Improving Alarm Response in ICU/CCU

Similar documents
2011 National Clinical Alarms Survey: Perceptions, Issues, Improvements and Priorities

Impact Of Clinical Alarms On Patient Safety. American College of Clinical Engineering Healthcare Technology Foundation (AHTF)

Clinical Alarm Effectiveness: Recognizing & Mitigating Risk to Patient Care

You finally make it home after a long shift, shower,

Why Clinical Alarms are a TOP TEN Hazard

Alarm Fatigue in the ICU. Lynn Maguire MS, RN, PMC, NE-BC

Why Building Occupants Ignore Fire Alarms

Alarm Management. Objectives

Focus on Respiratory Care & Sleep Medicine Irvine, CA. Alarm Management. September 14-15, 2018

Original Article. Intra-operative monitoring many alarms with minor impact. Summary

Alarms That Deserve Attention. Mike Rayo 3/29/2016

Managing Clinical Alarms

Improving Alarm Management Utilizing Technology. NJ/DVHIMSS Annual Fall Event. Empowering the New Healthcare Era

A SURVEY OF OCCUPANT RESPONSE TOWARDS AN AUDIBLE FIRE ALARM

Alarm Management at Boston Medical Center A Roadmap to Safe Silence

Ensuring the Effectiveness of Clinical Alarm Systems

URGENT: MEDICAL DEVICE CORRECTION Plum 360 Infusion System List Number: 30010

Hospital Ward Alarm Fatigue Reduction Through Integrated Medical Device Instruction and Hospital System Policy

Reference Case: Avera Heart Hospital Data-Driven Approach Helps Hospital Build Effective Clinical Alarm Management Program

Safety Innovations FOUNDATIONHTSI. Cardiopulmonary Monitors And Clinically Significant Events in Critically Ill Children

Clinical Alarm Management Strategies Meaningful Alerts

False Alarm Suppression in Early Prediction of Cardiac Arrhythmia

Running head: REDUCING THE HARM ASSOCIATED WITH CLINICAL ALARMS 1

ABB Ability System 800xA Alarm Management

DESIGN FOR ELDERLY EGRESS IN FIRE SITUATIONS

Interim Advice Note 76 / 06 ASSESSMENT PART 1 AIMS AND OBJECTIVES OF ENVIRONMENTAL ASSESSMENT. Contents

BUSINESS PLAN CEN/TC 215 RESPIRATORY AND ANAESTHETIC EQUIPMENT EXECUTIVE SUMMARY

RESEARCH ON THE MAIN CRITERIA OF DECISION-MAKING FACTORS THAT AFFECT CONSUMERS' PURCHASE OF RESIDENTIAL FIRE ALARMS

Kendall DL Cable and Lead Wire System. Your Disposable ECG Cable and Lead Wire Safety Solution. Safe, Simple, Secure

Received: 26 th Feb-2014 Revised: 29 th March-2014 Accepted: 30 th March-2014 Research article

2013 Compliance Report RCW 52.33

An Integrative Review

The Complexity of Clinical Alarm Systems

SIL DETERMINATION AND PROBLEMS WITH THE APPLICATION OF LOPA

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

ELECTRICAL SAFETY IN HEALTHCARE FACITILIES

Scholars Research Library. The Role of Plant Clinic in Protecting Vertical Urban Green Spaces in Tehran

International Journal of Advancements in Research & Technology, Volume 2, Issue 8, August ISSN

A Novel Approach to Cardiac Alarm Management on Telemetry Units. Medical Device Alarm Safety in Hospitals Joint Commission Webinar May 1, 2013

Safety Innovations FOUNDATIONHTSI. Using Data to Drive Alarm System Improvement Efforts. The Johns Hopkins Hospital Experience

AST Guidelines for Best Practices in Alarm Management in the Operating Room

ADIPEC 2013 Technical Conference Manuscript

Battery Performance Alert: A TOOL FOR IMPROVED PATIENT MANAGEMENT FOR DEVICES UNDER BATTERY ADVISORY

Monitoring Natural Air Corn Drying A Demonstration Project

Focused Evaluation of Rainwater Harvesting: A Case Study in Sandakan, Sabah, Malaysia

AUDIBLE ALARMS AND WORKPLACE NOISE IN NURSING UNITS: AN ENVIRONMENTAL FACTORS CASE STUDY

Digiplex LED Keypads User s Manual

FFT Functional Family Therapy Evidence Based. Cost Effective. Sustainable. Family, Youth & Culture Sensitive.

Effective Alarm Management for Dynamic and Vessel Control Systems

Contents of ANSI/AAMI HE75:2009 Page

Auditory Alarm Signals

The Joint Commission's National Patient Safety Goal on Alarm Management: How Do We Get Started?

Medical devices and electromagnetic compatibility. Addressing the requirements of IEC , 4 th Edition

The Contra Costa EMS System and Fire Station Closures: Impact and Mitigation

EasyChair Preprint. Measuring Alarm System Quality in ICUs (WIP)

PERFORMANCE METRICS FOR SAFE LASER OPERATIONS AT SLAC NATIONAL ACCELERATOR LABORATORY 1 Paper # 203

ISO/TR TECHNICAL REPORT. Fire-safety engineering Technical information on methods for evaluating behaviour and movement of people

CHAPTER I: INTRODUCTION

GARDEN AS RESTORATIVE ENVIRONMENT FOR CHILDREN IN MALAYSIAN HOSPITAL SETTING

This document is a preview generated by EVS

ISO/TS TECHNICAL SPECIFICATION. Medical devices Hierarchical coding structure for adverse events Part 1: Event-type codes

Battery Performance Alert

2.1 CO is a colorless, odorless, tasteless, non-irritating, toxic gas.

Fact File 75. Published Document PD CEN/TS 54-32:2015 Fire detection and fire alarm systems

