintenance. HWAT System. Product Selection and Design Guide

ACS-30-EU-VIA-DU-20-MOD

Skin-Effect Heat-Tracing System (STS)

Dräger PointGard 2100 Detection of toxic gases and vapours

Ramsey Motion Monitoring Systems

NGC-20-C-E and NGC-20-CL-E

Cimco Series 21. Series 21 - Specifications INDEX. Description. Operational Specification 2

1SC-SSC Splice Connection Kit Installation Instructions

COMMERCIAL & RESIDENTIAL SELF-REGULATING HEATING PRODUCTS APPLICATION AND DESIGN GUIDE EUROPE, MIDDLE EAST, AFRICA

NGC-20-C-E and NGC-20-CL-E

HHS-WWH HOPPER HEATING SYSTEM WRAP-WOUND HEATER INSTALLATION INSTRUCTIONS DESCRIPTION. HHS-WWH PRODUCT SPECIfICATIONS

ROOF ICE MELT (RIM) SYSTEM

MODEL SST 2 40 FREEZE PROTECTION THERMOSTAT MODEL SST FIXED SET POINT THERMOSTAT. Installation and Operation Manual

PACSystems* RX3i. Thermocouple Input Module, 12 Channels, IC695ALG412. GFK-2578B October 2011

Installation Instructions DTC-24 SNOw MELTING &

Ramsey Series Motion Monitoring Systems Accurate Sensing of Speed Conditions on Rotating Shafts and Machinery

DigiTrace C910 Series Heat Trace Controller Installation, Operation, and Maintenance Manual

Installation and Operation Manual

Module Features are-configurable, no module jumpers to set

Thermo Scientific Ramsey TM Series Sensing Speed Conditions on Rotating Shafts and Machinery

sulfur transport pipelines Safe, Reliable and Cost-Effective Heat Management System

Fax (724) Main St.; P. O. Box 248 West Middlesex, PA IMPORTANT NOTICE

NELSON CM HEAT TRACE CONTROLLER Installation and Operating Instructions

Motogard. Over Temperature Protection System. Installation Instructions

Touchpoint 1. The Touchpoint 1 controller provides 24 hour protection from flammable, toxic or Oxygen gas hazards.

ADDITIONAL INFORMATION

T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability

DTC-24 SNOW MELTING & ROOF DE-ICING CONTROLS

Dual Input ph/orp Analyzer

T7984 A,B,C Electronic Modulating Control Thermostats

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

Dual Input Toroidal Analyzer

TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm

CLEANROOM MONITOR CR3A Network - Installation Instructions

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Transcription:

DIGITAL ELECTRONIC CONTROLLERS AND REMOTE DISPLAY PANEL ECW-GF with FTC-PSK pipe stand and power connection kit ECW-GF using RayClic power connection kit ECW-GF-DP remote display panel available only with ECW-GF ECW-GF-DP PRODUCT OVERVIEW The DigiTrace ECW-GF electronic controller provides accurate temperature control with integrated 30-mA ground-fault protection. The ECW-GF is ideal for pipe freeze protection, flow maintenance, freezer frost heave, floor heating and snow melting applications. The ECW-GF is housed in a NEMA 4X enclosure designed to be wall mounted or installed on a pipe with the optional Raychem FTC-PSK pipe stand kit. The controller includes a window and a digital display that shows the measured temperature, set point temperature and alarm conditions (temperature sensor failure, high or low temperature and ground-fault) if detected. Alarm conditions can be indicated via a Form C dry contact connected to a building management system. Status LEDs indicate whether the digital display is showing the set point or actual temperature or if the controller is in an alarm state. The ECW-GF can be programmed to maintain temperatures up to 200 F (93 C), at voltages from 100 to 277 V, and is capable of switching current up to 30 amperes. Programming the set point temperature, deadband, and the high and low alarm thresholds on the controllers is accomplished using the built-in digital display and push buttons. A 9-V battery connector is supplied to allow programming the controller before the heating cable circuit power is provided. ECW-GF using a separate junction box An optional remote display panel, the DigiTrace ECW-GF-DP, is available. This remote display provides remote alarm indication and ground-fault test and reset capability. The ECW-GF-DP can be installed indoors in a standard duplex box located up to 328 ft (100 m) from the controller. The ECW-GF is supplied with a 25-foot thermistor for line, slab or ambient sensing temperature control. 1 / 5

