Installation. SS-2N TouchTime (Standard and Wall-Hung) Table of Contents. Express Lavatory System SS-Series

Similar documents
Installation. SS-3N Infrared (Standard and Wall-Hung) Table of Contents. Express Lavatory System SS-Series

Installation SS-3N/IR/STD SS-3N/IR-WH. Express Lavatory System SS-Series. Table of Contents

Installation CRS-2/IR, CRS-3/IR WARNING IMPORTANT. Table of Contents. Express Crescent Lavatory System CRS-Series

DISCONTINUED. Installation. SS-2N/ndt/STD SS-2N/ndt/WH. Express Lavatory System SS-Series. Table of Contents

Installation. MG-2 TouchTime. Express Lavatory System - MG Series with TouchTime Metering. Table of Contents

For Service Only. Installation Instructions. SS-3/AZ/WH97 Express Lavatory System SS-Series

Installation Instructions OBSOLETE

Installation MG-2/IR. Express Lavatory System - MG Series with Adaptive Infrared Control. Table of Contents

For Service Only. Installation Instructions SS-3/IR/WH97. Express Lavatory System SS-Series

Terreon Lav Decks WARNING

For Service Only. Installation Instructions EXD-2/STD EXD-2/JUV. Express Deck Lavatory System EXD Series

For Service Only. Installation Instructions EXD-3/WH97. Express Deck Lavatory System EXD Series

Installation LD3060. OmniDeck Series. Table of Contents Rev. R; ECM Bradley Corporation Page 1 of 10 3/30/11

DISCONTINUED. Installation LD OmniDeck Series. Table of Contents

Installation LVSD2. Table of Contents. Verge Lavatory System LVS-Series with Evero Natural Quartz Material

WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

Terreon WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

Installation LC800. Patient Care Unit, 47", Fixed Water Closet. Table of Contents

Installation LVAD2. Table of Contents. Verge Wash Basin LVA-Series with Evero Natural Quartz Material

LVRD3. Verge Lavatory System LVRD-Series with Evero Natural Quartz Material WARNING

Installation LVRD1 IMPORTANT! Verge Lavatory System LVRD-Series with Evero Natural Quartz Material. Table of Contents

Installation TDB3105 IMPORTANT! Table of Contents. Terreon 36" Circular Deep Bowl Washfountain with Infrared Control

Installation TDB3103 WF3203. Table of Contents. Terreon 36" Semi-circular Deep Bowl Washfountain with TouchTime Control

Terreon WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

LA90 DISCONTINUED IMPORTANT!

Installation TDB3104 WF3204. Table of Contents. Terreon 54" Semi-Circular Deep Bowl Washfountain with TouchTime

LA45 DISCONTINUED IMPORTANT!

LA60 DISCONTINUED IMPORTANT!

Installation LC840. Patient Care Unit, 40", Fixed Water Closet. Table of Contents

Installation. S Series Navigator Thermostatic Mixing Valve

WARNING NOTICE. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi. IMPORTANT

WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

Installation Instructions

Installation IMPORTANT! Bradley Multi-Station Wall Sink

Installation LVQD2. Table of Contents. Verge Lavatory System LVQ-Series with WashBar Technology

SS-3N Express Lavatory System SS-Series

Models: FM FM WARNING

Installation LVQD1. Table of Contents. Verge Lavatory System LVQ-Series with WashBar Technology

Installation Instructions

Installation Instructions

Installation S

Installation S

Installation S

Installation S

MERIDIAN MODEL# 3793

Installation S

Installation S HL2X2 High Capacity Manifold System. Table of Contents Rev. B; ECN Bradley Page 1 of 8 11/10/2014

Express Lavatory System SS-Series

Installation S IMPORTANT! Bradley Thermostatic Mixing Valve for Individual Showers. Table of Contents

