Membrane Air Dryer IDG30 A IDG50 A IDG60LA,IDG60SA IDG75LA,IDG75SA IDG100LA,IDG100SA

Similar documents
Membrane Air Dryer IDG10,IDG10H IDG20,IDG20H

Moisture Control Tube

Prevents condensation

Cost reduced by up to. 21,060 yen/year! Purge air flow rate (rated conditions) Running cost (yen/year) 46,440. Model IDG50A. Existing model 67,500

Membrane Air Dryer. Dew point indicator. Fitting to exhaust purge air for dew point checker. Purge air discharge fitting for dehumidification

Refrigerated Air Dryer

Refrigerated Air Dryer

Refrigerated Air Dryer

Refrigerated Air Dryers

Cost reduced by up to /year! Purge air flow rate (rated conditions) Running cost [ /year] Model IDG50A

Cost reduced by up to. 21,060 yen/year! Purge air flow rate (rated conditions) Running cost (yen/year) 46,440. Model IDG50A. Existing model 67,500

Refrigerated Air Dryer Large Size Series

Multistage Ejector MODEL / Series / Product Number

Cost reduced by up to 21,060. Purge air flow rate (rated conditions) Running cost (yen/year) Model 46,440 IDG50A. Current model 67,500.

TUBE DRYERS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution TUBE DRYERS

Low dew point type. Discrete standard dew point type (SD3015-B) (SD3035-B) (SD3050-B) (SD3075/4050-B) (SD4075-B) (SD4100-B) (SD3015-A)

Drain Separator for Vacuum

Medium main line filter

MEMBRANE AIR DRYERS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution MEMBRANE AIR DRYERS

Pressure Switches Precautions 1 Be sure to read this before handling.

Refrigerated Air Dryer

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)

Space Saving Vacuum Ejector Vacuum Pump System MODEL / Series / Product Number

Vacuum system component SELVACS

Air filter. Components for air preparation and pressure adjustment / main line unit CONTENTS. Medium main line filter. Large main line filter

Hollow Fiber Membrane Filter Type Air Dryer with Built-in Push-In Fitting

Hollow Fiber Membrane Filter Type Air Drier Unit Type

INSTRUCTION MANUAL W-400

Electron Microscopy Sciences

Reducing Valve Direct Mount Type with Pressure Gauge. Direct Mount Type (Compact size) Pressure Gauge is selectable.

Prevents! Moisture Control Tube. Diffuses water vapor in the piping to the outside! Series IDK

Valve timing. Atmospheric air

AUC Cell Washer. User Manual

USE and MAINTENANCE INSTRUCTION MANUAL GRAVITY. WS-400 EVO LS-400 Entech. SPRAY GUN Series. en it fr es pt de se

Chapter 9: The basics of air preparation

Vacuum Saving Valve. ZP2V Series. With One-touch fitting type available!

JT-SB116JH-G-NA JT-SB116JH-W-NA

Ioniser Nozzle type. Ion balance ±10 v. Slim design: Thickness dimension 16 mm RoHS compliant. Series IZN10

Refrigeration air dryer

Filter for Drain and Dust (Filtering Accuracy: 5µm) Optional Selection of Direct Mount Pressure Gauge (Compact size).

IAQ_100 C Package

Organic Solvent Recovery Unit RT200. Instruction Manual. - First Edition -

Document No. IZ*-OMP0064 C. P r o d u c t Ionizer. Model/Series. IZS4 Series

Operating manual ELECTRIC ASPIRATOR 00) : 1) Page 1

Installation and Maintenance Manual Forbes Marshall Tracer Line Trap FMMST63

INSTRUCTION MANUAL CLEAN BELLOWS TYPE INDUSTRIAL ROBOT SPECIFICATIONS. Notice

P3X Series Membrane dryers

% by up ctoond re-heater and

TECHNICAL NOTE. Response Factors for Flame Ionization Detector Operation FLAME IONIZATION DETECTOR OPERATION BASICS

Monitored Pneumatic Valves On Series Ported Manifold

INDEX. Air flow capacity SCFM (m 3 /h [ANR]) Model Outlet air pressure dew point Note) 37 F (2.8 C) 45 F (7.2 C) 50 F (10 C)

With air temperature adjustment function. Application example. with constant conditions to air bearings mounted on the tool. Compressed.

