D E F E N D E R Datacom Cabinets

Similar documents
SPECTRACOOL Indoor & Outdoor Air Conditioners

SPECTRACOOL Indoor & Outdoor Air Conditioners

RACK-MOUNT Air Conditioners

G /6000 BTU/Hr. 1172/1758 Watt. Specifications. Finish. Notes

SPECTRACOOL INDOOR/OUTDOOR

5736 N. Michigan Road Indianapolis, IN 46228

G /6000 BTU/Hr. 1172/1758 Watt

GENESIS Indoor Air Conditioners

G /6000 BTU/Hr. 1172/1758 Watt

5736 N. Michigan Road Indianapolis, IN 46228

Top-Mount Air Conditioners

T BTU/Hr. 234 Watts. T BTU/Hr. 586 Watts. Air Conditioners

PROAIR Harsh Environment/Wash Down Air Conditioners

ENCLOSURE AIR CONDITIONERS

N Volt 1800 BTU/Hr. 527 Watt. Specifications. Finish. Notes

Intelligent Electronic Enclosure Thermal Management Systems

VA G 052 S VA08 Indoor Model 1200, 1500 and 2000 Watts. Sealed Enclosure Cooling Air Conditioners

N Volt 1800 BTU/Hr. 527 Watt

N Volt 1800 BTU/Hr. 527 Watt

VA G 052 S VA08 Indoor Model 1200, 1500 and 2000 Watts. Sealed Enclosure Cooling Air Conditioners

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

Thermal Management INDEX. Management. Thermal TM-1

Series PIC. New Construction and Renovation; Replaces RetroAire VPAC and First Company DPU Application Flexible Quiet Comfort Damage Protection

Indoor and Outdoor Enclosures Outdoor Nema 3, 3R, 4, 4X Cabinet Enclosures LTE 4G Wimax Telecom Security Traffic

TECHNICAL SPECIFICATIONS

50TM TFF COMBINATION HEATING/COOLING UNITS

50TM COMBINATION HEATING/COOLING UNITS

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

AIR TO AIR HEAT EXCHANGERS

VA G 052 S

Series PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection

TECHNICAL SPECIFICATIONS

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

Signature Features. Stainless Steel Interior. Quiet Dishwasher. Delay Start. Multiple-Cycle Options. More Easy-To-Use Features. Product Dimensions

Quality Enclosures. Service Excellence.

MACH N-407 Heat Pump Air-Cooled Chiller

built-in comfort GE built-in air conditioners and heat pumps

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Heat Pumps COMFORT NEED IT. When You

CF1 ProVector Explosion-Proof Heaters

Horizon Elite Ice Machine Installation Instructions for Remote Condensing Unit

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

Coil-In-Tank Design: Refrigeration System: Cabinet Construction:

LANDE SmartQube 19 Air-Conditioned Cabinet

McQuay Suite Type N Top Mounted Hydronic Heat Incremental Packaged Terminal Air Conditioners C:

MOBILE COOLING BUYING GUIDE EVERYTHING YOU NEED TO KNOW

Tall-Tub Design. Our large capacity, tall-tub dishwasher fits up to 12 place settings so you can wash more at once. SpaceWise Silverware Basket

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

62DA,DB,DC,DD,DE,DF07-38

CX1 ProVector Explosion-Proof Heaters

Noncycling Refrigerated Air Dryers Range AD 10 to AD 4000

Cozy Hi Wall Inverter Air Conditioner

APC APPLICATION NOTE #109

AC, HP and Air Handler Units Up to 20 Tons. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

THRU-THE-WALL AIR CONDITIONERS

built-in comfort GE built-in air conditioners New product introductions January 2010

13 SEER CONDENSING UNITS

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

Packaged Terminal Air Conditioners

Service Parts for RMR Wall-Mount Enclosures

Unit Features & Benefits RQPM/RQRM Series

Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS. Technical Bulletin. Products that provide lasting solutions.

