SF 6 -Leak Pointer Operating Manual (original version) Type-No.: R002

Similar documents
User Manual SF6 GASCHECK 6000

REFRIGERANT LEAK DETECTOR

Leak-Seeker I Refrigerant Leak Detector

CLI Refrigerant Gas Leak Detector. User s Guide

GERMANY TEC 'LOGY leak-detect EXPERT

TEK-Mate. Refrigerant Leak Detector

TEK-Mate. Refrigerant Leak Detector

Model C-380. Instruction Manual. Refrigerant Leak Detector. reedinstruments

D-TEK Select. Refrigerant Leak Detector

actoolsupply.com User Guide Extech RD300 Air Conditioning AC Refrigerant Leak Detector Refrigerant Leakage Detector Model RD300 actoolsupply.

6-1 Installing Batteries 6-2 Automatic Circuit/Reset Feature 6-3 Feature Sensitivity Adjustment

Instruction Manual Electronic Leak Detector. Bedienungsanleitung Elektronisches Lecksuchgerät. Mode d emploi Détecteur de fuites électronique

Refrigerant Leak Detector

RLD-H10P Refrigerant Leak Detector

Refrigerant / Combustibles Leak Detector

Model R9100. REED Instruments Instruction Manual. Ultrasonic Leak Detectortor

Model: LD5 Dual Mode Refrigerant Gas Leak Detector. Operating Instructions

LD-5000 REFRIGERANT LEAK DETECTOR

OPERATING INSTRUCTIONS

USER MANUAL MINITRACER PORTABLE SNIFFER

275HVD NON-CONTACT, HIGH VOLTAGE DETECTOR DETECTOR DE ALTA TENSIÓN SIN CONTACTO

NGD8800 USER S MANUAL

Carbon Monoxide Meter Model CO15. User Manual. Additional User Manual Translations available at

AIR CONDITIONNING 95 CODE 002

HIGH VOLTAGE A.C. PROXIMITY DETECTOR HI-PROX

99 Washington Street Melrose, MA Phone Toll Free Visit us at

Whisper. Ultrasonic Leak Detector

LD 5000 REFRIGERANT LEAK DETECTOR JB INDUSTRIES INC.

H-10PM. Refrigerant Leak Detector

Model: LD7 Dual Mode Refrigerant Gas Leak Detector. Operating Instructions

SENSIT HXG-2. Instruction Manual For use with combustible gases Gas Leak Detector

YELLOW JACKET. H 2 Tracer Gas Leak Detector. Operations Manual. Detects 5% H 2 in 95% Nitrogen Tracer Gas. Model 69341

LD920. User Manual. H2/N2 Tracer Gas Leak Detector. Detects 5% H2 in 95% Nitrogen Tracer Gas. Made in U.S.A. LeakDetectors-LD920-UserManual.

Model ATD Refrigerant Gas Leak Detector. User Manual. Detects all CFC, HFC, HCFC, HFO Refrigerants including blends

RLD-H10G Refrigerant Leak Detectors

Instruction Manual MSI Sensit HXG

AS 500. Instructions for Use. Version 1.0. December

III. 99 Washington Street Melrose, MA Phone Toll Free Visit us at OPERATING INSTRUCTIONS

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

ATD-3698 Refrigerant Gas Leak Detector. Owner s Manual

Lutron GS-5800 ULTRASONIC GAS LEAKAGE DETECTOR

Precision Infrared Thermometer. Users Manual

Operation Manual R205BV, R209BV

Jetstream Series HPLC - PELTIER COLUMN-THERMOSTATS 1. GENERALITIES

LD900. User Manual. Refrigerant Gas Leak Detector. Detects all HFO, HFC, HCFC, and CFC Refrigerants including blends. Made in U.S.A.

