Wireless DC Voltage Detector

Similar documents
VDC. Wireless AC Voltage Detection Sensor. The Leader in Low-Cost, Remote Monitoring Solutions. General Description. Monnit Sensor Core Specifications

VDC. The Leading Enterprise Internet of Things Solution. Wireless DC Voltage Detection Sensors (0-50 VDC) General Description

~500 V AC / DC. Wireless 500 VAC/VDC Voltage Meter. The Leader in Low-Cost, Remote Monitoring Solutions. Monnit Sensor Core Specifications

Wireless 0-5 Volt Meter Sensor

Wireless Light Detection Sensor

Wireless Thermocouple Sensor

Wireless Duct Temperature Sensor

The Leading Enterprise Internet of Things Solution. Wireless AC Voltage Detection Sensors ( VAC) VOLTAGE DETECT. General Description

The Leading Enterprise Internet of Things Solution. Wireless Open / Closed Sensors OPEN / CLOSED. Features of Monnit ALTA Sensors. General Description

The Leading Enterprise Internet of Things Solution. Wireless Dry Contact Sensors. General Description. Features of Monnit ALTA Sensors

Wireless Water Detection Sensors General Description Features of Monnit ALTA Sensors Water Detection Principle of Operation

The Leading Enterprise Internet of Things Solution. Wireless Thermocouple Sensors. General Description. Features of Monnit ALTA Sensors

The Leading Enterprise Internet of Things Solution. Wireless Duct Temperature Sensors. General Description. Features of Monnit ALTA Sensors

The Leading Enterprise Internet of Things Solution. Wireless 0-20 ma Current Meters. General Description. Features of Monnit ALTA Sensors

The Leading Enterprise Internet of Things Solution. Wireless Thermocouple Sensors. Features of Monnit ALTA Sensors. General Description

Frequently Asked Questions

Smart Monitoring Systems. for Property Management SMART SOLUTIONS. Property Management DOORS & WINDOWS TEMPERATURES LIGHTS CARBON MONOXIDE

FLOOD SERIES DATA SHEET

TotalPac X Single interlock SUREFIRE system

Photoelectric Beam Detector

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section CHLORINE GAS LEAK DETECTOR

TotalPac X Firecycle III Preaction Double interlock system

LIGHTNING PROTECTION SYSTEM

GasSens. Self Checking Gas Sensors. Modular Gas Detector... Gas & Range Availability

ON THE BUTTON A reference guide to environmental ratings used for push button enclosures

Temperature Monitoring, Operation and Maintenance of Research Freezers and Refrigerators SOP-TMOMRFR-01

XYZ XYZ XYZ XYZ XYZ XYZ. Energy Utility Based billing for Individual Tenants. Comprehensive Base Station Monitoring. Diesel Generator Monitoring


Q3200 Smart Home Alarm. Kit Content and Installation Guide

HOBO U30 Remote Monitoring Systems

Ion Gateway Cellular Gateway and Wireless Sensors

Ross SysCon Control Panels

Industrial Grade Gas Detection

Emergency Communications Tower Applications (Solar/Wireless/Surveillance)

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

IN A BOX. User Manual YOUR HOME SECURITY SYSTEM. curv360.co.uk. Support APP remote arm/disarm, parameter settings and accessories management

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

environmental chambers for Battery testing

DS500. Alarm Sensors (built in) Power. Sounds. Accessories* Attachment

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

Architectural and Engineering Specification for a. Flash / Flare


Architectural and Engineering Specification for a Real-Time Locating System Flare

ALTAIR 5X Multigas Detector

Quick Touch Pendant User Guide

Options for Diesel Fire Pump Controllers

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

DATAssure. Laboratory wireless alarm & monitoring system

Off-Grid CyboInverter Installation Guide. For CI-Mini-1200H Solar Mini-Inverter for Electric Water Heaters

Smart Wireless Sensor

Mobeye CM2410 GSM fire alarm communicator

STRIKE GUARD DELIVERS:

2G & 3G GSM Wireless Beam Alarm

Applications: 27. NETIChome mobile ios 28. NETIChome mobile Android. NETIChome basic elements

Gas Detection. - Disposable - Serviceable. Single Gas Detectors

Fiber Optic Cable Fence Disturbance Sensor

Operation and Maintenance Manual

Industrial Grade Gas Detection

G-TECTA TM. Portable Gas Detection Instruments

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

GLD-30 Gas Leak Detector

ELECTRICAL SAFETY Information Bulletin

Monitoring Solutions

WAVE SEQUENCER DELIVERS:

Product Catalogue. Complete Wireless Sensor Solutions SYSTEMS. 100% Peace of Mind! WEB ID WEB ID WEB ID

ALTAIR 5X Multigas Detector Product Specification

Explosion Proof Light Watt Metal Halide - Class 1 Div 1 & Class 2 Div 1

PIR Occupancy & Motion Sensor

Smart Wireless Sensor

Cold chain monitoring technologies. Facility monitoring

wireless. web-based. worthy of the name RACO.

