Operating Instructions Bühler Infrared Heater POWERCUBE IRB 6. These operating instructions are protected by copyright. Modifications reserved.

Similar documents
INSTRUCTION MANUAL MNBX14

FastGene Plate Centrifuge. Instruction Manual. Catalog No. NG

INSTRUCTION MANUAL. Stirring hotplate (with probe and stand) Brand : (Dragon laboratory)

Instruction Manual. Model AccuPlate Hotplate AccuPlate Stirrers AccuPlate Hotplate Stirrer 12/10 CLS-EQ-LHP01REV

Trumatic E. Trumatic E 2400 (Australia) Operating instructions Page 4 Installation instructions Page 7. To be kept in the vehicle!

Dry Bath Heating Systems

Operating Manual. VIENNA Hot Display

Short Path Distillation Unit. KDL 1 BASIC Version 2015

Waste water ejection unit

User Manual. MS7-H550-Pro MS7-H550-S MS7-Pro MS7-S

Edition 8 From serial no Publ. no OM 5030NHD; Orwak 5030-NHD OPERATING INSTRUCTIONS (IN THE ORIGINAL)

L / -014L / -015L

HSGM Heißschneide-Geräte

Instruction manual. Water treatment Boiler system D 30 L

INSTRUCTIONS AND WARRANTY

Light oil / kerosene burner

SAFEVIEW-MINI2 TRANSILLUMINATOR

TIH 300 S / TIH 400 S / TIH 500 S / TIH 700 S / TIH 900 S / TIH 1100 S

Aluminum Heating Mantles

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P

Magnetic Stirrer BIOSYSTEM DIRECT BIOSYSTEM Operating Manual Issue

MANUAL Oil Level Sensor

Appearance and sensing characteristic Specification (temperature range) Model 10 to 70 C ES1B. 2 mm 20 mm 40 mm 60 mm. 40 dia. 60 dia.

Operation Manual R205BV, R209BV

Instruction manual ASPIMAX 16

Instruction Manual M6627 / Version 7.4. Slide Drying Bench MH6616 MH6616X1

OPERATING MANUAL. BAK Thermoplastic Welding Technology AG 1

MIGHTY PRO 1/4 HP CHILLER

Miniature Thermoelectric Cooler Controller MTCC-01 user's guide

Edition 8, From serial no Publ. no OM 5030, Orwak 5030 OPERATING INSTRUCTIONS (IN THE ORIGINAL)

Operator's Manual. LIGHTNING 2 Laser Detector

DIE GRINDER INSTRUCTIONS IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY TO ENSURE THE SAFE AND EFFECTIVE USE OF THIS TOOL.

Adam Equipment. NCSA 20plus. (P.N Revision B - September 2012)

SILENT compact /

Virtu 60 and 80 series. Coffee machine

HR 601 C A AUS. ENGLISH Instructions for use Page 2

IMPORTANT SAFETY INFORMATION

Digital Heat Block User Manual

MD-MINI Dry Bath. Instruction Manual

IH 025 VOLCANO. Portable Induction Heater. smart mounting

Operating Instructions!

Original instructions JSNY7 Magnetic switch

FAN HEATER. Models: DEVIL OPERATING & MAINTENANCE INSTRUCTIONS

Installation instructions and operating manual. Sauna control system FCU1000 / FCU1200

HIGH VOLTAGE A.C. PROXIMITY DETECTOR HI-PROX

DOC JAN06 LT 200

MICRO-KJELDAHL EQUIPMENT ( MM SERIES ) OPERATING AND SAFETY INSTRUCTIONS

24 & 30 Drum Fan. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

Original instructions Sense7-series Non-contact coded safety switch

DXAPV3N. Air Purifier. With. Enviro-neutralising Technology DXAPV3N

Virtu 40 series. Coffee machine

Price Book 2015 Drum Pumps For Non-Corrosive Liquids

Digital 7 Square Plate Magnetic Stirrer

SWARCO TRAFFIC SYSTEMS GMBH. TDD1-MW Traffic Detector User Manual TDD1-MW_BE_00

Screw-in heater (EHK)

