STANDARD TECHNICAL SPECIFICATION FOR LEVEL SWITCH (FLOAT/DISPALCER TYPE) VOLUME - IIB. SPECIFICATION No: PES

Similar documents
STANDARD TECHNICAL SPECIFICATION FOR PRESSURE SWITCH, DIFFERENTIAL PRESSURE SWITCH VOLUME - IIB. SPECIFICATION No: PES

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirapalli , TAMIL NADU, INDIA MATERIALS MANAGEMENT / CAPITAL EQUIPMENT

CP1-C5 COMPACTOR SPECS 2009

TENDER DOCUMENT FOR SUPPLY OF EPOXY MIXING & POURING PLANT

NUCLEAR POWER CORPORATION OF INDIA LIMITED (A Government of India Enterprise)

Eligibility Criteria for Participation [Qualification Requirement (QR)]

SECTION STEAM CONDENSATE PUMPS

Scope of Work and Other Terms & Conditions

C. Shop Drawings: For boilers, boiler trim, and accessories. Include plans, elevations, sections, details, and attachments to other work.

Revitalize Building Mechanical Systems (4619)

Process Protection. MFA 4P Motion Failure Alarm

ADDENDUM NO. 1 COPPER COMMUNICATIONS CABLE AND VOICE AND DATA EQUIPMENT MONITORING, TESTING, AND REPAIR DEPARTMENT OF WATER RESOURCES

CALL FOR TENDER - MUNICIPALITY OF THE DISTRICT OF CLARE LITTLE BROOK, N.S.

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES

Annexure - 1. Detectors: Fire Alarm Control Panel :

Ultrasonic Point Level Switches

UW Purchase Specification Section Steam Condensate or Hot Water Meter Page 1 of 9

NPS/003/030 Technical Specification for Transformer and Switchgear Cable Boxes and their associated Bushing Assemblies

TITLE: SPECIFICATION NO. PE-MSE-VD-ACC VOLUME:

Ultrasonic Switches. Features & Benefits

38-SDMS-03 SPECIFICATIONS FOR LV DIGITAL PANEL METERS

38-SDMS-01 SPECIFICATIONS FOR FAULT INDICATORS FOR UNDERGROUND DISTRIBUTION NETWORKS

SECTION HEATING BOILER FEEDWATER EQUIPMENT

Replacement of Fire Pump and Generator Upgrade, H Building, Sexton Campus

SECTION AUTOMATIC TRANSFER SWITCHES

SECTION STEAM CONDENSATE PUMPS

Side Entry Insulation Damage Repair Sleeve (SEIDRS) Raychem Devices Products

Brooks MT3600 Series Metal Tube Variable Area Flowmeters

Page. 1-2 Sepra-Lite Integral Optic Level Switches. 3-5 Electro Optic Level Systems: Probe and Controller

SECTION PACKAGED COMPRESSOR AND CONDENSER UNITS

BuildingName The Description of the Project P DOCUMENTS

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.

PURCHASING SECTION th Street, Surrey, B.C. V3S 3C7 Tel: Fax: ADDENDUM NO.

TECHNICAL SPECIFICATION FOR SMC AMR METER BOXES MADE FROM THERMOSETTING PLASTIC

EG Controls. SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF E G

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA MATERIALS MANAGEMENT / CAPITAL EQUIPMENT

Time Extension: Tender submission deadline is extended up to 12:00 Hrs. of

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

THERMODYNAMIC STEAM TRAP

Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3

Dean Pump High Temperature Chemical Process Inline Pumps

SECTION GAS-FIRED RADIANT HEATERS

TEXAS DEPARTMENT OF TRANSPORTATION GENERAL SERVICES DIVISION LIGHT, WARNING, 360 DEGREE LED BEACON PUBLICATION

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA MATERIALS MANAGEMENT

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

BID PROPOSAL-REVISED

Building Name: Our Lady of Sorrows Date: July 10, 2013

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR PIPE THREAD IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

SECTION ELECTRICAL GENERAL PROVISIONS

BHARAT HEAVY ELECTRICAL LIMITED, JHANSI

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.

PT15 MATERIAL : DIMENSIONS - Nominal in inches. AVAILABLE SPARES: Disc (Packet of 5) ORDERING INFORMATION: Refer to "HOW TO ORDER" page.

