TECHNICAL GUIDE STELLAR 2000 TM MODELS: H*DB012 THRU H*DB076 (1 Ø & 3 Ø) SPLIT-SYSTEM AIR CONDITIONERS A TG2Y (02/00) DESCRIPTION

Similar documents
SPLIT-SYSTEM CONDENSING UNITS. HRC Series TECHNICAL SPECIFICATIONS

TECHNICAL GUIDE STELLAR 2000 TM MODELS: E*FD018 THRU E*FD060 1 Ø E*FD036 THRU E*FD060 3 Ø SPLIT-SYSTEM HEAT PUMPS Rev A (0500)

SPLIT SYSTEM HEAT PUMPS "ERC" Series

SPLIT SYSTEM HEAT PUMPS 14 SEER

SPLIT-SYSTEM CONDENSING UNITS. "HRC" Series SEER. Models H*RC018 thru H*RC060 Nominal Capacity: 18 thru 60 MBH DESCRIPTION FEATURES

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE VARIABLE SPEED AIR HANDLERS DESCRIPTION FEATURES Rev. A (0105)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

Commercial High-Efficiency Condensing Units

2220 SE Ninth Avenue 2113 Delta Waters Road Portland OR Medford OR

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

R4H4. Product Specifications

INSTALLATION INSTRUCTION

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

R4H4. Product Specifications

September, Ductless Split Ceiling Cassette Ductless Mini-Split Models SSD, SSH and SCW

TECHNICAL GUIDE MODELS: MV MODULAR VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP DESCRIPTION FEATURES

Split System Cooling Product & Performance Data

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

TECHNICAL SPECIFICATIONS

N4A6. Product Specifications

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

AMERICAN STANDARD 14 MODELS 4A7B E

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

PAR5. Product Specifications

Split System Heat Pump Product Data

Split System Heat Pumps

SUBMITTAL DATA SHEET FEATURES. SPLIT-SYSTEM EVAPORATOR BLOWERS 7.5, 10, 15 & 20 TONS MODELS: NH-07 thru -20, 2-PIPE NJ-10 thru -20, 4-PIPE

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT

50TM COMBINATION HEATING/COOLING UNITS

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

N4H4. Product Specifications

Commercial High-Efficiency Condensing Units

PACKAGE AIR CONDITIONER

Product Data INDUSTRY LEADING FEATURES / BENEFITS. BH13NA SINGLE -STAGE HEAT PUMP WITH PURONr REFRIGERANT. Efficiency S S Reliability S

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

Product Data. 38CKD (60 Hz) 13 SEER Air Conditioner Sizes FEATURES AND BENEFITS AVAILABLE SIZES:

RSG16**S1M. Split System Air Conditioner 16 SEER

Nominal Capacity /2Ton 024 2Tons /2Tons 036 3Tons /2Tons 048 4Ton 060 5Ton

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

Split System Heat Pump Product Data

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Split System Cooling Product Data

Split System Heat Pump Product Data

STELLAR 2000 SINGLE PIECE AIR HANDLERS INSTALLATION INSTRUCTION Supersedes: N2Y (795) N2Y (1195)

50TM TFF COMBINATION HEATING/COOLING UNITS

Split System Cooling Product Data

Split System Heat Pump Product Data

E2 Series. Downflow, Upflow Electric Furnaces TECHNICAL SPECIFICATIONS. Features and Benefits

Split System Cooling Product Data

SPLIT SYSTEM COOLING 1½ 5 TON ALLEGIANCE 14 MODELS 4A7A C/30-060B American Standard Heating & Air Conditioning

TECHNICAL SPECIFICATIONS

Product Data INDUSTRY LEADING FEATURES / BENEFITS MODEL 126B PREFERRED SERIES AIR CONDITIONER WITH PURON REFRIGERANT 1 1/2 TO 5 NOMINAL TONS

Product Data PA13 AIR CONDITIONER 1 AND 3 PHASE 1-1/2-5 TONS ( ) FEATURES AND BENEFITS AVAILABLE SIZES:

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS

Split System Cooling Product Data

Product Data. Features/Benefits. GEMINI 38AKS Commercial Air-Cooled Split Systems 50/60 Hz. 25 to 40 Nominal Tons (82.8 to 127.

