The Emergence of Triboelectric Technology

Similar documents
Dust Alert 75. *shown with optional external keypad and display

THE INDUSTRIAL APPROACH TO DUST MONITORING

PARTICULATE EMISSION MONITORING

DFE T ECHNOLOGY. At Conceptronic, the design and management process for reflow soldering systems is called Dynamic Flow Engineering, or DFE.

Providing State-of-the-Art Fine Particulate Control Through Advanced High Energy Ionization

DUST COLLECTION TRAINING. Revision 2013

Emissions monitoring solutions

THEORY OR OPERATION 2 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 OPTIONS 11

Brine Generation Study

Boiler Draft Equipment

Specifications - Installation and Operating Instructions 2X 1/2 NPT OR M20 ELECTRICAL ENTRY. 3/4 NPT or 3/4 BSPT 5/8 [15.88]

Conducting a NFPA 652 Dust Hazard Analysis (DHA): Practical Tips & Approaches

S304 and S305 Dust Emission Monitors. User Manual. Distributor

APPLICATION PROFILE EXPLOSIONS IN CEMENT PLANTS EXPLOSIONS IN CEMENT PLANTS CEMENT PLANT EQUIPMENT WITH HIGHEST EXPLOSION POTENTIAL. Form No.

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

DESCRIPTION AND SPECIFICATION

724A. DustAlarm. Broken Bag Detector. DustAlarm ever requires service either in or out of warranty, please

COMBUSTION APPLIANCE SAFETY INSPECTION FOR VENTED APPLIANCES*

Identifying and Preventing Dust Fire and Explosion Hazards

THE NEXT GENERATION IN VISIBILITY SENSORS OUTPERFORM BOTH TRADITIONAL TRANSMISSOMETERS AND FORWARD SCATTER SENSORS

COURSE 474 CONTINUOUS EMISSION MONITORING Extended Agenda

TubeJet Dust Collector Application Guide. Top or Side Bag Removal Rectangular Cylindrical Low or High Pressure

Dust Concentration Meter

compressed air or left to consume air even when the associated production machine has been turned off.

venting method will work for all pressure conveying systems, analyzing your available equipment, your material s characteristics, and your conveying c

HFID Heated Total Hydrocarbon Analyzer Module

BHA Powerwave Acoustic Cleaning Systems Powerful cleaning to help increase performance

Reducing the Cost and Risk of Dust Collection in Coal

C-NRPP Quality Assurance Guidance for Radon Test Devices

THE STANDARD OF EXCELLENCE WDG-V SERIES COMBUSTION ANALYZERS

PRODUCT CONFORMITY CERTIFICATE

Kice Dust Control System Design and Maintenance Basics Design, Maintenance, & Operation

Ontario Fire Code SECTION 5.10 COMBUSTIBLE DUST PRODUCING PROCESSES. Illustrated Commentary. Office of the Ontario Fire Marshal

Weatherization Assistance Program (WAP) Space Heater Policy

Boiler MACT Deadline Is Here, Are You In Compliance? Sponsored by

ROTARY DRYER CONSTRUCTION

Air Pollution Control Equipment & Service Needs

Improving Air Emission Profiles Using Baghouses and Other Processes EVRAZ INC NA Canada Environmental Affairs Department

Zirconia Oxygen Gas Analyzers

CERTIFICATE of Product Conformity (QAL1 )

THE CORPORATION OF THE CITY OF LONDON. POTTERSBURG POLLUTION CONTROL PLANT FILTER BUILDING ODOUR CONTROL Tender No ADDENDUM NO.

TSI AEROTRAK PORTABLE PARTICLE COUNTER MODEL 9110

Pulse Jet Baghouse ASTEC PULSE JET BAGHOUSE. for Asphalt Facilities

To familiarize you with typical baghouse operation and maintenance problems.

Improved Dryer Control

Objectives. NFPA Dust Specific Documents. Combustible Dust Process Hazard Safety Overview of NFPA Standards for Combustible Dusts

Snifter. User Manual. Distributor

PRODUCT CONFORMITY CERTIFICATE

[1] Lecture 2 Particulate emission control by mechanical separation & wet gas scrubbing

PRIMATECH WHITE PAPER PROCEDURE FOR DUST HAZARD ANALYSIS (DHA)

INSTRUCTIONS. Duct Mount Kit Q900. Description. Operation

MONITORING & CONTROL. the expert approach. Dust Sensors.

Residential Air Leakage (Blower Door) Testing for Florida Code Compliance

ASKING THE RIGHT QUESTIONS ABOUT CARTRIDGE DUST COLLECTION

Sintrol Snifter A1+ Manual. Version 1.2.2

United States Patent (19)

Combustible Dust Issues

BP Alaska GC-1. Design Review Project. January 2003

F-1100 Series Single Turbine Meters Suitable for pipe sizes 1 ¼ and larger.