NGD8800 USER S MANUAL

SEFA 8 CERTIFICATE OF PERFORMANCE INDEPENDENT TEST LAB LABORATORY FURNITURE - SEFA 8 DESCRIPTION OF TEST CABINET WHAT IS SEFA?

½ Monitored Pneumatic Valves On Series Ported Manifold

Refrigeration Dryers WDRD

DUCTED AIR CONDITIONER. Owner s Manual. KD Series KD24. Kaden Owner s Manual 1

Hazardous area descriptions

Brazed Plate Heat Exchanger Instruction Manual for BX Series

FUTURE AIR SOLUTIONS OIL FREE SCROLL COMPRESSORS

Introducing the high-speed cyclone type drain separator!

Warning Caution. Safety Precautions (Be sure to read these precautions before using our products.)

How to Order. Combination of supply valve. Light/Surge voltage suppressor. Electrical entry. and release valve Pilot valve. Voltage 5 L Z E C.

Filter and Regulator Combination Unit Series

Owner s Manual TABLE OF CONTENTS

Utopian Split A/C. Thank you for purchasing this quality Split A/C system!

THERMAL SYSTEMS, INC. Installation and Operation Manual

Owner's Manual TABLE OF CONTENTS

Owner s Information Manual

PAR-KUT INTERNATIONAL

CMMD Series Membrane Air Dryer

Vacuum unit ideal for controlling large flow rates Vacuum unit VSQ/VSQP series

External Vacuum Controller with compact and lightweight body, achieving shorter blow-off time. External Vacuum Controller Series

AOYG18LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL. For authorized service personnel only. PART NO

Handling or using the product improperly and in disregard of the instructions with this mark might result in serious bodily injury or death.

½ Monitored Pneumatic Valve Patented Technology

Bosch Split-Type Ductless Air Conditioner / Heat Pump

Prevents condensation

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

CF1400 DO NOT RETURN PRODUCT TO PLACE OF PURCHASE. IF YOU HAVE ANY QUESTIONS, CALL OUR TOLL FREE HOTLINE:

AMG Model (1) Port size (Nominal size B) Weight (kg) 1 /8, 1 /4, 3 /8 1 /4, 3 /8, 1 /2 3 /8, 1 /2, 3 /4. Specifications

User s Information Manual

Owner s Manual Super-Slim Four-Way Cassette

ZEN MIRROR. Install / Operating Manual. Table of Contents

DAIKIN's Experience in the production with R32

Model OP155 Air Dryer

Inverter Split-type Room Air Conditioner

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

VRA2000 Series Port size: Rc1/4, Rc3/8, G1/4, G3/4, 1/4NPT, 3/8NPT

Precisely control the temperature of the circulating fluid by using the Peltier device. Refrigerant-free and environmentally friendly.

No.THD51E To prevent accidents arising from the use of this product, please ensure the operator using it receives this manual.

Industrial Refrigeration. Brochure R/S CB 02/10

WINDOW TYPE COOLING MODEL AKT7F AKT9F REVERSE CYCLE MODEL AKT7U AKT9U FUJITSU GENERAL LIMITED

MC Series Gas-Fired Heating Appliance

High Inlet Temperature Air Dryer. Desiccant Air Dryer. Membrane Air Dryer After-Clooler. Air Filter. Oil-Water Separator Automatic Drain Value

KSD-35 DR11 KUE-35 DVN11

Elite. User s Information Manual. Elite and Elite VWH* All Models

Owner s Information Manual

Chemical Thermo-con. How to Order. Communication A RS-485 B RS-232C. Power supply 2 Single-phase: 180 to 242 VAC 50/60 Hz.

