AlorAir Solutions INC

Similar documents
Registrate by scanning. Add: North Carolina USA

Registrate by scanning. Storm Ultra. Add:Florida USA

DEHUMIDIFIERS. SuperDry 125. Installation and Operations Manual. WhiteWing Dehumidifiers. P: Add: 300 E Valley Drive, Bristol, VA 24201

Seaira Global LLC NC Highway 50 Surf City, NC

Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com

Registrate by scanning

AlorAir Solutions INC Add: Shoemaker Ave,Cerritos,CA90703 Tel:

IW-25-2 Dehumidifier Installation & Operations. Manual

Registrate by scanning. Add: North Carolina USA

Superdryer Dehumidifiers

WatchDog NXT60. Installation and Operations Manual. Seaira Global, LLC NC Highway 50 Surf City, NC (910)

Zeus Extreme Owner's Manual

11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions. Model No. PE4-11R Soleus Air International

12,000 BTU Evaporative Portable Air Conditioner

Portable Air Conditioner with Heat Pump Technology Operating Instructions. Model No.: HCB-P13HP-D. Reference No.: BPD13HP V140217

Model No.: PS08-01 PS10-01 Ref: KY80 KY100

Portable Air Conditioner with Heat Pump Technology PH4-10R-01, PH4-12R-01, & PH4-14R-01 Operating Instructions

Portable Air Conditioner, Dehumidifier,Heater and Fan utilizing Heat Pump Technology

Horizontal Bottle Cooler Installation and Operation Manual

Cleanshield HEPA 550 Owner's Manual

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

Instruction Manual Item No.: V~, 60Hz

5) Do not start or stop the unit by inserting or pulling out the power plug.

OPERATING INSTRUCTIONS

Model No. PE2-07R / PE2-09R / 9000 BTU Portable Air Conditioner with dehumidifier & Fan PE2-07R-62 / PE2-09R-32 Operating Instructions

14,000 BTU Portable Air Conditioner 14,200 BTU Heat Pump Model Number: LX-140 Operating Instructions. Model No. LX Soleus Air International


Operating Instructions

Portable Air Conditioner and Heater With Heat Pump Technology Operating Instructions. Model No.: PH3-12R-03 Reference No.: KY2-34

Portable Air Conditioner with Evaporative Technology PE6-10R-03 Operating Instructions. Model No. PE6-10R Soleus Air International

12,000 BTU Portable Air Conditioner PE3-12R-03. Model No. PE3-12R Soleus Air International

Glass Door Merchandisers GDC10, GDC12F, GDC15, GDC23, GDC24F, GDC40, GDC40F, GDS47, GDC69

Instruction Manual Item No.: V~, 60Hz

CR13000-PAC OWNER S MANUAL. Portable Air Conditioner. PORTABLE AIR CONDITIONER with HEAT PUMP. Operating and Servicing Instructions

EBAC MODEL KOMPACT INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

WHYNTER ECO-FRIENDLY 12,000 BTU PORTABLE AIR CONDITIONER WITH HEATER

WHYNTER ECO-FRIENDLY 12,000 BTU PORTABLE AIR CONDITIONER

WHYNTER ECO-FRIENDLY 12,000 BTU PORTABLE AIR CONDITIONER

EBAC MODEL CD60 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Portable Dehumidifier with Internal Pump

EBAC MODEL BD-150 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Sunleaves Air Conditioner

PORTABLE DEHUMIDIFIER

CAREFULLY READ THESE INSTRUCTIONS BEFORE USING SAFETY PRECAUTIONS USE OF EXTENSION CORDS

ref. com Owner s Manual for models: A Step Above the Standard Thank you for choosing EVEREST

13500 BTU RV Air Conditioner Installation and Operating Instructions

Milk Coolers Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!

EBAC MODEL NEPTUNE INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

π H-6621 INDUSTRIAL DEHUMIDIFIER WARNINGS SPECIFICATIONS uline.com WATER REMOVAL ELECTRICAL REQUIREMENTS BUILT-IN ELECTRICAL SAFETY

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Model 1870F Dehumidifier Installation and Operating Manual

WHYNTER 11,000 BTU DUAL HOSE PORTABLE AIR CONDITIONER

LGR Dehumidifier Owner s Manual

Turbo Air Speed up the Pace of Innovation TBB-4SB CAUTION! PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT

DEHUMIDIFIER. User Manual 50BT, 70BT

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

User Manual. Commercial Refrigerator And Freezer User s Manual

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Ice Cream Freezers

CWR265SZ 26 Bottle Built-in Wine Cooler Owner s Manual

Refrigerator Freezer Installation and Operation Manual

Model 1850F Dehumidifier Installation and Operating Manual

Installation & Operation Manual Ice Cream Freezers

HMT-D30-A HMT-D45E-A HMT-D70E-A. Model Numbers: HMT-D30-A HMT-D45E-A HMT-D70E-A. Portable Dehumidifier Operating Instructions V.

