KE2 EvaporatorEfficiency Installation Manual

Similar documents
KE2 Evaporator. Installation Instructions. 01/13 Rev. A ENTER BACK. TM thermsolutions KE2 EvaporatorEfficiency

KE2 EvaporatorEfficiency Installation Instructions

KE2 EvaporatorEfficiency Quick Start Guide

Contactor Panel with KE2 Evap for Rack Efficiency (pn21281 & 21282) Quick Start Guide

KE2 EvaporatorEfficiency Installation Instructions

EVAPORATOR EFFICIENCY

RDT EcoSmart Quick Start Guide

KE2 EvaporatorEfficiency Quick Start Guide

KE2 EvaporatorEfficiency Installation Instructions

Application and Installation Bulletin for Master-Bilt Refrigeration Superheat Controller Kit Assembly(A ), 120/208/240/1/60, R404A, LT/MT APPS

KE2 EvapOEM pn21231 Quick Start Guide

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

Subcooling is defined as the point at which liquid is cooled below it s condensing temperature. Example: Refrigerant R404A

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC.

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS

technical bulletin Control Link RSC Installation Instructions

Unit Coolers. Installation and Operations Manual

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

INSTALLATION INSTRUCTIONS FOR 7330C740 FLUSH MOUNT CEILING ASSEMBLY

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

Warm Case Troubleshooting Guide 9/18/2014

Tempered Water Logic Control OPERATION l TROUBLE SHOOTING

KE2 EvaporatorEfficiency Theory of Operation

Hoffman Controls 759-ECM. Installation & Operating Instructions. Introduction. Installation. Pre-Installation Information/ Instruction

HP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS

MR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack

Installation and Operation Manual

RSMSD Technical Guide

Installation and Operation Manual

INSTALLATION INSTRUCTIONS

Daikin ENVi Thermostat installation overview

B-40/B-41 Modulating Temperature Controller

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

INSTALLATION INSTRUCTIONS

ThermoSaver TM Hot Gas Defrost System

SAFETY INFORMATION AND WARNINGS

Installation and Operation Manual

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

Rev 7 06-APR MultiFlex Condensing Unit Board (CUB-II and CUB-TD) Installation and Operation Manual

PS SERIES PARALLEL RACK SYSTEM GLYCOL CHILLER START UP GUIDE 11/03/2015 Rev 00

Water Source Heat Pump Module Technical Guide

ThermoSaver TM Hot Gas Defrost System

Duct and Rough Service Carbon Monoxide Sensor

INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

Container Refrigeration

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

MR3CCUHV Temperature/Defrost Control

Bulletin , March Electric Hot Gas Bypass Valves

Emerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

Installation and Operation Manual

IF79 CAUTION CONTENTS YOUR THERMOSTAT REPLACES 1 PREPARATIONS. Installation Instructions for. Heating & Air Conditioning

Condensing Unit Installation and Operating Instructions

CONTENTS A FEW WORDS ABOUT YOUR NEW AIR CONDITIONING UNIT 2 ELECTRICAL DATA 2 OPERATING INSTRUCTIONS 4

INSTALLATION INSTRUCTIONS FOR 6797A737 HEAT PUMP FLUSH MOUNT CEILING PLENUM

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

AIR-COOLED CONDENSING UNIT UNITS PRODUCED AFTER JANUARY, 1996 INDEX SCHEMATIC DIAGRAM FIG. NO.

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

RSMV Technical Guide

SmartVap Air / Electric Defrost Control System

Condensing Unit Installation and Operating Instructions

CommStat 4 Controller

INSTALLATION INSTRUCTIONS FOR 7370A736 FLUSH MOUNT CEILING PLENUM

GeneSys Air-Cooled Screw Compressor Chiller

Heat Transfer Products, Inc. 120 Braley Road East Freetown, MA The first totally integrated multiple boiler management control.

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits

OWNER S MANUAL. Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750. Proudly Made in the USA.

BASIC HEAT PUMP THEORY By: Lloyd A. Mullen By: Lloyd G. Williams Service Department, York Division, Borg-Warner Corporation

ACT2-CS Convenience Store Controller

RC-101 Heat Pump Real Time Pricing System 2 Stage Heat / 1 Stage Cool

Owners Manual Refrigerated Air Dryer MHT SERIES

EC3-X33 Stand-alone Superheat Controller Technical Data

R.A.S.E.R.S System. Installation Guide

PS SERIES PARALLEL RACK SYSTEM START UP GUIDE

Low Profile Unit Coolers

208/230/1/60 5/8 5/8 5/8 5/8 5/8 20 CLIMATUFF /230/1/

Service Manual. ETL Blast Chiller Series

SERVICE NUMBER: SERV-351

DIMENS. MIN TYPICAL MAX A 71.0 (2.795) 71.0 (2.795) 71.8 (2.826) B 29.0 (1.141) 29.0 (1.141) 29.8 (1.173)