Transcription:

Doc. No. AMX-OM-Q014 PRODUCT NAME Membrane Air Dryer MODEL / Series / Product Number IDG30 A IDG50 A IDG60LA,IDG60SA IDG75LA,IDG75SA IDG100LA,IDG100SA Contents 1. Safety Instructions 1 2. Installations and Operations 3 3. Maintenances and Checks 5 4. Specifications 6

1. Safety Instrutions Membrane Air Dryer Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of, Warning or Danger. They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC) *1), and other safety regulations. *1) ISO 4414: Pneumatic fluid power -- General rules relating to systems. ISO 4413: Hydraulic fluid power -- General rules relating to systems. IEC 60204-1: Safety of machinery -- Electrical equipment of machines.(part 1: General requirements) ISO 10218-1992: Manipulating industrial robots -Safety. etc. Warning Danger indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Warning 1. The compatibility of the product is the responsibility of the person who designs the equipment or decides its specifications. Since the product specified here is used under various operating, its compatibility with specific equipment must be decided by the person who designs the equipment or decides its specifications based on necessary analysis and test results. The expected performance and safety assurance of the equipment will be the responsibility of the person who has determined its compatibility with the product. This person should also continuously review all specifications of the product referring to its latest catalog information, with a view to giving due consideration to any possibility of equipment failure when configuring the equipment. 2. Only personnel with appropriate training should operate machinery and equipment. The product specified here may become unsafe if handled incorrectly. The assembly, operation and maintenance of machines or equipment including our products must be performed by an operator who is appropriately trained and experienced. 3. Do not service or attempt to remove product and machinery/equipment until safety is confirmed. 1.The inspection and maintenance of machinery/equipment should only be performed after measures to prevent falling or runaway of the driven objects have been confirmed. 2.When the product is to be removed, confirm that the safety measures as mentioned above are implementedand the power from any appropriate source is cut, and read and understand the specific product precautions of all relevant products carefully. 3. Before machinery/equipment is restarted, take measures to prevent unexpected operation and malfunction. 4. Contact SMC beforehand and take special consideration of safety measures if the product is to be used in any of the following. 1. Conditions and environments outside of the given specifications, or use outdoors or in a place exposed to direct sunlight. 2. Installation on equipment in conjunction with atomic energy, railways, air navigation, space, shipping, vehicles, military, medical treatment, combustion and recreation, or equipment in contact with food and beverages, emergency stop circuits, clutch and brake circuits in press applications, safety equipment or other applications unsuitable for the standard specifications described in the product catalog. 3. An application which could have negative effects on people, property, or animals requiring special safety analysis. 4.Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical protective function, and periodical checks to confirm proper operation. -1-

1. Safety Instructions Membrane Air Dryer Safety Instructions 1. The product is provided for use in manufacturing industries. The product herein described is basically provided for peaceful use in manufacturing industries. If considering using the product in other industries, consult SMC beforehand and exchange specifications or a contract if necessary. If anything is unclear, contact your nearest sales branch. Limited warranty and Disclaimer/Compliance Requirements The product used is subject to the following Limited warranty and Disclaimer and Compliance Requirements. Read and accept them before using the product. Limited warranty and Disclaimer 1. The warranty period of the product is 1 year in service or 1.5 years after the product is delivered, whichever is first. 2) Also, the product may have specified durability, running distance or replacement parts. Please consult your nearest sales branch. 2. For any failure or damage reported within the warranty period which is clearly our responsibility, a replacement product or necessary parts will be provided. This limited warranty applies only to our product independently, and not to any other damage incurred due to the failure of the product. 3. Prior to using SMC products, please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products. 2) Vacuum pads are excluded from this 1 year warranty. A vacuum pad is a consumable part, so it is warranted for a year after it is delivered.also, even within the warranty period, the wear of a product due to the use of the vacuum pad or failure due to the deterioration of rubber material are not covered by the limited warranty. Compliance Requirements 1. The use of SMC products with production equipment for the manufacture of weapons of mass destruction (WMD) or any other weapon is strictly prohibited. 2. The exports of SMC products or technology from one country to another are governed by the relevant security laws and regulations of the countries involved in the transaction. Prior to the shipment of a SMC product to another country, assure that all local rules governing that export are known and followed. 1. SMC products are not intended for use as instruments for legal metrology. Measurement instruments that SMC manufactures or sells have not been qualified by type approval tests relevant to the metrology (measurement) laws of each country. Therefore, SMC products cannot be used for business or certification ordained by the metrology (Measurement) laws of each country. -2-

