PAC1500Xi PORTABLE APPLIANCE CHECKER

Similar documents
Operating Instructions

TESTSAFE. minipat APPLIANCE TESTER USER MANUAL

CLARE G2000. Comprehensive Test Station for The Lighting Association Code of Practice. Operator Manual. February Clare Instruments Ltd.

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

INSTALLATION & USER INSTRUCTIONS

Universal Clamp Meter

Installation & User Instructions: Model: e600s e600gf e700s e1000s e1000gf e1030gf/2/3 e1500gf/2/3

CAUTION - READ THESE INSTRUCTIONS BEFORE USING THE MACHINE

Important Notes: Please read carefully before installing your refrigerator.

SERVICE MANUAL. Ecoboiler Model range: T20 ( ) T30 ( )

LC2200 Level Controller Installation and Maintenance Instructions

UNDERCOUNTER SERVICE MANUAL. Ecoboiler UC4L 2.4kW Ecoboiler UC10L 2.8kW Ecoboiler UC10L 5.6kW Ecosmart UC4L 2.

Ecoboiler T20 & T30 SERVICE MANUAL. Marco Beverage Systems Ltd. 63d Heather Road, Sandyford Industrial Estate, Dublin 18, Republic of Ireland

Installation and user manual for the BiWire / Conventional Repeater Panel

ULTRASONIC HUMIDIFIER MODEL# BU6000 INSTRUCTION MANUAL

INSTALLATION & USER INSTRUCTIONS

Thermo-Sealer. Manual Heat Sealer. User Manual

LC3000 Level Controller Installation and Maintenance Instructions

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

INSTRUCTION MANUAL AMS WATER MANAGEMENT SYSTEM (AMS-WMS 230V) INSTRUCTION MANUAL AMS WMS 230V Manual Issue 1 15/10/09 Page 1 of 15

INSTALLATION & USER INSTRUCTIONS

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

INSTRUCTIONS MODEL: MFBU WET WELL BAIN MARIE

Tempest TP420/180 Electric Pressure Washer

RE-PR3-E-27 3-Phase Panel Mount 27kW

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

Contact Details. Please note that some of the contact details on this PDF document may not be current.

A4 Laminator. Installation & User Instructions Please keep for future reference 908/6197

Model 1174 Electric Heater User instructions for LED effect 2kw Inset Heater

INSTRUCTIONS MODEL: BT1 MOBILE BANQUETING TROLLEY

HYDROMIST LITE CARPET CLEANER OPERATOR MANUAL

5000 INSTALLATION GUIDE

INSTRUCTION MANUAL (English version) Water still

INSPECTION AND TESTING OF ELECTRICAL INSTALLATIONS: RESIDUAL CURRENT DEVICES

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

AQUARIUS 45 MARINE SERVICE MANUAL

Pie Warmer. Instruction manual. Model: GF454-A/GF455-A

MONITOR REFERENCE SERIES

Gasflag. Single Channel Control Panel Alarm Only Apparatus. Installation, operating and maintenance instructions, M07225.

INSTALLATION & USER INSTRUCTIONS

Induction Fryer. Instruction manual. Model Modèle Modell Modello Modelo Malli: CP793

Whole Room Dryer WRD, WRD/110

CARVER CASCADE 2 & CASCADE 2 GE CARAVAN WATER HEATER INSTALLATION INSTRUCTIONS LEAVE THESE INSTRUCTIONS WITH THE USER

EVP61/91/101/121. Extractor. Installation, use and maintenance.

Code of Practice // For the installation, inspection and testing of electrical installations tel/fax:

10yr O2NE & Safe-Ox. User Manual

highline SVCS-1 INSTALLATION & USER MANUAL SMOKE VENT CONTROL SYSTEM * enclosure design may vary software version: SVCS1r6 SVCS1r7 SVCS1r10

Installation & Operating Instructions. Models: York Midi & Serrano Electric Stoves

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

WELCOME BLUE - NEUTRAL BROWN LIVE GREEN AND YELLOW - EARTH

Mobile Air Conditioner Instruction Manual Model TC-N9KM

POWER SHOWERS Models 4500M 5002M 4500T 5002T

INSTALLATION AND USER INSTRUCTION GUIDE. Model (s) Electric Heater Model No s FRER**ME2 / FSER**ME2 / FMER**ME2. ** Denotes case colour / finish

Instruction Manual M6627 / Version 7.4. Slide Drying Bench MH6616 MH6616X1

EDD61 & EDD91 Extractors

Water Bath SWB1 SWB2 SWB3 SWB1D SWB2D SWB3D. Instructions for use Version 2.0. water bath SWB2D. mains on on. press to set. set. off.