Installation WARNING SXWS9561. Stainless Steel Panel Shower

Installation Instructions

WF3204. Extra Height 54" Terreon Semi-Circular Washfountain. Specifications

SS-1N Express Lavatory System SS-Series

Installation Instructions

INSTALLATION INSTRUCTIONS

WF2503, WF2504, WF2505, WF2508 Terreon Classic Washfountains

Installation Instructions

Installation Instructions

FL-2H, FL-2L Frequency Lavatory System FL-Series

PAT BASIN MODEL 9121, 9131, & 9141

Installation Instructions

Installation Instructions

SN2003, SN2023, SN2004, SN2024 Sentry Semi-Circular Shallow Bowl Washfountain

SS-2N Express Lavatory System SS-Series

TDB3104. Terreon 54" Semi-Circular, Deep Bowl Washfountain

INSTALLATION INSTRUCTIONS

? Teflon Tape? 9/16 Fixture Wall Anchors and. ? 9/32 Fixture Wall Anchors and

INSTALLATION INSTRUCTIONS

Installation & Operation Manual

Installation & Operation Manual

AV30 Advocate Lavatory System AV-Series

ESS-2200 Double Station Scrub Sink. with Two Sensor Operated Gooseneck Spout. ESS-3200 Deluxe Double Station Scrub Sink

INSTALLATION AND CARE GUIDE MARCO VANITY FRAME BASE & SINKTOP E E E E052463

EDGEMERE DUAL CONTROL WIDESPREAD LAVATORY FAUCET INSTALLATION INSTRUCTIONS

TDB3105 Terreon 36" Circular, 7-1/2" Deep Bowl Washfountain

A112408B/S-VR-UBL TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER: Technical Assistance Fax:

SN2013, SN2033 Sentry Corner Shallow Bowl Washfountains

SN2005, SN2008 Sentry Circular Shallow Bowl Washfountain

INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

Cooler Mounted Bottle Fillers

SN2003, SN2023, SN2004, SN2024 Sentry Semi-Circular Shallow Bowl Washfountain

WF Model Classic Washfountains Pre-Assembled Semi-Circular and Circular with 9" Deep Bowl

A132.8 Series Barrier Free, Wall Mounted Electric Drinking Fountain

SUBCOURSE EDITION EN US ARMY ENGINEER SCHOOL PLUMBING FIXTURES (PLUMBING IV)

A152.8 Series Barrier Free, Bi-Level, Wall Mounted Drinking Fountain

LD-5010 OmniDeck with WashBar 5000 Series

INSTALLATION INSTRUCTIONS. Cubix Widespread Faucet Part #: 3204, 5204, 3304, 5304 HANDLE STYLES

Installation Instructions

WF2613 Classic Corner Washfountain with 9" Deep Bowl

Sloan AQUS Installation Instruction, Operation, and Maintenance Guide

Ligature Resistant Sensor Faucet Patent # US D635,386 #SAL-5011/SF370

INSTALLATION INSTRUCTIONS

GRANITE COMPOSITE SINK

AV60 Advocate Lavatory System AV-Series

WELLWORTH WATERGUARD VITREOUS CHINA SIPHON JET TOILET

RESIN FREESTANDING TUB

REVIVAL LITE VITREOUS CHINA REVERSE TRAP TOILET

SAN RAPHAEL PRESSURE LITE VITREOUS CHINA SIPHON JET TOILET

MINIATURE THERMOSTATIC VALVE

Installation & Operation Manual

Transcription:

SS-2N TouchTime (Standard and Wall-Hung) Express Lavatory System SS-Series SS-2N with TouchTime activation, standard frame and liquid soap dispenser Express Lavatory Systems are ADA and TAS compliant U.S. Pat. Nos. 5,611,093, 5,369,818, D398,969 Other Patents Pending SS-2N with TouchTime activation, wall-hung frame and liquid soap dispenser Table of Contents Pre-Installation Information...2 Components...3 Supplies Required...4 Dimensions...4 5 Rough-Ins...6 Mount Frame to Wall...7 Install Bowl...7 Connect the Supply...8 Install Drains...9 Connect Electrical and Sprayhead Supplies...9 Mount TouchTime Modules...10 Adjust the TouchTime Modules...10 Adjust Temperature...10 TouchTime Assembly and Solenoid Valve Access...11 Solenoid Valve Troubleshooting...12 Navigator Mixing Valve Troubleshooting...13 Stop Valve Troubleshooting...14 Cleaning and Maintenance for Terreon...14 Soap Dispenser Maintenance...15 215-1499 Rev. K; ECN 17-08-010 2017 Bradley Page 1 of 15 4/24/2017 P.O. Box 309 Menomonee Falls, WI 53052 USA 800 BRADLEY (800 272 3539) +1 262 251 6000 bradleycorp.com