2. Installations and Operations 2. Installations and Operations: Design a. Depending on the model and operating, the oxygen ratio of the outlet air may drop below the prescribed standard. Do not use standard dew point -40oC (symbol L) type, standard dew point -60oC (symbol S) type and IDG30A, 50A, 30HA, 50HA for dehumidifying breathing air. Do not use only outlet air (dry air ) in a closed room. b. Devise a layout which considers the position of the purge air discharge ports. Purge air is humid air. Devise a layout in which the humid purge air will not cause corrosion or malfunction of peripheral equipment. c. When very clean air is required (Supplying clean air to air bearings, blowing of semiconductor parts, etc.) Install a micro mist separator or Super Mist Separator on the outlet side of this equipment. Grease is applied inside of the Regulator used in the V type unit. When air with high purity is required, please either mount the Super Mist Separator on the outlet side or use a made-to-order product, which is provided with a Micro Mist Separator (Series AWD) instead of a Regulator. d. Time to reach the rated dew point A certain amount of time is required to achieve the rated dew point after the air begins flowing into the membrane air dryer. Use the times below as a guide, and begin operating the outlet side equipment after the rated dew point is achieved. Standard dew point -20 o C, -15 o C : about 10 min. Standard dew point -40 o C : about 30 min.* Standard dew point -60 o C : about 60 min.* * This time can be shortened as described below. 1) Provide a valve on the outlet side of the membrane air dryer. 2) Supply air with the valve closed so that only purge air flows through the membrane air dryer. 3) After 15 minutes or more, open the valve and let air flow to the outlet side equipment. Selection a. Consider the purge air flow rate in total flow rate requirements. Find the purge air flow rate from the charts and calculate the required outlet air flow rate + purge air flow rate. The air supply capacity must be at lease equal to the calculated flow or the required outlet air flow rate cannot be obtained. b. Use the proper size tubing for purge air discharge () The dehumidification capacity decreases in proportion to the length of the tubing for discharging purge air. Use tubing of the specified size and keep its length to 5 meters or less. -3- Mounting a. Do not obstruct the purge air discharge ports. Dehumidification performance will decrease or may become impossible if purge air back pressure becomes too high or purge air stops flowing. b. Provide proper filtration on the inlet side of a membrane air dryer. Performance will be reduced If the inlet air contains oil, water, or other contaminations that can clog the membrane pores. Install an AFM Mist Separator or an AMH Micro Mist Separator with Pre-filter on the inlet side of membrane dryer. Install an air filter or main line filter on the inlet side of the mist separator when there are large quantities of dust (solid foreign matter). An AFM Mist Separator and AFD Micro Mist Separator or an AMH Micro Mist Separator with Pre-filter are already installed on the M and V unit types. c. Remove water droplets from the inlet air Water droplets in the air can lower performance and cause malfunction. d. Large quantities of dust (solid foreign matter) are contained in the supply air. When there are large quantities of dust (solid foreign matter), install an air filter or main line filter to the inlet side of the mist separator. e. Install a regulator on the outlet side of the membrane air dryer. Dehumidification performance will be reduced if a regulator is a regulator is installed on the inlet side of the membrane dryer. f. Ensure that intermittent pressure is not applied to the product. Do not frequently operate a solenoid valve on the inlet side. The membrane dryer can be damaged if inlet pressure is applied intermittently. g. Installation of Bracket Assembly (Accessory). Please attach by a customer.. Tightening torque : 1.4 N m Hexagon key : nominal 4 Dew point checker Air inlet port * Outlet port in case of Option R Front Body Holder Case Back Fig 2.1 Names of parts (Example: IDG30 A) Plug * Please do not remove Purge air outlet port