CU 300 GRUNDFOS INSTRUCTIONS. Installation and operating instructions

Operation & Maintenance

MODEL MW200 MODEL MW600 AIR DRYER

Master Controller 3.2 Reverse Cycle Defrost System

MICROtrac MICROPROCESSOR BASED WATER TREATMENT CONTROLLER. Installation and Operation Manual REV. L

SM/SV-Space Master Unit Coolers (E R.0)

EQUIPMENT PRE-STARTUP AND STARTUP CHECKLIST TEL NO: ORDER NO: CONTRACT NO:

1F Non-programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

CONDENSING UNITS-AIR SUBMITTED BY : Poppy Hudson PROJECT : Brooks Landing REV DATE : 07 Dec 2017 ORDER # : A00

MS4PMUHVT Multi-Stage Electronic Temperature Control with Relay Pack

KR Electrical Defrost Unit Coolers (PN E108318_E)

Transcription:

Q.1.3 January 01 Installation Manual This reference should remain on site with the installed KE Evaporator Efficiency controller. A D I C E B J F L M N G K H Parts List The following parts are included in the KE Evaporator Efficiency (KE Evap) controller kits: Kit # 0178 with 10/08-40 VAC controller - OR Kit #0* with Beacon I or II replacement controller A (1) Window sticker B (1) Warranty card C (1) Air sensor mount D (1) High voltage safety shield Supplies List The KE Evap is supplied with all of the accessories required for the controller to work, however, standard truck stock items will also be required to install the controller. To simplify the installation, a list of items has been provided. Conduit to go between the controller and the evaporator () Conduit connectors (straight or elbow as required) (11) High voltage wires matched to the load of the heaters, fans, liquid line solenoid, alarm (if used), and the controller. E (4) 3-position screw down terminals (for power in, transducer (8) Spade Connectors matched to the gauge of high voltage wires F ( ) Voltage jumpers (one already on back of KE Evap) Wire labeling (numbers, colors, etc.) G (1 ) 5-position screw down terminal (for EEV) H (8) -position screw down terminals (for sensors and digital input, analog output) Additional wire ties I J K L and 3A relays) (4) wire ties (rated for low temp) (5) Self-tapping screws (4) 90 degree quick disconnects (1) fine thread machine screw with lock washer M () course thread screws N () 10 temperature sensors part# 0199 * Beacon kit includes an extra temperature sensor and pressure transducer and cable. Copyright 011 KE Therm Solutions, Washington, Missouri 63090 18 gauge twisted shielded pair (if extending sensor wires) Foam insulation if running wires outside the space. Silicone (for sealing any box penetrations)

Page Arriving at the Jobsite When arriving at any jobsite, it is good practice to verify the correct operation of the system. Even systems running for a considerable amount of time without a service call may not be running properly. Inspect the coil to see the current frost pattern. If the unit has not recently performed a defrost, look for the heaviest area of frost. This will be used to locate the coil sensor. Remove the evaporator end covers. Installers should account for a full system diagnostic in the installation estimate for the controller. Although it may seem unnecessary, identifying system issues before the controller is installed will save time overall. It will also allow the controller to provide the highest energy savings. Verify the system is running correctly. Taking several measurements will help determine the current health of the system. Using the diagram below, fill in the necessary information. Two of the most critical indicators of system health are the superheat and subcooling. Superheat - Superheat is the most overlooked inefficiency in existing systems. Typically the superheat on a TEV is set when there is not product in the controlled space, if it is set at all. When applying the controller to an existing system with a mechanical expansion valve, the superheat should be between 6-8 degrees for low temperature applications and 8-10 degrees for medium temperature. Subcooling - There should be a solid column of liquid at the inlet of the valve. This can be verified by looking at the sight glass, however, the proper method is to measure the subcooling of the liquid entering the valve. Verify Temperature Difference A typical Temperature Difference (TD) between the coil temperature and the air temperature is between 5 and 15 F. An insufficient TD, between the coil and air temperature, indicates a system issue that needs to be addressed before installing the KE Evap Efficiency. Refrigerant Trouble Shooting Diagram Cold Air Suction Pressure PSI Suction Temp F (evaporator outlet) Cold Vapor Evaporator Temp Difference (TD) (return air minus coil temp) F Coldest point in evap F Liquid/Vapor Mix Saturation Temp F (calculated from Suct. Pressure) Restrictor, TEV or EEV Saturation Temp F (from receiver pressure) Superheat Hot Vapor Liquid Temp at Valve F Condenser Discharge Pressure PSI Warm Liquid Subcooling Compressor Warm Air AMPS