Austin Independent School District Police Department Policy and Procedure Manual

Functional Versus Schematic Overview Displays: Impact on Operator Situation Awareness in Process Monitoring

THE APPLICATION OF THE COMMON DESIGN RECOMMENDATIONS (CDR) IN ASSESSING RESTORATIVE GREEN OUTDOOR ENVIRONMENTS

How long do smoke alarms function? A cross-sectional follow-up survey of a smoke alarm installation programme

Alarm Safety in 2017:

Preventing ECMO Patient Harm While Using Remote Monitoring: A Case Report. Emily Thunstrom

Assessment of the Probabilities that Staff and/or Patients Will Detect Fires in Hospitals

Community Service-Learning Program Evaluation Report for

Abstract. Introduction

The new Gas Appliances Regulation (EU) 2016/426

Proulx, G.; Richardson, J.K. NRCC-45663

Fire Safety Report & Audit

Alarm Management for SCADA control rooms

IFE Level 4 Certificate in Fire Science and Fire Safety

CARBON MONOXIDE (CO)

Estimating the Level of Free Riders in the Refrigerator Buy-Back Program

An Approach to Model Checking the Perceptual Interactions of Medical Alarms

The Development of Fire Risk Assessment Method for Heritage Building

Bernoulli Smart Alarms & Surveillance: Applying Analytics in Real-Time

The Urban Park Soundscape in Mountainous Cities:A case study in Chongqing

GE Healthcare. Dash Variable-Acuity Monitoring

COMMUNITY GROWN FOOD IN WALES

Capnostream 20p Bedside Capnography Monitor. The only integrated, complete picture of oxygenation and ventilation 1

Research on Decision Tree Application in Data of Fire Alarm Receipt and Disposal

ECOLOGICAL GOVERNANCE

"It's Alarming Simple Steps To Reduce Nuisance Alarms

How to Use Fire Risk Assessment Tools to Evaluate Performance Based Designs

Alarm Management Standards Are You Taking Them Seriously?

Blood Alley Square/Trounce Alley Redesign

HEALING GARDENS IN ITALIAN ARCHITECTURES FOR HEALTH. A quali-quantitative approach to evaluate existing green areas in hospitals

Nestlé Brazil Independent assurance of compliance with the World Health Organisation (WHO) International Code of Marketing of Breast Milk Substitutes

Video Analytics Technology for Disaster Management and Security Solutions

Technical Paper. Functional Safety Update IEC Edition 2 Standards Update

FIRE SAFETY POLICY. Version: 4 Senior Managers Operational Group Date ratified: March 2016

INTERNATIONAL STANDARD

VASHON-MAURY FIRE AND RESCUE Community Needs Survey Executive Summary March 2000

Transcription:

Improving Alarm Response in ICU/CCU Sasikala Thangavelu Faculty of Science and Technology Plymouth University Plymouth,England sasikala@mdb.gov.my Emmanuel Ifeachor Faculty of Science and Technology Plymouth University Plymouth,England e.ifeachor@plymouth.ac.uk Jasmy Yunus Faculty of Biosciences and Medical Engineering Universiti Teknologi Malaysia Johor Baru, Malaysia jasmy_yunus@yahoo.co.uk Judy Edworthy Faculty of Health & Human Sciences Plymouth University, Plymouth, England J.Edworthy@plymouth.ac.uk Abstract Clinical alarm plays a critical role to alert clinician to situations that require urgent response. However, alarms are often ignored or switched off. The objectives of the study are to identify how clinicians responded to user response, propose response time and recommend improvements to the clinical alarm performance. A focus group was commissioned to identify the high and medium risk based alarm conditions and propose appropriate response time. A survey was carried out in Malaysia with 324 clinicians, 279(86.1%) were registered nurses and medical assistants (MA) and 45(13.9%) were medical doctors. The findings show that 16.0% of the respondents switched off the alarm, 20.4% silenced the alarm, 14.5% delayed to respond and 20% ignored the alarm. The findings indicate 78.1% of the respondent recommended less than 10sec for immediate respond for high risk alarm, 72.5% recommended less than 60sec for prompt respond for medium risk alarms but49% recommended that delayed respond for low risk alarm should not be specified. This will then reduce the number of alarms and workload in ICU/CCU. The key recommendation that has been proposed to improve clinical alarm performance is to ensure the alarm signal to indicate urgency to respond. The incorporation of the response time based on risk in the design of alarm, to indicate urgency to respond in auditory alarm signal can improve user response and patient safety. Keywords- Clinical alarm system, alarm response, patient safety I. INTRODUCTION With the advancement of healthcare technology, almost all medical devices in intensive care and critical care units (ICU/CCU) are incorporated with clinical alarms. Clinical alarms play a critical role as a monitoring device to assist and alert clinician to situations that require urgent response especially in ICU [1]. Immediate response to alarm is crucial as it indicates potentially life threatening complication and any delayed response leads to compromising of patient safety with potentially serious adverse consequence [2]. Numerous studies on clinical alarm systems indicate dissatisfaction among the clinicians with the clinical alarm systems [3][4][5][7][8]. These studies indicate that problems associated with clinical alarm system include too many alarms, confusing alarms, difficulty in identifying the source of an audible alarm, unnecessarily loud and distracting alarms, difficult to differentiate criticality amongst alarms and high incidence of false alarm conditions. Edworthy et al. and Hass et al. identified the five critical problems with auditory alarms in ICU and Operation Room (OR), which are acoustic similarity of alarms, too many alarms, irritating alarms, inappropriately risk mapped alarms and false alarms [10][5]. These problems are further aggravated with no standardisation in clinical alarm design, alarm signals which do not relate to patient conditions and alarm signal which do not indicate urgency [11]. These problems have led to loss of confidence among the clinicians in the alarm systems causing poor user response, alarm fatigue, ignoring and switching off the alarm [12]. Cvach in her review further highlighted that the problem of alarm desensitization is also related to high false alarm rate, poor positive predictive value and too many medical devices in hospitals today [34]. Cvach et al. also reported in another study that alarm fatigue causes nurses to desensitize alarm signals which presents potential harm to patient safety [17]. Alarm fatigue has been defined as the desensitization of a clinician to an alarm stimulus that results from sensory overload causing the response of an alarm to be delayed or missed [9].Tanner in his article reinforced this problem by relating alarm fatigue in nurses likewise becoming anesthetized to alarm sounds as a result of excessive auditory exposure resulting in slower response time of a clinician [10]. Further, Keller and Logan indicated that alarm fatigue occurs when caregivers become overwhelmed with the large number of clinical alarms such that critical or significant events can be missed or ignored [12][13]. Whereas Wikllund and Kendler identified that 1.1

