Essentials of Fiber to the Antenna: Fronthaul Installation Test

Similar documents
A Quick Start Guide to Fiber-to-theAntenna (FTTA) Installation and Maintenance Testing. Vol. 2 Tier 2 Certification

A Quick Start Guide to Fiber-to-the-Antenna (FTTA) Installation and Maintenance Testing. Vol. 2 Tier 2 Certification

TROUBLESHOOTING AT THE SPEED OF LIGHT EMBEDDED OTDR FOR OPERATIONAL EXCELLENCE IN PASSIVE OPTICAL NETWORKS

740C xwdm OTDR Series C-BAND DWDM AND 18-WAVELENGTH CWDM TUNABLE OTDR SERIES FOR METRO ETHERNET AND C-RAN LINK CHARACTERIZATION

The Rise of Tier 2 Testing

FTTH NETWORK TESTING: REAL APPLICATIONS USING THE OLTS METHOD

FLX380-30x FlexTester OTDR

FTB-730 PON FTTx/MDU OTDR OPTIMIZED FOR ACCESS FIBER DEPLOYMENTS AND TROUBLESHOOTING

VePAL FX300 Fiber Expert OTDR

FTBx-740C-DWC TUNABLE OTDR C-BAND DWDM METRO ETHERNET LINK CHARACTERIZATION

SmartClass and SmartPocket Optical Handhelds. Portfolio of Optical Handhelds for Fiber Field Test

FTB/FTBx-740C-CWDM Tunable OTDR 18-WAVELENGTH CWDM OTDR FOR METRO ETHERNET AND C-RAN LINK CHARACTERIZATION

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

Certified Fibre Optic Specialist - Testing

GO BEYOND OTDR LEAVE NO FAULTY NETWORK BEHIND. intelligent Optical Link Mapper

OTDR II. Tier-2 Optical Time Domain Reflectometer for Multimode and Single-mode Fiber Cabling

FTB-7400E Metro/CWDM OTDR METRO/CORE AND CWDM NETWORK FIBER CHARACTERIZATION

T-BERD 6000 Compact Optical Test Platform

Intelligent Optical Link Mapper (iolm)

Ensuring the Health of Tomorrow s Fiber LANs Part II OTDR Trace Analysis Become an Expert Troubleshooter with Advanced OTDR Trace Analysis

EOTec 2000 ControlNet Fiber Optic SHR/DSHR Communications Modules* With Support for Single and Dual Channel Self-Healing Rings

Optical Return Loss Measurement by Gregory Lietaert, Product Manager

OPX-BOX. Platform Highlights. Software Support. Key Features

intelligent Optical Link Mapper (iolm)

Hands-On CAT 5/6 & Fiber Optic Installer

Securing optical network physical layer with Fiber Monitoring and Management Vratislav Blažek Regional Sales Manager

The Definitive Handheld OTDR for FTTx Testing OTDR AXS Compact, lightweight handheld OTDR optimized for access/fttx network testing

Fiber Optics for Todays Industry Applications

EXECUTING HIGHLY ACCURATE FIBER MEASUREMENTS IN A FRACTION OF THE TIME

FTB-720 LAN/WAN Access OTDR OPTIMIZED FOR MULTIMODE AND SINGLEMODE ACCESS NETWORK TESTING

Fibre Characterisation and FTTx New challenges

FlexWave Element Management System. Alarm Reference FWPP May 2017

The True Value of Connector Inspection: New Challenges and Best Practices

Optical Fiber Monitor (OFM) Whitebox WB-OFM-1262-DC

Fiber Optic and CAT 5, 6, 7 and 8 Installer Premise Cabling

UC INSTRUMENTS GM8036 LASER SWEEP OPTICAL SPECTRUM ANALYZER (1525 ~ 1610 nm) Technical Specifications v1.01 March, 2011

Ensuring Cabling Performance in the Customer-Owned Outside Plant. Keith Foord Product Manager Greenlee Communications

DWDM OTDR with Tunable Laser MTP-200-D100. Hand-held High Performance OTDR. Series

Hands-On Fiber Optics ISP/OSP - Advanced Combo- Tech

Fiber Distribution Box

Cable Contractor Solution Overview

FTB-735C Metro/PON FTTx/MDU OTDR

AE2200 FTTx Multi-Function Meter

SYSTEM ENHANCEMENT MODULE

TRM 2.0 Test Results Manager All-In-One Comprehensive Analysis and Reporting Software

LAB REPORT SUBMISSION COVER PAGE ETN4106 OPTOELECTRONICS AND OPTICAL COMMUNICATIONS

P126FTT Fiber Transfer Terminal

Refurbished EXFO Instruments

Noyes OFL 250B Specs Provided by

Terahertz Technologies Inc Fiber Optic Test Equipment Catalog

MTTplus Modular Test Platform

Acterna MTS 5000 e Series OTDR and Loss Test modules

SERIES G: TRANSMISSION SYSTEMS AND MEDIA, DIGITAL SYSTEMS AND NETWORKS Transmission media and optical systems characteristics Optical fibre cables