GASGUARD VENT LINE3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

II 2 G. SENSIT HXG-2d. Ex ib IIB T3 IP20. Suitable for combustible gases such as Methane, Butane, Propane and Natural Gas MADE IN USA

GAS-Mate. Combustible Gas Leak Detector

GG-VL-R REFRIGERANT VENT LINE SENSOR. Installation and Operation Manual

Tru Pointe Refrigerant Leak Detector Instruction Operation & Maintenance Rev. 0 April 2003

Operating Instructions. Model: LD3 Dual Mode Refrigerant Gas Leak Detector ROBINAIR.COM

TAG MR VOLTAGE DETECTORS AND ACCESSORIES. Instruction & Operation Manual

Operating instructions

SENSIT HXG-2d. SENSIT TECHNOLOGIES 851 Transport Drive Valparaiso, IN Phone: (219) Fax: (219)

For technical support call:

(Place Logo from Lab here)

Digital Refrigerant System Analyzer. MAXMIN Psi kpa Bar MPa C F R TIME P T UNITS

LEAK DETECTION INDUSTRY LEADING SENSITIVITY

Instruction Manual for FORMALDEHYDE GAS DETECTOR MODEL FP-30/FP-40

GASGUARD NH 3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

LD910. User Manual. Combustible Gas Leak Detector. Detects all Hydrocarbon and other Combustible Gases. Made in U.S.A. MSHA Approved Intrinsic Safety

SENSIT HXG-2d Combustible Gas Detector

SENSIT HXG-2d Combustible Gas Detector INSTRUCTION MANUAL Read and understand Instructions before use. PENDING Ex. II3G Ex ic llb T3 IP20

USER MANUAL ENVIRONMENTAL METER. Model EN510. Additional User Manual Translations available at

Aquamax KF Oil Evaporator. User Manual

HSGM Heißschneide-Geräte

INSTRUCTION MANUAL FOR RIKEN PORTABLE TOXIC GAS MONITOR

Dräger X-am 7000 Multi-Gas Detection

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

ADVISOR CD User Manual. Software from version: V

Safe Operation Manual. Honeywell IQ Force Gas Detector

UBS1RF OPTICAL SMOKE ALARM EN 14604:2005/AC:2008 DOP:UBS1RF-001-V1

Reacti-Therm I and III Heating Modules

Remote alarm unit Art. Nr.:

Wilcom. Model FR2 Fiber Ranger Optical Fault Locator OPERATING INSTRUCTIONS

RD99 REFRIGERANT GAS LEAK DETECTOR WARNING!

KFP-CF Series Operation Manual

EN-ENGLISH INSTRUCTION MANUAL. METPOINT LKD 300 Leak Detector (LD109) For leak detection in pneumatic systems.

testo 316-EX gas leak detector Instruction manual

testo Leakage detector for gas Instruction manual

Thermo 230 / 231 / 300 / 301 / Troubleshooting

INSTRUCTION MANUAL. Laboratory Equipment Pty Ltd Ph: Fax:

EVac II Programmable Digital Vacuum Gauge

User's Guide. Pinless Moisture/Humidity Meter with Memory + IR Thermometer. Model MO295

SAFETY PERSONAL AC VOLTAGE (50 or 60Hz) PROXIMITY DETECTOR

CA876 INFRARED K-THERMOMETER WITH LASER ENGLISH. User Manual. Auto OFF

Instruction manual EN

CD6102 / CD6102 OC / CD6102-2

YELLOW JACKET. ACCUPROBE UV and ACCUPROBE II Refrigerant Leak Detector with Heated Sensor. Instruction and Operation Manual

User Manual. TN1500 Embedding Center. Read Prior to Operation! Always keep this manual near the unit! WP

Operating Instructions. Accessory Units Melitta Cafina XT Series. Melitta Professional Coffee Solutions

ExStik DO600 USER GUIDE. Dissolved Oxygen Meter. 99 Washington Street Melrose, MA Phone Toll Free