Installation WARNING Make sure that all water supply lines have been flushed and then completely turned off before beginning installation. Debris in supply lines can cause valves to malfunction. Turn OFF electrical power to the electrical outlets, then unplug all electrical units prior to installation. Electrical power MUST remain off until installation is complete. After installation is complete, turn on the water supply first, then turn on the electrical power. Hardware supplied by installer must be appropriate for wall construction. Wall anchors must have a minimum pull-out rating of 1,000 lbs. Follow appropriate dimensions for standard or juvenile height based on configuration and required rim height. Overtightening fasteners can damage the Terreon material. Use caution when tightening bowl and sprayhead fasteners. IMPORTANT Read this entire installation manual to ensure proper installation. When finished with the installation, file this manual with the owner or maintenance department. Compliance and conformity to local codes and ordinances is the responsibility of the installer. Product warranties may be found under "Products" on our Web site at www.bradleycorp.com. Separate parts from packaging and make sure all parts are accounted for before discarding any packaging material. If any parts are missing, do not begin installation until you obtain the missing parts. 2 4/24/2017 Bradley 215-1499 Rev. K; ECN 17-08-010

Components Sprayhead Cover (SS-2N-COVR-ONLY) Contact your local Bradley Rep for part number. Bolt, 5/16-18 (160-371) Screw, 10-24 (160-386) Sprayhead Body (SS-2N-SPYD-ASSY) Contact your local Bradley Rep for part number. Bowl (SS-2N-BOWL) Contact your local Bradley Rep for part number. Washer (142-002BJ) LockWasher (142-002BK) Nut, 5/16-18 (161-036) Panel Fasteners (160-450) Washers (142-002CA) (6) Places Main Frame (S17-325) Access Panel, Coal (186-1455B) Scuff Base Panel, Coal (185-034B) Scuff Base (17-326) (used with standard height frame only) Scuff Panel Fasteners (160-450) Washers (142-002CA) (4) Places Drain Assembly #8-32 Screw (160-319) Drain Plug (P16-072) Strainer (P16-075) Power Adapter (261-147A) 1/8" Rubber Washer (125-001DP) Bowl Mounting Hardware Polypropylene P-Trap (269-1697) Optional Chrome Plated Brass P-Trap (S29-094) Tailpiece (129-056) 1/4"-20 x 1/2" Pan Head Screw (Qty 2) (160-389) 1/4"-20 Washer (Qty 2) (142-002DB) Bradley 215-1499 Rev. K; ECN 17-08-010 4/24/2017 3

Installation Supplies Required (6) 3/8" wall anchors, bolts and 1" min. O.D. washers to mount main frame and bowl to wall (minimum pull-out rating of 1,000 lbs.) STD. HEIGHT ONLY: (2) 3/8" wall anchors, bolts and 1" min. O.D. washers to mount scuff base to wall 1/2" nominal copper tubing for hot and cold supplies and 1-1/2" NPT drain piping 120V/220V 50/60 Hz power source using Bradley supplied 120VAC/12V DC plug in adapter Dimensions - Front and Top Views Top View 50" (1270mm) 8-5/8" (219mm) 8" (203mm) Radius 15" (381mm) 15" (381mm) 10" (254mm) Radius Front View Standard Frame 38-1/4" (972mm) 7" (178mm) 21-1/4" (540mm) 30" (762mm) 36" (914mm) Front View Wall-Hung Frame 38-1/4" (972mm) 7" (178mm) 30" (762mm) 36" (914mm) 4 4/24/2017 Bradley 215-1499 Rev. K; ECN 17-08-010

