Renewables High-Temperature Monobloc Air-t nobloc Air oc Air o t -Wat W er Heat P ater He umps er Heat Pum mps

Similar documents
61AF High-Temperature Monobloc Air-to-Water Heat Pumps with Integrated Hydronic Module. Nominal heating capacity kw.

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

38RBS Air-Cooled Condensing Units. Nominal cooling capacity: kw. Features. Easy and fast installation

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY

30RB /30RQ

30RB/RQ 039S-160S. Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: kw Nominal heating capacity: kw

30RB /30RQ

30RBY/RQY Ductable Air-Cooled Liquid Chillers/ Ductable Air-to-Water Heat Pumps PRO-DIALOG +

38RBS Air-Cooled Condensing Units. product selection data. commercial and industrial applications. compact design.

AR Ductable Air-Cooled Liquid Chillers Ductable Reversible Air-to-Water Heat Pumps

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

30RB Air-Cooled Liquid Chillers with Integrated Hydronic Module. Nominal cooling capacity kw. Easy and fast installation.

30RB A /30RQ

30RB Air-Cooled Liquid Chillers with Integrated Hydronic Module PRODUCT SELECTION DATA. Compact design

30RB Air-Cooled Liquid Chillers with Integrated Hydronic Module. Nominal cooling capacity kw. Easy and fast installation.

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

30RB/RQ Air-Cooled Liquid Chillers/Air-to-Water Heat Pumps. product selection data

30XA Air-Cooled Liquid Chillers. Nominal cooling capacity kw

30RH B Nominal cooling capacity kw Nominal heating capacity kw

Unit with optional hydronic module 61WG/30WG. Nominal cooling capacity kw Nominal heating capacity kw

30RB /30RQ

30RQV NEW. Nominal cooling capacity kw Nominal heating capacity kw AIR-TO-WATER HEAT PUMPS HEATING. Easy and fast installation

30XAS Air-Cooled Liquid Chillers PRO-DIALOG + Nominal cooling capacity kw. Features and advantages. Very economical operation

AQUASNAP JUNIOR 30RHV

30GK. Air-Cooled Liquid Chillers. Nominal cooling capacity kw

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

30GX - 50 Hz. Air-Cooled Screw Compressor Liquid Chillers GLOBAL CHILLER. Nominal cooling capacity kw

30RB/RQ Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump 30RB: Nominal cooling capacity: kw 30RQ: Nominal cooling capacity:

30XAS A Air-Cooled Liquid Chillers. Nominal cooling capacity kw 50 Hz. Features and advantages. Very economical operation

30RB/RQ Air-Cooled Liquid Chiller Reversible Air-to-Water Heat Pump

30RB/RQ 039S-160S Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump

30HXC - 50 HZ. Water-Cooled Screw Compressor Liquid Chillers. Nominal cooling capacity kw

AQUASNAP AIR CONDITIONING MADE SIMPLE 30RA/30RH AQUASNAP LIQUID CHILLERS HEAT PUMPS

30GX 50 Hz. Air-Cooled Screw Compressor Liquid Chillers GLOBAL CHILLER. Nominal cooling capacity kw

30KAV Variable Speed Air-cooled Screw Chiller

30RB Air-Cooled Liquid Chillers with Integrated Hydronic Module. Nominal cooling capacity kw. Easy and fast installation.

61WG/30WG/30WGA. Water-Cooled and Condenserless Liquid Chillers Water-Sourced Heat Pumps. product selection data. 30WG optimized for cooling

30HXC Nominal cooling capacity kw

30RB/RQ Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump 30RB: Nominal cooling capacity: 18.8~35.5 kw 30RQ: Nominal cooling

Carrier India. Snapshots of Carrier India manufacturing facility

30RBM/30RBP Air-Cooled Scroll Chillers with Greenspeed Intelligence PRODUCT SELECTION DATA. MAINTENANCE INSTRUCTIONS Low sound level

30RBS /30RQS Air-Cooled Liquid Chillers, Reversible Air-to-Water Heat Pumps. product selection data

30RB Air-Cooled Liquid Chillers PRO-DIALOG + Nominal cooling capacity kw. Features. Quiet operation

30RBV/30RQV Inverter Air-Cooled Liquid chillers & Reversible Air to Water Heat Pumps PRODUCT SELECTION DATA INSTALLATION, OPERATION AND

Compact and silent Scroll compressors All-season operation

DYNACIAT LG. Use. Range. Water chillers Heat pump. DYNACIAT LGN series. DYNACIAT LG series. Hydraulic module

H o t Wa te r Syste m s. Senator Electric Flow Boilers. Making Life Simpler

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Water and ground source heat pumps 61WG kw. Heating

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

EPCE00-10B. Powerful. air cooled. Hydronic systems EUWA*40-200K(A)X

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

30RBM/30RBP AIR-COOLED SCROLL CHILLERS WITH GREENSPEED INTELLIGENCE PRODUCT SELECTION DATA

Neosys Product catalogue

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

30RBM/30RBP Air-Cooled Scroll Chillers with Greenspeed Intelligence PRODUCT SELECTION DATA. MAINTENANCE INSTRUCTIONS Low sound level

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

LIQUID CHILLER HEAT PUMP kw 30RB/30RQ - R410A. A Multi-Talented Performer

HT V2 HT Split

30XA Air-Cooled Liquid Chillers. Nominal cooling capacity kw. Features and advantages. Very economical operation

AQUACIAT LD ILD. Use. Range. Water chillers Heat pump. AQUACIAT LD series. AQUACIAT ILD series. Heat recovery. Cooling only. Cooling and heating

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

30AW. Reversible Air to Water Heat Pump PRODUCT SELECTION DATA. Monobloc inverter. Compact, reliable and efficient. More than a Heat Pump

Do you want a versatile solution

30XW-V/30XWHV. Variable-Speed Water-Cooled Liquid Chillers/ Variable-Speed-Water-to-Water Heating Units

30RB B 30RB Air-Cooled Liquid Chillers. Nominal cooling capacity kw. 50 Hz

Condensing Units CUS 15-60

High temperature air-to-water heat pumps

DYNACIAT LG. Use. Range. Water chillers Heat pump. DYNACIAT LGN series. DYNACIAT LG series. Hydraulic module

NEOSYS. AIR TO WATER LIQUID CHILLER kw. AIR TO WATER HEAT PUMP kw. lennoxemea.com

30HX GLOBAL CHILLER LIQUID CHILLER IN HARMONY WITH THE ENVIRONMENT

Modular Air Cooled Scroll Chillers

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

HYDROCIAT LW. Use. Range. Water chillers Heat pump. Cooling capacity kw Heating capacity kw. HYDROCIAT LW, ST series

3 0 H X C A - H P 2

HYDROCIAT LW R407C. Water cooled chillers USE RANGE

61AF. High-temperature heat pumps. Nominal heating capacity kw. 50 Hz. Installation, operation and maintenance instructions

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

INSTALLATION, OPERATION AND M A I N T E N A N C E I N S T R U C T I O N S

61AF-A. High-temperature heat pumps PRO-DIALOG INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS. Nominal heating capacity kw 50 Hz

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

30XW-V/30XWHV. Variable-Speed Water-Cooled Liquid Chillers/ Variable-Speed-Water-to-Water Heating Units

30RB/RQ Modular Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

LZT High efficiency air to water heat pumps with E.V.I. compressors

SIMPLICITY OR FULL MODULARITY?

