Machine Tool Coolant Units Drill presses, tool grinders, tapping machines, cut-off saws, bench mills, lathes /5 HP fan-cooled motor Vertical machine coolant VMC- Capacity: GPH @ ' 9 LPH @. m Liquid Temperature: F (9 C) Electrical: 5v, Hz, A Item # Model Volts Cord Protection 5 VMC- 5 '. m Little Giant Machine Tool Coolant Units are designed for virtually any machine tool operational need. Units are engineered so that coolant flow can be regulated to desired amount, or completely shut off without harmful effects to the motor. MTC units use only centrifugal-type pumps. It is recommended that all machine tool pumps have Viton shaft seals, if shaft seal is required.
Machine Tool Coolant Tanks Drill presses, tool grinders, tapping machines, cut-off saws, bench mills, lathes 5-gallon (.9 liter) polyethylene tank Metal chip collector basket and baffle ' (. m) plastic hose, plastic flex nozzle and brass control valve, plus all adapters and fittings for use with recommended pumps (see chart below) Pump not included* MCT-5P Series Specifications Item # Model 5 MCT-5P Recommended Pumps for MCT-5P (GPH at 5v, Hz) Item # Model For MCT Unit 7 5 -YS MCT-5P 7 LPH 5 NK- MCT-5P 57 NK- MCT-5P 5 E-N MCT-5P 5 E-N MCT-5P 55 5-MSP MCT- 57 -CIM-R MCT- GPH Water Soluble Oil GPH SSU/Cutting Oil GPH SSU/Cutting Oil ' ' ' ' Shut off ' ' ' ' Shut off ' ' ' ' Shut off 7 5 LPH LPH 7 LPH 57 LPH LPH 5 7 LPH 7 LPH 7 LPH 7 95 LPH LPH 9 LPH 77 LPH 7 7 LPH LPH 5 LPH LPH LPH 9 5 LPH 9 75 LPH 7 LPH LPH 9 7 LPH 79 LPH 7 LPH 7 LPH 7.'. m.'. m.'.7 m.'.9 m.' 7. m.'. m.5' 5. m 9 LPH 9 LPH 5 LPH 9 7 LPH 95 LPH 9 LPH 5 LPH *NOTE: The MCT-5P unit does not include pump. Pump must be purchased in addition to unit. 5 LPH 5 LPH 9 9 LPH LPH 9 7 LPH 59 LPH 55 LPH 9 7 LPH 79 99 LPH 7 LPH 5 5 LPH 7 LPH 5 LPH 57 LPH 9 LPH 9 LPH.5'. m 5.'.5 m.'.9 m.' 5. m.' 5. m.'.5 m.7'.5 m 7 5 LPH 75 LPH 7 LPH 9 LPH 5 LPH 7 9 LPH 5 7 LPH 7 5 LPH 7 LPH LPH LPH LPH 7 7 LPH 5 LPH LPH 7 7 LPH 5.7'. m 7.5' 5. m.5'. m.'. m
Machine Tool Coolant Tanks Drill presses, tool grinders, tapping machines, cut-off saws, bench mills, lathes -gallon (7. liter) metal tank with baffle ' (. cm) neoprene hose with brass fittings, plastic flex nozzle and brass control valve Removable chip collector tray and splash deflector, plus all adapters and fittings for use with recommended pumps (see chart below) Pump not included* MCT- Series Specifications Item # Model 5 MCT- Recommended Pumps for MCT- (GPH at 5v, Hz) Item # Model For MCT Unit 5 -YS MCT-5P 5 NK- MCT-5P 57 NK- MCT-5P 5 E-N MCT-5P 5 E-N MCT-5P 55 5-MSP MCT- 57 -CIM-R MCT- GPH Water Soluble Oil GPH SSU/Cutting Oil GPH SSU/Cutting Oil ' ' ' ' Shut off ' ' ' ' Shut off ' ' ' ' Shut off 7 7 LPH 7 5 LPH LPH 7 LPH 57 LPH LPH 5 7 LPH 7 LPH 7 LPH 7 95 LPH LPH 9 LPH 77 LPH 7 7 LPH LPH 5 LPH LPH LPH 9 5 LPH 9 75 LPH 7 LPH LPH 9 7 LPH 79 LPH 7 LPH 7 LPH 7.'. m.'. m.'.7 m.'.9 m.' 7. m.'. m.5' 5. m 9 LPH 9 LPH 5 LPH 9 7 LPH 95 LPH 9 LPH 5 LPH * NOTE: The MCT- unit does not include pump. Pump must be purchased in addition to unit. 5 LPH 5 LPH 9 9 LPH LPH 9 7 LPH 59 LPH 55 LPH 9 7 LPH 79 99 LPH 7 LPH 5 5 LPH 7 LPH 5 LPH 57 LPH 9 LPH 9 LPH.5'. m 5.'.5 m.'.9 m.' 5. m.' 5. m.'.5 m.7'.5 m 7 5 LPH 75 LPH 7 LPH 9 LPH 5 LPH 7 9 LPH 5 7 LPH 7 5 LPH 7 LPH LPH LPH LPH 7 7 LPH 5 LPH LPH 7 7 LPH 5.7'. m 7.5' 5. m.5'. m.'. m