TYPE POS Oil Shield Sump Pump

SECTION GENERATOR PARALLELING CONTROLS

.2 Section Waste Management and Disposal..5 Section Motors, Drives and Guards for Mechanical Systems.

Tubular Industrial Process

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

Survey of electrical equipment installed in hazardous areas on tankers

The Clark-Reliance Corporation TWIP System Installation and Maintenance Instructions - Form E112 -

ON THE BUTTON A reference guide to environmental ratings used for push button enclosures

Metal Tube Variable- Area Flow Meter (Series KM, KMS, KMSS)

PIP PCTPA001 Testing of Process Analyzer Systems

FS-100 Series OUTLINE MAIN APPLICATIONS FEATURES LEVEL SWITCH

STATEMENT OF WORK ELECTRICAL REPAIR / MAINTENANCE BUILDING PROJECT FDC RACCOON CREEK STATE PARK (BEAVER COUNTY)

NITROGEN-GENERATING SPRINKLER CORROSION INHIBITING SYSTEM

A19, A28 Series Thermostats for Agricultural Buildings

Ultra-Safe EXP Unit Heater

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

PART 3-O REQUIREMENTS FOR SPRINKLER SYSTEMS MAINTENANCE AND SUPERVISION. 3-O Introduction O.1 Scope of Maintenance and Supervision...

OPERATING AND MAINTENANCE MANUAL FOR ELECTRIC STAINLESS STEEL HEATER FOR DEIONIZED (DI) WATER ELECTRIC HEATER COMPANY BASE MODEL D

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2018

USER INSTRUCTIONS FOR FLANGE IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

Pipe Thread Heaters. Construction Features. Star Electric to Order Call " 2-1/2" Pipe Thread Heaters

A. AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) 101: Appendix Dissimilar Materials.

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

7.3 Design and Development Design and development planning Design and development inputs Design and development outputs 7.3.

SECTION WATER-TUBE BOILERS

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

PART GENERAL 1.01 SECTION INCLUDES

HORIZONTAL FIRE TUBE BOILERS Piping (HVAC) Pumping Equipment (HVAC).

Part: I TECHNICAL SPECIFICATION

Specification of (COC) Automatic Open Cup Flash Point Tester with accessories

COMMERCIAL ITEM DESCRIPTION TRAPS, STEAM

SECTION ELECTRIC-DRIVEN, FIRE PUMPS

SECTION AIR COILS

SPECIFICATIONS MODEL EHV X VACUUM OIL PURIFIER

SECTION AIR DOORS

SECTION AUTOMATIC TRANSFER SWITCHES

SECTION Fire Pumps

SUWANNEE RIVER WATER MANAGEMENT DISTRICT REQUEST FOR BID NO. 15/16-003AO FIRE ALARM SYSTEM INSTALLATION AND MONITORING.

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

Contact Phone Number: (609) Fax: (609)

SPECIFICATIONS MODEL E859C MINI DEHYDRATOR

GRUNDFOS SEWAGE & EFFLUENT PUMP ACCESSORIES

Transcription:

STANDARD TECHNICAL SPECIFICATION FOR LEVEL SWITCH (FLOAT/DISPALCER TYPE) - IIB SPECIFICATION No: PES-145-033 BHARAT HEAVY ELECTRICALS LIMITED POWER SECTOR PROJECT ENGINEERING MANAGEMENT DIVISION NOIDA, INDIA

SPECIFICATION FOR LEVEL SWITCH SPECIFICATION NO.: PES 145 033 II B D REV. NO. 01 DATE : 27.07.94 SHEET 1 OF 3 1.0 SCOPE This specification covers the Design, Manufacture, and Testing at the manufacturer s works, proper packing for transportation and delivery to site Level Switch (Float type/displacer type) for use in Utility/Captive Power Station/Combined Cycle Station. 2.0 CODES AND STANDARDS 2.1 All the equipments specified herein shall comply with the requirements the latest issue the relevant National and International s. 2.2 The Design and Materials used for the components shall also comply with the relevant National and International s. 3.0 TECHNICAL REQUIREMENTS 3.1 General The switches shall be magnetically operated, glandless type, suitable for tropical climate for operation at 0-55 C and Relative Humidity 0-95%. The switch shall be suitable for top mounting or side mounting with external chamber. 3.2 Housing The switch housing shall be die cast Aluminium/SS-304, weather pro, drain tight, water tight and dust tight as per NEMA 4. 3.3 Float Assembly/Displacer The float assembly/displacer shall be made stainless steel to AISI:316. Wire rope, spring housing, sleeve pipe shall also be AISI:316. 3.4 External Chamber The material for external chamber for side mounted level switches shall be as per data and shall be suitable thickness. A drain plug shall be provided in the external chamber to facilitate testing. The external chamber and the float assembly shall be arranged from the Level Switch supplier and not fabricated at site. 3.5 Mounting The switch shall be suitable for direct mounting on the vessel at top or side mounted on an external chamber connected to the vessel. 3.6 Switching Data The switch shall be single pole double throw (SPDT) or Double Pole Double Throw (DPDT) as specified in the data. The switch contacts shall be suitable for current rating 5A at 230V AC and 0.25A at 220V DC.