Owner s Manual CMC100 Dehumidifier

RPI Industries, Inc.

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

WHYNTER PORTABLE AIR CONDITIONER

Because you re not like everyone else. EVAPORATIVE COOLER EC220W OWNER S MANUAL

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

Owner s Manual CMC100 Dehumidifier

9,000 BTU Portable Air Conditioner PE1-09R-30. Model No. PE I-O9R Soleus Air International

DEHUMIDIFIERS FDK54 USE AND MAINTENACE MANUAL

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

Whynter Portable Ice Maker 33 lb capacity - White

PORTABLE AIR CONDITIONER OWNER S MANUAL

Table of contents. Installing the charcoal filter 18 Cleaning the prefilter 18 Long term storage 18 Troubleshooting 19 Limited warranty 22

INSTALLATION AND OPERATING MANUAL

Portable Air Conditioner

Refrigerator Freezer Installation and Operation Manual

Portable Dehumidifier

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

95-Pint Dehumidifier with Built-in Pump USER GUIDE IVALDH95PWWP

OWNER S GUIDE READ AND SAVE THESE INSTRUCTIONS

HMT-D30-A HMT-D45E-A HMT-D70E-A. Model Numbers: HMT-D30-A HMT-D45E-A HMT-D70E-A. Portable Dehumidifier Operating Instructions V.

Local Air Conditioner

Up to 60 Pint Commercial Grade DEHUMIDIFIER

PORTABLE AIR CONDITIONER OWNER S MANUAL

USER MANUAL. Portable Air Conditioner and Heater With Heat Pump Technology PAC18. Please read this manual carefully prior to operating the product.

CAREFULLY READ THESE INSTRUCTIONS BEFORE USING SAFETY PRECAUTIONS USE OF EXTENSION CORDS

Model Numbers: HCT-D30-A (TDA30) HCT-D45E-A (TDA45E) HCT-D70E-A (TDA70E) Portable Dehumidifier Operating Instructions V

WHYNTER PORTABLE ICE MAKER 49 LB CAPACITY - STAINLESS STEEL

!3 _!!ili_ '_:_i_;iii_ SG-PAC-12E1 SG-PAC- 12E 1HP. 12,000 BTU Portable Air Conditioner

All about the Use &Care

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCS. Voltage rating: 115V~60Hz Power rating : 1400W

GL-DEH Series Portable Dehumidifier Operating Instructions

RPI Industries, Inc.

Operation and warranty Manual

CD85 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

OWN ER'SGUIDE READ AND SAVE THESE INSTRUCTIONS

Transcription:

Installation and Operations Manual warranty/registrate by scanning ALORAIR Armored 70L AlorAir Solutions INC Add: 16300 Shoemaker Ave,Cerritos,CA90703 Tel: +001-888-990-7469 E-mail: sales@alorair.com

Safety Notes The ALORAIR Series Dehumidifier must always be connected using a grounded electrical connection as required for all electrical appliances. The warranty is voided and all responsibility for the operation transfers to the owner if non-grounded wiring is utilized. The ALORAIR Dehumidifiers must be maintained and serviced by qualified technicians. The ALORAIR Dehumidifiers are intended for use only when the unit is installed in a level and upright position. Operating the unit in any other position could cause water to come in contact with the electrical components. Before moving the dehumidifier, turn off dehumidifier and allow pump to empty reservoir. (Or if unit is already off, press P button to confirm drain reservoir is empty). After the pump has finished operation, unplug the power cord and relocate unit to the desired position. If the inside of the unit has gotten wet for any reason, the unit should be opened and allowed to dry thoroughly before reconnecting to electric and restarting. For proper operation, neither the inlet or discharge should be positioned against a wall. A minimum of 12 clearance between unit and any obstruction is required. Do not insert any objects or fingers into the inlet or discharge. All work on unit should be done with the unit off and unplugged. Do not use water to clean unit exterior. Only use a damp cloth to clean exterior and always unplug the unit first. Do not use unit as shelf or device to hang clothes. This could cause damage to unit. Do not stand on machine.