2. Installations and Operations 2. Installations and Operations: Piping Warning a. Confirm locking of case and body When using in a unit, be sure to set the air pressure to zero before using a Mist Separator or Micro Mist Separator with modular connections. Also, confirm that the body and case are locked together with a click before starting the flow of compressed air. b. Confirm tightening of the holder. Before starting the flow of compressed air, turn the Membrane air dryer s holder in its tightening direction, confirming that it is completely tightened and that the case will not come off. c. Exhaust the purged air discharge () The piping of purge air for dehumidification and for the dew point checker can be combined, but do not combine it with compressed air lines or drain piping or merge the purge air with exhaust air from other equipment. Back-pressure through the purged air exhaust port can cause damage or poor performance. a. Use of tools Hold the upper portion of the body (aluminum die-casted section) with a spanner or adjustable angle wrench. Do not turn it while holding the case section. b. Drain piping for separators Use a tube of the prescribed size and keep the length within 5 meters or less when installing drain piping for Mist Separators or Micro Mist Separators. Be sure that the tube does not rise up or become folded over. c. Flush pipes before installation. Use an air blower to flush the piping to thoroughly remove any cutting chips, cutting oil, or debris from the piping inside, before connecting them. If they enter the inside of products, they could cause products to malfunction, lower performance or damage the element. d. Piping materials for low dew point air Do not use nylon tube piping and resin fittings (except fluoropolymer) for the outlet side of the membrane air dryer if air of a low dew point (40 o C or less) is required, Due to the nature of the nylon tube, it could be affected by the ambient air, and it might not be possible to achieve the prescribed low dew point at the end of the tube. For low dew point air, use stainless steel or fluoropolymer piping. Air Supply a. Compressed air supply capacity An air source that has a supply capacity that is larger than the necessary outlet air flow rate (dry air flow rate) + purge air flow rate is required. See the purge air flow rate diagram in the catalog for the purge air flow rate. b. Avoid chemical substances which have an adverse effect on the product The chemical substances stated in the table below can reduce the performance or damage the membrane element. Do not use the membrane dryer in an environment containing these chemicals substances. Type Harmful Substances Solvent Acetone, Benzene, Phenol, Toluene, Trichloroethylene, Xylene, Cresol, Thinner, Aniline, Chloroform, Ethyl Alcohol, Methyl Alcohol, Chlorobenzene, Trichloroethane, Ethylbenzene, Isopropyl Alcohol, Dioxane, Tetrahydrofuran, Methyl Chloride, Cyclohexanone, Carbon Tetrachloride, Methyl Ketone, Ethyl Ketone, etc. Acid Sulfuric Acid, Nitric Acid, Hydrochloric Acid, Acetic Acid, Lactic Acid, Chromic Acid, etc. Gas Chlorine, Sulfurous Acid, Hydrogen Sulfide, Bromine, Ozone, Ammonia, etc. Oil Hydraulic Fluid (Phosphoric Ester), Fuel Oil, Water Soluble Cutting Fluid (Alkaline), Kerosene, etc. Strong Lithium hydroxide, Sodium hydroxide, Bases Potassium hydroxide, Calcium hydroxide, etc. Others Anaerobic thread lockers Operating Environment a. Do not use at temperatures (fluid or ambient temperatures) higher than the prescribed operating. Resin is used in the membrane module (element), and it can be damaged by operation at high temperatures. confirm that the fluid temperature does not exceed the membrane dryer s range of operating during use, especially when installed immediately after a reciprocating type air compressor. b. Keep the inlet air temperature lower than the ambient temperature. Condensation and water drops may accumulate inside of the membrane dryer s body and reduce its dehumidification capacity if the membrane air dryer s body is cooled by the ambient air. -4-

