South Elgin & Countryside Fire Protection District

Similar documents
MOBILE FOOD VENDING Food Trucks & Trailers

CORPUS CHRISTI FIRE PREVENTION MOBILE FOOD VENDOR REQUIREMENTS

Minimum Information Required to Process your Special Occasion Application. Parking area Access to site

Tents and Temporary Membrane Structures Packet

Tents and Temporary Membrane Structures Permit Procedure

Outdoor Festival and Special Event Guidelines

REGULATIONS FOR OUTDOOR GATHERINGS AND EVENTS TENTS & MEMBRANE STRUCTURES

All temporary special events held within the City of Orlando must be approved and inspected by the Orlando Fire Department prior to holding the event.

SafetyNet FIRE MARSHAL S OFFICE. Food Booth and Vendor Regulations

EXCELSIOR FIRE DISTRICT

For additional information please contact the Chesapeake Fire Prevention Office at or at

TENTS AND TEMPORARY MEMBRANE STRUCTURES PERMIT PROCEDURE

CITY OF OKLAHOMA CITY SPECIAL EVENT REQUIREMENTS Revised January, 2011

REQUIREMENTS FOR TENTS, CANOPIES & MEMBRANE STRUCTURES

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD

FIRE DEPARTMENT PERMIT GUIDELINES

Dear Exhibitor, To assist in th. and safety issues that you may encounter with your booth.

Note: The event coordinator is responsible for compliance of all regulations.

Note: The event coordinator is responsible for compliance of all regulations.

General Festival Conditions & Temporary Use of Tents Conditions of Approval

Anticipated Date and Time for Completion of Break-Down:

30 DAY TEMPORARY TENT APPLICATION ON EXISTING COMMERCIAL PROPERTY

PLACES OF ASSEMBLY CHAPTER 17

Temporary Use Permit Application Check List

SANDUSKY FIRE DEPARTMENT Fire Prevention Bureau. Dear Prospective Food Vendor:

Township of Upper Providence Office of the Fire Marshal

The City of Temecula Community Services Department

UC Irvine Environmental Health & Safety TITLE: Special Events Program

City of Leduc Fire Services Indoor Special Event Requirements

FIREDEPARTMENT REGULATIONS AND GUIDELINES

FIRE PREVENTION CODE

ATTACHMENT B FIRE CODE REQUIREMENTS FOR EXHIBITS AND SPECIAL EVENTS

FOOD PREPARATION WITHIN EXHIBITS

New Facilities. Minimum Requirements

ICC CODE CORNER 2015 International Fire Code

Canby Fire District 221 S. Pine Street Canby, OR97013 Bus Fax Fire Marshal, Todd Gary

PLANNING AND MANAGEMENT GUIDE for PUBLIC ASSEMBLY EVENTS

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

Calgary Fire Department Indoor Special Event Requirements. August calgary.ca /fire call

M E M O R A N D U M. All Licensed Assisted Living Facilities. Felicia Cooper, Deputy State Fire Marshal Administrator Don Zeringue, Chief Architect

4. Distances to property line, buildings, other tents, parked vehicles and engines;

Clark County Department of Building & Fire Prevention 4701 West Russell Road, Las Vegas, NV (702) FAX (702)

Fire and Life Safety Requirements San Mateo City Special Events

Fire/Life Safety Policy

LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2006 EDITION

SPECIAL AMUSEMENT OCCUPANCIES HAUNTED HOUSE, SCARE HOUSE OR MAZE

Jacqueline Wilmot Fire Protection Engineer NFPA. Road Map for Mobile Food Truck Regulation

Mobile Food Units. A definition of mobile food unit added in OFC Rule 2 is as follows:

CHAPTER 56 EXPLOSIVES AND FIREWORKS SECTION FIREWORKS 1.4G RETAIL STORAGE, DISPLAY, AND SALE

Osceola County Department of Fire Rescue and Emergency Medical Services

HEALTH DEPARTMENT Environmental Health, Mosquito Control, Neighborhood Protection, Stormwater, and Animal Services