clinicians may ignore alarms because of frequent occurrence of false auditory alarm limiting the value of the information emitted to a caregiver in a clinical situation leading to alarm fatigue [14]. These issues of failure to respond are major concern especially in ICU/CCU where the problem of not responding or delayed response can prove to be fatal to patients. This paper presents the outcome of the focus group discussion on the user response in ICU/CCU. Further surveys were conducted among the ICU/CCU clinicians to study the user response, propose response time and recommendations to improve user response. A. User environment User environments such as ICU/CCU can have major impacts on device use and use-related hazards such as alarm hazard. The environment in ICU/CCU causes mental workload on users to exceed their abilities to respond effectively and timely to alarms. There is physical workload associated with medical device that adds to the stress experienced by the user. Under high stress levels in ICU/CCU, the clinicians will be distracted and will have less time to make decisions. The ICU/CCU environments can limit the effectiveness of visual and auditory displays which will lead to clinicians being unable to understand critically important information on the use of the device. This error could lead to difficulty to notice alarms if they are not sufficiently loud or distinctive or the user fails to notice alarms or to make important distinctions among different alarm sources. R. D. Patterson et al. highlighted that in ICU/CCU, the patient safety is crucial but when workload is high, the alarm signals can become a distraction or a nuisance [15]. In this high workload and high pressure situations, sensitivity to human factor increases affecting the cognitive and perceptual ability of the users [15]. Burt et al. showed that perception of urgency of alarms is greatly impaired under high workload [16]. A. Guillaume et al. further highlighted that acoustical properties are less effective in stimulating perceived urgency under high workload such as ICU/CCU[19]. These increase the risk of user errors or incidents which could lead to serious complication or fatality [2][19]. Poor performance of the alarm system will result in poor patient care and patient not receiving appropriate care, which may also result in missing true alarms [3][18]. All these problems lead toward nonperformance of the alarm system and compromises patient safety with potentially serious adverse consequence [2]. B. Alarms and adverse events The MAUDE database in United States houses medical device reports submitted to the Food Drug Agency (FDA)by mandatory reporters such as manufacturers, importers and device user facilities and voluntary reporters such as health care professionals, patients and consumers [35]. The alarm system based on adverse events reported in the FDA- MAUDE database were reviewed over the period of 2002-2004 with search term alarm and the event death and it reported 237 incidents [36]. This was further reviewed in a report by American College of Clinical Engineering (ACCE) Healthcare Technology Foundation which indicated that 52.8% of the incidents were due to operator or users [37]. In 2004, this number increased to 449 according to US FDA s Maude database [36]. From 2005 through 2008, FDA received 566 reports of patient deaths related to the alarms on monitoring devices. Recent reports from MAUDE from 1/12/2004 to 31/12/2014 indicate a total of 50 deaths and 844 injuries were reported due to alarm system [36]. From these adverse event reports it can be concluded that users are one of the main cause of these alarm incidents. As such it is timely to identify the alarm problems associated with user response, rectify and propose means to improve effectiveness of the alarm performance in ICU/CCU. This improvement in user response should take into account human factor consideration, the psychophysical tools and mental representation of the response sequence in alarm design [38]. C. Objective The objectives of the study are to identify how clinicians responded to alarms, propose response time and recommend improvements to the clinical alarm performance D. Scope This study was limited to clinicians working in ICU/CCU in public and private hospitals in Malaysia. The participants were doctors, nurses and medical assistants (MA). II. A. Focus Group METHODOLOGY OF STUDY A focus group is a group of individuals selected and assembled by researchers to discuss and comment on, from personal experience, the topic that is the subject of the research [39]. Focus groups can be used at the preliminary or exploratory stages of a study, during a study, perhaps to evaluate or develop a particular programme of activities or after a programme has been completed, to assess its impact or to generate further avenues of research [40][41][42]. In this research, the focus group was selected among the ICU/CCU clinicians comprising of consultants, specialist, doctors, tutors and senior nurses to deliberate on the challenges of clinical alarm system in ICU/CCU. The discussion was designed to gather information from the respondents regarding the following outcomes: i) the respondent s reaction or responses when an alarm triggers in ICU/CCU ii) the response time to represent the immediate, or prompt and delayed response based on IEC IEC 60601-1-8:2006 recommendations [20]. 1.2

