Section H11 BLOWDOWN SEPARATORS CONTENTS FEATURES AND BENEFITS...H11-3 PRODUCT OFFERING...H11-3 SAMPLE SPECIFICATIONS...H11-11 ILLUSTRATIONS

Similar documents
Blowdown Separator & Aftercoolers Installation, Operation, & Maintenance

Blowdown Separator & Aftercoolers

Centrifugal Blowdown Separators and Tanks

Series 1140 and 1141 Temperature Regulators

Aldrich Blowdown Separators & Cooling Manifolds

BuildingName The Description of the Project P DOCUMENTS

THERMOSTATIC STEAM TRAPS

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

Design and Construction Standards SECTION PLUMBING EQUIPMENT

SECTION PLUMBING EQUIPMENT

FUEL-FIRED VERTICAL TUBELESS BOILERS

WHY THE REMOVAL OF NONCONDENSABLE GASES AND AIR IS CRITICAL IN A STEAM SYSTEM

PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS

Condensate Pumps Jones Boulevard Limerick Airport Business Center Pottstown PA Tel:

SECTION PLUMBING EQUIPMENT

High Capacity Instantaneous Steam Fired Water Heater

HYDRONIC SPECIALTIES TACO AC(F)-PAX 05/15/2008

TECHNICAL. Series 18. Pump Packages

USG Series. Unfired Steam Generators Generate Clean Steam With Boiler Steam or High Temperature Hot Water as the Energy Source

HYDRONIC SPECIALTIES TACO AC(F)-CA 05/08/2008

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL

Series 151 and AV5. A wide range of process thermostatic steam traps is available to match almost any application need.

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

Intelligent Refrigeration Solutions

Packaged Semi-Instantaneous Steam Fired Water Heater

HORIZONTAL FIRE TUBE BOILERS Piping (HVAC) Pumping Equipment (HVAC).

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

THERMODYNAMIC STEAM TRAPS

SECTION METERS AND GAGES FOR HVAC PIPING

Refrigerant Valves/Accessories

Packaged Instantaneous Domestic Hot Water Generator Energy Source: Boiler Water

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

Silhouette. Feedwater Heater. Boiler Feedwater

Packaged Steam Fired Water Heater

PT15 MATERIAL : DIMENSIONS - Nominal in inches. AVAILABLE SPARES: Disc (Packet of 5) ORDERING INFORMATION: Refer to "HOW TO ORDER" page.

LIQUIDATOR UMT-TD Series Thermodynamic

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

THE THERMOSTATIC STEAM TRAP

YARWAY PROCESS THERMOSTATIC STEAM TRAPS SERIES 151 AND AV5

AFUE 95% Heating Input 50,000 to 200,000 Btuh

Armstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual

Stainless Steel Condensate Return Units

Instant hot water Feed-Forward system unlimited supply accurate to +/- 4 F

Fuel-Fired Vertical Tubeless Boilers

TABLE OF CONTENTS STEAM TRAPS INVERTED BUCKET SERIES PAGE FLOAT AND THERMOSTATIC SERIES PAGE THERMOSTATIC THERMODISC B0 26. How to Select All 107

.2 Section Waste Management and Disposal..5 Section Performance Verification of Mechanical Piping Systems.

In-Line Air Separators

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

EZ Plate Instantaneous

YARWAY PROCESS THERMODYNAMIC STEAM TRAPS SERIES 40/40D AND C250/260

THERMODYNAMIC STEAM TRAPS

SAMPLE SPECIFICATIONS

Hoffman Specialty General Catalog

STEAM TRAPS

SECTION METERS AND GAGES FOR PLUMBING PIPING

NICHOLSON STEAM TRAP THERMODYNAMIC STEAM TRAPS

University of Delaware

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

Removal of Non-condensable Gases and Air Is Critical In A Steam System

BASCO TYPE T and TC MOISTURE SEPARATORS and TRAP. ...world leaders in heat transfer technology

FT600 & FT601* Steam Traps Float & Thermostatic Steam Trap. Float & Thermostatic STEAM TRAPS

SECTION HEATING BOILERS

Boiler Condensate Return Basics. Presented by Steve Connor February 24, 2016

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

SALES TRAINING HEAT RECOVERY SYSTEMS BLOWDOWN SEPARATORS & TANKS LIQUID SAMPLE COOLERS ORIFICE METERS

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

Peerless Pump Company

BOILER HOUSE PRODUCTS GMS

MOHICAN. MOHICAN 4-Pass Water Boiler, HP, PSI Section

Water Piping and Pumps

Commercial Semi-Instantaneous Water Heaters

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

/ / Take the technological step into MODERN Condensate Handling Equipment for steam systems MANUFACTURED IN AMERICA with craftsmanship and quality.

