Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

Similar documents
Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

Description. Optex Incorporated

Advanced DIGITAL Wired PIR Motion Detector

IN A BOX. User Manual YOUR HOME SECURITY SYSTEM. curv360.co.uk. Support APP remote arm/disarm, parameter settings and accessories management

LUX Hardwired - Installation Notes

English. Italiano. Português. Françias. Español

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

Passive Infrared Motion Detector 5420/90P. Installation Instructions

M O T I O N DETECTORS. The Paradox series of motion detectors. combines advanced features and patented. technologies to provide a high level of

DS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector

RILEVATORI DI MOVIMENTO DA INTERNO serie unum

Hardwired Alarm Accessories

DS160/161 Request To Exit PIR sensors Installation Instructions

DS160/DS161 Request To Exit PIR sensors Installation Instructions

ISC-PDL1-W18G-H. Installation Instructions Professional Series Dual Detector

PIR-100B User Manual

Flash 3 times per 3 seconds: Under voltage indication, please

D-Tect 2 GJD300 Quad PIR Movement Detector

Dual Technology Wall Switch Occupancy Sensor. Manual & Specification

design line performance line Guardall DesignLine & PerformanceLine detector series 2015 Peace of mind

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

HX-80NRAM. High Mount Outdoor Detector

D-TECT Dual Tech. GJD360 Triple Technology External Detector

PSC-BL-I-FM-DC0(-BLE) Bi-level Dimming PIR Sensor

INTERNAL DETECTORS. Wired and two-way wireless grade 2 and 3 internal detectors

LC-151 Dual-Tech Motion Sensor (Single PIR & Microwave) with adjustable Pet Immunity INSTALLATION INSTRUCTIONS & USER MANUAL P/N: ver.

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

CM-RQE70A PIR REQUEST TO EXIT DETECTOR

Sensors and Detectors

DT900 Series Sensors TECHNOLOGY FOR LARGE COMMERCIAL AND INDUSTRIAL APPLICATIONS. Impressive Performance, Impressive Coverage

DI601AM Outdoor PIR/AM Detector Installation Sheet

HDCVI PIR Camera User s Manual

DUAL ZONE OUTDOOR PIR MS-12TE & MS-12FE

WIRELESS OUTDOOR DUAL TECHNOLOGY MOTION DETECTOR AOD-200

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions.

GJD OPAL RFX WIRELESS 35 METRE EXTERNAL PIR INSTALLATION MANUAL

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor

HX-40/40AM/ 40DAM. High Mount Outdoor Detector

EWP2WIRELESS MOTION DETECTOR

2 x CR123A Lithium batteries. White night-light LED. Blue alarm LED - also glows behind the lens. Ambient light sensor behind lens.

Commercial Series TriTech Motion Detector. Reference Guide

Installation Instructions

Honeywell ENERGY SAVINGS KIT

NTI ENVIROMUX-SDS-CELC(P) PHOTOELECTRIC SMOKE DETECTION SENSOR. Installation Instruction. Introduction. Product Features

IP65 High Bay Dual Sense Sensor

General Description. Industrial LuNAR DT AM Grade 3 Features

S3 Sim Secual Alarm system with GSM transmitter

Commercial Series TriTech+ Motion Detector with Anti-mask

Microwave/PIR Intrusion Detector with POPIT Interface ZX970

KwêBeams Effective wire free outdoor early warning system

64.7 Ø85. (1) Sensor inset (2) Lens pluggable. (3) Protection cover (covers the high-voltage terminals). (4) Ceiling (drill hole Ø70mm).

SYSTEMS GROUP. May Zilog and EE-SGI Present. epir TM. The Next Generation of PIR Motion Detector Technology. (Over View)

Extended Range DUAL TEC Motion Sensor

RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Guide

Intrusion Outdoor Protection Perimeter

v3 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On feature

Infrared Ceiling Mount Sensor

alarm shop Outdoor PIR + MW Detector with Double Dual Mirror Optics INSTALLATION INSTRUCTIONS & USER MANUAL ELECTRONIC ENGINEERING LTD.

Technology. Occupancy & Vacancy Sensors & Timers. Technology. Occupancy & Vacancy Sensors & Timers L-2

STANDARD FEATURES SPECIFICATIONS

IX30 - Z-Wave PIR Detector User Guide

DT8050A DUAL TEC Motion Sensor with Anti-Mask - Installation Instructions

Active Infrared Multi Beam Sensors

2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T F E. cristalcontrols.