ACCESS Master MT9085 Series. Product Introduction

FTBx-730C PON FTTx/MDU OTDR OPTIMIZED FOR FTTx/MDU FIBER DEPLOYMENTS AND TROUBLESHOOTING

Savitri Telecom Services

LAN/WAN OTDR FTB-7200 FTTx Access/Metro OTDR FTB-7200/7300 Metro/Long-Haul OTDR FTB-7400/74000 Long-Haul OTDR FTB-7500

Sterlite Tech Academy Creating Smarter Network Professionals

RC802/ B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual

USER MANUAL. WDM-D15xx.xx. Single Wavelength Add/Drop Module for DWDM

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Product Specification

Hands-On Fiber Optic ISP / OSP Combo-Tech Splicing, Termination & Testing

Ensuring Cabling Performance in the Customer-Owned Outside Plant

Basic Professional Fiber Optic Installation

M210 Multifunction Micro OTDR

Intelligent Optical Link Mapper (iolm)

Erbium-Doped Fiber Amplifier (EDFA) - MW Series

CMA4000i Optical Test System

FIBER OPTIC TESTING 1

FastReporter 2 DATA POST-PROCESSING SOFTWARE

M210 Multifunction Micro OTDR

Circuit balancing: A key to improving HVAC system operation and control

Extensive range of models covering all telecom testing applications. Flexible design, allowing up to three wavelengths in a single module

OTDR - FHO5000-xxx. Optical Time Domain Reflectometer

SECTION TESTING OF FIBER OPTIC CABLES

Kingfisher KI-3800 Light Source. Inexpensive handheld source for testing and commissioning optical fibre networks. Compact and rugged,

MicrOTDR. Optical Fault Locator. User Manual

LINEAR HEAT SERIES FIBER OPTIC LINEAR HEAT DETECTION SYSTEM

FACULTY OF ENGINEERING LAB SHEET OPTICAL COMMUNICATION SYSTEMS EOP4066 TRIMESTER 1 (2013/2014)

FiberSystem. Fiber Optic Linear Heat Detection for Special Hazard Applications

SECTION TESTING OF FIBER OPTIC CABLES

FastReporter 2 DATA POST-PROCESSING SOFTWARE

PLACEMENT BROCHURE Optoelectronics & Optical Communication(JOP) Official Website:

PROVEN PERIMETER PROTECTION NEW SINGLE-PLATFORM SIMPLICITY.

inet Now Live Monitoring

Event dead zone: 0.8 m. Attenuation dead zone: 4 m. Dynamic range: up to 50 db. Platform compatibility. FTB-200 Compact Platform

Field Test Procedure for Optical Fibre Link Measurements

FX150 OTDR. Platform Highlights. Key Features

FG-750 Client API SDN-READY INTELLIGENT OTDR

FTBx-750C Metro/Long-Haul OTDR LONG-DISTANCE FIBER CHARACTERIZATION AND FIBER UPGRADES

TRM 2.0 Test Results Manager All-In-One Comprehensive Analysis and Reporting Software

A dvan ced Fib er Opt ic Test Eq u ip me nt Terahertz Technologies Inc.

TECHNICAL - *All Pricing are Exclusive of VAT. Introduction to Fibre Optics for non-fibre Technicians (can also be done on-site) TARGET AUDIENCE:

M700-Series Multifunction OTDR

DIRECT CONNECT RESIDENTIAL ALARM SYSTEM Application Form

ANNOUNCEMENT ElectroniCast Consultants OTDR Market Forecast August 2017

User Manual. Portable 4-Channel Laser Source Instrument in Small Benchtop. (QLDS-N series, version 1.0a. March 26, 2014)

AE3100A~M Series 2-and 4-Wavelength Handheld OTDR

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Transcription:

Solution Brief Essentials of Fiber to the Antenna: Fronthaul Installation Test VIAVI Solutions 1 Fiber Inspection and Connectivity 3 Fronthaul Installation Test 2 Cable and Antenna Testing 4 Fiber Certification

Fronthaul Installation Test In distributed RAN architectures, CPRI protocol is used to connect remote radio heads (RRH), which are located close to the antenna, to the base band unit (BBU). CPRI protocol enables the RRH and BBU to interact with each other over distances of several miles. An extension of this distributed architecture allows service providers to co-locate a group of BBUs at a remote location; this phenomenon of centralization of RAN offers an enhanced capacity benefit by enabling ultra-dense cell deployments. Then by utilizing some of the key features of LTE Advanced, such as carrier aggregation and Uplink Coordinated Multipoint (UL CoMP), centralized RAN (C-RAN) can significantly improve uplink capacity and cell edge throughput. When installing RRHs on towers, street light and rooftops, it is extremely important to test the RRH links before connecting them to the BBU for service activation. Incorrect small formfactor pluggables (SFPs) and misconfigured or faulty RRHs will disrupt the service, necessitate the costly return of tower crews, and delay the service introduction. Additionally, in C-RAN architectures, multiplexing several signal wavelengths into a single fiber within the coarse wavelength-division multiplexing (CWDM) or dense wavelength-division multiplexing (DWDM) range is common when connecting the BBU to RRHs requiring specific CWDM and DWDM checks. Both CWDM and DWDM (and hybrids of the two) are common cost-effective strategies for expanding backhaul capacity without laying or lighting more fiber. Testing C-RAN is a little bit more involved when compared to macrocells. In addition to certifying all the cables, connectors, and other active and passive components, cell site installers may be required to validate new xwdm routes as well. Fronthaul testing consists of the following: 1. End-to-end link characterization of CWDM/DWDM routes for C-RAN type scenarios 2. CPRI check 3. BBU emulation test 2 Essentials of Fiber to the Antenna: Fronthaul Installation Test

