Xcel HEATBANK Thermal Store The solution to multi-fuel heating. Renewable Energy Solutions

Similar documents
HEATBANK Xcel Thermal Store The solution to multi-fuel heating. Renewable Energy Solutions

Renewable Energy Solutions

XCEL HEAT BANKS Installation Instructions. Thermal Integration Ltd., 1-3 Wealdstone Road, Sutton, Surrey SM3 9QN.

TORRENT STAINLESS ONE NAME. EVERY SOLUTION. OPEN VENTED THERMAL STORE PROVIDING HEATING AND MAINS PRESSURE HOT WATER

S T O R E R A N G E C Y L I N D E R & G R A N T FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS

UN-VENTED & VENTED STAINLESS STEEL HOT WATER CYLINDERS

THERMAL STORE MAINS PRESSURE SYSTEM

Kills bills. How Vaillant technologies reduce home heating bills

Mains Pressure Hot Water from an existing vented copper cylinder... Allows the cold water tank to be removed, freeing loft space.

Renewable Range Cylinders providing a perfect partnership with renewable energy inputs SUPPLIERS TO THE MERCHANT TRADE FOR OVER 40 YEARS

TORRENT ECO ONE NAME. EVERY SOLUTION. OPEN VENTED THERMAL STORE PROVIDING HEATING AND MAINS PRESSURE HOT WATER

New Zip AquaFlo. Stainless steel cylinders for mains pressure hot water

THERMAL STORE MAINS PRESSURE SYSTEM

ADVANCE UNIVERSAL MULTI-FUEL THERMAL STORE

Mains pressure hot water for fast filling baths and powerful showers Simultaneous supply of water to all bathrooms Long life low maintenance hot

INTRODUCTION STORAGE PRIOR TO INSTALLATION. Expansion Vessel Hose. Part No High Flow Rate Inlet Control Set. Part No.

QUALITY DESIGN. BUILT-IN RELIABILITY. CYLINDERS. The complete range of Warmflow Cylinders.

VENTED CYLINDER RANGE

Torrent ECO. The final piece in your heating and hot water system. Open vented thermal store providing heating and mains pressure hot water

Amptec. Electric flow boiler

STAINLESSLITE PLUS ONE NAME. EVERY SOLUTION. UNVENTED MAINS PRESSURE AND VENTED WATER STORAGE CYLINDERS

Stainless Steel Unvented Cylinders

STAINLESSLITE PLUS ONE NAME. EVERY SOLUTION. UNVENTED MAINS PRESSURE AND VENTED WATER STORAGE CYLINDERS

Exceeding the Standard

STAINLESSLITE ONE NAME. EVERY SOLUTION. UNVENTED MAINS PRESSURE AND VENTED WATER STORAGE CYLINDERS

unistor High performance unvented stainless steel cylinder range

PANDORA HEAT BANKS OXFORD BROOKES, HARCOURT HILL. Operation and Maintenance. THERMAL INTEGRATION LTD. Tel: Internet:

H ot Wa te r Syste m s. Copper Hot Water Products. Total Hot Water Solutions

H o t Wa te r Syste m s. Ultrasteel. Unvented Hot Water Cylinders. Exceeding the Standard

Exceeding the Standard

AquaCyl solar system solar water heating solution for the larger home with greater hot water demand (2 or more bathrooms in use simultaneously)

Total Hot Water Solutions

TORRENT STAINLESS INSTRUCTION MANUAL DESIGN, INSTALLATION & SERVICING ONE NAME. EVERY SOLUTION.

unistor High performance unvented stainless steel cylinder range

Cistern-fed water heating

Hot Water Supply. Dr. Sam C M Hui Department of Mechanical Engineering The University of Hong Kong

WATER HEATERS. Simplicity, performance, comfort... Hydraflo. Unvented Cylinders. 125 to 300 litres, directly or indirectly heated.

H o t Wa te r Syste m s. Tribune HE. Unvented Hot Water Cylinders. Making Life Simpler

hxi High Efficiency Heating Only 24hxi hxi High Efficiency Heating Only 30hxi hxi High Efficiency Heating Only 38hxi

Recommendations texts (9.82) to be used on Energy Report in Scotland 18 July 2008

Solar thermal domestic hot water system

Thermaflow. Creating Excellence, Building Reputation Unvented Water Storage From The Experts... Thermaflow Thermaflow. Thermaflow.