These levels of urgency were graded to indicate different situations such as less urgent for delayed response time, urgent for prompt response time and critical for immediate response time. For high risk patient conditions, the following conditions were discussed in the focus group to identify response time: Asystole Ventricular fibrillation Failure of a cardiac support device (intra-aortic balloon pump, cardiopulmonary bypass machine) Sustained high airway pressure Extreme hypoxemia The medium risk physiological conditions that requires prompt response: Cardiac arrhythmias associated with hypotension Low blood pressure, Hypotension Apnea (unless prolonged or associated with extreme hypoxia) Mild hypoxemia Failure of an infusion pump for maintenance of vasopressor agents iii) list of improvement needed in a physiological patient monitor. B. Survey The survey was conducted throughout Malaysia and the questionnaires were distributed to public and private hospitals. A total of 10 hospitals participated in this survey. It was conducted among clinical staff in the ICU. This survey was conducted to study the perception and response of the clinical staff towards the alarm system. The survey was to undertake a comparative study of responses of two groups of users or clinicians, group 1 consists of doctors and group 2 consists of nurses and medical assistants (MA). The objectives of the survey are to identify how clinicians responded to clinical alarm, recommendation to alarm response time for physiological conditions that needed immediate, prompt and delayed response and user recommendations to improve alarm system design for physiological patient monitor. A questionnaire was developed for the purpose of this survey based on the outcome of the focus group discussion. There were four sections in the questionnaire, focusing on obtaining information regarding the clinical alarm systems and the associated problems in the ICU/CCU. The questionnaire is attached in Annex 1. The first part, Part A, requested demographic information from the respondents as to the length of services in ICU/ CCU, designation and were categorised into age groups below 25, 25 to 35, 35 to 45 and above 45.Part B of the survey was to identify how frequently the respondents reacted or responded when an alarm triggers in ICU/CCU. Part C on preferred response time for immediate, prompt and delayed response as specified in IEC60601-1-8:2006 [20]. In the questionnaire, three sets of response time had been proposed for immediate response that are, less than 10seconds,10-20seconds and less than 30seconds whereas for prompt response, less than 1minute,1-5minutes and less than 15minutes. Further the improvements proposed by the focus group were listed in the questionnaire for the respondents to identify the key areas of improvement needed in a physiological patient monitor. Mann-Whitney test was carried out using IBM SPSS STATISTICS 21. Z- tests and charts were created using Microsoft Excel 2007. A. Focus Group Findings III. RESULTS A total of 9 clinicians working in the ICU/CCU participated in the focus group(fg) discussion, one consultant, one specialist, 2 doctors, three senior nurses and a nursing tutors Outcome 1: The respondent s reaction or response when an alarm triggers in ICU/CCU. In general, the respondentsagreed that clinical alarms monitors and alerts clinician to situations and conditions that have exceeded normal physiological limit. They stressed that in ICU/CCU the alarms play an extremely important role as a life saving device to monitor the physiological condition of critically ill patient that require urgent response. They indicated that there were numerous problems associated with clinical alarm system such as too many alarms, confusing alarms, difficulty in identifying the source of an audible alarm, unnecessarily loud and distracting alarms, difficult to differentiate criticality amongst alarms and high incidence of false alarm conditions. The clinicians agreed that they responded immediately to alarm signal most of the time however they too delayed the response, ignored, switched off and silenced the alarms. Outcome 2: The response time to represent the immediate, or prompt and delayed response based on IEC 60601-1-8:2006 recommendations [20]. The FG agreed that immediate response to alarm is crucial. Any delay in responding could lead to death and potentially life threatening complication. Therefore delayed response compromises patient safety with potentially serious adverse consequence. However the FG also indicated that alarm signal should be based on the risk associated to the patient s physiological condition. The alarm signal should not only alert the clinicians but also need to inform them the conditions of the patient. The information with regards to response time for these physiological conditions which triggered the alarm need to be embedded in the signal. As such they 1.3

recommended that the response time be categorized based on risk in line with the IEC 60601-1-8:2006 recommendations. The response time graded to represent levels of urgency, Immediate, Prompt and Delayed. Immediate response time is required for problems that cause patient injury or death within seconds to several minutes if uncorrected or critical situation. The Prompt response time is required for problems that do not cause patient injury or death until at least several minutes have elapsed. Delayed response time is required for problems that cause patient injury only after many minutes to hours have passed [20]. This group proposed three response times for immediate that are less than 10seconds,10-20seconds and less than 30seconds for high risk physiological incident. Whereas for prompt response, the FG proposed response less than 1 minute, l1-5minutes and less than 15minutes. The FG proposed that alarms should only be triggered for high and medium risk incidents to reduce the number of alarms which invariably reduce alarm fatigue in ICU/CCU. Outcome 3: list of improvement needed in a physiological patient monitor The FG recommended the following improvements to physiological patient monitor: Alarm sound indicates urgency to respond to critical alarm; Audio sound to indicate severity of the patient condition Medium(M) and High(H) Risk; Alarms sound designed based on human factor; Integrate action plan with each alarm condition Hand M; Interactive and guided alarm system to set limit based on physiological condition of patient; Alarm sound level: automatically adjust to the surrounding sound level; Different manufacture of same device to have similar alarm sounds; Visual light indicator to indicate that the device has problem(faulty) until rectified (no reset allowed); When there are more than 2 conditions, the highest risk condition monitored by patient monitor to trigger alarm sound; Biometric of user (clinician) to activate or deactivate alarm or make any changes in alarm limit setting; and Integrate all alarm attached to patient, one patient one audio alarm B. Survey Findings A total of 324 respondents, 45 doctors and 279 nurses/mas participated in this survey. Table1 presents the demographic profile of the respondents. The respondents comprised of 279(86%) nurses and 45 (14%) doctors. Almost half (52.0%) of the nurses were 25 to 35 years old and only 12 (4.4%) were above 45 years old. Similarly, majority (68.9%) of doctors were 25 to 35 years old and only 4 (8.8%) were more than 45 years old. In Section B of the survey, we investigatedproblems associated with alarm system in ICU/CCU. The respondent needed to tick one of the options below: 1= Strongly Disagree 2= Disagree 3= Agree 4=Strongly agree The responses were then recoded as 1 (Agree or Strongly Agree) if the value chosen is 3 or 4 and 0 (Strongly Disagree or Disagree) if the number chosen is 1 or 2. The z-test for two proportions was used to test if there is any significant difference in the proportions of doctors and proportion of nurses who agree or strongly agree regarding problems associated with the alarm system. Results summarised in Table 2 shows that a high proportion of nurses agreed that there are too many alarms (72%) and similar device from different brand or model do not have similar alarm sounds (73%). Meanwhile, 65% of doctors agreed that similar device from different brand or model do not have similar alarm sounds as the main problem associated with alarm system in ICU/CCU. There are significant differences of agreement for items Too many alarms, Alarms are too loud, Alarms not audible and Alarms are nuisance in ICU/CCU (B1, B2, B3 and B5) with a higher proportion of nurses who agreed on these four issues. In Section D, we investigated user response when an alarm is triggered in ICU/CCU. The respondent needed to tick one of the options below: 1= None 2= Sometimes 3= Most of the time 4=All the time The responses were then recoded as 1 (Most or all the time) if the value chosen is 3 or 4 and 0 (None or sometimes) if the number chosen is 1 or 2. The z-test for two proportions was again used to test if there is any significant difference in the proportions of doctors and proportion of nurses who responded most or all the time when an alarm is triggered. The results are summarized in Table3 which shows how the clinicians reacted or responded when an alarm is triggered in ICU/CCU. A total of 91% of the respondents agreed that they responded immediately when an alarm was triggered. The findings indicate 17% of the respondent switched off the alarm, higher percentage of nurses (18%) to doctors (9%) switched off the alarm. The findings indicate 21% of the respondent silenced the audio of the alarm. It also indicates higher percentage of nurses (22%) compared to doctors (16%) silenced the audio of the alarm. A total of 6% of the respondents agreed that they failed to respond when an alarm was triggered. Among the respondents, 7% of the nurses and 4% of the doctors agreed that they ignored (failed to respond) when an alarm was triggered. There is no 1.4