TM thermsolutions ENTER BACK TM thermsolutions TM thermsolutions ENTER TM thermsolutions BACK ENTER BACK Page 3 1 Determining Location The controller is designed to be as versatile as possible. The location should be discussed with the end users to determine if they have a preference. It is designed so it can be installed inside or outside the controlled space. 1 On the evaporator The controller can also be located at the condenser, but should not be installed outdoors without an enclosure to protect it from sunlight and moisture (must be within operating range -40 F to 140 F) On the wall At the entrance Cut a length of conduit to go from the controller to the evaporator Measure the distance between the controller and evaporator to account for the extra length necessary to properly route conduit.? Determine the number of wires to go to the controller. Controller power (3 wires) Fan control ( wires) Defrost (heater) control ( wires) Liquid line solenoid ( wires) Alarm relay ( wires) Note: Install in accordance with local wiring codes. KE Therm does not accept responsibility for incorrect or unsafe wiring. Evaporator ENTER BACK Cut wires to length Once the number of wire is determined, cut the wires to length. The wire should be long enough to account for the necessary connections in the controller and evaporator. Using different colored wires, (blue - fan, orange - heaters, yellow - solenoid, purple - alarm) will simplify the installation and troubleshooting. If only a single color is available, both ends of the wires should be labeled with a matching number. This will save time when wiring the evaporator. 3 3

Page 4 Determine the current draw of the unit. 4 Using the nameplate to determine the Amp rating of the unit. This information should be used to select the proper sized wire. It should also be used to verify the unit does not exceed the relay rating on the KE Evaporator Efficiency controller. 4 Preparing conduit 5 Feed the wires through the conduit. 5 The conduit connectors can be added at this time. Determine if a straight or 90 degree connector is most appropriate for the installation, and attach to the conduit. Securely connect one end of the conduit to the controller. Wiring the controller 6 Locate the second Voltage Jumper in the accessory kit. 6 It is a position plug with red jumper already installed. Plug 1 jumper on the center pins for 08-40V power and jumpers on the outer pins for 10V power. Power is not connected to Voltage selector, it is a selector only. Power for the controller is connected to the Power In location using a 3 position connector. 10V Controller Power 7 Strip the end of the wires used to provide power to the controller Locate a 3 position terminal in the accessories kit. Fasten to the 3 position pluggable connector*. Plug into the board as indicated in Wiring Schematic. *All terminal screws should be tightened to 5 ft-lbs. 7 08-40V

Page 5 Fan Relay 8 Strip the end of the wires used for fan control. 8 Locate female spade connectors in the accessories kit. Crimp on the female spade connectors. Plug the connectors to the COM and NO positions of the Fan Relay. Confirm combined fan motor load is not over 10 amps Defrost (Heater) Relay 9 Strip the end of the wires used for the defrost control. 9 Locate the remaining female spade connectors in the accessories kit. Crimp on the female connectors. Plug the connectors to the COM and NO positions of the Defrost Relay. Confirm combined heater load is not over 0 amps. Liquid line solenoid /Compressor Relay 10 Strip approximately 1/4 of wire insulation on the end of the wires the will be used for the liquid line solenoid 10 Locate a 3 position connector from the accessories kit. Fasten the wires to the screw terminals. Plug into the location as indicated in Wiring Schematic. Max relay rating is 3A Auxiliary Relay 11 Strip approximately 1/4 of wire insulation on the end of the wires to be used for the alarm Locate a 3 position connector from the accessories kit. Fasten the wires to the screw terminals. Plug into the location as indicated in Wiring Schematic. Max relay rating is 3A 11

Page 6 Before installing the safety cover, plug in any remaining connectors to store for future use. Install Safety cover 1 Once all of the high voltage wiring is complete, install the metal cover on the controller. 1 Locate the cover and 3 small screws from the accessories kit. Position the cover over the 3 mounting posts. Using the course threaded screws attach the controller to the plastic posts. Use the fine threaded machine screw with lock washer to fasten the controller to the metal post. Set the controller in a safe place. 13 Preparing the Evaporator The evaporator wiring will require access to the high voltage terminal block on the coil. 13 Turn off power to the system. Verify power is no longer present using a multimeter. Evaporator wiring 14 Now that the conduit is prepared, it can be connected to the evaporator. Locate the proper sized knockout and carefully remove knockout. Connect conduit to the evaporator 14