Operating Manual. English. Refrigerators for chemicals KRC 50 KRC 180

CIR Carbon Infrared Emitter. Operating instructions

RESISTENT PLUS D A CH Gebrauchsanleitung GB IRL AUS USA NZ CDN IND Instructions for Use... 12

10 & 12 Ventilator. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

+ English + 1. Safety warnings

FRESHAIR USER S MANUAL. CAUTION: Read manual carefully for proper procedures and operation.

Ceramic soleplate steam iron. Help line: Model: SI30110BLKN v1.0

600W Hand Blender. Model: SP20160 (all colours) Helpline: v1.0. SP20160_IM.indd 1 26/07/ :38

INSTRUCTIONS AND WARRANTY

Thermo Scientific Round Top Hotplate Stirrers. Make safety and accuracy part of your routine

Reacti-Therm I and III Heating Modules

HULME MARTIN HEAT SEALERS

Sip Vacuum Cleaner 1400/35 Wet & Dry

Operator s Manual. Mirage. Buffet Induction Warmers

USER S MANUAL ATH WH220

Instruction Booklet Please read these instructions carefully and retain for future reference

ICE MAKER. 26 Lbs. Capacity HME010019N. Before using your Ice Maker, please read this manual.

1.5L Fryer v1.0. Model: SD6060N. Helpline. SD6060N_IM.indd 1 07/10/ :58

RESISTENT EXTRA 3592, 3602 RESISTENT EXTRA PLUS 3592P, 3602P

MS-H-Pro-T Magnetic Hotplate-Stirrer with Timer

Hot Water Urns v3.0. all models. Helpline. instructions.indd 1 02/06/ :50

HULME MARTIN HEAT SEALERS

EN Instruction manual. gasprofi 1 SCS micro. The smallest laboratory gas burner with more safety. DIN 30665, part 1

Kettle v1.2. Models: SK (all models) Helpline:

Owner s. Coolerr. comply. To view

Steam Generator v2.0. Model: SI9021N. Helpline. SI9021N_IM.indd 1 28/10/ :45

Vintage Desk Fan. Model: SF1010 (all colours) Helpline. v1.1

Toaster. Model: ST17020/ST17010 (all colours) v1.0. Helpline:

Owner & Operator s Manual. Table of Contents

User instructions. VA20HD, VA55HD, VA55IND and VA75IND. Commercial wet/dry vacuum cleaners CAUTION - READ THESE INSTRUCTIONS BEFORE USING THE MACHINE

INSTRUCTIONS AND WARRANTY

FACTORY AUTOMATION. Instruction Manual NBB20-L2-E2B-C-V1 NBN40-L2-E2B-C-V1 Inductive Sensor

MANUAL Overflow sensor NVF-104/34-PF

IMPORTANT SAFETY INSTRUCTIONS

Service: to SLK Laboratory Hot Plates glass made of ideas

Warranty. Thanks. Thank you for purchasing the Oliso Smart Iron, a safer, smarter way to iron.

Compression Sprayers TECH DATA SHEET /03/17. Ersatzteile Spare Parts Pièces de Rechange

Coffee Machine Zia series

SCHMIDT LED Measured Value Display MD Instructions for Use

Studio Mug. Operators Handbook. Rev A - 24/08/ a.adkins and sons limited. all rights reserved

Instruction Manual Suppository Penetration Tester. Type PM 30

MaxLite Polygon Linear LED Light

Instruction Manual Mini Hotplate Mini Stirrer Mini Hotplate-Stirrer Mini Auto Stirrer Mini Fixed Temperature Hotplate

Because you re not like everyone else. EVAPORATIVE COOLER EC220W OWNER S MANUAL

Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode

Transcription:

Bühler Infrared Heater POWERCUBE IRB 1 POWERCUBE IRB 2 POWERCUBE IRB 6 These operating instructions are protected by copyright. Modifications reserved.