Table of Contents Features/Specifications Features/Specs... 01 The Armored Series dehumidifier operates based on the refrigerant principle of dehumidification. Identification... 01 High Cop,3.0L/Kwh Eco-Friendly R410A Refrigerant How Your Armored Dehumidifier Works... 02 Unit Overview... 03 Operating instructions... 04 Preparing the Unit for Use... 10 Maintenance... 11 Storing Your Dehumidifier... 12 Troubleshooting... 12 Warranty... 17 Low Sound Levels <52dBA Unit can be ducted, if necessary Pump safety feature overflow protection Automatic (Humidistat) or Manual Control Self-monitoring system Drain Pump with both Automatic and Manual Control If power is interrupted during operation, the unit will automatically restart when power is restored. Identification: For future reference, write down the model, serial number, and date of purchase so you can identify your unit when seeking assistance. NOTE: data label on back of unit includes serial number. Model Number Armored 70L Serial Number Date of Purchase Customer Service: For additional questions concerning the operation of your dehumidifier, please: Contact your installing contractor Email: sales@alorair.com

How Your Armored Dehumidifier Works The ALORAIR Armored Series Dehumidifier utilizes either its integral humidistat to monitor the conditioned space or a manual on/off control to energize the compressor when needed. Air is drawn across an evaporator coil. The evaporator coil is cooler than the dew point of the air so water vapor will turn into liquid condensation. Air is then r eheated through the condenser coil and distributed back into the room. Front View Front cover Unit Overview Handle Installation: WARNING! 120 Volts AC may cause serious injury from electric shock. Air Intake Door Latch 1. Disconnect electrical power before servicing 2. Only plug unit into grounded electrical outlet 3. Do not use extension cord 4. Do not use plug adapter Air iutlet ALORAIR Wheel Power Supply: 220V, 50 Hz AC Only 1 Phase Outlet Requirement: 3-Prong, GFI Circuit Protector: 15 Amp Time Delay Fuse or Circuit Breaker Alternatively, you can manually control unit to operate independent of space conditions. Rear View Place unit in desired location. The inlet of unit should be at least 8 from any obstructions. If unit is transported in the horizontal position, allow it to sit in upright position for at least 30 minutes before operating. WARNING! Hose and Cord Rack Control panel It is recommended that the unit be removed from any location where corrosive or high VOC content materials are applied. Rear cover Air Intake Drain Tube Connection Power Cord Input

Select/OK Menu Operating instructions OK P M Drain Pump On/Off Timer setting:timing for the start/timing Shutdown/Cycle Timing Temperature Scale Switch:Degrees Celsius or Fahrenheit selection Return:Return to display the main page NOTE: See Section 8 for more detailed programming instructions. 4. Select/OK Button OK Use to confirm a selection. up button Down Button LCD Monitor 5. UP Botton Down Botton These buttons are used for adjusting humidity or timer settings. Control Panel Operation 1. ON/Off Button Press this button, and the machine will start running. Press this key again and the machine will stop running. The display will show room humidity levels except while you re pressing another button. NOTE: When unit is turned off, the fan will run for 1 minute prior to shutting off. In addition the condensate pump will pump for approximately 14 seconds to drain the pump reservoir after unit is powered off. 2. Pump Button P For extended storage or movement of the machine, press the Pump bottom to remove water from the integral pump s reservoir. 3. Menu Button M Pressing the Menu (M) button, gives you the options to select between two different control modes as well as adjust the temperature measurement units. Continue pressing the M button until you get to your desired selection. Press the Select (OK) key to confirm that selection and move to a submenu. After you ve completed your task select R thenpress the select (OK) button to moveback to Previous Menu, or wait for 10 S for automatically returning to main screen. Four selections are available: Humidity Setting:Adjust the humidity setpoint 6. LCD monitor When the unit is running, the LCD monitor will go dark if no buttons are pushed. Push any button once to light monitor. 7. LCD display function (1)Show Power On when the machine has already connected but not started. P o w e r o n (2)Show UnitOn when the machine in working status(this display will disappear in 2 seconds and then the next screen will appear.) U n i t O n ( 3) The LCD interface shows two lines of data. The first line displays the room temperature and humidity. On the second line, Job T(working time) and Humidity Setpoint are displayed on an alternating basis. I n l e t 3 2 7 6 % The contents of the second line alternateevery 10 sec.

