Benchtop Test Chambers. Temperature and Humidity

Similar documents
Benchtop Test Chambers Temperature and Humidity

The best test chambers...

Temperature Cycling Chambers Global-N Series

Advanced Test Equipment Rentals ATEC (2832) Temperature Cycling Chambers Global-N Series

Walk-in Test Chambers. Panelized & Solid Construction

The best test chambers...

Platinous. temperature. and humidity. chambers. Top Quality Design. With an Easy-to-use. Touch-Screen. Programmer

Walk-in Test Chambers Panelized & Solid Construction

Quality is more than a word

Faster Temperature (& Humidity) Chamber

Bench-Top Type Temperature (& Humidity) Chamber

FAST CHANGE RATE AND DRIVE-IN CHAMBERS FOR AUTOMOTIVE TESTING. by ESPEC North America Inc

Compact Ultra Low Temperature Chamber

Utility. Small size & light weight. Compact design with high performance SH-661. Select your optimum chamber from a full variation

Compact design for personal use Ready to network with your computer.

Thermal Shock Chamber TSE 11

Benchtop & Compact Test Chambers

Faster Temperature (& Humidity) Chamber

Environmental Stress Chamber AR series

VWR symphony CO 2 INCUBATORS


Elmatik AS, Türi 9, Tallinn Estonia tel tel fax

Z-Plus Series Temperature/Humidity

Utility. Improved functionality and ease-of-use for bias testing. The chamber interior is formed for easier specimen loading

NEW! TSX Series high-performance undercounter refrigerators

Stability & Shelf Life

Z-Plus. Temperature/Humidity Chambers.

NEW! TSX Series high-performance undercounter refrigerators

NEW! Thermo Scientific Revco PLUS Ultra-Low Temperature Upright Freezers. Maximizing Critical Sample Protection and Storage

Remote Conditioners. RC-Series. ZPRC Series

Remote Conditioners. RC-Series. ZPRC Series

Industrial Freezer Sales A division of IDS 5311 Derry Avenue Building D Agoura Hills CA Phone (818) Fax (818)

Bench-Top Type Temperature (& Humidity) Chamber

Environmental.

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

NEW! Thermo Scientific Revco PLUS Ultra-Low Temperature Upright Freezers. Maximizing Critical Sample Protection and Storage

MINI BENCH TOP CHAMBER MODEL: MI-80-A-H

Liquid to Liquid Thermal Shock Chamber TSB 21 TSB 51

Z-Plus Temperature/Humidity Chambers

halt & hass systems

Mitigating Risk of Battery Testing in Environmental Chambers. Mark Chrusciel & Wayne Diener Cincinnati Sub-Zero

Altitude Chambers.

Performance. TCC-150 provides uniform temperature load, and highlyrepeatable temperature change rate. Conformity to JEDEC JESD22-A104-B standard test

FREE ZERS LABORATORY FREEZERS -30 O C. i.series TM Horizon Series TM

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Environmental Chambers

NEW! Thermo Scientific Revco PLUS -86 C Freezers. Protecting Your Life s Work

Stability Chambers & Rooms

ISO-9001:2008 FURNACES CATALOG. Phone: Fax: Web:

ENVIRONMENT FRIENDLY CLIMATIC CHAMBER

Espec Chamber User Manual Hydgechalkoles Wordpress

Thermo Scientific Precision Ovens

Environmental simulation chamber for complex alternating climate profiles

GENERAL DESCRIPTION. LRE.com 1. CHAMBER

Environmental.

Thermo Scientific Heratherm Microbiological Incubators. safe easy efficient

Isotemp. Improve the productivity of your laboratory with accurate, efficient temperature control products from Fisher Scientific.

HettCube INCUBATORS SUSTAINABLE. ERGONOMIC. HIGH QUALITY. INCUBATOR. Find out more by visiting:

Protection, safety, reliability. And more.

Industrial Freezers &

Setting the New Standard in Chiller Technology ±0.1 C ZEROPOINT CHILLER SERIES

Thermo Scientific Heratherm Heating and Drying Ovens. efficient safe easy. Part of Thermo Fisher Scientific

Environmental Chambers. 2-Door & 3-Door Extra Large Capacity

Freezers. Laboratory & Plasma. i.series Horizon Series. Distinctly. Innovation can be beautiful.

Environmental Chambers Series: reach-in & benchtop capacities

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

Battery Charge/Discharge Test System Integrated with Temperature Chamber

Thermo Scientific Heratherm Microbiological Incubators. safe. Part of Thermo Fisher Scientific

Thermo Scientific 1300 Series A2

Series of all-purpose physical and chemical environmental cabinets meeting the diverse needs of laboratories and research facilities.