Hydrosense. Vimpex Limited. Star Lane. Great Wakering. Essex SS3 0PJ. Tel: +44 (0) Fax +44 (0)

Ultracom hxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

COLD WATER WASHER OPERATING & MAINTENANCE INSTRUCTIONS. Model Nos. ELS140, 140R & ELS150. Part Nos , &

ANNEALING FURNACE MODEL 414 User Maintenance Manual/Handbook

BX444-Mc Gas Detector

C106 Coded Access Keypad

MW001 Integrated Dishwasher. Manual for Installation, Use and Maintenance

User Instructions for Remote Controlled 2kW Rotisserie Effect Fan Heater Model 1276

Marco Beverage Systems Ltd. INSTRUCTIONS FOR MODELS

Autofill wall mounted water. boiler. Getting the best from your water. boiler. Please read and keep these instructions

SHORT WAVE INFRARED PANEL DRYER

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

MURELLE EV HE 25/55-30/55

INSTALLATION & USER INSTRUCTIONS

Model PT-05 Model PT-06

INSTRUCTION MANUAL. DECKMA HAMBURG GmbH. Type OMD-12. Oil-in-Water Monitor

British Gas 330+ High Efficiency Condensing Boiler. Instructions for Use. To b e l e f t w i t h t h e u s e r. British Gas Service Tel:

Operator s Manual. IP-100 Immersion Probe Cooler

ELECTRIC ASHCAN MODEL NO: ASHVAC1200 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: ORIGINAL INSTRUCTIONS

Replacing a consumer unit in domestic premises where lighting circuits have no protective conductor

Optimax Refrigerated Retail Merchandisers

Marco Beverage Systems Ltd.

DOMESTIC STEAM GENERATOR Installation Instructions

Archive. LC2200 Level Controller. 1. Safety information. 2. General product information. 3. Installation. 4. Setting up the controller

Proline GAS HOB Model TCG40IX Instruction Book

Installation & User Instructions:

TH100 Three in One Instant Hot Water Tap

AlcoBlow. User Handbook

SUBMERSIBLE WATER PUMPS

IMPORTANT- RETAIN FOR FUTURE REFERENCE CALL:

ANALOX 101 D2 PORTABLE OXYGEN MONITOR USER MANUAL

CERAMIC HEATER MODEL NO: DEVIL 350B 230V/110V OPERATING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS GC ISS 1

USER MANUAL LEEC CLASSIC INCUBATOR. C100, C157 and C330

Installation, operating and servicing instructions

Instruction Manual. Please read these instructions and the Safety section carefully before using your refrigerator.

SMARTELEC 2 ENERGY SAVING CONTROL INSTALLATION AND OPERATING MANUAL

NEPTUNE Tubular MI Electric Immersion Heater

ELECTRIC ASH CAN Model: CVACASH500 Part No:

THE MEDIX Actineb. Technical Specifications. % Particles < 5 um 75% * Class II BF. Intermittent (use for 60 Type Rating

PTC Tower Heater. Instruction Manual THE SCIENCE BEHIND HEAT.

User Instruction Manual

Statesman 45/50L, 50/70L, 70/90L, 90/110L, Utility 50/70L, 70/90L, 90/110L, 110/130L, 130/150L

Oil Panel Heater Instructions for Use

275HVD NON-CONTACT, HIGH VOLTAGE DETECTOR DETECTOR DE ALTA TENSIÓN SIN CONTACTO

Transcription:

PAC1500Xi PORTABLE APPLIANCE CHECKER OPERATING INSTRUCTIONS 211A912 CONTENTS 1) Safety... 1 2) Introduction & Description... 2 3) Applications... 2 4) Test Sequence... 3 5) Visual Inspection... 3 6) Earth Bond Test... 3 7) Insulation... 5 8) Fig 1 & 2 240V Connector... 6 9) Test Results... 7 10) Warning... 8 11) Maintenance... 8 12) Specification... 10 13) Replacement... 10 Bracken Hill, South West Industrial Estate, Peterlee, Co. Durham SR8 2SW. England. Tel: 0191-586 3511 Fax: 0191-586 0227 www.seaward.co.uk sales@seaward.co.uk calibration@seaward.co.uk

IN THE INTEREST OF SAFETY THIS INSTRU- MENT SHOULD ONLY BE USED BY COMPETENT, SUITABLY TRAINED PERSON- NEL AFTER DUE CONSIDERATION OF ANY HAZARD INVOLVED 1. SAFETY Read instructions before use. Due to the potential hazard associated with any electrical circuit it is important that the user is fully familiar with the instructions covering the capabilities, applications and operation of this instrument. The user should ensure that all reasonable safety procedures are followed and if any doubt exists should seek advice before proceeding. The PAC1500Xi performs a number of electrical tests which involve high voltages and high currents. Never touch the appliance being tested while the testing procedure is being followed. This product is designed for use by suitably trained competent personnel. Before using the PAC1500Xi ensure that you have read and thoroughly understood the instruction manual. The PAC1500Xi has been designed to conform with the general safety requirements of IEC1010. Various terminals on the product are used for working at potentially hazardous voltages and the equipment should therefore be used only after careful study of these instructions. 1

INTRODUCTION & DESCRIPTION The PAC1500Xi is an advanced portable appliance checker which performs tests on Class 1 or Class 2 equipment. These tests are Earth Bond Resistance and Insulation Resistance as required by the Electricity at Work Regulations 1989. The equipment is controlled by solid state electronics and enables the user to easily select and perform the required tests. Particular features of the specification are; Tests Class 1 and Class 2 equipment. Allows Earth Bond measurements to be conducted at low currents (100mA). Earth Bond currents are electronically controlled for accuracy and safety. Clear digital display with electronic hold of last reading at end of test. Additional BS4343 socket for testing 110V appliances. Layout The PAC1500Xi is contained in a robust ABS/Polycarbonate injection moulded case which accommodates all the high voltage, power and control components in the base section and the measurement and display electronics in the lid section. The lid section features a large LCD for the display of measurements and OVERFLOW and FUSE OK LED indicators. The OVERFLOW indicator will illuminate when any reading exceeds 1999 on the LCD display. A sturdy zip pouch located at the rear of the instrument contains all the necessary test leads and the mains supply connector. Access is also available to additional test sockets for 4 wire Earth Bond tests and remote Insulation Resistance measurements. The base control panel of the instrument features a rotary switch for test selection and a push button test switch with associated LED indicators. A number of safety features are included in the instrument design and these include; 1) Fuse protection. 2) Thermal trip on electronic components to prevent failure due to over heating of unit. 3) Fail-safe crowbar system to prevent internal test relays from being continuously powered in the remote possibility of failure of the control electronics. The use of the PAC1500Xi is straight forward and involves connecting the checker to a mains supply which powers the electronic circuitry. Plug the appliance under test into the instrument socket outlet on the top plate and connect the test leads appropriate to the insulation class of the appliance. APPLICATIONS The PAC1500Xi is designed to check the electrical safety of portable appliances and its use allows for appliances of Class 1 and Class 2 to be checked. As a guide BS and IEC standards define these two categories of insulation as follows; Class 1 Class 2 Appliances which have a functional insulation throughout and have exposed conductive (typically metal) parts connected to earth. These are often described as earthed appliances. Appliances which have both functional and additional insulation and where any metal parts cannot become Live under fault conditions. 2