or J o b. T 0 0 0 5 H u m i. s e t 5 0 % Once the pump reservoir is drained, the contents second linein turn show job hours and total hours alternating every 10 seconds for approximately 1 minute while the fan completes its final cycle. At this point. (4)When you press the Power Offbutton, two lines of data will be displayed. The top line will read Unit Off. The bottom line will read DRAINING for approximately 14 seconds while the pump is emptied. or U n i t O f f D r a i n i n g J o b. T 0 0 0 5 L i f e. H 0 0 8 9 (5) Show Draining when the pump is draining in both automatic and manual modes. I n l e t 3 2 7 6 % D r a i n i n g Time remaining to Auto opening Time remaining to Auto Closing Time remaining tocirculate status 8. Operation and Display ( 1 ) The Humidity Setting (Humid) T i m e O n 0 0 0 5 T i m e O f f 0 0 0 5 I 0 0 1 0 O 0 0 1 0 Note: As long as the machine is plugged into power, the settings can be changed. The unit does not have to be operating to change setup. a. Press the Menu (M) button.the screen shows: H u m i d T i m e r T e m p U R b. Press the M button until Humid is flashing. Press OK to select this option.the screen shows: Show Defrosting when the machine is in defrosting mode.if both Defrosting and Draining are occurring simultaneously, Defrosting is the display priority. H u m i d 3 5 % S e t t i n g R I n l e t 3 2 7 6 % D e f r o s t i n g (6) Second line of display will rotate through several screens depending on setup. Second screen display options: or U n i t O J o b. T 0 0 0 5 L i f e. H 0 f f 0 8 9 d. Press the menu key until the humidity level (bottom left of display) is flashing (it will either say Co for continuous or a number for a specific percentage). e. Use theupor Down buttons to set the machine to your desired level.press the OK Buttonwhen finished.the cursor automatically moves tor which will be flashing.press OK to confirm or wait 10 seconds and you will automatically return to main screen. ( 2 ) Timer Settings (Timer) This selection allows you to set a timer for the unit to turn on or turn off. You can also set up cycle timing, which allows you to set up and repeating cycle of specific on and off durations. a. Press the menu key several times unit the Timer button is flashing. Press OK button to confirm this option.

H u m i d T i m e r T e m p U R b.press the Menu key unit TempU flashes. Press OK to select. c. The screen shows:t.on,t.off,t.i/0,r T. o n T. o f f T. I / 0 R T.on Unit will start when timer expires T.off Unit will stop when timer expires T.I/O Unit will cycle on and off based on the set time. If unit is off, the cycling will start with unit off. If unit is on, the cycling will start with the unit on. d. Press the menu key, move into cursor to function you prefe. 1) Start Time (T.on Selection) a.press to confirm key.the screen runs as follow, the first 00 positions (flashes) at the same time. T i m e r O n 0 0 0 0 O f f R b.press Up and Down key, the first position number from 00-24 variety, choose an hour numberc. Press to confirm key to make selection the number. d.after, the next number position automatically flashes(minute position). Once the correct time is displayed, press to OK key to make selection the number. e.the OFF button will now flash. Press OK one more time, the OFF will switch to ON and the timer is now set. 2) Shut Off Time (T.offSelection). Unit will run for designated time and then turn off. 16 hours. Note: You are selecting on and off periods of time, not set clock times. a. Press the M button until the T.I/O selection is flashing. Press OK button to select. b. Use the up and down arrows to adjust the hours and minute of the first cycle. c. Use the M button to move from 1st line of display to second and adjust second time period with up and down buttons. d. Press the OK button to confirm the time. (Flashing OFF will turn to ON). ( 3 ) Temperature scale set This selection allows you to switch the machine from displaying temperature in degrees Celsius to degrees Fahrenheit. a. Press the menu key.the screen shows:humid,timer,tempu, R. H u m i d T i m e r T e m p U R b.press the Menu key unit TempU flashes. Press OK to select. c. The screen shows:celsius degree on/off and Fahrenheit degree the off/on. T e m p U S e t t i n g O n o F O f f R d. Press the menu key to move the cursor to the on/offor off/on(flashes). e. Press to confirm key. The on/off status of C and F will exchange. 9.Optional Duct Installation This Ducting opintion is allowed you to give the special dry to the particular wet location and make it fixed in repadly,diameter for this ducting is 160mm,Layflat ducting can be used for this choice. a. Press the M button until the T.off button is flashing. Press OK to confirm. b. Set timer as above. 3) Cycling Timer (T.I/O Selection) The third selection, T.I/O, lets you set up the machine to cycle on and off during a specific time frame. For example, you could set the unit to run 8 hours a day and remain off the other