LIQUIDATOR 450 SERIES

SB Series Brazed Plate Heat Exchanger Installation Manual

UNFIRED STEAM GENERATORS STANDARD EQUIPMENT

Our Know-How. Your Peace of Mind. Steam Solutions

PIONEERS IN AIR VACUUMS

RHP120 RHP300 Steam Boiler Series

EHB Series. STONESTEEL Commercial Electric Water Heaters Individually Mounted Elements Vertical or Horizontal CEMLINE CORPORATION

Installation, Operation and Maintenance LOK-FLANGE Multitube Heat Exchangers

OPERATING AND MAINTENANCE MANUAL FOR BOILER WATER OR HIGH TEMPERATURE HOT WATER (HTHW) POWERED WATER HEATER

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-214(C) Series 61 Low Water Cut-Off OPERATION

Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series

Hard-hitting Contenders In HVAC Fluid Handling Solutions

Water Fuel + Air for combustion Blowdown

HYDRONIC SPECIALTIES TACO MPT Tank(s) 05/30/2012. A. Multi-Purpose Tank buffer tank, air separator, and hydraulic decoupler

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES

Domestic Pump Condensate Transfer Equipment

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

SERVICE MANUAL. For Service & Parts please call APK THERMAL at or SAFETY INSTRUCTION

Owner's Manual. (200 Gallon Lawn Service Skid Sprayer) Technical Specifications. Operation. General Information. Warranty/Parts/Service

D-8 OUTLINE SPECIFICATION FOR HTHW HEAT EXCHANGERS

SECTION STEAM CONDENSATE PUMPS

"ER" Series Electric Humidifier

CD-33/CD-33S Controlled Disc Steam Traps

Hydrocarbon & Chemical Processing Solutions

SH-2000, SH-2500, AB-3000 Bimetallic Steam Traps Installation and Operation Manual SH-2000

Steam and Condensate Technology. Solutions which are brilliant in their simplicity. combined with a first-class design & consultancy service.

Mini Pump Trap. Features: n Low maintenance - No leaking seals, impeller or motor problems reducing maintenance and downtime.

Transcription:

Section H BLOWDOWN SEPARATORS CONTENTS FEATURES AND BENEFITS...................................................H- PRODUCT OFFERING.......................................................H- SAMPLE SPECIFICATIONS...................................................H- ILLUSTRATIONS Figure H-. Blowdown Separator Dimensions....................................H- Figure H-. Automatic Drain Water Aftercooler (DF) Dimensions.....................H-7 Figure H-. Automatic Drain Water Aftercooler (0AO) Dimensions.....................H-7 Figure H-. Model D Dimensions............................................H- Figure H-. Separator Floor Stand............................................H-9 Figure H-. Separator Wall Bracket...........................................H-0 TABLES Table H-. Boiler Blowdown Separator Sizing....................................H- Table H-. Cooling Water Line and Valve Sizing...................................H- This section contains information on blowdown separators, which are used to provide safe and economical flash purification to enhance blowdown effectiveness. H-