Dimensions - Side Views (mm) Standard Height 21-1/8" (537) 11-1/2" (292) Wall Hung Mounted at Standard Height 21-1/8" (537) 11-1/2" (292) 38-1/2" (978) 34" (864) 30" (762) 13-1/4" (311) 8-5/8" (219) 3" (76) Scuff Base on Standard Height Only 38-1/2" (978) 34" (864) 30" (762) 13-1/4" (311) 8-5/8" (219) Wall Hung Mounted at Juvenile Height Ages: 6 through 12 35-1/2" (902) 31" (787) 27" (686) 21-1/8" (537) 11-1/2" (292) 8-5/8" (219) 10-1/4" (260) Wall Hung Mounted at TAS Height Grades: 6 through 8 or 9 21-1/8" (537) 11-1/2" (292) Wall Hung Mounted at TAS Height Grades: Pre-K through 5 or 6 21-1/8" (537) 11-1/2" (292) 36-1/2" (927) 32" (813) 28" (711) 8-5/8" (219) 34-1/2" (876) 30" (762) 26" (660) 8-5/8" (219) 11-1/4" (286) TAS 9-1/4" (235) TAS Bradley 215-1499 Rev. K; ECN 17-08-010 4/24/2017 5

Installation 1 Rough-Ins 23-1/2" (597) 23-1/2" (597) 13-1/4" (337) A B 9-3/8" (238) 3" (76) 9-3/8" (238) 4" (102) B A D1 4" (102) D2 E J 32" (813) 28-3/4" (730) 25-3/4" (654) B B 20" (508) 15" (381) Floor C C 3-1/2" (89) CODE DESCRIPTION QTY. A 3/8" Wall Anchors with a minimum pull-out force of 1,000 lbs. for Bowl 2 B 3/8" Wall Anchors with a minimum pull-out force of 1,000 lbs. for Mainframe 4 C 3/8" Wall Anchors for Base Frame, Standard Frame option only, minimum pull-out force not required 2 D1 1/2" nominal copper tubing for Cold Supply, stub-out 2" from wall 1 D2 1/2" nominal copper tubing for Hot or Tempered Supply, stub-out 2" from wall 1 E 1-1/2" NPT Drain, stub-out 2" from wall 2 F On the bowl back, measure the distance between the 3/4" bowl mounting holes. Divide this measurement in half. Measure and mark this dimension on the wall to the left and the right of the centerline. Install two 3/8" wall anchors with a minimum pull-out rating of 1,000 lbs 2 (supplied by installer) at locations marked. J 110v GFI Protected Electrical Outlet 1 RIM HEIGHT VERTICAL HEIGHT ADJUSTMENTS FOR CODES A E, H, C and W FIXTURE STYLE 34" None Standard Height 34" None Wall-Hung 32" Subtract 2" TAS, Grades 6 through 8 or 9 31" Subtract 3" Juvenile Height 30" Subtract 4" TAS, Pre-K through Grades 5 or 6 6 4/24/2017 Bradley 215-1499 Rev. K; ECN 17-08-010

2 Mount Frame to Wall Anchoring the frame to a wall that is not flat may cause the frame to bend, making it difficult to reinstall the access panels. If necessary, use shims to compensate for wall distortion. Using a T20 torx key, remove the fasteners securing the access A panel to the main frame, and remove the panel. Once the frame is level and flat against the wall or shimmed, mount the frame B to the wall at four places using 3/8" bolts and 1" min. O.D. washers. When mounting the standard height frame, mount the scuff base to the wall at the same time using two additional 3/8" bolts and washers. 3 Install Bowl The sprayhead body has slotted holes for adjusting the fit-up with the bowl and wall. The tailpiece on the waste tee has been rotated upward for shipping purposes. Turn the tailpiece down to its proper position before installing the bowl Attach the bowl to the frame with 1/4"-20 x 1/2" pan-head screws A and washers. Do not tighten. Secure the bowl to the wall anchors with 3/8" bolts and 1" min. O.D. B washers, two places. Do not overtighten. Tighten the pan-head screws. C DO NOT OVERTIGHTEN. Bradley 215-1499 Rev. K; ECN 17-08-010 4/24/2017 7