Page 7 Study the existing wiring. 15 Determine the location of the following: incoming power, fan leads, heater leads, defrost termination leads, and fan delay leads. 15 Evaporator wiring Controller 16 Strip the end of the wires used to power the controller. Attach to the line power to provide continuous power to the controller. Attach ground wire. Note: Ground is required for the internal safeties to operate properly. Evaporator wiring Fans 17 Strip the ends of the wires (connected to the KE Evap) used to control the evaporator fans. The fan wires can be attached to the terminal block using either screw down terminals or spade connectors. Attach one of wires to the L1/Line. This wire will be connected to COM of fan relay on the controller. Attach the wire connected to the NO terminal on the Fan Relay to one of the fan leads. Connect L/Neutral to remaining fan lead. Evaporator wiring Heater 18 Strip the ends of the wires being used for heater control. The heater wires can be attached to the terminal block using either screw down terminals or spade connectors. Remove defrost termination (Klixon ) from circuitry 19 Attach one of wires to the L1/Line. This wire will be connected to COM of defrost relay on the controller. Attach the wire connected to the NO terminal on the Defrost Relay to one of the defrost leads. Connect L/Neutral to the remaining defrost lead. The defrost safety should not be removed from the circuit. Its purpose is to prevent the heaters from over heating and causing damage. Evaporator wiring Liquid Line Solenoid /Compressor 0 Strip the ends selected to control the liquid line solenoid. Attach the wire from the NO terminal on the L.L. Solenoid/ Compressor relay to one of the solenoid leads. Attach the wire from the COM on the L.L. Solenoid/Compressor relay to the L1/Line Voltage. Connect L/Neutral to the remaining L.L. Solenoid/Compressor lead. 16

Page 8 17 18 Wiring Schematic - Controller New Installation 19 0 Legend EFM - Evaporator Fan Motor DH - Defrost Header LLS - Liquid Line Solenoid AUX - Auxiliary PT - Pressure Transducer TSUCTION - Suction Temperature TAIR - Return Air Temperature TCOIL - Evaporator Coil Temperature TAUX - Auxiliary Temperature EEV - Electric Expansion Valve D1 - Digital Input 1 D - Digital Input D3 - Digital Input 3 - - - By others All field wiring must conform to local codes

Page 9 Wiring Schematic - Controller with Contactor Box Existing Defrost Heaters Con Max Current Ratings (Amps are Total All Heaters) Relay Box P/N 30V 3Ø 460V 3Ø 575V 3Ø 017 54 Amps 5 Amps 5 Amps 018 68 Amps 65 Amps 6 Amps 019 80 Amps 77 Amps 6 Amps Evaporator Fan Motors Con1 Max HP & Amp Ratings (Total All Fans) Voltage Max HP Max AMPS 30 3e 15 4 460 3e 30 40 575 3e 30 3 P/N: 017-50A 018-65A 019-80A Legend EFM - Evaporator Fan Motor DH - Defrost Header LLS - Liquid Line Solenoid AUX -Auxiliary PT - Pressure Transducer TSUCTION - Suction Temperature TAIR - Return Air Temperature TCOIL - Evaporator Coil Temperature TAUX - Auxiliary Temperature EEV - Electric Expansion Valve D1 - Digital Input 1 D - Digital Input D3 - Digital Input 3 - - - By others All field wiring must conform to local codes Contactor ratings per UL508 CSA.

1 Page 10 Evaporator wiring Auxiliary The auxiliary relay is optional and wiring will vary depending on the auxiliary relay method selected. Depending on auxiliary relay location, an additional conduit may be required. Strip the ends selected to control the auxiliary component. Break the hot leg of the auxiliary component. Attach the wire from the NO terminal on the auxiliary relay to one of the auxiliary component leads. Attach the wire from the COM on the auxiliary component relay to the L1/Line Voltage. Connect L/Neutral to the remaining auxiliary component lead. Route and secure the conduit to the location the controller is to be installed. Wiring must follow local wiring codes. Installing the sensors Although not required, sensors should be labeled with their function. This will eliminate confusion when connecting the sensors to the controller. Air Sensor Bracket Install the Air Temperature Sensor using the Stainless Steel selfpiercing screw and bracket from the accessory kit. The end with the single loop is designed to be mounted with the screw included. The end with multiple loops is designed to hold the sensor. Locate the best place to install the sensor. The sensor should be located between 6 and 1 inches away from the face of the evaporator. This distance prevents the sensor from sensing heat from the heating elements during the defrost cycle, but close enough to accurately sense the return air temperature. The sensor bracket may be bent as necessary to locate the sensor in the proper position. WARNING! Do not allow the metal portion of the air sensor to touch anything other than air. It should not touch the bracket, nylon cable tie, or any other solid surface. 3 3

