Operating Instructions Air Conditioner

Similar documents
Operating Instructions Air Conditioner

Operating Instructions Air Conditioner

Operating Instructions Air Conditioner Ceiling (T2 type) 4-Way Cassette (U1 type) Model No. INDOOR UNIT Ceiling (T2 type) S-60PT2R5A S-71PT2R5A S-100P

Operating Instructions

Operating Instructions

Operating Instructions Air Conditioner

Operating Instructions Air Conditioner

Operating Instructions Air Conditioner

Operating Instructions Air Conditioner

DAIKIN ROOM AIR CONDITIONER. Operation Manual. English. Deutsch. Français. Nederlands. Español. Italiano. Ελληνικά. Portugues. Русский.

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

DAIKIN ROOM AIR CONDITIONER. Operation Manual

DUCTED AIR CONDITIONER. Owner s Manual. KD Series KD24. Kaden Owner s Manual 1

Operating Instructions Air Conditioner

Operating Instructions Air Conditioner

INVERTER ONE-TWO/ONE-THREE/ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

MULTI-SPLIT SYSTEM AIR CONDITIONER / HEAT PUMP. YN-M Series. Inverter++ Models. Two, Three, Four, and Five Zones (Dual, Triple, Quad, and Quint Multi)

OWNER S MANUAL KPD-105 DTN11 KPD-140 DVN11 KPD-140 DTN11 KPD-160 DTN11 KPD-52 DVR11

Owner s Manual INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

OPERATION MANUAL. System Inverter Air Conditioners FXNQ20A2VEB FXNQ25A2VEB FXNQ32A2VEB FXNQ40A2VEB FXNQ50A2VEB FXNQ63A2VEB

KSD-35 DR11 KUE-35 DVN11

Owner s Manual INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

Owner s Manual Super-Slim Four-Way Cassette

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

Operation manual. Split system air conditioners FDXM25F3V1B FDXM35F3V1B FDXM50F3V1B FDXM60F3V1B. Operation manual Split system air conditioners

IU-PSINV-HW12R IU-PSINV-HW16R IU-PSINV-HW18R IU-PSINV-HW25R

XS1271 XS1872 INSTRUCTION MANUAL MODE D EMPLOI This air conditioner uses the new refrigerant R410A.

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

Inverter Split-type Room Air Conditioner

General safety precautions English

General safety precautions English

Indoor Unit (2 Series)

AUTO COOL DRY FAN SPEED AIR SWING OFF ON TIMER TIMER OFF/ON FAN SPEED MODE TEMP AIR SWING TIMER ON SET OFF CANCEL AC RC SET CHECK CLOCK RESET

Operating Instructions Air Conditioner

GDDEM10 DEHUMIDIFIER

Bosch Split-Type Ductless Air Conditioner / Heat Pump

Operating Instructions

Operating Instructions Air Conditioner

XHS1271 XHS1872. This air conditioner uses the new refrigerant R410A. COOL/DRY/HEAT Model

30-pint Dehumidifier User Guide

Operating Instructions Air Conditioner

NEXXOS INVERTER USER MANUAL

Indoor Unit (2 Series)

WINDOW TYPE COOLING MODEL AKT7F AKT9F REVERSE CYCLE MODEL AKT7U AKT9U FUJITSU GENERAL LIMITED

Owner s Manual CS

OPERATION MANUAL. System air conditioners FXAQ15AUV1B FXAQ20AUV1B FXAQ25AUV1B FXAQ32AUV1B FXAQ40AUV1B FXAQ50AUV1B FXAQ63AUV1B

Features. Simple One-touch Wireless Remote Control The remote control unit has several features to facilitate automatic operation.