significant difference in alarm response between doctors and nurses. In Section E, we investigate recommendations for alarm response time. The respondent needed to tick one of the options below: 1= Strongly Disagree 2= Disagree 3= Agree 4= Strongly agree The responses were then recoded as 1 (Agree or Strongly Agree) if the value chosen is 3 or 4 and 0 (Strongly Disagree or Disagree) if the number chosen is 1 or 2. The z-test for two proportions was used to test if there is any significant difference in the proportions of doctors and proportion of nurses who agree or strongly agree regarding recommendations for alarm system response time. The results are summarized in Table 4. As shown in Table 4, 81% of the respondents recommended alarm response time for immediate response (high risk conditions) should be less than 10 sec. A total of 81% of the respondents recommended alarm response time for prompt response (medium risk conditions) should be less than 1min (60sec). A total of 49% of the respondents recommended that delayed response time for low risk incidents should not be specified. In Section F, we investigated with regards to recommendations to improve alarm system design for the physiological patient monitor. The respondent needed to tick one of the options below: 1= Strongly Disagree 2= Disagree 3= Agree 4=Strongly agree The responses were then recoded as 1 (Agree or Strongly Agree) if the value chosen is 3 or 4 and 0 (Strongly Disagree or Disagree) if the number chosen is 1 or 2. The z-test for two proportions was used to test if there is any significant difference in the proportions of doctors and proportion of nurses who agree or strongly agree regarding recommendations to improve alarm system design for the physiological patient monitor.the summary of the user recommendations to improve alarm system design for physiological patient monitor are provided in Table 5. It is noted that 92.0% of the respondents recommended that alarm sound should indicate urgency to respond to the critical alarm. Both the respondents, 91.0% of the nurses/ma and 97.8% of the doctors agreed strongly that the alarm sound should indicate urgency to respond to the critical alarm. It is to be noted that 86.7% of the respondents recommended an interactive and guided alarm system to set limits based on physiological condition of patient. Whereas 86.1% recommended three (3) types of alarm sounds: low (L), medium (M) and high (H) risk in the physiological patient monitor. It is to be noted that 82.1% of the respondents recommended that the alarms sound should be designed based on human factors. IV. DISCUSSION A clinical alarm system assists clinicians as a surveillance tool and enhances performance to monitor, warn and alert them of changes in the physiological condition of the patient. The focus group findings indicated that the clinicians are aware of the intended use of the alarm system to enhance patient safety and the key roles in monitoring critically ill patient in ICU/CCU. As such, most of the time the clinician responded immediately to alarm signals. However, the findings also indicated that the clinicians too delayed to respond to alarms, ignored, switched off and silenced the alarm signal. This issue of failure to respond needs to be considered seriously and the main reasons need to be identified and addressed. In critical areas such as the ICU/CCU, the problem of clinicians not responding to the alarm system could prove fatal to the patient. The focus group had raised concerns on these issues and identified that too many alarm problems has led to alarm fatigue and lack of confidence in the alarm systems amongst the clinician. The focus group had raised dissatisfaction on clinical alarm systems and issues of too many alarm problems which had been raised in numerous studies with the clinical alarm systems [3][4][5][7][8]. J McIntyre et al. had also indicated that these problems had led to lack of confidence in the alarm systems and the clinician to disarm, ignore or refuse to use alarms [26].National survey conducted by the Healthcare Technology Foundation (HTF) on clinical alarm issues also indicated the problems of alarm system which cause users to ignore alarms [37].To overcome these problems, especially on user response, it is proposed in this research that the alarm signals are designed based on risk and this information be embedded in the alarm sounds. This is to ensure the alarm signals can be easily identified and differentiated according to the risks of the patient s physiological condition. Patterson et al. graded this risk into three levels low, medium and high to ensure alarms are responded in a timely manner [27]. Whereas Edworthy et al. who investigated the impact of urgency on alarm response and indicated that urgency mapping increases the information of the level of priority, situation and response time in the alarm system [29][40]. This study further explores into urgency mapping by identifying appropriate response time to map this urgency to respond in the alarm signal. This focus group proposed to adopt graded response time to represent three levels of urgency as recommended by the international standard, IEC 60601-1-8:2006 and Patterson et al. However, the focus group proposed that alarms should only be triggered for high and medium risk incidents to reduce the number of alarms and alarm fatigue in ICU/CCU. The focus group also explored improvements to alarm problem concerning user response associated to physiological patient monitor. The recommendations are as follows: 1.5