Coil Sensor 4 4 The coil sensor location is of the utmost importance for the proper operation of the controller. It is essential that the sensor is in the coldest location on the coil at the end of the defrost cycle, to ensure a complete defrost. Extending sensor wires After the sensors are mounted, they are routed back to the controller. If the sensors are mounted within 10 feet of the controller, the included wiring may be used without modification. If the installation requires more than 10 feet, the wires must be extended using 18 gauge twisted shielded pair. Maximum length for 18 gauge: 100ft. When running the wires back to the controller care must be taken to avoid interference being introduced into the sensor wires. Interference can be introduced when sensor wires are located near high voltage lines. High voltage is defined by United Laboratories as being above 30V. The higher the voltage the more likely it is to introduce interference and the more important to avoid. If crossing a high voltage line is necessary, the sensor wiring should be run at right angles to prevent noise. Sensor mounted on same side of coil as distributor tube entry. Electric Defrost - Surface Heater Heater Coil Heater Coil Higher Frost Zone coldest part of evaporator Electric Defrost - Dropped Tube Higher Frost Zone coldest part of evaporator 3 3 Page 11 Ideal Sensor Location - 1/ way between heater coils 1/ way - insert perpendicular to face of coil - pinch fins together to hold 3 Ideal Sensor Location - 1/ way between heater coils - approx. 3 from top and 3 from side - insert parallel to face of coil - pinch fins together to hold suction header sensor located on the refrigerant side of coil Air Defrost / Hot Gas Defrost Ideal Sensor Location - lower corner nearest expansion valve, approx. 3 from bottom, and 3 from side - insert parallel to face of coil - pinch fins together to hold 3 3 suction header sensor located on the refrigerant side of coil

Page 1 Connecting sensor wires to controller 5 5 The temperature sensors are designed to be attached to the controller using position screw terminals. Using a connector from the accessory kit, attach the sensor to the screw terminal. The sensors are not polarized, so wire location does not effect sensor performance. Connect all sensors to a screw terminal. Once connected, the sensors should be plugged into the proper location on the controller. The location can be determined from the label on the interior wall of the enclosure or from the Wiring Schematic. Strain relief The enclosure has been designed with a strain relief bar to prevent the sensor wires from becoming unplugged from inadvertent contact. Before securing the sensor wires, create a service loop as shown in Figure 5. Using a cable tie from the accessory kit, securely fasten the sensor wires to the strain relief bar. Note: Unused connectors should be placed (installed) in their respective location for future use. Controller Mounting Locate the mounting template and 4 stainless steel screws in the accessories kit Install the 4 screws Remove the template and discard. Place the controller on the mounting screws and tighten down the screws. 6 6 7 Final Step Leave the installation instructions onsite in a convenient location, where it can be easily located, for future service.

Page 13 Voltage Selector 10V - Jumpers 1& 3&4 08-40V Jumper &3 only 08-40 10 10 1 3 4 Transformer 18V Power In line / L1 ground neutral / L COM NO NC COM NO NC Fuse Bk/MDL-1/4 Time Delay Power In Fan Relay (10 amp) Defrost (Heater) Relay (0 amp) 3A Relay NC COM NO 3A Relay NC COM NO COM NC NO COM NC NO Liquid Line Solenoid (compressor) Alarm Relay *Beacon I *Beacon II yellow blue red white black Digital Inputs pumpdown door switch dual temp setting brown green white yellow Electric Valve* blue *Beacon II red white black Table 1 - Specifications Controller Input Voltage: 10V or 08-40V Ambient Temp: -40 to 140 F DI 1 DI DI 3 ground red green white black Temperature Sensors (4) Operating Temp: -40 to 140 F Display: 4 digit alphanumeric LED IP Rating: IP65 Inputs: 4 temperature sensors (KE SKU 000) 1 pressure transducer (KE SKU 004) Valve Types: unipolar and bipolar stepper motors (1V); (Beacon II is 1V) Relays: 0A resistive (defrost); 10A inductive (evaporator fan) 3A inductive rated cycles Digital Input 1 & : door contact, use nd air temp setpoint, disabled, system off, external alarm notification Digital Input 3 door contact, use nd air temp setpoint, disabled, system off, external alarm notification, lights, camera Communication: Standard TCP/IP Temperature Sensors Pressure TAux TCoil TAir TSuct Transducer green red black signal +5 ground RJ45 Ethernet Connection Pressure Transducer Wiring Detail Pressure Transducer Pressure Transducer Pressure Range: Proof Pressure: Burst Pressure: 0 to 150 psia 450 psi 1500 psi Operating Temp: -40 to 75 F Temperature Sensor Sensor Specs: Not Used black red green -60 to 150 F moisture resistant package

