Improvements in Transmission Control Center Alarm Management Practices

Similar documents
SCADA ALARM MANAGEMENT. Tim Okely. GWMWater

Alarm Management: EPRI Survey on the State of Technology

Effective Alarm Management for Dynamic and Vessel Control Systems

The Top 10 Worst Performing Alarm Systems in Industry

Alarm System Performance Metrics

Where Technology Shapes Solutions. Alarm management : Wasn t that problem already solved years ago?

Economic and Effective Alarm Management

02 21st Century Trends Resources 8/24/2017. Trends in Human Machine Interface (HMI) Old School Trends. The Future of HMI

FAST/TOOLS. Alarm System Performance Analysis (ASPA) Bulletin 50A01A00-02EN

Q&A Session from Alarm Management Workflow Webinar (Apr.24/2013)

Alarm Management Optimization (AMO) at Saudi Aramco

Next Generation Alarm Management With DynAMo Alarm and Operations Management

DynAMo Alarm & Operations Management

PERFORMANCE HUMAN NEXT-GENERATION SCADA HIGH. MACHINE INTERFACES Configuring HMIs to Display Operator-centric Information

Alarm Management Plan

excellence in Dependable Automation ALARM MANAGEMENT

DeltaV Analyze. Introduction. Benefits. Continuous automated DeltaV System alarm system performance monitoring

Too Many Alarms: Where Do I Begin?

Alarm Management for SCADA control rooms

2012 Honeywell Pacific Users Group. Sus tain.ability.

Exaquantum/ARA Alarm Reporting and Analysis

Alarm Management Reflections

Alarm Management Implementation on a Plant. Standards Certification Education & Training Publishing Conferences & Exhibits

TRANSMISSION ENGINEERING STANDARDS SUBSTATIONS

Experiences from Intelligent Alarm Processing and Decision Support Tools in Smart Grid Transmission Control Centers

Ovation Alarm Management System

Classifying Forced Outages Transmission Maintenance Procedure No. 5

Embracing Change: High Performance Graphics to Improve Operations Water/Wastewater Case Study

Alarm Management Standards Are You Taking Them Seriously?

MNEC NFPA 72 WHITE PAPER

Alarm Management Services

Enhance Alarm Management

Understanding and Applying the ANSI/ISA 18.2 Alarm Management Standard

Session Number: 3 Making the Most of Alarms as a Layer of Protection

ISA 18.2 WG8. Purpose Definitions Status. By: Lieven Dubois, Co-chair

Alarm Management. Version Prepared by: Michael Davis- Hannibal. Softcon Software Control Services (Pty) Ltd.

TRANSMISSION ENGINEERING STANDARDS SUBSTATIONS

Sustain.Ability. Alarm Management: Be Pro-active, not Re-active Honeywell Users Group Europe, Middle East and Africa. Tyron Vardy, Honeywell

CAN/ULC-S1001, INTEGRATED SYSTEMS TEST OF FIRE PROTECTION AND LIFE SAFETY SYSTEMS

NFPA Self Assessment Manual

IRO Reliability Coordinator Real-time Reliability Monitoring and Analysis Capabilities

Critical Condition Management on a Corporate Scale. Lyondell Is a Major Global Chemical Company

Alarm Management. Alarm Management. DeltaV Whitepaper. February 2011 Page 1

Lecturer: Jim Clauston. Course: QAS 515 Human Factors Engineering in Quality. Term Paper Title: Alarm Management on an Oil & Gas Offshore Platform

Alarm Services. Introduction. Benefits. Service Data Sheet October Know and improve your alarm performance

excellence in Dependable Automation The Alarm Shelving ebook

Cool, calm and collected No cause for alarm on the Grane oil rig

Closing the Holes in the Swiss Cheese Model Maximizing the Reliability of Operator Response to Alarms

KELTRON LS 7000 ALARM MANAGEMENT SYSTEM Keltron Alarm Monitoring, Dispatch, and Reporting Software

Leak Detection Program Management (RP 1175) April 24-26, 2018 St. Louis, Missouri

Benchmarking Industry Practices for the Use of Alarms as Safeguards and Layers of Protection

SolarPower Europe O&M Task Force

FIRE AND LIFE SAFETY EDUCATOR II NFPA 1035, Chapter 5, 2015 Edition

G GAS EQUIPMENT FOR DUAL-FUEL INTERRUPTIBLE SERVICE UNDER CLASSIFICATION NO. 12 PRIORITIES AB, C, D, AND E

DeltaV Analyze. DeltaV Analyze. Introduction. DeltaV Product Data Sheet. Continuous automated DeltaV System alarm system performance monitoring

