NOVALYNX CORPORATION MODEL 200-WS-21-A DUAL SET POINT WIND ALARM INSTRUCTION MANUAL

Similar documents
NOVALYNX CORPORATION MODEL A & A SLING PSYCHROMETER INSTRUCTION MANUAL

NOVALYNX CORPORATION MODEL A EVAPORATION PAN AUTOMATIC REFILL SYSTEM INSTRUCTION MANUAL

NOVALYNX CORPORATION

NovaStar 4X Pager Alarm Software 5073NS4X-AD DCN-M409

Installation and Operations Manual

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Global Water Instrumentation, Inc.

AirGard 385 Fume Hood Monitor

Global Water Instrumentation, Inc.

Mark 25 Ultrapure Water Conductivity Analyzer

HIn3550 Magnetic Field Monitor User's Manual

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

Model 4001 Series Single Channel Controller

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

ENGINE MONITOR VOTT MODEL: YEAR WARRANTY

CPS-1 USER S MANUAL AIR INLET / CURTAIN CONTROL

CO2 RESPONDER Portable Carbon Dioxide Detector QUICK REFERENCE GUIDE

PRESSURA ROOM PRESSURE MONITOR MODELS 8630-SM 8630-PM

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

METEOROLOGICAL INSTRUMENTS

User's Guide. Pinless Moisture Meter. Model MO257

PRESSURA ROOM PRESSURE CONTROLLER MODELS 8630-SC 8630-PC

Digital Refrigerator/Freezer Thermometer model 00986

Dual Laser InfraRed (IR) Thermometer

Alarm Tone Generator Model AG17

SCAN200E USER S MANUAL

6502B RF Distribution

CA5000 Liquid CO 2 Freezer Backup System

METEOROLOGICAL INSTRUMENTS

ANEMOMETER 4403-RF-BAT

RAM3 Remote Alarm Module

VS2000V Veterinary Vital Signs Monitor Operation Manual

Instruction Manual PCS-400-XY. Pump Controller. Y=2: 4-20 ma Y=6: 0-10 VDC X=5: 1-5 VDC. 4 Pump Control Relays 1 Alarm Relay 1 Signal Fail

Automatic Air-Operated Large Format Press

External Wireless Sounder

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

CSP-204 CSP-208 CSP-104 CSP-108

HIGH VOLTAGE A.C. PROXIMITY DETECTOR HI-PROX

OPERATING MANUAL TORREY PINES SCIENTIFIC, INC. DIGITAL HPLC COLUMN HEATER MODEL CO20 DOCUMENT NUMBER CO20-00

High Temperature InfraRed Thermometer with Laser Pointer

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

Beacon 800 Gas Monitor Operator s Manual

FLOW CONTROLLER TYPE S/601

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

The Information Contained in this Document is Proprietary and should only be used for Service or Training of Authorized Blodgett Servicers who will

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

VX SERIES Wireless Thermostat with Occupancy Sensor

ProStar 325 UV-Vis Detector

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Hades 2. Digital Recycle and Lighting Timer with High Temp Shut-Off Instruction Manual. Notes: 1 Square = Foot/Feet

1228s Multidrop INSTRUCTIONS. Installation and Operation of the AMC-1228s Electrochemical Sensor Module For Use With Multidrop AMC Monitors

ENMET Corporation. PO Box 979 Ann Arbor, MI RECON. Manual. Manual Part Number MCN-410, 12/03/08

GAS MONITOR Model Model

Advantium 16 System Monitor

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

! "! # Please read these installation and operating instructions completely and carefully before starting.

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

NexSysLink. 2 CAN Display Operation Manual. CAN Instruments Product Family

Ambient Weather WS-091-C Three Channel Display Wireless Thermometer (Console Only) User Manual

3800 North Mill Road Vineland, NJ USA Tel: Fax: Web: Rev. A

GROUP OF COMPANIES. MERLIN STEALTH Electric Fence Energizer. Users Manual

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

NT DUAL CHANNEL DISPLAY. User Guide

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

APPLICATION NOTE. Applying pressure sensing in arc flash protection applications with air magnetic circuit breakers

TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm

Technical Manual. LeakFilm 5. 5 Channel Conductive Liquid Leak Detection Controller

GasScanner 1C. Single Channel Monitor. Operator s Manual. MINT-0278-XX Rev A

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08

Maintenance Manual PC6010. WARNING This manual contains information on limitations regarding product use and function

Preamplifier Power Supply PPS-02 user's guide

MODEL ZAC ZONE ANNUNCIATOR/CONTROLLER DESIGNED FOR ZONE ANNUNCIATION AND MONITORING

Warranty Registration

Reacti-Therm I and III Heating/Stirring Modules

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. H 2015 Pentair Equipment Protection P/N

EasyTronic III MANUAL SERVICE

MST-1. Varifan USER S MANUAL MST-1 ADJUST. 9 per day HI F2. DIFF on off TIMER. reduc.