30RQ Reversible Air-to-Water Heat Pumps with Integrated Hydronic Module

DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: ,

Water-cooled chillers with High Speed Centrifugal Compressors

environmental climate control equipment & solutions AQUACOOL Water-to-water heat pump with passive energy recovery

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

AGEO CALEO. Water-to-water high temperature heat pumps USE RANGE DESCRIPTION. Designed to replace a conventional boiler and produce domestic hot water

Transcription:

Renewables High-Temperature Monobloc oc Air-to-Water r Heat Pumps

Commercial Heat Pumps When it comes to creating efficient and cost-effective energy solutions that address today s growing environmental concerns, Kingspan Renewables leads the way. As a division of Kingspan Group plc, a major player in the building products sector, Kingspan Renewables puts significant emphasis on energy conservation and the development of environmentally friendly solutions to generate hot water and home heating. Climate change is now a generally accepted fact, which has increased our focus on alternative energy sources that would help to reduce not only carbon emissions (being a significant contribution to global warming), but also energy bills. One of the most efficient and cost-effective renewable energy technologies currently available for domestic and commercial applications are air source heat pumps. Aeromax Plus Air Source Heat Pumps reflect our on-going commitment to a zero carbon lifestyle and a brighter future for us all. Whether you need a heat pump for a new building or a refurbishment project, Kingspan can offer you the total solutions package to meet your specific needs. Kingspan is unique in its approach to providing renewable energy technologies. Outstanding Benefits Accredited Installer Network Design Service Training Centre Service Team Simple Installation Install with Confidence

Why A Heat Pump? An air source heat pump collects and utilises thermal energy from the outside air to heat the home and provide domestic hot water. It does this in the same way that a fridge extracts heat from the contents inside. It can extract heat from the air even when the outside temperature is as low as -20 C, it then converts this for use in a heating and hot water system. The heat generated can be used to warm water for radiators, fan coil and underfloor heating systems or provide hot water in your building. The process is simple, effective and renewable; something which is good for both the environment and future generations as well as our pockets. Please visit the Kingspan website for accredited heat pump installers. Basic Concept of Heat Pump Technology Free from the air Generated by Electricty Heating 3

Commercial Heat Pumps The new generation of Aeromax Plus high-temperature heat pumps was designed for commercial applications such as the heating of offices, apartments and hotels as well as domestic hot water production in new and refurbished buildings. The main features of this product range are: - The high-temperature Aeromax Plus heat pumps incorporate a hydronic module with a multi-speed pump, as standard. An optional hydronic module with a variable-speed pump that automatically adapts to the system requirements is also available. - The low noise levels of the Aeromax Plus Commercial heat pump and its very compact chassis reduce the noise disturbance from the unit. - The operating range allows outside temperatures down to -20 C and leaving water temperatures up to 65 C for domestic hot water applications. - Intelligent unit control permits unit operation in extreme conditions, minimising unit shut-down times. - Hot water production at 65 C is available continuously. Kingspan s quality is your guarantee for the safety and durability of the installation. The new generation of high-temperature heat pumps incorporates the latest technological features: The high-temperature Aeromax Plus heat pumps can be equipped with a hydronic module that is integrated into the heat pump chassis, limiting the installation to straightforward operations like the wiring and the connection of the hot water supply and return piping. - Control algorithm prevents excessive compressor cycling and permits reduction of the water quantity in the hydronic circuit - Corrosion resistance tests in salt mist in the laboratory. - Accelerated ageing test on components that are submitted to continuous operation: compressor piping, fan supports. - Transport simulation test in the laboratory on a vibrating table. Environmental care - Chlorine-free refrigerant of the HFC group with zero ozone depletion potential. - Very efficient - ensures an increased energy efficiency ratio (COP). - Brazed refrigerant connections for increased leak-tightness. - Reduction of leaks due to elimination of capillary tubes (TXVs). - Verification of pressure transducers and temperature sensors without transferring refrigerant charge. 4

Easy and fast installation Quiet operation - Multi-speed centrifugal water pump, based on the pressure loss of the hydronic installation. - Water filter protects the water pump against circulating debris. - Pump protected against cavitation by a pressure transducer that measures the entering water pressure. - Overpressure valve, set to 4 bar. - Thermal insulation and frost protection down to -20 C, using an electric resistance heater (see table of options). - The unit has a small footprint and a low height (329 mm) allowing it to blend in with any architectural styles. - The unit is enclosed by easily removable panels, covering all components (except condensers and fans). - Single power supply point without neutral. - Main disconnect switch with high trip capacity. - Transformer for safe 24 V control circuit supply included. - Systematic factory operation test before shipment. - Quick-test function for step-by-step verification of the instruments, electrical components and motors. - Low-noise scroll compressors with low vibration level. - The compressor assembly is installed on an independent chassis and supported by antivibration mountings. - Dynamic suction and discharge piping supports, minimising vibration transmission - Vertical evaporator coils - Protection grilles on anti-vibration mountings to protect the heat exchanger against possible shocks. - Latest-generation low-noise Flying Bird fans, made of a composite material are now even quieter and do not generate intrusive low-frequency noise. - Rigid fan installation for reduced start-up noise. Economical operation - The exceptional energy efficiency level (COP) of the high-temperature Aeromax Plus heat pumps in the heating mode is the result of a long qualification and optimisation process. - The electronic expansion device (EXV) allows operation at a lower condensing pressure (COP optimisation). - Dynamic superheat management for better utilisation of the condenser surface. - Maintenance-free scroll compressors with vapour injection. - Advance+ control offers fast diagnosis of possible incidents and their history.

Advance+ Control Advance+ combines intelligence with operating simplicity. The control constantly monitors all machine parameters and precisely manages the operation of compressors, expansion devices, fans and of the condenser water pump for optimum energy efficiency. Energy management - Seven-day internal time schedule clock: permits unit on/off control and operation at a second set point. - Set point reset based on the outside air temperature or the return water temperature or on the water heat exchanger delta T. - Master/slave control of two heat pumps operating in parallel with operating time equalisation and automatic change-over in case of a unit fault (option). - Start/stop based on the outside air temperature. Ease-of-use Building Management Systems (BMS) The Aeromax Plus Commercial range has been specifically designed to allow easy connection to Building Management Systems (BMS). Including the following protocols: - JBus - BacNet - Lon Talk - The new backlighted LCD interface includes a manual control potentiometer to ensure legibility under any lighting conditions. - The information is displayed clearly in English, French,German, Italian and Spanish (for other languages please consult Kingspan Renewables). - The Advance+ navigation uses intuitive treestructure menus, similar to the Internet browsers. They are user-friendly and permit quick access to the principal operating parameters: number of compressors operating, suction/discharge pressure, compressor operating hours, set point, air temperature, entering/leaving water temperature. - As standard the unit includes a board for the control of a boiler and four electric resistance heater stages. 6

Remote operating mode with volt-free contacts (standard) A simple two-wire communication bus between the RS485 port of the Aeromax Plus high-temperature heat pumps and the Kingspan Renewables Comfort Network offers multiple remote control, monitoring and diagnostic possibilities. Remote interface (accessory) This accessory includes a box that can be mounted inside the building. The power supply is provided via a 220 V/24 V transformer supplied. This interface allows access to the same menus as the unit interface and can be installed up to 300 m from the Aeromax Plus Commercial unit. Kingspan Renewables offers a vast choice of control products, specially designed to control, manage and supervise the operation of a heating system. Please consult your Kingspan Renewables representative for more information on these products. - Start/stop: opening of this contact will shut down the heat pump. - Dual set point: closing of this contact activates a second heating set point (example: unoccupied mode). - Demand limit: closing of this contact limits the maximum heat pump capacity to a predefined value. - User safety: this contact is connected in series with the water flow switch and can be used for any customer safety loop. - Water pump control. - Alert indication: this volt-free contact indicates the presence of a minor fault. - Alarm indication: this volt-free contact indicates the presence of a major fault that has led to the shut-down of the refrigerant circuit.