REQUIREMENTS FOR EVENTS AND TEMPORARY STANDS AT FAIRS AND SHOWS

PALM SPRINGS FIRE DEPARTMENT REGULATIONS FOR TRADE SHOW EXHIBITORS, CONVENTIONS AND SPECIAL EVENT GATHERINGS BASED ON THE 2010 CALIFORNIA FIRE CODE

CITY AND COUNTY OF DENVER POLICY DENVER FIRE DEPARTMENT

Fire and Life Safety Review Form

CITY AND COUNTY OF DENVER POLICY DENVER FIRE DEPARTMENT

SEMINOLE FIRE DEPARTMENT TENT PERMIT CONDITIONS

FIRE AND LIFE SAFETY REQUIREMENTS FOR SPECIAL EVENTS STANDARD

September 1, Sincerely, Mike Montgomery Fire Marshal. M.S. Montgomery Fire Marshal

Fire Safety Guidelines and Requirements CenturyLink Field and Event Center June 2015

COMPLIANCE WITH THIS PUBLICATION IS MANDATORY

MOBILE FOOD VENDOR DEFINITION & FIRE INSPECTION INFORMATION

Exhibits and Trade Shows Permit Application

Family Foster Home Fire Safety Evaluation Checklist Instructions

SACRAMENTO FIRE DEPARTMENT FIRE PREVENTION DIVISION FIRE DEPARTMENT DEVELOPMENT SERVICES UNIT CONTRATOR INFORMATION PACKET

SPECIAL EVENTS INSTRUCTIONS AND REQUIREMENTS Must apply at least 2 weeks PRIOR to Event Date

North Liberty Fire Department Permit Application Temporary Storage & Use of LPG

FIRE & SAFETY REGULATIONS (Updated )

GUIDELINES FOR EMERGENCY PLANNING AND PREPAREDNESS. High-Hazard

Community Festival Permit Application - Cypriot Community of Toronto Inc. - Cultural and Wine Festival June 23 and 24, 2007

OCFEC Fire Marshal Summary Report

2018 IFC Update. Based on the 2018 International Fire Code, (IFC ) Goal. Objectives. Content

MULTI-LEVEL & COVERED BOOTH CONDITIONS

FORM MUST BE SIGNED AND RETURNED FOR VENDOR PARTICIPATION

FIRE PREVENTION AND PROTECTION*

ARKANSAS FIRE PROTECTION LICENSING BOARD ACT 743 OF 1977

McCormick Place Fire Safety Regulations

PERMIT APPLICATION Central Pierce Fire & Rescue 902 7th Street NW - Puyallup, WA Telephone (253) Fax: (253) 538.

Table OUT OF SERVICE. Building Fire Video 1/15/ Inspection, testing and maintenance. Standards Further Referenced by FCNYS

Fire Safety Plan Information. For Construction and Demolition Sites

2009 INTERNATIONAL FIRE CODE AMENDMENTS

School Fire Safety Checklist

FIRE SAFETY GUIDELINES

STATE OF MARYLAND DEPARTMENT OF STATE POLICE OFFICE OF THE STATE FIRE MARSHAL

International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures

SAFETY GUIDELINES INDIANA STATE FAIRGROUNDS & EVENT CENTER. Fairgrounds Security:

FIRE INSPECTION GUIDELINES FOR FOSTER GROUP HOME PARENTS Effective June 1, 2002, Update September 2011

Washington State Convention Center Fire Safety Guidelines

Fort Bragg Fire and Emergency Services Division Fire Safety Survey For use of this form, see FB Reg 420-1, the proponent agency for this form is DES.

Saturday, September 9 th 2017 ***** NO PETS ALLOWED

Business Fire Inspection. City of Guadalupe

VENDOR AGREEMENT PACKET

SALT LAKE OFF-ROAD EXPO 2018 Sponsor Information Friday-Saturday April 27 th & 28 th 2018 South Towne Expo Center Hall 5 Off-Roaders Unite!