Alarm Management for Pipelines

Applying Performance-based Fire Alarm System Design Part 4

The 2013 National Fire Alarm and Signaling Code

Compliance with Lighting Standards and Management Systems (ANSI C137)

SPANISH TOWN, ST. CATHERINE JAMAICA

API RP 1175 Pipeline Leak Detection Leak Detection Program, Culture, & Strategy

ABB Ability System 800xA Alarm Management

Standard PRC-005-4(X) Protection System, Automatic Reclosing, and Sudden Pressure Relaying Maintenance

Dennis Mullen System Operations Manager

Alarms play a significant role in maintaining plant

DATA SHEET BENEFITS CURRENT CHALLENGES SSM INFOTECH S X-FORCE AMS - THE IDEAL SOLUTION

What Utility Analytics means to Exelon

The Role of Engineering Judgement in Fire and Gas (F&G) Mapping

I/A Series A 2 Software FoxAlert Alarm Manager

CAN/ULC S Integrated Systems Testing of Fire Protection and Life Safety Systems and Fire Protection Commissioning

Because Safety is not found in a Box

Scope of Work Urban Design Review Framework Monitoring Program Item #7.1

First Nations Emergency and Issue Management and Fire Protection Programs

2012 Honeywell Users Group EMEA Tyron Vardy A Guide to Effective Alarm Management

TECHNICAL DATA SHEET ADDRESSABLE FIRE ALARM SYSTEMS FIRE ALARM CONTROL PANEL LF-6100 A 1/2

Standard Development Timeline

To: Honorable Public Utilities Board Submitted by: /s/ Douglas Draeger AGM Engineering and Operations

Batt-Safe Battery String Monitoring System

Stafford County Strategic Plans

ESF 15: EMERGENCY PUBLIC INFORMATION

General Specifications

NFPA 72 Code Changes vs 2013

2018 WORK PLAN. Land Use & Ethics Training presented by: Assistant City Attorney, Natasha Zimmerman

CAN/ULC-S1001, INTEGRATED SYSTEMS TESTING OF FIRE PROTECTION & LIFE SAFETY SYSTEMS Simon Crosby, LEL, CET, CFPS October 21, 2015

Managing Alarms to Support Operational Discipline

Update and Overview on the NFPA Requirements and Testing for Electronic Safety Equipment

Rules for Classification and Construction Additional Rules and Guidelines

Implementing sustainable water strategy through development industry engagement

Analyze IT. Process Gas Chromatograph. PGC2000 Series

A. Introduction 1. Title: Transmission and Generation Protection System Maintenance and Testing

City of Los Angeles Office of the Controller

Electric Service Requirements

Current Trends in SCADA Systems. Situational Awareness Alarm Management Data Availability System Robustness/Redundancy

Securing the operational readiness of fire control systems

Public Notice of Amendment to New Shoreham General Ordinances Chapter 5 Fire Prevention and Protection New Article IV Fire Alarm Ordinance

Architectural and Engineering Specification for a Security Management System. StarNet 2

Keeping the peace (and quiet)

Human Performance Models for Response to Alarm Notifications in the Process Industries: An Industrial Case Study

RESOLUTION MSC.86(70) (adopted on 8 December 1998) ADOPTION OF NEW AND AMENDED PERFORMANCE STANDARDS FOR NAVIGATIONAL EQUIPMENT

ZONING AMENDMENT & PLANNED UNIT DEVELOPMENT STAFF REPORT Date: April 4, 2013

Transcription:

Improvements in Transmission Control Center Alarm Management Practices Navin Bhatt, Mahendra Patel, Bill Hollifield, Andrew Hunter 2017 CIGRE Grid of the Future Symposium Cleveland, Ohio, U.S.A. 22-25 October, 2017

Alarm Management in Control Centers Volume & complexity of alarms have been increasing Operators interested in better alarm management processes and tools EPRI R&D During 2014-2016: 2 Workshops, 2 Surveys, 3 Site Visits, Literature Search Made observations and identified improvement opportunities Prepared a guide to develop an Alarm Management Philosophy document Initiated case studies (to address improvement opportunities) 2

Aug. 2015 Alarm Management Workshop and Follow-Up Survey 5 Importance of Alarm Management Issues (5=High; 1=Low) 4 3 2 1 0 Nuisance Alarms/ Alarm Flooding Alarm Grouping/ Filtering/ Prioritizing Root Cause Analysis Alarm Interface & Visualization Alarm Mgmt. Philosophy Training of Available EMS Integrated Alarm Mgmt. Functions