Options & Accessories Options & Accessories Options No. Description Advantages Use Anti-corrosion protection, traditional coils 3A Fins made of pre-treated aluminium (polyurethane or epoxy) Improved corrosion resistance, recommended for marine environments 22 kw-05 kw Low noise level 5 Acoustic compressor enclosure Noise emission reduction 22 kw-05 kw Low noise level 5LS Acoustic compressor enclosure and fan speed reduction, when ambient air temperature is above 20 C. Noise emission reduction 22 kw-05 kw Soft starter 25 Electronic compressor starter Reduced compressor start-up current 22 kw-05 kw Frost protection down to -20 C 42 Electric heater on the hydronic module (option 6) Low-pressure single-pump hydronic module JBus gateway 48B Two-directional communications board, complies with JBus protocol BacNet gateway 48C Two-directional communications board, complies with BacNet protocol LonTalk gateway 48D Two-directional communications board, complies with LonTalk protocol Heating system control* 57 Additional remotely installed control box, allows control of the various heating system components Hydronic module frost protection at low outside temperature 22 kw-05 kw with option 6F 6F See hydronic module chapter Easy and fast installation 022 kw-05 kw Easy connection by communication bus to a building management system Easy connection by communication bus to a building management system Easy connection by communication bus to a building management system Allows control of pre-configured heating systems 022 kw-05 kw 22 kw-05 kw 22 kw-05 kw 22 kw-05 kw Accessories Description Advantages Use Remote user interface Remotely installed user interface (via Remote heat pump control up to 300 m 22 kw-05 kw communication bus). JBus gateway communication Two-directional communications board, complies with JBus protocol Connection by communication bus to a building management system 22 kw-05 kw BacNet gateway communication LonTalk gateway communication Twinning (lead-lag kit) * Option available in 20. Two-directional communications board, complies with BacNet protocol Two-directional communications board, complies with LonTalk protocol Unit equipped with an additional field-installed leaving water temperature sensor, allowing master/slave operation of two units connected in parallel Connection by communication bus to a building management system Connection by communication bus to a building management system Operation of two units connected in parallel with operating time equalisation 22 kw-05 kw 22 kw-05 kw 22 kw-05 kw located immediately upstream of the main disconnect switch. - a main disconnect switch, - starter and motor protection devices for the compressor, the fan and the pump, - the control devices. All connections to the system and the electrical installations must be in full accordance with all applicable local codes. conformance with these codes. The recommendations of European standard EN 60204- (machine safety - electrical machine components - part : general regulations - corresponds to IEC 60204-) are specifically taken into account, when designing the electrical equipment. the requirements of the installation directives. Conformance with EN60204- is the best means of ensuring compliance with the Machinery Directive.5.. used for the operation of the machines. below:. Environment* - Environment as classified in EN 6072 (corresponds to IEC 6072): - outdoor installation* - ambient temperature range: -20 C to +40 C, class 4K4H - altitude: 2000 m - presence of hard solids, class 4S2 (no significant dust present) - presence of corrosive and polluting substances, class 4C2 (negligible) 2. Power supply frequency variation: ± 2 Hz. 3. The neutral (N) conductor must not be connected directly to the unit (if necessary use a transformer). 4. Overcurrent protection of the power supply conductors is not provided with the unit. 5. The factory-installed disconnect switch is of a type suitable for power interruption in accordance with EN 60947-3 (corresponds to IEC 60947-3) 6. The units are designed for connection to TN networks (IEC60364). For IT networks the earth connection must not be at the network earth. Provide a local earth, consult competent local organisations to complete the electrical installation. : If particular aspects of an actual installation do not conform to the conditions described above, or if there are other conditions which should be considered, always contact your local Kingspan Renewables representative. document IEC 60529). All Aeromax Plus Commercial units are protected to IP44CW and fulfil this protection condition. 8

Physical & electrical Data Physical data Nominal heating capacity* kw 20.8 25.7 32.2 43.6 52.2 66.7 02 Power input kw 5.8 7.3 9.2.8 4 9.4 28. Coefficient of performance (COP) kw/kw 3.6 3.5 3.5 3.7 3.7 3.4 3.6 Eurovent class, heating A A A A A A A Nominal heating capacity** kw 2.2 26. 32.8 43.8 52.8 64.7 02 Power input kw 4.9 6. 7.8 9.9.9 6. 23.6 Coefficient of performance (COP) kw/kw 4.3 4.3 4.2 4.4 4.4 4 4.3 Eurovent class, heating A A A A A B A Operating weight*** Standard unit (without hydronic kit) kg 343 396 42 509 533 900 020 Standard unit (plus hydronic module option) kg 349 403 436 524 549 926 046 Sound levels Sound power level 0-2 W**** db(a) 8 82 83 83 84 84 85 Sound pressure level at 0 m db(a) 50 5 5 5 53 52 53 Compressor Hermetic scroll 48.3 r/s Quantity 2 2 Number of capacity stages 2 2 Refrigerant R-407C Charge kg 8 8.8 9.7 0 3.2 22 26.5 Capacity control Pro-Dialog+ Minimum capacity % 00 00 00 00 00 50 50 Condenser Direct-expansion plate heat exchanger Water volume l 4.9 6.4 8.2 9.6 2. 6.4 22.7 Max. water-side operating pressure without hydronic module kpa Max. water-side operating pressure with hydronic module kpa 400 400 400 400 400 400 400 Fan Axial with rotating shroud, Flying Bird IV Quantity 2 2 Total air flow (high speed) l/s 3800 3800 3800 3800 3800 7600 7600 Speed r/s 2 2 2 2 2 2 2 Evaporator Grooved copper tubes and aluminium fins Hydronic module (option 6) Three-speed single pump Pump, Victaulic screen filter, safety valve, purge valves (water and air), cavitation presssure sensor Water connections with/without hydronic module Victaulic Connections inch ¼ ¼ ½ ½ ½ 2 2 Outside diameter mm 42.4 42.4 48.3 48.3 48.3 60.3 60.3 Chassis paint colour Colour code: RAL 7035 * Maximum instantaneous start-up current (maximum operating current of the compressor + fan current + locked rotor current of the compressor). ** Power input, compressor and fan, at the unit operating limits (saturated suction temperature 0 C, saturated condensing temperature 65 C) and nominal voltage of 400 V (data given on the unit nameplate). *** Standardised Eurovent conditions: condenser entering/leaving water temperature = 40 C/45 C, outside air temperature db/wb = 7 C/6 C. **** Maximum unit operating current at maximum unit power input and 400 V (values given on the unit nameplate). Maximum unit operating current at maximum unit power input and 360 V. Electrical data Power circuit Nominal power supply V-ph-Hz 400-3-50 Voltage range V 360-440 Control circuit supply 24 V, via internal transformer Maximum start-up current (Un)* Standard unit A 04.6 02.6 3 7 9 54.5 22.5 Unit with electronic starter option A 56. 55. 70 90.8 0.2 0.5 42.5 Unit power factor at maximum capacity** 0.82 0.82 0.82 0.82 0.82 0.82 0.82 Maximum unit power input** kw 8.7.6 2.9 4.6 6.8 25.8 33.7 Nominal unit current draw*** A 4.3 6.9 20.2 23.2 27.9 39.7 55. Maximum unit current draw (Un)**** A 6. 2.3 24. 27. 3. 47.5 6.5 Maximum unit current draw (Un-0%) A 2. 28.4 32.2 36.4 42 63.7 83.3 Customer-side unit power reserve Customer reserve at the 24 V control power circuit Short-circuit stability and protection See table on the next page * Maximum instantaneous start-up current (maximum operating current of the compressor + fan current + locked rotor current of the compressor). ** Power input, compressor and fan, at the unit operating limits (saturated suction temperature 0 C, saturated condensing temperature 65 C) and nominal voltage of 400 V (data given on the unit nameplate). *** Standardised Eurovent conditions: condenser entering/leaving water temperature = 40 C/45 C, outside air temperature db/wb = 7 C/6 C. **** Maximum unit operating current at maximum unit power input and 400 V (values given on the unit nameplate). Maximum unit operating current at maximum unit power input and 360 V. 9

Operating Limits Short-circuit stability current, main disconnect without fuse (TN system*) Short-term current at s (Icw) ka rms 0.6 0.6 0.6.26.26.26 2 Admissible peak current (Ipk) ka pk 4.5 4.5 4.5 6 6 6 0 Conditional short-circuit current (Icc) ka rms 5.4 7 7 7.7 7.7 6. 0 Siemens circuit breaker - Compact range 32 40 40 50 63 80 00 Reference number** 5SY6332-7 5SY6340-7 5SY6340-7 5SY4350-7 5SY4363-8 5SP4380-7 5SP439-7 Conditional short-circuit current (Icc) ka rms 7 50 50 50 50 4.5 22 Siemens fuse (gl/gg) 40 40 40 63 63 80 25 * Earthing system type ** If another current limitation protection system is used, its time-current and thermal constraint (I²t) trip characteristics must be at least equivalent to those of the recommended Siemens circuit breaker. Contact your nearest Kingpsan Renewables office. The short-circuit stability current values above are in accordance with the TN system. Operating range Condenser * Outside temperature: For transport and storage of the Aeromax Plus Commercial units the minimum and maximum allowable temperatures are -20 C and +50 C. It is recommended that these temperatures are used for transport by container. ** Refer to the minmum unit flow rate. Note: Do not exceed the maximum operating temperature. Minimum Maximum Entering water temperature at start-up C 8 57 Leaving water temperature during operation C 30 65 Entering/leaving water temperature difference K 3 ** Evaporator Entering air temperature* C -20 40 70 Plate heat exchanger water flow rate 0.4.6.8 0.5.7 2.4 0.7 3.3 3. 0.8 3.3 3.8 0.9 3.2 4.6.2 5.9 6.4.6 6. 8.5 * Maximum flow rate at an available pressure of 5 kpa. ** Maximum flow rate at a water temperature difference of 3 K in the plate heat exchanger. For a domestic hot water application (leaving water temperature = 65 C), the water temperature difference must be at least 8 K. 65 60 55 50 45 40 35 30 25 20-25 -20-5 -0-5 0 5 0 5 20 25 30 35 40 45