Blowdown Separators Section H Notes H-

Section H Blowdown Separators FEATURES AND BENEFITS PRODUCT OFFERING Fast, Safe, Low-Cost Way to Separate Steam and Water and Remove Harmful Dissolved Solids. Protects boiler surfaces from severe scaling or corrosion problems. Economical Flash Purification Process for Enhancing Blowdown Effectiveness. Reduce drain water temperature to meet state and local requirements. The Design is Quiet, with Noise Levels Held Below 90 dba, so no Exhaust Head is Required. CB Blowdown Separators are Compact, and Can Be Quickly Installed with Few Connections. Stainless steel striking plate greatly extends separator life. Momentum of Water is Speeded by Spiral Baffle Centerwise to Drain. Drain is Completely Filled - No Center Void. Tangential inlet and small diameter prompt high velocity spinning for release of steam. All Interior Surfaces Slant Toward Drain, Making Unit Self- Draining, Self-Drying for Longer Life. Proven Performance. Demonstrated Durability. Universal Adaptability. Boilers that supply steam for power, process or heating applications require periodic and more often, frequent, blowdowns to prevent buildup of harmful solids. Blowdown protects boiler surfaces from severe scaling or corrosion problems that would otherwise result. Cleaver-Brooks blowdown separators use a safe, economical flash purification process for enhancing blowdown effectiveness. Steam is rapidly separated from blowdown water and vented out the top of the blowdown separator in a cyclonic spinning action. Water and dissolved solids are flushed out the bottom drain. The design is quiet, with noise levels held below 90 dba, so no exhaust head is required. Internal pressures do not exceed psig. Blowdown water is cooled to 0 F by a drain tempering device, designed to meet state and local codes. Cleaver-Brooks blowdown separators are compact, and can be quickly installed with few connections. Accessories include leg or wall brackets, drain tempering fitting, strainer, temperature regulating valve, thermometer, pressure gauge and flanges. Pressure ranges: 0 to 00 psig, standard. 0 to 00 psig, special. Available with ASME U stamp. H-

Blowdown Separators Section H Inspection Port "V" Vent "A" +/- /" SS Wear Plate 9" "H" +/- /" "I" Inlet "PL" MODEL NO. A0B AB AB H Dimension A Dimension 0 0-/ I Inlet size Determined by blowdown valve size. :V Vent size Select from Table H-. D Drain size Select from Table H-. PL Plate size / or /. May be determined by codes. " Section A-A Model No. MAWP 0 PSIG at 0 F A "D" Drain HEADS SA -70 SHELL SA B COUPLINGS SA 0 WEAR PLATE SA 0-0 BAFFLES SA 0-0 NOZZLES SA B, SA 0-B FINISH RED OXIDE PRIMER Figure H-. Blowdown Separator Dimensions Table H-. Boiler Blowdown Separator Sizing VALVE SIZE " " -/" " -/" Separator Dim. Model H I D V Model H I D V Model H I D V Model H I D V Model H I D V Generator Op psig 0- -0-00 0- -0-7 7-00 0- -00 0 0 -/ -/ -/ 0 0 0 -/ -/ -/ -/ -/ -/ -/ -/ -/ 0 -/ -/ -/ -/ -/ -/ -/ -/ -/ -00 psig U. Symbol Construction and Stamping is required. To use this chart:.select separator size from this table by matching operating pressure and blow-down valve size..select Plate Thickness (PL) as local regulations require or as desired for maximum pressure stamped on Separator /", 0 psig, /", psig, /", 0 psig..if local regulations require, indicate ASME or Standard. Separator size is now determined and discharge piping may follow these sizes with no calculation necessary. Separators are designed to exhaust at less than psig. H-