WJH4 Product Specifications

PAJ3. Product Specifications

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE

Split System Cooling Product Data

Split System Cooling Product Data

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Split System Cooling Units

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

RTG Ultron. Up to 16 SEER. Specification Sheet. Split System Heat Pump

TECHNICAL SPECIFICATIONS

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

SPLIT SYSTEM COOLING 1 1 / 2 5 TON MODELS 4A7A

13 SEER HEAT PUMPS. Featuring Earth-Friendly R-410A Refrigerant 13PJL SERIES. Features Coils constructed with copper tubing and enhanced aluminum

E3EH-xxx-H Series E3EB-xxx-H Series

Split System Cooling Product Data

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

Split System Heat Pump Product Data

Whirlpool Split System 13 SEER Air Conditioner W2C3. Features

TECHNICAL SPECIFICATIONS

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

Split System Heat Pump Product & Performance Data

PRODUCT SPECIFICATIONS

SKYPAK II Heating & Cooling Self Contained Packages

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

2TEH3F18A1000A 2TEH3F24A1000A 2TEH3F30A1000A 2TEH3F36A1000A 2TEH3F42A1000A 2TEH3F48A1000A 2TEH3F60A1000A 1½

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

Advance Product Data

Transcription:

036-21024-001 A 550.38-TG2Y (02/00) TECHNICAL GUIDE DESCRIPTION The HDB Series condensing unit is the outdoor part of a versatile system of air conditioning. It is designed to be custom-matched with one of YORK's complete line of evaporator sections, each designed to serve a specific function. Matching Air Handlers are available for upflow, downflow or horizontal application to provide a complete system. Electric heaters are available if required. Add- On coils are available for use with upflow, downflow or horizontal furnaces. FEATURES STELLAR 2000 TM S: H*DB012 THRU H*DB076 (1 Ø & 3 Ø) SPLIT-SYSTEM AIR CONDITIONERS Nominal Capacity: 12 thru 72 MBH Nominal Efficiency: 10.00 SEER QUALITY CONDENSER COILS - The coil is constructed of copper tube and hardened black coated aluminum fins for durability and long lasting efficient operation. The fins on the unit are protected with a decorative grille. PROTECTED COMPRESSOR - The compressor is internally protected against high pressure and temperature. This is accomplished by the simultaneous operation of high pressure relief valve and a temperature sensor which protect the compressor if undesirable operating conditions occur. DURABLE FINISH - Cabinet is made of pre-painted steel. The pre-treated flat galvanized steel provides a better paint to steel bond, which resists corrosion and rust creep. Special primer formulas and glossy earth tone finish insure less fading when exposed to sunlight. LOWER INSTALLED COST - Installation time and costs are reduced by easy power and control wiring connections. Discharge line heat exchanger knockouts are provided, if required. Both quick connect and sweat connect models are available. Both service valves are firmly affixed to the unit. The sweat unit contains enough refrigerant for matching indoor coils and 15 feet of interconnecting piping. The small base dimension means less space is required on the ground or roof. TOP DISCHARGE - The warm air from the top mounted fan is blown up away from the structure and any landscaping. This allows compact location on multi-unit applications. LOW OPERATING SOUND LEVEL - The upward air flow carries the normal operating noise up away from the living area. The rigid top panel effectively isolates any motor sound. Isolator mounted compressor and the rippled fins of the condenser coil muffle the normal fan motor and compressor operating sounds. LOW MAINTENANCE - Long life permanently lubricated motorbearings need no annual servicing. EASY SERVICE ACCESS - Fully exposed refrigerant connections and a single panel covering the electrical controls make servicing easy. SECURED SERVICE VALVES - Secured re-usable service valves are provided on both the liquid and vapor sweat connections for ease of evacuating and charging. FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