Dimensions & Clearances Aeromax Plus Commercial 022-035 units with and without hydronic module All dimensions are in mm 300 0 327 330 Required clearances for air flow Recommended space for maintenance Water inlet Water outlet Air outlet, do not obstruct Control box Power cable connection Aeromax Plus Commercial 045-055 units with and without hydronic module 4 200 300 330 Aeromax Plus Commercial 075-05 units with and without hydronic module 200 2273 330 2 2053 226 300 A Non-certified drawings. Refer to the certified dimensional drawings supplied with the unit or available on request, when designing an installation. For the location of fixing points, weight distribution and coordinates of the centre of gravity refer to the certified dimensional drawings. B In multiple-unit installations (maximum four units), the side clearance between the units should be increased from to 2000 mm. C The height of the solid surface must not exceed 2 m.

Heating Capacities Outdoor Air Temperature ( C) EWT-LWT Cap Unit COP Flow Dp Cap Unit COP Flow Dp Cap Unit COP Flow Dp Cap Unit COP Flow Dp Cap Unit COP Flow Dp Cap Unit COP Flow Dp Cap Unit COP Flow Dp C Kw kw l/s kpa kw kw l/s kpa kw kw l/s kpa kw kw l/s kpa kw kw l/s kpa kw kw l/s kpa kw kw ikw ikw ikw ikw ikw ikw ikw l/s kpa 25-30 0.2 4.8 2.3 0.49 2. 4.8 2.52 0.58 2 3.9 4.8 2.90 0.67 2 5.9 4.8 3.3 0.76 3 8 4.6 3.9 0.87 4 9 4.6 4.3 0.9 4 20.4 4.6 4.43 0.98 5 0. 5.7.77 0.58 3. 5.7 2.30 0.58 6 5.7 2.8 0.77 2 9 5.8 3.28 0.9 3 2.9 5.6 3.9.05 3 23.2 5.6 4.4. 4 25.2 5.7 4.42.2 4 5.6 6.6 2.36 0.75 8. 6.8 2.66 0.87 2 2 6.9 3.04.0 3 24.3 7 3.47.6 3 27.7 6.9 4.0.33 4 29.2 7 4.7.4 5 3.6 7 4.5.52 5 20 8.5 2.35 0.96 24.4 8.7 2.80.7 3 28.5 9 3.7.37 3 33. 9.2 3.60.59 5 38. 9. 4.9.83 6 40. 9. 4.4.93 6 4.3 9 4.59.98 7 25.6 9.4 2.72.23 2 29.9 0 2.99.43 3 34.5 0.4 3.32.66 4 39.8 0.7 3.72.9 5 45.3 0.8 4.9 2.7 6 47.5 0.8 4.40 2.28 6 50.3 0.9 4.6 2.42 7 32 4 2.29.54 2 37.6 4.4 2.6.8 3 43.8 4.7 2.98 2. 4 50.7 4.9 3.40 2.44 5 58.3 4.7 3.97 2.8 7 6.6 4.8 4.6 2.96 7 63. 4.8 4.26 3.03 8 47.6 9.3 2.47 2.29 4 54.9 9.9 2.76 2.64 5 64 20.4 3.4 3.08 6 74. 20.9 3.55 3.56 8 85.4 2.2 4.03 4. 90.2 2.2 4.25 4.33 2 97.6 2.7 4.50 4.69 4 30-35 9.8 5.2.88 0.47.8 5.2 2.27 0.57 2 3.9 5.2 2.67 0.67 2 5.8 5.2 3.04 0.76 3 7.9 4.9 3.65 0.86 3 8.8 4.9 3.84 0.9 4 20.2 4.9 4.2 0.97 4 0.2 5.9.73 0.49 3. 6 2.8 0.62 5.9 6 2.65 0.76 2 8.8 6. 3.08 0.9 3 2.7 6 3.62.04 3 22.9 6. 3.75. 4 24.8 6. 4.07.9 4 5.7 7. 2.2 0.76 8.2 7.3 2.49 0.87 2 20.9 7.5 2.79.0 2 24. 7.6 3.7.6 3 27.5 7.6 3.62.32 4 29 7.6 3.82.39 4 3.2 7.7 4.05.5 5 8.7 9. 2.05 0.89 23.4 9.3 2.52.2 3 28.2 9.6 2.94.36 3 32.7 9.8 3.34.57 4 37.6 9.8 3.84.8 6 39.6 9.8 4.04.9 6 4.8 9.8 4.27 2.0 7 25.6 0 2.56.23 2 29.8 0.6 2.8.43 3 34.4. 3.0.65 4 39.5.5 3.43.9 5 45.7 3.85 2.6 6 47.2.7 4.03 2.27 6 50.4.8 4.27 2.43 7 3.8 4.9 2.3.53 2 37.3 5.4 2.42.79 3 43.4 5.8 2.75 2.09 4 50.3 6. 3.2 2.42 5 57.8 6 3.6 2.78 6 6 6 3.8 2.93 7 63.8 6. 3.96 3.07 8 47.8 20.6 2.32 2.3 3 55. 2.4 2.57 2.65 5 63.9 22 2.90 3.07 6 73.9 22.6 3.27 3.55 8 84.9 22.9 3.7 4.09 0 89.7 23 3.90 4.3 2 97.2 23.4 4.5 4.67 3 35-40 0 5.5.82 0.48.9 5.5 2.6 0.57 2 3.9 5.5 2.53 0.67 2 5.7 5.6 2.80 0.76 3 7.8 5.3 3.36 0.86 3 8.6 5.3 3.5 0.9 4 20 5.3 3.77 0.96 4 0.4 6.2.68 0.5 3.2 6.3 2.0 0.63 5.9 6.4 2.48 0.76 2 8.7 6.6 2.83 0.9 2 2.5 6.5 3.3.03 3 22.7 6.5 3.49.09 4 24.6 6.6 3.73.8 4 5.9 7.7 2.06 0.77 8.3 7.9 2.32 0.88 2 2 8. 2.59.0 2 24 8.3 2.89.6 3 27.4 8.2 3.34.32 4 28.8 8.3 3.47.39 4 30.9 8.4 3.68.49 5 8.7 9.6.95 0.89 23.3 9.9 2.35. 3 28 0.2 2.75.35 3 32.3 0.5 3.08.56 4 37.2 0.6 3.5.79 5 39. 0.6 3.69.88 6 42. 0.7 3.93 2.03 7 25.7 0.6 2.42.24 2 29.8.3 2.64.44 3 34.3.9 2.88.65 3 39.3 2.3 3.20.89 4 44.7 2.6 3.55 2.6 6 46.9 2.6 3.72 2.26 6 50.2 2.8 3.92 2.42 7 3.7 5.9.99.53 2 37. 6.4 2.26.79 3 43.2 6.9 2.56 2.08 4 49.9 7.4 2.87 2.4 5 57.3 7.3 3.3 2.76 6 60.5 7.5 3.46 2.9 7 64.7 7.6 3.68 3.2 8 48. 22 2.9 2.32 3 55.4 23 2.4 2.67 5 64 23.8 2.69 3.08 6 73.8 24.5 3.0 3.56 8 84.7 24.9 3.40 4.08 0 89.4 25 3.58 4.3 96.8 25.4 3.8 4.66 3 40-45 0. 