R410A SPLIT SERIES FIXED SPEED

Operating Instructions Air Conditioner

Operating Instructions Air Conditioner

Using the Remote Control Unit

Owner s Manual SPLIT-TYPE ROOM AIR CONDITIONER

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

OWNER S MANUAL. AIR CONDITIONER (SPLIT TYPE) For general public use Indoor unit RAS-10, 13, 18, 24, 30BKS-HK

PORTABLE AIR CONDITIONER

NOTE: All the illustrations in this manual are for explanation purposes only. Your air conditioner may be slightly different.

Owner s Manual. Fairwind Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER CS

REG-183J REG-253J RADS-151J RADS-183J RADS-253J RAD-283J

Owner s Manual TABLE OF CONTENTS

Operation manual. Split system air conditioners FBA35A2VEB FBA50A2VEB FBA60A2VEB FBA71A2VEB FBA100A2VEB FBA125A2VEB FBA140A2VEB

53 KNL / 53 QNL OWNER S MANUAL

SPLIT TYPE. Instruction manual

Table of Contents SAFETY FIRST. Owner s Manual. Safety Precautions Unit Specifications and Features Manual Operation (Without Remote)...

OPERATION MANUAL. VRV Classic System air conditioner RXYCQ8A7Y1B RXYCQ10A7Y1B RXYCQ12A7Y1B RXYCQ14A7Y1B RXYCQ16A7Y1B RXYCQ18A7Y1B RXYCQ20A7Y1B

General safety precautions English

General safety precautions English

R410A SPLIT SERIES DC INVERTER QUICK COUPLING

KMHS1872 KMHS2472 INSTRUCTION MANUAL MODE D EMPLOI. COOL/DRY/HEAT Model. Save These Instructions! Conserver ce mode d emploi

General safety precautions English

Split Air Conditioner

SYSTEM Inverter Air Conditioners

CPG*CA CPG*CD CGC*CA CGC*CD CIM*CA CIM*CD CPP*CA CPP*CD

OPERATING MANUAL AIR CONDITIONER DUCT TYPE. ART Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

INSTALLATION INSTRUCTIONS

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

ROOM AIR CONDITIONER. Read This Manual. Before using your air conditioner, please read this manual carefully and keep it for future reference.

OPERATING MANUAL. AIR CONDITIONER Duct Type. Indoor Unit ARTG36LH ARTG45LH ARTG54LH ARTG60LH PART NO KEEP THIS MANUAL FOR FUTURE REFERENCE

Reverse Cycle Split System Air Conditioner

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

Installer manual AG-AA10. Air/air heat pump IHB GB AG-AA10-30 AG-AA10-40/50

AIR CONDITIONER (SPLIT TYPE)

PORTABLE AIR-CONDITIONER MODEL: EPAC-A4010D(WH) Owner s Manual Please read this manual carefully before operating your set.

USER MANUAL. Safety Precautions. Unit Specifications and Features. Operating Instructions. Installation Instructions.

IMPORTANT INSTRUCTIONS READ & SAVE

RAV-SP181BT-UL RAV-SP241BT-UL RAV-SP301BT-UL RAV-SP361BT-UL RAV-SP421BT-UL

Owner s Manual Window Air Conditioner

40KMC KMQ

GMSG OWNER S MANUAL SPLIT-SYSTEM ROOM AIR CONDITIONER CONTENTS

Local air conditioner

General safety precautions English

WINDOW TYPE ROOM AIR CONDITIONER OPERATION AND INSTALLATION MANUAL

OPERATION MANUAL. Split system air conditioners FCQG35FVEB FCQG50FVEB FCQG60FVEB FCQG71FVEB FCQG100FVEB FCQG125FVEB FCQG140FVEB

INSTALLATION AND USER MANUAL

R410A. AIR CONDITIONER DUCT TYPE / ART Series OPERATING MANUAL. REFRIGERANT This Air Conditioner contains and operates with refrigerant R410A.

