Radio fire warning panel SRC 3000

Similar documents
CSP-204 CSP-208 CSP-104 CSP-108

Dec Wirsbo CoSy Radio. Installation and Operating Instructions

External Wireless Sounder

Section 9 System Operation

Zerio Plus EDA-R6000 Radio Combined Optical Smoke Detector and Sounder Installation Instructions

External Wireless Sounder

Section 8 System Operation

Temporary wireless battery operated fire system from Channel Safety Systems

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

KNX module for smoke alarm devices Dual/VdS and Q-Label (Order no )

Telemetry Communications Device. Installation Guide. Interface for the Emizon managed network. Issue 1: February 2008

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

SCHMIDT LED Measured Value Display MD Instructions for Use

THE EVOLUTION OF CONTROL APP & CLOUD PORTAL

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

Contents 1 Set Up 2 Gateway information 3 Operation of the App 4 Troubleshooting Description of sensors. 1 Set Up. 1.1 Connect the Gateway

User Guide. HTM Nurse Call. In the event of requiring assistance, please contact your Installer/Supplier.

Zerio Plus EDA-D6000 Radio Combined Heat Detector and Sounder Installation Instructions

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

Independent Zone Control (I.Z.C.)

All-In-One Wireless Security System V1.0. Model #: MG Reference and Installation Manual

Installation, Operating and Maintenance Manual

All-In-One Wireless Security System V1.0. Model #: MG-6060

Installation & Operating Instructions

Contents. Glossary

ZERIO PLUS EDA-Z5008, Z5020 & Z5100

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock.

Fire Control Panel FCP dc3400 SC

ECO N DATE DESCRIPTION OF CHANGE CHG

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

Operating instructions SENTRI4 Control panel based Fire detection and alarm system

Alarm System SECURE AS 302

5000 INSTALLATION GUIDE

80 CHANNELS WIRELESS RECEIVER WITH LCD DISPLAY M1.1.1-Hx.x-F1.1-ENG [AN] [SPV] MADE IN ITALY INSTALLATION AND USE MANUAL

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

GSM RFID VOICE Alarm System

Building Technologies. FDUL221 en Line tester operating instructions for electricians

i on Compact Security System

SIMPLICITY CO CARBON MONOXIDE DETECTION & VENTILATION PANEL

setting up your wireless system P300W, C300W, D300W and wireless interface Standards NFS NFS EN 54-11

Salamander User Guide

Wireless Call Point ( )

M2500 Engine Controller Installation Manual

SC-F3G User Manual 1.0

status AW1 WiFi Alarm System Printed in China PA : AW1-UM-EN-V1.0 User Manual 2016 Chuango. All Rights Reserved.

Operating Manual RCM420

1126 Series Ceiling Mount PIR Motion Detector

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

Smoke Detector and Siren. Manual

Honeywell. Wireless Rain Gauge with Indoor. Temperature (TC152) USER MANUAL TABLE OF CONTENTS INTRODUCTION 3 PRODUCT OVERVIEW 4 REMOTE RAIN GAUGE 7

EW 40 Wireless Fan Control

user manual Document No , Revision 03 November 2015

APC BC300 Series 40kW 208/450/480V User Guide

600 Range Dialer Installation Manual. Version 1.0

Test Unit GTL 100 for Fire Detectors

one Operating instructions SenTRI ONE panel-based Fire detection and alarm system

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Flopurge TS. Operation Manual

PERMACONN PM1030 Includes DI300. Installation Manual

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Version 1.03 January-2002 USER S MANUAL

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

Long Range Radio Alarm Transmitter

Memcom Emergency Telephone

ANEMOMETER 4403-RF-BAT

ZSC100 Gas Detection and Alarm System Controller

English. Doro CareIP Mobile. User Guide

Operation & Maintenance Manual

Instructions for the fan motor control system with integrated wiring terminals SILVER C

SPECIFICATION: AlarmLine TM INTELLIGENT LINEAR HEAT DETECTION

SYSTEM ENHANCEMENT MODULE

Installation Instructions

CHECKFIRE 210 Detection and Actuation System

Operating instructions Vigilon panel and Network node Fire detection and alarm system

Watchguard WGAP864 User Manual

IQ8Control C Fire Alarm Panel

Operating instructions

ZP2 Series Operation Manual

Flostop TS D7E and A8E. Operation Manual

Wireless Rain Gauge with Indoor Temperature

System 800 Addressable Fire Detection & Alarm System

QA16 Addressable System

Parameterisable compact fault annunciator with permanent display

Product Documentation

Electro-Detectors Page 2. Revision History. EDA-Z Installation and Operation Manual

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Security System. User Guide for the LED Command Center

1. LCD 2. radar antenna (narrow field) 3. radar antenna (wide field) 4. AIR-curtain width adjustment 5. AIR-lenses

Ion Gateway Cellular Gateway and Wireless Sensors

IDS816 User Manual H Issued January 2009

WIRELESS OUTDOOR DUAL TECHNOLOGY MOTION DETECTOR AOD-200

Intelligent Security & Fire Ltd

RGR150 USER S MANUAL. Wireless Rain Gauge with Thermometer and Clock

Honeywell Temperature & Humidity Sensor with LCD

FIRERAY 5000 range USER GUIDE

SonoSelect and SonoSafe Energy Meters

Wireless Weather Station. Table of Contents

2G & 3G GSM Portable PIR Alarm

CW9000 Wireless Fire System. Installation Manual

status AW1 Plus WiFi Alarm System User Manual

Transcription:

Radio fire warning panel SRC 3000 6 zone radio fire warning panel Operating instructions Version 1.2 Art. 32487

detectomat GmbH Headquarter: Phone: +49 (0) 4102-2114-60 An der Strusbek 5 Fax: +49 (0) 4102-2114-670 D 22926 Ahrensburg Hotline: Phone: Please see www.detectomat.com Fax: +49 (0) 4102-2114-9670 Manual no. 53438 Version 1.2-02 August 2011 * Please specify your customer number when contacting the hotline!

Contents Contents 1 Explanation of Operating Instructions... 5 1.1 Purpose of Operating Instructions... 5 1.2 Notes on Operating Instructions... 5 1.3 Further Documentation... 5 2 General Safety Instructions... 6 2.1 Intended Use... 6 2.2 Requirements to be met by operator/installer... 6 3 Product Information... 7 3.1 Summary... 7 3.2 Environmental conditions... 7 3.3 Technical data... 8 3.4 Conformity... 9 3.5 Software version / serial number... 9 3.6 SRC 3000 Radio fire warning panel... 10 3.6.1 Function... 10 3.6.2 Control and indicating elements... 10 3.7 Radio module 433 bidirectional... 12 3.7.1 Function... 12 3.7.2 Control and indicating elements... 12 3.8 Radio Repeater SRC 3000... 12 3.8.1 Function... 12 3.8.2 Control and indicating elements... 13 3.9 Radio device... 14 4 Installation... 16 4.1 Installation of the radio fire warning panel SRC 3000... 16 4.2 Installation of the 433 bidirectional radio module... 17 4.3 Installation of the radio repeater... 17 5 Logging on radio devices... 18 5.1 Control authorization via PIN code... 18 5.1.1 Entering the PIN code... 19 5.1.2 Editing the PIN code... 19 5.2 Logging on a smoke detector fitted with a radio module onto SRC 3000 panel... 19 5.2.1 Minimising errors during the login process... 21 5.2.2 Deactivation of acoustic signalling on a smoke detector fitted with a radio module... 21 5.2.3 Re-activation of acoustic signalling on smoke detectors fitted with a radio module... 21 5.3 Procedure if radio repeater is used... 22 5.3.1 Logging on the repeater to the SRC 3000 panel... 22 5.3.2 Logging on smoke detectors fitted with radio modules onto the SRC 3000 panel... 23 5.3.3 Logging on radio devices fitted with a radio module onto the radio repeater... 23 6 Deleting radio devices... 25 6.1 Deleting radio device directly from the SRC 3000 radio fire warning panel... 25 Version 1.2 3