Why Vaillant? Home Heating Guide. Because they can reduce our heating bills and our carbon footprint

ENERSTORE. Vented Hot Water Storage System INSTRUCTIONS PLEASE LEAVE WITH HOUSEHOLDER

THERMflow Thermal Store Cylinders

H o t Wa te r Syste m s. Senator Electric Flow Boilers. Making Life Simpler

UNVENTED STAINLESS STEEL CYLINDERS

Appendix T: Improvement measures

Design, Installation & Servicing Instructions. A total hot water and heating thermal store that can also make the most of renewable energy

ADVANCE ECB ELECTRIC COMBINATION BOILER

Appendix T: Improvement measures for Energy Performance Certificates

Re n ewa b l e s. Tribune HE. Unvented Hot Water Cylinders. Making Life Simpler

H o t Wa te r Syste m s. Tribune HE Unvented Hot Water Cylinders. Making Life Simpler

INTERCYL. INTERNAL EXPANSION EXCELLENCE

Series 1000 & Storage Water Heaters

H o t Wa te r Syste m s. Unvented Copper Hot Water Cylinders for Heat Pump and Solar Input. Exceeding the Standard

Installation and Commissioning Manual

Design, Installation & Servicing Instructions. A total hot water and heating thermal store that can also make the most of renewable energy

H o t Wa te r Syste m s. Tribune HE Unvented Hot Water Cylinders. Making Life Simpler

SHERPA DHW 75. Th e multifunctional air-water split heat pump. COP > 4 DHW 75 C

CUBEflow Thermal Store Tank

SOLAR HEATING SYSTEMS

DOMESTIC HOT WATER AND CENTRAL HEATING SYSTEM

Water Heating Systems

A comparison of Pandora Heat Bank Thermal Stores to Unvented Hot Water Cylinders HIGHER PRESSURES AND FLOW RATES

JASPI GTV & Oval thermal storage

The world s most advanced direct electric water cylinder

Improvement schedule for SAP May 2014 Note 8 revised 29 May 2014 NI high/further measures corrected 17 July 2014

Alpha FlowSmart 25 and 50

Commercial Hot Water Solutions Ltd.

AquaFlo II. Issue 3 December Please read these instructions carefully before commencing installation of the AquaFlo unvented water heater

EXCELLENCE IN HOT WATER TECHNOLOGY CYLINDER PRODUCT GUIDE

Efficiency Maximiser for Solid Fuel Central Heating

Instructions for Use Installation and Servicing

Heat Recovery Solutions. In stainless steel

2015 PRODUCT RANGE GUIDE

Jaspi GTV and Jaspi Oval. Jaspi Oval thermal storage tanks

A-Class. A-Rated Homes with Dimplex heat pumps. The name you can trust. Building Regulations and Part L Compliance made easy with Dimplex. dimplex.

ROTEX Sanicube: Combination of Hot water storage tank and Instantaneous heater. ROTEX Sanicube - The hygienic hot water storage tank. The heating!

EFFICIENCY THERMAL STORAGE SYSTEMS

H o t Wa te r Syste m s. Copper Hot Water Products. Exceeding the Standard

TORRENT ECO INSTRUCTION MANUAL DESIGN, INSTALLATION & SERVICING ONE NAME. EVERY SOLUTION.

Unvented Hot Water Systems for the Professionals

Combined electric boiler and domestic hot water store

Grant Wave range. High efficiency direct and indirect hot water storage solutions

maximise the sun s energy with warmflow solar Warmflow Solar

Risk Assessment and Control Measures for Household Hot Water Systems

Saving energy comes naturally to us.

Installation, Operating and Servicing Instructions

Tried. Tested. Trusted.

Unvented water heaters

INFORMATION BOOKLET NRG Zone Models 2,3 and 4 Designed, Developed and Manufactured in Ireland

CPC-150-ABIAB. Important Installation Notes.

Link-Up. Solid Fuel Association Guide to Central Heating.

ELECTRIC BOILERS. RANGE 1kW to 980kW ABOUT ATLANTIC ELECTRIC DOMESTIC HOT WATER HEATERS. WATER HEATERS 445 to 7520ltrs/hr

Installation, Operating and Servicing Instructions

UltraOil Condensing Oil Boiler

Unvented water heaters

Efficient heating that won t cost the earth

Redring Powerstream Electric Flow Boilers. Efficient, safe and convenient electric space and water heating

Transcription:

Xcel HEATBANK Thermal Store The solution to multi-fuel heating Renewable Energy Solutions