STANDARD DETAILS & SPECIFICATIONS Spec No _SI _ Rev. Date 10/20/11

Table of Contents CHAPTER 10 ADMINISTRATIVE RULES FOR CERTIFICATION OF CHILD CARE FACILITIES FIRE STANDARDS FOR FAMILY CHILD CARE HOME

CITY OF TOLEDO. Paula Hicks-Hudson. MAYOR Our Division s web-site can be accessed 24/7 at

GLENDALE FIRE DEPARTMENT FIRE MARSHAL S OFFICE

BYLAW 5542 *******************************************************************************

JOINT CODE INTERPRETATION

CITY OF TOLEDO. MICHAEL P. BELL MAYOR Our Division s web-site can be accessed 24/7 at

Transcription:

MARY VAN WINKLE President RONALD R. BOHLMAN Secretary JEFFREY A. SPEYERS Treasurer South Elgin & Countryside Fire Protection District 150 WEST STATE STREET SOUTH ELGIN, ILLINOIS 60177 Business Phone (847) 741-2141 * Fax (847) 741-2184 JOSEPH M. CLUCHEY Trustee JEFFREY T. THERIAULT Trustee WILLIAM B. SOHN Fire Chief In the fall of 2016 the South Elgin & Countryside Fire Protection District adopted and amended an ordinance on special events, temporary cooking, and mobile cooking operation. The District realized an increase of large group events, the use of temporary and mobile food units, and recognized the need to update this policy. The District is utilizing codes and standards that have already been adopted in the 2015 International Fire Code, the latest updates to the National Fire Protection Association standards, along with some amended codes and standards from other agencies that have proven to work and we feel would assist our District. As you plan this year for your event please notice these new changes and plan accordingly. Doing so will prevent misunderstanding, and possible delays to your event. The most noted changes will be to include the requirement of an automatic external defibrillator (AED) as part of your medical needs, and the implantation of Crowd Managers (online course). Please use the following information to assist you in safely planning your event. If you have any questions please contact Fire Inspector David Carlson at 847-531-8641 or Assistant Chief Steve Wascher at 847-741-2141. In the matter of life and property, Dave Carlson, Fire Inspector

SOUTH ELGIN COUNTRYSIDE FIRE PROTECTION DISTRICT Special Events, Temporary Cooking and Mobile Cooking Operation Policy 1. Policy Statement The South Elgin & Countryside Fire Protection District provides Fire and EMS protection to many different local and county agencies. During special events and public assemblies, it is the intent of the South Elgin & Countryside Fire Protection District to preserve the safety and welfare of its residents and visitors within the District s boundaries. The South Elgin & Countryside Fire Protection District has developed this Special Event policy to provide these fire and life safety requirements to insure it reaches its goals. This policy does not supersede any other requirements or permitting with other agencies within our Fire District. Exception to this policy- Existing Assembly group A structures with a current occupancy permit, where Fire and Life issues are covered under the codes and standards adopted by the Fire Protection District, and the occupancies are compliant to those codes. 2. Authorization Where the South Elgin fire code official determines that an indoor or outdoor gathering of persons has an adverse impact on public safety through diminished access to buildings, structures, fire hydrants and fire apparatus access roads or where such gatherings adversely affect public safety services of any kind, the South Elgin fire code official shall have authority to order the development of or prescribe a public safety plan that provides an approved level of public safety and addresses the following items: Emergency vehicle ingress and egress Fire Protection Emergency egress or escape routes Emergency medical services, to include onsite medical services Public assembly area The directing of both attendees and vehicles, including the parking of vehicles Vendor and food concession distribution The need for the presence of law enforcement The need for fire and emergency medical services personnel (2015 International Fire Code 403.12.2) The South Elgin & Countryside Fire Protection District also has the authority to: a. Deny the permit if the District determines that the information supplied on the application indicates that the measures taken by the applicant to ensure the public health, safety, and welfare are inadequate. b. Deny the permit if the District discovers that any false or misleading information has been submitted within the application. c. The District may restrict or deny any permit if the District determines that the proposed attendance exceeds the capacity of the proposed site and /or facility. The District can also charge an additional submittal fee if a corrected application is required (double the initial event review fee).

