NORTH STORM. 4-in-1 AIR CONDITIONER USER MANUAL TABLE OF CONTENTS

Similar documents
Progress plus Instruction manual

Koolbreeze. Portable Air-conditioner User s Manual. For Model : CLIMATEASY 14 P14HCP. Downloaded from manuals search engine

Owner s Manual. Portable Air Conditioner ARP-5008 ARP Royal Sovereign International, Inc.

PAC12J. 12,000btu Cool & Heat Portable Air Conditioner. Please read this manual carefully prior to operating the product.

2.9kW Portable Air Conditioner

2.9kW Portable Air Conditioner

AIR CONDITIONING UNIT

MODELS HS 1300-WS HS-1500-CR HS-1300-TR

PAC12H. 12,000btu Cool & Heat Portable Air Conditioner. Please read this manual carefully prior to operating the product.

MODELS HS 1500-OWO HS-1500-OTR INFRARED ELECTRICAL HEATER SAFETY INSTRUCTIONS & OPERATION MANUAL

PORTABLE AIR CONDITIONER

Downloaded from manuals search engine

PORTABLE AIR CONDITIONER

PORTABLE AIR CONDITIONER (LOCAL)

11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions. Model No. PE4-11R Soleus Air International

PC20-AMFII / PC40-AMF USER MANUAL

Dual-Hose Portable Air Conditioner User Manual

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions

PORTABLE AIR CONDITIONER

GDDEM10 DEHUMIDIFIER

USER INSTRUCTIONS FOR 0.25 LITRE MINI DEHUMIDIFIER - MODEL NO. DHMD025

10L Dehumidifier. Model Number: LDH V AC 50/60Hz 290W

AC-12200E Portable Air Conditioner

15,000 BTU Portable Air Conditioner

Model No. PE2-07R / PE2-09R / 9000 BTU Portable Air Conditioner with dehumidifier & Fan PE2-07R-62 / PE2-09R-32 Operating Instructions

SUKI. Dehumidifier WDH-928DB -20R. User s Manual

USER MANUAL TPS-M5/M55/M555

Portable Air Conditioner. Instruction Manual

Portable Air Conditioner

Mobile Air Conditioner Use and Care Manual. Part Number: 048-GM-48265

12L DEHUMIDIFIER OPERATING INSTRUCTIONS

MODEL: DC10RCDH / DC12RCDH

Whynter Portable Ice Maker 33 lb capacity - White

30-pint Dehumidifier User Guide

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCS. Voltage rating: 115V~60Hz Power rating : 1400W

8L DEHUMIDIFIER OPERATING INSTRUCTIONS

AVAC9000W Portable Air Conditioner with 24 hour timer Installation Instructions and User Guide

20L Dehumidifier. Model Number: LDH V AC 50/60Hz 440W

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

5) Do not start or stop the unit by inserting or pulling out the power plug.

CLIM9000CE PORTABLE AIR CONDITIONER USER MANUAL

Mobile Air Conditioner Instruction Manual Model TC-N9KM

USER MANUAL SILENT16 PORTABLE AIR CONDITIONER

Portable Air-conditioner Use and Care Manual

ARTICA. 8000Btu. Room Air Conditioners Portable Range

Operating Instructions

Model No.: PS08-01 PS10-01 Ref: KY80 KY100

12,000 BTU Evaporative Portable Air Conditioner

DEHUMIDIFIER MODELS: SD-30E / SD-40E / SD-65E INSTRUCTION MANUAL

Operation Manual Portable Room Air Conditioner Models: RPC26WA / RPC35WA / RPC41WA

USER MANUAL SILENT12 PORTABLE AIR CONDITIONER

DUE-1237 DEHUMIDIFIER Owner s Manual

General Care and Safety Guide

Professional HEPA Air Cleaner

Air Conditioner PORTABLE. Instruction Manual. Your Guarantee. Portable Air Conditioner / Heater. For models WA-1010E, WA-1010H, WA-1010M

Portable Air Conditioner

AC Portable Air Conditioner AC-14100E, AC-14100H OWNERS MANUAL. Read and save these instructions.

USER MANUAL. Safety Precautions. Unit Specifications and Features. Operating Instructions. Installation Instructions.