The symbol represents double insulation and no earth connection is present in this type of appliance. Different regulations and standards describe a variety of tests for electrical appliances and in general cover approval tests. Such testing involves prolonged sophisticated tests. It is generally recognised that for periodic inspection to ensure the safety of the appliance is maintained, tests of the type performed by the PAC1500Xi are realistic and satisfactory. TEST SEQUENCE The PAC1500Xi should be connected to the mains power. There is no power switch and the unit will be ready for use within a few seconds of applying mains power. A green READY indicator will illuminate when the PAC1500Xi is prepared for tests, the display will not show any readings when the READY indicator is illuminated. It should be noted that there are two safe positions on the rotary switch. These are; a) between the 25A Earth Bond Test position and the Insulation Test position and b) at the fully counter clockwise position of the selector switch. In either of these positions the PAC1500Xi is inert and will not conduct any tests irrespective of the TEST push-button. Do not touch the appliance while testing is in progress. VISUAL INSPECTION Before commencing testing the user should undertake visual checks on the mains lead, case and fuse of the appliance under test. There should be no evidence of damage of a nature that may impair the electrical safety of the item. EARTH BOND TEST General It is important that the PAC1500Xi is used to test appliances in the following sequence. Failure to follow this sequence may lead to incorrect test results and unsafe equipment being released back into use. Failure of any test must result in the appliance under test being rejected and quarantined until any faults are repaired and the appliance satisfactorily re-tested. The objective of this test is to ensure that the connection between the earth or protective conductor of the appliance s mains supply earth pin and the metal casing of the appliance is satisfactory and of low enough value to satisfy accepted safety standards. The development of business machines (such as computers & VDU s) has necessitated the introduction of a low voltage/low current test range in order to allow tests on these appliances to be conducted without fear of damage being caused by the use of a higher test current. Type A tests These are the common form of Earth Continuity tests utilising test currents of 6A, 12A 20A & 25A at an open circuit voltage of 6V RMS. 3

Type B tests This is a form of Earth Continuity test utilising test currents of 100mA at an open circuit voltage of 500mV RMS. The low current prevents damage to the appliance under test, the low voltage will assist the detection of loose connections and is less likely to break down surface corrosion films at defective connections. For this reason when conducting such a test it is vital to ensure that good connection is made between the test leads and the device under test. It is advisable to consult the manufacturer to obtain the appropriate test current and test point(s) on the accessible conductive parts for each type of equipment. Connections The appliance should be connected as per figure 1 ensuring that all connections are firmly made and that the Earth Bond Test Leads are correctly inserted according to the colour coded plugs and sockets. The PAC1500Xi should be set to EARTH TEST selecting the appropriate test current for the appliance. Procedure The test should be initiated by depressing the TEST push-button. This button must remain pressed throughout the duration of the test. If for any reason the test button is released the test will be aborted. At the start of the test the READY indicator will extinguish and the TIMEOUT indicator will light showing test signals are being applied to the appliance. The LCD display will show the Earth Bond resistance throughout the test. At the end of the 6 second test the TIMEOUT indicator will extinguish and the LCD display will continue to hold the last test reading. Test signals are no longer applied to the appliance. The TEST button can be released. After a further period of 6 seconds the LCD display will switch off and the READY indicator will illuminate showing that the PAC1500Xi is ready to commence a further test. Until the READY indicator lights further depressions of the TEST button will not initiate tests. The TEST button must be released and depressed to initiate a test. Continual depression of the switch will not result in a continuous sequence of tests. The test should be repeated for each area of exposed metalwork. Notes on Results It may be noted that the earth bond resistance of the appliance may change during the test. Before rejecting the appliance care should be taken to ensure that the following mechanisms are not causing the variance; 1) Bad connection of the test leads, this is particularly critical at low test currents. Ensure that the connections are firmly made onto clean surfaces. 2) Thermal effects. Wire increases in resistance with an increase in temperature. At high current levels the PAC1500Xi is capable of generating sufficient heat within connection leads which will be detected by the high resolution of the display. Care should be taken to ensure that repeated tests do not damage the appliance. 4

