PREVENTING COOKING FIRES

Similar documents
PROFESSIONAL KITCHEN CLEANING. New Kitchen Ventilation Systems supplied and fitted at competitive rates

OPERATING & MAINTENANCE INSTRUCTIONS FOR EXTRACTION SYSTEMS

MARKET LEADERS IN LARGE SCALE COMMERCIAL CLEANING SERVICES

FIRE SAFETY INSPECTIONS

COMMERCIAL KITCHEN FIRE SAFETY

Catering extract ventilation: a fire risk assessment by the responsible person

Checklist For Building Inspection & Fire Safety

Exhaust Duct Design Page 1 of (C)

Swiftclean and ANSUL. AXA s Commercial Kitchen Fire Safety Service. Ansul is a leading brand of Johnson Controls International PLC

Flue Fire Prevention Awareness

FIRE RISK ASSESSMENT Self Assessment

Fire and Life Safety Review Form

Fire safety in restaurants. CFPA-E Guideline No 9:2012 F

Maintenance of Fire Systems

First Revision No. 49-NFPA 17A-2015 [ Detail ] Submitter Information Verification. Committee Statement 7/30/2015 1:35 PM

Fixed fire protection solutions

Fire Risk Assessment Case Study

Slight Harm Moderate Harm Extreme Harm Low Trivial Risk Tolerable Risk Moderate Risk Medium Tolerable Risk Moderate Risk Substantial Risk

Project Name: Project Address: Installer Name: Installer Address: Date of Inspection:

It is critical to maintain the Beech Oven and associated equipment on a regular basis, to avoid the possibility of a serious fire or malfunction.

Winnipeg Fire Department Fire Prevention Branch

Fire Risk Assessment. Guidance Notes. Location details. Risk Rating. Assessors. General notes

Fire Risk Assessment

Checklist For Life Safety

AFEC FIRE ENGINEERING TEMPLATE FOR CLIENTS INTERNALLY COMPLETED RISK ASSESMENT

Ecolibrium. Cooling the cloud THE OFFICIAL JOURNAL OF AIRAH OCTOBER 2016 VOLUME 15.9 RRP $14.95 PRINT POST APPROVAL NUMBER PP352532/00001

CORPUS CHRISTI FIRE PREVENTION MOBILE FOOD VENDOR REQUIREMENTS

Fire safety management issues identified by fire risk assessments

Fire Safety Audit: Part B - Questionnaire (Questionnaire Devised By Mr.R.R.Nair) Yes No x

Tents and Temporary Membrane Structures Packet

LA AUDIT ASSISTANCE SURVEY: Pre-survey checklist

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT HORSEFAIR HOUSE

for fish and chip frying ranges

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT SPORTS CENTRE

Black Diamond Fire Department Building Owner s Responsibilities for Fire Safety Equipment

60cm Chimney Extractor

KRISHNAMURTI FOUNDATION TRUST FIRE SAFETY POLICY. Last Review Date 30 June Next review date 30 August Health and Safety Officer

PREMISES FIRE SAFETY LOGBOOK

Fire Safety Plan FOR. Business/Property Name: Address: Phone Number: Occupancy Classification. Approved by Fire Inspector: Date:

INSTALLATION AND USER S MANUAL COOKER HOOD RS-600/A-S

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NEW BUILDINGS

Fire Risk Assessment 2017

NFPA 96, 2017 REVIEW SUMMARY

Fire Risk Assessment

Loss Prevention Standards

Fire Risk Assessment. ABC Car Workshop. Prepared for. Redacted

Fire Safety Guidance 2. Health & Safety 4. The following guidance is intended to supplement the QMUL procedures.

Mobile Vendors Bulletin

REQUIREMENTS FOR EVENTS AND TEMPORARY STANDS AT FAIRS AND SHOWS

FIRE SAFETY PRACTICES AND PROCEDURES

Builders Risk - Fire Prevention Inspection Checklist

"Let's provide you with a superior User Experience delivering Ease-of-Mind."

Tents and Temporary Membrane Structures Permit Procedure

Risk Control Recommendations for fire safety in commercial kitchens

Standards and third party certification

BWT6.3GL Cooker Hood 60 cm Glass chimney hood

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NO 68 (ENGLISH AND PHILOSOPHY)

TENTS AND TEMPORARY MEMBRANE STRUCTURES PERMIT PROCEDURE

Fraternity, Sorority and Dormitory Buildings R-2 Fire and Life Safety Standards Inspection Form Fire Code of New York State (19 NYCRR Part 1225.