d. A special event may be suspended by the District, or other public safety agencies at their discretion, in the event of severe weather, public emergency, or if there is a reasonable determination that the special event poses a serious threat to the health, welfare or safety of the public. The Fire Protection District is not to be held liable for any financial loss or property damage due to events beyond our control. 3. Definition of Special Event Any activity on public or private property that is open to the general public that brings together a total of 250 or more people. Small event 250-499 attendance Large event 500 and over Attendance shall mean the total amount of people expected or estimated for the day of the event. 4. Definition of Mobile or Temporary Cooking Any cooking facility, apparatus or equipment, being operated on a one-time or interim basis, or for less than 90 days in the same location, other than at a fixed location, building or structure which has been inspected and permitted under another code or ordinance, inclusive of selfpropelled trucks and vehicles, trailered units, push carts, equipment located under cover of awning, canopies or pop-up tents, or other structures for which a building permit or occupancy permit has not been issued. 5. Insurance Requirements The South Elgin & Countryside Fire Protection District shall also be named as additional insured; the minimum coverage liability will be $1,000,000 per occurrence and $2,000,000 in aggregate. The insurance certificate is to be submitted with the event packet. 6. Special Events permit cost The cost of special event permit, for purpose of fire and life safety is $75 for small events and non-profit organizations, large events are $150. This cost covers plan review fee and initial inspection. Other costs that may include: Additional inspections, 1 st free, 2 nd re-inspection $75 and 3 rd re-inspection $150 Fire and EMS personnel standby, pyrotechnics display standby: $250 per hour for each vehicle $75 an hour per Firefighter/Paramedic 7. Requirements for permit ( provide the following in a packet) - South Elgin & Countryside Fire Protection District, Gathering/Special Event Permit form - Proof of insurance (see #4) - Emergency Action Plan (EAP) Name of event, location, dates and times, representative info, and emergency notification info Severe weather plan Fire plan Medical Emergency plan

Security or law enforcement plan Emergency vehicle access and site evacuation plan. Event area site plan must include the following items: An outline of the entire event area including the names of all streets or areas that are part of the event and the surrounding area. If the event involves a moving route of any kind, indicate the direction of travel and all street or lane closures. The location of fencing, barriers and/or barricades. Indicate any removable fencing for emergency access. The provision of emergency access lanes throughout the event venue. The location of first aid facilities and ambulances. The location of all stages, platforms, scaffolding, bleachers, grandstands, canopies, tents, portable toilets, booths, beer gardens, cooking areas, trash containers and dumpsters, and other temporary structures. Generator locations and/or source of electricity. Placement of vehicles and/or trailers. Exit locations for outdoor events that are fenced and/or locations within tents and tent structures. Other related event components not listed above. 8. Crowd Managers One (trained) crowd manager must be provided for every 250 attendees (approved class). Some of the duties of crowd manager but not limited to: Conduct an inspection of the area of responsibility, identify and address any egress barriers issues. Conduct and inspection of the area of responsibility to identify and mitigate any fire hazards. Verify compliance with all permit conditions, including those governing pyrotechnics and other special effects. Direct and assist the event attendees in evacuation during an emergency. Assist emergency response personnel where requested. Any other duties required by fire code official. Any other duties as specified in the fire life safety plan. 9. Fire and Life safety requirements Medical and first aid: o Small Event (250-499 attendance): 1-2 Trained medical personnel with supplies to perform basic life support (BLS) and have an AED available for use o Large Event (500 or more): 2-4 Trained medical personnel with supplies to perform basic life support (BLS) and have an AED available for use The District has the right to require additional medical requirements if special needs arise.