Portable Air Conditioner with Heat Pump Technology PH4-10R-01, PH4-12R-01, & PH4-14R-01 Operating Instructions

WHYNTER PORTABLE ICE MAKER 49 LB CAPACITY - STAINLESS STEEL

Reverse Cycle Portable Air Conditioner with Dehumidifier

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

WHYNTER PORTABLE ICE MAKER 49 LB CAPACITY - STAINLESS STEEL

20L Electronic Dehumidifier

CR13000-PAC OWNER S MANUAL. Portable Air Conditioner. PORTABLE AIR CONDITIONER with HEAT PUMP. Operating and Servicing Instructions

Operating Instructions

14,000 BTU Portable Air Conditioner 14,200 BTU Heat Pump Model Number: LX-140 Operating Instructions. Model No. LX Soleus Air International

SILENT 12 PORTABLE AIR CONDITIONER USER MANUAL

Portable Air Conditioner, Dehumidifier,Heater and Fan utilizing Heat Pump Technology

Portable Air Conditioner and Heater With Heat Pump Technology Operating Instructions. Model No.: PH3-12R-03 Reference No.: KY2-34

12,000 BTU Portable Air Conditioner PE3-12R-03. Model No. PE3-12R Soleus Air International

DEHUMIDIFIER MODELS: SD-31E / SD-41E / SD-61E / SD-71E INSTRUCTION MANUAL

!3 _!!ili_ '_:_i_;iii_ SG-PAC-12E1 SG-PAC- 12E 1HP. 12,000 BTU Portable Air Conditioner

Portable Air-conditioner

Air Conditioner. Instruction Manual. For Models WA-1010E, WA-1010H, WA-1010M WA-1230E, WA-1230H P O R T A B L E

Local air conditioner

Portable Air Conditioner USER MANUAL

Portable Room Air Conditioner and Heat Pump

Portable Air Conditioner with Heat Pump Technology Operating Instructions. Model No.: HCB-P13HP-D. Reference No.: BPD13HP V140217

Dehumidifier. User Manual

COMPACT PORTABLE AIR CONDITIONER USER MANUAL

12L Dehumidifier Model: HG00923

Instruction Manual. Portable Air Conditioner

AD-250. Dehumidifier OWNERS MANUAL. Read and save these instructions.

Bottled Water Dispenser User Manual

FAN HEATER FH118 User Manual

MeacoDry ABC Range Dehumidifiers

9 LITRE DESICCANT DEHUMIDIFIER INSTRUCTION MANUAL

Portable Air Conditioner with Evaporative Technology PE6-10R-03 Operating Instructions. Model No. PE6-10R Soleus Air International

OWNER S MANUAL OIL FILLED HEATER MODEL:NY-13A1L READ AND SAVE THESE INSTRUCTIONS

PLEASEREADANDSAVETHESEINSTRUCTIONS. NewAir AC-14000E, AC-14000H Portable Air Conditioner Owner's Manual

PORTABLE DEHUMIDIFIER


Air Conditioner PORTABLE. Instruction Manual. Your Guarantee. Portable Air Conditioner / Heater. For model WA-7500M

Portable Air Conditioner User Manual

MINI DEHUMIDIFIER. SD-350TI With UV Light SD-350 INSTRUCTION MANUAL

Model No. SG-PAC-10E2 Reference No. KY ,000 BTU Portable Air Conditioner Operating Instructions

200W Frostwatch Radiant Heater Operation Manual

INSTRUCTIONS FOR CARBON INFRARED HEATER

STORM. Bottom-Load. Water Dispenser User Manual

Transcription:

NORTH STORM 4-in-1 AIR CONDITIONER USER MANUAL MODELS NS 8W-AC NS-10W-AC TABLE OF CONTENTS Safety Awareness.....4 Name of Parts...5 Accessories..........6 Introduction to Panel and Remote Controller........7 Operation Introduction...9 Installation Explanations...12 Maintenance Explanations...14 Troubleshooting... 15

INTRODUCTION Thank you and congratulations on your purchase of your North Storm 8,000 BTU or 10,000 BTU 4-in-1 Unit. PLEASE READ THIS MANUAL BEFORE OPERATING THIS APPLIANCE. WARNING IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, AN ELECTRIC SHOCK OR FIRE MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. WARNING ANY REQUIRED SERVICE OTHER THAN FILTER MAINTENANCE SHOULD ONLY BE PERFORMED BY AN AUTHORIZED SERVICE REPRESENTATIVE AND ANY OTHER REPAIRS ATTEMPTED BY ANYONE OTHER THAN AN AUTHORIZED SERVICE REPRESENTATIVE WILL VOID THE WARRANTY. SAFETY AWARENESS The appliance is for indoor use only. Do not use the unit on a socket under repairs or not installed properly Do not use the unit, follow these precautions: o Near to source of fire. o An area where oil is likely to splash. o An area exposed to direct sunlight. o An area where water is likely to splash. o Near a bath, a laundry, a shower or a swimming pool. Never insert your fingers, rods into the air outlet. Take special care to warn children of these dangers. Keep the unit upward while transport and storage, for the compressor locates properly. Before cleaning the air-conditioner, always turn off or disconnect the power supply. When moving the air-conditioner, always turn off and disconnect the power supply, and move it slowly. To avoid the possibility of fire disaster, the air-conditioner shall not be covered. All the air-conditioner sockets must comply with the local electric safety requirements. If necessary, please check it for the requirements. Children should be supervised to ensure that they do not play with the appliance. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. The appliance shall be installed in accordance with national wiring regulations. Details of type and rating of fuses: F, 250V AC,2A. This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling. Notes: If any parts damage, please contact the dealer or a designated repair shop; In case of any damage, please turn off the air switch, disconnect the power supply, and contact the dealer or a designated repair shop; In any case, the power cord shall be firmly grounded. To avoid the possibility of danger, if power cord is damaged, please turn off the air switch and disconnect the power supply. It must be replaced from the dealer or a designated repair shop. 4