550.38-TG2Y (02/00) 036-21024-001 A COOLING CAPACITY - With Air Handler and Coils AIR HANDLER COOLING UNIT COIL * ELECT. HT. KW W RATED NET MBH KW SEER SEER/ CFM TOTAL SENS. TXV EER ** HDB WITH SINGLE SPEED - 1 & 3 Ø H4DB012 N1AHB08 2,5,7.5,10 17 G2FD024S17 650 13.6 10.1 1.42 10.00 9.55 H4DB018 N1AHB08 2,5,7.5,10 17 G2FD024S17 650 18.8 13.9 2.03 10.30 9.25 H4DB024 N1AHB08 2,5,7.5,10 17 G2FD024S17 800 24.8 18.4 2.54 10.50 9.75 N1AHB08 5,7.5,10,15,18 17 G2FD030S17 850 25.0 18.5 2.49 10.60 10.05 N1AHB12 5,7.5,10,15,18 17 G2FD030S17 1000 29.0 21.5 2.91 10.60 9.95 N1AHB12 5,7.5,10,15,18 17 G2FD036S17 1025 30.0 22.2 2.99 10.90 10.02 H4DB036 N1AHB12 5,7.5,10,15,18 17 G2FD036S17 1200 35.6 26.3 3.83 10.20 9.30 N1AHB12 5,7.5,10,15,18 17 G2FD046S17 1250 36.6 27.1 3.77 10.40 9.70 N1AHC16 5,7.5,10,15,20 21 G2FD042S21 1400 39.5 29.2 4.39 10.00 9.00 H4DB042 N1AHB12 5,7.5,10,15,18 17 G2FD046S17 1400 40.0 29.6 4.44 10.00 9.00 N1AHC16 5,7.5,10,15,20 21 G2FD048S21 1450 40.5 30.0 4.45 10.10 9.10 N1AHC16 5,7.5,10,15,20 21 G2FD048S21 1600 47.5 35.2 4.75 10.20 10.00 H4DB048 N1AHD20 7.5,10,15,20,25,30 24 G2FD048S24 1600 47.5 35.2 4.75 10.20 10.00 N1AHD20 7.5,10,15,20,25,30 24 G2FD060S24 1650 49.0 36.3 4.80 10.55 10.20 H4DB060 N1AHD20 7.5,10,15,20,25,30 24 G2FD060S24 1825 58.5 43.3 6.09 10.35 9.60 HDB WITH VARIABLE SPEED - 1 & 3 Ø H4DB018 N1VSB12 5,7.5,10,15,18 17 G2FD024S17 650 19.2 14.2 1.87 11.75 10.25 H4DB024 N1VSB12 5,7.5,10,15,18 17 G2FD024S17 800 25.6 18.9 2.32 11.80 11.05 N1VSB12 5,7.5,10,15,18 17 G2FD036S17 850 26.4 19.5 2.35 12.00 11.25 N1VSB12 5,7.5,10,15,18 17 G2FD036S17 1000 30.0 22.2 2.76 12.20 10.85 N1VSB12 5,7.5,10,15,18 17 G2FD046S17 1025 31.0 22.9 2.79 12.45 11.10 N1VSB12 5,7.5,10,15,18 17 G2FD036S17 1200 36.4 26.9 3.71 10.80 9.80 H4DB036 N1VSB12 5,7.5,10,15,18 17 G2FD046S17 1250 37.0 27.4 3.66 11.10 10.10 N1VSC16 5,7.5,10,15,20 21 G2FD048S21 1200 38.0 28.1 3.65 11.70 10.40 H4DB042 N1VSC16 5,7.5,10,15,20 21 G2FD048S21 1450 41.0 30.3 4.23 11.00 9.70 H4DB048 N1VSC16 5,7.5,10,15,20 21 G2FD048S21 1600 48.5 35.9 4.53 11.30 10.70 N1VSD20 7.5,10,15,20,25,30 24 G2FD060S24 1650 50.5 37.4 4.47 11.90 11.30 H4DB060 N1VSD20 7.5,10,15,20,25,30 24 G2FD060S24 1825 59.5 44.0 5.59 11.10 10.65 HDB WITH SINGLE PIECE - 1 Ø ONLY H4DB012 F2RP/FP018 2,5,8 18 650 13.1 9.7 1.41 10.00 9.30 H4DB018 F2RP/FP018 2,5,8 18 650 18.0 13.3 2.00 10.00 9.00 F2RC/FC024 5,8,10 18 650 18.5 13.7 2.03 10.50 9.10 F2RC/FC024 5,8,10 18 800 23.0 17.0 2.47 10.00 9.30 H4DB024 F2RP/FP024 5,8,10 18 800 23.8 17.6 2.62 10.20 9.10 F2RP/FP030 5,8,10,15 18 800 24.0 17.8 2.61 10.40 9.20 F2RC/FC030 5,8,10,15 18 1035 28.0 20.7 2.92 10.40 10.50 9.60 F2RC/FC036 5,8,10,15 18 1035 29.0 21.5 2.99 10.50 9.70 F2RP/FP030 5,8,10,15 18 1035 29.0 21.5 2.96 10.55 9.80 F2RP/FP036 5,8,10,15 21.5 1035 29.8 22.1 3.01 10.80 11.00 9.90 F2RC/FC036 5,8,10,15 18 1250 35.4 26.2 3.73 10.10 9.50 H4DB036 F2RP/FP036 5,8,10,15 21.5 1250 36.8 27.2 3.81 10.50 9.65 F2RP/FP042 5,8,10,15 21.5 1250 37.0 27.4 3.85 10.50 9.60 H4DB042 F2RP/FP042 5,8,10,15 21.5 1400 39.5 29.2 4.44 10.00 8.90 F2FP048 10,15,20,25 24 1400 40.5 30.0 4.45 10.10 9.10 H4DB048 F2FP048 10,15,20,25 24 1600 48.0 35.5 4.82 10.05 9.95 F2FP060 10,15,20,25 24 1600 49.0 36.3 4.97 10.20 9.85 H4DB060 F2FP060 10,15,20,25 24 1850 57.0 42.2 6.13 10.00 10.20 9.30 HDB WITH COMMERCIAL, BELT DRIVE KEU EVAPORATOR BLOWR UNIT - 1 & 3 Ø H4DB060 K2EU060 10,16,25 36 2000 55.5 39.5 6.30 10.00 H4DB076 K4EU090 10,16,25,36 52 2550 72.0 49.8 7.80 9.80 *. Refer to coil installation guide for proper coil application.. Standard Cooling Operation is limited to 45 F outdoor ambient.. To meet $=4.2 insulation requirements, substitute F2FC for F2RC models. All ratings remain the same. **. EER (Energy Efficiency Ratio) is the total cooling output in BTU s is at a 95 F outdoor ambient divided by the total electric power in watt-hours at those conditions. Rated in accordance with DOE test procedures (Federal Register 12-27-79 + 3-18-88) and ARI Standards 210. MBH based on 80...entering air temperature, 50% RH, and rated air flow. KW includes compressor, outdoor fan and indoor blower motor watts. Add-on coils include 365 watts/1000 CFM for blower motor. SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU s during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period. 2 Unitary Products Group