ANALOX 101 D2 PORTABLE OXYGEN MONITOR USER MANUAL

Custom Control Systems Inc. Ellis Dryer Control Configuration and Operation Manual

ENMET 680 Fairfield Court Ann Arbor, MI Fax LC-8 Controller Operation and Maintenance Manual

Henny Penny Island Warmer Model HMI-103 Model HMI-105 TECHNICAL MANUAL

Instruction Manual. AcuRite Atlas. Indoor Display model 06061

PHASE COIN USER S MANUAL

Notes: 1 Square = 1 Foot

INSTRUCTION MANUAL P Heating and 1 Cooling

Tachometer/Hourmeter/Trip. Installation and Operation Manual

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

High Temperature Remote Gas Calibrator

Controllers. Instruction Manual WARNING

CIRRUS PRO. User Manual and Responsibilities ASPIRATING FIRE DETECTOR

Sirius Control Box 6130 LRIT

Sirius Technologies, Inc.

Miniature Thermoelectric Cooler Controller MTCC-01 user's guide

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

Remote Relay Module (RRM)

Transcription:

NOVALYNX CORPORATION MODEL 200-WS-21-A DUAL SET POINT WIND ALARM INSTRUCTION MANUAL REVISION DATE: JAN 2005

Receiving and Unpacking Carefully unpack all components and compare to the packing list. Notify NovaLynx Corporation immediately concerning any discrepancy. Inspect equipment to detect any damage that may have occurred during shipment. In the event of damage, any claim for loss must be filed immediately with the carrier by the consignee. Damages to equipment sent via Parcel Post or UPS require the consignee to contact NovaLynx Corporation for instructions. Returns If equipment is to be returned to the factory for any reason, call NovaLynx between 8:00 a.m. and 4:00 p.m. Pacific Time to request a Return Authorization Number (RA#). Include with the returned equipment a description of the problem and the name, address, and daytime phone number of the sender. Carefully pack the equipment to prevent damage or additional damage during the return shipment. Call NovaLynx for packing instructions in the case of delicate or sensitive items. If packing facilities are not available take the equipment to the nearest Post Office, UPS, or other freight service and obtain assistance with the packaging. Please write the RA# on the outside of the box. Warranty NovaLynx Corporation warrants that its products are free from defects in material and workmanship under normal use and service for a period of one year from the date of shipment from the factory. NovaLynx Corporation's obligations under this warranty are limited to, at NovaLynx's option: (i) replacing; or (ii) repairing; any product determined to be defective. In no case shall NovaLynx Corporation's liability exceed product's original purchase price. This warranty does not apply to any equipment that has been repaired or altered, except by NovaLynx Corporation, or that has been subjected to misuse, negligence, or accident. It is expressly agreed that this warranty will be in lieu of all warranties of fitness and in lieu of the warranty of merchantability. Address NovaLynx Corporation 4055 Grass Valley Highway, Suite 102 Auburn, CA 95602 Phone: (530) 823-7185 Fax: (530) 823-8997 Email: nova@novalynx.com Website: www.novalynx.com Copyright 2005 by NovaLynx Corporation i

TABLE OF CONTENTS Section No. Page No. 1.0 INTRODUCTION.................................................. 1 2.0 GENERAL DESCRIPTION........................................... 1 2.1 ANEMOMETER.............................................. 1 2.2 CONTROL MODULE.......................................... 1 3.0 OPERATION..................................................... 2 3.1 USER INTERFACE........................................... 2 3.2 MENU STRUCTURE.......................................... 2 3.3 ALARM FEATURES.......................................... 3 3.4 UNITS OF MEASURE......................................... 3 3.5 ANEMOMETER PLACEMENT.................................. 3 3.6 WIND INPUTS............................................... 3 3.7 POWER SUPPLY............................................ 4 3.8 EARTH GROUND............................................ 4 4.0 QUICK START.................................................... 4 5.0 SPECIFICATIONS................................................. 6 ii