50Hz AC, HP and Air Handler Units Up to 70 kw. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

MODEL NUMBER: SRCOOL60KCW

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT

Outstanding Performance; Application Flexibility

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL

AHRI Certification Program Scopes - COOLING

Packaged Terminal Air Conditioner (PTAC)

Packaged Terminal Air Conditioner (PTAC)

Product Data. Fig. 1 - Unit 50VR -A

13 SEER HEAT PUMPS. Featuring Earth-Friendly R-410A Refrigerant 13PJL SERIES. Features Coils constructed with copper tubing and enhanced aluminum

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan

BLUEWAY DC INVERTER AIR TO WATER HEAT PUMP

48TM GAS HEATING/ELECTRIC COOLING UNITS

Capacity: 1.5 to 6.0 Ton

precision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs

FIGURE 1 Forced Convection Method. Filter & Grille Required. Ambient Air. Filter & Grille Required

E Z S E R I E S " W X 16" H

CHAPTER12. Thermal Management. Featured Products in this Chapter. Outdoor Air Conditioners T15, T20 and T29 Series 800-4,000 BTU/Hr. P.

ProAir CR43 INSTRUCTION MANUAL FOR: McLean Thermal Business Park Blvd. N Champlin, MN Tel: Fax:

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

WZT High Efficiency Air to Water Split System Heat Pumps With E.V.I. Compressors

Packaged Terminal Air Conditioner (PTAC)

GREEN REFRIGERANT R-410A

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

Liebert CRV Warranty Inspection Check Sheet

WLCG/WLHG. Specifications and Performance WLCG/WLHG. (with EMI AmericaSeries condensers)

Owner s Manual. Important Safety Information. Operating Instructions The Controls on Your Air Conditioner Care of Product

Self-Contained & Split System Reverse Cycle Air Conditioners SAB Self-Contained Units, CAB Condensers and DEAH Air Handlers

Air Conditioning THERMAL MANAGEMENT SOLUTIONS FOR ELECTRICAL ENCLOSURES

VACPB1 Series - 60 Hz Models

Transcription:

D E F E N D E R Datacom Cabinets 3,000 BTU DEFENDER server cabinets are an efficient, self-contained cooling system ideal for use in remote locations, wiring closets, and industrial environments that don t have cooling infrastructure already in place. Capable of providing up to 4 kw of cooling, these cabinets with NEM rated air conditioners protect the delicate electronics inside from heat, dirt, moisture, and tampering. Simply put, these cabinets are a cost-effective alternative to installing a data center with a climate-controlled cooling system. Part Number: DC-28U2436-C3000-D Cabinet 28U Rack Space 24 Wide 36 Deep + C Unit 3,000 BTU Please consider the following: what are the cooling needs of the equipment that will be housed in the cabinet, what is the height and width of the smallest door or elevator on the path to installation, what is the size of the room where the cabinet will reside, and is there a dedicated receptacle -in the room- capable of handling the power needs of an C unit. For retrofit jobs; the condition of the existing equipment, the type of rack it is currently housed in, and most importatnly the length of service loop, if any, of the existing cable. Cabinet Features Welded 12-gauge steel frame with 2000 static load capacity 28U rack space with square hole rails 36 depth standard 30 and 42 depths available Fully gasketed locking front and rear doors Gland plate in top for cable entry/exit Remote monitoring capability Compatible with 3,000 BTU C units Cooling capacity approximately 1.0 kw C Features Designed to mount on the side of the enclosure while maintaining NEM 12, 3R, 4, or 4X integrity. 120V / 3,000 BTU Digital temperature controller with alarm Built-in condensate evaporator Efficient, quiet, long lasting rotary compressor Environment friendly HFC refrigerant Easy pull-out filter UL Listed Complete Defender Line 3,000 BTU ~1.0 kw cooling 6,000 BTU ~2.0 kw cooling 12,000 BTU ~4.0 kw cooling 1