3. Maintenances and Checks 3. Maintenances and Checks Ensure the product is not pressurized before maintenance. Check Point 3-1. Checks for Air Filters a. Check that condensation is discharged normally from the filter separator on the inlet. b. Check that there are no cracks, scratches or other deterioration on the resin case. c. Clean resin case of any dirt with neutral detergent regularly, or if necessary replace with a new resin case. d. The replacement interval for the elements is when the pressure drop reaches 0.1 MPa, or after two years of operation, whichever comes first. 3-2. Checks for Membrane Air Dryer a. Confirming the dehumidification function with the dew point indicator Confirm normal performance of membrane air dryer by color of grains inside the dew point checker. Condition Color of Dew point checker Default White, Pink Normal Operating Blue Bad condition White, Pink, Brown, Black If humid air flowing in turns the color pink, and then if dry air enters, the color turns back to blue. It takes about 1 hour from the start of air flow for the dew point indicator color to change. b. Membrane module (Element) replacement period Replace the membrane module (Element) when the color of the dew point indicator turns white or pink. As a guideline, unit should be replaced after 10 years of use (10 hours/day operation)approximately. Replace the element when the color of the dew point indicator turns white or pink, even if it is within the 10-year period. c. Dew point indicator replacement period In the dew point indicator an absorbent is used. This absorbent absorbs the gasified oil in the compressed air and/or the gaseous elements other than the air, and may then turn brown.when absorbent turned brown, replace the dew point indicator.besides, in the event of replacing them periodically, carry out after two-year operation as a guideline. Service Parts Table 3-1. Membrane Module Set (Element) and Dew Point Checker set Name Membrane Dew point module Checker set set IDG30A,30HA,30LA IDG-EL30A IDG50A,50HA,50LA IDG-EL50A IDG60LA,60SA IDG-EL60LA IDG-DP01 IDG75LA,75SA IDG-EL75LA IDG100LA,100SA IDG-EL100LA IDG30A,30HA,30LA IDG-EL30A IDG50A,50HA,50LA IDG-EL50A IDG60LA,60SA IDG-EL60LA IDG-DP01-X001 IDG75LA,75SA IDG-EL75LA IDG100LA,100SA IDG-EL100LA Table 3-2. Filter Element Assembly AFM40-A AFD40-A IDG30A,30HA,30LA IDG50A,50HA,50LA IDG60LA,60SA IDG75LA,75SA IDG100LA,100SA AFM40P-060AS AFD40P-060AS -5-

4. Specifications 4. Specifications 1) Units type (Unit M, Unit V) Component equipment Range of operating Mist separator Micro mist separator Regulator (Type V only) Spacer Fluid *Note1 *Note1 Standard Outlet air atmospheric Performanc pressure dew point o *Note2 C Inlet air flow rate L/min(ANR) Outlet air flow rate L/min(ANR) Purge air flow rate L/min(ANR) *Note3 Purge flow ratio Inlet air saturation temperature o C Dew point indicator purge air flow rate Regulator construction (about Type V) Port size Standard Performance Mass kg Specifications IDG30AM4 IDG50AM4 IDG30HAM4 IDG50HAM4 IDG30LAM4 IDG50LAM4 IDG30AV4 IDG50AV4 IDG30HAV4 IDG50HAV4 IDG30LAV4 IDG50LAV4 AFM40-A AFD40-A AR40 Y400(T)-A Compressed Air -20 0.3~1.0-15 -40 360 586 329 550 93 135 300 500 300 500 75 110 60 86 29 50 18 17% 15% 9% 9% 19% 19% 0.7 1 L/min (ANR) {In the case of inlet air pressure 0.7MPa} Relief type 1/4 3/8 Type M 1.8 1.9 1.8 1.9 1.8 1.9 Type V 2.4 2.5 2.4 2.5 2.4 2.5 Component equipment Range of operating Fluid *Note1 *Note1 Standard Performance Outlet air atmospheric pressure dew point o C *Note2 Inlet air flow rate L/min(ANR) Outlet air flow rate L/min(ANR) Purge air flow rate L/min(ANR) *Note3 Purge flow ratio Inlet air saturation temperature o C Dew point indicator purge air flow rate Standard Performance Regulator construction (about Type V) Port size Mist separator Micro mist separator Regulator (Type V only) Spacer Mass kg Specifications IDG60LAM4 IDG75LAM4 IDG100LAM4 IDG60SAM4 IDG75SAM4 IDG100SAM4 IDG60LAV4 IDG75LAV4 IDG100LAV4 IDG60SAV4 IDG75SAV4 IDG100SAV4 AFM40-A AFD40-A AR40 Y400(T)-A Compressed Air 0.3~1.0-40 -60 224 308 400 75 140 230 170 240 300 50 100 150 54 68 100 40 80 24% 22% % 33% 29% 35% 0.7 1 L/min (ANR) {In the case of inlet air pressure 0.7MPa} Relief type 3/8 1/2 Type M 2.6 2.8 2.9 2.6 2.8 2.9 Type V 3.1 3.3 3.4 3.1 3.3 3.4 * Note 1. When using the product in the temperature range between -5 and 5 deg. C, prevent water droplets from entering the inlet port. (No freezing of the fluid) * Note 2. ANR indicates the flow rate converted to the value at 20 deg. C, under the atmospheric pressure and the state of relative humidity 65%. * Note 3. Includes 1 L/min [ANR] of purge air flow (at 0.7 MPa inlet air pressure) for the dew point indicator. -6-