Contents 6.2 Deleting radio devices operated via a radio repeater... 25 6.2.1 Deleting a radio module from the radio repeater... 26 6.3 Deleting a radio repeater from the SCR 3000 fire warning panel... 26 6.4 Reset... 27 6.4.1 Performing a reset on smoke detector fitted with a radio module... 27 6.4.2 Performing a general reset on the radio repeater... 27 6.4.3 Performing a general reset on the SRC 3000 panel... 27 7 Configuration... 28 7.1 Configuration of the SRC 3000 panel... 28 7.1.1 Assigning relays to zones... 28 7.1.2 Programming a relay for a "Radio Device Fault"... 28 7.1.3 Programming a relay a "SRC 3000 panel fault"... 29 7.1.4 Programming relays for a common alarm... 29 7.1.5 Programming relays for a common fault... 30 7.1.6 Programming the relay outputs from steady to pulsed... 30 7.1.7 Relay configuration... 31 7.1.8 Programming overview table for sections 7.1.1 to 7.1.7... 32 7.2 PIN configuration for the SUB-D connector... 32 7.3 Special configurations... 33 7.3.1 Parameter 1... 33 7.3.2 Parameter 2... 33 7.3.3 Parameter 3... 33 7.3.4 Parameter 4... 33 8 Commissioning... 34 8.1 Functionality tests... 34 8.1.1 Alarm testing... 34 8.1.2 Testing the communication signal to the radio repeater... 35 9 Operation... 36 9.1 Function keys... 36 9.2 Alarms and faults... 37 9.2.1 Signalling of alarms and faults... 37 9.2.2 Acknowledging alarm/fault messages... 38 10 Maintenance... 39 10.1 Inspection and maintenance intervals... 39 10.2 Maintenance/Service measures... 39 10.2.1 Activating/deactivating the service mode... 39 10.2.2 Automatic disablement of the inspection mode... 40 10.3 Cleaning... 40 10.4 Environmental disposal... 40 Annex 1: List of Abbreviations... 41 Version 1.2 4

Explanation of Operating Instructions 1 Explanation of Operating Instructions 1.1 Purpose of Operating Instructions These operating instructions are intended for technically qualified individuals who have been trained in commissioning, operation, maintenance and repair of the SRC 3000 radio fire warning panel. The user is obliged to comply with these operating instructions, particularly section "2 Instructions on Page 6. These operating instructions contain all relevant technical information required for operating the SRC 3000 radio fire warning panel properly, efficiently and safely. 1.2 Notes on Operating Instructions The following conventions are used in these operating instructions: Lists marked with dots contain information, not working steps. Numbered lists describe a sequence of working steps or hierarchically organized information. Keyboard commands are shown in square brackets, e.g. [Reset]. The following pictograms are used in these operating instructions. They indicate hazards, warnings and important notes. These pictograms must be noted in any case. Warning! Risk of electric shock. Disconnect 230 V power supply before working on live connections. The user is informed about situations and procedures which might result in injuries or even death. Warning! The user is informed about situations and procedures which might result in injuries and/or equipment damage and economic loss. Warning! The user is informed about precautions to be taken when handling electrostatic sensitive components. The user is informed on how to use the product. 1.3 Further Documentation The present operating instructions describe all procedures required for installation, configuration, commissioning, operation, maintenance and repair of the SRC 3000 radio fire warning panel. For further information, refer to the following documents: Operating instructions of radio devices Design of radio smoke warning detectors: DIN 14676 Version 1.2 5

General Safety Instructions 2 General Safety Instructions The SRC 3000 radio fire warning panel is designed to be state of the art within the applicable safety regulations. Non-compliance and wrong installation, commissioning, operation, maintenance, repair or misuse might: present a hazard to life and limb of users or others cause damage to the SRC 3000 radio fire warning panel and other equipment prevent efficient use of the SRC 3000 radio fire warning panel 2.1 Intended Use The SRC 3000 radio fire warning panel is only intended for acquisition, evaluation, display and transmission of measured values detected by the radio devices. The radio repeater is only intended for extending and monitoring the radio range between the SRC 3000 radio fire warning panel and the radio devices and for transmission of the values measured by the detectors/modules. Proper use also includes: compliance with the safety instructions included in these operating instructions compliance with the maintenance and repair instructions use of lithium batteries for the radio devices Any other use shall be considered as not in compliance with the "Intended Use". detectomat GmbH shall not be held liable for any damage or losses resulting from any use of the SRC 3000 radio fire warning panel which is not in compliance with the Intended Use. 2.2 Requirements to be met by operator/installer Installation, commissioning, maintenance and repair of the SRC 3000 radio fire warning panel may only be carried out by companies which have verified that they have the necessary technical skills. Version 1.2 6

Product Information 3 Product Information 3.1 Summary The microprocessor-controlled SRC 3000 radio fire warning panel with life cycle monitoring is designed for connection of up to 100 radio devices. Data exchange is bidirectional. The unit has a frequency working range of 433 MHz. The SRC 3000 radio fire warning panel features an integrated broadcast alarm function. Approx. twenty seconds after an alarm message has been received, this function activates the signal sounders of all radio devices except the radio MCP detector, and the radio input module and the radio repeater, as these components do not feature an internal sounder. It is possible to deactivate the sounder from each radio device permanently if required. An inspection operation mode enables temporary disablement of the broadcast alarm function. In these operating instructions, descriptions in connection with radio devices are based on smoke detectors with radio module. For descriptions relating to the other radio devices, please refer to the corresponding operating instructions. 3.2 Environmental conditions To ensure safe operation of the SRC 3000 radio fire warning panel, it is necessary to ensure certain environmental conditions are met. Environmental conditions Recommendation Room temperature +10 C to +40 C Relative humidity of air Place of installation 40 % to 70 % (non-condensing) no direct sun impact stable, level installation surface suitable for dry, heated rooms Version 1.2 7

Product Information no small or cramped rooms (to prevent radio echo) 3.3 Technical data Radio fire warning panel SRC 3000 Place of installation Dimensions (H x W x D) Weight Colour Display Alarm and Status indicators Supply voltage Operating voltage Nominal current Alarm current Frequency suitable for dry, heated rooms 170 mm x 170 mm x 55 mm ca. 800 g grey LCD display LED 230 V AC / 50 Hz or external 12 V DC supply 12 V DC (max. 13.2 V DC / min. 8.6 V DC) ca. 35 ma (LED operation), max. 120 ma (4 relays in break circuit mode) max. 160 ma (in reference of the operation mode) 433.42 MHz (connection in the ISM-Band) Emergency power supply 8 x 1.5 V type Mignon, LR 6 (Only use original batteries with a normal capacity of at least 2800 mah or certified high quality batteries) Radio transmission power max. 10 mw ERP Acoustic signalling approx. 85 db (1 m) Outputs 4 x relay changeover contact via additional cable F.BZ (32294) SUB-D plug-type connector switching voltage / - current: 30 V AC / 1 A Operating temperature 0 C to +60 C Stock temperature 20 C to +60 C RoHS conform yes Radio Repeater FRP SRC 3000 Place of installation Dimensions (H x W x D) Weight suitable for dry, heated rooms 158 mm x 95 mm x 45 mm ca. 500 g Colour plastic / RAL 9002 Display Supply voltage Operating voltage Closed-circuit current Transmission current Frequency Emergency power supply Radio transmission power LED 230 V AC / 50 Hz via 12V wall power supply 9 V DC ca. 35 ma ca. 90 ma 433.42 MHz (connection in the ISM-Band) 1 x 9 V alkaline block battery IEC 6LR61 (Only use original batteries or certified high quality batteries max. 10 mw ERP Operation temperature 0 C to +60 C Storage temperature 20 C to +60 C Version 1.2 8