Passive Infrared (PIR) Wall Switch Occupancy Sensor Dual Circuit

High Mount. Low Mount. High security wired tri-technology external detectors with anti-masking

Active Infrared Multi Beam Sensors. R Series

CS1200 WHT Pir Ceiling Mount Occupancy Sensor

1126 Series Ceiling Mount PIR Motion Detector

D-TECT 3 IP. GJD260 IP Motion Detector

Movement Detector GJD 300

180 Degree Ceiling Mounted Occupancy Sensors

SMS GSM Alarm Messenger

DUAL TECHNOLOGY SENSOR (PIR + Microwave) Outdoor use INSTALLATION MANUAL

Wireless PIR Sensor with Transmitting Distance:300~500m

Installation Instructions

IP65 High Bay Dual Sense Sensor

CDR-AL Room CO 2 Traffic Light Alarm Units and Sensors

UBC Technical Guidelines Section Edition Access Control Page 1 of 5

INSTALLATION AND USER MANUAL SG2. GSM+WiFi. Alarm Security System

D-TECT 2 IP. GJD230 IP Motion Detector

>WIRELESS> ALARM SYSTEM CR200

Elite. GJD022 /GJD023 35m External PIR. Multi Beam Lens Data

DH400. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer.

English. Series. Installation and Use Manual

EXPANDABLE SMART HOME SECURITY KIT

DS860 Surface or Corner Mount TriTech PIR/Microwave Detector

LS800S Intruder Alarm System. Engineering Manual

Motion Sensor. For Outdoor Use. Wall & ceiling mounted. Quick & Easy Installation 2 Channels

Pyroelectric Infrared Radial Sensor

powered by Note: This manual applies to several packages. As such, some parts and some steps may not pertain to the package that you purchased.

DUAL OPTIC. Installation manual

DT8016AF4 / DT8016AF5 DUAL TEC Motion Sensor with Anti-Mask Installation Instructions

Infrared Ceiling Mount Sensor

FEATURES OPTION 1.DESCRIPTION AND OPERATION 2.DETECTION AREA PASSIVE INFRARED AND MICROWAVE COMBINATION DETECTOR. No.

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

DHR3. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer. INSTALLATION INSTRUCTIONS

Movement-based energy control

Premium 8 Zone Wireless Alarm Kit

Quick Selection Guide Intrusion Detectors

Transcription:

LS-818-3 Descriptions Temco s Passive Infrared Occupancy Sensor is a low cost comercial and residential surface mount occupancy sensor. Advanced filtering reduces false triggering due to air movement and lighting changes. The sensor switches a dry contact which is wired to a separate controller. There is a tamper switch terminal as well, when the enclosure is opened up the central controller will be able to signal an alert. Main Features: - Intelligent logic control, anti false alarm efficiently - Auto temperature compensation - Pulse count adjustment - Anti white light interference - Anti RF interference (20V/m-1GHz) - Fresnel lens - Wall installation - SMT design adopted - Alarm output N.C./N.O. Optional Product Profile Technical Specifications Operating voltage: LS-818-3-24VAC: 24VAC, 1VA; LS-818-3-12VDC: 9 to 12VDC,100 ma Current consumption: 12VDC, 18mA ; 24VAC, 18mA Detection distance: 12m Detecting angle:110 o Self-testing time: about 60S Operating temperature: -10~+50 o C Alarm indicator: red LED Alarm output: Jumper selectable as N.C.or N.O., DC28V, 100mA Anti tamper switch output: Dry contact DC 28V max, 100mA max Occupancy Sensor output: solid state, jumper selectable NO or NC, DC28 V,100mA max. Coverage range: 11 meters,110 o Sensor: dual element infrared sensor Environment humidity: 95%RH (non condensing) Anti RF interference: 10MHz ~ 1GHz 20V/m Mounting: Wall mount Installation height: 1.7~2.5m Outline Size: 59(L) * 39.5(W)* 107(H) mm - 1 -

Terminal Block & Jumper Settings Detecting Area View Installation Notes - Avoid install at the out door, places with pets, air-conditioning nearby,derect sunshine,heat source and under rotating objects. - Surface of installation should be firm with no vibration. - Installing the detector in the place where intruder passes easily. Installation Steps 1. Screw the detector bottom off, then open the detector. 2. Screw the PCB off and remove the PCB. 3.Drill a wire hole in the rear housing. 4. Install the rear housing on the suitable position. 5. Connect the terminal block. - 2 -