SPECIFICATION FOR LEVEL SWITCH SPECIFICATION NO.: PES 145 033 II B D REV. NO. 01 DATE : 27.07.94 SHEET 2 OF 3 3.7 Differential The differential between make and break shall be 12 ±2 mm for side mounted and 35 +3 mm for top mounted. Other adjustable range to suit the specific requirement shall also be acceptable. 3.8 Specific gravity the fluid Specific gravity the fluid shall be 0.7 to 1.2. 4.0 TESTING AND INSPECTION 4.1 The bidder shall adopt suitable quality assurance program to ensure that the equipments fered will meet the specification requirements in full. 4.2 The bidder shall furnish the Quality Plan in the format enclosed in volume-iii. In case the Quality Plan(s) is/are included in volume-iib, the bidder shall furnish his Quality Plan strictly in line with the same. The Quality Plan shall be discussed and finalised with the technically accepted bidders before opening the price bid. The stages where the purchaser would like to be associated for witnessing or verification would be indicated by the purchaser in the Quality Plan before approval. 4.3 The following test shall be conducted as a minimum requirement. a) Routine Tests i) Repeatability Test. ii) Contact Rating Test. b) Type Tests Weatherpro, water tight & dust tight test. 4.4 will be conducted by BHEL and/or their authorised representatives as per the agreed inspection schedule. The inspection schedule will be submitted by the bidder for BHEL s approval at contract stage. The cost all tests and inspections will be deemed to have been included in the bid. For all the type tests covered under 4.3 (b), Type Test Certificates as per agreed Quality Plan shall be furnished. In the absence the same, such Type Tests shall be arranged at the Vendor s works in the presence BHEL and/or their authorised representatives or in independent Test House /Laboratory approved by BHEL. 5.0 SPARES AND CONSUMABLES 5.1 Commissioning Spares The bidder shall supply all commissioning spares along with the equipment. 5.2 Recommended Spares The bidder shall furnish a list Recommended Spares along with the normal service expectancy period and frequency replacement; quantities recommended for 3 years operation along with unit rate against each item to enable BHEL/BHEL s Customer to place a separate order later, if required.

6.0 DRAWINGS AND DOCUMENTS SPECIFICATION FOR LEVEL SWITCH SPECIFICATION NO.: PES 145 033 II B D REV. NO. 01 DATE : 27.07.94 SHEET 3 OF 3 6.1 The bidder shall furnish the following documents in required number copies along with the bid: 6.1.1 Data -B, completely filled-up along with all enclosures. 6.1.2 Quality Plan. 6.1.3 Catalogs with detailed technical information. 6.1.4 Bar-chart to indicate the time schedule for procurement, manufacture, testing and despatch. 6.2 The successful bidder shall furnish the following documents in required number copies during the contract stage: 6.2.1 For approval i) Dimensional/Installation drawings. ii) Data -C, completely filled-up along with all the enclosures iii) Quality Plan vendor/sub-vendor. iv) Test Certificates. 6.2.2 Final/As-built Drawings Final/As-built drawings/rtfs in required number copies shall be submitted. 6.3 Operation & Maintenance Manuals O&M Manuals in required number copies shall be submitted. O&M Manuals shall also contain storage & commissioning instructions. 7.0 MARKING AND PACKING 7.1 Marking 7.2 Packing A stainless steel name-plate shall be permanently fixed on each equipment giving its Tag Number and technical specifications. All equipment/materials shall be suitably packed and protected for the entire period despatch, storage and erection against impact, abrasion, corrosion, incidental damage due to vermin, sunlight, high temperature, rain, moisture, humidity, dust, sea-water spray (where applicable) as well as rough handling and delays in transit and storage in open. 8.0 APPLICABLE DATA SHEET FORMS This document shall be read with one or more the following data forms : - Data A&B for Level Switch (Float/Displacer type) : Data no. PES-145-33-DS1-0 - Data C for Level Switch (Float/Displacer type) : Data no. PES-145-33-DS2-0