MicrOTDR. Optical Fault Locator. User Manual

M-Sens 2. Online-Moisture Meter for Solids. Operating Instructions. SWR engineering Messtechnik GmbH

CAREFULLY READ THESE INSTRUCTIONS BEFORE USING SAFETY PRECAUTIONS USE OF EXTENSION CORDS

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

CERAMIC HEATER MODEL NO: DEVIL 350B 230V/110V OPERATING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS GC ISS 1

User Manual. Moisture Analyzer HE53

CA870 INFRARED THERMOMETER E N G L I S H. User Manual. Auto OFF

Operating Instructions for Reka Hot-Melt Glue Applicators

Transcription:

SF 6 -Leak Pointer Operating Manual (original version) Type-No.: 3-033-R002

Page 1. General information 3 1.1 Safety notes and symbols used 3 1.2 Obligation to exercise due care 4 1.3 Transport 4 2. Overview - SF 6 -LeakPointer 5 2.1 Technical data 5 2.2 Standard accessories 7 3. Description and operation of the device 8 3.1 Features 8 3.2 Operation features 9 3.3 Searching for Leaks 10 3.4 Operating tips 11 4. Maintenance 12 Please read this operating instruction before putting the device into operation. Thus operating faults can be avoided. In case of non-observance of the operating instruction the manufacturer cannot assume any liability or warranty. The copyright of this documentation remains with DILO Armaturen und Anlagen GmbH, D-87727 Babenhausen. Any use not permitted by the author (multiplication, leaving to third persons etc.) is subject to penalty and indemnification. www.dilo-gmbh.com C 3970-00 Page 2 / 12

1. General information 1.1 Safety notes and symbols used In the following operating manuals specific safety warnings are given in order to draw your attention to residual risks which cannot be avoided during the operation of the device. These residual risks contain dangers for Persons Product and machine The environment The symbols used in the operating manuals should draw your attention specially to the safety notes: Danger This symbol refers to risks for persons (danger to life, danger of injury) Warning This symbol refers to risks for machines, material and the environment. This symbol refers to electric shock The most important aim of the safety notes is to prevent personal injuries. If the warning sign Danger, appears, danger from machines, materials and the environment are not excluded. If the warning sign Warning, appears, there is no danger for persons. The corresponding symbol which is used cannot replace the text of the safety note. Therefore the complete text must always be read. This symbol is not for safety notes, but for information to understand the device better. www.dilo-gmbh.com C 3970-00 Page 3 / 12

1.2 Obligation to exercise due care The device has been designed and constructed bearing in mind the standards to be observed as well as additional technical specifications. Safe use of the machine can only be achieved if all the necessary measures are followed. The operator has to ensure that the SF 6 -LeakPointer is only used for the purposes for which it is intended. the SF 6 -LeakPointer is only operated in accordance with the instructions and in good condition and that the safety devices are regularly checked. complete and legible operating manuals are available on site. only qualified personnel operates or repairs the device. this personnel is regularly instructed in safety procedures and environmental protection and that this personnel is fully aware of the complete operating manuals and particularly in the safety notes. the safety and warning notes mounted on the SF 6 -LeakPointer are legible and not removed. Warning The parts inside the SF 6 -LeakPointer are under dangerous voltage. Therefore do not open the case in any case. 1.3. Transport The device should only be transported in the suitable box and transportation instructions of the local country have to be considered. Installation Warning Only operate the device indoors or in dry places outdoors. The ambient temperature during operation of the device should be in the range of -20 C to +50 C. www.dilo-gmbh.com C 3970-00 Page 4 / 12

2. Overview - SF 6 -LeakPointer The SF 6 -LeakPointer is the world s first truly automatic electronic SF 6 leak detector requiring absolutely no operation intervention during the leak search process. Controlled by an internal software, the SF 6 - LeakPointer continuously and automatically adjusts critical sensitivity related functions providing optimal leak searching results under any conditions. 2.1 Technical data SF 6 -LeakPointer Dimensions of the device: Length (L): 254 mm / 10 Width (B): 59 mm / 2.3 Height (H): 51 mm / 2 Weight: 0.5 kg / 1lbs. 2 oz. www.dilo-gmbh.com C 3970-00 Page 5 / 12