OWNER S MANUAL FOR ELECTRIC FRYERS. Model Numbers PARAFRYER (240V) ELECTRIC FRYER

BWTC6510GL Cooker Hood 60 cm Glass cooker hood in stainless steel. BWTC9510GL Cooker Hood 90 cm Glass cooker hood in stainless steel

Automatic Sprinkler Systems Care and Maintenance

Fire Risk Assessment Keys Meadow Primary School

Chesterfield Borough Council

Sandwell Valley School and Sandwell Community Care Trust Training. 150 Birmingham Road, West Bromwich, B70 6QT

FIRE RISK ASSESSMENT Retirement Housing (Independent Living) (v3.november 2016)

Web:

STOCKLINCH VILLAGE HALL FIRE RISK ASSESSMENT

Fire Risk Assessment Safety Checklist

Fire Prevention Plan for St. Barbara Hall 3904 Winding Way

The following information is presented as a primer to inspect commercial cooking. We will deal with the form in parts as shown below.

Personal Protection Systems (PPS)

The heat is on. Chris Auger explains developments that led BAFE to develop its SP206 scheme, designed to promote safety in commercial kitchens

Is the address of your property clearly visible and marked in large numbers that can be easily seen from the street?

H&S Forum. Fire Safety Policy Glascote Academy

Allfire Site No. a division of Allsaved Ltd. Fire Safety Log Book. Premises Address: Responsible Person:

fire risk assessment For use by landlords of small premises Premises Address

MODEL: JRSVH SERIES JEAN S RESTAURANT SUPPLY 426 SOUTH STAPLES CORPUS CHRISTI, TEXAS PH: (361)

BT16.4SS-HK BT19.4SS-HK Cooker Hood

Byker Various post codes. Your Homes Newcastle Health and Safety (fire) Officer Date of Fire Risk Assessment 18 th February nd October 2014

EN Instruction on mounting and use

Statutory Compliance Checklist

Sheetz Inc. Fire Protection Service Guidelines

Arbour House. Fire Policy and Procedures

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE EMERGENCY PLAN

FIRE SAFETY POLICY. This policy refers to both Wellington Senior School and Wellington Prep School

FOOD PREPARATION WITHIN EXHIBITS

FIRE RISK ASSESSMENT CHECKLIST

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry

APPENDIX P FAT, OIL AND GREASE MANAGEMENT ISSUE A AUGUST 17. Appendix P

A basic guide to... Fire Safety for Scout Premises

User and maintenance manual

Fire Prevention Plan for Bellarmine Parish Center 3832 Ledgewood Avenue

Title: Room-sealed fanned draught flue systems concealed within voids

BFR6 / BFR9 Rangehood

Fire Safety Management Audit Specification August 2017

Stillwater Area Community Services Center Inc.

NFPA 101 Life Safety Code Culture change 2012

UCL PRINCIPAL CONTRACTOR SITE FIRE SAFETY RISK REVIEW & MITIGATION MEASURES

Making sense of risk Risk engineering. Metalworking operations

Transcription:

PREVENTING COOKING FIRES Real Estate Bulletin Frazer Argyros-Farrell UK Real Estate Practice Lead RSA Risk Consulting MARCH 2018

2/8 CONTENT Introduction... 3 Cooking... 4 Extraction and Ductwork... 5 New Installations... 7 Further Advice... 8

3/8 INTRODUCTION Cooking fires are incredibly common and often lead to large or major fires. In some instances these fires lead to total loss of the building and businesses within. One of the main issues is that a fire within cooking equipment can ignite any grease and fat deposits within cooker hoods and extraction ductwork. As the ductwork passes through the building it can spread the fire throughout. Ductwork fires can also be difficult to extinguish due to access issues. This bulletin offers practical advice and guidance on preventing the risk of cooking fires.