DEFENDER Datacom Cabinets C Unit lso vailable in 400V as non UL Conditioned Enclosure ir Flow mbient ir Flow Volts* BTU / Watts Max mps Max Temp Weight HxWxD mm [ ] 120 3,000 / 879 6.9 131 F / 55 C 55 lbs. / 25.0 kg, 764 x 312 x 161 [30.09 x 12.27 x 6.34] *C unit available in 230V if required. sk sales representative for details. Technical Specifications 28U 1422 [56.00] 764 [30.09] 76 [3.00] Front (w/o door) Front Right Side Back Left Side 600 [24.00] 770 [30.34] 988 [38.88] 312 [12.27] 95 x 95 [3.75 x 3.75] 450 [17.72] 390 x 495 max [15.25 x 19.50] 465 [18.30] Section - Top Mounting Dimension Bottom Top (w/ gland plate open) 2

D E F E N D E R Datacom Cabinets 6,000 BTU DEFENDER server cabinets are an efficient, self-contained cooling system ideal for use in remote locations, wiring closets, and industrial environments that don t have cooling infrastructure already in place. Capable of providing up to 4 kw of cooling, these cabinets with NEM rated air conditioners protect the delicate electronics inside from heat, dirt, moisture, and tampering. Simply put, these cabinets are a cost-effective alternative to installing a data center with a climate-controlled cooling system. Part Number: DC-28U2436-C6000-D Cabinet 28U Rack Space 24 Wide 36 Deep + C Unit 6,000 BTU Please consider the following: what are the cooling needs of the equipment that will be housed in the cabinet, what is the height and width of the smallest door or elevator on the path to installation, what is the size of the room where the cabinet will reside, and is there a dedicated receptacle -in the room- capable of handling the power needs of an C unit. For retrofit jobs; the condition of the existing equipment, the type of rack it is currently housed in, and most importatnly the length of service loop, if any, of the existing cable. Cabinet Features Welded 12-gauge steel frame with 2000 static load capacity 28U rack space with square hole rails 36 depth standard 30 and 42 depths available Fully gasketed locking front and rear doors Gland plate in top for cable entry/exit Remote monitoring capability Compatible with 6,000 BTU C units Cooling capacity approximately 2.0 kw C Features Designed to mount on the side of the enclosure while maintaining NEM 12, 3R, 4, or 4X integrity. 120V / 6,000 BTU Digital temperature controller with alarm Built-in condensate evaporator Efficient, quiet, long lasting rotary compressor Environment friendly HFC refrigerant Easy pull-out filter UL Listed Complete Defender Line 3,000 BTU ~1.0 kw cooling 6,000 BTU ~2.0 kw cooling 12,000 BTU ~4.0 kw cooling 3

DEFENDER Datacom Cabinets C Unit 5500 & 6000 BTU H Model BTU/Watts Volts Max mps Max Temp ºF/ºC Weight (lbs/kg) Dimensions (In/mm) IQ5500VS 5000/1465 120/60 10.4 131/55c 75 / 34.0 H 30.09 (764mm) x W 12.27 (312mm) x D 10.39 (264mm) IQ5500VS 5000/1465 230/60/50 5.2/5.7 140/60c 75 / 34.0 H 30.09 (764mm) x W 12.27 (312mm) x D 10.39 (264mm) IQ5500VS** 5000/1465 480/60/50 2.1/2.3 140/60c 92 / 41.7 H 34.12 (867mm)x W 12.27 (312mm) x D 10.39 (264mm) IQ6000VS 6000/1758 120/60 8.0 131/55c 77 / 35.0 H 30.09 (764mm) x W 12.27 (312mm) x D 10.39 (264mm) IQ6000VS 6000/1758 230/60/50 4.0/4.4 131/55c 80 / 36.3 H 30.09 (764mm) x W 12.27 (312mm) x D 10.39 (264mm) IQ6000VS** 6000/1758 480/60/50 1.9/2.1 n/a 92 / 41.7 H 34.12 (867mm)x W 12.27 (312mm) x D 10.39 (264mm) ** lso available in 400V as non UL lso vailable in 400V as non UL ir flow for IQ5500VS Conditioned Enclosure ir Flow mbient ir Flow Ice Qube, Inc., 141 Wilson ve., Greensburg, P 15601 Call: 724.837.7600 Fax: 724.837.3386 2-24-15 Rev 1 www.iceqube.com Email: sales@iceqube.com Volts* BTU / Watts Max mps Max Temp Weight HxWxD mm [ ] 120 6,000 / 1758 8.0 131 F / 55 C 77 lbs. / 35.0 kg, 764 x 312 x 263 [30.09 x 12.27 x 10.34] *C unit available in 230V if required. sk sales representative for details. Technical Specifications 28U 1422 [56.00] 764 [30.09] 76 [3.00] Front (w/o door) Front Right Side Back Left Side 600 [24.00] 872 [34.34] 988 [38.88] 312 [12.27] 95 x 95 [3.75 x 3.75] 450 [17.72] 390 x 495 max [15.25 x 19.50] 465 [18.30] Section - Top Mounting Dimension Bottom Top (w/ gland plate open) 4