036-21024-001 A 550.38-TG2Y (02/00) COOLING CAPACITY - With Upflow, Downflow and Horizontal Furnace and Coils UNIT FURNACE * COIL NOMINAL AIRFLOW W RATED CFM TOTAL NET MBH SENS. COOLING H4DB012 800 ** 14,17 G1UA024S14,17 450 13.6 10.1 1.4 10.00 9.45 G1HD024S 450 13.9 10.3 1.4 10.10 9.60 14,17 G2FD024S14,17 450 13.6 10.1 1.4 10.00 9.55 H4DB018 H4DB024 H4DB036 800 1000 800 1200 1400 1000 1200 1400 1200 1400 1600 KW SEER SEER / TXV 14,17 G1UA024S14,17 600 18.4 13.6 2.0 10.15 9.10 14,17 G2FD024S14,17 600 18.8 13.9 2.0 10.30 9.25 14 G1UA030S14 650 18.8 13.9 2.0 10.30 9.25 G1HD024S 600 18.9 14.0 2.0 10.30 9.30 17 G2FD030S17 650 19.0 14.1 2.0 10.50 9.35 14 G2FD035S14 650 19.0 14.1 2.0 10.50 9.35 17 G1NA030S17H 650 19.0 14.1 2.0 10.50 9.35 G1HD024S 800 23.2 17.2 2.5 10.25 9.35 17 G1NA030S17H 825 24.4 18.1 2.5 10.20 9.85 14,17 G1UA024S14,17 800 24.6 18.2 2.5 10.30 9.95 14,17 G2FD024S14,17 800 24.8 18.4 2.5 10.50 9.75 14 G1UA030S14 850 24.8 18.4 2.5 10.50 9.75 17 G2FD036S17 850 25.4 18.8 2.5 10.70 10.20 G1HD036 850 25.6 18.9 2.6 10.80 9.95 14 G1UA030S14 1000 28.8 21.3 2.9 10.60 9.90 17,21 G1UA036S14 1000 29.0 21.5 2.9 10.80 10.00 17,21 G1UA036S17,21 1025 29.0 21.5 2.9 10.80 10.00 14,17 G2FD030S14,17 1000 29.0 21.5 2.9 10.60 9.90 14 G2FD035S14 1000 29.0 21.5 3.0 10.75 9.70 17 G1NA030S17K 1000 29.4 21.8 2.9 10.60 10.05 21 G2FD042S21 1000 30.0 22.2 3.0 11.00 10.10 17 G2FD046S17 1025 30.0 23.2 3.0 11.00 10.05 17 G1UA048S17 1025 30.0 24.2 2.9 11.00 10.20 G1HD036 1025 29.4 21.8 3.0 10.70 9.95 21 G2FD036S21 1025 30.0 22.2 3.0 11.00 10.05 17 G2FD036S17 1025 30.0 22.2 3.0 10.90 9.95 17,21 G1UA036S17,21 1200 35.4 26.2 3.8 10.00 10.15 9.30 14 G1UA036S14 1200 35.4 26.2 3.8 10.00 9.30 14 G2FD035S14 1200 35.2 26.0 3.8 10.00 9.35 21 G1NA048S21D 1225 36.8 27.2 3.8 10.40 9.65 17 G1NA036S17D 1225 35.0 25.9 3.9 10.00 8.90 17 G1NA036S17J 1225 35.6 26.3 3.8 10.20 9.40 21 G1NA036S21C 1225 35.6 26.3 3.8 10.20 9.40 17 G1UA048S17 1225 37.0 27.4 3.8 10.55 9.70 21,24 G1UA048S21,24 1250 37.0 27.4 3.8 10.60* 9.75 G1HD036S 1225 35.4 26.2 3.8 10.00 9.30 21 G2FD042S21 1225 36.8 27.2 3.8 10.40 9.65 21,24 G2FD048S21,24 1250 37.2 27.5 3.8 10.60* 9.85 17 G2FD046S17 1225 36.6 27.1 3.8 10.40 9.55 21 G2FD036S21 1225 36.8 27.2 3.9 10.30 9.50 M3HD048S 1225 35.0 25.9 3.9 10.00 9.05 G1HD048 1250 36.8 27.2 3.8 10.20 9.60 *. Refer to Quick Selection Chart for specific furnace matchup.. Refer to coil installation guide for proper coil application.. Standard Cooling Operation is limited to 45 F outdoor ambient. **. This application is not recommended in areas where latent cooling is required..field transition required between furnace and coil. EER See Notes on page 2. Unitary Products Group 3