Cardinal Health Ultra-Low Freezers. Protecting your samples requiring ultra-low storage

Controlled Environment Equipment Solutions for the Lab

Highly Accelerated Stress Test System (HAST Chamber)

TCC-34. Features: TISSUE CULTURE

FORCED-AIR LABORATORY OVENS

Ultra-Low. Temperature. Freezers. Advantage Series. Basic Series. Microprocessor Control. Solid-State Electronic Control

Installation Operation Maintenance Manual Z-Series

Thermal Management INDEX. Management. Thermal TM-1

Premium Efficient OIL-FREE Compressors

Model KMF 115 Constant climate chambers with expanded temperature / humidity range

Methods of Desiccation

SPC-56 SHORT PLANT.

NEW INTELLIGENT AIR TECHNOLOGY

Utility. High performance by special glass. Supports high-temperature, high-humidity testing

Blanket and Solution Warming Cabinets

BIOMEDICAL FREEZERS ULTRA LOW TEMPERATURE FREEZERS LOW TEMPERATURE FREEZERS

Constant climate chambers

Thermo Scientific VersaCool Refrigerated Circulating Bath. experience the benefits. of going headless

Reach-In. PLanT GROWTh. Reach-In

"N-Width" Reach-In Refrigerator-Freezer Models/Self-Contained. Project Quantity Item # Model Specified: CSI Section 11400

Ultra-Low Temperature Chest Freezers

Version 7 1/ LX

Freeze Dry Systems and Accessories

Thermo Scientific Cryopreservation Storage Equipment

Thermo Scientific Revco Value Freezers and Refrigerators. General Purpose Explosion Proof Flammable Material Chromatography

Upright Freezers. Laboratory Plasma. TrueBlue. Reliability & Support. i.series Horizon Series

Walk in Steam Curing Chamber for Concrete Application. Detailed Working Specifications

Constant climate chambers

REVCO MECHANICAL CRYOGENIC FREEZER

VWR Laboratory Refrigerators and Freezers

Transcription:

Benchtop Test Chambers Temperature and Humidity

Compact chambers with extended testing ranges ESPEC's Criterion benchtop chambers offer two sizes and a variety of testing ranges. With many options, they can be confi gured to accommodate your specifi c requirements. Their narrow footprint saves valuable lab space. 2

Benchtop Features Models save valuable lab space ESPEC introduces our expanded Criterion Series. With a narrower footprint and increased performance, these test chambers provide an economical and space-saving solution for cramped labs needing to do a variety of temperature (and humidity) testing. Size Comparison 1.5 cu. ft. 4 cu. ft. 24 All of the Criterion models have a 19.5 inch wide interior, which is 3.5 inches more than traditional benchtops, yet the exterior is 20% narrower. The four cubic foot models have the largest workspace found in a benchtop unit, while maintaining the smallest exterior footprint. For additional space savings, the refrigeration system ventilates out the top, and utility connections are on the sides, thus allowing installation directly against a wall. With the electrical system behind the hinged control panel, minimal space allowance is required on the sides, as well. Big chamber performance The extended temperature ranges of the Criterion series make testing at extreme conditions possible without buying a larger, stand-alone chamber. Units are available that go as cold as -70 C. The four cubic foot models also offer a choice of humidity control. With a range from 10 to 95%, you can maximize your testing options. A low humidity system can extend this range even farther. (See humidity chart on page 7 for details.) 12 The Criterion series has two chamber sizes: 1.5 and 4 cubic feet. The interior width for both sizes is 19.5 inches. The exterior footprint for both sizes is the same, just 30.25" x 33.5". BTZ & BTX all models BTU & BTL all models 11 19.5 19.5 Temperature Range Comparison ( C) -50 0 50 100 150 200-70 180-20 180 The BTZ & BTX models have extended cold temperature ranges without requiring liquid nitrogen. The BTU & BTL still offer sub-freezing testing capability. 15 Faster temperature changes The Criterion series can cycle temperatures at rates up to 5 C/minute without requiring liquid nitrogen. Signifi cant test time can be saved, as well as creating added thermal stress on your samples. Performance Comparison 180 150 100 50 BTZ-175: 5 C/m BTZ-133: 3 C/m To demonstrate performance, ESPEC uses the international standard IEC 60068 3-5 measured at the supply air. Temperature cycles are run from hot to cold extremes, and the middle 80% of the transition is timed to determine performance. Your actual cycling results will vary depending on methodology, including the start and end temperatures, and the amount of samples loaded. 0-50 -70-100 0 30 60 90 120 150 180 min. The Criterion chambers respond quickly to setpoint changes. The BTZ-175 can save 30 minutes or more per cycle. 3