Dimensions with case: Length (L): 300 mm / 11.8 Width (B): 230 mm / 9.1 Height (H): 75 mm / 3 Weight with case and accessories: 1.2 kg / 2lbs. 9 oz. Dimensions of the probe: (metal flex) Length (L): 365 mm / 14 Diameter: 6.4 mm / 0.25 General data: Sensor: State of the art Cold Cathode Discharge Diode Response time T90: approx. 1s Recovery time: approx. 1s Ambient moisture: up to 90% relative moisture, non-condensing during operation Operating temperature: -20 - +50 C / -4 to 122 F Sensitivity: Fully automatic sensitivity selection with 6 visible LED range indicators. Maximum sensitivity allows detection of approx. 5 g/yr. Audible alarms: Two user selectable audible alarm options (High and low intensity alarm tones) www.dilo-gmbh.com C 3970-00 Page 6 / 12

Visual alarms: TACHOMETER bar graph display. Eight high intensity LEDs are arranged in a Tachometer-like display indicating leak intensity per sensitivity range. GEARSHIFT display is arranged in a gearshift pattern. Seven LEDs indicate the current sensitivity range of the unit and subsequent leak size as follows: GEAR --- LEAK SIZE N --- No Leak 1 & 2 --- Small 3 & 4 --- Medium 5 & 6 --- Large Power: Three size C alkaline batteries (NEDA/ANSI 14A) Continuous Operating battery life at 25 C (77 F): High intensity alarm: 55 hrs Low intensity alarm: 75 hrs Because the instrument turns itself off after 10 min. of inactivity, the actual useful battery life may be longer than stated. See Maintenance section for LO BAT conditions. 2.2 Standard accessories 1 Carrier case 3 1.5 V alkaline batteries 1 Spare sensor 1 Operating manual (multilingual) on CD-ROM www.dilo-gmbh.com C 3970-00 Page 7 / 12

3. Description and operation of the device 3.1 Features The main features of the SF 6 -LeakPointer are: First truly automatic electronic leak detector. High sensitive SF 6 detection. Patented microprocessor controlled circuitry. Exclusive software controlling automatically all sensitivity related settings, simplifying user operation. New state of the art Cold Cathode Diode (CCD). Superior resistance to background contaminants. Exclusive TACHOMETER style LED leak indicators. Rugged, ergonomically correct housing fits comfortably in your hand. Up 75 hours and more of battery life with auto off feature. Includes hard case, spare CCD sensor and 3 size C alkaline batteries. Certified to CE High Output Alarm Speaker 8 LED Tachometer Display Enables user to pinpoint the exact location of a leak source. LED display for Leak Sizing Allows user to determine the approximate size of a leak. One Button Operation For reset, change audible alarm, and shut off. www.dilo-gmbh.com C 3970-00 Page 8 / 12

3.2 Operation features TURNING THE INSTRUMENT ON Click the START button once to turn the unit ON. RESETTING THE INSTRUMENT At any time during operation, clicking the START button resets the instrument to its highest sensitivity level and balances it to ambient conditions. SWITCHING AUDIBLE ALARMS The SF 6 -LeakPointer incorporates two user selectable audible alarm sounds. At any time during operation, simply double click the START button to toggle between the two audible alarm options. The instruments will store the current alarm setting when turned OFF, thus becoming the operation alarm the next time the instrument is powered on. TURNING THE INSTRUMENT OFF At any time during operation, press and hold down the START button until the LED display turns OFF. This indicates that the unit has been shut down. SENSOR STATUS INDICATOR If the sensor is damaged, every other one of the tachometer LED s will light up visibly notifying the user of the problem, and then the instrument turns itself OFF. LOW BATTERY INDICATOR When the batteries reach approximately 10% of capacity, the rightmost tachometer LED will stay lit above the LO BAT legend. www.dilo-gmbh.com C 3970-00 Page 9 / 12