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA PARTICULATES

A. Base Bid: 1. Heating Contractor provide: a. Control sequences for HVAC systems, subsystems, and equipment.

PRODUCT CONFORMITY CERTIFICATE

Effective Biomass Moisture Control

Handling Petroleum Products & Static Ignition Hazards Introduction

THERMAX Efficiency Monitor

Understanding. Combustible Dust Hazards: Basic Measures to Ensure the Safety of Combustible Dust Handling Operations

INDUSTRIAL BLOWERS. With over 70 years of experience and expertise our fans will ensure your projects are a success.

VARIO eco Dust Collector. For the highly effective, energy efficient collection of dust from industrial processes. Standard for clean air

15900 HVAC INSTRUMENTATION AND CONTROLS

Heat Recovery Units. Heat Recovery 1

Ronan Model X96S Series Weighing System

Ronan Model X96S Series Density System

4500MkIII COMPLIANCE OPACITY AND DUST MONITORING QAL 1 PS-1 ASTM D6216 PROCEDURE 3 PS-11 QUALITY CUSTOMER SOLUTIONS

PRODUCT CONFORMITY CERTIFICATE

PERFORMANCE OF A MODEL IN-LINE VORTEX SEPARATOR. Keng-Choon Lee Geothermal Institute, The University of Auckland, Private Bag 92019, Auckland, New

Quality Assurance/ Quality Control. Topic 4 - Audio 46. Key Points

Dust Collection Tips to Keep Free-From Foods Safe from Cross-Contamination

Dust Collectors. Unique Design & Engineering Approaches for Dust Collection and Pneumatic Conveying

Eliminating Condensation and Resulting Corrosion. Sulphur Tail Gas and De-Gas Lines

Meets all design requirements of U.S.EPA. Double pass optical system for accuracy and sensitivity. Modulated light beam to eliminate interference

This guide will discuss the scope of work, and technical requirements of connecting to the Energy Transfer Station(s) (herein referred to as ETS).

Lecture 5 Particulate emission control by electrostatic precipitation

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

Lab 12E, 12F, 2E: Acid Rain and Seeds

LAB 8. FIGURE L8.1 A rock sculpted by wind erosion in the Altiplano region of Bolivia. FIGURE L8.2 A dust storm in Casa Grande, Arizona

Specifications. Table of contents. 2:Specification. 3:Composition. 4:Instruments outside figure

Discover the Difference

HOW WELL DO YOU KNOW YOUR DUST?

Demand-Controlled Ventilation For Commercial Kitchens

Monitoring Flammable Vapors and Gases in Industrial Processes

Moisture can be very disruptive to a dust. Preventing moisture problems in your dust collector

IMR Environmental Equipment, Inc Central Ave. St. Petersburg, FL Phone:

COMBUSTIBLE DUST HAZARD MITIGATION

LMV52 Control. Specifications. Document No. LV February 3, Product Description. Sample Specification

Advanced Technology High-Ratio Pulse Jet Baghouse Dust Collectors

BTEC Standard

International comparison of validation methods for dust concentration measurement

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA

Snifter ATEX22 VERSION. User Manual. Distributor

General Design Practices in Reducing Risk in Grain Handling Facilities

Transcription:

September 1998 September 1998, Pollution Engineering The Emergence of Triboelectric Technology Triboelectric monitoring, now accepted by the U.S. Environmental Protection Agency, provides continuous monitoring of particulates. Kay Ramsey For almost two decades, opacity monitoring and periodic stack testing were the only methods of particulate monitoring accepted by the U.S. Environmental Protection Agency (EPA). Although a patented triboelectric technology was invented more than 25 years ago and more than 20,000 installations worldwide were using triboelectric products to monitor baghouses for leak detection prior to the Clean Air Act Amendments (CAAA) of 1990, EPA continued to view it as somewhat experimental. Along with the CAAA came the requirement for EPA to develop National Emission Standards for Hazardous Air Pollutants (NESHAPs) under Title III, and the Compliance Assurance Monitoring (CAM) Rule under Title V. Both of these regulatory actions involve particulate monitoring definition in the form of bag leak detection. The recently promulgated maximum achievable control technology (MACT) standard for the secondary lead smelting industry was the first regulatory action to change the requirement from exclusively opacity monitoring and periodic stack testing to triboelectric bag leak detection. Most of the secondary lead smelters had been using triboelectric bag leak detectors for many years and had demonstrated their successful use on blast and reverb furnaces, as well as on the general ventilation baghouses. This significant action came only after extensive, independent field testing of triboelectric technology by EPA, which led to the preparation and publication of an EPA document titled Fabric Filter Bag Leak Detection Guidance. This document provides guidance on the use of triboelectric monitors as fabric filter bag leak detectors. Figure 1. Opacity uses a light path to analyze dust particles in the gas stream. The recently proposed MACT standard for the mineral wool production industry has followed a similar direction. In this proposal, EPA states that "opacity is not a good indicator of performance at the low, controlled levels characteristic of these sources." Opacity Opacity, or optical technology, measures the reduction in light transmittance across a stack, using a transmitter and a receiver (lenses). The process uses a single- or double-pass light path to analyze the presence of dust particles in the gas stream. Opacity monitors compare the amount