Benchtop Features Space-saving design An innovative new layout of system components helps make Criterion chambers have the smallest footprint. Keeping the refrigeration compressors and blower fan to the back of the chamber also reduces noise to the room. Useful safety features To protect from the risk of overheating, there are three levels of protection: 1. Settable within the programmer 2. An independent settable monitor 3. A thermal fuse In addition, a specimen power terminal allows the user to safely operate powered equipment inside or with the chamber. If the chamber is shut down, the interlocked device will also be shut down. Highly reliable operation The Criterion platform has been reengineered from the ground-up to be consistent, reliable, and easy to maintain. ESPEC stands behind the chambers with a comprehensive one-year parts and on-site labor warranty. Quality cabinet construction ESPEC is meticulous about making a chamber that is more than just functional. Stainless steel exterior and interior Rounded corners for easy cleaning Full thermal break around doorframe and door Rotating door latch is easy and secure Dual-layer insulation of fi berglass and expanded foam for thermal integrity One 2" (50mm) diameter cable port on the left, with an impervious, flexible silicone plug Easy lift-off service panels Floor drain and drip-tray under the doorframe The chamber's fan continuously circulates conditioned air from the test area to the plenum (to the right of the test area), where the heaters, cooling coil, and humidity inlet are located. (BTX-475 model shown). A nonmetallic thermal break around the door and doorframe stops transfer of heat/ cold to the exterior (BTZ-133 model shown). 4

Instrumentation Watlow F4T controller The F4T is the newest programmer/controller from Watlow, now with an easy to use touch-screen. It stores up to 40 different test profiles. Programming steptypes available are: ramp, soak, jump/repeat, auto-start, and end. The F4T includes an Ethernet interface with familiar Modbus protocol. Optional software is available for full remote management and datalogging capability. One event relay with external output terminal is included for activating other equipment during operation. Options Cabinet Options Humidity Options Roll-around cart with storage cabinet (suitable for chart recorder placement) Cable ports: 2", 4", or 6" diameter (50, 100, or 150mm). One 2" port is standard on the left wall. Adjustable stainless-steel shelving Heated viewing window with interior light, 6"x6" (6"x12" for 4 cubic foot models) Solid-state humidity sensor in place of wet-bulb External water supply tank with recirculating capability Water supply tank system as a roll-around cart for the unit Water filter (de-ionizing type) Extended low humidity range to 5 C/15% (see chart, page 7) Instrumentation Options Cart Cable port Window Operational Options Web Controller for network access via web browser RS-485 or RS-232 serial interface Chino paperless recorders with Ethernet and email alarms Honeywell circular-chart recorders Control sensor outputs for customer use Paperless recorder Liquid nitrogen (LN 2 ) injection boost for faster cooling Emergency stop 'mushroom' button Safety features for testing lithium ion batteries or other potentially volatile products. ESPEC humidity system expertise Controlling humidity in a small environmental chamber can be especially challenging. ESPEC's expertise in humidity control brings intelligent design that is carefully integrated into the BTL-433 & BTX-475. The humidity subsystems are designed for reliability, convenience, and performance: An external steam generator allows expanded range and is easy to maintain. A separate de-humidifi cation coil improves low humidity control and range. The wet-bulb humidity sensor is an accurate primary measurement method. It is economical, easy to maintain, and reliable because it has no risk of failure due to over-saturation. Direct water supply connection is standard, with options for water filtering and external tank. Steam generator removes for easy cleaning 5

SPECIFICATIONS - 1.5 CU. FT. MODELS Model BTZ-133 BTZ-175 BTZ-175E BTU-133 Temperature Range -70 to 180 C (-94 to 354 F) -20 to 180 C (-4 to 354 F) Change Rate (per IEC 60068 3-5) 3.5 C/m heat-up 3 C/m cool-down 5 C/m heat-up 5 C/m cool-down 2 C/m heat-up 1.6 C/m cool-down Temperature Fluctuation ± 0.5 C per IEC 60068 3-5 Temperature Gradient ± 1.5 C (up to 100 C) per IEC 60068 3-6 Live Load Capacity 160 W to -40 C 300 W to -40 C 200 W to 0 C Interior Volume 1.5 cu. ft (42 L) Interior (W x D x H) Exterior (W x D x H) 19.6" x 11" x 12" (500 x 280 x 300 mm) 30.25" x 33.5" x 34" (770 x 850 x 865 mm) Heaters 500 W 1000 W 500 W Refrigeration 1/3-hp x2 (cascade) 3/4-hp x2 (cascade) 1/3-hp x1 (single-stage) Air Circulation 100 cu. ft./min. (2.8 m 3 /min.) Site Requirements Electrical Supply 115V 1ph 60Hz 20A 208/230V 1ph 60Hz 20A 230V 1ph 50Hz 20A 115V 1ph 60Hz 20A Weight 300 lbs. (136 kg) 400 lbs. (181 kg) 275 lbs. (125 kg) Sound Level 65 dba (1 meter away from door) Heat to Room 5,100 BTU/Hr 9,000 BTU/Hr 3,600 BTU/Hr Gravity Drain Room Temperature 3/8" NPT Performance assured when room temp. is steady, 18 to 27 C (65 to 80 F) Chart shows example of heating and cooling ramps during IEC 60068 3-5 qualifi cation (see page 3). 180 150 100 BTZ-133: 3 C/m BTZ-175(E): 5 C/m BTU-133: 1.6 C/m 50 0-35 -50-70 -100 0 60 120 180 240 300 350 min. 1.5 cu. ft. (this page) 4 cu. ft. (next page) Accessories included with each chamber: Silicone plug for standard cable port Power cable with plug (115V is NEMA 5-20, 208/230V is NEMA 6-20) Box of wet-bulb wicks (BTL/BTX) Operation & programming manuals, parts list & schematics (via download) 6