SPLIT - TYPE ROOM AIR CONDITIONER

OPERATING MANUAL AIR CONDITIONER CASSETTE TYPE. AUT Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

Dehumidifier. Instruction Manual

1. Safety Precautions Operation Care and cleaning Troubleshooting Specifications... 8

INVERTER SPLIT-TYPE ROOM AIR CONDITIONER

Transcription:

Operating Instructions Air Conditioner Low Silhouette Ducted (Type F1) INDOOR UNIT Low Silhouette Ducted (Type F1) S-60PF1R5A S-71PF1R5A S-100PF1R5A S-125PF1R5A S-140PF1R5A OUTDOOR UNIT Single Split (Single-phase) U-60PE1R5A U-71PE1R5A U-100PE1R5A U-125PE1R5A U-140PE1R5A Single Split (3-phase) U-100PE1R8A U-125PE1R8A U-140PE1R8A Before operating the unit, read these operating instructions thoroughly and keep them for future reference. Panasonic Corporation 1006 Kadoma, Kadoma City, Osaka, Japan F569974

2 Thank you for purchasing this Panasonic product. This product is a commercial air conditioner indoor unit. Installation Instructions attached. Contents zsafety Precautions... 2 zprecautions for Use... 4 znames of Parts... 5 Operation Mechanism... 5 zmaintenance... 6 Before Requesting Services... 6 ztroubleshooting... 7 zspecifications... 8 Indoor unit... 8 Outdoor unit... 9 Product Information If you have problems or questions concerning your Air Conditioner, you will need the following information. Model and serial numbers are on the nameplate on the side of the unit. Serial No. Date of purchase Dealer s address Phone number Safety Precautions The following symbols used in this manual, alert you to potentially dangerous conditions to users, service personnel or the appliance: WARNING CAUTION Prohibited matters This symbol refers to a hazard or unsafe practice which can result in severe personal injury or death. This symbol refers to a hazard or unsafe practice which can result in personal injury or product or property damage. Matters to be observed Read these Operating Instructions carefully before using this air conditioner. If you still have any difficulties or problems, consult your dealer for help. This air conditioner is designed to give you comfortable room conditions. Use this only for its intended purpose as described in these Operating Instructions. WARNING Confirm to authorized dealer or specialist on usage of specified refrigerant type. Using of refrigerant other than the specified type may cause product damage, burst and injury etc. This air conditioner has no ventilator for intaking fresh air from outdoors. You must open doors or windows frequently when you use gas or oil heating appliances in the same room, which consume a lot of oxygen from the air. Otherwise there is a risk of suffocation in an extreme case. Never use or store gasoline or other flammable vapor or liquid near the air conditioner it is very dangerous. Do not use this appliance in a potentially explosive atmosphere. Never touch the unit with wet hands. Do not insert your fingers or other objects into the air conditioner indoor or outdoor unit, rotating parts may cause injury. If the refrigerant comes in contact with a flame, it produces a toxic gas. For safety, be sure to turn the air conditioner off and also to disconnect the power before cleaning or servicing. Pull off the power plug from a receptacle, or switch off the breaker, or switch off the power disconnecting mean to isolate the air conditioner from the main power supply in case of emergency. Do not clean inside the indoor and outdoor units by users. Engage authorized dealer or specialist for cleaning. In case of malfunction of this appliance, do not repair by yourself. Contact to the sales dealer or service dealer for a repair.