Contents: 1. General Notes 2. Description 2.1. IRB 1 2.2. IRB 2 2.3. IRB 6 3. Appropriate Use 4. Technical Data 4.1. IRB 1 4.2. IRB 2 4.3. IRB 6 5. Operation: 5.1. IRB 1 5.2. IRB 2 5.3. IRB 6 6. Safety Instructions 7. Special Features 8. Accessories 8.1. IRB 1 8.2. IRB 2 8.3. IRB 6 9. Maintenance 10. Technical Service Department 11. CE Declaration of Conformity 12. Warranty Edmund Bühler GmbH 2

1 General Notes You have chosen a Bühler high-quality product for supporting you in your work. All Bühler heaters were developed for the use in laboratories in a neutral environment. To ensure a long life and optimal operation of the device we recommend to observe the following points. Read the operating manual carefully before initial operation. The user must acquaint himself with the safety instructions and oerating conditions in order to avoid damage / injuries to material and personnel. Liability and all claims under warranty end immediately in case of damages which result from misuse and / or abuse. The devices were carefully checked for perfect functioning and condition before delivery. Necessary servicing or repair work may only be done by personnel of the manufacturer (Edmund Bühler GmbH), their authorized agents or personnel trained by Bühler. For shipping, the device must be adequately and safely packed. If possible, use the original packing. If the device is returned to Bühler for repair, it should be cleaned and free from any harmful substances or residues. Edmund Bühler GmbH 3

2 Description: 2.1 IRB 1 The infrared heater POWERCUBE 1 is a compact laboratory heater for contactless heating tasks in laboratories, factories and schools. It is especially well suited for hydrous solutions, which have a high absorbancy in the infrared range. They can be heated fast and efficiently. 2.2 IRB 2 Laboratory heater with integrated power control for fast heating of larger volumes. Thanks to its high safety standard it can be used in laboratories where traditional heaters with open flame cannot be employed. 2.3 IRB 6 Modular laboratory heater with 6 x IRB 1 in a housing with 6 power control units. Each heater can be individually used and controlled. 3 Appropriate Use: Large flat-bottomed heat resistant vessels (generally Duran glass, glass etc.) can be placed directly on the upper heat shield for heating up the filled-in liquid Small vessels or round-bottom vessels have to be mounted on a stand, in appropriate distance above the radiator. For special applications, the POWER CUBE itself can also be fixed in a stand by means of the support rod (see accessories). Edmund Bühler GmbH 4

4 Technical Data: 3.1 IRB 1 Max. temperature: 700 C Heating power: 200 W Heating area: 60 x 60 mm Max. ambient temperature: 30 C Electrical supply: 230 V or 115 V, 50 / 60 Hz Dimensions (w x d x h): 100 x 105 x 105 mm Weight: 0.7 kg 3.2 IRB 2 Max. temperature: 900 C Heating power: 800 W Heating area: 100 x 100 mm Power control: stepless control between 0 100% Max. ambient temperature: 30 C Electrical supply: 230 V, 50 / 60 Hz Dimensions (w x d x h): 150 x 150 x 170 mm Weight: 2.5 kg 3.3 IRB 6 Max. temperature: each 700 C Heating power: 6 x 200 W Heating area: 6 x 60 x 60 mm Power control: 6 stepless controls between 0 100% Max. ambient temperature: 30 C Electrical supply: 230 V, 50 / 60 Hz Dimensions (w x d x h): 697 x 305 x 122 mm Weight: 9 kg Edmund Bühler GmbH 5

IRB 2: (Heat is emitted upwards) Measuring sensor Heating power IRB 2 Power control at position 10, without vessel on the support cross Temperature measurement at the level of the support cross: Start: 20 C After 10 min: 520 C Max. Temp.: 520 C IRB 2: Cover / Beaker etc. Measuring sensor Heating power IRB 2 Power control at position 10, with vessel on the support cross Temperature measurement at the level of the support cross: Start: 20 C After 3 min: 800 C After 7 min: 900 C Edmund Bühler GmbH 6