Installation 4 Connect the Supply - Hot and Cold Supply The letter H on the Navigator Mixing Valve indicates hot water supply inlet. C Connect one end of each hose to the Navigator valve (one on the hot side, one on the cold side). Connect the other swivel end to the stop valves. A Loosen but do not remove the two mounting screws holding the valve bracket to the frame. Slide the valve bracket up and lift it from the frame. Attach the stops to the hot and B cold water wall stub-outs. 4b Connect the Supply - Single Tempered Supply C Connect one end of flexible hose to the tempered line adapter. Connect the other swivel end to the stop valve. A Loosen but do not remove the two mounting screws holding the valve bracket to the frame. Slide the valve bracket up and lift it from the frame. Attach the stop to the tempered B wall stub-out. 8 4/24/2017 Bradley 215-1499 Rev. K; ECN 17-08-010

5 Install the Drains To Drain Stub-Out 6 Connect Electrical and Sprayhead Supplies WARNING The Express control must be connected with the 120VAC/12V DC plug in adapter. Not using the provided adapter can cause personal injury and will result in damage to the electronics. Left Button Right Button TouchTime Module A Loosen the compression nuts. Push the sprayhead supply tubes firmly into the tube connectors until they are fully seated. Tighten the compression nuts by hand. Green Supply Tube (From Sprayhead) Red Supply Tube (From Sprayhead) Connect plug-in D adapter to splitter. Compression Nut Connect splitter connector to B TouchTime module. Connect button connector to C TouchTime module. Plug-In Adapter (261-147A) Splitter Connect valve connector to D TouchTime module. Activation of the push button takes place only when it is released, thereby preventing hold open activation. Bradley 215-1499 Rev. K; ECN 17-08-010 4/24/2017 9

H Installation 7 Mount TouchTime Modules Secure (2) TouchTime modules with hook and loop fasteners to frame in A approximate locations shown. 8 Adjusting the TouchTime Module The TouchTime module is set at the factory with the selector switch in position 5. This provides a 15 second time out period. The 24 hour flush function will activate water flow for a period of 60 seconds any time there has been no activation within the past 24 hours. This function is used to help clear stagnant water from the plumbing system and can provide some measure of prevention against the formation of bacteria in supply pipes. LED Indicator To adjust the TouchTime module to a different time out period, turn the selector switch to A the desired time out setting (4 through 9 for no flush, A though F for 24 hours flush) as indicated on the module label. Pushbutton Connectors (Can use either one or both) Selector Switch Power Connection 9 Adjust the Temperature WARNING This valve is NOT factory preset. Upon installation, the temperature of this valve must be checked and adjusted to ensure delivery of a safe water temperature. Water in excess of 110 F (43 C) may cause scalding. A Loosen Cap Screw about 1/4" (4-6 turns) and lift up cover (do not remove). B Using cover, turn cartridge gently until desired water temperature is reached. Do not turn past stops as this may damage unit. Push cover down and tighten screw. C C Reinstall the valve bracket. Turn on the water supply and check for leaks. Turn on the electrical power, trigger the TouchTIme pushbutton of each station until all air is purged from the lines and water is flowing smoothing. Reinstall the access panel. 10 4/24/2017 Bradley 215-1499 Rev. K; ECN 17-08-010

TouchTime Assembly and Solenoid Valve Access To access TouchTime switch: 1. Remove the Phillips-head screws located in the bottom of the sprayhead body. 2. Lift the Terreon cover/shelf off. To reinstall sprayhead cover/shelf: 1. Position the cover/shelf on the sprayhead body. 2. Secure it to the sprayhead body using the screws provided. Sprayhead Components PushButton Bracket (140-956) Nut (Included with Switch) TouchTime Mechanical Switch (S83-368) TouchTime Piezo Switch (S83-369) (Not Shown) Aerator Assembly (S05-180) Bradley 215-1499 Rev. K; ECN 17-08-010 4/24/2017 11