NAME OF PARTS Operation Panel Wind Box Guide ACCESSORIES Front View Main AC Unit Hot-Air Exhaust Hose Hose Connector (Window End) Rear Cover Castor Front Cover SPEED TEMP+ MODE TEMP- TIMER POWER Air Inlet Power Cord Side View Air Inlet Hose Connector (AC End) Window Kit Remote Controller Side View FIG. 1 Rear View 5 6

CONTROL PANEL REMOTE CONTROLLER SPEED TEMP+ MODE TEMP- TIMER POWER POWER : On/Off switch MODE : Mode selector TIMER : Hourly programming SPEED : Fan speed selector TEMP+ : Temperature selector up TEMP- : Temperature selector down FIG. 4 7 8

OPERATION INTRODUCTION Before starting operations in this section: 1) Find a place where there is power supply nearby. 2) As shown in Fig.5 and Fig.5a, install the exhaust hose, and adjust the window position well. 3) Insert the power cord into an grounded AC115V/60Hz socket; 4) As shown in Fig. 6, connect water pump drain hose well (only for using heating model). 5) Press the ON/OFF button to turn on the air-conditioner. Please make sure the unit has been standing upright for at least 2 hours before starting or using. FIG. 5 FIG. 6 FIG. 5a OPERATION INTRODUCTION CONT. Before using Notice: Operation temperature range: Check up whether the exhaust hose has been mounted properly. Maximum Cooling Minimum Cooling Maximum Heating Minimum Heating DB/WB( 0F ) 95/75 64/54 80/--- 45/--- Cautions for cooling and dehumidifying operations: When using functions on cooling and dehumidifying, keep an interval of at least 3 minutes between each ON/OFF. Power supply meets the requirements. The socket is for AC use. Do not share one socket with other appliances. Power supply is AC115V, 60Hz Cooling Operation Press the Mode button till the Cool icon appears. Press the or button to select a desired room temperature. (62-90 F0) Press the Fan Speed button to select wind speed. Dehumidifying Operation Press the Mode button till the Dehumidify Indicator Lamp blinks Set the selected temperature to current room temperature minus 2F0. (62-90F0) Set the fan motor to LOW wind speed. Fan operation Press the Mode button till the Fan icon appears. Press the Fan Speed button to select wind speed. Heating operation (this function is not available for a cold-single unit) Press the Mode button till the Heat icon appears. Press the or button to select a desired room temperature. (62-90F0) Press the Fan Speed button to select wind speed. 9 Drain Hose 10

OPERATION INTRODUCTION CONT. Timer operation Timer ON setting: When the air-conditioner is OFF, press the Timer button and select a desired ON time through the temperature and time setting buttons. Preset ON Time is displayed on the operation panel. ON time can be regulated at any time in 0-24 hours. Timer OFF setting When the air-conditioner ON, press Timer button and select a desired OFF time through the temperature and time setting buttons. Preset OFF Time is displayed on the operation panel. OFF time can be regulated at any time in 0-24 hours. Drainage Internal Tank Water Full Alarm Function The inner water tank in the air-conditioner has one water level safety switches, it controls water level. When water level reaches an anticipated height, the water full indicator lamp lights up. (If water pump is damaged, when the water is full, please remove the rubber blockage at the bottom of unit, and all water will drain outside.) CONTINUOUS DRAINAGE When you plan to leave this unit unused for a long time, please remove the rubber blockage from the drainage hole at the bottom of unit, and connect a drain hose to the lower fixing clip. All the water in the water tank will drain outside. You can drain the water as the above when the unit working at the HEAT mode. If water pump is damaged, continuous drainage can be used, and under this condition, the water pump is not activated. The unit can also work well. If water pump is damaged, intermittent drainage can also be used. Under this condition, when the water full indicator lamp lights up, please connect a drain hose to the lower fixing clip, then all the water in the water tank will drain outside. The unit can also work well. INSTALLATION EXPLANATIONS Installation Explanations: A removal air-conditioner shall be installed in the flat and empty place all around. Don t block the air outlet, and the required distance around should be at least 30cm. (See Fig.7) Should not be installed in dry cleaner. Socket wiring should be in accordance with the local electric safety requirements. Introduction to Exhaust Hose Installation Temporary installation Twist both ends of the exhaust hose into the square fixing clip and the flat fixing clip. Insert the square fixing clip into openings at back of the air conditioner (see Fig.8). Put the other end of the exhaust hose to the near windowsill. FIG. 7 FIG. 8 30 cm 30 cm 11 12 Drain Hose