of lost light energy to the total energy of the transmitted light, and translate the signal into a percentage of opacity. Opacity monitors were the first instruments able to continuously monitor opacity. However, they provide only a relative indication of gross change in particulate concentration in a stack. If two facilities have opacity levels of 10 percent, their actual particulate emissions still can be different. The reading can be affected by misalignment of the lenses, clouding of the lenses, atmospheric conditions, the color of the particulate, fumes in the gas stream and other factors. Opacity is not an accurate or reliable method for detecting the early onset of bag leaks. As EPA has recognized, opacity is not appropriate for monitoring low-level bag leaks. The minimum detection ranges of the various methods are: Opacity monitors 0.0010 g/dscf (grains per dry cubic foot) Method 5 stack test 0.0030 g/dscf Triboelectric 0.000002 g/dscf [(0.005 milligrams/meters 3 (mg/m 3 )][1] The table on the next page provides results of a test comparing sidescatter opacity technology with triboelectric technology at an aluminum reduction facility. The shaker baghouse system included 12 compartments of 300 filter bags each, for a total of 3600 filter bags. All 12 compartments exhausted through a 17-foot diameter stack in which both the opacity device and the triboelectric probe were installed. A 1 / 4 -inch hole was punched in one of the 3600 filter bags and was detected by the triboelectric device in the first 50-minute cleaning cycle; the leak was not detected for two days by the opacity device. The triboelectric effect Static electrification is a familiar phenomenon. Not so commonly known is the reason why materials become statically charged. The charging mechanism is the principle of triboelectric measurement. Static electrification depends upon an excess or imbalance of electrical charge, which may be produced by the transfer of charge when two materials are brought together and then separated or rubbed together. This phenomenon is referred to as the triboelectric effect. Figure 2. A charge transfer results when particles come close to an electrically isolated probe.

Figure 3. Several factors affect the triboelectric signal. When particles conveyed in a pipe or duct collide, or come close to an electrically isolated and earth-grounded intrusive probe, a charge transfer results between the particles in the gas stream and the probe. It takes place on a continuous basis, because of the continuous stream of particles. The CAAA bag leak detection requirements have given rise to patented triboelectric technologies. The primary difference between them is the type of circuits. The triboelectric signal is made up of: The DC component generated by the particulate striking the sensor. It is proportional to the mass flow and varies with the actual flow rate. The low-frequency AC component generated by short-term intermittent variations or fluctuations in the mass flow rate of particulate, and by particulate passing near the probe, but not impacting the probe. The high-frequency AC component. This is the high-frequency modulation resulting from equipment, vibration and other factors. The high-frequency AC component must be filtered out. Only the DC component and the lowfrequency AC component are useful. Early in the development of triboelectric devices, engineers recognized the advantages of the DC measurement in providing robust and linear signals. They also found that at low velocities and concentrations, the DC component becomes smaller than the AC component of the signal. For this reason, some triboelectric technology incorporates a special circuit that automatically reports the larger of the two components. The technologies utilizing subsets of traditional triboelectric measurement (non-contact electrification and electrodynamic measurement) also filter out the high-frequency AC component, but they rely completely on the low-frequency AC component for a signal. The factors that affect all triboelectric signals can be expressed as I = KCV 2, where: I = the triboelectric signal or current K = the calibration factor of the particulate material C = mass concentration of the particulate impinging on the probe V = velocity of the gas stream Each material exhibits a different K factor. The signal also increases with velocity by a square root relationship, whether using DC or AC components. The material and velocity are fairly constant in most baghouses, with the result that the signal follows the changes in the mass concentration, except when only the AC component is used.