4 Wire Tests If the appliance is not fitted with a 13A plug or an Earth Bond test is required between two components of the appliance then the PAC1500Xi can be used in a 4 wire mode. A second Earth Bond test lead is connected to the green and black sockets within the pouch (at the rear of the instrument) taking care to ensure correct connection as per the colour coding. The two leads can then be connected across the earth bond requiring test and the test carried out in the manner described in the previous section. If this method is used it is important to ensure that the appliance is no longer plugged into the 13A socket on the top plate of the PAC1500Xi. Technical The PAC1500Xi applies a low voltage between the earth pin of the top plate 13A socket and the lead connected to the earth bond test terminal. An electronically controlled current of a value set on the top plate selector switch is allowed to flow for a period of 6 seconds (or until the TEST button is released whichever is the shorter). The objective of the test current selected is to test the appliance under load conditions (and as such the test current must be selected to reflect these load conditions) and the duration of the test is limited to 6 seconds to prevent damage or over-stressing which may be caused by testing for prolonged periods. INSULATION General The objective of this test is to ensure that the insulation between the phase or neutral conductor of the appliance s mains supply and the metal casing of the appliance is satisfactory and of high enough value to satisfy accepted safety standards. Connections For Class 2 tests the appliance should be connected as per Figure 2 ensuring that all connections are firmly made and that the Insulation Test Lead is correctly inserted according to the colour coded plugs and sockets. For Class 1 appliances do not use the Test Lead. The PAC1500Xi should be switched to INSULATION TEST. The appliance under test must be switched on. Procedure The test should be initiated by depressing the TEST push-button. This button must remain pressed throughout the duration of the test. If for any reason the test button is released the test will be aborted. At the start of the test the READY indicator will extinguish and the TIME OUT indicator will light showing test signals are being applied to the appliance. The LCD display will show the Insulation Resistance throughout the test. For Class 2 appliances the insulation test lead should be touched on all exposed metalwork of the appliance under test ensuring that at all times the insulation resistance satisfies the accepted safety standards. At the end of the 6 second test the TIME OUT indicator will extinguish and the LCD display will continue to hold the last test reading. Test signals are no longer applied to the appliance. The TEST button can be released. 5

Figure 1 Earth Bond Test 25 Amps - 100 ma 240V CONNECTOR Figure 2 Insulation Test 500V DC (Probe not needed for earthed appliances i.e. Class 1) 6

After a further period of 6 seconds the LCD display will switch off and the READY indicator will illuminate showing that the PAC1500Xi is ready to commence a further test. Until the READY indicator lights further depressions of the TEST button will not initiate tests. The TEST button must be released and depressed to initiate a test. Continual depression of the switch will not result in a continuous sequence of tests. Results The indicated resistance should typically be in excess of; Class 1... 2MΩ Class 2... 7MΩ Technical The PAC1500Xi applies a nominal 500V DC between the earth pin of the top plate 13A socket and the Phase & Neutral pins which are connected together during the test for a period of 6 seconds (or until the TEST button is released whichever is the shorter). The additional earth connection available on a test lead is to test all exposed metal work on the appliance ensuring that minimum insulation levels are held at all points on the appliance. TEST RESULTS Each appliance tested should exhibit the following test results; Correct Test Results Class 1 Class 2 (Earthed) (Double Insulated) Visual UNDAMAGED UNDAMAGED Earth Bond see equipment manufacturers Insulation safety spec. Any other test results suggests a defective appliance. FUSE TEST General The objective of this test is to confirm the integrity of the appliance fuse. Connection The appliance should be plugged into the PAC1500Xi front panel 13A or BS4343 socket The appliance under test must be switched on. The PAC1500Xi should be switched to fuse test. Procedure The test is initiated by pressing the TEST push-button. This button must remain pressed throughout the duration of the test. If for any reason the test button is released the test will be aborted. The FUSE OK indicator will illuminate to confirm the integrity of the appliance fuse. Technical A low current limited AC voltage of 9 volts is applied to the appliance and the current flow detected and indicated. The circuit will indicate for circuit resistance of 1KΩ Ohms i.e. appliances 50W. Certain appliances that contain semiconductors within the power circuit may not give a correct indication of fuse integrity. 7