TAG No.. DATA SHEET FOR LEVEL SWITCHES (FLOAT / DISPLACER TYPE) SPECIFICATION NO.: REV. NO. DATE: SHEET 1 OF 1 Data Sheet No.: PES-145-33-DS1-0 Data Sheet A&B DESCRIPTION Data Sheet-A (To be filled in by Purchaser) Data Sheet-B (To be filled in by bidder) GENERAL MANUFACTURER MODEL NUMBER TOP MOUNTED TECHNICAL TYPE SIDE MOUNTED (with/without external chamber) DISPLACER TYPE FLOAT OPERATED EXTERNAL CHAMBER MATERIAL FLOAT ASSEMBLY SS ANSI 316 DISPLACER AISI 316 WIRE ROPE AISI 316 SLEEVE PIPE AISI 316 EXTERNAL CHAMBER SWITCH HOUSING GASKET ENCLOSURE TYPE OF SWITCH CS WELDED CONST. SS WELDED CONST. AS WELDED CONST. AISI 304 SS DIE C AST ALUMINIUM NEOPRENE TEFLON SWITCH HOUSING NEMA-4 FUEL GAS HAZARDOUS APPL. EXPL. PROOF SNAP ACTING MEGNETICALLY OPERATED CONTACT RATING YES CHAMBER DRAIN ½ NPT PLUG ISOLATION VALVE YES NO SP. GR. OF FLUID 0.70 TO 1.2 DIFF. BETWEEN MAKE & BREAK OF SWITCH 12 +2 mm (SIDE MOUNTED) 35 +3 mm (TOP MOUNTED) ADJUSTABLE MAXIMUM PRESSURE RATING MAXIMUM TEMPERATURE RATING PERFORMANCE REPEATABILITY +1mm CONNECTION EXT. CHAMBER CONNECTION 1 NB SOCKET WELD (TOP AND BOTTOM) ELECT. COMPLETE WITH CABLE GLAND TO SUIT CABLE WITH MAXIMUM 17.5mm O.D. ACCESSORIES INSTALLATION ACCESSORIES AS REQUIRED. NAME SIGNATURE DATE NAME SIGNATURE DATE

TAG No.. DATA SHEET FOR LEVEL SWITCHES (FLOAT / DISPLACER TYPE) SPECIFICATION NO.: REV. NO. DATE: SHEET 1 OF 1 Data Sheet No.: PES-145-33-DS2-0 Data Sheet C GENERAL TECHNICAL DESCRIPTION MANUFACTURER MODEL NUMBER TYPE MATERIAL DISPLACER WIRE ROPE SLEEVE PIPE EXTERNAL CHAMBER SWITCH HOUSING GASKET ENCLOSURE TYPE OF SWITCH CONTACT RATING ISOLATION VALVE SP. GR. OF FLUID Data -C (To be filled by the vendor after the award contact) DIFF. BETWEEN MAKE & BREAK OF SWITCH PERFORMANCE CONNECTION MAXIMUM PRESSURE RATING MAXIMUM TEMPERATURE RATING REPEATABILITY EXT. CHAMBER CONNECTION ELECT. ACCESSORIES NAME SIGNATURE DATE INSTALLATION ACCESSORIES NAME SIGNATURE DATE