INSTALLATION EXPLANATIONS Window Slider Kit Installation The installation manner of window slider kit is mostly in horizontal and vertical, No much difference in actual process. As shown Fig. 9 and Fig. 9a, check the min. and max. size of the window. Internal Tank Water Full Alarm Function The inner water tank in the air-conditioner has one water level safety switches, it controls water level. When water level reaches an anticipated height, the water full indicator lamp lights up. (If water pump is damaged, when the water is full, please remove the rubber blockage at the bottom of unit, and all water will drain outside.) FIG. 9 MAINTENANCE EXPLANATIONS Declaration: 1) Before cleaning, be sure to disconnect the unit from any electric supply outlet; 2) Do not use gasoline or other chemicals to clean the unit; 3) Do not wash the unit directly; 4) If the conditioner is damaged, please contact the dealer or repair shop. Air Filter If the air filter becomes clogged with dust/dirt, the air filter should be cleaned once every two weeks. Dismounting Open the air inlet grille and take off air filter. Cleaning Clean the air filter with neural detergent in lukewarm (104 F0) and dry it up in the shade. Mounting Putting the air filter into the inlet grille, replace the components as they were. Clean the Air-conditioner Surface First clean the surface with a neutral detergent and wet cloth, and then wipe it with a dry cloth FIG. 9a 13 14

TROUBLESHOOTING Troubles Possible Causes Suggested Remedies 1. UNIT DOES NOT START WHEN PRESSING ON/OFF BUTTON 2. Not cool enough Water full indicator lamp blinks, and water tank is full. Room temperature is higher than the setting temperature. (Electric heating mode) Room temperature is lower than the setting temperature. (Cooling mode) The doors or windows are not closed. There are heat sources inside the room. Exhaust air hose is not connected or blocked. Temperature setting is too high. Air inlet is blocked. Dump the water out of the water tank. Reset the temperature Reset the temperature Make sure all the windows and doors are closed. Remove the heat sources if possible Connect or clean the exhaust air hose. Reset the temperature Clean the air inlet. TROUBLESHOOTING CONT. Troubles Possible Causes Suggested Remedies 3. Auto Power-Off in heating mode Heating protection, when the temperature at the air outlet exceeds 158 F0, the unit will power off automatically. 4. Noisy The ground is not level or not flat enough The sound comes from the flowing of the refrigerant inside the air conditioner 5. E0 Code Room temperature sensor failed Restart the unit at enough lower room temperature. Place the unit on a flat, level ground if possible It is normal. Replace room temperature sensor (the unit can also work without replacement.) 6. E2 /E4 Code Water tank full Please empty the water tank. 15 16

TECHNICAL SPECIFICATIONS Description of Product Cooling Capacity (Btu) Heating Capacity (Btu) Voltage/Frequency Input Power Operating Sound Level Timer Coolant NS-8W-AC NS-10W-AC 8000/10000 BTU 8000/10000 BTU 115V / 60Hz 860W/1050W 52dB 24 hours R410 A Dimensions 13 x 11 x 26.75 Net Weight 44.5 lb/47.41 lb Electrical waste products should not be disposed of with household waste. Please recycle where facilities exist. Check with your local authority or retailer for recycling advice. Repairs must be carried out by authorized specialists to ensure electrical safety. Please contact the service agent or a suitably qualified electrician. Improper repairs could lead to danger. The warranty does not cover damage or failure that results from alteration, accident, misuse, abuse, neglect or improper maintenance. Due to ongoing product development we reserve the right to change the product specifications and documentation without notice. For more information: ENERGYWISE SOLUTIONS PO BOX 4681 LOGAN, UT 84323 877-891-7333 northstorm.com NORTH STORM 17