CONTROL Single momentary push-button operates all functions of the unit: With the instrument OFF, click the START button once to turn it ON. The instrument is automatically calibrated and ready to search for leaks. With the instrument ON, holding the button down for 3 seconds turns the instrument OFF. Audible alarm settings remembered. With the instrument ON, double clicking the button changes the audible alarm from high to low intensity and vice versa. With the instrument ON, clicking the button once resets the instrument to maximum sensitivity and nulls out any ambient contamination. 3.3 Searching for Leaks The SF 6 -LeakPointer is fully automatic and need only be turned on to begin a leak search. All necessary sensitivity and calibration settings are automatically selected by the installed software providing optimal leak searching performance under any conditions. Recommended Leak Search Procedure Notes: Take care not to contaminate the detector probe tip if the part being tested is contaminated. If the part is particularly dirty, or condensate (moisture) is present, it should be wiped off with a dry shop towel or blown off with shop air. No cleaners or solvents should be used, since the detector may sensitive to their ingredients. Visually trace entire SF 6 -filled equipment to be investigated and look for signs of damage and corrosion on all components. Each questionable area should be carefully checked with the detector controls, service points with caps in place, brazed or welded areas, and areas around attachment points and hold-down on lines and components. Always follow the SF 6 -filled equipment around in a continuous path so that no areas of potential leaks are missed. If a leak is found, always continue to test the remainder of the equipment. At each area checked, the probe should be moved around the location at a rate no more than 25 to 500 mm/s (1-2 in/s), and no more than 5 mm (0.2 ) from the surface, completely around the position. Slower and closer movement of the probe greatly improves the likelihood of finding a leak. www.dilo-gmbh.com C 3970-00 Page 10 / 12

3.4 Operating Tips UNDER WINDY CONDITIONS Locating leaks under windy conditions may severely impede the leak searching process. Even very large leaks may be impossible to find as the escaping gas is quickly dissipated into the atmosphere. If necessary, fabricate a gas trap using foils around joints or fittings or otherwise shield the search area from the wind. WHEN TO RESET THE UNIT It is necessary to reset the SF 6 -LeakPointer during a leak search if the unit becomes fully saturated, multiple leaks are present or during the leak verification process. LEAK VERIFICATION If a suspected leak is indicated, verify several times by moving the sensor away from the leak area, resetting the unit and then back to the suspected leak. If the instrument indicates a leak three consecutive times, then you have found a leak. www.dilo-gmbh.com C 3970-00 Page 11 / 12

4. Maintenance The SF 6 -LeakPointer is designed to require a minimal amount of field maintenance. Periodic replacement of the unit s sensor and batteries are the only maintenance needs: LOW BATTERY CONDITION: When the batteries reach approximately 10% of capacity, the rightmost LED of the tachometer indicator (above the LO BAT symbol) will energize. The other seven LEDs will continue to function as indicators of the leak s relative size. CHANGING THE CCD SENSOR: The CCD sensor assembly consists of metal and plastic components. Do not attempt to remove one component from the other. Do not use solvents or cleaning solutions for cleaning the sensor. It should be replaced when air vents become clogged. Eventually, the sensor will need to be replaced. This condition is usually indicated by abnormal or erratic performance. With the unit OFF, the old sensor can be removed by screwing off and the new one can be screwed on afterwards. DILO recommends that you always have a spare sensor available for replacement in the field. Warning Only authorized personnel should carry out maintenance works in accordance with maintenance instructions and regulations for the prevention of accidents. In case of non compliance this could result in considerable damage to the equipment. www.dilo-gmbh.com C 3970-00 Page 12 / 12