550.38-TG2Y (02/00) 036-21024-001 A COOLING CAPACITY - With Upflow, Downflow and Horizontal Furnace and Coils (Continued) UNIT H4DB042 H4DB048 FURNACE * COIL NOMINAL AIRFLOW 1400 1600 2000 1600 2000 H4DB060 2000 W RATED CFM TOTAL NET MBH SENS. COOLING KW SEER SEER / TXV 21 G1NA048S21D 1400 39.5 29.2 4.4 10.00 9.05 21 G2FD042S21 1400 39.5 29.2 4.4 10.00 9.00 21,24 G1UA048S21,24 1425 40.0 29.6 4.4 10.00 9.10 ** M3HD048S 1400 40.0 29.6 4.3 10.00 9.30 ** G1HD048 1400 40.0 29.6 4.4 10.00 9.10 17 G2FD046S17 1400 40.0 29.6 4.4 10.00 9.00 21,24 G2FD048S21,24 1425 40.5 30.0 4.5 10.10 9.10 24 G2FD060S24 1450 41.0 30.3 4.4 10.20 9.25 21 G1NA048S21D 1600 44.5 32.9 4.7 10.00 9.40 ** M3HD048S 1600 47.0 34.8 4.8 10.20 9.85 ** G1HD048S 1600 46.0 34.0 4.8 10.00 9.50 17 G2FD046S17 1600 46.5 34.4 5.1 10.00 9.10 21,24 G2FD048S21,24 1600 47.5 35.2 4.8 10.20 10.00 21,24 G1UA048S21,24 1600 47.5 35.2 4.8 10.20 9.95 21,24 G1UA060S21,24 1620 49.0 36.3 4.8 10.55 10.20 24 G2FD060S24 1620 49.0 36.3 4.8 10.55 10.20 v M3HD060S 1600 47.0 34.8 4.8 10.20 9.85 ** G1HD060 1620 49.0 36.3 4.8 10.30 10.20 21,24 G1UA060S21,24 1850 57.5 42.6 6.0 10.30 9.55 ** M3HD060S 1850 58.0 42.9 6.1 10.00 9.55 ** G1HD060 1850 57.5 42.6 6.0 10.00 9.55 24 G2FD060S24 1850 58.5 43.3 6.1 10.35 9.60 *. Refer to Quick Selection Chart for specific furnace matchup.. Refer to coil installation guide for proper coil application.. Standard Cooling Operation is limited to 45 F outdoor ambient. **. Field transition required between furnace and coil. EER 4 Unitary Products Group