Provide a power outlet to be used exclusively for each unit, and a power supply disconnect, Earth Leakage Circuit Breaker (ELCB) or Residual Current Device (RCD) for overcurrent protection should be provided in the exclusive line. Provide a power outlet exclusively for each unit, and full disconnection means having a contact separation in all poles must be incorporated in the fixed wiring in accordance with the wiring rules. To prevent possible hazards from insulation failure, the unit must be grounded. Do not use modified cord, joint cord, extension cord or unspecified cord to prevent overheating and fire. Stop using the product when any abnormality/failure occurs and disconnect the power plug or turn off the power switch and breaker. (Risk of smoke/fire/electric shock) Examples of abnormality/failure The ELCB trips frequently. The product sometimes does not start when turned on. The power is sometimes disconnected when the cord is moved. Burnt odor or abnormal noise is detected during operation. The body is deformed or abnormally hot. Water leaks from the indoor unit. Power cord or plug becomes abnormally hot. Fan speed cannot be controlled. The unit stops running immediately even if it is switched on for operation. The fan does not stop even if the operation is stopped. Contact immediately your local dealer for maintenance/repair. Do not sit or step on the unit. You may fall down accidentally. NOTICE CAUTION This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for commercial use by lay persons. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that do not play with the appliance. Keep the fire alarm and the air outlet at least 1.5m away from the unit. Do not cool or heat the room too much if babies or invalids are present. Do not turn the air conditioner on and off from the power mains switch. Use the ON/OFF operation button. Do not stick anything into the air outlet of the outdoor unit. This is dangerous because the fan is rotating at high speed. Do not touch the air inlet or the sharp aluminum fins of the outdoor unit. You may get injured. Do not stick any object into the FAN CASE. You may be injured and the unit may be damaged. The compressor may occasionally stop during thunderstorms. This is not a mechanical failure. The unit automatically recovers after a few minutes. Important Information Regarding The Refrigerant Used This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. Do not vent gases into the atmosphere. Refrigerant type: R410A GWP (1) value: 1975 (1) GWP = global warming potential Periodical inspections for refrigerant leaks may be required depending on European or local legislation. Please contact your local dealer for more information. 3

Precautions for Use Installation zthis air conditioner must be installed properly by qualified installation technicians in accordance with the Installation Instructions provided with the unit. zbefore installation, check that the voltage of the electric supply in your home or office is the same as the voltage shown on the nameplate. WARNING Avoid the following locations for installation. zlocations where smoke or combustible gas exists. Also locations of extremely high temperature such as a greenhouse. zlocations where excessively high heat-generating objects are placed. Attention: zavoid installing the outdoor unit where salty sea water can splash directly onto it or in sulphurous air near a spa. (To protect the air conditioner from heavy corrosion) Wiring zall wiring must conform to the local electrical codes. (Consult your dealer or a qualified electrician for details.) zeach unit must be properly grounded with a ground (or earth) wire or through the supply wiring. zwiring must be done by a qualified electrician. Operation Preparation Operation Condition Use this air conditioner under the following temperature range. Indoor temperature range: Cooling mode 14 C ~ 25 C (*WBT) / 18 C ~ 32 C (*DBT) Heating mode 16 C ~ 30 C (*DBT) Outdoor temperature range: Cooling mode -15 C ~ 46 C (*DBT) Heating mode -20 C ~ 18 C (*WBT) / -20 C ~ 24 C (*DBT) *DBT: Dry bulb temperature *WBT: Wet bulb temperature Information for Users on Collection and Disposal of Old Equipment and Used Batteries Pb [Information on Disposal in other Countries outside the European Union] These symbols are only valid in the European Union. If you wish to discard these items, please contact your local authorities or dealer and ask for the correct method of disposal. Note for the battery symbol (bottom two symbol examples): This symbol might be used in combination with a chemical symbol. In this case it complies with the requirement set by the Directive for the chemical involved. Turn the power mains on 5 hours before the start of operation. (For warm-up) zleave the power mains ON for continuous use. ON NOTE Pull off the power plug from a receptacle, or switch off the breaker, or switch off the power disconnecting mean to isolate the air conditioner from the main power supply when not in use for a long time. 4 Tips for Energy Saving Avoid zdo not block the air intake and outlet of the unit. (If either is obstructed, the unit will not function well, causing malfunction.) zduring cooling operation, use sunshades, blinds or curtains to prevent direct sunlight from entering the room. Do zalways keep the air filter clean. (A clogged filter will impair the performance of the unit.) Maintenance (P.6) zto prevent conditioned air from escaping, keep windows, doors and any other openings closed.