3002009925 Free to public 30-Page report published in March 2017 Contents: Chapter 17 of 3002008274 published in November 2016 4

Improvement Suggestions 1. Develop and adopt an Alarm Philosophy Document 2. Segregate TCC alarm data. Isolate true alarms. 3. Assign alarm priorities based on accepted practices 4. Ongoing: Monitor alarm system performance using accepted key performance indices (KPIs) 5. Identify and resolve the most frequent and nuisance alarms 6. Develop new higher level graphics 5

Definition of An Alarm IEC/ISA: An alarm is a visible and audible notification to the operator, of an equipment malfunction, process deviation, or abnormal condition requiring a timely operator response. An intentional interruption to the operator Reserved only for notification of situations that require the operator to take action Timely Response: Immediate to within 30 minutes 6

Observation: TCC Alarm System TCC alarms currently consist of scrolling data strings on operator consoles that can be segregated into 3 categorizes: 1. Alarm - actionable in immediate timeframe 2. System Status Information - for operators situational awareness 3. Pass Through Information - that does not require any operator awareness or action (meant for equipment personnel). 7

Improvement Suggestion: Segregation of Alarm Data 1. TCC Alarm System A separate EMS window to display true alarms 2. System Status Indication System A different EMS window to display system status notifications (used for situational awareness) 3. Pass-Through Information Transmit directly to the interested staff (e.g. equipment SMEs) This does not require EMS replacement or even upgrade. 8

EMS Segregation: Now: To Be: The EMS ALARM SYSTEM The EMS STATUS INDICATION SYSTEM 9

Philosophy Document A Comprehensive Set of Guideline for Alarm development, implementation, maintenance, treatment and modification Roles & Responsibilities Consistent and Optimum Basis for Alarm selection; Priority determination; Configuration Basis for Performance Monitoring KPIs; Nuisance Alarm Resolution 10

Case Study 1: Baselining Alarm System Performance Purpose: Benchmark the performance of TCC alarm management system Scope: Analyze historical data of at least 8 weeks Measure performance using KPIs Identify frequent and/or nuisance alarms Identify chattering alarms Identify alarm floods Review the priority criteria Metrics (Targets) IEC/ISA OVERLOADED REACTIVE STABLE ROBUST PREDICTIVE Improvement Plans : Specific Steps to move from each classification to the next. Figure 3-1 Alarm System Performance Levels 150 alarms / day (acceptable); 300 alarms / day (maximum manageable) Priority Distribution: 1 (5%); 2 (15%); 3 (80%) 11

Baselining Analysis of FirstEnergy Alarm Data Data for one Switching Desk in our Western Area 6 Months of Data (181 Days) 275,565 Alarms received during the period Alarms per day (Target: 150-300) Average: 786. Peak: 6467. Minimum: 170 Alarm Flooding (10 or more alarms in 10 minute period) 26.3% of the time Top Ten most frequent Specific Alarms One device at one substation accounted for 11.4% (34,502) of all alarms A transformer alarm accounted for 9% (24,772) of all alarms Most Frequent Alarm Types Communication Non Critical -18.8% All Voltage Alarms -18.1% Other Communication Alarms - 17.1% FirstEnergy Transmission Operations 2015 12

Baselining Analysis of FirstEnergy Alarm Data 8000 7000 Step 1 - All Alarms Step 2 - Without the NORMALS First Energy Alarms Per Day What-If Scenarios 6000 Step 3 - Without Top 2 and 2 others Step 4 - Chattering Eliminated 5000 ISA-18.2 Maximum ISA 18.2 Acceptable 4000 3000 2000 1000 0 10/23/2016 11/23/2016 12/23/2016 1/23/2017 2/23/2017 3/23/2017 FirstEnergy Transmission Operations 2017 13

Lessons Learned Large percentage of alarms created by a few points We are asking Operators to decide which alarms to ignore, rather than only providing actionable alarms because of volume Cleaning up a few items can make a huge difference in number of alarms received FirstEnergy Transmission Operations 2017 14

Next Steps Address Chattering Alarms 20% of alarms from two points Evaluate the Need for return to normal as an alarm Almost 50% of alarms are return to normal Are there better way to address certain alarms Voltage Monitoring Door Alarms Segregate Current Alarms Alarms Situational Awareness Information Pass Through Equipment Information Develop Overall Alarm Philosophy FirstEnergy Transmission Operations 2017 15

Questions? FirstEnergy Transmission Operations 2017 16

Together Shaping the Future of Electricity 17