036-21024-001 A 550.38-TG2Y (02/00) COOLING PERFORMANCE H4DB012 H4DB018 H4DB024 SUCT. T/P @ AIR TEMP ON CONDENSER SUCT. T/P @ AIR TEMP ON CONDENSER COMPR. 75 F 95 F 115 F COMPR. 75 F 95 F 115 F TEMP. PSIG MBH KW MBH KW MBH KW TEMP. PSIG MBH KW MBH KW MBH KW 35 61.5 13.2 1.14 11.2 1.24 9.2 1.34 35 61.5 39.9 3.43 30.8 3.62 22.5 3.81 40 68.5 14.7 1.17 12.6 1.28 10.4 1.40 40 68.5 44.1 3.55 34.3 3.76 25.2 3.97 H4DB036 45 76.0 16.4 1.21 14.0 1.33 11.6 1.46 45 76.0 48.3 3.67 37.8 3.89 28.1 4.11 50 84.0 18.0 1.24 15.5 1.37 12.8 1.51 50 84.0 52.7 3.78 41.5 4.02 31.1 4.25 35 61.5 17.3 1.38 14.7 1.51 12.0 1.66 35 61.5 37.4 3.20 32.1 3.49 26.7 3.71 40 68.5 19.3 1.43 16.5 1.58 13.7 1.74 40 68.5 41.5 3.37 35.8 3.67 30.1 3.92 H4DB042 45 76.0 21.4 1.48 18.4 1.65 15.4 1.83 45 76.0 45.7 3.52 39.5 3.85 33.0 4.14 50 84.0 23.5 1.53 20.4 1.73 17.1 1.92 50 84.0 49.7 3.67 43.3 4.01 36.3 4.33 35 61.5 27.0 1.84 21.6 2.02 16.5 2.17 35 61.5 45.0 3.28 40.1 3.98 35.2 4.81 40 68.5 29.9 1.90 24.1 2.11 18.7 2.29 40 68.5 49.1 3.35 43.9 4.07 38.7 4.91 H4DB048 45 76.0 33.0 1.97 26.7 2.19 20.9 2.40 45 76.0 53.3 3.43 47.9 4.15 42.4 5.02 50 84.0 36.0 2.02 29.4 2.28 23.3 2.51 50 84.0 57.6 3.52 51.9 4.24 46.1 5.12 35 61.5 29.1 2.48 23.0 2.66 17.4 2.81 35 61.5 53.6 4.21 48.3 4.99 42.8 5.90 40 68.5 32.5 2.58 25.8 2.77 19.6 2.93 40 68.5 58.4 4.31 52.8 5.10 47.1 6.03 H4DB060 45 76.0 36.0 2.68 28.7 2.88 21.9 3.06 45 76.0 63.4 4.42 57.6 5.21 51.5 6.16 50 84.0 39.5 2.78 31.6 2.99 24.3 3.18 50 84.0 68.6 4.53 62.4 5.33 56.1 6.29 35 61.5 69.6 5.06 61.4 5.82 53.0 6.53 H4DB076 40 68.5 76.8 5.21 67.9 6.04 58.9 6.81 45 76.0 84.3 5.35 74.9 6.23 65.3 7.07 50 84.0 91.9 5.48 82.0 6.42 71.9 7.31 NOTES: 1. For condensing unit only. Does not include effect of evaporator motor power or heat. 2. Performance based on 15 superheat and 15 sub-cooling at condensing unit. a. Increase capacity 1% for each 2 increase in sub-cooling. b. Decrease capacity 1% for each 2 decrease in sub-cooling. 3. Sub-cooling in excess of 20 may result in excessively high condensing temperature with air on condenser above 115 F. Maximum recommended condensing temperature is 140 F. SOUND RATINGS H - DB SOUND RATING DECIBELS 012 76 018 76 024 76 030 78 036 78 * 042 78* 048 78* 060 78* 076 80* *. Compressor Blanket Factory Installed. CERTIFICATION APPLIES ONLY WHEN USED WITH PROPER COMPONENTS AS LISTED WITH ARI Unitary Products Group 5