Page 14 Parameter Name Table - Controller Menus and Menu Parameters Setpoints Menu - STPT Description ROOM TEMP DEFROST TYPE VALVE TYPE Room temperature to be maintained Method of defrost used on the evaporator coil: Electric, Air, Hot Gas with Liquid Line Solenoid/Compressor relay off, Hot Gas with Liquid Line Solenoid/compressor r Type of valve used on the system: mechanical, pre-configured electric, custom EEV configuration Custom EEV Only MOTOR TYPE MOTOR STEP RATE MAX VALVE STEPS SUPERHEAT MAX OPERATING PRES REFRIGERANT AUX TEMP MODE If VALVE TYPE = CUSTOM: The motor type used in the valve If VALVE TYPE = CUSTOM: The motor speed setting in number of steps per second If VALVE TYPE = CUSTOM: The total number of steps required to move the valve from closed to fully open The superheat value that the controller will maintain, (not applicable if VALVE TYPE = MECHANICAL) The maximum allowable suction pressure, (not applicable if VALVE TYPE = MECHANICAL) The type of refrigerant used in the refrigeration system Configuration mode of the auxiliary temperature sensor AUX RELAY MODE MIN COMP RUN TIME MIN COMP OFF TIME REFRIG FAN MODE DEFROST MODE DEFROSTS / DAY 1ST DEFROST DELAY DEFROST FAN STATE DEFROST TERM TEMP Configuration mode of the auxiliary relay. Minimum amount of time the liquid line solenoid/compressor relay must remain on after it is energized Minimum amount of time the liquid line solenoid/compressor relay must remain off before it can be energized again. Fan operation while in refrigeration mode The method the controller uses to determine when to initiate a defrost. If DEFROST MODE = SCHEDULED: The number of evenly spaced defrosts per day the controller will initiate. If DEFROST MODE = SCHEDULED: The amount of time from controller power up until the first defrost is initiated. Whether or not to run the evaporator fans during defrost The temperature the coil sensor(s) must exceed in order to terminate defrost. The defrost relay is de-energized at this point. Bonded Controllers Only Defrost parameter DRAIN TIME COMP RUN TIME ELEC DEFROST MODE FAN DELAY TEMP MAX FAN DELAY TIME PUMP DOWN TIME MULTI AIR TEMP CTRL MULTI EVAP COOL MULTI EVAP DEFROST MULTI EVAP SENSOR HIGH TEMP ALARM OFFSET HIGH TEMP ALARM DELAY LOW TEMP ALARM OFFSET LOW TEMP ALARM DELAY DOOR ALARM DELAY DIG IN 1 MODE DIG IN 1 STATE DIG IN MODE DIG IN STATE DIG IN 3 MODE The maximum amount of time the defrost relay will be energized. Time to be in drain mode (drip time) If DEFROST MODE = RUN TIME: The amount of time liquid line solenoid/compressor relay is energized before the next defrost is initiated. If DEFROST TYPE = ELEC: Whether to leave the defrost relay energized during the defrost cycle or to utilize advanced defrost algorithm. After defrost, the coil sensor reading must fall below this temperature set point in order for the controller to resume normal fan operation. Maximum amount of time after defrost to resume normal fan operation. Minimum amount of time between de-energizing the liquid line solenoid/compressor relay and energizing the defrost relay. Select control method to use with multiple room temperature sensors Select type of multi evaporator control - options are synchronous or independent Select whether to have all bonded controllers initiate defrost mode at the same time or independently. Select whether or not to share room temperature, coil temperature and suction pressure sensor data with bonded controllers. The number of degrees above ROOM TEMP for a HIGH TEMP ALARM condition. The amount of time, in minutes, the room temperature must remain above ROOM TEMP + HIGH TEMP ALARM OFFSET before issuing a HIGH TEMP ALARM The number of degrees below ROOM TEMP for a LOW TEMP ALARM condition. The amount of time, in minutes, the room temperature must remain below ROOM TEMP - LOW TEMP ALARM OFFSET before issuing a LOW TEMP ALARM If DIG IN (1, and/or 3) MODE = DOOR SWITCH: The amount of time, in minutes, before an alarm condition is initiated if door is open and room temperature is 5 de above ROOM TEMP + AIR TEMP DIFF Sets the function of the digital input Sets whether the switch activates when opened or closed Sets the function of the digital input Sets whether the switch activates when opened or closed Sets the function of the digital input DIG IN 3 STATE Sets whether the switch activates when opened or closed ND ROOM TEMP If DIG IN (1, and/or 3) MODE = ND ROOM TEMP: This value becomes the ROOM TEMP setpoint when the digital input is active SUCT PRES OFFSET An offset added or subtracted from the suction line pressure transducer reading to calibrate, if needed SUCT TEMP OFFSET An offset added or subtracted from the suction temperature sensor reading to calibrate, if needed AIR TEMP OFFSET An offset added or subtracted from the room temperature sensor reading to calibrate, if needed COIL TEMP OFFSET An offset added or subtracted from the coil temperature sensor reading to calibrate, if needed AUX TEMP OFFSET An offset added or subtracted from the auxiliary temperature sensor reading to calibrate, if needed TEMP UNITS Units for temperature s display in F or C AIR TEMP DIFF The number of degrees above ROOM TEMP before the controller will go into REFRIGERATION mode EXTREME TEMP DIFF ADVANCED TOPIC: Call KE Therm for assistance