Alarm sound indicates urgency to response to critical alarm Audio sound to indicate severity of the patient condition Medium (M) and High (H) Risk Alarms sound designed based on human factor Interactive and guided alarm system to set limit based on physiological condition of patient. These recommendations indicated that the alarm system need to be designed based on human factor engineering principles to address human limitations by providing relevant and timely information to users. These proposed response time by the FG were used in the survey to investigate the acceptance among the clinicians in the healthcare institution in Malaysia. The survey findings indicated that clinicians react and respond differently to different types of alarm. Their responses to alarm signal also included immediate response, delayed response, switch off, silenced the alarm and ignore the alarm signal. Similar responses towards alarm signal also indicated that the respondents of the survey perceived the present clinical alarm system to have too many alarm problems, unreliable and lack confidence in the alarm system. Block et al. in their study indicated that when alarm systems are unreliable, they tend to be ignored [21]. In this survey, a total of 17% of the respondent switched off the alarm, higher percentage of nurses (18%) to doctors (9%) switched off the alarm. The findings indicated 14.5% of the respondent delayed the respond to alarm signal. Whereas 21% of the respondent silenced the audio of the alarm. It also indicates higher percentage of nurses (22%) compared to doctors (16%) silenced the audio of the alarm. A total of 6% of the respondents agreed that they ignored the alarm. Among the respondents, 7% of the nurses or MA and 4% of the doctors have agreed that they ignored (failed to respond) when an alarm was triggered. These findings indicate that there is no significant difference between the doctors and nurse/ma response to alarm signal. This delayed or no response compromises patient safety with critical conditions undetected and leads towards occurrence of adverse events [41]. In addressing this shortcomings of the alarm system as to when to respond, information on urgency to respond based on risk of the patient s physiological condition needed to be embedded in the alarm signal. In this survey, the respondents were requested to identify the preferred alarm response time for immediate, prompt and delayed respond. A total of 81% of the respondents agreed that the recommended alarm respond time for immediate response (high risk conditions) should be less than 10 seconds. Whereas a total of 81% of the respondents agreed that the recommended alarm respond time for prompt response (medium risk conditions) should be less than 1min (60sec). Only a total of 49 % of the respondents agreed that delayed respond time for low risk incidents should not be specified as proposed by the focus group. Though FG do not want the low risk to trigger alarm in ICU but 51% of the respondent in the survey thinks otherwise. Since the FG recommended that the low risk alarm conditions should not trigger alarm and 49% of the respondents concur with them, therefore it is proposed as a compromise that only visual alarm and not auditory alarm to be triggered for low risk conditions. In the above premises, it is proposed that the response time which indicates the urgency to respond can be embedded in the alarm signal. These proposed times will guide the clinicians to respond accordingly. The concept of urgency mapping was introduced by Edworthy et al. to improve the response of the users [28][29]. Urgency mapping is defined as matching between the perceived urgency of the warning and urgency of alarm conditions [42]. In another study, E. Hellier et al. proposed that urgency mapping be embedded in the alarm design [30]. Early studies by Edworthy et al. showed that urgency of auditory alarms can be achieved by changing the acoustic parameters of the auditory signals [33]. Hellier et al. further detailed the relationship between objective parameters and subjective parameters that can be incorporated in the design of auditory warnings to facilitate urgency mapping [32]. Urgency mapping allows warnings to be mapped to situations that trigger appropriate user response. Further the perceived urgency in alarm system designs can be ranked to indicate the level of urgency associated with different alarms [32]. The level of urgency can be mapped to specific alarm sound [32]. Using psychophysics principles, Edworthy et al. and Hellier et al. defined that the acoustic properties induced different degrees of urgency perception [42]. Under high workload such as ICU/CCU, mental representation and psychophysical tools should also be taken into consideration in alarm design [19]. To further improve this concept, the proposed response time of the survey findings can be embedded in the alarm signal to indicate the actual respond time, visually or through audio representation. This will improve the alarm response accordingly. In line with these previous studies, the findings in Table V indicate 92.0% of the respondents recommended for physiological monitor that alarm sound should indicate urgency to respond to the critical alarm. These findings also indicated that there are no significant difference between the doctors and nurse/ma recommendations to improve alarm response. V. CONCLUSION From the findings of this study, it can be concluded that the various alarm responses of the clinicians are immediate response, delayed response and no response that is by switching off, silencing and also by ignoring the alarm. Further it can be established that by adopting not to respond to low risk alarm conditions, the number of alarm and workload in ICU/CCU can be reduced significantly thereby reducing the chances of occurrence of alarm fatigue among the clinicians. The key recommendation that has 1.6