550.38-TG2Y (02/00) 036-21024-001 A TYPICAL FIELD WIRING - 1 Ø ALLFIELDWIRINGTOBEINACCORDANCEWITHNATIONALELECTRICALCODE(NEC)AND/ORLOCALCODES POWERWIRING 208/230-1-60 230-1-50 24VOLTCONTROLWIRING Minimum18GA. Wire (NECClass2) FURNACEORAIRHANDLERTERMINALBLOCK POWER CONTROL FACTORY C Y R G W GROUND SCREW CONTACTOR TERMINALS COIL * Y R G W ROOMTHERMOSTAT *TerminalWisonly requiredonsystems withheat. ALLOUTDOORWIRINGMUSTBEWEATHERPROOF. USECOPPERCONDUCTORSONLY. POWER WIRING CONTROL WIRING TYPICAL FIELD WIRING - 3 Ø ALLFIELDWIRINGTOBEINACCORDANCEWITHNATIONALELECTRICALCODE(NEC)AND/ORLOCALCODES POWERWIRING 208/230-3-60 460-3-60 575-3-60 380/415-3-50 24VOLTCONTROLWIRING Minimum18GA. Wire (NECClass2) POWER CONTROL FACTORY FURNACEORAIRHANDLERTERMINALBLOCK C Y R G W CONTACTOR TERMINALS GROUND SCREW COIL * Y R G W ROOMTHERMOSTAT *TerminalWis onlyrequired onsystems withheat. ALLOUTDOORWIRINGMUSTBEWEATHERPROOF. USECOPPERCONDUCTORSONLY. 6 Unitary Products Group

036-21024-001 A 550.38-TG2Y (02/00) TYPICAL INSTALLATION TO INDOOR BLOWER THERMOSTAT TO POWER SUPPLY NEC CLASS 1 WIRING WEATHERPROOF DISCONNECT SWITCH 48 OVERHEAD CLEARANCE 12 REAR AND SIDES NEC CLASS 2 WIRING TO COIL 24 SERVICE ACCESS CLEARANCE NOTE: All outdoor wiring must be weatherproof Seal opening(s) with permagum or equivalent ACCESSORIES Refer to Price Manual for specific model numbers. Start Assist Kit - Provides increased starting torque for areas with low voltage conditions. Hard Start Kits - Provides required starting torque for use with Solenoid Valve Kit. Compressor Blanket - Designed to further reduce the normal operating sounds for H*DB units. Refer to price pages for specific matchup. Off Cycle Timer - Provides a 5 minute off cycle to prevent rapid recycling of the compressor. Room Thermostats - A wide selection of matching thermostats is available to provide features required for any installation. 2TH07701024 - One stage heat / One stage cool / Nonprogrammable, manual changeover. 2ET07700224 - One stage heat / One stage cool / Programmable, Electronic, manual changeover with subbase. 2ET07700324 - One stage heat / One stage cool / Programmable, Electronic, manual changeover, built-in anti-short cycle timer. Blower Off Delay - Available to increase efficiency when using Yorkmate control. Installs on indoor section to maintain blower operation for approximately 1 minute on shutdown. Unitary Products Group 7

MATCHING INDOOR COMPONENTS Add-On Coils - For Furnace Application Air Handlers - For Non-Furnace Application G-UA COIL G-HD COIL N-AH BLOWER/ G+FD COIL UPFLOW DOWNFLOW HORIZONTAL G+FD COIL F2RC / F2FC OR F2RP / F2FP FAN COIL UNITS G-NA COIL UPFLOW HORIZONTAL G-NF COIL Subject to change without notice. Printed in U.S.A. 036-21024-001 A Copyright by Unitary Products Group 2000. All rights reserved. Supersedes: 550.38-TG2Y (1299) 550.38-TG2Y (0200) Unitary 5005 Norman Products York OK Group Drive 73069