SYSTIMAX 360 Low-Profile, Stackable Splice Tray Kit Instructions

Similar documents
Fiber Optic Connector Cleaning and Inspection Kit Instructions

OPTICOM Fiber Optic Splice Module

SECTION COMMUNICATIONS FIBER CABINETS, ADAPTERS AND CONNECTORS

Carbon Rack Enclosure

The FTA-02 Fiber Arranger

Dome Fiber Optic Closure SC-221

Important Safety Notice

20-GALLON MOBILE PARTS WASHER OWNER S MANUAL

OWL. Laser OWL Series. Operations Guide. Singlemode Light Sources. Optical Wavelength Laboratories. Date: October 1, 2015

HR150 SERIES DEHYDRATOR USER MANUAL

Qualified Partner Programme QPP. Field-termination of FO connectors Felice Guarna

User Guide. T-25S-L (Coating Clamp) T-25U-L (Coating Clamp)

Fiber Optic Products Catalog

Installation Instructions

CLEANCUT CONVERTIBLE INSTALLATION GUIDE

ACQUITY UPLC HT Column Heater Instructions

ECP OPTICAL FIBRE SPLICING, TESTING AND COMMISSIONING REQUIREMENTS

Installation Instructions

SECTION COMMUNICATIONS OPTICAL FIBER BACKBONE CABLING

Fiber Optic and CAT 5, 6, 7 and 8 Installer Premise Cabling

BK AND BKT BLOWER ACCESSORY INSTALLATION INSTRUCTIONS

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)

Cleaning Instructions for Symbol IP54 Devices

ASSEMBLY AND DRESSING INSTRUCTIONS

BQ-260/260L. Important Information BOOK BINDER

Fiber Optics for Todays Industry Applications

Connector Maintenance

TOYOTA SIENNA MY LOWER DOOR MOLDING Preparation

SOVEREIGN W Grass Trimmer (Model: GT2317) Instruction Manual. Important - Please read these instructions fully before starting assembly

TOYOTA SIENNA MY LOWER DOOR MOLDING Preparation

WARNING: ELECTRICAL GROUNDING INSTRUCTIONS

Field Test Procedure for Optical Fibre Link Measurements

RLH Industries, Inc. Cleaning and Testing Fiber Optic Cable. Reference Guide MD A 0507

FOREWORD. Only 3 connector parts makes the assembly process both simple and efficient. CONTENTS. 1. Preparation and tools required for assembly

MNEFDD54 & MNBCDD54 GALVANIZED WALL FANS Installation, Operation, and Maintenance Instructions

Accessories. Safety Warnings. Table of Contents

600 SERIES LATERAL AND SHELF FILE LABEL HOLDER

Hand Chain (Model FCF) &

Reference Guide 2.1. Certificate Number

NG4access ODF Platform Standard Chassis Installation Manual

3 Scotch Mini-Weld Adhesive System User s Manual

Snapshot. User Manual. Use on Dimmer Outdoor Use Sound Activated DMX Master/Slave Voltage Switch Replaceable Fuse User Serviceable Duty Cycle

Bob-White Systems: AUTOMATED BOTTLE FILLER

CLEANCUT ULTRA-LOW INSTALLATION GUIDE

TRUSTY PRODUCTS, INC.

USSC LLC 4 ONE LLC FIELD MODIFICATION INSTRUCTIONS

AOYUE AOYUE. Soldering Station. Soldering Station. Instruction Manual. Instruction Manual

M Series Fan Filter Units

LASER SAFETY BARRIER

LASER SAFETY. Class 2 and 2a - low power, low risk Class 2 and 2a lasers have low power and emit visible light. They will cause harm if viewed

ProStar Ceiling Fan PS52. Installation Instructions Instrucciones de instalación Instructions d installation

3M Crimplok + Connector 8700-UPC & APC SM SC 900 µm

Surge Protective Devices Installation, Operation and Maintenance Manual. LowProfile Series: 080 and 120

FTTHARCFUSIONSPLICER AD620

Ceiling Fan Ow n e r s Manual

FOR THE FOLLOWING MODELS : EE-7588R EE-7588W EE-7588O EE-7588B EE-7588M

CEILING FAN OWNER S MANUAL

XAGA 550/550-L. Aerial Splice Closure. 1. General Description. 2. Warnings. 3. Cautions

Owner s Guide and Installation Manual

Instructions for Use: Fiberscope and LED Light Source

3.5-GALLON PARTS WASHER OWNER S MANUAL

Technical Publication

TA-12/HT12 Tabber. OPERATING GUIDE Revised:

Heater Upgrade Instructions

INSTALLATION INSTRUCTIONS

OWNER S MANUAL WISTERIA

MODEL 7000 SUCTION UNIT

Mariner Microspray and Low-Flow Electrospray Fused Silica Spray Tip and Capillary Kit. Operating Instructions. 1 Product Description.

