Catalogue Telecommunication Cables INTRODUCCIÓN

Similar documents
Telecommunication Cables

Catalogue Power Cables

Catalogue. Instrumentation & Control Cables

Power Cables. Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7. ELECWIRES 2 Page

Shipboard & Offshore Cables

Flame Retardant Overall Screened Instrumentation Cables (multicore)

Multi-Core Fire Resistant Cable

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores)

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

PRODUCT CATALOGUE Norröna

FIRE RESISTANT CABLES

OIL & GAS INDUSTRY OTHER INDUSTRIES

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

Caledonian Flame Retardant Coaxial Cables

High Performance LSZH Fire Resistant Cable

SAS Security and Alarm Safety Cables

Havells Fire Survival Cables

Compact Module. Category 6A FTP Cabling System 1.1

Core identification code. J-YY...BD Indoor Cable. J-YY...BD Indoor Cable. VDE 0815 Mutual capacitance. J-YY...BD Indoor Cable. Cu conductor 0.

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)

THE INNOVATIVE CABLE PRODUCER INSTRUMENTATION CABLES FOR THE INDUSTRY - AND PLANT CONSTRUCTION

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore)

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.

Tratos Railway Cables

Caledonian Fire resistant Coaxial Cables

BS /1000V XLPE Insulation LSZH Sheath Cables

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

FIRE PERFORMANCE CABLE

ENHANCED FIRE PERFORMANCE CABLE

SPECIAL ELECTRICAL AND OPTICAL CABLES

Caledonian fire Resistant signal & Data cables

Method of test defined in IEC for determining the circuit integrity performance of a cable under fire conditions.

fire resistant cables

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

Table of Contents. TELE-FONIKA KABLE SA (DMCC Branch). 4 TELE-FONIKA Kable Group 6 FLAME-X 950 SERIES 1 11 FLAME-X 950 SERIES 2

Cable technology for highest safety requirements

The Quality Connection. BETAflam Fire Resistant Safety Cables

Sensor and transducer cables

BS EN : Measurements Of Smoke Density Of Electric Cables. WF Report Number. Date: 17 th November Test Sponsor:

Fibre Optic Cable. Catalogue.

Total Fire Solutions. Includes BS 8519 and the updated BS :

BS 6387: 1994 Specification for performance requirements for cables required to maintain circuit integrity under fire conditions.

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

INTRODUCTION. Our diverse range of world-class Specialty Insulated Wires and Cablesinclude: LV Cables -

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES

STANDARDS INSTALLATION. Certificate No 077m

Introduction.

Firecel Safety Cables

BS FP600 achieves the maximum 120 minute rating under the BS test conditions, which is required for fire fighting applications.

Caledonian. FIREFLIX ire Resistant Coaxial Cables

Lloyd s Register Type Approval System Test Specification Number 3

CLEARING MISCONCEPTIONS ABOUT LOW-SMOKE, HALOGEN-FREE CABLES

Product Specification CAT 6 UNSHIELDED PATCH CORDS

INTERNATIONAL STANDARD

Flexflame. Arctic Grade Cables for Extreme Conditions. Photo: Sakhalin Energy Investement Company Ltd.

Specification Document. Color-changing Recovery Type Water Leakage Sensor AD-RS

THE MYSORE UNIT OF RPG CABLES MANUFACTURES A RANGE OF INSTRUMENTATION CABLES

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

INTERNATIONAL STANDARD

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION

DNVGL-CP-0402 Edition February 2016

FIRE RESISTANT CABLES FP200 GOLD

(Notices) EUROPEAN COMMISSION

MEDIUM VOLTAGE CABLES INSTRUMENTATION CABLES RUBBER CABLES FIRE RESISTANT CABLES

CABLES FOR ALARM AND SAFETY SYSTEMS

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2017/C 298/02)

IEC Method of test defined in IEC / -21 for determining the circuit integrity of electric cables under fire conditions

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

DNVGL-CP-0401 Edition February 2016

CATEGORY 6A FTP RJ45 SOLUTION

THE TRUE FIRE SURVIVAL CABLE

Power Control Cable Iec

Flexible Power Cable DLO

GAS FLOODING SYSTEM FOR CIFF AT BASEMENT

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)

Low Smoke Zero Halogen

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

Author Owner Issue Authority Name: Gordon MacKenzie Title: Senior Engineer Engineering Design and Standards

CORRIGENDA. (Publication of titles and references of harmonised standards under Union harmonisation legislation)

Easy to install in ducts, tunnels and trenches by means of compressed air or pulling wire. Suitable for direct burial (crush 400 N/cm).

FIRE RESISTANT CABLES FP PLUS. New Generation. Now with enhanced Insudite TM insulation

Specification Document. Heat-resisting Type Water Leakage Sensor FR-AD

Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

Comtran Cable. Hub-LINK Cables for Transit Applications

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Test Report No: ICL/H17/7967

Traction Cable Radox 3 GKW

Duct Cable GYTS-144B1.3

Photovoltaic Cables EN H1Z2Z2-K

TYPE APPROVAL CERTIFICATE

Overmoulded Cable Assembly Selector Guide

Single core cables with reduced wall thickness

Fire Resistant Cables

CONTENTS. Introduction Customer Service BS codes of practice BS Fire Performance Cable Selection Guide... 7

DNVGL-CP-0399 Edition March 2016

The Quality Connection. BETAflam safety cables for highest demands

13. UNITED KINGDOM Standards Supply Voltage and Plug Configurations 247

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

Transcription:

Catalogue Telecommunication Cables INTRODUCCIÓN Conductores Tecnológicos S.A. www.contecsa.es

Index of Cables Page Introduction 3 EAP / EAP-R 4 EAPSP / EAPSP-R 5 ISP / ICP 6 Conductores Tecnológicos S.A. 2 www.contecsa.es

INTRODUCTION Telecommunication Cables Telephone cables suitable for low & medium frequency signal transmission, voice and data. Some of the most extended applications is user loop and switch interconnections. The cable design can be made for indoor and outdoor uses. Cables may be screened to reduce interferences between pairs and/or other undesired signals. The most common configurations can be manufactured either in pairs or quads and are: Outdoor Use (PE black), switchboard connection: EAP / EAP-R*. Screened Cables EAPSP / EAPSP-R*. Screened and Armoured Cables Indoor Use (PVC grey), building intercommunication: ISP. Unscreened Cables ICP. Screened Cables Option R*. Liquid-repellent materials can be used to prevent liquid and undesired substances from filling the gaps inside the installed cable. According to cable behaviour against fire, the above mentioned configurations can be manufactured: Fire resistant. IEC 60331, UNE-EN 50200 & UNE-EN 50362 Fire retardant. IEC 60332-3 Cat. C & UNE-EN 50266 Cat. C Flame retardant. IEC 60332-1 (UNE-EN 60332-1-1) & IEC 60332-2 (UNE-EN 60332-1-2) Low Smoke Emission. IEC 61034 (UNE-EN 61034) Halogen free. IEC 60754 (UNE-EN 50267) OPTIONS & ALTERNATIVES Different types of cable features can be provided: Hydrocarbon and mineral oil resistant. UNE-EN 60811-2-1 & UIC 895 OR Configurations with different types of armours and materials Conductores Tecnológicos S.A. 3 www.contecsa.es

TELECOMMUNICATION CABLES EAP / EAP-R* pairs or quads Construction: Conductors Annealed electrolytic copper. Class: 1 Nominal diameter: from 0.4 to 1.3 mm. *OPTION, composition acc. to AWG (American Wire Gauge). Insulation HDPE (High Density Polyethylene). Assembly Pairs, triads or quads. Groups are cabled in concentric layers to build the cable core. Humidity Protection* Separator *OPTION R, addition of liquid repellent filler to seal the cable core. Polyester tape. Overall Screen Copolymer-aluminium- copolymer. Outer Sheath *OPTION, LSZH thermoplastic (Low Smoke Zero Halogen) fire-flame resistant. Application & Properties:: Cable suitable for outdoor telecommunication services under conditions which require electromagnetic protection as well as weather proof properties (sealed cable core). Standards: These cables are manufactured under the specifications of the main telecom companies. Upon request any configuration can be provided. *OPTIONS (others available under request) Humidity Protection Liquid repellent filler Sheaths LSZH Fire-flame resistant Conductores Tecnológicos S.A. 4 www.contecsa.es

TELECOMMUNICATION CABLES EAPSP / EAPSP-R* pairs or quads Construction: Conductors Annealed electrolytic copper. Class: 1 Nominal diameter: from 0.4 to 1.3 mm. *OPTION, composition acc. to AWG (American Wire Gauge). Insulation HDPE (High Density Polyethylene). Assembly Pairs, triads or quads. Groups are cabled in concentric layers to build the cable core. Humidity Protection* Separator *OPTION R, addition of liquid repellent filler to seal the cable core. Polyester tape. Overall Screen Copolymer-aluminium- copolymer. Inner Sheath Armour Steel corrugated tape. Outer Sheath *OPTION, LSZH thermoplastic (Low Smoke Zero Halogen) fire-flame resistant. Application & Properties:: Cable suitable for outdoor telecommunication services under conditions which require electromagnetic protection as well as weather proof properties (sealed cable core). The armour provides very high mechanical and anti rodent protection. Standards: These cables are manufactured under the specifications of the main telecom companies. Upon request any configuration can be provided. *OPTIONS (others available under request) Humidity Protection Liquid repellent filler Sheaths LSZH Fire-flame resistant Conductores Tecnológicos S.A. 5 www.contecsa.es

TELECOMMUNICATION CABLES ISP / ICP* pairs or quads Construction: Conductors Annealed electrolytic copper. Class: 1 Nominal diameter: from 0.4 to 1.3 mm. *OPTION, composition acc. to AWG (American Wire Gauge). Insulation HDPE (High Density Polyethylene). Assembly Pairs, triads or quads. Groups are cabled in concentric layers to build the cable core. Separator Polyester tape. Screen* *OPTION ICP, Aluminium-polyester tape. Outer Sheath *OPTION, LSZH thermoplastic (Low Smoke Zero Halogen) fireflame resistant. Application & Properties:: Cable recommended for indoor telecommunication services because of excellent performance against fire. Standards: These cables are manufactured under the specifications of the main telecom companies. Upon request any configuration can be provided Fire retardant IEC 60332-3 (C) UNE-EN 50266-2-4(C) Flame retardant IEC 60332 UNE-EN 60332-1 *OPTIONS (others available under request) Sheaths LSZH Fire-flame resistant Conductores Tecnológicos S.A. 6 www.contecsa.es

Rev. 0 (01/12/2009) If you want to know more about us, please visit www.contecsa.es Conductores Tecnológicos S.A. 7 www.contecsa.es