Product Information Enclosure type IP 20 RoHS conform yes Radio module FM SRC 3000 Operating voltage 9 V DC Nominal current ca. 40 μa Transmission current ca. 40 ma Frequency 433.42 MHz (connection in the ISM-Band) Radio transmission power max. 10 mw ERP Operation temperature 0 C to +55 C Storage temperature 20 C to +60 C RoHS conform yes Radio smoke detector Dimensions (H x Ø) Operating voltage Closed-circuit current Response sensitivity Air velocity 51 mm (including base) x 100 mm 9 V DC Note: Lithium ions batteries are recommended for use with radio modules. < 16 μa < 0.15 db/m max. 20 m/s Acoustic signalling ca. 85 db (1 m) Nominal temperature 10 C to +60 C Humidity of air Interfaces Enclosure type IP 30 RoHS conform max. 90 % RH non-condensing for radio module FM yes 3.4 Conformity If used as per the Intended Use, the SRC 3000 radio fire warning panel meets the requirements of the R&TTE Directive (1999/5/EC). 3.5 Software version / serial number To display the software version and the serial number of the SRC 3000 radio fire warning panel, proceed as follows: 1 Press function keys [F1] and [F4] at the same time until the software version (e.g. 242) is displayed. If you keep the two keys pressed, after a while the serial number will be displayed instead of the software version. Version 1.2 9

Product Information 3.6 SRC 3000 Radio fire warning panel 3.6.1 Function The SRC 3000 radio fire warning panel is a hazard control panel which offers the following options: administration of up to 100 radio devices which can be divided individually into six different alarm Zones four changeover relay contacts emergency power supply for approx. 60 hours (standby) acoustic signalling via integrated signal transducer monitoring of radio devices for battery capacity, measuring chamber fault of radio smoke detectors and radio link integrity integrated power supply unit three radio repeaters can be used with each SRC 3000 radio fire warning panel data input and output PIN code protected 3.6.2 Control and indicating elements 1 Programming buttons [P1] to [P6] The programming buttons [P1] to [P6] are used for logging on the radio devices (press and release) for configuration (keep programming buttons pressed) To prevent unintentional use, the programming buttons have a recessed design. To press these buttons, use a thin, blunt object, e.g. a ball pen. 2 Fault LED s for radio devices Device Radio device fault Battery Radio device battery fault Radio Transmission (radio) fault with radio devices (communication fault) 3 Status LED s for alarm zones (Zone 1 to Zone 6) Alarm red LED lights up Log-on process red LED lights up (fast flashes) 4 Display Display of alarms and faults, indicating the radio device Zone and address Display of RF field strength with values 000 to 010 (only during the log on of radio devices or when log on procedure is performed again with an existing radio device) Display of programming and special functions 5 Function keys [F1] to [F4] (from left to right Function keys [F1] to [F4] are used for control and programming of the SRC 3000 radio fire warning panel. 6 Status LED s of radio fire warning panel Power green LED is on: Mains voltage present green LED (flashing): Mains voltage not present Panel Fault SRC 3000 radio fire warning panel fault indicator Battery Fault Emergency power fault indicator 7 Status LED s of radio fire warning panel Sounders silenced temporary disablement of all acoustic signal transducers Version 1.2 10

Product Information Tx Maintenance SRC 3000 radio fire warning panel is in broadcast mode inspection mode is active; broadcast of alarms is disabled Programming buttons [P1] Special configuration For more information, refer to section 7.3 Special configurations on Page 33. Select alarm zone 1 Log on a radio device onto the SRC 3000 radio fire warning panel. For more information, refer to section 5.2 on Page 19. [P2] Select alarm zone 2 Log on a radio device onto the SRC 3000 radio fire warning panel. For more information, refer to section 5.2 on Page 19. [P3] [P4] [P5] Relay assignment For more information, refer to section "7.1 Configuration of the SRC 3000 panel" on Page 28. Set PIN code For more information, refer to section "5.1.2 Editing the PIN code" on Page 19. Inspection mode For more information, refer to section "10.2.1 Activating/deactivating the service mode" on Page 39. Select alarm zone 3 Log on a radio device onto the SRC 3000 radio fire warning panel. For more information, refer to section 5.2 on Page 19. Select alarm zone 4 Log on a radio device onto the SRC 3000 radio fire warning panel. For more information, refer to section 5.2 on Page 19. Select alarm zone 5 Log on a radio device onto the SRC 3000 radio fire warning panel. For more information, refer to section 5.2 on Page 19. [P6] Select alarm zone 6 Log on a repeater onto the SRC 3000 radio fire warning panel. For more information, refer to section 5.3.1 on Page 22. or Log on a radio device onto the SRC 3000 radio fire warning panel. For more information, refer to section 5.2 on Page 19. Function keys [F1] [F2] [F3] [F4] Acknowledgement and panel reset, for events and alarms Delete radio devices For more information, refer to section 9.1 on Page 36. Silence all radio devices temporarily for 3 minutes. After that time has elapsed, they will become activate again. For more information, refer to section 9.1 on Page 36. Radio device status; Scroll function For more information, refer to section 9.1 on Page 36. Confirmation (enter) function for entries and programming For more information, refer to section 9.1 on Page 36. Version 1.2 11

Product Information 3.7 Radio module 433 bidirectional 3.7.1 Function The radio module for use in smoke detectors is used for transmitting alarms and faults to the SRC 3000 radio fire warning panel. When a radio device goes into alarm the signal is transmitted to the SRC 3000 panel, which broadcasts the alarm condition to other radio devices and triggers the acoustic alarm in the radio smoke detector. Data exchange is bidirectional (broadcast alarm function). The acoustic signals for received alarms of individual radio devices with radio module can also be deactivated separately at the radio module. For more information, refer to section: "5.2.2 Deactivation of acoustic signalling on a smoke detector fitted with a radio module" on Page 21. The following functions are available: Transmission of radio integrity telegrams to the SRC 3000 radio fire warning panel to monitor the function. Display the signal strength from the radio smoke detector during the log on process to the SRC 3000 radio fire warning panel. Transmission of faults from radio smoke detectors and battery replacement signals to the SRC 3000 radio fire warning panel after a plausibility check. Individually adjustable acoustic signals indicating receipt of alarms. 3.7.2 Control and indicating elements The radio module is programmed using the programming button and the LED. For more information, refer to section "5 Logging on radio devices" on Page 18, section "5.2 Logging on a smoke detector fitted with a radio module onto SRC 3000 panel" on Page 19. 1 Programming button 2 LED 3.8 Radio Repeater SRC 3000 3.8.1 Function The radio repeater extends the radio link between the SRC 3000 radio fire warning panel and the radio devices with the 433 bidirectional radio module. This ensures a reliable transmission of radio signals even in the case of unfavourable radio conditions, e.g. steel reinforcement in concrete ceilings or walls. A maximum of three radio repeaters can be used, with each SRC 3000 radio fire warning panel. Up to ten radio devices with radio modules can be logged onto one radio repeater. The Cascading of radio repeaters is not possible. The radio repeater is designed to be wall mounted and requires an external 12V DC power supply. Version 1.2 12

Product Information The following functions are available: Transmission of radio device signals (alarms, faults, status messages) to the SCR 3000 radio fire warning panel. Transmission of the radio integrity telegrams for monitoring of function. Display of the signal strength of radio repeater onto the display of the SRC 3000 radio fire warning panel during commissioning. Power supply via an external 12 V power supply with battery back-up to provide an emergency power supply plus 1 x 9 V alkaline battery type IEC 6LR61. Checking of signal strength of radio devices when they are logged on. If the signal strength of a radio device at the radio repeater is too low, logging on of the radio device will not be possible. Warning! Have non-functioning radio repeaters checked by the manufacturer! Do not carry out any unauthorized modifications of the radio repeater! The insulation of the antenna must not be damaged! The antenna may be live when the unit is connected to the power supply unit! 3.8.2 Control and indicating elements 1 Status LED s of radio fire warning panel - Operation - Prog (Programming) - Fault 2 Programming buttons - Reset - Prog (Programming) For more information on installation, refer to: - "4.3 Installation of the radio repeater" on Page 17 on programming, refer to: - "5.3 Procedure if radio repeater is used" on Page 22 Version 1.2 13