TABLE I: DEMOGRAPHY OF RESPONDENTS Variable Gender Position Doctor/ Nurse/MA Male 21 (46.7%) 25 (9.4%) Female 24 (53.3%) 240 (90.6%) Position Age 1 below 25 2 25-35 3 36-45 4 Above 45 Nurses 66 (24.2%) 142 (52.0%) 53 (19.4%) 12 (4.4%) Doctors - 31 (68.9%) 10 (22.2%) 4 (8.8%) TABLE II: PROBLEMS ASSOCIATED WITH ALARM SYSTEM IN ICU/CCU Overall Doctors Nurses Item f % x1 n1 p 1 (%) x2 n2 p 2 (%) z p-value B1 211 66 11 44 25 200 278 72-6.088 0.0000 B2 155 48 11 44 25 144 278 52-3.306 0.0009 B3 72 23 4 45 9 68 270 25-2.410 0.0159 B4 135 42 22 45 49 113 276 41 1.001 0.3167 B5 106 34 7 44 16 99 270 37-2.700 0.0069 B6 229 72 28 43 65 201 275 73-1.083 0.2787 B7 177 57 21 44 48 156 267 58-1.328 0.1842 B8 163 52 17 44 39 146 267 55-1.975 0.0483 Items Description B1 Too many alarms. B2 Alarms are too loud. B3 Alarms not audible. B4 Alarms sound are annoying B5 Alarms are nuisance in ICU/CCU B6 Similar device from different brand or model do not have similar alarm sounds B7 False positive alarms are rampant/frequent. (False positive: A result that indicates that a given condition is present when it is not) B8 False negative alarms are rampant/frequent. (False negative: a result that appears negative when it shoud not). Notes: f=overall number of responses for 3 (Agree) and 4 (Strongly Agree) TABLE III: AGREEMENT ON HOW USERS REACT OR RESPOND WHEN ALARM IS TRIGGERED Question Doctors Nurses & MAs Overall (n=45) (n=279) (n=324) P value Immediate 41 (91.1%) 245 (87.8%) 286 (88.3%) 0.524 Delayed 4 (8.9%) 43 (15.4%) 47 (14.5%) 0.249 Switch off alarm 4 (8.9%) 48 (17.2%) 52 (16.0%) 0.158 Silence the audio alarm 7 (15.6%) 59 (21.1%) 66 (20.4%) 0.387 Ignore the alarm 2 (4.4%) 18 (6.5%) 20 (6.2%) 0.604 TABLE IV: AGREEMENT TO THE RECOMMENDED ALARM SIGNAL RESPONSE TIME Overall Doctors Nurses Response/Time (sec) f % x1 n1 p1 x2 n2 p2 z p-value Immediate <10 253 81 39 44 0.89 214 267 0.80 1.3391 0.1805 10-20 131 57 19 34 0.56 112 196 0.57-0.1370 0.8910 <30 68 30 7 35 0.20 61 190 0.32-1.4331 0.1518 Prompt <60 235 81 38 41 0.93 197 248 0.79 2.0159 0.0438* 60-300 144 62 20 32 0.63 124 202 0.61 0.1203 0.9042 <900 55 25 2 31 0.60 53 188 0.28-2.5860 0.0097** Delayed 140 49 16 35 0.46 124 250 0.50-0.4307 0.6667 *p<0.05; **p<0.01; f=frequency 1.7

TABLE V: RECOMMENDATIONS TO IMPROVE ALARM SYSTEM DESIGN FOR PHYSIOLOGICAL PATIENT MONITOR Question Overall Doctor Nurses/MA z P Alarm sound level: automatically adjust to the surrounding sound level 260 83 32 45 71 228-2.378 0.0174 Audio sound to indicate severity of the patient condition Low(L),Medium(M) and High(H) Risk 278 88 41 45 91 237 0.699 0.4849 Three(3) types of alarm sounds: L,M and H 279 88 40 44 91 239 0.582 0.5605 Alarm sound indicates urgency to response to critical alarm 298 94 44 45 98 254 1.086 0.2776 Alarms sound designed based on human factor 266 86 38 45 84 228-0.344 0.7310 Different manufacture of same device to have similar alarm sounds 237 76 41 45 91 196 2.539 0.0111 Visual light indicator to indicate that the device has problem(faulty) until rectified ( no reset allowed) 273 88 43 45 96 230 1.766 0.0773 When there are more than 2 conditions,the highest risk condition monitored by patient monitor to triggers alarm sound Biometric of user(clinician) to activate or deactivate alarm or make any changes in alarm limit setting Interactive and guided alarm system to set limit based on physiological condition of patient 277 89 40 44 91 237 0.422 0.6727 262 84 42 45 93 220 1.810 0.0704 281 90 42 45 93 239 0.732 0.4641 Integrate all alarm attached to patient, one patient one audio alarm 224 72 28 45 62 196-1.626 0.1039 Integrate action plan with each alarm condition H,M and L 268 87 36 44 82 232-1.037 0.2995 been proposed to improve clinical alarm performance is to ensure the alarm signal to indicate urgency to respond. It can be concluded that incorporation of the response time based on risk in the design of alarm, to indicate urgency to respond in auditory alarm signal can improve user response and patient safety. ACKNOWLEDGMENT I would like to acknowledge the Director General of Ministry of Health Malaysia, Director of Medical Device Authority, Director of Hospital Kuala Lumpur, Head of Department of Anesthesiology, staff of Main ICU, Hospital Kuala Lumpur and also to all those who participated in these studies for their contribution and support. REFERENCES [1] Kacmarek R. Alarms. In Principle and Practice of Intensive Care Monitoring. New York: McGraw- Hill, Inc; 1998, pp.133-139. [2] Meredith C, Edworthy J. Are there too many alarms in the intensive care unit? An overview of the problem. Journal of Advanced Nursing, vol.21, pp 15-20, 1995. [3] Vineet Chopra and Laurence F. McMahon Jr, Redesigning Hospital Alarms for Patient Safety: Alarmed and Potentially Dangerous. JAMA. vol. 311 (12): pp.1199-1200, 2014. [4] ECRI Institute, Top Health Technology Hazards for 2011 Health Devices, vol.39 (11), pp.404-16, 2010. [5] Cadet, Vladimir N., Safe Signals: Managing Clinical Alarm Systems for Optimal Performance Health Facilities Management, Vol. 27, No. 2, 2014. [6] Vineet Chopra, Laurence F. McMahon Jr, Hospital Alarms and Patient Safety JAMA, vol.312 (6), pp.651-652. 2014. [7] Imhoff M. and Kuhls S. Alarm Algorithms in Critical care Monitoring Anesthesia Analgesia, vol.102(50), pp.1525-1537, 2006. [8] Sanderson PM, Liu D, Jenkins SA. Auditory displays in anesthesiology Current Opinion in Anaesthesiology, vol. 22 - Issue 6, pp. 788 795, 2009. [9] McCartney P.R. Clinical alarm management American Journal of Maternal Child Nursing, vol. 37(3), 2012. [10] Tanner, T., The problem of alarm fatigue Nursing Women's Health, vol.17(2), pp.153-157, 2013. [11] Marie-Christine Chambrin. Alarms in the intensive care unit: how can the number of false alarms be reduced? Critical Care, vol. 5(4), pp.184-188, 2001. [12] Keller J.P. Clinical alarm hazards: A top ten health technology safety concern Journal of Electrocardiology, vol. 45, pp. 588-591, 2012. [13] Logan, M.K. A roundtable discussion alarm safety: A collaborative effort Horizons, vol. 45, pp. 8-15, 2011. [14] Wiklund, M. & Kendler, J. Complementing medical device alarms with animated guidance Horizons, vol. 45, pp. 67-71, 2011. [15] Patterson R. D. Auditory warning sounds in the work environment Philosophical Transactions of the Royal Society of London, Series B: Biological Sciences 327, pp. 485 492, 1990. [16] Burt JL, Bartolome DS, Burdette DW, Comstock JR Jr. A psychophysiological evaluation of perceived urgency of auditory warning signals Egronomics, vol.38(11), pp. 2327-2340, 1995. [17] Cvach,Maria. Use of Pagers with an Alarm Escalation System to Reduce Cardiac Monitor Alarm Signals Journal of Nursing Care Quality, Vol. 29 Issue 1, pp. 9 18, 2014. [18] Block FE Jr, Nuutinen L, Ballast B. Optimization of Alarms: A Study on Alarm Limits, Alarm Sounds, and False Alarms, Intended to Reduce Annoyance Journal of Clinical Monitoring and Computing, vol.15(2), pp. 75-83, 1999. [19] A. Guillaume, C. Drake, M. Rivenez, L. Pellieux, V. Chastres. Perception of urgency and alarm design, 8th International Conference on Auditory Display (ICAD), 2002. [20] ISO/IEC 60601-1-8:2006. Medical electrical equipment Part 1-8: General requirements for basic safety and essential performance. Collateral standard: General requirements, tests and guidance for alarm systems in medical electrical equipment and medical electrical systems 2006. [21] Block FE Jr and Schaaf C. Auditory alarms during anesthesia monitoring with an integrated monitoring system Int J Clin Monit Compu, vol.13(2), pp. 81-84, 1996. 1.8