Page 15 Range Default Current -50 F to 90 F elay on ELEC, AIR, HOT GAS COMP ON, HOT GAS COMP OFF ELEC MECHANICAL, KE, SER/SEI 1 TO 0, SER B TO L, SEI 30, SEI 50, SEH, ETS1 TO 50, ETS100, MECHANICAL ETS50/400, KV, CAREL, CUSTOM; BIPOLAR, UNIPOLAR BIPOLAR 30 to 400 steps/second 00 steps grees -10 F 00 to 6400 steps 1600 steps 5 F to 30 F 8 F 10 to 150 psig 150 psig 404A, R507, 407A, 407C, 4A, 4D, 134A, R, R717, 438A, 408A, 409A, 410A, R744 404A DISABLED, MONITOR, ND AIR TEMP, ND COIL TEMP DISABLED ALARM RELAY, SPEED FAN CTL, ND COMP RELAY, ND FAN RELAY, ND DEFR RELAY, ALARM RELAY LIGHT RELAY, CAMERA RELAY 0 to 15 minutes minutes 0 to 15 minutes 5 minutes ON WITH COMPRESSOR, PERMANENT, CYCLE DEMAND, SCHEDULED, RUN TIME 0 to 8 5 ON WITH COMPRESSOR DEMAND 0 to 40 minutes 10 minutes ON/OFF OFF if DEFROST TYPE = ELEC, HOT GAS COMP ON, HOT GAS COMP OFF ON if DEFROST TYPE = AIR 35 F to 90 F 50 F if DEFROST TYPE = ELEC, HOT GAS COMP ON, HOT GAS COMP OFF 40 F if DEFROST TYPE = AIR 5 minutes if DEFROST TYPE = ELEC 0 to 90 minutes 10 minutes if DEFROST TYPE = HOT GAS COMP ON, HOT GAS COMP OFF 40 minutes if DEFROST TYPE = AIR 0 to 15 minutes minutes 0 to 4 hours 6 hours PULSE, PERMANENT -40 F to 35 F 0 F PULSE 0 to 0 minutes minutes 0 to 10 minutes 0 minutes AVERAGE, WARMEST SYNC, INDEPENDENT SYNC, INDEPENDENT SHARED, NOT SHARED 0 F to 99.9 F 10 F WARMEST SYNC SYNC SHARED 0 to 10 minutes 60 minutes 0 F to 0 F 4 F 0 to 30 minutes 10 minutes 0 to 180 minutes DISABLED, ND ROOM TEMP, DOOR SWITCH, EXT ALARM, SYSTEM OFF OPEN, CLOSED DISABLED, ND ROOM TEMP, DOOR SWITCH, EXT ALARM, SYSTEM OFF OPEN, CLOSED DISABLED, ND ROOM TEMP, DOOR SWITCH, EXT ALARM, SYSTEM OFF, LIGHT SWITCH, CAMERA SWITCH OPEN, CLOSED -50 F to 90 F 30 minutes DOOR CLOSED DISABLED CLOSED DISABLED CLOSED -50 F -5.0 to 5.0 psig 0.0 psig -5.0 F to 5.0 F -5.0 F to 5.0 F -5.0 F to 5.0 F -5.0 F to 5.0 F FAHRENHEIT/CELSIUS 0 F to 5 F 1 F 0.0 F 0.0 F 0.0 F 0.0 F FAHRENHEIT