Open Motor Pumps High Pressure Pumps Non-Submersible Use Non-Submersible Use In-line use in hot drink dispenser, fountain and fresh water applications. Largely used in water displays / HP open motor Viton shaft seal Stainless steel shaft Aluminum mounting bracket -AA-OM Non-submersible, high pressure, carpet cleaning, dispenser displays, and pressure washers / HP fan-cooled motor Thermoplastic housing Carbon/ceramic shaft seal Double-insulated motor (non-replaceable brushes last 5- hours) Includes bypass adapter UR listed (5) 5-OM Capacity: GPH @ ' LPH @. m Shut Off: 7' (. m) Liquid Temperature: F (9 C) Discharge: /" MNPT ( mm) Intake: /" FNPT & /" MNPT ( mm &.7 mm) Electrical: 5v, Hz,.A Capacity: 7 GPH @ ' LPH @. m Shut Off: ' (.7 m) Liquid Temperature: F (9 C) Discharge: /" barbed OD (9.5 mm) Intake: /" barbed OD (9.5 mm) Impeller: PPS impeller Electrical: 5v, Hz,.5A v, 5/Hz,.A Item # Model Volts Lead Wires 5 -AA-OM 5 ".5 cm Item # Model Volts Lead Wires 5 5-OM 5 5 5-OM " cm " cm Replacement Seal Kit Item # Model 599 5-OM-SK Housing, carbon seal, impeller with ceramic seal and O-ring 7 5 5.5.5 9 7 5 5 5 5 5 5.79
Parts Washer Pumps Submersible Use CAUTION: The low flash point of these combustible liquids does present a moderate fire hazard. Operating the pump fully submerged offers added protection from fire risk. For other solvent handling precautions, consult the material safety data sheet (OSHA- form, or equivalent), for the solvent use. Use only UL approved Metal Parts Cleaning Solvents. The use of fluids such as gasoline, and lower flash point solvents is dangerous and may cause explosions or fire. Solvents other than UL approved metal parts cleaning solvents will void the warranty of this product. Submersible for pumping unheated metal parts cleaning solvent which is UL classified as PJQU /5 HP epoxy encapsulated motor Cast aluminum/polyester housing and screen Viton shaft seal /" (9.5 mm) conduit fitting UR / C-CSA listed Capacity: 7 GPH @ ' LPH @. m Shut Off: 7' (. m) Liquid Temperature: F (9 C) Discharge: /" MNPT ( mm) Electrical: 5v, Hz,.A -EAYS Item # Model Volts Cord Capacity Protection ' 7 GPH @ ' 5 -EAYS 5. m Impedance LPH Submersible for pumping unheated metal parts cleaning solvent which is UL classified as PJQU /5 HP oil-filled motor Cast aluminum housing Viton shaft seal Polyethylene screen /" (.7 mm) conduit fitting UR / C-CSA listed (5, 55) Capacity: 5 GPH @ ' 77 LPH @. m Shut Off: 7.' (. m) Liquid Temperature: F (9 C) Discharge: /" MNPT ( mm) Electrical: 5v, Hz,.A v, 5/Hz,.A Item # Model Volts Cord Capacity Protection ' 5 GPH @ ' 5 -YS 5. m 77 LPH 55 -Y 5 5 -YS '. m '. m -YS 5 GPH @ ' 77 LPH 5 GPH @ ' 77 LPH 7 5.5.5 7 5.5.5 5 5 5 5 5