SPECIFICATIONS - 4 CU. FT. MODELS Model BTL-433 BTX-475 BTZ-475 BTU-433 Temperature Range -20 to 180 C (-4 to 354 F) -70 to 180 C (-94 to 354 F) -20 to 180 C (-4 to 354 F) Change Rate (per IEC 60068 3-5) 1.5 C/m heat-up 1.2 C/m cool-down 2.75 C/m heat-up 2.5 C/m cool-down 1.5 C/m heat-up 1.2 C/m cool-down Temperature Fluctuation ± 0.5 C, per IEC 60068 3-5 Temperature Gradient ± 1.5 C (up to 100 C), per IEC 60068 3-6 Live Load Capacity 160 W to 0 C 300 W to -40 C 160 W to 0 C Humidity Range 10 to 95% RH, per chart below - Humidity Fluctuation ±5% RH per IEC 60068 3-5 except measured in supply air - Interior Volume 4 cu. ft (110 L) Interior (W x D x H) Exterior (W x D x H) 19.6" x 15" x 23.6" (500 x 380 x 600 mm) 30.25" x 33.5" x 46" (770 x 850 x 1170 mm) Heaters 500 W 1000 W 500 W Refrigeration 1/3-hp x1 (single-stage) 3/4-hp x2 (cascade) 1/3-hp x1 (single-stage) Air Circulation 200 cu. ft./min. (5.6 m 3 /min.) Site Requirements Power Supply 115V 1ph 60Hz, 20A 208/230V 1ph 60Hz 20A 115V 1ph 60Hz, 20A Weight 325 lbs. (147 kg) 550 lbs. (250 kg) 325 lbs. (147 kg) Sound Level 65 dba (1 meter away from door) Heat to Room 3,600 BTU/Hr 9,000 BTU/Hr 3,600 BTU/Hr Gravity Drain 3/8" NPT Humidity Water Supply Supply: 3/8" NPT, 30-50 psig Typical usage: 0.5 gallon/day Purity required: 0.2 μs/cm to 10 μs/cm - Room Temperature Performance assured when room temp. is steady, 18 to 27 C (65 to 80 F) Chart shows example of heating and cooling ramps during IEC 60068 3-5 qualifi cation (see page 3). Controlled humidity range for BTL-433 & BTX-475 models (without live load). Optional low humidity range shown in red. 180 150 BTL / BTU-433: 1.2 C/m BTX / BTZ-475: 2.5 C/m 95 80 100 50 0-20 -50-70 -100 0 60 120 180 240 300 350 %RH 60 40 20 5 / 15% 20 40 Temp. in C 60 80 85 7

www.espec.com sales@espec.com 4141 Central Parkway, Hudsonville, MI 49426, U.S.A. Tel: 1-616-896-6100 ESPEC EUROPE GmbH Germany www.espec.de info@espec.de Tel: 49-89-1893-9630 ESPEC ENVIRONMENTAL EQUIPMENT (SHANGHAI) CO., LTD. China www.espec.cn Tel :86-21-51036677 ESPEC SOUTH EAST ASIA SDN. BHD. Malaysia www.espec.com.my Tel: 60-3-8945-1377 ESPEC ENGINEERING (THAILAND) CO. LTD. Thailand Tel: 66-3-810-9353 www.espec.co.jp/english 3-5-6, Tenjinbashi, Kita-ku, Osaka 530-8550, Japan Tel: 81-6-6358-4741 DANGER Not for use with specimens which are explosive or fl ammable, or which contain such substances. To do so could be hazardous, as this may lead to fi re or an explosion. BTL-BTZ CRITERION (A) May 2017