Variable Frequency Drive SERIES MP800 VFD

Macurco HD-11 Hydrogen Gas Detector

D3 Wireless temperature alarm & monitoring system family. tek-troniks

Selecting an Electrical Enclosure

PRODUCT CATALOGUE. Cape Town 18 Darter Road Blue Water Estate Kommetjie. Gauteng 245 Louis Botha Avenue Orchards Johannesburg

RAPID Alert System User Guide. RAPID Alert System. User Guide

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Combustible and Toxic Gas Detection Solutions. Performance and Safety Beyond Compliance

The Standard In Safety

K100A Insertion Probe Thermometer

OUTDOOR 911 EMERGENCY COMMUNICATIONS

E/One Sentry Advisor

High Precision Digital Rain Gauge with Indoor Temperature and Humidity

RIG RAT III. Wireless Multi-Point Gas Detection System. The Stand-Alone Solution

DETECT-A-FIRE Heat Detectors

Gas Detection. Honeywell BW Solo. The next generation in portable single gas detection.

>WIRELESS> ALARM SYSTEM CR200

VENTIS PRO SERIES. Product Guide

THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY. 99 Washington Street Melrose, MA Phone Toll Free

ENCLOSURE COOLING. Glossary

Ammonia Detection System Codes and Design Specifications

Honeywell Temperature & Humidity Sensor with LCD

Instruction Manual. Self-Leveling Rotary Laser Level Model Nos and

100A / 200A. Maximum Heating Load: Enclosure Type: NEMA 4

Fall & Medical Alert Sensor

GLOBAL ENCLOSURE STANDARDS WITHIN THE ELECTRICAL INDUSTRY

SAFESITE Multi-Threat Detection System

Preliminary. SmarteLight v1.2 Manual. Revision: 1.0 Date: 12/4/2012. Revision: 1.0 Page i OmniSite

Transcription:

24-500 The Leader in Low-Cost, Remote Monitoring Solutions Wireless DC Voltage Detector VOLTAGE General Description Monnit s industrial wireless DC voltage detection sensor detects the presence or absence of electricity. It is intended for use on battery or other DC sources, up to 50 Volts. Not intended for use with AC Voltages. It is perfect for batteries, adapters, solar equipment, vehicles or machinery, and any other electrical appliance monitoring. The sensor triggers on voltage presence to voltage Absence and vice versa. The data is displayed as Voltage Detected or No Voltage. Detects presence or absence of voltage Voltage presence detected above ~.47 volts Voltage absence detected below ~.47 volts Detects voltages up to 50 volts Reverse voltage protection, up to 50 volts Principle of Operation Free imonnit basic online wireless sensor monitoring and notification system to configure sensors, view data and set alerts via SMS text and email. The Monnit industrial wireless DC voltage detection sensor detects the presence or absence of voltage. The sensor triggers on voltage presence to voltage absence and vice versa. The data is displayed as Voltage Detected or No Voltage. If no change is observed within the heartbeat interval, the state is continuously reported on the heartbeat interval. Transitions and heartbeat data is logged into a cloud service. The user can set the system to send an alert on either state, or on the transition of states. Monnit Sensor Core Specifications : 250-300 ft. (non line-of-sight / indoors / through walls, ceilings & floors) * Communication: RF 900, 920, 868 and 433 MHz Power: Replaceable batteries (optimized for long battery life) - Line-power (AA version) and solar (Industrial version) options available Battery Life (at 1 hour heartbeat setting) ** AA battery > 4-8 years Coin Cell > 2-3 years. Industrial > 4-8 years * Actual range may vary depending on environment. ** Battery life is determined by sensor reporting frequency and other variables. Example Interfacing Battery Power Relays/Switches Appliances Adapters Solar Power Supplies Sump Pumps And many more...