www.tycothermal.com ECW-GF, ECW-GF-DP ECW-GF CONTROLLER Display Menu Battery connection Remote display panel (ECW-GF-DP only) Thermistor terminals Alarm terminals ECW-GF without wire cover Wire cover Lid Wall mounting holes (typical 4) Actual temp LED Set point temp LED Next, Up, Down Heating cable power terminals Ground terminal Incoming power terminals MENU TEMPERATURE ACTUAL SETPOINT Hold 3 Seconds Next Up Down Hold for GF GF TEST Reset Battery Connector Menu Settings: Display: Alarms and Status Units ( F or C) Ground-fault test mode Set Point Ground-fault circuit failure Dead Band Ground-fault cable fault High Temp Alarm Shorted or open sensor Low Temp Alarm Remote panel comm failure Remote GF Panel High temp alarm Low temp alarm WARNING Shock Hazard ECW-GF Do not remove cover while energized Digital Controller Ne pas enlever le couvert tant que le with Ground-Fault Protection régulateur est sous tension 6.3 in (160 mm) Temperature ECW-GF Digital electronic controller with equipment ground-fault protection Type 4X Input: 100-277 Vac, 50/60 Hz, 30 A Output: 100-277 Vac, 30 A 80BJ Maximum Ambient: 140 F (60 C) Enclosed Energy For maintaining temperatures up to 200 F (93 C) Management Equipment in nonhazardous locations. Equipment Ground-Fault Protection: 30 ma Use only with Raychem, XL-Trace, RaySol and IceStop heating cables and Pyrotenax MI heating cables. Actual Setpoint Stand-offs Note: Next button is used for ground-fault test. Down button is used for ground-fault reset. 6.3 in (160 mm) GENERAL Approvals Nonhazardous locations Supply voltage 100 277 Vac ±10% 50 60 Hz Common supply for controller and heat tracing circuit ENCLOSURE Protection Material Entries Relative humidity Ambient installation and usage temperature NEMA 4X Fiberglass reinforced polyester plastic 1 x 3/4 in (19 mm) conduit entries for power 1 x 1 in (25 mm) conduit entry for heating cable 1 x 1/2 in (13 mm) conduit entry for RTD sensor 0% to 90%, noncondensing 40 F to 140 F ( 40 C to 60 C) CONTROL Relay type Control range Deadband Accuracy Double-pole, mechanical 32 F to 200 F (0 C to 93 C) Adjustable 2 F to 10 F (2 C to 6 C) ±3 F (1.7 C) of set point INPUT POWER Voltage Current 277 Vac nominal, 50/60 Hz maximum 30 A maximum MONITORING AND ALARM OUTPUT Temperature RTD failure Alarm relay Low alarm range: 20 F ( 6 C) to set point minus deadband, or OFF High alarm range: Set point plus (Deadband +5 F (3 C)) to 230 F, or OFF Shorted or open temperature sensor Form C: 2 A at 277 Vac, 2 A at 48 Vdc 2 / 5 EN-DigiTraceECWFamily-DS-H58338 01/13 THERMAL MANAGEMENT SOLUTIONS

TEMPERATURE SENSOR (INCLUDED) Input type Thermistor 10K ohm @25C Type J GROUND-FAULT Ground-fault protection Ground fault trip reset Ground-fault test 30 ma fixed Reset button, manual Manual ground-fault circuitry test; automatic hourly circuitry test PROGRAMMING AND SETTING Method Programmable at controller Push buttons on front panel Units F or C Digital display Four numeric display digits for parameter and error/alarm indication LEDs Indicate actual and set point from display and alarm state Memory Nonvolatile, restored after power loss Stored parameters Parameters can be programmed without power supply (external battery) and parameters are stored in nonvolatile memory. Alarm conditions Low/high temperature and thermistor failure (open or shorted) Ground-fault trip, ground-fault circuit failure and loss of power. CONNECTION TERMINALS Power supply input Heating cable output Ground Thermistor Alarm Remote display panel ECW-GF-DP REMOTE PANEL (FOR ECW-GF CONTROLLER ONLY) 1.760 in. (44.7 mm) Power Ground-Fault Reset Ground-Fault Test ECW-GF-DP Blinking = Communication error Blinking = Ground-fault trip or circuitry failure Blinking = Ground-fault test pass Blinking alternately red and amber = Other alarm; check ECW-GF 4.110 in. (104.4 mm) 3.806 in. (96.7 mm) 3.275 in. (83.2 mm) 3 / 5

GENERAL Approvals Nonhazardous locations Environment Ambient operating temperature Humidity Indoors, dry area 32 F to 122 F (0 C to 50 C) 90% noncondensing FEATURES LED Buttons Power Connection 3 LEDs 1 green, 1 red, 1 amber 2: Ground-fault reset, Ground-fault test Power provided from ECW-GF controller 12 Vdc @ 100 ma 8 position terminal block 8 conductor 22 AWG shielded cable Alpha - Cat No. 1298C or equivalent 328 ft (100 m) maximum ORDERING DETAILS Description Catalog number Part number Weight/lbs Wall mounted digital electronic controller with ground fault ECW-GF P000000925 4.0 Remote display panel for ECW-GF ECW-GF-DP P000000926 0.3 Pipe mounting kit with power connection and end seal FTC-PSK P000000927 0.2 4 / 5 EN-DigiTraceECWFamily-DS-H58338 01/13 THERMAL MANAGEMENT SOLUTIONS

WWW.THERMAL.PENTAIR.COM NORTH AMERICA Tel: +1.800.545.6258 Fax: +1.800.527.5703 Tel: +1.650.216.1526 Fax: +1.650.474.7711 EUROPE, MIDDLE EAST, AFRICA Tel: +32.16.213.511 Fax: +32.16.213.603 ASIA PACIFIC Tel: +86.21.2412.1688 Fax: +86.21.5426.2917 cn. LATIN AMERICA Tel: +55.11.2588.1400 Fax: +55.11.2588.1410 Pentair and DigiTrace are owned by Pentair or its global affiliates. All other trademarks are the property of their respective owners. Pentair reserves the right to change specifications without prior notice. 2012 2013 Pentair. 5 / 5