Parts Washer Pumps Specialty Pumps Acid Pumps Submersible Use Submersible or In-line Use Submersible for pumping unheated metal parts cleaning solvent which is UL classified as PJQU / HP oil-filled motor Cast aluminum housing Viton shaft seal Nylon screen /" (.7 mm) conduit fitting UR / C-CSA listed E-NYS Submersible for pumping water or machine oils. In-line when pumping weak acids and chemicals, fruit juices, cleaning solvent, anti-freeze and fluids with a ph factor of to 7 / HP oil-filled motor Epoxy coated cast aluminum housing Inner and outer Viton shaft seals Adapter included for /" (.7 mm) barbed intake E-NDVR Capacity: GPH @ ' LPH @. m Shut Off:.' (. m) Liquid Temperature: F (9 C) Discharge: /" MNPT ( mm) Intake: Hooded Electrical: 5v, Hz,.7A Item # Model Volts Cord Capacity Protection ' GPH @ ' 5 E-NYS 5. m LPH Capacity: GPH @ ' LPH @. m Shut Off:.' (. m) Liquid Temperature: F (9 C) Discharge: /" MNPT ( mm) Intake: /" FNPT (9.5 mm) Electrical: 5v, Hz,.7A Item # Model Volts Cord Capacity Protection 5 E-NDVR 5 '. m GPH @ ' LPH 5 5 75 5.5 5 5 75 5.5.5.5.5.5.5.5 5 5 5 5 5 5 5 5
Solar heating, heat exchange units, and open or closed commercial and domestic hot water recirculating systems /5 HP motor (dual fan-cooled, 55 RPM) Bronze pump head Oversize sleeve bearings Stainless steel shaft and magnet separator Silicon O-ring GPH @ ' LPH @. m Shut Off: ' (. m) Liquid Temperature: F ( C) Discharge: /" MNPT (.7 mm) Intake: /" MNPT (9.5 mm) Impeller: PPS Electrical: 5v, Hz,.A Maximum system pressure designed for 5 PSIG in closed loop system Indoor use only UR / C-CSA listed Item # Model Volts Lead Wires Capacity Protection 579 CMD--B 5 5". cm CMD--B GPH @ ' LPH @. m Impedance Solar heating, heat exchange units, and open or closed commercial and domestic hot water recirculating systems /5 HP motor (dual fan-cooled, RPM) Bronze pump head Oversize sleeve bearings Stainless steel shaft and magnet separator Silicon O-ring Capacity: 7 GPH @ ' LPH @. m Shut Off: ' (. m) Liquid Temperature: F ( C) Discharge: /" MNPT (.7 mm) Intake: /" MNPT (9.5 mm) Impeller: PPS Electrical: 5v, Hz,.A Maximum system pressure designed for 5 PSIG in closed loop system Indoor use only UR / C-CSA listed Item # Model Volts Lead Wires Capacity Protection 579 CMD--5B 5 CMD--5B '. m 7 GPH @ ' LPH @. m Thermal overload.5.5.5.5.5..... 5 5.5.5.5.5 5 5 5
Specification Charts Specialty Pumps Item # Model HP Amps/ Watts Performance (GPH @ Height in Feet) Shut Off Cord Weight Dimensions (inches) PSI Volts ' ' 5' 9' ' ' 5' (ft.) (ft.) (lbs) Height Length Width 5 VMC- /5./ 9.5.9 5. 9. 5 -AA-OM /./ 5 55 7. 5 5 5-OM /.5/ 7 5 5 5 5-OM /./ 7 5 " (Leads) " (Leads) " (Leads) List/Cert.....7.9.9.7.9.9 5 -EAYS /5./ 7 7. 5.... 5 -YS /5./7 5 7.. 5.... 5 -YS /5./7 5 7...5... 5 E-NYS /.7/ 55 5 7. 5. 5. 5. 5.5.5 5 E-NDVR /.7/ 55 5 7. 5. 5 5. 5.7.5 579 CMD--B /5./ 5.7 5 5" (Leads) 5.9. 579 CMD--5B /5./ 7 9 5 5. 5.7.9 9