Names of Parts INDOOR UNIT OUTDOOR UNIT Air outlet duct * Bolt anchor * Suspension bolt * Air intake Air intake Indoor unit Ceiling material * Air-outlet grille * * Field supplied Type F1 (Low Silhouette Ducted) Air outlet Air outlet Type 60, 71 Type 100, 125, 140 Optional Wireless Remote Controller CZ-RWSK2 CZ-RWSC3 Timer Remote Controller CZ-RTC2 CZ-RTC4 High-spec Wired Remote Controller CZ-RTC3 Read the operating instructions included with the Remote Controller. Operation Mechanism Heating performance zsince this air conditioner utilizes outside air for heating, its heating performance deteriorates as outside temperature decreases. (Due to heat pump system) In that case, use another heating appliance. Defrosting zthis appliance may start defrosting operation to melt frost formed in the outdoor unit. Defrosting starts: The indoor unit fan stops (or the speed becomes extremely slow). (STANDBY) appears. Heating operation resumes after several minutes: The indoor unit fan remains stopped (or it will run at a very slow speed) until the indoor heat exchanger coil warms up sufficiently. (STANDBY) is shown. Defrosting is complete: The indoor unit fan starts operation. (STANDBY) disappears. DRY operation zonce the room temperature reaches the level that was set, the outdoor unit repeats the cycle of turning on and off automatically. zwhen the outdoor unit is turned off, the indoor unit fan will stop, too. (To prevent the humidity in the room from rising again) zwhen the room temperature is more likely to reach the level that was set, the fan speed is set to breeze (light wind) automatically. z DRY operation is not possible if the outdoor temperature is 15 C or less. Should the power failure occurs while the unit is running When the unit automatically resumes operation after temporary power failure, it uses the same settings before the power was cut off. 5

Maintenance Do not attempt to clean inside the unit by yourself. Refer to the section Care and Cleaning in the Installation Instructions. WARNING zfor safety, be sure to turn the air conditioner off and disconnect the power before cleaning. (Otherwise, electric shock or injury may result because the fan is rotating at high speed.) zdo not pour water on the indoor unit. (This may damage the internal components and cause an electric shock hazard.) CAUTION znever use solvents or harsh chemicals. Also, do not wipe plastic parts using very hot water. (This may cause deformation or change in colour.) zsome metal edges and fins are sharp. Be careful when you clean those parts. (Injury may result.) zuse a firm stool or ladder when cleaning an indoor unit installed in high locations. Before Requesting Services Symptom Cause Action The air conditioner does not operate although the power is turned on. Power failure or after power failure The operation (power) button is turned off. Fuse blow out. Press the power ON/OFF button on the remote controller. If the breaker is turned off, turn the power on. If the breaker has been tripped, consult your dealer without turning it on. Contact your dealer. Poor cooling or heating performance The air intake or air outlet of indoor and outdoor units is clogged with dust. Improper temperature settings The room is exposed to direct sunlight in cooling mode. Doors or windows are open. The air filter is clogged. Too many heat sources in the room in cooling mode. Too many people in the room in cooling mode. Remove the dust. See Tips for Energy Saving. (P.4) Contact your dealer. Use minimum heat sources and in a short time. Lower the temperature setting. If your air conditioner does not work properly even after checking each item of Before Requesting Services and Troubleshooting zstop the operation immediately and turn the power off. Then contact your dealer and report the serial number and symptom. You also report if the inspection mark and the letters E, F, H, L, P in combination with numbers appear on the LCD of the remote controller. znever repair the air conditioner by yourself since it is very dangerous for you to do so. 6