Section H Blowdown Separators Standard and Optional Equipment Selection For dimensions and sizing of blowdown separators, refer to Figure H- and Table H- For manual drain water tempering, use Aftercooler model D and specify drain diameter. For automatic control of drain water temperature, use DF or 0AO Aftercooler. 0AO Aftercooler is required in some areas to automatically regulate the temperature of the water to the drain. Check local codes to ascertain if it is required in your area. A temperature regulating valve should be used when the blowdown temperature going to the drain needs to be less than F. (See Table H- to select cooling water line and valve size.) Use a solenoid valve and thermostat when the cooling water pressure exceeds 0 psig.. Model DF Aftercooler (Figure H-). Nonclogging automatic drain tempering fitting with stainless steel mixing tongue (on " and larger) to provide thorough mixing of influent cold water with drain water. The middle flange permits rotation for various pipe fitting requirements and also serves as a dismantling flange. Two bulbwells for mounting control valve and thermometer are furnished. When ordering, state cold water inlet size.. Model 0AO Jacket Type After Cooler (Figure H-). Required in some areas. Has mixing holes corresponding to the cold water inlet size. The lower portion is designed with wells to accommodate automatic control bulb and thermometer. When ordering state cold water inlet size.. Temperature Regulator Valves Figure H- and Figure H-). Automatically control the flow of cold water by responding to temperature changes at the thermostatic bulb. The " capillary tube allows installation in the cold water line while the " bulb is mounted in the lower portion of the aftercooler. The valve size should correspond to the cold water inlet.. Thermometer. Bi-metal, drawn steel case, rust resistant and finished in oven baked enamel. Six inch brass stem with /" NPT bushing provided for use with Model DF and Model 0 AO Aftercoolers.. Solenoid Valve. Automatically controls cooling water to aftercooler. Non-magnetic stainless steel body; micro-finished, hardened pilot valve ball. Has two-wire control circuit (0/0). Well immersion hot water control provided for actuating solenoid valve.. The Model D Drain Tempering Fitting (Figure H-). Simple type of aftercooler for adding cooling water with manual control. It has cold water inlet for adding cooling water to drain for tempering to 0 F. Inlet is sized for minimum influent water conditions of 0 F water at 0 psig pressure with 00 sq-ft of supply. When ordering, state Model D (Drain Diameter); i.e. for " drain use Model D. 7. Armstrong Strainer. Cast iron with.0 stainless steel screen. Install in cold water line to protect temperature regulator valve or solenoid valve shown in adjacent column.. Separator Floor Stand (Figure H-). Provides and excellent means for supporting separators. Constructed of sturdy angle iron. They come attached to the H-

Blowdown Separators Section H separator to provide an easy and expedient means of installation. Standard height raises separator inches from floor, or when aftercoolers are provided, additional height is provided. 9.Separator Wall Brackets (Figure H-). For wall mounting where floor space is limited, or where desired installation is at a level higher than leg height of inches. H-

Section H Blowdown Separators A B C CWI C -/ 0 0 0 0 0 0 0 0 0 0 0 -/ -/ -/ -/ -/ -/ / / / / -/ -/ NOTES:. Temperature regulator valve bulb is installed in lower section of the aftercooler so that the bulb senses mixed water temperature. Valve is modulating so that the right amount of cold water is added to cool the drain water to the desired temperature set on the valve. Valve range is to 0 F.. Regulator Valve has composition seat to ensure tight shut-off when not blowing down. Valve should be protected with C.. Strainer with.0 mesh. B C CWI - COLD WATER INLET - NPTF STAINLESS STEEL MIXING TONGUE SUPPLIED ON MODELS DF AND LARGER / NPTF CONNECTION TO ACCOMODATE BIMETALLIC THERMOMETER /, /, OR NPTF CONNECTION TO ACOMODATE REGULATOR VALVE SENSING BULB. CWI = cold water inlet size. A Figure H-. Automatic Drain Water Aftercooler (DF) Dimensions D D CWI -/ / / / / -/ -/ NOTES:. Temperature regulator valve bulb is installed in lower section of the aftercooler so that the bulb senses mixed water temperature. Valve is modulating so that the right amount of cold water is added to cool the drain water to the desired temperature set on the valve. Valve range is to 0 F. CWI COLD WATER INLET NPTF / NPTF CONNECTION TO ACCOMODATE BIMETALLIC THERMOMETER /, /, OR NPTF CONNECTION TO ACOMODATE REGULATOR VALVE SENSING BULB D D -/ D 0. Regulator Valve has composition seat to ensure tight shut-off when not blowing down. Valve should be protected with C.. Strainer with.0 mesh.. CWI = cold water inlet size. Figure H-. Automatic Drain Water Aftercooler (0AO) Dimensions H-7