Product Information - "5.3.3 Logging on radio devices fitted with a radio module onto the radio repeater" on Page 23 - "5.3.1 Logging on the repeater to the SRC 3000 panel" on Page 22 Buttons [Prog] [Reset] Function Start programming Delete radio device; start connection test LED LED signal Function LED "Operation" green On Flashing Normal operation Mains failure (emergency power supply) LED "Prog" red Fast flashing/ on Programming procedure LED "Fault" yellow flashing low battery LED "Prog" + LED "Fault" red + yellow on Double programming of a radio device All radio modules apart from the reset module can be logged onto the radio repeater. The reset module needs to be logged directly onto the SRC 3000 radio fire warning panel. 3.9 Radio device The following radio devices can be used with the SRC 3000 panel. smoke detector HDv 3000 O All designs from the HDv 3000 O range can be used. art. 30458 underside top radio module for smoke detector FM SRC 3000 art. 32488 radio module for heat detector FMT SRC 3000 art. 32489 Radio push button detector FHFM SRC 3000 art. 32490 Radio manual call point FMCP SRC 3000 art. 32491 Radio sounder / beacon Midi FABM SRC 3000 art. 32492 Version 1.2 14

Product Information Radio Repeater FRP SRC 3000 art. 32493 Radio input module FIB SRC 3000 art. 32494 Radio reset module FRM SRC 3000 Heat detector HD 3000 T art. 32503 art. 31957 Version 1.2 15

Installation 4 Installation 4.1 Installation of the radio fire warning panel SRC 3000 Warning! Risk of electric shock. The electrical installation (power supply 230 V AC) may only be performed by an authorized electrician! Before installation and connection of the SRC 3000 radio fire warning panel, disconnect 230 V power supply and take appropriate measures to prevent unintentional reconnection. For connecting the radio fire warning panel SRC 3000 to a power supply, please use VDEapproved connecting terminals. The isolation device and the additional short-circuit protection must be according to EN 60950 (VDE 0805) or compliant with equivalent local standards for alarm panel installations in buildings. Do not install the SRC 3000 radio fire warning panel in rooms which are too small and cramped. Otherwise there is the risk of faults caused by radio echo. 1 Open the battery compartment on the left side of the unit. Push the battery compartment cover in the direction of the arrow. 2 Take out the battery holder and insert the batteries to their corresponding positions. Observing correct polarity. 3 Connect the battery holder to the battery clip. 4 Put the battery holder with the batteries back into the battery compartment. 5 Close the battery compartment cover. 6 Connect the mains cable from the SRC 3000 panel to the 230 V power supply (N-wire blue, L1-wire black) to the corresponding connection terminals. 7 Mount the SRC 3000 panel at its intended position. Please use the supplied screws and raw plugs for mounting the unit. First fix the lower and then the upper screw. 8 Now, switch on 230 V power supply. The SRC 3000 panel will perform a self-test. After that, the green "Power" LED should be on. The SRC 3000 radio fire warning panel is ready for operation. After inserting the batteries, you will have to wait for at least 10 seconds before starting the login or commissioning procedure. Version 1.2 16

Installation 4.2 Installation of the 433 bidirectional radio module 1 Turn the smoke detector anticlockwise and take it off the base. 2 Hold the smoke detector so that the battery compartment is facing upwards. 3 Take out the 9V battery. 4 Place the radio module into the corresponding slot. On the left hand side, directly underneath the battery compartment, you will find six horizontal supporting points. These points are numbered from left to right (1; 2; 3; 4; 5; 6). The radio module only has five connecting pins. Ensure that pins 2 through 6 are connected when inserting the radio module. Point 1 (left point) remains free. Ensure that the cut-outs fit in the battery holder to avoid the bending of contacts. Warning! Earth yourself before handling the radio modules to avoid damage caused by electro static discharge. 5 Connect the 9V battery to the battery connector and insert the battery into its holder. 6 Replace the smoke detector with the radio module back into its base and lock it by turning it gently clockwise. 7 Repeat this procedure for all the required smoke detectors. 4.3 Installation of the radio repeater Do not install the radio repeater in rooms which are too small and cramped. Otherwise there is the risk of faults caused by radio echo. 1 Open the battery compartment on the back of the unit. Push the battery compartment cover in the direction of the arrow. 2 Connect the 9V battery to the battery clip and put the battery in the battery compartment. 3 Close the battery compartment cover. 4 Take the wall fixture from the rear of the unit and mount it at the place of installation. Please use the supplied screws and plugs for mounting the unit. 5 Insert the radio repeater (from below) to the wall fixture and push it down until it locks in. 6 Connect the EXTERNAL 12V DC power supply unit to the radio repeater. The radio repeater will perform a self-test. After that, the green "Operation" LED will be on. The radio repeater is then ready for operation. Version 1.2 17

Logging on radio devices 5 Logging on radio devices To ensure trouble-free operation of the SRC 3000 radio fire warning panel and the corresponding radio devices fitted with a radio module, logging on the radio devices should be performed by two technicians who communicate via mobile phones or radio equipment, etc. One technician will program the SRC 3000 panel; the other technician will program the radio devices at their place of installation. Up to 100 radio devices can be logged onto each SRC 3000 panel in six different zones (Zone 1 to Zone 6). The SRC 3000 panel and the radio repeater should be at their respective places of installation while being programmed. This way, it is possible to assess the quality of the radio signal strength indicated on the SRC 3000 panel. Ensure that all doors within the radio range are closed during the programming procedure. Otherwise, fault messages may occur during the radio integrity cycle request from the SRC 3000 panel. Select the individual zones by pressing the corresponding programming button [P1] to [P6] briefly (press and release). 5.1 Control authorization via PIN code Configuration and use of the SRC 3000 radio fire warning panel as well as resetting and deletion of radio devices are PIN code protected. By assigning a PIN code, it is ensured that only authorized personnel can edit or delete the programming and settings of the SRC 3000 radio fire warning panel. In the case of certain functions, the PIN code will be requested several times. Once entered, the PIN will be active for 10 minutes. During this time, you can change the settings of the SRC 3000 radio fire warning panel without having to re-enter the PIN code. The default PIN code is 1111. It is recommended that the default settings should be changed. Version 1.2 18

Logging on radio devices 5.1.1 Entering the PIN code Enter the PIN code as follows: For example, the default setting is 1111. 1 1 1 1 When you press a programming button on the SRC 3000 panel, the following menu will be displayed _. 1 Press function key [F3] twice. 1 will be displayed. 2 Press function key [F4] once to confirm the value and move the cursor to the left by one position. _ 1 will be displayed. 3 Repeat the steps described in items 1 and 2 in the same order until the display reads 1 1 1 1. 4 Then, press the function key [F4] to confirm the PIN code. The display will clear. 5.1.2 Editing the PIN code 1 2 3 4 1 Press and hold the programming button [P4]. 2 Press the function key [F3] and set the required value. 3 Press function key [F4] once to confirm the value and move the cursor to the left by one position. 4 Repeat the steps described in items 2 and 3 in the same order until the required PIN code is displayed. For example, default setting 1 2 3 4. 5 Then, press function key [F4] to confirm the PIN code. The display will then clear. 6 Release the programming button [P4]. The edited PIN code is saved. 5.2 Logging on a smoke detector fitted with a radio module onto SRC 3000 panel When logging on radio devices, you must be at least 3 metres away from the SRC 3000 panel. To log on a smoke detector with radio module, proceed as follows. In the following example, the detector is logged onto zone 1. 1 0 0 1 On the SRC 3000 panel, press the programming button of the required alarm zone briefly (press and release) ([P1] for zone in this example). The LED from the zone will start fast flashing (LED "Zone 1", in this example). The first free address is shown on the display of the panel. The display indicates as follows: 1 represents zone 1 00 represents the first free address Version 1.2 19