Installation Troubleshooting Solenoid Valve: Part nos. S07-067-DC (closed body) & S07-067A-DC (thru body) Turn off water supplies to the unit before troubleshooting. Item Qty. Part No. Description 1 1 118-334 Valve Body, ¼" Closed 1 1 118-334A Valve Body, ¼" Thru 2 1 S27-352 12VDC Valve Cartridge 3 1 125-165 O-Ring, #2-013 2 3 1 Problem Cause Solution An individual operating station fails to shut off and drips. Internal cartridge failure. Replace S27-352 cartridge. An individual operating station fails to turn on. A failed cartridge for the valve or loose electrical connection to the terminal. Test the station to determine the cause. 1. Disconnect the wires from the cartridge of an adjacent valve. Disconnect the wires from the problem valve and reconnect to the adjacent valve. 2. Turn on electrical and water supplies to the unit. Activate the pushbutton/piezo switch on the problem station, and the adjacent station should turn on. If the adjacent station turns on and cycles normally, replace the cartridge on the problem valve. If the adjacent valve fails to turn on, inspect the wires from the pushbutton/piezo switch assembly and do the following: make sure there are no breaks and that the fully insulated disconnect terminals are firmly crimped in place; turn off the electrical and water supplies; reconnect to the adjacent valve and turn on the water supplies to the unit; activate the pushbutton/piezo switch. If the station still fails to turn on, replace the pushbutton or piezo switch assembly. 12 4/24/2017 Bradley 215-1499 Rev. K; ECN 17-08-010

Thermostatic Mixing Valve Troubleshooting Before attempting to troubleshoot the valve or disassemble the components, check for the following conditions: If stop valves are used, make sure that they are fully open. Make sure that the hot and cold inlet pipes are connected properly, and that there are no cross-connections or leaking stop valves. Check the hot water heater output to make sure that it is at least 10 F above the set temperature. Be sure to close the appropriate shut-off valves prior to disassembly of the valve and reopen the valves after inspection and repair is complete. Problem Cause Solution External leaks. Damaged cartridge or O-rings. Replace cartridge with part number 269-1927 Improper water Hot water supply is not 10 above desired set point. Increase hot water supply temperature temperature or temperature fluctuation. Valve temperature is not properly set. Adjust the temperature as shown on page 7, step 10. Limited water flow. Dirt and debris have built up in the valve or strainer. 1. Check to make sure both hot and cold supplies are connected to the Navigator mixing valve and that they have water flow. 2. Remove cover and U-clip. Remove the cartridge and clean the strainer. It is not required to grease cartridge, however if desired, use silicone grease only. Do not use grease on check valves. 2 3 1 Parts List Item Part No. Description Quantity S59-4000 1 160-463 Cap Screw 1 2 107-582 Cover 1 3 269-1927 Thermostatic Cartridge 1 4 198-014 Check Valve* 2 5 132-051 Retaining Ring* 2 6 118-319 Valve Body 1 7 146-079 U-Clip 1 * Included with Prepack S65-326 4 5 Tempered Line Adapter Option Part no. S39-804 (replaces S59-4000 if tempered line is used) Strainer (173-028) 5 4 6 7 Bradley 215-1499 Rev. K; ECN 17-08-010 4/24/2017 13