Optical Technology vs. Triboelectric Technology Time to: Optical sensor Triboflow sensor Detect leak Two days Less than one hour Locate leak Two to three manhours Less than one minute Clean up leak Eight to 10 man-hours Less than one man-hour Puncture detected 80 hole 1/4-in. hole Dust cleanup 60+ cubic feet 2.5 cubic feet Cleanup tool Shovels Shop vacuum AC-coupled circuits using only the AC components are completely dependent on fluctuations in the dust flow signal to function. If fluctuation or turbulence does not exist in the case of laminar flow, the dust will not be detected. If the degree of fluctuation varies to any extent, the dust flow will be detected at significantly lower or higher amounts than actually are present. Significant changes take a long time to settle down. These can be interpreted as changes in particulate concentration because there is no way to know the difference. The AC magnitude changes from 2 percent to 6 percent during this stepped flow velocity change from 1000 feet/minute to 8000 feet/minute. See Figure 4, below. The recently proposed MACT standard for the mineral wool production industry has followed a similar direction. In this proposal, EPA states that "opacity is not a good indicator of performance at the low, controlled levels characteristic of these sources." Figure 4. The AC magnitude changes from 2 percent to 6 percent during this stepped flow velocity change. One would not expect to see this kind of change in a baghouse, but the magnification helps to demonstrate the huge anomalies that occur with significant changes in turbulence or air flow. Notice that after the changes, which occurred over a three-minute period, the baseline was 20 percent higher. Over time, it will return to normal, but in the interim, it could be interpreted as an increase in particulate concentration, leading the facility to report an exceedance when none occurred. AC-coupled devices try to detect the small flow deviations while filtering out all high-frequency AC noise. To correct for this inadequacy, a fairly large averaging time is required to obtain a steady signal, and critical information is lost. In addition to being non-linear, the long averaging time will

mask important low-frequency AC component signals such as those caused by cleaning cycles in baghouses, an important indicator of bag wear. A linear signal directly proportional to the mass concentration is necessary if the signal is to be used for trending or diagnostic purposes. The DC-coupled circuits provide a linear signal directly proportional to the mass concentration. AC-coupled signals reflect a square root of concentration. The DC signal is linear with concentration as demonstrated in Figure 5, which shows the AC and the DC signals at a constant velocity but various concentrations. Figure 5. A linear signal directly proportional to the mass concentration is necessary for diagnostic purposes. AC-coupled circuits make acceptable broken bag detectors. They can indicate gross failure and can be used quite effectively for small nuisance collectors or bin vents. But to comply with EPA regulations, which require continuous 4-20 milliamps (ma) bag leak detectors and accurate records able to prove continuous compliance, AC-coupled circuits might not work. In EPA's Fabric Filter Bag Leak Detection Guidance, the Agency concludes: "Charge transfer (triboelectric) monitors based on electrostatic induction (AC coupled) are also potentially applicable, but sufficient information was not available to include them in this guidance." Without large numbers of AC-coupled triboelectric devices in various industries over an acceptable evaluation period, it would be irresponsible for EPA to embrace this technology. The NESHAPs standards are specific about monitoring technology requirements. CAM, finalized in October 1997, allows more flexibility in the selection of a monitoring protocol. A facility is not required to select instrumentation monitoring. It can select visual observation, differential pressure, mass balance formulas, combustion source feed rates or another method. It can write a CAM plan around any monitoring technology that will provide information which reliably indicates potential problems in the air pollution control equipment and allows the facility to act in a timely fashion. If the method alerts the facility to a problem at about the same time visible emissions begin to occur, the facility might report exceedances rather than excursions. Visual observation and opacity monitoring may be unacceptable for low-level particulate rate limits. Differential pressure monitoring is only an indication of blinded filter bags. There are more reasons for installing bag leak detection technologies than complying with specific requirements. It is not possible to have an effective dust collector O&Mprogram that can be used for predictive maintenance and trending without continuous monitoring. Triboelectric bag leak detection is more reliable in detecting early bag leaks than opacity monitoring. When considering improved operating and maintenance programs for air pollution control equipment, annual certification of continuous compliance under the Title V permit program should be considered, as well as the implications of the Any Credible Evidence (ACE) Rule. When

selecting a monitoring method or technology, facility managers should ask themselves the following questions: 1. Does the monitoring method selected provide a reliable (95 percent or better) method of detecting bag leaks? 2. Does the monitoring method selected provide the level of assurance necessary for a corporate executive to sign a certification of continuous compliance with complete confidence? 3. Does the monitoring method provide the data needed to demonstrate continuous compliance? If these questions can be answered confidently, then the correct choice has been made. References 1. Rust Report prepared for the Institute for Polyacrylate Absorbents Inc. Regulatory Impact Title III of the Clean Air Act, MACT standards Title Vof the Clean Air Act, CAM Rule. Pollution Engineering - September, 1998