Logging on radio devices Address 00 = 1st logged on radio device Address 01 = 2nd logged on radio device Addresses from 00 to 99 are available. Independent from the selected zone, the next free address will be assigned when logging on radio devices to the SRC 3000 panel. This is done irrespective of the type of radio device (radio smoke detector, radio repeater, etc.). The following logging on steps should be carried out in sequence. 2 Press and release the programming button on the radio module of the smoke detector to be logged on. The LED of the radio module will start fast flashing. 3 Now, press the test button on the front of the smoke detector for approx. 5 seconds. If the signal of the radio module is recognized by the SRC 3000 panel, the LED on the radio module will stay on. The LED will then turned off again after about1 minute. 4 Follow the logging on procedure for the radio fire warning SRC 3000 panel. If the programming is successful, the LED "Zone 1" will stay on until the programme button is pressed again or after 20 minutes The RF field strength of the received signal will be displayed. Scale: 000 to 010 5 Note the displayed value from the detector, write this down and store this information near the SRC 3000 radio fire warning panel. Example Address Zone RF field strength Place ID 00 1 007 corridor, basement 01 1 005 Office left, ground floor For values 004, please use a radio repeater to amplify the signal. After approx. 20 minutes, the LED "Zone 1" and the display will go out on the SRC 3000 panel. The display and the LED "Zone 1" can also be turned off by pressing a programming once button again. The smoke detector with radio module is now logged on. To log on more smoke detectors fitted with radio modules, proceed as described in section "5.2 Logging on a smoke detector fitted with a radio module onto SRC 3000 panel" on Page 19. Double addressing and re-checking the radio signal strength If you try to log on a radio device which has already been logged on this will be indicated on the panel with the LED Device, also the display will show the current zone and device address. Additionally by pressing the button [F3] the current signal strength from that device will be viewed. By carrying out the above, it is possible to re-check the signal strength of a radio device. Version 1.2 20

Logging on radio devices 5.2.1 Minimising errors during the login process In the case of errors during the logging on of smoke detectors, proceed as follows: Delete the relevant smoke detector with radio module from the SRC 3000 panel as described in section "6.1 Deleting radio device directly from the SRC 3000 panel" on page 25. Then, reset the smoke detector with radio module according to section "6.4.1 Performing a reset on smoke detector fitted with a radio module" on Page 27. If necessary, log on the smoke detector again. For more information, refer to section "5.2 Logging on a smoke detector fitted with a radio module onto SRC 3000 panel" on Page 19. 5.2.2 Deactivation of acoustic signalling on a smoke detector fitted with a radio module If you want to deactivate the acoustic signalling of received alarms on a smoke detector fitted with a radio module, proceed as follows: 1 Press the test button of the smoke detector for 6 seconds to trigger a test alarm. Wait until all smoke detectors have activated their sounder. 2 Now, press the programming button on the radio module from the smoke detector to be silenced for approx. 4 seconds until the LED from the radio module and the sounder from the smoke detector has silenced. 3 Acknowledge the event: Press the function key [F1] on the SRC 3000 panel. The test alarm will then silence approx. 20 seconds after the event has been acknowledged. For more information, refer to section "9.2.2 Acknowledging alarm/fault messages" on Page 38. Even if receiving alarms signals has been deactivated, the radio device will still sound local alarms if that device is activated.. 5.2.3 Re-activation of acoustic signalling on smoke detectors fitted with a radio module If you want to re-activate the acoustic signalling of received alarms on a radio device, proceed as follows: Reset the smoke detector with radio module fitted. For more information, refer to section "6.4.1 Performing a reset on smoke detector fitted with a radio module" on Page 27. Delete the device from panel. Re-log the smoke detector onto SRC 3000 panel again. For more information, refer to section "5.2 Logging on a smoke detector fitted with a radio module onto SRC 3000 panel" on Page 19. Version 1.2 21

Logging on radio devices 5.3 Procedure if radio repeater is used If the radio strength is 004, please use a radio repeater to amplify the signal. It is important to note that the repeater needs to be logged onto the panel first (Zone 6). Any device which needs to be logged onto the radio repeater must first of all be logged onto the SRC 3000 panel. Once the devices have been logged on, only then can you log them onto the radio repeater. Do not install the radio repeater in rooms which are too small and cramped. Otherwise there is the risk of faults occurring due to radio echo. All radio modules apart from the radio reset module can be logged onto the radio repeater. The radio reset module needs to be logged directly onto the SRC 3000 panel. If radio repeaters are used, you must proceed as follows: Log the radio repeater onto the SRC 3000 panel (zone 6). Check signal between radio repeater and the SRC 3000 panel and reposition it, if necessary. For more information, refer to section "8.1.2 Testing the communication signal to the radio repeater" on Page 35. Log on any relevant radio devices fitted with radio modules onto SRC 3000 panel. For more information, refer to section "5.2 Logging on a smoke detector fitted with a radio module onto SRC 3000 panel" on Page 19. Log the relevant radio devices onto radio repeater. 5.3.1 Logging on the repeater to the SRC 3000 panel Now, log the radio repeater onto SRC 3000 panel. Radio repeaters can only be logged onto Zone 6 of the SRC 3000 panel. The radio repeater and SRC 3000 panel should be at their respective places of installation while being programmed. This way, it is possible to assess the quality of the radio link based on the signal strengths indicated on the SRC 3000 panel. When requested, enter the PIN code. For more information, refer to section "5.1.1 Entering the PIN code" on Page 19. 1 Press and release the programming button [P6] on the SRC 3000 panel. The "P6" LED will be fast flashing. The first free address will be displayed on the SRC 3000 panel. 6 1 8 On the display, for example: 6 representing zone 6 18 representing the next free address for the radio repeater Independently from the selected Zone, the next free address will be assigned when logging on radio devices to the SRC 3000 panel. This is done irrespective of the type of radio device (radio smoke detector, radio repeater, etc.). Version 1.2 22

Logging on radio devices 2 Press and hold the [Prog] button on the radio repeater. The "Prog" LED and the "Operation" LED will light up. The "Operation" LED will be turned off after 5 seconds. The "Prog" LED will be turned off after successful login. The "Operation" LED will again light up and stay on. 3 Release the [Prog] button on the radio repeater. The SRC 3000 panel will now display the assigned address and the signal strength of the radio repeater. The "Zone 6" LED will light up for 20 minuets or until the P6 button is again pressed.. 4 Check the signal between the radio repeater and the SRC 3000 panel. For more information, refer to section "8.1.2 Testing the communication signal to the radio repeaters signal strength" on Page 35. 5 Make any required adjustments; if necessary (relocate hardware, etc.). 6 Come out of the programming mode by pressing the button [P6] on the SRC 3000 panel briefly. 5.3.2 Logging on smoke detectors fitted with radio modules onto the SRC 3000 panel The radio devices logged onto the radio repeater must also be also be logged on to the SRC 3000 panel. To log on the radio device, proceed as described in section "5.2 Logging on a smoke detector fitted with a radio module onto SRC 3000 panel" on Page 19. 5.3.3 Logging on radio devices fitted with a radio module onto the radio repeater During logging on of radio devices, the radio repeater will check the strength of the received signal. If the signal strength is not above 3, the logging on of that device will not be accepted. However, the radio repeater will remain in the programming mode. If necessary, relocate the unit or device. When logging on radio devices, stay at least 3 metres away from the SRC 3000 panel. Logging the relevant smoke detector fitted with a radio module onto the radio repeater. 1 Press the [Prog] button on the radio repeater briefly. The "Prog" LED will start fast flashing. 2 Press briefly the programming key on the radio module of the relevant smoke detector. The LED on the radio module will also start fast flashing. 3 Now, press and hold the test button on the front of the smoke detector down for approx. 5 seconds. If the signal from the radio module is recognized on the radio repeater, the LED on the radio module will stay on and turn off automatically after 1 minute. 4 Press the [Reset] button on the repeater to finish the programming procedure. Version 1.2 23

Logging on radio devices Double addressing If a radio device has already been logged on to the repeater, the second time you try to log the device on will result in the "Fault" LED being on along with the "Prog" LED. The LED on the module will also flash indicating a double address. If required, you can delete the device individually as described in section "6.2.1. See: deleting" on Page 26. Log on the radio device again as described in section "5.3.3 Logging on radio devices fitted with a radio module onto the radio repeater" on Page 23. Version 1.2 24