Installation Stop Valve Troubleshooting Problem Cause Solution Water dribbles or does not flow from the sprayhead. Stop Valves may not be functioning properly. 1. Close the stops and inspect the valves that supply water to the lavatory system. 2. Inspect the stop valves to see that they have been properly installed. Sprayhead delivers ONLY hot OR cold water. Stop Valves may not be functioning properly. 1. Close the stops and inspect the valves that supply water to the lavatory system. 2. Inspect the stop valves to see that they have been properly installed. 3. Inspect the thermostatic mixing valve for proper installation and connection to hot and cold supplies. Cleaning and Maintenance for Terreon Material Description: Terreon is a densified solid surface material composed of bio based resin and is resistant to chemicals, stains, burns and impact. Surface can be easily repaired with everyday cleansers or fine grit abrasives. Because Terreon is a unique cast material, its aggregate flow and distribution, and shades of color can vary from product to product creating natural characteristics. Routine Cleaning: For regular cleaning, use mild neutral base cleaners. Stubborn Stains: Remove tough stains with Soft-Scrub and a green Scotch-Brite pad or lightly sand in a circular motion with 240 grit wet/dry sandpaper. The finish can then be renewed with a maroon Scotch-Brite pad. Scratches: Remove scratches with a green Scotch-Brite pad. The finish can then be renewed with a maroon Scotch-Brite pad. Hard Water Deposits: Remove hard water deposits with a mild solution of vinegar and water. Always rinse the unit thoroughly after cleaning. Restoring the surface: Use Hope s Perfect Countertop to refresh and protect the Terreon Solid Surface material. Dark Terreon colors may require additional care and maintenance. For complete instructions on this additional maintenance, visit bradleycorp.com. Repair Kits: Terreon repair kits are available. Contact your Bradley representative or distributor for part numbers and pricing. Repair kits are made to order and have a shelf life of 30 days. NOTICE! Do not use strong acid or alkaline chemicals and cleaners to clean Terreon. If these chemicals come in contact with the surface, wipe them off immediately and rinse with soapy water. Avoid contact with harsh chemicals such as paint remover, bleach, acetone, etc. Avoid contact with hot pans and objects. Brand Names Use of brand names is intended only to indicate a type of cleaner. This does not constitute an endorsement, nor does the omission of any brand name cleaner imply inadequacy. Many products named are regional in distribution, and can be found in local supermarkets, department and hardware stores, or through your cleaning service. It is emphasized that all products should be used in strict accordance with package instructions. 14 4/24/2017 Bradley 215-1499 Rev. K; ECN 17-08-010

Fill Soap Dispenser The soap valve will dispense vegetable/coconut oil liquid soaps, synthetic detergents, viscous lotion soaps, and antiseptic solutions. A 10-15% con cen tra tion is rec om mend ed for veg e ta ble or co co nut oil liquid soaps. Before filling, rinse out each soap tank with hot water to remove packing dust. Shake water out thor ough ly and allow to dry. do not overfill! Soap Tank Kits S65-291B (Coal) includes: Coal Tank w/valve (S11-220B) Leaf Spring (S39-350) Screw (160-385) Soap Valve Repair Kit (S65-258) (includes Nut, Spring, Washer and Plunger) Leaf Spring will engage when soap tank is pushed into place. Filler Hole Soap Blank Coal (133-143B) #10 Screw Clean Soap Dispenser NOTICE! Do not use abrasive cleansers to clean the soap tank. Abrasive cleaners can damage the surface. Regular cleaning of the soap dispenser is recommended to ensure optimum performance and maximum service life. Cleaning the soap dispenser monthly to remove soap residue, dirt, and other accumulations should become a regular part of your washroom cleaning routine and general maintenance program. Clean exterior: Use warm water and soap to clean the exterior of the soap dispenser. Dry with a soft cloth. Clean interior: Inspect the interior of the tank for residue or coagulation of soap. If necessary, clean the tank according to the following procedure: 1. Pour out any remaining soap in the tank. 2. Full the tank half-full of hot water and shake the tank to dislodge the soap residue. 3. Empty the water from the container and repeat steps 1 and 2 until the soap container is clean. If rinsing alone does not remove the soap residue, place a small chain (24 inches long) into the tank with hot water and shake the container until the chain dislodges the residue. Then remove the chain and rinse out the tank. Clean internal components: Pump hot water through the soap dispenser until a clean flow of water comes out of the valve. To change soap, pour out all of the soap from the dispenser and rinse with hot water several times until all residue is removed. Pump the valve until clean water appears. Rinse the dispenser with ethyl alcohol; air dry before refilling. Bradley 215-1499 Rev. K; ECN 17-08-010 4/24/2017 15