the unit features an integral drain pump, drain line may go vertically up 18 prior to reaching final drain location. Discharge Ducting 10.Handlebar Mounting Handle rotates 180, after aligning with locating pin holes will be fixed. Quick connection to draining tube The quick connector into the socket on the connector ALORAIR The locating pin is inserted and fixed Preparing the Unit for Use ( 1 ) Position the machine for a minimum 8 clearance on back and sides. Front should be positioned for maximum discharge distance or directly to specific location for spot drying. If the unit was moved in such a manner that the compressor didn t remain in a vertical orientation, wait a minimum of 30 minutes before turning the unit on. ( 3 ) Firmly insert power cord into socket on top back of unit. ( 4 ) Set unit control as desired and energize. Maintenance and Repair 1. Exterior Cleaning Use a soft, slightly damp cloth to wipe the plastic body. ( 2 ) The included drain line attaches to the unit via a quick connection type fitting located on the base of the unit.the drain line should be routed to a suitable drain or outside. Because 2. Filter cleaning a. Remove the inlet grille to access the filter

1. Electronic Control Maintenance a. To release screws on the rear cover removed Release these 4 Screws ALORAIR Press and hold the button pressed down the door opened and pulled out of the filter Release these 2 Screws b. Filter may be cleaned by vacuuming or by washing with warm water (no soap or solvents). Insure filter is dry prior to restarting unit. b. Open the cover and remove the Electrical box cove c. Reinstall Filter into Unit Release these 2 Screws 2. Water Pump Maintenance ALORAIR The filter insert the filter box then close the wind panel ALORAIR The pump is designed with quick connection construction. condensate tube, float switch connections, and the main power cord to pump can easily be disconnected. The pump can be removed from reservoir by using a flat screwdriver to gently pry pump assembly from reservoir. If service is required, Maintenance WARNING ALWAYS UNPLUG UNIT PRIOR TO PERFORMING ANY MAITENANCE Your ALORAIR Armored is equipped with an integral condensate pump designed to pump condensate from your dehumidifier out to the desired drain. This pump requires routine maintenance that is not covered by your Pump Open the rear cover and pull the pump out

1 year parts warranty. Only a defective pump will be repaired or replaced during the warranty period. Preventative Maintenance As with all pumps, preventative maintenance is necessary to prevent issues from dirt and slime that may accumulate in the drain system including the drain pan, hose to the condensate pump, pump reservoir, pump head and float assembly, and discharge tubing. At least once per year, clean pump system Storing Your Dehumidifier If the unit will be stored for an extended period of time: 1. Turn unit off and allow to dry. 4. Clean the filter mesh. 2. Manually drain pump reservoir. 5. Store in clean,dry environment. 3. Wrap and secure the power cord. Coil- If necessary, clean your coils with a vacuum or approved coil cleaner. Basic- 1. Press the pump button (P) to drain water from reservoir. 2. Disconnect power to dehumidifier. 3. Mix a 16 oz solution of either 1 oz bleach to 15 oz water or 4 oz white vinegar to 12 oz water.pour into the drain tray at the base of the coils. Note: If you get any cleaning solution on the coils, flush with water. 4. Allow to soak for 15 minutes. 5. Reconnect power to dehumidifier. 6. Fill reservoir and flush/cycle pump at least two times. 7. Repeat if needed or refer to Advanced instructions. Advanced- 1. a. Use manual pump button P, to drain water from reservoir. b. Unplug the dehumidifier and open cover to access pump. c. Pump head can be removed from reservoir by pressing on tabs. d. A wet-dry vacuum or towels can be used to remove remaining water from reservoir. 2. Fill pump reservoir with a diluted cleaning solution (15 oz water to 1 oz bleach or 12 oz water to 4 oz white vinegar). 3. Reassemble pump and use manual pump button to flush mixture through discharge tubing. 4.Pour same diluted mixture slowly into drain pan under evaporator coil and allow it to clean hose from pan to pump. This process can be stopped when the pump energizes 1 time. Note: If you get any bleach/water mixture on coils, flush with water. 5. Pour sufficient clean water through drain pan to force pump to activate twice. 6. Reassemble unit and return it to operational status. Trouble Machine Won t Work/ Display is Blank Cannot start the dehumidifier No Airflow Loud/Unusual Noise Trouble code:e1 Trouble code: E4 Troubleshooting cause Display Blank. Power outage or poor connection Room temperature outside unit operating range. HI or LO Error Filter mesh is clogged Air inlet or outlet jammed Filter mesh jammed Unit is not level Pump dislodged Humidity Sensor or communication error Pump detected high water in reservoir (See Notes Below) Clean the filter Clean the filter Solution Check Power Supply Check both ends of power cord for good connection Modify room conditions in between 33 F and 100 F. Clear the blockage from air inlet or air outlet Place unit on flat surface in vertical orientation Reassemble pump as necessary Check sensor cable is properly connected.replace the Senser Check for clogged drain lines Check pump working properly Service Pump Replace Pump