Description of Standard Options Xcel HEATBANK Thermal Store Size and Capacity 01 02 The Xcel HEATBANK thermal store comes in a number of standard sizes. All are manufactured from Duplex stainless steel, and come complete with finished outer casing and injected CFC free polyurethane insulation. 165 litres: Ø535mm x 1200mm Cased 220 litres: Ø535mm x 1500mm Cased 247 litres: Ø535mm x 1800mm Cased 300 litres: Ø560mm x 1800mm Cased 390 litres: Ø660mm x 1600mm Cased 500 litres: Ø660mm x 1835mm Cased Special sizes and casing finishes on request. Domestic Hot Water The basic concept behind all of our HEATBANK thermal store systems is the use of a plate exchanger to generate mains pressure hot water. This method of generating hot water allows the store to remain unpressurised and open vented, while providing 9 bar hot water at up to 45 litres per minute. The assembly comes factory fitted and wired, including plate heat exchanger, flow switch, pump and thermostatic mixing valve for control of tap supply temperature. 03 24 Hour Electronic Hard Water Protection Protects the water system and plate heat overheat function exchanger from limescale even when there is no water flow. The Hydropath HS38A model is used as standard, and is factory fitted and wired. Note: This option is in addition to the Domestic Hot Water option. The other big advantage of this method is that it does not require unvented qualifications to install, and there is no requirement for annual maintenance. 04 Secondary Return Pump On installations where a hot water loop is used to prevent dead-legs in supplies to taps, the option of a factory fitted secondary return pump is offered. This includes a bronze pump, non-return valve and pipe thermostat for control of the pump. A Wilo Star Z15 pump is used as standard with other models available on request. Note: This option is in addition to the Domestic Hot Water option. 05 Direct Open Vented Boiler Assembly (up to 35kW) Upgrade available for boilers over 35kW When connecting a boiler to the Xcel HEATBANK thermal store, the standard option is to use the GX direct connection method. This uses a return mixer assembly to control the return temperature to the boiler and ensure efficient condensing recovery from the top down. The top of the store is always heated first, at full boiler output, providing hot water within minutes from a cold start. It also allows the user to decide how much of the store should be heated by the boiler (and hence how much of the store is left for alternative heat sources). Option includes fitted return mixing valve and cylinder thermostat for boiler control. Also used with pumped solid fuel appliances using separate overheat protection as required.

06 Indirect Sealed Boiler Assembly (up to 28kW) For the indirect connection of pressurised boiler systems via a plate heat exchanger recovery system. Provides higher heat transfer rates than a coil, and top-down recovery. Option includes factory fitted plate heat exchanger, pump, regulating valve, and a single fitted cylinder thermostat for boiler control. 07 Additional Thermostat & Relay for Buffered Boiler Operation Where a boiler is used to heat up the Xcel HEATBANK thermal store, the standard options provide for one cylinder thermostat. As a further option the Xcel HEATBANK thermal store can be fitted with two cylinder thermostats that are connected together using a relay to provide a buffering function. The top thermostat is used to turn on the boiler, with the bottom thermostat providing the off signal. This prevents boiler cycling by effectively holding off the boiler until a set volume requires heating. The boiler will then fire in one longer continuous burn until this section of the store has been recovered. As stored water is used up for heating or hot water the boiler remains off until again there is sufficient volume to be reheated. The option includes factory fitted thermostats as well as the wiring for the relay. Note: This option is generally in addition to the Direct or Indirect Boiler Assemblies. 08 Additional Thermostat for Boiler Economy Mode Where a boiler is used to heat up the Xcel HEATBANK thermal store from the top downwards, this option provides for an Economy Mode, where only the very top section of the Xcel HEATBANK thermal store is reheated. This is useful for ensuring hot water for sinks and single showers, while leaving the majority of the store for alternative heat sources. Thermostat and wiring included. Note: This option is generally in addition to the Direct or Indirect Boiler Assemblies. 09 Additional Thermostat for Overheat Function 10 Additional Fitted Sensor Pockets To provide a basic form of overheat protection an additional thermostat can be fitted for the activation of central heating to remove excess heat from the Xcel HEATBANK thermal store. This is always recommended when using a wood burner. Any spare bosses on the Xcel HEATBANK thermal store can be factory fitted with spare sensor pockets for use with site fitted thermostats or sensors. 6mm x 100mm pockets are used as standard with alternatives on request.