Page 16 Manual Menu Parameter Name Description Range Default MANUAL CONTROL Force the controller into the next operating mode COOL, OFF, DEFROST, DRIP TIME, FAN DELAY MANUAL VALVE Manually open or close the electronic expanion valve in percentage increments 1% increment CLEAR ALARMS Clear all active alarms MANUAL COMPRESSOR RELAY Manually energize or de-energize liquid line solenoid /compressor relay Auto (on/off), Manual off, Manual on AUTO MANUAL DEFROST RELAY Manually energize or de-energize defrost relay Auto (on/off), Manual off, Manual on AUTO MANUAL FAN RELAY Manually energize or de-energize evaporator fan relay Auto (on/off), Manual off, Manual on AUTO DHCP ADVANCED TOPIC, SEE USER GUIDE: Selects appropriate DHCP mode OFF, CLIENT, SERVER OFF FACTORY RESET Reset the controller to the factory default setpoints RESET Variables Menu - Non Adjustable (view only) Parameter Name Description ROOM TEMP Room temperature as measured by the controller COIL TEMP Coil temperature as measured by the controller SYSTEM MODE Current operating status SUPERHEAT Superheat as calculated by the controller (requires suction pressure transducer and suction temperature sensor) SUCTION PRESSURE Suction pressure as measured by the controller SUCTION TEMP Suction temperature as measured by the controller SATURATION TEMP Saturation temperature as calculated by the controller VALVE % OPEN Percentage the EEV is open AUX TEMP Auxiliary Temperature (Taux) sensor reading as measured by the controller COMPRESSOR RELAY Current state of liquid line solenoid/compressor relay DEFROST RELAY Current state of the defrost relay FAN RELAY Current state of the evaporator fan relay DIG 1 STATUS Current status of the Digital Input #1 DIG STATUS Current status of the Digital Input # DIG 3 STATUS Current status of the Digital Input #3 IP OCTET 1 The first three digits of the IP address IP OCTET The second three digits of the IP address IP OCTET 3 The third three digits of the IP address IP OCTET 4 The fourth three digits of the IP address SUBNET MASK OCTET 1 The first three digits of the subnet mask address SUBNET MASK OCTET The second three digits of the subnet mask address SUBNET MASK OCTET 3 The third three digits of the subnet mask address SUBNET MASK OCTET 4 The fourth three digits of the subnet mask address FIRMWARE VERSION Current version of the firmware on the controller Variables Menu Options for DIG IN MODE DIG IN Setting Status Displayed on Controller DIG IN MODE = DISABLED DIG IN MODE = ND (ROOM) TEMP DIG IN MODE = DOOR SWITCH DIG IN MODE = EXT ALARM DIG IN MODE = SYSTEM OFF DIG IN MODE = LIGHT SWITCH DIG IN MODE = CAMERA SWITCH Alarms Status Menu Non Adjustable (view only) Parameter Name Description NO ALARM PRESSURE SENSOR SUCTION TEMP SENSOR AIR TEMP SENSOR COIL TEMP SENSOR AUX TEMP SENSOR HIGH SUPERHEAT LOW SUPERHEAT HIGH AIR TEMP LOW AIR TEMP EXCESS DEFROST DEFR TERM ON TIME DOOR SWITCH COMMUNICATION ERROR EXT ALARM DISABLED inactive = ND ROOM TEMP OFF; active = ND ROOM TEMP ON inactive = DOOR CLOSED; active = DOOR OPEN inactive = NO ALARM; active = EXT ALARM (x) inactive = SYSTEM ON; active = SYSTEM OFF inactive = LIGHTS OFF; active = LIGHTS ON inactive = CAMERA OFF; active = CAMERA ON No alarms active, everthing is running correctly Suction pressure sensor is shorted, open or pressure out of range Suction temperature sensor is shorted or open Return air temperature sensor is shorted or open Coil temperature sensor is shorted or open Auxiliary temperature sensor is shorted or open Superheat above upper limit Superheat below lower limit Room temperature is above ROOM TEMP + AIR TEMP DIFF + HIGH TEMP ALARM OFFSET for longer than HIGH TEMP ALARM DELAY Room temperature is below ROOM TEMP - LOW TEMP ALARM OFFSET for longer than LOW TEMP ALARM DELAY Three consecutive defrosts with less than a one hour interval between each defrost Defrost terminated on time instead of temperature for two consecutive cycles If door is open and room temperature is 5 degrees above ROOM TEMP + AIR TEMP DIFF for DOOR ALARM DELAY time ONLY FOR BONDED CONTROLLERS: No communication between controllers for one minute or more If DIG IN (1, and/or 3) MODE = EXT ALARM: The digital input is in an active state KE Therm Solutions 09 Lange Dr.. Washington, MO 63090 1-888-337-3358. www.ketherm.com