Deleting radio devices 6 Deleting radio devices 6.1 Deleting radio device directly from the SRC 3000 radio fire warning panel If you want to delete radio module from the SRC 3000 panel, proceed as follows: 1 0 0 1 0 4 1 On the SRC 3000 panel, press the function key [F3] briefly. When requested, enter the PIN code. For more information, refer to section "5.1.1 Entering the PIN code" on Page 19. 1 _ 0 0 will be displayed 2 Press function button [F3] several times (scroll) until the address of the smoke detector to be deleted is displayed. Example: 1 _ 0 4 3 Press the programming button [F1] and keep it pressed. After approx. 4 seconds, the corresponding LED "Zone 1" "Zone 6" and the displayed address will be flashing. After approx. 10 seconds, the corresponding LED "Zone 1" "Zone 6" will stay on. The following prompt will be displayed. 4 When requested, enter the PIN code. After entering the PIN code, you have deleted the smoke detector from the SRC 3000 panel. If you want to abort the deletion of the detector, enter a wrong PIN code. Now, carry out a reset on the radio module of the smoke detector. For more information, refer to section "6.4.1 Performing a reset on smoke detector fitted with a radio module" on Page 27. 6.2 Deleting radio devices operated via a radio repeater If you want to delete a smoke detector fitted with a radio module which is being used to communicate to the SRC 3000 panel via a radio repeater, proceed as follows: Delete the smoke detector from the SRC 3000 panel. For more information, refer to section "6.1 Deleting radio device directly from the SRC 3000 radio fire warning panel" on Page 25. Delete the radio device from the radio repeater. For more information, refer to section "6.2.1 Deleting a radio module from the radio repeater" on Page 26. Then, perform a reset on the radio module of the smoke detector. For more information, refer to section "6.4.1 Performing a reset on smoke detector fitted with a radio module" on Page 27. Version 1.2 25

Deleting radio devices 6.2.1 Deleting a radio module from the radio repeater Repeat the login procedure for a smoke detector to a radio repeater. 1 Press the [Prog] button on the radio repeater briefly. The "Prog" LED will be fast flashing. 2 Press the programming key on the radio module of the relevant smoke detector. The LED on the radio module will also start fast flashing. 3 Now, press the test button on the front of the smoke detector, the LED on the radio module will continue to flash (because the module has already been logged onto the repeater.) Since the smoke detector has already been logged onto the radio repeater, the "Fault" LED will be on along with the Prog LED, on the repeater.. 4 Press the [Reset] button on the repeater within 5 seconds. The smoke detector fitted with a radio module is now deleted from the radio repeater. 6.3 Deleting a radio repeater from the SCR 3000 fire warning panel 1 0 0 6 0 4 1 Press the function key [F3] on the SRC 3000 panel briefly. The following prompt will be displayed: 1 _ 0 0 2 Press function button [F3] several times until the address of the radio repeater to be deleted is displayed. Example: 6 _ 0 4 3 Then, press and hold the function key [F1] until the LED "Zone 6" and the address of the repeater are flashing. 4 Keep the function key [F1] pressed until the LED "Zone 6" and the address stop flashing on the display. 5 When requested, enter the PIN code. For more information, refer to section "5.1.1 Entering the PIN code" on Page 19. By entering the PIN code, you have successfully deleted the radio repeater from the SRC 3000 panel. Version 1.2 26

Deleting radio devices 6.4 Reset 6.4.1 Performing a reset on smoke detector fitted with a radio module In order to delete a smoke detector from the SRC 3000 panel, follow the steps bellow. 1 Press and hold the programming key on the radio module of the relevant smoke detector for approx. 4 seconds. The LED on the radio module will start flashing slowly. 2 Release the programming key and then repress and hold the programming button (for up to 10 seconds) until the LED on the radio module stays on. The reset is complete. The LED will be turned its self off again after about 1 minute. 6.4.2 Performing a general reset on the radio repeater A general reset on the radio repeater will remove all saved radio devices which have been logged onto the radio repeater. 1 Press and release the [Prog] button. The "Prog" LED will start fast flashing. 2 Press and hold the [Reset] button until all LED s light up. Keep the reset button pressed until the "Prog" and "Fault" LED s go out. Only the "Operation" LED will be on. You can then release the reset button. The general reset is now complete. 6.4.3 Performing a general reset on the SRC 3000 panel A general reset on the panel SRC 3000 panel will delete all saved radio devices and all information from the panel. 1 Press and hold the function keys [F1] and [F3] simultaneously, after 5 seconds all Zones LED s will start flashing for a few seconds and then stay on. 2 When requested, enter the PIN code. For more information, refer to section "5.1.1 Entering the PIN code" on Page 19. Enter the PIN code to complete the general reset. All of the panel settings will then be reset to the factory default settings. If you want to abort the reset procedure of the panel, enter a wrong PIN code... Version 1.2 27

Configuration 7 Configuration 7.1 Configuration of the SRC 3000 panel 7.1.1 Assigning relays to zones 1 Press and hold the programming button [P3] and keep it pressed. 2 If requested, enter the PIN code. For more information, refer to section "5.1.1 Entering the PIN code" on Page 19. 1 (2,3,4,5,6) Event 1 (2,3,4,0) Relay The following prompt will be displayed: Event: 1 _ refers to zone 1 Relay: 1 refers to relay 1 now; you can assign a relay to zone 1. 3 Press function key [F3] and set the required relay. You can choose among entries 0 to 4. 1 1 (2,3,4,0) Meaning of entry Entry 0 no relay selected Entry 1 Relay 1 Entry 2 Relay 2 Entry 3 Relay 3 Entry 4 Relay 4 4 By pressing the function key [F4], you can also choose other alarm zones (Zone 1 to Zone 6) and assign relays to the corresponding zones as described in Item 3. 5 Release the programming button [P3]. All alarms from alarm zone 1 will address the programmed relay. 7.1.2 Programming a relay for a "Radio Device Fault" 1 1 (2,3,4,0) Event Relay 7 1 (2,3,4,0) 1 Press the programming button [P3] and keep it pressed. 2 If requested, enter the PIN code. For more information, refer to section "5.1.1 Entering the PIN code" on Page 19. 1 1 will be displayed. Event: 1 _ refers to Event 1. Relay: 1 refers to Relay 1 3 Press function key [F4] until 7 _ is displayed. 4 Press function key [F3] and set the required relay. You can choose among entries 0 to 4. Version 1.2 28

Configuration Meaning of entry Entry 0 no relay selected Entry 1 Relay 1 Entry 2 Relay 2 Entry 3 Relay 3 Entry 4 Relay 4 5 Release the programming button [P3]. All radio device fault messages are now assigned to one relay. 7.1.3 Programming a relay a "SRC 3000 panel fault" 1 1 (2,3,4,0) Event Relay 1 Press the programming button [P3] and keep it pressed. 2 If requested, enter the PIN code. For more information, refer to section "5.1.1 Entering the PIN code" on Page 19. The following prompt will be displayed: 1 1. Event: 1 _ refers to Event 1. Relay: 1 refers to Relay 1 3 Press function key [F4] until 8 _ is displayed. 4 Press function key [F3] and set the required relay. You can choose among entries 0 to 4. 8 1 (2,3,4,0) Meaning of entry Entry 0 no relay selected Entry 1 Relay 1 Entry 2 Relay 2 Entry 3 Relay 3 Entry 4 Relay 4 5 Release the programming button [P3]. All SRC 3000 panel faults are now assigned to one relay. 7.1.4 Programming relays for a common alarm 1 1 (2,3,4,0) Event Relay 1 Press the programming button [P3] and keep it pressed. 2 If requested, enter the PIN code. For more information, refer to section "5.1.1 Entering the PIN code" on Page 19. 1 1 will be displayed. Event: 1 _ refers to Event 1. Relay: 1 refers to Relay 1 3 Press function key [F4] until 11 _ is displayed. 4 Press function key [F3] and set the required relay. You can choose among entries 0 to 4. 11 1 (2,3,4,0) Version 1.2 29