11 Standard Pump Assembly 11A Boiler, 11B Heating, 11C Underfloor Heating For boiler circuits and central heating circuits there is usually a requirement for a fitted circulating pump. The standard pump assembly option can be applied to all circuits fed to and from the store, and includes a Wilo 6m head pump, pump valves, fitting and wiring. 12 High Flow Pump Assembly 12A Boiler, 12B Heating, 12C Underfloor Heating For boiler circuits and central heating circuits that require a pump larger than a standard circulation pump, this option includes a pump capable of delivering up to 100 litres per minute at peak flow, and a peak pressure of 6.8m head. Pump valves, fitting and wiring also included. 13 Power-Free Overheat Protection via Discharge This option provides overheat protection of over 12kW, which does not rely on pumps or electricity, using a retro-fit coil. When the stored water reaches 95 C a factory fitted valve opens to allow cold mains water to run through the coil, providing a cooling effect, then off to drain. A pressure reducing valve is fitted for regulation 14 Indirect Sealed Central Heating Assembly (up to 28kW) For pressurised central heating circuits this option uses a plate heat exchanger to transfer heat from stored water into the heating circuit. Identical to Option 6, except the pump is reversed, pumping down, and no fitted cylinder thermostat. It is very well suited to wood burner installations where a discharge is preferable to dump radiators. It is also suited to solar systems where stagnation of solar panels is not desired. 15 Underfloor Heating Temperature Control Valve - 28mm To control the temperature of water fed to a central heating circuit, this option provides a fitted 28mm Thermostatic Mixing Valve (Reliance Water Controls), 20 C to 65 C range. 16 Immersion Heater 3kW to 9kW 16A 3kW, 16B 6kW, 16C 9kW To provide electrically heated hot water, this option includes a fitted 3kW Immersion Heater, complete with control and overheat thermostats, 20 C to 83 C setting range. 6kW and 9kW options require separate overheat protection.

Suitable for simultaneous connection to: Wood Burners Pellet Stoves and Biomass Boilers Gas and Oil Boilers Solar Thermal Panels Heat Pumps Vented and Sealed Heating Systems including Radiators and Underfloor Heating, as well as High Performance Showers and Multiple Bathrooms Very high quality Stainless Steel Laser Welded Construction Performance guaranteed: 25 year guarantee PATENTS GRANTED: 2402994 (MANUAL FILL SYSTEM), 2352506 (DIRECT BOILER RECOVERY SYSTEM), 2470748 (OVERHEAT PROTECTION SYSTEM) AND 2463512 (COMBI-BOILER RECOVERY AND PRE-HEAT)

Xcel HEATBANK Thermal Store Technical specification: Capacity: 210, 250, 300, 350, 475 litres Boss Span: 70 Material: Duplex Stainless Steel Insulation: 40mm CFC Free Foam Bosses: Solar Coil: 20 x 3 4 Female 2 x 3 4 Diffuser Tubes 2 x 2 1 4 Female 2 x 1 1 2 Female 1m 2 Finned Stainless Steel Casing: Test Pressure: 9 Bar Domestic Hot Water (via PHE): Coated Steel 150kW Peak (45 lpm) 9 bar pressure. Drinkable The key to the Xcel HEATBANK is its versatility For twenty years we have been manufacturing both standard and bespoke hot water systems, combining just about every type of heat source there is available to drive central heating and hot water for domestic properties. The Xcel HEATBANK thermal store standardises the whole approach, providing design features that allow any possible combination to be made using a standardised product. In its most basic form the store can act as a buffer system, used purely for central heating. Large 1½ bosses allow the largest of domestic wood burners to be comfortably connected using gravity circulation, with numerous other bosses for pumped circuits. Even larger 2¼ bosses provide for immersion heaters as well as retro-fit coils (mainly used for overheat protection). A large 1m² coil is provided as standard for connection of solar panels (or any other pressurised heat source). One can then add the PHE (plate heat exchanger) option to generate mains pressure hot water to run multiple bathrooms using high pressure mains water, without the need for unvented certification or annual maintenance. Further options provide fitted controls for the use of boilers of all types (sealed and vented) as well as heat pumps. Control options include pump assemblies, thermostats, programmers and timers, and control valves. Both radiators and underfloor heating can be run simultaneously, and the store is configured in such a way that low temperature loads (e.g. underfloor heating) can run off low temperature heat sources (e.g. heat pump) while high temperature loads (e.g. radiators) run using higher temperature heat sources (e.g. wood burners or boilers). Everything working in perfect harmony. Recommended by most well known wood burner manufacturers Contact: 0800 90 20 220 // 01787 880 333 Email: sales@specflue.com www.heatweb.com For a free online design and quotation please visit: www.systemdesigner.co.uk 8 Curzon Road, Chilton Industrial Estate, Sudbury, Suffolk, CO10 2XW