PEM :: C&I Sl. No. Component / operation 1.0 Raw Material/ Component STANDARD QUALITY PLAN FOR LEVEL SWITCHES(FLOAT/DISPLACER TYPE) Characteristics ed * Cate gory Type/Method 1.1 Non Wetted Parts Physical, Chemical properties MA Physical, Chemical Analysis 1.2 Float Assembly & Wetted Parts Physical for float only & chemical properties for all wetted parts including float assembly MA Physical, Chemical Analysis Extent Reference documents 1/ Cast BHEL Spec/ Approved drg. / data 1/Batch AISI:316 / BHEL spec. / drg. / Acceptance Norms Relevant material QUALITY PLAN NO.: PE-QP-999-145-I033 AISI:316 / BHEL spec. / drg. / / Relevant material std. IIB D REV. NO. 00 DATE: 15.03.99 SHEET 1 OF 3 Format Records Agency $ P W V Remarks Test 3/2 --- 2,1* *Relevant compliance certificate to be verified. Test Certificate 3/2 --- 2,1* 1.3 Chamber Dimensions & leak tightness MA Measurement, visual, hyd. test 100% BHEL Spec/ Approved drg. / data BHEL Spec/ Approved drg. / data Internal inspection report 3/2 2 1 1.4 Float Leak tightness MA Hyd. test 100% BHEL Spec/ Approved drg. / data No leakage Internal inspection report 3/2 2 1 1.5 Switch 1.. Make, type and rating MA Visual 100% BHEL / Mfr. spec. BHEL / Mfr. spec. Internal inspection report 3/2 --- 2,1 2. Contact Continuity CR Electrical 100% BHEL / Mfr. spec. BHEL / Mfr. spec. To have continuity 3/2 --- 2,1 2.0 Final 2.1 Assembly 1. Marking: Range, Model, Tag No. Sl.No. MA Visual 100% 2 1 --- LEGEND: * CR - Critical characteristics $ P - Agency Performing the Test. 1 - BHEL MA - Major characteristics W - Agency Witnessing the Test. 2 - Vendor MI - Minor characteristics V - Agency Verifying the Test. 3 - Sub-vendor

PEM :: C&I Sl. No. Component / operation STANDARD QUALITY PLAN FOR LEVEL SWITCHES(FLOAT/DISPLACER TYPE) Characteristics ed 2. Correct assembly, workmanship and finish * Cate gory Type/Method Extent Reference documents MA Visual 100% Manufacturer Acceptance Norms Manufacturer QUALITY PLAN NO.: PE-QP-999-145-I033 IIB D REV. NO. 00 DATE: 15.03.99 SHEET 2 OF 3 Format Records Agency $ P W V Log Book 2 1 --- Remarks 3. Connection MA Visual & Measurement 100% 2 1 --- 4. Scale Marking MA Visual 100% 2 1 --- 5. Cleanliness MA Visual 100% Manufacturer Free from scratches dirt etc. Log Book 2 1 --- 6. Overall Dimension MA Measurement 100% Approved drg. Approved drg. 2 1 --- 2.2 Routine Test 1. Overload CR Measurement 100% 2. Repeatability CR Measurement 100% 3. Set point adjustment CR Measurement 100% Test 2 1 1 BHEL to witness 25% sample. Test 2 1 1 Test 2 1 1 LEGEND: * CR - Critical characteristics $ P - Agency Performing the Test. 1 - BHEL MA - Major characteristics W - Agency Witnessing the Test. 2 - Vendor MI - Minor characteristics V - Agency Verifying the Test. 3 - Sub-vendor

PEM :: C&I Sl. No. Component / operation STANDARD QUALITY PLAN FOR LEVEL SWITCHES(FLOAT/DISPLACER TYPE) Characteristics ed * Cate gory Type/Method Extent Reference documents 4, Differential CR Measurement 100% Acceptance Norms QUALITY PLAN NO.: PE-QP-999-145-I033 IIB D REV. NO. 00 DATE: 15.03.99 SHEET 3 OF 3 Format Records Agency $ P W V Test 2 1 1 Remarks 5. Contact Rating CR Measurement 100% 6. Insulation Resistance & HV CR Electrical 100% Manufacturer Manufacturer 2 --- 1 Manufacturer compliance certificate to be verified. Test 2 1 1 2.3 Type Test 1. Weatherproness CR Measurement 1 sample / design IS : 2147 / NEMA-4 Test 3/2 --- 1 Vendor to furnish test report 3.0 Packing Soundness packing MA Visual 100% BHEL Spec. BHEL Spec. Log Book 3/2 2 --- LEGEND: * CR - Critical characteristics $ P - Agency Performing the Test. 1 - BHEL MA - Major characteristics W - Agency Witnessing the Test. 2 - Vendor MI - Minor characteristics V - Agency Verifying the Test. 3 - Sub-vendor