D E F E N D E R Datacom Cabinets DEFENDER server cabinets are an efficient, self-contained cooling system ideal for use in remote locations, wiring closets, and industrial environments that don t have cooling infrastructure already in place. Capable of providing up to 4 kw of cooling, these cabinets with NEM rated air conditioners protect the delicate electronics inside from heat, dirt, moisture, and tampering. Simply put, these cabinets are a cost-effective alternative to installing a data center with a climate-controlled cooling system. Part Number: DC-28U2436-C8000-D Cabinet 28U Rack Space 24 Wide 36 Deep + C Unit Please consider the following: what are the cooling needs of the equipment that will be housed in the cabinet, what is the height and width of the smallest door or elevator on the path to installation, what is the size of the room where the cabinet will reside, and is there a dedicated receptacle -in the room- capable of handling the power needs of an C unit. For retrofit jobs; the condition of the existing equipment, the type of rack it is currently housed in, and most importatnly the length of service loop, if any, of the existing cable. Cabinet Features Welded 12-gauge steel frame with 2000 static load capacity 28U rack space with square hole rails 36 depth standard 30 and 42 depths available Fully gasketed locking front and rear doors Gland plate in top for cable entry/exit Remote monitoring capability Compatible with C units Cooling capacity approximately 2.6 kw C Features Designed to mount on the side of the enclosure while maintaining NEM 12, 3R, 4, or 4X integrity. 120V / Digital temperature controller with alarm Built-in condensate evaporator Efficient, quiet, long lasting rotary compressor Environment friendly HFC refrigerant Easy pull-out filter UL Listed Complete Defender Line 3,000 BTU ~1.0 kw cooling 6,000 BTU ~2.0 kw cooling 12,000 BTU ~4.0 kw cooling 5

Corrosive Packages Crankcase Heater DEFENDER Datacom Cabinets C Unit 8000 BTU H Technical Data Model BTU/Watts Volts Max mps Max Temp ºF/ºC Weight (lbs/kg) Dimensions (In/mm) IQ8000V16 8000/2345 120/60 13.7 131/55c 105 / 47.6 H 42.09 (1069mm) x W 15.93 (405mm) x D 10.34 (263mm) IQ8000V16 8000/2345 230/60/50 6.8/7.5 131/55c - (50Hz 140/60c) 105 / 47.6 H 42.09 (1069mm) x W 15.93 (405mm) x D 10.34 (263mm) IQ8000V16** 8000/2345 480/60/50 3.4/3.7 131/55c 130 / 59.0 H 46.15 (1172mm) x W 15.93 (405mm) x D 10.34 (263mm) * Designed for high ambient applications ** lso available in 400V as non UL Conditioned Enclosure ir Flow mbient ir Flow Volts* BTU / Watts Max mps Max Temp Weight HxWxD mm [ ] Ice Qube, Inc., 141 Wilson ve., Greensburg, P 15601 Call: 724.837.7600 Fax: 724.837.3386 120 8,000 2-24-15 Rev / 2345 1 13.7 www.iceqube.com 131 F / 55 CEmail: sales@iceqube.com 105 lbs. / 47.6 kg, 1069 x 404 x 263 [42.09 x 15.93 x 10.34] *C unit available in 230V if required. sk sales representative for details. Technical Specifications 28U 1422 [56.00] 1069 [42.09] Front (w/o door) Front 76 [3.00] Right Side Back Left Side 600 [24.00] 872 [34.34] 988 [38.88] 404 [15.93] 95 x 95 [3.75 x 3.75] 450 [17.72] 390 x 495 max [15.25 x 19.50] 465 [18.30] Section - Top Mounting Dimension Bottom Top (w/ gland plate open) 6