5.9.7 0.48 2 5.9 2.03 0.58 2 4 6 2.33 0.67 2 5.8 6 2.63 0.76 3 7.7 5.8 3.05 0.86 3 8.6 5.8 3.2 0.9 4 9.9 5.8 3.43 0.96 4 9.5 6.6.44 0.45 2.5 6.7.87 0.6 5.4 6.9 2.23 0.74 2 8.4 7.2 2.56 0.88 2 2.4 7. 3.0.03 3 22.5 7. 3.7.09 3 24.4 7.2 3.39.8 4 6. 8.3.94 0.78 8.5 8.6 2.5 0.89 2 2. 8.8 2.40.02 2 24 9 2.67.6 3 27.3 9 3.03.32 4 28.6 9 3.8.38 4 30.7 9. 3.37.48 5 9. 0.3.85 0.9 23.5 0.6 2.22.2 3 27.9 2.54.35 3 32..3 2.84.55 4 36.7.5 3.9.77 5 38.7.5 3.37.87 6 4.7.7 3.56 2.0 6 25.9.5 2.25.25 2 30 2.2 2.46.45 3 34.4 2.8 2.69.66 3 39.2 3.3 2.95.89 4 44.6 3.6 3.28 2.5 5 46.7 3.6 3.43 2.25 6 50 3.9 3.60 2.4 7 3.7 7.86.53 2 37. 7.6 2..79 3 43 8.2 2.36 2.08 4 49.7 8.8 2.64 2.4 5 57 8.8 3.03 2.75 6 60. 9 3.6 2.9 7 65 9.3 3.37 3.3 8 48.5 23.5 2.06 2.34 3 55.9 24.7 2.26 2.7 5 64.4 25.8 2.50 3. 6 74 26.7 2.77 3.57 8 84.8 27. 3.3 4.09 0 89.4 27.3 3.27 4.3 96.6 27.8 3.47 4.66 3 45-50 0.4 6.3.65 0.5 2.2 6.4.9 0.58 2 4. 6.5 2.7 0.68 2 5.9 6.5 2.45 0.77 3 7.8 6.4 2.78 0.86 3 8.6 6.4 2.9 0.9 4 9.9 6.4 3. 0.96 4 9.3 7..3 0.44 2.3 7.3.68 0.59 5.3 7.4 2.07 0.73 2 8.3 7.8 2.35 0.88 2 2.4 7.7 2.78.03 3 22.5 7.8 2.88.09 3 24.3 7.9 3.08.7 4 5.9 9.77 0.76 8.7 9.3 2.0 0.9 2 2.2 9.5 2.23.03 2 24. 9.7 2.48.6 3 27.2 9.7 2.80.32 4 28.6 9.8 2.92.38 4 30.6 0 3.06.48 5 7..53 0.8 2.8.5.90.04 3 28.9 2.35.35 3 32 2.3 2.60.55 4 36.5 2.4 2.94.76 5 38.4 2.6 3.05.86 5 4.3 2.7 3.25 2 6 25.8 2.7 2.03.23 2 30.4 3.3 2.29.47 3 34.7 3.9 2.50.67 3 39.3 4.3 2.75.9 4 44.5 4.7 3.03 2.5 5 46.7 4.8 3.6 2.26 6 49.8 5 3.32 2.4 6 3.8 8..76.54 2 37. 8.9.96.79 3 43. 9.7 2.9 2.08 4 49.6 20.3 2.44 2.4 5 56.8 20.5 2.77 2.75 6 59.9 20.7 2.89 2.89 7 64.7 2. 3.07 3.3 8 49 25.96 2.37 3 56.6 26.6 2.3 2.73 5 64.9 27.9 2.33 3.4 6 74.5 29 2.57 3.6 8 85 29.7 2.86 4. 0 89.6 29.9 3.00 4.33 96.8 30.4 3.8 4.67 3 50-55 0.7 6.8.57 0.5 2.5 6.9.8 0.6 2 4.3 7 2.04 0.69 2 6. 7. 2.27 0.78 3 8 7 2.57 0.87 3 8.7 7 2.67 0.9 4 9.9 7 2.84 0.97 4 0.5 7.6.38 0.5 3.2 7.9.67 0.63 6 8..98 0.76 2 8.8 8.5 2.2 0.9 2 2.5 8.5 2.53.04 3 22.6 8.6 2.63.09 3 24.3 8.7 2.79.8 4 6.3 9.7.68 0.78 8.9 0.89 0.92 2 2.4 0.3 2.08.04 2 24.2 0.5 2.30.7 3 27.2 0.6 2.57.32 4 28.6 0.7 2.67.38 4 30.5 0.9 2.80.48 4 8.9 2..56 0.9 23.3 2.5.86. 3 27.7 2.8 2.6.32 3 32. 3.3 2.4.55 4 36.4 3.6 2.68.76 5 38.2 3.7 2.79.85 5 4. 3.9 2.96.99 6 26.6 4..89.27 2 3 4.6 2.2.5 3 35. 5.2 2.3.7 3 39.6 5.6 2.54.92 4 44.6 6 2.79 2.6 5 46.7 6. 2.90 2.26 6 49.8 6.4 3.04 2.4 6 32 9.4.65.55 2 37.3 20.4.83.8 3 43.2 2.2 2.04 2.09 4 49.7 22 2.26 2.4 5 56.8 22.3 2.55 2.75 6 59.8 22.6 2.65 2.9 6 64.6 23 2.8 3.3 7 49.7 26.7.86 2.4 3 57.5 28.7 2.00 2.78 5 65.7 30.3 2.7 3.8 6 75.3 3.7 2.38 3.65 8 85.7 32.6 2.63 4.5 0 90. 32.9 2.74 4.36 97.2 33.5 2.90 4.7 2 55-65 - - - - - - - - - - 4.9 8.3.80 0.36 6.7 8.5.96 0.4 8.5 8.4 2.20 0.45 9.2 8.5 2.26 0.47 20.4 8.5 2.40 0.49 - - - - - - - - - - 6.6 9.6.73 0.4 9.2 0.2.88 0.46 2.9 0.2 2.5 0.52 23 0.3 2.23 0.56 24.6 0.5 2.34 0.6 - - - - - - - - - - 20.9 2..73 0.5 24. 2.4.94 0.58 27.3 2.4 2.20 0.65 28.6 2.5 2.29 0.7 30.6 2.7 2.4 0.74 - - - - - - - - - - 28.7 5.3.88 0.68 32.7 5.9 2.06 0.79 36.6 6. 2.27 0.89 38.4 6.3 2.36 0.93 4. 6.6 2.48 2 - - - - - - - - - - 36.6 8.4.99 0.89 40.2 8.7 2.5 0.96 45.2 9. 2.37.08 47.2 9.2 2.46.5 2 50.3 9.5 2.58.22 2 - - - - - - - - - - 43.9 24.3.8.07 50.3 25.2 2.00.22 57.2 25.7 2.23.39 2 60.2 26 2.32.46 2 64.8 26.5 2.45.57 2 - - - - - - - - - - 67.7 34.6.96.64 2 77.2 36.4 2.2.87 2 87.5 37.5 2.33 2.2 3 9.9 37.9 2.42 2.23 3 98.6 38.6 2.55 2.39 3 Leaving water temperature Entering water temperature Heating capacity Unit power input Condenser water flow rate Condenser pressure drop Standard units, refrigerant R407C Condenser entering/leaving water temperature difference: 5 K for EWT < 55 C Condenser entering/leaving water temperature difference: 0 K for EWT 55 C Condenser fluid: water Relative humidity: 87% Fouling factor: 0 (m2 K)/W - 0.8 x0-4 (m2 K)/W Performances in accordance with EN 45