[22] Topf, M. and Dillon E. Noise-induced stress as a predictor of burnout in critical care nurses Heat Lung, vol. 17, pp. 567-574, 1998. [23] Cropp A.J., Woods L.A., Raney D., Bredle D.L. Name that tone the proliferation of alarms in the intensive care unit Chest, vol. 105, pp. 1217 1220, 1994. [24] Kerr J.H. and Hayes B. An alarming situation in the intensive therapy unit Intensive Care Med, vol. 9, pp. 103 104, 1983. [25] Association for the Advancement of Medical Instrumentation. Clinical alarms AAMI Medical Device Alarm Summit, USA, 2013. [26] McIntyre, J. Ergonomics: anesthetist use of auditory alarms in the operating room International Journal of Clinical Monitoring and Computing, vol.2, pp.47-55, 1985. [27] Patterson, R. D. Auditory warning sounds in the work environment Philosophical Transactions of the Royal Society of London, Series B: Biological Sciences 327, pp. 485 492, 1990. [28] Edworthy, J., Hellier E.J., Walters, K., Weedom, B., and Adams, A. The relationship between task performance, reaction time, and perceived urgency in nonverbal auditory warnings The IEA 2000/HFES 2000 Congress, vol. 3, pp. 674-677, 2000. [29] Edworthy, J. The design and implementation of non-verbal auditory warnings Applied Ergonomics, vol. 25, 1994. [30] Hellier EJ, Edworthy J. On using psychophysical techniques to achieve urgency mapping in auditory warning Applied Ergonomics, pp. 30167-30171, 1999. [31] Hugo Fastl. Psychoacoustic basis of sound quality evaluation and sound engineering ICSV13, The 13th International Congress on Sound and Vibration, Vienna, 2006. [32] Hellier EJ, Edworthy J, Dennis I. Improving auditory warning design; quantifying and predicting the effects of different warning parameters on perceived urgency Human Factor, vol.35(4), pp. 693-706, 1993. [33] Edworthy J, Loxley S, Dennis I. Improving auditory warning design: relationship between warning sound parameters and perceived urgency Human Factors, vol. 33, pp. 205-231, 1991. [34] Maria Cvach, Monitor Alarm Fatigue: An Integrative Review Biomedical Instrumentation & Technology: vol. 46, No. 4, pp. 268-277, 2012. [35] USFDA. MAUDE, the Manufacturer and User Facility Device Experience Internet www.usfda.com [36] USFDA. What is human factor/usability engineering? Internet www.fda.gov.com [37] ACCE Healthcare Technology Foundation, Clinical alarm task force, Impact of clinical alarms on patient safety Journal of Clinical Engineering, pp. 22-33, 2007. [38] Bliss JP, Gilson RD, Deaton JE. Human probability matching behavior in response to alarm of varying reliability Ergonomics, vol.38(11), pp. 2300-2312, 1995. [39] Powell R.A. and Single H.M. Focus groups, International Journal of Quality in Health Care, vol. 8(5), pp. 499-504, 1996 [40] Christina Meredith and Judy Edworthy. Are there too many alarms in the intensive care unit? An overview of the problems Journal of Advanced Nursing, vol. 21, pp. 15-20, 1995. [41] Siebig S, Kuhls S, Imhoff M, Langgartner J, Reng M, Schölmerich J, Gather U, Wrede CE. Collection of annotated data in a clinical validation study for alarm algorithms in intensive care a methodologic framework J Critical Care, vol. 25, pp. 128 135, 2010. [42] Edworthy, J. and Hellier, D. Alarms and human behaviour: implication for medical alarms British Journal of Anaesthesia, vol. 97(1), pp. 12-7, 2006. 1.9