MODEL 200-WS-21-A EQUIPMENT CONFIGURATION AND IDENTIFICATION 200-WS-21-A Menus iii

1.0 INTRODUCTION NovaLynx Corporation Model 200-WS-21-A Dual Set Point Wind Alarm Instruction Manual The NovaLynx 200-WS-21-A is a microprocessor-based dual set point wind speed alarm packaged in a NEMA4X box with a transparent cover. It has been designed with two independently controlled relays. The relays are used to control power to the users wind speed sensitive device(s). The control module has a liquid crystal digital display and push buttons for viewing and selection of the operating mode and the alarm threshold values. The user can control three parameters for each alarm channel: threshold wind speed delay before the relay triggers, after threshold speed is exceeded, and delay time before the relay turns off after the wind speed drops below the threshold. Each relay can be used in either the normally open or the normally closed mode. A piezoelectric buzzer in the control module can be activated to turn on when ever the alarm state is active. 2.0 GENERAL DESCRIPTION The NovaLynx 200-WS-21A consists of two components, an anemometer to measure wind speed and a control module. 2.1 ANEMOMETER The Model 200-WS-01B anemometer uses three rotating cups to sense wind velocity. As the wind blows past the cups, the pressure of the wind against the insides of the cups causes the cups to rotate. There are three permanent magnets embedded in the hub that holds the cups. As the hub rotates on its instrument grade ball bearing, each magnet passes over a fixed magnetic reed switch mounted in the anemometer base. The magnetic reed switch is normally open and the contacts close each time a magnet passes over the switch. The ratio of closed to open time for the magnetic reed switch is nominally 1 to 9. Thus three switch closures are generated per revolution of the anemometer cups. The anemometer is rated for wind speeds up to 125 mph and has a starting threshold of approximately 1 mph. 2.2 CONTROL MODULE The function of the Control Module is to activate control relays when ever user selected wind speeds are reached and sustained for user determined periods of time. The Control Module is microprocessor based and is controlled via push buttons and a two-row-liquid-crystal-display. There are Option Switches on the printed circuit board for 1

selection of wind speed units (mph or kph), for enabling the audible alarm, and for controlling the LCD contrast. 3.0 OPERATION 3.1 USER INTERFACE There are two modes of operation for the NovaLynx model 200-WS-21A Wind Speed Alarm, RUNNING and PAUSED. The RUNNING mode is the normal operating mode when the unit is initially powered up. The PAUSED mode is any state other than the normal OPERATING mode. Pressing any button during the RUNNING mode will place the unit in the PAUSED mode. 3.2 MENU STRUCTURE The user interface contains the following menu items: C Wind Alarms C Alarm Delays C Max Wind Speed The MENU Button The MENU button will take the unit out of the RUNNING mode and allow the user to change the operating parameters and view maximum values. Once the MENU button has been pressed the user may use the UP and DOWN buttons to scroll through the menu. Subsequent presses of the MENU button will bounce the cursor between editable fields of any menu item, where applicable. When in an editable field, the cursor will become a blinking block. The GO Button The GO Button always returns the unit to the RUNNING mode, regardless of where the user may be in the menu structure. The UP and DOWN Buttons The UP and DOWN buttons control either of two things: 1. Scrolling through menu items when the user is not in an editable field. 2. Scrolling through user selectable values when the user is in an editable field. 2

The CLEAR Button Pressing the CLEAR button performs the following actions: 1. If the user is in an editable field, the field will be set to the lowest possible value. 2. It the user is viewing the maximum the wind value, the recorded value will be cleared. 3. If the unit is alarming, all delay counters will be cleared. 3.3 ALARM FEATURES The NovaLynx 200-WS-21-A Wind Speed Alarm provides the following alarm features: C Two independent wind speed alarms C Programmable On and OFF delays C Pausing of alarm when any key is pressed C Audible and Silent modes When audible, Alarm 1 will produce a beep at 400 ms intervals while Alarm 2 will beep at 200 ms intervals. When the alarms are in the audible mode and both alarms are active, Alarm 2 will have precedence. The alarm can be put into the silent mode by moving Switch 4 to the off position on the switch block at the bottom of the circuit board. It is necessary to re-boot the 200-WS-21A after moving the switch in order to enable the change. 3.4 UNITS OF MEASURE It is possible to display wind speed values in either American standard units or in metric units. Selection of the unit system to be used is done with Switch 2 on the switch block at the bottom of the circuit board. The Off position is for mph and the On position is for km/hr. It is necessary to re-boot the 200-WS-21A after moving the switch in order to in able the change. 3.5 ANEMOMETER PLACEMENT The validity of anemometer signals can be compromised by the choice of the location of the anemometer with respect to the surrounding terrain. Placement of the anemometer should follow standards established by agencies such as the World Meteorological Organization (WMO) and the National Oceanic and Atmospheric Administration's (NOAA) National Weather Service (NWS) 3.6 WIND INPUTS The wind speed inputs on the printed circuit board are labeled WND+ and WNDg. 3