Heating Capacities Outdoor Air Temperature ( C) 7 0 5 20 25 30 35 EWT-LWT Cap Unit COP Flow Dp Cap Unit COP Flow Dp Cap Unit COP Flow Dp Cap Unit COP Flow Dp Cap Unit COP Flow Dp Cap Unit COP Flow Dp Cap Unit COP Flow Dp C Kw kw l/s kpa kw kw l/s kpa kw kw l/s kpa kw kw l/s kpa kw kw l/s kpa kw kw l/s kpa kw kw ikw ikw ikw ikw ikw ikw ikw l/s kpa 25-30 2.5 4.6 4.67.03 5 23 4.6 5.00. 6 23.2 4.6 5.04. 6 23.2 4.6 5.04. 6 23.2 4.5 5.6. 6 23.2 4.5 5.6. 6 23.2 4.5 5.6. 6 26.5 5.7 4.65.27 5 28.6 5.7 5.02.37 6 32. 5.7 5.63.54 7 35.3 5.6 6.30.7 8 38.7 5.9 6.56.85 0 42. 5.7 7.39 2.0 2 42. 5.7 7.39 2.0 2 33.3 7. 4.69.6 6 36 7.2 5.00.73 7 40.4 7.3 5.53.94 8 38.2 7.4 5.6.83 7 39.6 7.5 5.28.89 8 4.8 7.6 5.50 2 9 4.8 7.6 5.50 2 9 42.8 9. 4.70 2.04 7 44.6 9. 4.90 2.3 8 47.8 9.2 5.20 2.28 9 50.9 9.3 5.47 2.43 0 54 9.4 5.74 2.58 57. 9.5 6.0 2.73 3 57. 9.5 6.0 2.73 3 5.4 0.9 4.72 2.47 7 52.4 0.9 4.8 2.5 8 55. 5.0 2.63 8 58.9. 5.3 2.8 0 62.7.2 5.60 2.99 66.5.3 5.88 3.8 2 66.5.3 5.88 3.8 2 64. 4.8 4.33 3.08 8 66.2 4.8 4.47 3.8 9 69.7 4.8 4.7 3.35 9 73.3 4.9 4.92 3.52 0 76.9 4.9 5.6 3.7 80.6 4.9 5.4 3.87 2 84.3 4.9 5.66 4.05 3 02 2.9 4.66 4.9 5 09 22.3 4.89 5.23 7 2 23.2 5.22 5.8 2 23 23.3 5.28 5.92 22 26 23.4 5.38 6.03 22 28 23.6 5.42 6.4 23 30 23.7 5.49 6.25 24 30-35 2.2 4.9 4.33.02 5 22.8 4.9 4.65.09 5 23.5 4.9 4.80.3 6 23.5 4.9 4.80.3 6 23.5 4.9 4.80.3 6 23.5 4.9 4.80.3 6 23.5 4.9 4.80.3 6 26. 6. 4.28.26 5 28. 6. 4.6.35 5 3.7 6.2 5..53 7 34.9 6.2 5.63.68 8 38.4 6.4 6.00.84 0 4.8 6.5 6.43 2 4.8 6.5 6.43 2 32.8 7.7 4.26.58 6 35.4 7.8 4.54.7 6 39.8 8 4.98.92 8 42.9 8. 5.30 2.05 9 46.2 8.3 5.57 2.2 0 50.4 8.4 6.00 2.4 2 50.4 8.4 6.00 2.4 2 43.6 9.9 4.40 2.08 7 46. 9.9 4.66 2.2 8 50.2 0. 4.97 2.4 0 54.4 0.2 5.33 2.6 58.6 0.3 5.69 2.8 3 62.8 0.4 6.04 3 5 62.8 0.4 6.04 3 5 5.9.9 4.36 2.49 7 53.2 2 4.43 2.54 8 56.7 2.2 4.65 2.7 9 6.2 2.3 4.98 2.92 0 65.7 2.5 5.26 3.4 2 70.2 2.7 5.53 3.35 3 70.2 2.7 5.53 3.35 3 64.7 6. 4.02 3. 8 66.7 6.2 4.2 3.2 8 70. 6.2 4.33 3.37 9 73.7 6.3 4.52 3.55 0 77.3 6.3 4.74 3.72 8 6.4 4.94 3.9 2 84.7 6.4 5.6 4.07 3 02 23.6 4.32 4.89 5 08 24 4.50 5.2 6 20 24.8 4.84 5.76 20 24 25. 4.94 5.99 2 27 25.2 5.04 6. 22 29 25.3 5.0 6.2 23 3 25.5 5.4 6.32 24 35-40 20.9 5.3 3.94.0 5 22.5 5.4 4.7.08 5 23.9 5.4 4.43.5 6 23.9 5.3 4.5.5 6 23.9 5.3 4.5.5 6 23.9 5.3 4.5.5 6 23.9 5.3 4.5.5 6 25.9 6.7 3.87.25 4 27.8 6.7 4.5.34 5 3.3 6.8 4.60.5 6 34.6 6.8 5.09.67 8 38. 7. 5.37.82 9 4.5 7.2 5.76.98 4.5 7.2 5.76.98 32.5 8.5 3.82.56 5 35 8.6 4.07.68 6 39.3 8.7 4.52.9 7 42.3 8.9 4.75 2.02 8 45.5 9. 5.00 2.7 0 49.6 9.2 5.39 2.37 2 49.6 9.2 5.39 2.37 2 44. 0.8 4.08 2. 7 47 0.8 4.35 2.25 8 52 4.73 2.48 0 56.9. 5.3 2.72 2 6.9.2 5.53 2.96 4 66.9.3 5.92 3.9 7 66.9.3 5.92 3.9 7 52 2.9 4.03 2.5 7 53.5 3. 4.08 2.56 8 57.3 3.3 4.3 2.74 9 62.2 3.6 4.57 2.97 0 67. 3.8 4.86 3.2 2 72 4. 5. 3.44 4 72 4. 5. 3.44 4 65.6 7.7 3.7 3.6 8 67.3 7.7 3.80 3.24 8 70.8 7.8 3.98 3.4 9 74.3 7.9 4.5 3.58 0 77.8 8 4.32 3.75 8.5 8 4.53 3.93 2 85.2 8. 4.7 4. 3 02 25.7 3.97 4.9 4 08 26. 4.4 5.2 6 9 26.8 4.44 5.73 9 26 27.3 4.62 6.07 2 28 27.4 4.67 6.8 22 30 27.5 4.73 6.29 23 33 27.6 4.82 6.4 24 40-45 20.8 5.9 3.53 4 22.3 5.8 3.84.07 5 24.4 5.8 4.2.8 6 24.4 5.8 4.2.8 6 24.4 5.8 4.2.8 6 24.4 5.8 4.2.8 6 24.4 5.8 4.2.8 6 25.7 7.3 3.52.24 4 27.6 7.3 3.78.33 5 30.9 7.4 4.8.49 6 34.4 7.5 4.59.66 7 37.8 7.8 4.85.8 9 4.2 8 5.5.97 4.2 8 5.5.97 32.2 9.2 3.50.55 5 34.6 9.3 3.72.67 6 38.9 9.5 4.09.88 7 4.8 9.7 4.3 2 8 45 9.9 4.55 2.5 9 49 0. 4.85 2.34 49 0. 4.85 2.34 43.6.8 3.69 2.08 7 46.6.9 3.92 2.22 8 5.5 2. 4.26 2.46 0 56.4 2.3 4.59 2.69 2 6.3 2.5 4.90 2.93 4 66.2 2.7 5.2 3.6 6 66.2 2.7 5.2 3.6 6 52.2 4 3.73 2.52 7 53.8 4.2 3.79 2.57 8 58 4.5 4.00 2.77 9 63.2 4.9 4.24 3.02 0 68.4 5.2 4.50 3.27 2 73.7 5.6 4.72 3.52 4 73.7 5.6 4.72 3.52 4 66.7 9.4 3.44 3.22 8 68. 9.4 3.5 3.28 8 7.6 9.5 3.67 3.45 9 75. 9.7 3.8 3.62 0 78.6 9.8 3.97 3.79 82.2 9.9 4.3 3.97 2 85.9 20 4.30 4.4 3 02 28. 3.63 4.9 4 08 28.5 3.79 5.22 6 9 29.2 4.08 5.74 9 28 29.8 4.30 6.7 22 30 30 4.33 6.27 22 32 30. 4.39 6.38 23 35 30.2 4.47 6.49 24 45-50 20.8 6.4 3.25 4 22. 6.4 3.45.07 5 24.7 6.4 3.86.9 6 24.9 6.4 3.89.2 6 24.9 6.4 3.89.2 6 24.9 6.4 3.89.2 6 24.9 6.4 3.89.2 6 25.5 8 3.9.23 4 27.4 8. 3.38.33 5 30.7 8.2 3.74.49 6 34.3 8.4 4.08.66 7 37.6 8.7 4.32.8 9 4. 8.9 4.62.96 0 4. 8.9 4.62.96 0 32 0. 3.7.55 5 34.3 0.2 3.36.66 6 38.5 0.4 3.70.86 7 4.2 0.6 3.89.97 8 44.2 0.9 4.06 2. 9 48.. 4.33 2.3 48.. 4.33 2.3 43.3 2.8 3.38 2.07 7 46.2 3 3.55 2.2 8 5. 3.3 3.84 2.44 9 55.9 3.6 4. 2.67 60.8 3.9 4.37 2.9 3 65.6 4. 4.65 3.4 5 65.6 4. 4.65 3.4 5 52 5.2 3.42 2.5 7 53.6 5.4 3.48 2.56 7 57.5 5.8 3.64 2.75 8 62.6 6.2 3.86 2.99 0 67.7 6.6 4.08 3.23 2 72.8 6.9 4.3 3.48 3 72.8 6.9 4.3 3.48 3 67.8 2.3 3.8 3.28 8 69.3 2.3 3.25 3.35 9 72.5 2.5 3.37 3.5 9 76. 2.7 3.5 3.68 0 79.6 2.8 3.65 3.85 83.2 22 3.78 4.02 2 86.9 22. 3.93 4.2 3 02 30.8 3.3 4.92 4 09 3.3 3.48 5.25 6 20 32. 3.74 5.77 9 30 32.8 3.96 6.29 22 32 33 4.00 6.4 23 35 33. 4.08 6.5 23 37 33.3 4. 6.62 24 50-55 20.8 7. 2.93.0 4 22. 7. 3..07 5 24.5 7. 3.45.9 6 25.6 7. 3.6.24 6 25.6 7. 3.6.24 6 25.6 7. 3.6.24 6 25.6 7 3.66.24 6 25.5 8.8 2.90.23 4 27.4 8.9 3.08.33 5 30.6 9. 3.36.48 6 34. 9.3 3.67.65 7 37.3 9.6 3.89.78 8 40.7 9.9 4..94 0 40.7 9.9 4..94 0 3.9 2.90.55 5 34.. 3.07.65 5 38..4 3.34.84 7 40.6.6 3.50.94 7 43.5.8 3.69 2.08 8 47. 2. 3.89 2.25 0 47. 2. 3.89 2.25 0 43. 4. 3.06 2.06 6 45.9 4.3 3.2 2.9 7 50.7 4.6 3.47 2.42 9 55.5 5 3.70 2.65 60.3 5.3 3.94 2.88 3 65 5.7 4.4 3. 5 65 5.7 4.4 3. 5 5.9 6.5 3.5 2.52 7 53.4 6.8 3.8 2.55 7 57.2 7.2 3.33 2.74 8 62.2 7.6 3.53 2.97 0 67. 8 3.73 3.2 72. 8.4 3.92 3.44 3 72. 8.4 3.92 3.44 3 67.9 23.3 2.9 3.29 8 70.8 23.5 3.0 3.43 9 73.7 23.7 3. 3.57 9 77.3 23.9 3.23 3.74 0 80.9 24.2 3.34 3.9 84.5 24.4 3.46 4.09 2 88. 24.6 3.58 4.27 3 02 33.9 3.0 4.94 4 0 34.5 3.9 5.3 6 20 35.4 3.39 5.82 9 32 36.3 3.64 6.37 22 35 36.5 3.70 6.55 23 38 36.7 3.76 6.66 24 40 36.9 3.79 6.77 25 55-65 2. 8.6 2.45 0.5 22.4 8.6 2.60 0.54 24.5 8.7 2.82 0.6 2 26.9 8.7 3.09 0.65 2 27. 8.7 3. 0.66 2 27. 8.7 3. 0.66 2 27. 8.7 3. 0.66 2 25.7 0.6 2.42 0.62 27.4 0.8 2.54 0.67 30.6. 2.76 0.74 2 33.8.3 2.99 0.82 2 37.7 3.6 0.88 2 40.2 2 3.35 0.96 3 40.2 2 3.35 0.96 3 3.8 2.9 2.47 0.77 33.9 3 2.6 0.82 2 37.4 3.3 2.8 0.9 2 39.7 3.6 2.92 0.95 2 42.2 4 3.0.0 2 45.5 4.3 3.8.09 3 45.5 4.3 3.8.09 3 42.8 6.8 2.55.02 2 45.5 7 2.68.09 2 49.9 7.5 2.85.9 2 54.3 7.9 3.03.3 3 58.7 8.4 3.9.4 3 63. 8.8 3.36.5 4 63. 8.8 3.36.5 4 52.3 9.6 2.67.27 2 53.6 9.9 2.69.28 2 57.3 20.3 2.82.37 2 62. 20.7 3.00.48 3 66.9 2. 3.7.6 3 7.6 2.5 3.33.7 3 7.6 2.5 3.33.7 3 68 26.8 2.54.65 2 73. 27.2 2.69.77 2 75.8 27.4 2.77.84 3 79.4 27.6 2.88.93 3 83 27.9 2.97 2.0 3 86.6 28. 3.08 2. 3 90.2 28.3 3.9 2.9 4 03 39. 2.63 2.5 4 39.6 2.80 2.69 4 22 40.4 3.02 2.96 5 33 4.2 3.23 3.23 6 39 4.6 3.34 3.38 6 42 4.7 3.4 3.44 7 44 4.8 3.44 3.49 7 Leaving water temperature Entering water temperature Heating capacity Unit power input Condenser water flow rate Condenser pressure drop Standard units, refrigerant R407C Condenser entering/leaving water temperature difference: 5 K for EWT < 55 C Condenser entering/leaving water temperature difference: 0 K for EWT 55 C Condenser fluid: water Relative humidity: 87% Fouling factor: 0 (m2 K)/W - 0.8 x0-4 (m2 K)/W Performances in accordance with EN 45 3