Inspect Before You Connect Before performing any fiber test, it is essential to inspect and clean all fiber connectors involved in the test. The following table describes the distinct role of each test, as well as the VIAVI enhancements that provide unique, valuable advantages Test Description VIAVI Advantage Link Characterization of CWDM/DWDM Routes CPRI (Fronthaul) Installation Test BBU Emulation Test BERT Test Validates wavelength routes, and checks end-to-end loss through MUX and DEMUX. Also checks SFP wavelength and power level. Verifies the correct SFP is being used on the test set and confirms that the RRH is responding to the test set. For this test, it is recommended that the SFP that will be used in the BBU is used to confirm that it is functioning properly. When the test set establishes communication to the RRH by emulating a BBU, it confirms that the RRH has been properly installed and is responsive Establishes communication with the RRH by issuing commands to the RRH. The purpose of BBU emulation test is to confirm that the RRH has the correct SFP installed, that it has the correct firmware loaded, that fibers have not been swapped, and the RRH supports the expected sectors and frequencies. Confirms that any active components in the xwdm or dark fiber network are not creating CPRI frame loss that could impact service. Install and commission cell sites with one instrument and carry less equipment in the field Test new xwdm wavelength routes and pinpoint exact fault locations without disrupting traffic on active channels Verify end-to-end continuity with the integrated C-band tunable laser source mode Comprehensive qualification and troubleshooting solution, for hybrid CWDM/DWDM networks when combined with the VIAVI OTDR modules Easy setup and interpretation of results with SmartConfigs and Smart Link Mapper (SLM) OTDR applications Portable and lightweight, most compact xwdm OTDR solution available for physical layer fiber certification and troubleshooting VIAVI test solutions are approved by major service providers Our best in class industry warranty (3 years) gives you peace of mind and it shows our commitment to our customers 3 Essentials of Fiber to the Antenna: Fronthaul Installation Test

Channel/Wavelength Provisioning 1. Validate wavelength route birth certificate. Perform OTDR tests at specific CWDM or DWDM wavelengths (single ended test) and use tunable laser source with broadband power meter (dual ended test) during construction or once xwdm network is live (in-service) 2. Verify new CWDM/DWDM channel routing 3. Check end-to-end loss through MUX and DEMUX 4. Find dirty or poor connections Troubleshooting Live Network 1. Perform OTDR tests at a specific CWDM/DWDM wavelength on the live network (no traffic disruption) 2. Check end-to-end loss through MUX and DEMUX 3. Pinpoint fiber fault - find defective segment 4 Essentials of Fiber to the Antenna: Fronthaul Installation Test

Figure 1. Smart Link Mapper view of DWDM link/route To simplify interpretation of OTDR traces, VIAVI developed its Smart Link Mapper (SLM) capability. This application provides an easy to read icon based view of a fiber link (connector, splice, MUX, DEMUX, etc.) with intelligent MUX and DeMUX detection and identification and clear OTDR event icons, labels and descriptions. Instant toggling between OTDR trace and SLM view reduces the chance of OTDR trace interpretation errors and misdiagnosing faults, leading to faster job completion and reduced repeat truck rolls. 5 Essentials of Fiber to the Antenna: Fronthaul Installation Test

CPRI Check and BBU Emulation Performing CPRI check and BBU emulation tests during the installation phase will reduce need for additional tower climbs during the commissioning phase if installation-related issues are found. VIAVI CellAdvisor TM with BBU emulation lets technicians achieve more test coverage during the initial build process, identifying and isolating issues in one site visit to avoid repeat dispatches. Testing with BBU emulation also isolates problems more effectively and helps to identify problem sources such as fiber, coax, antenna, radio equipment, SFP, or RF. SFP Check Check SFP wavelength and power level with xwdm Channel Checker or Optical Spectrum Analyzer (OSA) Conclusion Whether you are working on a macrocell or a CRAN architecture, VIAVI T-BERD/MTS 5800 solution makes it easy to validate and turn up any kind of fiber fronthaul. Our comprehensive test solutions deliver acceptance reports per service provider test criteria, and are considered documented, authentic proof (birth certificate) that the installation meets specifications, enabling quick acceptance, and helping contractors get paid faster. Contact Us +1 844 GO VIAVI (+1 844 468 4284) To reach the VIAVI office nearest you, visit viavisolutions.com/contacts 2017 VIAVI Solutions Inc. Product specifications and descriptions in this document are subject to change without notice. Essentialftta-fronthaul-sb-nsd-nse-ae 30186272 900 1017 viavisolutions.com