3.7 POWER SUPPLY Use a 12V ac or dc power supply on the AC in/dc in and AC in/dc gnd terminals. Connect the two wires of the 200-WS-01B to these terminals and connect the cable shield to an earth ground. 3.8 EARTH GROUND Attach a wire of at least 18 AWG or larger to the EARTH terminal. The other end of this wire must be attached to a metal water pipe or a copper ground rod. This is the ground path for all of the lightning and electrostatic protection devices incorporated on the 200-WS-21-A circuit board. 4.0 QUICK START Before permanently installing the WS-21-A it is advisable to "bench test" it to gain familiarity with its operation. The test is conducted in the following manner. Attach the anemometer (200-WS-01B) leads to the terminals on the 200-WS-21-A circuit board labeled WND+ and WND g. These terminals are on the right hand side of the circuit board. Attach 12V dc or ac to the terminals on the 200-WS-21-A circuit board marked AC in/dc in and AC in/dc gnd. These terminals are on the lower left hand side of the circuit board. 4

When the 200-WS-21-A circuit board is energized the LCD is activated and it will display the wind speed on the first line and the alarm set point values on the second line. Spin the anemometer cups by hand and you will see the wind speed displayed on the top line of the display. There are five control buttons next to the LCD. These are used to set the alarm thresholds for the two alarms, to set the delay times between the time that the wind speed crosses the alarm threshold and when the alarm state changes conditions, and to clear the maximum wind speed value in the maximum wind speed log. The default condition for the wind speed alarms is 15 mph. Both the on-delay and the off-delay default values are 15 seconds. To change the wind speed alarm threshold value press the Menu button. The top line of the display will change from "WIND X.X (mph)" to "Wind Alarms (mph)". Press the Menu button again and the cursor moves over the Alarm 1 speed value. Press the Up or Dn button to increment or decrement the alarm threshold value for Alarm 1. Press the Go button to return to the RUNNING mode. To Change the Alarm On and Alarm Off delays, with the unit in the RUNNING mode press the Menu button and the "Wind Alarms (mph)" menu will appear. Then press the Up button ant the "Alarm Delays (s)" menu will appear. Press the Menu button and the cursor will move to the "ON: XX" field. Then Press the Up or Dn button to increment or decrement the On delay value to the desired value. Press the Menu button again to advance the cursor to the "OFF: XX" field and adjust the value with the Up or Dn button. Press the Go button to return to the RUNNING mode. To view the Maximum Wind Speed register from the RUNNING mode press the Menu button, then press the Up button. The "Max Wind Speed" screen will be displayed and the second line will show the maximum wind speed obtained since the last reset. To reset the maximum wind speed value to zero press the Clr button. Press the Go button to return to the RUNNING mode. This concludes the series of quick start tests. 5

5.0 SPECIFICATIONS Sensor Wind Speed Transducer Wind Speed Resolution Survivability Speed Wind Speed Resolution Wind Speed Threshold Wind Speed Integration Interval Wind Speed Accuracy Alarm Delay Range ON or Off Controls Option Slide Switch Three cup anemometer Sealed magnetic switch 0 to 99 mph 125 mph 0.1 mph 1 mph 2 seconds 0.5 mph or 3% (which ever is greatest) 0-99 seconds Four, push buttons select: 1. Run or Pause mode 2. Menu Select 3. Increment 4. Decrement (Switches are read only during power-up.) Switch 1: OFF = WIND Switch 2: OFF = mph, ON = km/hr Switch 3: N/A Switch 4: ON = Silent alarms, OFF = Audible alarms 6