2.5mm CLEANCLICKER 750 Fiber Optic Cleaner Performance Verification Report OptiTap-Style Connectors

OPERATOR S MANUAL. AIRgrip MultiTASKit

TOYOTA RAV BODY SIDE MOLDING Section I - Installation Preparation

OWNERS MANUAL. Minikote EZ

MAR 10 Rev C

MOST EFFECTIVE METHOD FOR WIPING A FIBRE

SuperKlean Washdown Products

ULTRAMAX GOLD UMX REMOTE LAMP AIR DISINFECTION SYSTEMS w/ ODOR REDUCING TECHNOLOGY (PCO) OWNERS GUIDE

CEILING FAN OWNER S MANUAL

Model CWA200 Owner s Manual

Cleaning the internal optics surfaces

MANUAL RESET ALARM RELEASE

EAGLE 2000B EAGLE 2000BE EAGLE 2000EBT MUST READ MANUAL PRIOR TO INSTALLING MACHINE

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

INSTALLATION. Glass Panel Doors (select models) CAUTION

Cable Drum Machine. Operation Manual 110ES SERIES. Cleans 1 1/4" to 3" lines up to 25'

MANUAL RESET ALARM RELEASE

installation and operation manual for Hunter Ceiling Fans

Hands-On CAT 5/6 & Fiber Optic Installer

CEILING FAN OWNER'S MANUAL

INSTALLATION & OPERATING INSTRUCTIONS

INSTRUCTION MANUAL MODEL: 690E

owner s manual produitsneptune.com Do not discard. Save these instructions for further use.

Thermal Stripper, TSAB-40 User Manual

Installation. Built-in Full Height Wine Cellar VCWB301

G155PU001S. Pigtailed 14-PIN DIL Laser Diode with TEC. FLMS Min. Typ. Max.

Owner s Guide and Installation Manual


Installation Guide. Model: IC15- MF Model: IC15- MFSilent Model: IC30- MF Model: IC30- MFSilent

SERVICE REQUIREMENTS

18 INCHES, OSCILLATING STAND FAN

Table of Contents What to Expect with Your Installation. Top Housing. Ceiling Plate. Tools Needed.

Transcription:

Instruction Sheet 860506468 Issue 2, December 2012 SYSTIMAX Solutions SYSTIMAX 360 Low-Profile, Stackable Splice Tray Kit Instructions General The SYSTIMAX 360 LP-STACK-SPT stackable splice tray is 14 inch wide x ½ inch high x 6 ½ inch deep (356mm x 13mm x 165mm) and can store 48 single fusion splice sleeves. The tray is compatible with Fujikura FP-03 series, Furakawa S921 and S922 or Uniprise SFE (9701008/00) single fusion splices only. The tray features numerous fiber entry and exit ports and offers multiple buffer tube restraining points for maximum flexibility of installation. The clear plastic top cover may be snapped on to protect the routed fiber and splices while providing optimum visibility for inspection. Multiple trays may be stacked and snapped together using provided plastic hardware, or fastened together with customer provided hardware using holes provided on base of tray. This product is intended for indoor use or can be used outdoors in a suitable protective enclosure. Ordering information is listed below: Material ID Part No. Description 760148502 LP-STACK-SPT 360 low-profile stackable splice tray SYSTIMAX 360 Fusion Splice Tray (Shown with Cover Installed) 2012 CommScope, Inc. All rights reserved For RoHS Inquiries: CommScope Inc. Corke Abbey, Bray Co. Dublin, Ireland Attn: Legal Department Page 1 of 6

860506468 Instruction Sheet How to Contact Us To find out more about CommScope products, visit us on the web at http:/// For technical assistance: Parts List - Within the United States, contact your local account representative or technical support at 1-800-344-0223. Outside the United States, contact your local account representative or Authorized Business Partner. - Within the United States, report any missing/damaged parts or any other issues to CommScope Customer Claims at 1-866-539-2795. Outside the United States, contact your local account representative or Authorized Business Partner. Verify parts against the parts list below: Quantity Description 1 Splice tray assembly 1 Top cover 4 Snap rivet plungers 4 Snap rivet grommets 2 Millie-Ties 4 Cable Ties Materials Required Alcohol (IPA) Lint-free wipes Cautions Disconnected optical components may emit invisible optical radiation that can damage your eyes. Never look directly into an optical component that may have a laser coupled to it. Serious and permanent retinal damage is possible. If accidental exposure to laser radiation is suspected, consult a physician for an eye examination. Wearing safety glasses during installation of this shelf is recommended. Although standard safety glasses provide no protection from potential optical radiation, they offer protection from accidental airborne hardware and cleaning solvents. Page 2 of 6