5 Operation: 5.1 IRB 1 After connection to a 230 V or 115 V mains the system is ready for operation and can be switched on by actuating the rocker switch at the front. (The switch illuminates). 5.2 IRB 2 After connection to a 230 V mains the system is ready for operation and can be switched on by actuating the rocker switch at the back (LED at the front illuminates). The power can be steplessly adjusted with the rotary switch at the front between 60 W (position 1) and 800 W (position 10). 5.3 IRB 6 After connection to a 230 V mains the device is ready for operation and can be switched on by actuating the rocker switch (the switch illuminates). The power can be steplessly adjusted with the rotary switches. 6 Safety Instructions: Attention!!! The safety instructions must be followed!!! While the device is switched on, but also the first 15 minutes after the system has been switched off (cooling off), the upper part (infrared radiator and stainless steel sheets) may not be touched, nor be brought close to objects which can catch fire (paper, cloth, fabric, etc.). In a distance of approx. 1-2 cm from the ceramic radiator temperatures are reached that can inflame the above mentioned objects. Do not heat up objects or vessels in direct contact with the ceramic heating element. Use the support cross and place the vessel on the cross. Empty vessels with little distance to the ceramic heating element risk to break. The IRB 2 has an excess temperature protection. If the bottom of the housing reaches temperatures above 60 C, the system is switched off automatically. For safety reasons, the device should be switched off completely for some time. When it has cooled down, it can be heated up again as usual. Edmund Bühler GmbH 7

7 Special Features: The electronic parts are shielded against spilling liquids. Additional lateral safety shields for the heating element. Touch-proof housing during operation. Built-in handles for safe transportation even when the heater is hot. (IRB 2) 8 Accessories: 8.1 IRB 1 Power control LR 1: No. 6070 000 Support rod for stand connection (Ø 10 x 130 mm): No. 0012 164 8.2 IRB 2 Support rod for stand connection: (Ø 10 x 130 mm): No. 0012 164 8.3 IRB 6 Support base (length approx. 75 cm): No. 0052 060 Horizontal PVC rod for support base: No. 0052 091 Clamps for PVD rods (Nr. 0052 091): Ø D50 (NS45) with distance piece, e.g. for Soxleth: No. 0001 140 Ø D32 (NS29) with distance piece No. 0001 138 Ø D20 (NS19) with distance piece No. 0001 136 Ø D25 (NS15) with distance piece No. 0000 789 Edmund Bühler GmbH 8

9 Maintenance: The heaters, especially the infrared radiator, is maintenance-free. Appropriate use ensures extremely long life of the heating element (approx. 7000 h). 10 Technical Service Department: In case of failure, please contact the Technical Service Department of the Edmund Bühler GmbH. Edmund Bühler GmbH Technical Service Deparment Am Ettenbach 6 D-72379 Hechingen Tel.: +49 (0) 7471 / 9864-0 Fax: +49 (0) 7471 / 9864-75 E-Mail: info@edmund-buehler.de 11 CE Declaration of Conformity: We declare under our sole responsibility that this product corresponds to the EC directives 89/336EEC and 73/23EEC und The following harmonised standards apply: EN 61 010; VDE 700 part 1. 12 Warranty: The Edmund Bühler GmbH warrants that this device has the properties guaranteed by contract and that it does not have any defects which rescind its value or its use for customary and usual applications or applications foreseeen by the contract. (See General Terms and Conditions of the Edmund Bühler GmbH). The warranty period ends 24 months after delivery (date of invoice). The warranty does not include wear parts. Excluded from warranty are malfunctions caused by misuse or improper use, installation, or maintenance. Warranty ends immediately if the device is subjected to technical modifications which are not authorized in advance by Edmund Bühler GmbH Edmund Bühler GmbH 9