4/8 COOKING Ensure that cooking oils are regularly replaced oils full of debris ignite more easily than clean cooking oils Annual maintenance of cooking equipment is essential - this should include ensuring that over temperature thermostats and auto-shut offs are fully operational Portable fire extinguishers should be readily available at all times they should not be obstructed. Class F fire extinguishers are recommended where deep fat fryers are used. Kitchen staff should be trained in the use of portable fire extinguishers Where suppression systems are installed staff should be trained/instructed on how to manually activate the system Ensure nozzles are correctly aligned and protective caps are inspected/maintained to prevent becoming blocked with grease/fat Staff should be fully aware of the shutoff procedures for gas and/or electricity. A manual shut-off should be readily available and staff should be aware of its location. The manual shut-off should be clearly signed and on the exit route There should be no unnecessary combustible storage around cooking equipment this includes cleaning cloths. No combustible items should be placed on top of cooking equipment at any time

5/8 EXTRACTION AND DUCTWORK It is highly recommended that where deep fat frying takes place that an automatic suppression system is installed. The systems should be installed within the cooker hood and the ductwork. The system should be designed and installed to BS EN 15004 and BS 7273-2:1992. Installers should preferably be BAFE registered Where installed the suppression system should be routinely maintained at least every six months, to ensure the system is fully operational. The system should be maintained in line with the manufacturer s requirements and BS EN 15004 The canopy, grease traps and mesh style filters should be cleaned daily, and baffle type filters cleaned weekly - most filters can usually be cleaned in a dishwasher. Baffle type filters are preferred A programme of deep cleaning of ductwork and cooker hoods needs to be in place, and in a written and formalised programme that is auditable: Cleaning should be in line with BESA TR19 Guidelines - Good Practice Internal Cleanliness of Ventilation Systems Section 7 Frequency of ductwork cleaning is dependent on what is being cooked, how it is being cooked and the volume and frequency of cooking. Obviously the more the system is used the more often it will need to be cleaned. TR19 makes the following recommendations: Usage Usage per Day Frequency of Cleaning Heavy 12 16 hours 3 monthly Moderate 6 13 hours 6 monthly Light 2 6 hours 12 monthly Pay particular attention to known hazard areas, such as areas where excessive grease accumulates Photographs of ductwork before and after cleaning should be taken and held on file Residue built up pre and post clean to be ascertained by the cleaning contractor to support future cleaning regimes Ensure that adequate time is given to ductwork maintenance during busy periods

6/8 EXTRACTION AND DUCTWORK Prohibit hot-work (cutting and welding) on installed extraction ductwork. Where hotwork is unavoidable, remove ductwork as required to complete work off the premises or in a suitable workshop. Ensure that permits are issued for all hot works In older systems, access panels may not be present. Where possible access hatches/ panels should be installed. The hot work guidance above should be followed When using cleaning contractors, they should be suitably inducted to ensure they understand site safety rules and procedures. Their performance should be closely monitored. Contractors should be third party approved by a recognised body such as LPCB s LPS2084

7/8 NEW INSTALLATIONS Avoid combustible construction (including roof void access platforms) where cooking equipment and associated extraction ducts are used Route flues and extract ducts through non-combustible construction. Where combustible construction is unavoidable, adequately separate extraction ducts from combustible construction with noncombustible insulating collars, at least 15cm thick Provide dust extracts with easily removable panels/inspection hatches every three metres. This will ensure adequate cleaning and inspection is possible Where possible ductwork should be installed in straight runs to avoid angles where fats and grease can collect. Where angles are needed they should be a maximum of 45

For further advice contact your underwriter or: Frazer Argyros-Farrell, BSc (Hons) AIFireE MIFSM UK Real Estate Practice Leader RSA Risk Consulting RSA Insurance 15th Floor, 20 Fenchurch Street, London, EC3M 3AU Mobile: +44 (0) 7769 238393 Email: frazer.argyros-farrell@uk.rsagroup.com rsagroup.com This document is provided to customers for information purposes only and does not form any part of any policy which is in place between the customer and RSA. The information set out constitutes a set of general guidelines and should not be construed or relied upon as specialist advice. RSA does not guarantee that all hazards and exposures relating to the subject matter of this document are covered. Therefore RSA accepts no responsibility towards any person relying upon the Risk Control Bulletin nor accepts any liability whatsoever for the accuracy of data supplied by another party or the consequences of reliance upon it. References: RSA Hot Work Risk Control Guide v2 - RCG003(E) The LPCB standard LPS2084 can be found here: http://www.riscauthority.co.uk/about/latest-news_detail.kitchen-extract-ductwork-cleaning-standard.html UKC05133