Troubleshooting Check before consulting or requesting services. Symptom Cause / Action Noise Sound like streaming water is heard during operation or after operation. Cracking noise is heard during operation or when operation stops. Sound of refrigerant liquid flowing inside unit Sound of drainage water through drain pipe Sound due to temperature changes of parts Discharged air smells during operation. Indoor odor components, cigarette odor and cosmetic odor accumulated in the air conditioner and its air is discharged. The unit inside is dirty. (Contact your dealer.) Indoor unit Dewdrops accumulate near the air outlet during cooling operation. Fog occurs during cooling operation. Fog occurs during heating operation. Internal moisture is cooled by cool wind and accumulates as dewdrops. If the air conditioner has been installed at places such as restaurants where large amounts of oil mist exist, cleaning is necessary because the unit inside (heat exchanger) is dirty. (Contact your dealer.) Defrost operation is in process. The fan is rotating for a while even though operation stops. Fan rotation makes operation smooth. The fan may rotate to dry the heat exchanger depending on the setting. Dust is discharged. Dust accumulated inside the indoor unit is discharged. At the initial high-speed operation, the fan sometimes rotates faster than the setting speed. (3 to 30 minutes) This is for operation check in order to confirm whether the fan motor rotation is within the range of use. Outdoor unit No operation (When the power is turned on immediately / When operation is stopped and resumed immediately) Noise occurs during heating operation. Steam comes out during heating operation. The fan continues to rotate even after the operation is stopped using the remote controller. Operation is not activated for the first approx. 3 minutes because the compressor protection circuit is activated. Defrost operation is in process. This is for smooth operation. 7

Specifications Indoor unit Low Silhouette Ducted (Type F1) Model Name S-60PF1R5A S-71PF1R5A S-100PF1R5A S-125PF1R5A S-140PF1R5A Power source Cooling capacity Heating capacity 230/240 V~ 50 Hz kw 6.0 7.1 10.0 12.5 14.0 BTU/h 20,500 24,200 34,100 42,700 47,800 kw 7.0 8.0 11.2 14.0 16.0 BTU/h 23,900 27,300 38,200 47,800 54,600 High db(a) 35 35 38 39 40 Sound pressure level Medium db(a) 32 32 34 35 36 Low db(a) 26 26 31 32 33 High db(a) 58 58 61 62 63 Sound power level Medium db(a) 55 55 57 58 59 Low db(a) 49 49 54 55 56 Unit dimensions (H W D) mm 290 1,000 700 290 1,000 700 290 1,400 700 290 1,400 700 290 1,400 700 Net weight kg 33 33 45 45 45 8

Outdoor unit Single Split Outdoor Unit Model Name U-60PE1R5A U-71PE1R5A U-100PE1R5A U-125PE1R5A U-140PE1R5A Power source Cooling capacity Heating capacity 230/240 V~ 50 Hz kw 6.0 7.1 10.0 12.5 14.0 BTU/h 20,500 24,200 34,100 42,700 47,800 kw 7.0 8.0 11.2 14.0 16.0 BTU/h 23,900 27,300 38,200 47,800 54,600 Sound pressure level (C/H) db(a) 48 / 50 48 / 50 52 / 52 53 / 53 54 / 55 Sound power level (C/H) db(a) 65 / 67 65 / 67 69 / 69 70 / 70 71 / 71 Unit dimensions (H W D) mm 996 940 340 996 940 340 1,416 940 340 1,416 940 340 1,416 940 340 Net weight kg 68 69 98 98 98 Model Name U-100PE1R8A U-125PE1R8A U-140PE1R8A Power source Cooling capacity Heating capacity 400/415 V 3N~ 50 Hz kw 10.0 12.5 14.0 BTU/h 34,100 42,700 47,800 kw 11.2 14.0 16.0 BTU/h 38,200 47,800 54,600 Sound pressure level (C/H) db(a) 52 / 52 53 / 53 54 / 55 Sound power level (C/H) db(a) 69 / 69 70 / 70 71 / 71 Unit dimensions (H W D) mm 1,416 940 340 1,416 940 340 1,416 940 340 Net weight kg 98 98 98 9

10 MEMO

MEMO 11

Panasonic Corporation Website: http://www.panasonic.com Panasonic Corporation 2015 Printed in China F569974 DC0115-0