Blowdown Separators Section H Table H-. Cooling Water Line and Valve Sizing SEPARATOR INLET SIZE COOLING WATER PRESS. (PSIG) " -/ " -/" 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 GENERATOR OPERATING PRESSURE (0 TO 70 F COOLING WATER TEMPERATURE) 0-0 -00 0- -7 7- -0-00 / / / / / / / -/ -/ -/ -/ -/ -/ -/ -/ -/ -/ -/ -/ -/ -/ -/ -/ -/ -/ -/ -/ -/ GENERATOR OPERATING PRESSURE (7 TO 0 F COOLING WATER TEMPERATURE) 0-0 -00 0- -7 7- -0-00 / / / / / / -/ -/ -/ -/ -/ -/ -/ -/ -/ -/ -/ -/ -/ -/ -/ -/ -/ -/ -/ -/ -/ -/ -/ -/ -/ -/ -/ Use the chart as follows:. Depending upon the temperature of the cooling water used, locate the section of the chart which applies, 0-70 F or 7-0 F.. At the top of chart locate Separator inlet size and in left column under the section selected in step one, locate Boiler Operating pressure. You now have a selection of three valve sizes.. From the top of chart select the cooling water line pressure either 0, 0 or 0 and read the desired valve and line size. A B C CWl / -/ / 7 -/ 7 -/ COLD WATER INLET - NPTF 7 -/ -/ Furnish and install a manual drain water aftercooler Model D and with a cold water connection. NOTE:. Temperature regulator valve bulb is installed in lower section of the aftercooler so that the bulb senses mixed water temperature. Valve is modulating so that the right amount of cold water is added to cool the drain water to the desired temperature set on the valve. Valve range is to 0 F.. Regulator Valve has composition seat to ensure tight shut-off when not blowing down. Valve should be protected with C.. Strainer with.0 mesh.. CWI = cold water inlet size.. DS Same as DF Without Flanges. Figure H-. Model D Dimensions H-

Section H Blowdown Separators For Screwed or Beveled Connections, Factory Fabricated " x " x /" Angle Permissible Load 000 lbs If DF, DS, or 0AO Aftercooler is furnished with separator, see dimension chart for separator height A. A dimension is determined by separator drain size D. This provides adequate height for the aftercooler and elbow when required. A dimension will always be " when separator is furnished without an aftercooler. D A -/ 0 For Flanged Connections Factory Fabricated " x " x /" Angle Permissible Load 000 lbs. If DF, DS, or 0AO Aftercooler is furnished with flanged connections on both ends, use dimension chart to determine separator height "A". "A" dimension will always be " when separator is furnished without an aftercooler. D A -/ 0 Figure H-. Separator Floor Stand H-9

Blowdown Separators Section H STRAP TYPICAL -/ SEPARATOR WALL BRACKET X X /" ANGLE USE MODEL 0 W/0" SEPARATOR USE MODEL W/" SEPARATOR USE MODEL W/" SEPARATOR MODEL A B C D 0 0-0 - - - NOTE:. DIMENSION C IS FOR MODEL ONLY.. DIMENSION D IS FOR MODEL 0 ONLY. Figure H-. Separator Wall Bracket H-0

Section H Blowdown Separators Sample Specifications PART GENERAL. GENERAL The following sample specification is provided by Cleaver-Brooks to assist you in meeting your customer s requirements. PART PRODUCTS. EQUIPMENT A. Blowdown Separaator. Furnish and install Cleaver-Brooks Model blowdown separator with I=, D=, V=, and plate thickness.. The separator shall be manufactured in accordance with ASME Code for 0 psig design and tested to 7 psig.. Provide separator with National Board stamping and "U" symbol. (Necessary in Michigan and Utah, optional elsewhere.). The separator shall be furnished with (screwed, weld bevel, 0# flanged or 00# flanged) connections.. The separator shall include a stainless steel striking plate at the point of inlet impingement and shall be furnished by Cleaver- Brooks. B. Accessories. Provide a solenoid valve to automatically control the flow of cold water by responding to temperature changes sensed at the thermostatic bulb in the aftercooler fitting.. Furnish a bi-metal thermometer with necessary adaptor bushing for use with (DF or 0AO) aftercooler.. Furnish a cast iron strainer with.0 stainless steel screen ahead of the (TRV or solenoid valve) to protect said valve against foreign matter.. Furnish and install an automatic drain water aftercooler, Model (DF or 0AO) with a cold water connection for a (TRV or solenoid valve and thermostat) (See Figure H- or Figure H-).. Provide a temperature regulator valve to automatically control the flow of cold water by responding to temperature changes sensed at the thermostatic bulb in the aftercooler fitting.. The accessory separator floor stand and wall mounting bracket are shown in Figure H- and Figure H-. H-

Blowdown Separators Section H NOTES H-