1.125 in (28.575 mm) 2.0 in (50.8 mm) 0.875 in (22.225 mm) Wireless DC Voltage Detector (Coin Cell) - Technical Specifications 2.0-3.6 Operating Temperature Range (Board Circuitry and Batteries) -7 C to +60 C (20 F to +140 F) * Optimal Battery Temperature Range (AA) +10 C to +50 C (+50 F to +122 F) 1.0 oz. Power Options Sensors are powered by a replaceable 3.0 V coin cell battery. Optional AA battery powered sensors are available. The AA version of these sensors are larger in size (3 [L] x 2.1 [W] x 1.2 [H] ) and include two longlife AA batteries. It is recommended that unless you are using the AA battery solution, you set heartbeat to no faster than one hour to preserve battery life. PinchPower Enclosure Pinch (press in on the sides) Pull (sensor away from base) _ CR2032 BATTERY + CR2032 BATTERY Press (sensor back into base) PAGE 2

2.470 4.375 1.111 3.295 1.111 Wireless DC Voltage Detector (AA) - Technical Specifications 2.0-3.6 (3.0-3.6 Using Power Supply) Operating Temperature Range (Board Circuitry and Batteries) -18 C to 55 C (0 F to 130 F) using alkaline -40 C to 85 C (-40 F to 185 F) using lithium * Optimal Battery Temperature Range (AA) +10 C to +50 C (+50 F to +122 F) 4.0 oz. Power Options Two replaceable 1.5V AA sized batteries are included with the standard model. A line-power version with battery backup is also available - allowing it to be powered by a standard 3.0-3.6V power supply and use the internal batteries if there is a power interruption. Power options must be selected at time of purchase as the internal hardware of the sensor must be changed to support the selected power requirements. PAGE 3

Industrial Wireless Sensor 2.316 in (58.84 mm) 3.701 in (94.0 mm) Height: 1.378 in (35.0 mm) Wireless DC Voltage Detector (Industrial) - Technical Specifications 2.0-3.6 Operating Temperature Range (Board Circuitry and Batteries) Included Battery Max Temperature Range: -40 C to +85 C (-40 F to +185 F) * Capacity: -40 C to +85 C (-40 F to +185 F) Optional Solar Feature Solar Panel: 1800 mah Charging Temperature Range: 5 / 30mA (53mm x 30mm) Max Temperature Range: 0 C to 45 C (32 F to 113 F) Included Rechargeable -20 C to 60 C (-4 F to 140 F) Battery: 5.0 oz. Enclosure Rating NEMA 1, 2, 4, 4x, 12 and 13 rated, sealed & weather proof UL Rating UL Listed to UL508-4x specifications (File E194432) PAGE 4

Notes: Commercial Grade Sensors Monnit commercial grade sensors are designed for applications in ordinary environments (normal room temperature, humidity and atmospheric pressure). Do not use these sensors under the following conditions as these factors can deteriorate the product characteristics and cause failures and burn-out. Corrosive gas or deoxidizing gas - chlorine gas, hydrogen sulfide gas, ammonia gas, sulfuric acid gas, nitric oxides gas, etc.) Volatile or flammable gas Dusty conditions Under low or high pressure Wet or excessively humid locations Places with salt water, oils chemical liquids or organic solvents Where there are excessively strong vibrations Other places where similar hazardous conditions exist Use these products within the specified temperature range. Higher temperature may cause deterioration of the characteristics or the material quality. Industrial Grade Sensors - Type 1, 2, 4, 4X, 12 and 13 NEMA Rated Enclosure Monnit s Industrial sensors are enclosed in reliable, weatherproof NEMA rated enclosures. Our NEMA rated enclosures are constructed for both indoor or outdoor use and protect the sensor circuitry against the ingress of solid foreign objects like dust as well as the damaging effects of water (rain, sleet, snow, splashing water, and hose directed water). Safe from falling dirt Protects against wind-blown dust Protects against rain, sleet, snow, splashing water, and hose directed water Increased level of corrosion resistance Will remain undamaged by ice formation on the enclosure For more information about our products or to place an order, please contact our sales department at 801-561-5555. Visit us on the web at www.monnit.com. Monnit Corporation 3400 South West Temple Salt Lake City, UT 84115 801-561-5555 www.monnit.com Monnit, imonnit and all other trademarks are property of Monnit, Corp. 2018 Monnit Corp. All Rights Reserved. MDS-044-1B (1/18)