Configuration Meaning of entry Entry 0 no relay selected Entry 1 Relay 1 Entry 2 Relay 2 Entry 3 Relay 3 Entry 4 Relay 4 5 Release the programming button [P3]. Common alarm is now assigned to a relay. 7.1.5 Programming relays for a common fault 1 1 (2,3,4,0) Event Relay 12 1 (2,3,4,0) 1 Press the programming button [P3] and keep it pressed. 2 If requested, enter the PIN code. For more information, refer to section "5.1.1 Entering the PIN code" on Page 19. 1 1 will be displayed. Event: 1 _ refers to Event 1. Relay: 1 refers to Relay 1 3 Press function key [F4] until 12 _ is displayed. 4 Press function key [F3] and set the required relay. You can choose among entries 0 to 4. Meaning of entry Entry 0 no relay selected Entry 1 Relay 1 Entry 2 Relay 2 Entry 3 Relay 3 Entry 4 Relay 4 5 Release the programming button [P3]. Common fault is now assigned to a relay. 7.1.6 Programming the relay outputs from steady to pulsed This operation can programme relays from steady (contacts are held) to pulsed (contacts are pulse for 5 seconds). This is a general setting for all 4 relays. 1 1 (2,3,4,0) Event Value 1 Press the programming button [P3] and keep it pressed. 2 If requested, enter the PIN code. For more information, refer to section "5.1.1 Entering the PIN code" on Page 19. 1 1 will be displayed. Event: 1 _ refers to Event 1. Value: 1 refers to Value 1 3 Press function key [F4] until 13 _ is displayed. Version 1.2 30

Configuration 13 0 (1) 4 Press function key [F3] and set the required value. You can select either a 0 or a 1. Meaning of entry 0 = Relays steady 1 = Relays pulsed 5 Release the programming button [P3]. Steady or pulsed relays have now been set. 7.1.7 Relay configuration This setting enables the relays to be changed from normally open N/O to normally closed N/C contacts. If the relays are to be used for faults it is recommended to use N/O contacts. Please note that these settings affect current draw and therefore the battery backup times... 1 1 (2,3,4,0) Event Value 1 Press the programming button [P3] and keep it pressed. 2 If requested, enter the PIN code. For more information, refer to section "5.1.1 Entering the PIN code" on Page 19. 1 1 will be displayed. Event: 1 _ refers to Event 1 Value: 1 refers to Value 1 3 Press function key [F4] until 14 _ to 17 _ is displayed (setting of relays 1 to 4). 4 Press function key [F3] and set the required value. You can choose among entries 0 or 1. 14 (15,16,17) 0 (1) Meaning of entry 0 Relay is set to normally closed N/C. 1 Relay is set to normally open N/O 5 Release the programming button [P3]. The relays have now been configured either to N/O and N/C. Version 1.2 31

Configuration 7.1.8 Programming overview table for sections 7.1.1 to 7.1.7 Programming button Function Notes [P3] Relay assignment Four relays can be configured to react to different events. Default setting No. Event Display 1 Alarm zone 1 (section 7.1.1) 1 1 2 Alarm zone 2 (section 7.1.1) 2 2 3 Alarm zone 3 (section 7.1.1) 3 2 4 Alarm zone 4 (section 7.1.1) 4 3 5 Alarm zone 5 (section 7.1.1) 5 3 6 Alarm zone 6 (section 7.1.1) 6 4 7 Radio device fault (section 7.1.2) 7 0 8 SRC 3000 panel fault (section 7.1.3) 8 0 11 Common alarm (section 7.1.4) 1 1 _ 0 12 Common fault (section 7.1.5) 1 2 _ 0 13 Operation mode: 0-steady,1-pulsed (sections 7.1.6) 1 3 _ 0 14 Relay 1 Normally open N/0 0 / Normally closed N/C 1 (section 7.1.7) 15 Relay 2 Normally open N/O 0 / Normally closed N/C 1 (section 7.1.7) 16 Relay 3 Normally open N/O 0 / Normally closed N/C 1 (section 7.1.7) 17 Relay 4 Normally open N/O 0 / Normally closed N/C 1 (section 7.1.7) 1 4 _ 0 1 5 _ 0 1 6 _ 0 1 7 _ 0 7.2 PIN configuration for the SUB-D connector PIN configuration for the Sub-D socket PIN Signal Relay Contact PIN Signal Relay Contact 1 R 1/1 1 15 R 3/1 3 6 R 1/2 1 10 R 3/2 3 11 R 1/3 1 5 R 3/3 3 4 R 2/1 2 12 R 4/1 4 3 R 2/2 2 13 R 4/2 4 2 R 2/3 2 14 R 4/3 4 Version 1.2 32

Configuration 7.3 Special configurations 7.3.1 Parameter 1 Fault message "Radio" indicates a radio fault with the communication between the panel and a module. This fault can be set to non latching (resets automatically as soon as the radio communication is re-established). (Value 1) or latching (value 0 = default setting) meaning the panel needs to be reset manually via the reset button. 7.3.2 Parameter 2 For all faults received by the SRC 3000 panel, such device, battery, radio, or alarms, a tone indication will sound (approx. 45 seconds) on the SRC 3000 panel until the event is acknowledged by pressing the reset button. The default, value 0 (ON) is set. When set to value 1 (OFF) no tone will be sounded. 7.3.3 Parameter 3 With this setting you have the option to enable/disable the PIN code. Meaning when the value 0 (default) is set, any panel actions require the PIN to be entered. When the value is set to 1, the PIN is not required. 7.3.4 Parameter 4 Here, you can activate/deactivate the displaying of radio fault messages. All other faults will be displayed. By default, the value is set to 0 (ON) meaning radio faults will be displayed. 1 0 (1) Parameter 1 (2,3,4) Value 0 (1) Programming the parameters 1 Press and hold the programming button [P1]. 2 If requested, enter the PIN code. For more information, refer to section "5.1.1 Entering the PIN code" on Page 19. 1 1 will be displayed. Parameter: 1 _ Value: 0 3 Press function key [F4] until the required parameter is displayed. 4 Press function key [F3] and set the required value. You can switch between 0 and 1. No. Parameter Set values 1 Automatic resetting of radio fault messages 2 Faults / Events reminder sound OFF 0 ON 1 ON 0 OFF 1 3 PIN requirement ON 0 OFF 1 4 Displaying of radio fault messages ON 0 OFF 1 5 Release the programming button [P1]. The corresponding parameters are set. Version 1.2 33

Commissioning 8 Commissioning 8.1 Functionality tests Check the configuration of your system using the function test described below. Firstly, select the radio devices which are the furthest in distance away from the SRC 3000 panel or any devices which you think could or might incur radio problems.. If any device has no radio communication with the SRC 3000 panel, or the radio signal is below 4 we would recommend using a radio repeater. NOTE: Cascading of radio repeaters is not possible. Repeat the function tests at least once a year during service and maintenance of the system. If the following function tests are carried out after a service/maintenance check, that the inspection/maintenance mode has been deactivated before leaving site. For more information, refer to section "10.2.1 Activating/deactivating the service mode" on Page 39. 8.1.1 Alarm testing 1 Press down the test button on the detector. The alarm will be displayed on the SRC 3000 panel immediately. Further alarm testing steps: Within 20 seconds, the SRC 3000 panel, if it has received the alarm signal, activates the sounders of all the smoke detectors which are fitted with radio modules and are logged onto the SRC 3000 panel. If the SRC 3000 panel needs to transmit via repeaters, the smoke detectors logged onto the repeaters will have the following delays: One radio repeater fitted means all devices logged on will have an additional 20 seconds delay Two radio repeaters fitted means all devices logged on will have an additional 40 seconds delay Three radio repeaters fitted means all devices logged on will have an additional 60 seconds delay Acknowledge the event on the SRC 3000 panel: 1 Press function key [F1]. 2 If requested, enter the PIN code. For more information, refer to section "5.1.1 Entering the PIN code" on Page 19. The alarm test will go out after 20 seconds. If the radio communication between the SRC 3000 panel and the radio modules does respond correctly, the alarm broadcast to the radio devices will be stop automatically after 20 minutes. Version 1.2 34

Commissioning 8.1.2 Testing the communication signal to the radio repeater Testing the communication between the repeater and the SRC 3000 panel. 1 Press button [Reset] on the radio repeater until the "Operation" LED goes out and the "Prog" LED lights up. If the communication test was successful, the "Prog" LED will go out after a few seconds and the "Operation" LED will light up once again. If there is no radio communication between the radio repeater and the SRC 3000 panel, the "Fault" LED will light up on the repeater in addition to the "Prog" LED. In this case, the radio repeater must be relocated in the range of the SRC 3000 panel. This communication test should be carried out more then once even if the radio communications seem to be ok. The quicker the "Prog" LED switches over to "Operation", indicates better communication between the two. Version 1.2 35