Hydronic Module The hydronic module option reduces the installation time. The heat pump is factory-equipped with the main hydronic components required for the installation: screen filter, water pump, safety valve, water pressure transducer, flow switch. The Advance+ control allows integration of system and water pump protection devices (insufficient water flow rate, water pressure, water flow rate etc.). The pump supplied with the hydronic module is a multispeed pump. An automatic pump start-up algorithm protects the heat exchanger and the hydronic module piping against frost down to -0 C outside air temperature, as standard. If necessary, increased frost protection down to -20 C is possible by adding heaters to the hydronic module piping (see option 42). The hydronic module option is integrated into the heat pump without increasing its dimensions and saves the space normally used for the water pump. Hydronic module Physical and electrical data, units with hydronic module Victaulic screen filter 2 Pressure sensor Note: Gives pump suction pressure information (see installation manual) 3 Safety valve 4 Water drain valve 5 Shut-off valve 6 Water pump 7 Temperature sensors, BPHE inlet Note: Gives heat exchanger entering temperature information (see installation manual) 8 Pressure gauge Note: Allows measuring of the pump suction pressure, the pump leaving pressure and the heat exchanger leaving pressure 9 Temperature sensor, BPHE outlet Note: Gives heat exchanger leaving temperature information (see installation manual) 0 Automatic air vent Flow switch 2 Plate heat exchanger frost protection heater 3 Plate heat exchanger 4 Temperature probe well 5 Air vent 6 Flexible connection 7 Shut-off valve 8 Screen filter (obligatory for a unit without hydronic module) 9 Pressure gauge 20 Water flow control valve 2 Charge valve 22 Frost protection bypass valve (when shut-off valves [7] are closed during winter) --- Hydronic module (unit with hydronic module) (standard units) are equipped with a flow switch and two temperature sensors (7 and 9). module, the pressure sensor located upstream of the pump to prevent cavitation is installed on a connection without Schraeder valves. Depressurise and drain the system before any intervention. Unit with hydronic module kg 349 403 436 524 549 926 044 Maximum operating pressure kpa 400 400 400 400 400 400 400 Water filter Victaulic screen filter Water pump TOP-S 25 TOP-S 25 TOP-S40 TOP-S40 TOP-S40 TOP-S50 TOP-S50 Shaft power input kw 0.8 0.8 0.35 0.35 0.35 0.45 0.45 Power input** kw 0.42 0.42 0.63 0.63 0.63 0.95 0.95 Nominal operating current draw A 0.4 0.4 0.6 0.6 0.7.3.5 Maximum current draw at 400 V*** A 0.8 0.8.3.3.3.7.7 Connections inch -/4 -/4 -/2 -/2 -/2 2 2 Outside diameter mm 42.4 42.4 48.3 48.3 48.3 60.3 60.3 * Weight shown is a guideline only. To find out the unit refrigerant charge, please refer to the unit nameplate. ** To obtain the maximum power input for a unit with hydronic module, add the maximum unit power input to the pump power input. *** To obtain the maximum operating current draw for a unit with hydronic module, add the maximum unit current draw to the pump current draw. 4 4 5 2 6 6 7 22 7 20 8 9 9 2 3 6 4 5 0 7 9 5 5 4 4 8 3 2 4