1) Single Units type Range of operating Fluid Inlet air pressure MPa Specifications IDG30A IDG50A IDG30HA IDG50HA IDG30LA IDG50LA *Note 1 *Note 1 Standard Outlet air atmospheric performance pressure dew point o C -20-15 -40 Inlet air flow rate L/min(ANR) *Note 2 360 586 329 550 93 135 Outlet air flow rate L/min(ANR) 300 500 300 500 75 110 Purge air flow rate L/min(ANR) *Note 3 60 86 29 50 18 Purge ratio % 17% 15% 9% 9% 19% 19% 0.7 Inlet air saturation temperature o C Dew point indicator purge air flow rate 1L/min (ANR) {In case of inlet air pressure 0.7 MPa} Standard performance Port size Mass kg (With bracket) Range of operating Standard performance Standard performance Fluid Inlet air pressure MPa Inlet air saturation temperature o C Dew point indicator purge air flow rate Port size Masst kg (With bracket) 0.78 (0.91) 0.81 (0.94) Compressed Air 0.78 (0.91) 0.3~1.0 1/4 3/8 0.81 (0.94) 0.78 (0.91) * Note 1. When using the product in the temperature range between -5 and 5 deg. C, prevent water droplets from entering the inlet port. (No freezing of the fluid) * Note 2. ANR indicates the flow rate converted to the value at 20 deg. C, under the atmospheric pressure and the state of relative humidity 65%. * Note 3. Includes 1 L/min [ANR] of purge air flow ( at 0.7 MPa inlet air pressure) for the dew point indicator. Revision history 0.8 (0.94) Specifications IDG60LA IDG75LA IDG100LA IDG60SA IDG75SA IDG100SA *Note 1 *Note 1 Outlet air atmospheric -40-60 pressure dew point o C Inlet air flow rate L/min(ANR) *Note 2 224 308 400 75 140 230 Outlet air flow rate L/min(ANR) 170 240 300 50 100 150 Purge air flow rate L/min(ANR) *Note 3 54 68 100 40 80 Purge ratio % 24% 22% % 33% 29% 35% 0.7 1.56 (1.71) 1.69 (1.84) Compressed Air 1.82 (1.97) 0.3~1.0 1 L/min (ANR){In case of inlet air pressure 0.7 Mpa} 3/8 1/2 1.56 (1.71) 1.69 (1.84) 1.82 (1.97) 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL http://www.smcworld.com Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 2013 SMC Corporation All Rights Reserved