Operating Instructions Function Setting: 1. Relay Jumper: Choose N.C. or N.O. to set the state of alarm output. according to the alarm panel or controller requirements, NC being the default. Short 1&2: N.O. Short 2&3: N.C. 2. Sensitivity Jumper: Three settings for low medium and high sensitivity. Note however that setting high sensitivity also increases the possibility of interference from RF. If you are getting false triggering, try setting the sensitivity down one level. The default setting is high. Short 1&2: High sensitivity. Short 2&3: Medium sensitivity. Shut off: Low sensitivity. 3. LED Jumper: This jumper simply enables/diables the on board LED and does not affect the operation of the sensor itself. If the application calls for it you can conceal the detection indication by disabling the LED. Short 1&2: LED will trigger when motion is detected. Short 2&3: LED will be off always. Product Setup: Turning on power and LED indicator will be enabled regardless of the LED jumper settting so as to enable sensing activity confirmation during commissioning and maintenance. This lasts about 60s after which the LED will be enabled or disabled depending on the LED jumper position. Notice 1. Please install and use the detector according to this manual, don t touch the surface of sensor avoid affecting the sensitivity of the detector. Please shut off power and then clean the sensor by soft cloth with little alcohol if cleaning needed. 2. The product can reduce accident but may not perform as expected. The user is advised to take all necessary precautions for his/her safety and the protection of his/her property. 3. In order to ensure it can work normally, the power should be kept to supply and get on walking test periodically, once a week is better. - 3 -

LS-818-6 Descriptions Temco s Passive Infrared Occupancy Sensor is a low cost comercial and residential surface mount occupancy sensor. Advanced filtering reduces false triggering due to air movement and lighting changes. The sensor switches a dry contact which is wired to a seprate controller. There is a tamper switch terminal as well, when the enclosure is opened up the central controller will be able to signal an alert. Main Features: - Intelligent logic control, anti false alarm efficiently - Auto temperature compensation - Pulse count adjustment - Anti white light interference - Anti RF interference (20V/m-1GHz) - Fresnel lens - ceiling installation - SMT design adopted - Alarm output N.C./N.O., Anti RF Interface Product Profile Technical Specifications Operating voltage: LS-818-6-24VAC: 24VAC, 1VA; LS-818-6-12VDC: 9 to 12VDC,100 ma Current consumption: 12VDC, 18mA ; 24VAC, 18mA Detectiion distance: Diameter 8m when mounted @ 3.6m Detecting angle:360 o Self-testing time: about 60S Operating temperature: -10~+50 o C Alarm indicator: red LED Alarm output: Jumper selectable as N.C.or N.O., DC28V, 100mA Anti tamper switch output: Dry contact DC 28V max, 100mA max Occupancy Sensor output: solid state, jumper selectable NO or NC, DC28 V,100mA max. Coverage range: 11 meters,360 o Sensor: dual element infrared sensor Environment humidity: 95%RH (non condensing) Anti RF interference: 10MHz ~ 1GHz 20V/m Mounting: Wall mount Installation height: 2.5 ~ 6m Outline Size: 106(Dia.) * 36(Thickness) mm - 4 -

Terminal Block & Jumper Settings Detecting Area View Installation Notes - Avoid install at the out door, places with pets, air-conditioning nearby,derect sunshine,heat source and under rotating objects. - Surface of installation should be firm with no vibration. - Installing the detector in the place where intruder passes easily. Installation Steps 1. Turn the detector counterclockwise, remove the front cover. 2. Screw the PCB off and remove the PCB. 3. Drill a wire hole in the rear housing. 4. Install the rear housing on the suitable position. 5. Connect the terminal block. 6. Put back the front cover. - 5 -

Operating Instructions Function Setting: 1. Relay Jumper: Choose N.C. or N.O. to set the state of alarm output. according to the alarm panel or controller requirements, NC being the default. Short 1&2: N.O. Short 2&3: N.C. 2. Sensitivity Jumper: Three settings for low medium and high sensitivity. Note however that setting high sensitivity also increases the possibility of interference from RF. If you are getting false triggering, try setting the sensitivity down one level. The default setting is high. Short 1&2: High sensitivity. Short 2&3: Medium sensitivity. Shut off: Low sensitivity. 3. LED Jumper: This jumper simply enables/diables the on board LED and does not affect the operation of the sensor itself. If the application calls for it you can conceal the detection indication by disabling the LED. Short 1&2: LED will trigger when motion is detected. Short 2&3: LED will be off always Product Setup: Turning on power and LED indicator will be enabled regardless of the LED jumper settting so as to enable sensing activity confirmation during commissioning and maintenance. This lasts about 60 seconds after which the LED will be enabled or disabled depending on the LED jumper position. Notice 1. Please install and use the detector according to this manual, don t touch the surface of sensor to avoid affecting the sensitivity of the detector. Please shut off power and then clean the sensor by soft cloth with little alcohol if cleaning needed. 2. The product can reduce accident but may not perform as expected. The user is advised to take all necessary precautions for his/her safety and the protection of his/her property. 3. In order to ensure it can work normally, the power should be kept to supply and get on walking test periodically, once a week is better. - 6 -