Operation 9 Operation 9.1 Function keys The SRC 3000 panel is operated by pressing the function keys [F1] to [F4] or two of theses keys at the same time. Function keys Function Notes Alarm monitoring [F1] Acknowledging events Status messages or alarms can be acknowledged by pressing [F1] and entering the PIN code. The corresponding events will be reset. Deleting radio devices from the panel Select the address of the radio device on the display by scrolling through the list with [F3], then press [F1] until the alarm Zone LED and the address stop flashing then when requested enter the PIN code to confirm the procedure. Note: After deleting a radio device, perform a general reset on that radio module. [F2] Silencing of alarms If the alarm from a radio device is displayed, you can deactivate the sounder on the SRC 3000 panel as well as all active sounders from the radio devices temporarily for 3 minutes. The alarm will still be displayed. Additionally, the LED "sounders silenced will be on. If a new alarm is received within these 3 minutes, the sounders automatically reactivate. [F3] Detector status Using [F3], you can scroll through all the addresses of the devices logged onto the system. [F1] + [F3] [F1] + [F4] [F4] Restoring the panel back to its factory default settings Software version / serial number Press [F1] + [F3] simultaneously. After 5 seconds, the zone LED s will start flashing. Keep [F1] + [F3] pressed until all zone LED s stay on. Enter the PIN code to complete the procedure. All of the settings have now been reset to their default values. Note: This reset deletes all saved radio devices and all information on the SRC 3000 panel. Recommendation: This reset procedure should be carried out before commissioning the panel for the first time. Press [F1] + [F4] simultaneously until the software version appears on the display. After 5 seconds, the serial number will be displayed. This button is used for programming and configuration of the SRC 3000 panel. Used as an enter function for confirming entries (e.g. PIN code) and programming. Version 1.2 36

Operation 9.2 Alarms and faults 9.2.1 Signalling of alarms and faults Alarms from radio devices If an alarm is detected by a radio device for more than 5 seconds, the following process is activated: The radio module sends a signal to the SRC 3000 panel. The alarm is indicated by one of the 6 zone LED s, 1 to 6 is displayed along with the address of the activated device. Within 20 seconds, the radio SRC 3000 panel, if it receives the alarm signal, activates, the sounders, of the detectors which are logged onto the SRC 3000 panel. If the SRC 3000 panel needs to transmit via a radio repeater, the communication is delayed as follows: One radio repeater fitted means all devices logged on will have an additional 20 seconds delay Two radio repeaters fitted means all devices logged on will have an additional 40 seconds delay Three radio repeaters fitted means all devices logged on will have an additional 60 seconds delay Faults from radio devices On the SRC 3000 panel, faults from the radio devices are displayed in three different categories: Device The "Device" fault message indicates that the smoke measuring chamber from the detector is or has been contaminated. Recommendation: Replace the affected radio device. Display on the SRC 3000 panel LED LED colour Display Device Yellow Zone Address (radio device) Display on the radio device (e.g. radio smoke detector) LED LED colour Signal On the radio smoke detector Yellow LED flashes (intervals of one per minute) brief tone (intervals of one per minute) "Device" faults on the radio smoke detectors are characterized by alternant flashing of the LED on the front and the short signal tone (tone, flash, tone, flash,...). Battery The "Battery" fault message indicates that the batteries in the radio smoke detector are low. Recommendation: Replace the batteries. Version 1.2 37

Operation Display on the SRC 3000 panel LED LED colour Display Battery Yellow Zone (area, zone) Address (radio device) Display on the radio device (e.g. smoke detector) LED LED colour Signal On the radio smoke detector Yellow LED flashes (intervals of one per minute) brief tone (intervals of one per minute) "Battery" faults on the smoke detector are characterized by the LED flashing and the tone sounding at the same time. Radio The "Radio" fault message indicates that in the radio integrity check of six unsuccessful cycles (time between cycles = 4 hours), has been detected between the SRC 3000 panel and the displayed radio devices. Recommendation in the case of an existing system: Check the premises. Were any structural changes might have been made (new walls, doors or large furniture)? If necessary, use a radio repeater. In this case, the radio devices must be logged on again. Recommendation in the case of new systems: Use a radio repeater and/or relocate the radio device. Display on the SRC 3000 panel LED LED colour Display Radio Yellow Zone (area, zone) Address (radio device) If the SRC 3000 panel receives a communication signal again, the "Radio" fault will be reset automatically. The automatic reset function can however be deactivated. For more information, refer to section "7.3 Special configuration" on Page 33. 9.2.2 Acknowledging alarm/fault messages 1 Note the displayed address of the radio device. 2 If necessary, press function key [F2] to switch off the panel tone temporarily. After 3 minutes, or when a new alarm is received, it will be automatically reactivated. 3 Press function key [F1]. 4 When requested, enter the PIN code. For more information, refer to section "5.1.1 Entering the PIN code" on Page 19. The alarm/fault on the display of the SRC 3000 radio fire warning panel will go out. The SRC 3000 panel is now reset. The sounders of the radio devices (only in the case of alarm) will be reset within approx. 20 seconds. Version 1.2 38

Maintenance 10 Maintenance 10.1 Inspection and maintenance intervals To ensure the system is kept working and well maintained, regular inspections and tests must be carried out Type of tests to be carried out daily weekly monthly yearly as required Checks/maintenance Function test Test alarm Test of connection to radio repeater X X X 10.2 Maintenance/Service measures 10.2.1 Activating/deactivating the service mode With this service function, you are able test individual devices without triggering the whole system. In the inspection mode, alarms from a radio device are displayed on the SRC 3000 panel. Only the sounder from the tested device will sound, the signal is not forwarded onto other devices. 1 0 (1) Event Value 1 0 (1) 1 Press and hold the programming button [P5] and keep it pressed. 2 If requested, enter the PIN code. For more information, refer to section "5.1.1 Entering the PIN code" on Page 19. 1 0 will be displayed. Event: 1 _ refers to Event 1 (inspection mode) Value: 0 refers to Value 0 After 5 seconds, LED "Zone 5" will go out. On the display the inspection mode settings will appear. 3 Press function key [F3] and set the required value. You can choose among entries 0 or 1. Meaning of entry Entry 0 (default setting) Entry 1 Inspection mode disabled: LED "Inspection" off Inspection mode enabled: LED "Inspection" flashing 4 Release the programming button [P5]. Inspection mode is activated / deactivated. Version 1.2 39

Maintenance If the inspection mode is not disabled manually, it will be reset back to the default settings after 8 hours non activity. This time can be changed. For more information, refer to section "10.2.2 Automatic disablement of the inspection mode" on Page 40. 10.2.2 Automatic disablement of the inspection mode If the inspection mode is not disabled manually, it will be automatically after 8 hours (default setting) disabled. This period can be adjusted from between 1 to 24 hours. 1 0 (1) Event Value 2 8 (1-24) 1 Press and hold the programming button [P5] and keep it pressed. 2 If requested, enter the PIN code. For more information, refer to section "5.1.1 Entering the PIN code" on Page 19. 1 0 will be displayed. 3 Press function key [F4]. The following prompt will be displayed: 2 8 (1 to 24). Event: 2 _ refers to the parameter Value: 8 refers to the time in hours 4 Press the function key [F3] to set the required time in hours. 5 Release the programming button [P5]. The timeout for automatic disablement of the inspection mode is now set. 10.3 Cleaning Clean the housing of the SRC 3000 radio fire warning panel regularly using a slightly moist or antistatic cloth. Do not use any solvents. 10.4 Environmental disposal According to the "Directive on Batteries and waste of batteries and accumulators" each user is obliged to return discharged batteries and accumulators to the point of sale or to a designated collection point. Please return only fully discharged batteries. If you no longer require the use of the SRC 3000 panel, ask your local waste disposal provider for the correct disposal measures. The SRC 3000 panel must not be disposed of as normal waste. Version 1.2 40