Trouble code: L0 Trouble code: HI Trouble code:e1,l0,hi Pump Alarm-Error Code E4 If a pump alarm is provided on display: 1. Clear error code by disconnecting power cord and then reconnecting. NOTE: Unit will not function until error code has been cleared. 2. Manually check to see if pump is operational. Press pump button (P) and see if pump energizes and de-energizes properly and if any water is purged from system. If you haven t cleaned the system recently, check discharge line for obstruction and clean balance of pump system per instruction above. Unit is sensing room temperature below 33 F. Unit is sensing room temperature above 100 F. Shows E1, L0,HI at the same time indicated a bad connection, cable or sensor 3. Replace hoses and or pump if maintenance alone is not sufficient. Increase room temperature Check Sensor Check Sensor Cable Decrease Room Temp Check Sensor Check Sensor Cable Check Cable connection Replace Cable Replace Sensor Warranty Seller warrants the equipment to be free from defects in workmanship and materials for a period of 12 months after shipment (60 months/5 years on compressor, evaporator and condenser). This warranty is limited, however, to the repair or replacement of defective equipment. If it is necessary to return unit for service, customer is solely responsible for proper packaging, transportation costs. Customer must initiate warranty process by contacting factory. Do not send any component or product back to factory without Return Material Authorization. This limited warranty does not apply to any part or component that is damaged in transit or when handling, has been subject to misuse, corr osion, chemicals, acts of God has not been installed, operated or serviced according to the Seller s instructions, or has been operated beyond the factory-rated capacity or has been altered in any way. Routine maintenance is not covered by this warranty. Seller s liability is limited to replacement of defective parts or components and does not include any cost of labor (including, but not limited to, labor to remove and/or reinstall any defective part), refrigerant or piping. Customer may elect to have unit fixed locally in which case required replacement parts will be sent to customer at customer s expense. ALORAIR shall not be responsible for loss of use of any product, loss of time, inconvenience, or damage to other equipment, or any other indirect or consequential damage with respect to property whether as a result of breach of warranty, neglect, or otherwise. THE WARRANTIES AND LIABILITIES SET FORTH ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED, IN LAW OR IN FACT, INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE. ALORAIR s total liability, regardless of nature of claim shall not exceed original purchase price of the product. If a product or component is replaced while under warranty, the applicable warranty period shall not be extended beyond the original warranty time period. The foregoing shall constitute the total liability of seller in the case of defective performanceof all or any of the equipment or services provided to Buyer. Buyer agrees to accept and hereby accepts the foregoing as the sole and exclusive remedy for any breach or alleged breach of warranty by Seller.

AlorAir Warranty Steps: 1. Once receive the goods, customers must log in www.alorair.com to fill out the warranty registration form and submit to AlorAir company. We will receive your purchasing and installation information and save it. If no warranty registration is sent to us, warranty period will begin the day the shipment left the warehouse. Please be sure to record serial # and date of installation. You will need this information to receive the RA number. 2. If warranty service is necessary, customers must contact Alorair Tech Support by sales@alorair.com or local technical service phone to receive a Return Authorization (RA number). Once an RA has been issued, customers should bring the unit to a certified repair center. AlorAir will arrange the shipping to bring the unit back to the Alorair warehouse (at the expense of the customers) if customers are not available. 3. After the unit has been received by Alorair (whether at a repair center or the warehouse), Alorair will have an initial inspection. If it is determined to be invalid warranty claim (see exclusions below), customers have to pay for all associated repair costs and shipping costs for units repair. 4. Customers can pick up the unit after repair at their own expense for shipping. Units will have a rigorous testing before sending it back to customers 5. If the unit can no longer be fixed, and it is in the warranty period and determined to be valid claim, we will ship the customer a new unit within the same year warranty from the date of replacement. 6. After parts are repaired or replaced by AlorAir, the original warranty period continues to applies until meet its deadline.