D E F E N D E R Datacom Cabinets DEFENDER server cabinets are an efficient, self-contained cooling system ideal for use in remote locations, wiring closets, and industrial environments that don t have cooling infrastructure already in place. Capable of providing up to 4 kw of cooling, these cabinets with NEM rated air conditioners protect the delicate electronics inside from heat, dirt, moisture, and tampering. Simply put, these cabinets are a cost-effective alternative to installing a data center with a climate-controlled cooling system. Part Number: DC-40U2442-C8000-D Cabinet 40U Rack Space 24 Wide 42 Deep + C Unit Please consider the following: what are the cooling needs of the equipment that will be housed in the cabinet, what is the height and width of the smallest door or elevator on the path to installation, what is the size of the room where the cabinet will reside, and is there a dedicated receptacle -in the room- capable of handling the power needs of an C unit. For retrofit jobs; the condition of the existing equipment, the type of rack it is currently housed in, and most importatnly the length of service loop, if any, of the existing cable. Cabinet Features Welded 12-gauge steel frame with 2000 static load capacity 28U rack space with square hole rails 42 depth standard 30 and 36 depths available Fully gasketed locking front and rear doors Gland plate in top for cable entry/exit Remote monitoring capability Compatible with C units Cooling capacity approximately 2.6 kw C Features Designed to mount on the side of the enclosure while maintaining NEM 12, 3R, 4, or 4X integrity. 120V / Digital temperature controller with alarm Built-in condensate evaporator Efficient, quiet, long lasting rotary compressor Environment friendly HFC refrigerant Easy pull-out filter UL Listed Complete Defender Line 3,000 BTU ~1.0 kw cooling 6,000 BTU ~2.0 kw cooling 12,000 BTU ~4.0 kw cooling 7

Corrosive Packages Crankcase Heater DEFENDER Datacom Cabinets C Unit 8000 BTU H Technical Data Model BTU/Watts Volts Max mps Max Temp ºF/ºC Weight (lbs/kg) Dimensions (In/mm) IQ8000V16 8000/2345 120/60 13.7 131/55c 105 / 47.6 H 42.09 (1069mm) x W 15.93 (405mm) x D 10.34 (263mm) IQ8000V16 8000/2345 230/60/50 6.8/7.5 131/55c - (50Hz 140/60c) 105 / 47.6 H 42.09 (1069mm) x W 15.93 (405mm) x D 10.34 (263mm) IQ8000V16** 8000/2345 480/60/50 3.4/3.7 131/55c 130 / 59.0 H 46.15 (1172mm) x W 15.93 (405mm) x D 10.34 (263mm) * Designed for high ambient applications ** lso available in 400V as non UL Conditioned Enclosure ir Flow mbient ir Flow Volts* BTU / Watts Max mps Max Temp Weight HxWxD mm [ ] Ice Qube, Inc., 141 Wilson ve., Greensburg, P 15601 Call: 724.837.7600 Fax: 724.837.3386 120 2-24-15 8,000 Rev / 12345 13.7 www.iceqube.com 131 F / 55 C Email: sales@iceqube.com 105 lbs. / 47.6 kg, 1069 x 404 x 263 [42.09 x 15.93 x 10.34] *C unit available in 230V if required. sk sales representative for details. Technical Specifications 40U 1955 [77.00] 1069 [42.09] 76 [3.00] Front (w/o door) Front Right Side Back Left Side 600 [24.00] 872 [34.34] 1120 [44.13] 404 [15.93] 95 x 95 [3.75 x 3.75] 450 [17.72] 390 x 495 max [15.25 x 19.50] 465 [18.30] Section - Top Mounting Dimension Bottom Top (w/ gland plate open) 8