Tents: 1. All tents used for cooking or containing heat generating devices, shall be made of fire retardant material. Proof of Certificate of Approval by accepted testing laboratory may be required. 2. All tents that are non-fire retardant must be 20 feet away from a cooking tent or heat producing equipment. 3. A maximum of 3 side walls on cooking and vending tents shall be allowed. 4. Cooking shall not take place within tents occupied by the public. 5. Tents and canopies are not to be used as a shelter during time of severe weather. 6. Temporary food cooking and serving operations shall not block fire access roads, fire lanes, fire hydrants, or other fire protection devices and equipment. 7. No flammable liquids or highly flammable materials shall be stored within 20 feet of any tents, booths or canopies used for cooking or vending of any food, or enclosures containing heat-generating devices (exceptions such as an approved 20 lbs. maximum LPG cylinder may be authorized by the Fire District). 8. Inspection of the tent covers fire and life safety. Inspection for proper installation and the structure is covered by the Village/County building department. *Please note: Tents, temporary stage canopies and membrane structures shall comply with 2015 International Fire Code Chapter 31. The provisions of section 3103 are applicable only to temporary tents and membrane structures. The provisions of section 3104 are applicable to temporary and permanent tents and membrane structures. Other temporary structures shall comply with the 2015 International Building Code. Cooking equipment: 1. All interior cooking equipment shall be of an approved type, and open-flame cooking shall be located a minimum of 18 inches from back/side tent materials. 2. All cooking equipment shall be placed on a hard, level, flat flooring (example 3/8 plywood). 3. Camping type stove may be used with propane or butane fuel only, and approved by the Fire Marshal or his representatives. 4. Max amount fuel of inside each tent/booth shall not exceed 20 lbs. cylinder. 5. All compressed gas cylinders shall be secured in an upright position 6. All spare or empty propane tanks shall be stored outside the tent/booth. Fuel tanks shall be protected from damage and secured in an upright position. 7. The Fire Inspector may require vendors to demonstrate a test of all connections for leaks utilizing a soap water solution. 8. All charcoal cooking will be done outside and 10 feet from any tent or combustible structures. 9. Coals shall be disposed of in a metal container with a metal lid and marked hot coals only and be approved by Fire Marshal or his representatives. Fire Extinguishers: 1. Each food vender s booth shall be equipped with a fire extinguisher with a minimum rating of 2A: 10B:C, minimum 5lbs.

2. Booths with deep fat fryer equipment cooking shall be equipped with an extinguisher rated for class K fires. 3. When wood or charcoal is being used a minimum of one 2A portable fire extinguisher or an approved hose shall be provided 4. Vender booths that have heat producing equipment (electric or open flame) shall have a minimum rating of 2A:10B: C fire extinguisher, minimum 5lbs. 5. Each generator shall be provided with a fire extinguisher with a minimum 10lbs. ABC rating. The extinguisher shall be located near the generator and accessible at all times. 6. All fire extinguishers shall be serviced and tagged annually by a state-licensed contractor, or show proof of its purchase within 1 year timeline. Electrical Power: 1. Extension cords shall be of a grounded type, and approved for exterior use. 2. Cords with multiple outlets must have surge or GFI protection. 3. Protect cords from water and wear, according to good electrical use practices. 4. Portable generators shall be positioned so that the exhaust is directed at least 5 ft in any direction away from any openings or air intake, means of egress, away from any building, mobile or temporary cooking operation. Mobile Cooking: 1. An approved carbon monoxide detector shall be installed where mobile cooking operations are performed in an enclosed area. 2. When multiple mobile food trucks are located at the same location, there must be a 10 foot separation between each vehicle. 3. When mobile food trucks or trailers are parked, it must be secured to prevent accidental movement with wheel chocks or blocks 4. All mobile trucks and trailer units must comply with codes and standards related to their operations set forth in; NFPA 96 (commercial cooking hood), NFPA 70 (electrical) and NFPA 58 (LP Gas).