860506468 Issue 2, December 2012 Splice Tray Features Fiber retention gate (2 positions) Hole provided for plastic hardware Fiber entry/exit openings (8 positions) Cover retention snaps (6 positions) External bu ffer tube tie-down points (6 positions) Hole provided for optional mounting scheme Splice sleeve holders (2 Positions) Buffer tube tie-down rail Retention slots (6 positions) Top cover Snap rivet grommet Snap rivet plunger Note: Snap rivet grommets and plungers are not used for single-tray installations. Page 3 of 6

860506468 Instruction Sheet Step 1 Build Up Tray Shelf OSP cable Equipment rail Buffer tube Work surface Splice tray Buffer tube Cable tie Splice sleeve Pigtails WARNING Take proper precautions to avoid damaging fiber while routing into shelf and splice tray. Note: It is strongly advised that splice trays be built up on a work surface (e.g. a table, as shown above) outside of shelf especially if multiple trays are to be stacked. This will insure that sufficient buffer tube slack length is available for temporary tray relocation if subsequent splice repairs are required. It is important for all buffer tubes to be approximately the same length and to enter shelf in the same location to facilitate manageable spooling of slack loop into shelf for tray installation. Keep buffer tubes on rearward-facing side of splice tray so as to keep patchcord exit ports as unobstructed as possible. Use cable ties provided to restrain buffer tubes to tie-down rails on tray. Tray is designed for 3mm and 4mm buffer tube diameters. Larger diameter tubes may have to be trimmed back before tray entry, if density is prohibitive. Page 4 of 6

860506468 Issue 2, December 2012 Splice tray is sized to contain up to 1 meter (39 ) each of pigtail fiber and fiber from the OSP cable. 40mm splice protector sleeves are recommended when using 900 micron fiber from OSP cable. As tray fills up with fiber, it may become difficult to maintain proper bend radii at splices when using 60mm sleeves. Install splice sleeves into lower position of holders by firmly pressing them down into retention features with 2 index fingers. One finger is sufficient for placing sleeves into the upper (stacked) position. Use and orange stick or similar device to remove sleeves for repairs. Press down on holder to support it when removing a splice sleeve. Wind patchcord groups in opposite directions (clockwise & counter-clockwise) inside tray to keep lengths exiting tray consistent for better dressing at termination. Use Millie-ties to bundle and restrain pigtails, as required. Step 2 Install Tray into Shelf Buffer tube slack loop Terminate pigtails 1. Use isopropyl alcohol (IPA) and lint-free wipes to clean floor of shelf. 2. Gently, lift and position tray and fiber as desired (UHD positioning is shown above) into shelf. Remove paper backing from splice tray and press down on tray firmly at several locations around its perimeter to insure that adhesive contacts shelf surface as desired. 3. Spool buffer tube slack behind tray and use cable ties to attach it at the external buffer tube tie-down points as required. 4. Terminate pigtails into adapters. 5. Remove protective plastic film from both sides and install top cover by pressing it down onto 6 snap features on holders. It is easiest to start at center locations and work out. Note: Top cover removal is accomplished by depressing snap features one at a time and lifting up on the cover. Use of finger nails or an orange stick (or similar device) is recommended. Note: Splice tray has an adhesive backing for attachment to shelf floor. Remove paper backing to expose. Leave backing in place on all additional trays when used in a stacked configuration. If additional trays are to be used, proceed to Step 3. Page 5 of 6

860506468 Instruction Sheet Step 3 Building Up and Stacking Trays Top cover Snap rivet plunger 3-tray stack Snap rivet grommet 1. Align 4 holes on base (provided for plastic hardware) with 4 holes on elevated platforms of previous tray. Additional trays must be rotated 180 from the previous tray orientation. 2. Install snap rivet grommets and plungers. 3. Install top cover. 4. Repeat as required. Note: Three trays may be used in a 1U shelf for a total of 144 fusion splices. Six trays may be used in a 2U shelf for a total of 288 fusion splices and twelve trays may be used in a 4U shelf for a total of 576 fusion splices. Page 6 of 6