WARNING a) Do not touch the appliance while testing is in progress. A high voltage of 500V is applied with respect to earth during the Insulation Test. b) Ensure that the earth clip of the bonded earth test cable is securely attached to the appliance. A poor connection may result in arcing of the contact. c) If it is unclear which Class of insulation applies to the appliance being tested it is recommended that the manufacturers operating instructions be consulted. d) It is recommended that the PAC1500Xi is periodically checked by testing an appliance of known electrical characteristics. e) If the PAC1500Xi is used to conduct a series of Earth Bond tests the internal circuitry will heat up. It is recommended that the PAC1500Xi is allowed to recover for a short period between close sequences of tests. f) If the PAC1500Xi does overheat a thermal trip will trigger removing the supply from the unit. In this case the PAC1500Xi should be allowed to recover for a reasonable period to allow the internal circuitry to cool. The thermal trip is only likely to trigger in the event of an extended sequence of Earth Bond tests. g) The PAC1500Xi contains a safety device which will trigger if the internal circuitry fails causing the unit to power either the Insulation test or Earth Bond test circuitry continuously. This can be reset by removing the power from the PAC1500Xi for a few seconds and then reconnecting it. In normal use this should not arise thus in the event of this occurance the unit should be returned for service. MAINTENANCE The PAC1500Xi is a rugged, quality instrument. However care should be taken in its use, failure to do so will reduce the instrument s life and hinder its reliability. 1) Always check all test leads for signs of damage prior to use. 2) Always check the PAC1500Xi for signs of damage prior to use. 3) Keep the PAC1500Xi clean and dry. If the instrument requires cleaning disconnect from the mains supply and wipe clean using a cloth moistened with weak detergent solution or a proprietary foam instrument cleaner. 4) Avoid testing in conditions of high electrostatic or electromagnetic fields. 5) No attempt should be made to gain access to the instrument whilst under test conditions. 6) Maintenance should only be performed by authorised personnel. The PAC1500Xi contains no user serviceable parts. Should the PAC1500Xi require service, repair or calibration, return the equipment to a recognised dealer or to; Seaward Electronic Ltd. Bracken Hill, South West Industrial Estate, Peterlee, County Durham SR8 2SW England. Tel: (0191) 586 3511 Fax: (0191) 586 0227 8

The PAC1500Xi should be returned, post paid, where upon receipt, the owner will be advised of any costs prior to work commencing (unless the unit is still within warranty). Overseas If the instrument owner resides outside the U.K. he may either return the instrument directly to Seaward Electronic Ltd. at the address above, or to his local sales agent, a list of whom may be obtained from Seaward Electronic Ltd. It is important that if the unit is returned to Seaward Electronic Ltd. a copy of the invoice and packing note are sent via airmail in order to clear the unit through customs. 9

SPECIFICATION Earth Bond Test AC Test Currents... 6A, 12A, 20A, 25A @ 6V RMS (nominal) Corresponds to Type A earth continuity tester as defined in Electricity at Work Regulations 1989.... 100mA @ 500mV RMS (nominal) Corresponds to Type B earth continuity tester as defined in Electricity at Work Regulations 1989.... Electronically controlled constant current to ± 20% accuracy. Note: the current will only be controlled within an acceptable test load impedance. Display Range... 0>1.999Ω Accuracy... ± 10% or 1mΩ whichever is the greater. ± 2 counts. Note: Impedance of the earth connector will be significant at low impedances. Resolution... 1mΩ Test Duration... 6 seconds nominal Insulation Test DC Test Voltage... Display Range... Accuracy... Resolution... Test Duration... Fuse Test AC Test Current... Display... Display Indication... Protection... 480V min, 600V max off load 10kΩ to 19.99MΩ ± 3% or 10kΩ (whichever is the greater) up to 15.00MΩ 10kΩ 6 seconds nominal 30 ma max, 9V o/c LED Indicator 1KΩ Internal Fuse Supply Voltage AC Supply... 240V ± 10% @ 50Hz Note: Some readings and specification figures are related to supply voltage variation Physical Data Dimensions... 250mm x 200mm x 150mm (approx) Weight... 4 kilo (approx) Temperature Range... 0 to 40 C (operating), -10 to 70 C (Storage)... Thermal cut-out will operate when internal components attain 70 C in order to prevent damage REPLACEMENT PARTS Earth Lead... 207A915 Insulation Probe... 207A918 FUSES Plug Fuse... 5A to BS 1362 There are no user serviceable parts within the unit. Due to a policy of continuous development Seaward Electronic Limited reserves the right to alter equipment specification and description outlined in this publication without prior notice and no part of this publication shall be deemed to be part of any contract for the equipment unless specifically referred to as an inclusion within such contract. 211A557-B 10

Environmental Conditions Operating temperature range: 0-40 C Relative Humidity: Max 80% up to 31 C; 50% to 40 C indoor use altitude up to 2000 metres installation category II pollution degree 2