Available Static System Pressure Plate heat exchanger pressure drop - for pure water at 20 C Aeromax Plus Commercial 22 kw - 45 kw Aeromax Plus Commercial 55 kw -05 kw 30 50 Available pressure, kpa 25 20 5 0 2 3 4 Available pressure, kpa 40 30 20 2 3 5 0 0 0 2 3 4 5 22 kw 2 30 kw 3 35 kw 4 45 kw Water flow rate, l/s 0 0 2 4 6 8 0 55 kw 2 75 kw 3 05 kw Water flow rate, l/s

Available Static System Pressure Pump pressure/flow rate curves for units with hydronic module - for pure water at 20 C The Aeromax Plus Commercial units are equipped with a fixedspeed pump with three different speeds. These speeds can be manually adjusted by changing the speed terminal board inside the terminal box (this operation can only be carried out by approved personnel). The speed initially selected corresponds to standard use for heating water loops. If this speed needs to be changed, the pressure/flow curves for the three speeds are shown below. 22 0.4.8 30 0.5 2.4 35 0.7 3. 45 0.8 3.8 55 0.9 4.6 75. 6.4 05.5 8.5 * Maximum flow rate at a water temperature difference of 3 K in the plate heat exchanger (unit without hydronic module) Aeromax Plus Commercial 22 kw - 30 kw Aeromax Plus Commercial 35 kw - 55 kw 20 20 00 00 3 Available pressure, kpa Available pressure, kpa 80 3 60 40 2 20 0 0 0,2 0,4 0,6 0,8,0,2,4,6,8 2,0 22 kw-30 kw (speed ) 2 22 kw-30 kw (speed 2): selected 3 22 kw-30 kw (speed 3) 00 80 60 40 20 3 2 Water flow rate, l/s Aeromax Plus Commercial 75 kw -05 kw Available pressure, kpa 2 80 60 40 20 0 0 0,4 0,8,2,6 2,0 2,4 2,8 3,2 Water flow rate, l/s 35 kw-55 kw (speed ) 2 35 kw-55 kw (speed 2): selected 3 35 kw-55 kw (speed 3) 0 0 0,5,0,5 2,0 2,5 3,0 3,5 4,0 4,5 5,0 5,5 6,0 6,5 Water flow rate, l/s 75 kw-05 kw (speed ) 2 75 kw-05 kw (speed 2): selected 3 75 kw-05 kw (speed 3) 6

Available Static System Pressure Available system pressure for units with hydronic module - for pure water at 20 C The available pressure curves for the Aeromax Plus Commercial units are given for the speed initially selected. If the speed is changed by the user, the curves below do not apply. 22 0.4.6 30 0.5.7 35 0.7 3.3 45 0.8 3.3 55 0.9 3.2 75. 5.9 05.5 8.5 * Maximum flow rate at an available pressure of 5 kpa (unit with hydronic module). Aeromax Plus Commercial 22 kw - 30 kw Aeromax Plus Commercial 35 kw - 55 kw 00 00 Available pressure, kpa Available pressure, kpa 90 80 70 60 50 40 30 2 20 0 0 0,4 0,6 0,8,0,2,4,6,8 22 kw 2 30 kw Water flow rate, l/s Aeromax Plus Commercial 75 kw - 05 kw 00 80 60 40 2 20 Available pressure, kpa 80 60 40 3 20 2 0 0,5,0,5 2,0 2,5 3,0 3,5 35 kw 2 45 kw 3 55 kw Water flow rate, l/s 0 2 3 4 5 6 Water flow rate, l/s 75 kw 2 05 kw

Commerical Hot Water Products Kingspan Renewables Albion and Manchester Calorifiers divisions design and manufacture a large range of calorifiers specifically developed for commercial and industrial use. Kingspan Renewables Hot Water Systems division has a long history of trading in these products and over the years have been involved in many prestigious developments. The companies have supplied the hot water needs of customers as diverse as Shell, BBC, NatWest Bank, the Royal Courts of Justice, Horse Guard Barracks at Westminster as well as the supply of calorifiers to HM Prisons, schools, hotels, leisure centres, golf clubs - in fact wherever there is a demand for hot water, Kingspan Renewables are able to supply it. We also offer marine calorifiers and hot water provision for light commercial vehicles. We offer a full design service and are able to respond promptly to specifiers, contractors and engineers. Skilled operatives ensure that the final product meets the customer s specification. 8

We believe in providing our customers with a one-stop-shop for complete package solutions; from market-leading products, free initial advice, through to bespoke design, installation, final commissioning and technical support, allowing you to purchase with confidence. As a company committed to environmentally friendly energy solutions, we want to do everything we can to give homeowners confidence both in installing renewable energy technology and in the companies that install them. The Complete Package From Kingspan Coates Environmental & Renewable Design Partnership Professional design, planning and sizing is an important and inseparable factor when installing heat pumps into new properties or into existing dwellings, where the central heating and domestic hot water systems, already installed, are to work with the Aeromax Plus Air Source Heat Pump. That is why we don t confine our offer to simply selling the heat pump, but provide a complete service package, from initial advice and design, to training and technical support, making installation straightforward and stress-free. Renewable Energy Training Centre Sustainable energy systems have become an important area for the building services industry. Understanding how to provide these sources, systems and applications is seen as key in meeting the future needs of both commercial and domestic heating. We offer a range of courses that have been specifically desiged to provide experienced heating, plumbing, installation and building professionals with a real understanding of the potential for renewable energy sources, installation and their application. Our nationwide training courses offer an industry standard qualification which will help towards MCS accreditiation. Install with Confidence. With growing pressure to source alternative energy, reduce carbon emissions and cut energy bills, an increasing number of homeowners in the UK & Ireland are turning to renewable energy sources. To ensure that they receive the highest standards of conduct, workmanship and customer service, Kingspan has introduced a national network of accredited installers. To bring peace of mind to homeowners looking to install renewable hot water systems. To be accepted for the scheme, companies have to meet standards set out in a Code of Practice agreed by Kingspan Renewables. These include holding fully compliant British Plumbing Employers Council (BPEC or FETAC) qualifications, demonstrating their ability to do the job to the highest standard and ensuring excellent customer service before, during and after the system is installed. Field Service Team Our in-house field service team means that customers can rest assured that one-on-one support is available right across the country. The service team of highly qualified field-based engineers will bolster existing in-house support services with technical field support across the UK & Ireland. Fully trained to service the entire portfolio of Kingspan Renewable s products, the engineers will provide full technical back-up as well as being on hand to oversee installations and provide on-site training for installers. AeroServ SolarServ Serv 9

Guarantee The Aeromax Plus Heat Pump Package is designed for a long operational life. All components of the package carry a guarantee against faulty materials or manufacture: For the guarantee to be valid it is necessary that the system has been correctly installed in line with Installation Manual, Operating Instructions and all the relevant standards, regulations and codes of practice in force at the time. NuTech Renewables Ltd Unit, Wrrenpoint Enterprise Centre Newry Road, Warrenpoint Co.Down. BT34 3LA Tel: + 44 28 47 5303 Email: info@nutechrenewables.com www.nutechrenewables.com Kingspan Renewables have a policy of continuous product development and may introduce product modifications from time to time. As a consequence details given in this brochure are subject to alteration without notice. Kingspan Renewables Limited 80 Gilford Road, Portadown, Co. Armagh, Northern Ireland, BT63 5LF, United Kingdom. Tel: +44 (0) 28 3836 4500 Fax: +44 (0) 28 3836 450 E-mail: info@kingspansolar.com www.kingspansolar.com Kingspan Renewables Tadman Street, Wakefield, WF 5QU. Tel: +44 (0) 924 376 026 Fax: +44 (0) 924 385 05 GB only Tel: 0845 82 0007 Fax: 0845 82 0008 E-mail: sales@kingspan-renewables.com www.kingspan-renewables.co.uk Kingspan Renewables: A trading name of Kingspan Hot Water Systems Ltd. Registered Office: Tadman Street, Wakefield WF 5QU. Registered in England, No. 04357772 Issue 0April 20