D E F E N D E R Datacom Cabinets 12,000 BTU DEFENDER server cabinets are an efficient, self-contained cooling system ideal for use in remote locations, wiring closets, and industrial environments that don t have cooling infrastructure already in place. Capable of providing up to 4 kw of cooling, these cabinets with NEM rated air conditioners protect the delicate electronics inside from heat, dirt, moisture, and tampering. Simply put, these cabinets are a cost-effective alternative to installing a data center with a climate-controlled cooling system. Part Number: DC-40U2442-C12000-D Cabinet 40U Rack Space 24 Wide 42 Deep + C Unit 12,000 BTU Please consider the following: what are the cooling needs of the equipment that will be housed in the cabinet, what is the height and width of the smallest door or elevator on the path to installation, what is the size of the room where the cabinet will reside, and is there a dedicated receptacle -in the room- capable of handling the power needs of an C unit. For retrofit jobs; the condition of the existing equipment, the type of rack it is currently housed in, and most importatnly the length of service loop, if any, of the existing cable. Cabinet Features Welded 12-gauge steel frame with 2000 static load capacity 28U rack space with square hole rails 42 depth standard 30 and 36 depths available Fully gasketed locking front and rear doors Gland plate in top for cable entry/exit Remote monitoring capability Compatible with 12,000 BTU C units Cooling capacity approximately 4.0 kw C Features Designed to mount on the side of the enclosure while maintaining NEM 12, 3R, 4, or 4X integrity. 120V / 12,000 BTU Digital temperature controller with alarm Built-in condensate evaporator Efficient, quiet, long lasting rotary compressor Environment friendly HFC refrigerant Easy pull-out filter UL Listed Complete Defender Line 3,000 BTU ~1.0 kw cooling 6,000 BTU ~2.0 kw cooling 12,000 BTU ~4.0 kw cooling 9

DEFENDER Datacom Cabinets C Unit 10,000, & 12,000 BTU H Model BTU/Watts Volts Max mps Max Temp ºF/ºC Weight (lbs/kg) Dimensions (In/mm) IQ10000V 10000/2931 120/60 15.1 131/55c 135 / 61.2 H 52.09 (1323mm) x W 17.65 (448mm) x D 10.34 (263mm) IQ10000V 10000/2931 230/60/50 7.9/8.7 140/60c 135 / 61.2 H 52.09 (1323mm) x W 17.65 (448mm) x D 10.34 (263mm) IQ10000V** 10000/2931 480/60/50 4.0/4.4 140/60c 173 / 78.5 H 57.65 (1464mm) x W 17.65 (448mm) x D 10.34 (263mm) IQ12000V 12000/3517 120/60 19.6 131/55c 135 / 61.2 H 52.09 (1323mm) x W 17.65 (448mm) x D 10.34 (263mm) IQ12000V 12000/3517 230/60/50 9.8/10.8 135/57c - (50Hz 140/60c) 135 / 61.2 H 52.09 (1323mm) x W 17.65 (448mm) x D 10.34 (263mm) IQ12000V** 12000/3517 480/60/50 4.9/5.4 131/55c 173 / 78.5 H 57.65 (1464mm) x W 17.65 (448mm) x D 10.34 (263mm) ** lso available in 400V as non UL g g pp Conditioned Enclosure ir Flow mbient ir Flow Ice Qube, Inc., 141 Wilson ve., Greensburg, P 15601 Call: 724.837.7600 Fax: 724.837.3386 2-24-15 Rev 1 www.iceqube.com Email: sales@iceqube.com Volts* BTU / Watts Max mps Max Temp Weight HxWxD mm [ ] 120 12,000 / 3517 19.6 131 F / 55 C 135 lbs. / 61.2 kg, 1323 x 448 x 263 [52.09 x 17.65 x 10.34] *C unit available in 230V if required. sk sales representative for details. Technical Specifications 40U 1955 [77.00] 1323 [52.09] 76 [3.00] Front (w/o door) Front Right Side Back Left Side 600 [24.00] 872 [34.34] 1120 [44.13] 448 [17.65] 95 x 95 [3.75 x 3.75] 450 [17.72] 390 x 495 max [15.25 x 19.50] 465 [18.30] Section - Top Mounting Dimension Bottom Top (w/ gland plate open) 10