Fan Heaters Type VLEx

Similar documents
Fan Heaters Type TXI, WBK, WBG, Delta & VLE

Explosion-proof Immersion Heater Type D-8660

Finned Tube Air Heaters Type WD/GG (RVS)

Sinus Jevi (Explosion-Proof) Condens Heaters

Temperature Measurement Transmitters for field mounting

CCAC. Ex d. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66. Stainless steel bolts.

ExPolar Heating System

Dräger Polytron 5700 IR Detection of flammable gases and vapours

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

Hazardous Area Portable Fan Heater The Bulldog

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

Integrated Solutions Low Voltage Systems

Enclosure Heaters. Zone 1, Zone 2 & Safe Area

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Indoor/outdoor resistance thermometer Model TR60

Dräger Polytron 8310 IR Detection of flammable gases and vapour

EN54-5, ATEX and IECEx approved Highly durable Automatic reset after cooling Range of alarm temperatures

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

Hazardous Area Portable Fan Heater The Bulldog

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Flameproof Manual Call Points Series MCP

Hazardous Area Portable Fan Heater The Bulldog

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

ATEX. Tough controls for tough environments. ia.danfoss.com. Brochure Controls. Danfoss controls - designed and approved for hazardous areas

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

Illumination unit For sight glass level indicator Model LGI

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

IMMERSION HEATERS IMMERSION HEATERS FOR WATER 1½ BRASS NIPPLE, 3X400V: 2 BRASS NIPPLE, 3X400V:

Product manual reducers, adapters, plugs etc. INDEX ELEKTRO BV Harregatplein VP Zuidland Netherlands

Flameproof Manual Call Points Series MCP

Manual Power relay SR853

Trusted worldwide since 1989 INTRINSICALLY SAFE RANGE

Multiple Status Indicators Series MEXE, MS25, MS35, MS45, MS55

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Dräger Polytron 5100 EC Detection of toxic gases and vapors

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

OPTIBAR DP 7060 Supplementary Instructions

Dräger Polytron 8720 IR Detection of carbon dioxide

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

INTRINSICALLY SAFE LIGHTING RANGE

Technical Data. General specifications. Rated operating distance s n 5 mm

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S

AEU1. Explosion-Proof Electric Air Heater For Hazardous Locations

manual addendum DELPHI Ex

PRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

stego_katalog_2008_en.qxp:englisch :09 Uhr Seite 1 Product Catalogue

Fixed Gas Detection System/Meridian CERTIFICATION

Industrial Cast-in Circulation Heaters for ATEX/IECEx hazardous areas or in non-atex version

products 22 º C Ventilation Air Conditioning Refrigeration Unit heaters Inside PROVIDED BY HEINEN & HOPMAN

INSTRUCTION MANUAL (ATEX / IECEx)

Flange immersion heaters

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

your dust explosion protection experts

Inductive slot sensor

INSTRUCTION MANUAL (ATEX / IECEx)

Performance Data. Accessories Enclosure Heaters. curus Component Recognized; File No. E IP 20 CE

Performance Data. curus Component Recognized; File No. E IP 20

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

TBSF/CBSF Stainless Steel Flat Roof Screwed Terminal Box Zones 1&2, 21&22

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

FOR PERFECT THERMAL MANAGEMENT WORLDWIDE

Main switch current K: with main switch (optional)

Danfoss gas detection unit Type GD Heavy Duty

Dräger Flame 2700 (Multi-IR) Flame Detection

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Gas cylinder scale Model GCS-1

Electrical Heat Tracing in Hazardous Areas. innovations in heat tracing

DOO IK ENG PRODUCT CATALOG DOO IK ENG TEMPERATURE SENSOR PRESSURE SWITCH NON FLOW SWITCH THERMOMETER

Technology. Drum H eaters ZIEGLER ENGINEERING. Metal drum heater design

GENERAL OVERVIEW ELECTRIC HEATERS - EXCHANGERS - PACKAGES ELECTRIC HEATING SOLUTIONS ELECTRIC HEATERS EXCHANGERS PACKAGES

GUB. Ex d. Screw-on lid. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 8 sizes - IP66. Polyester coating. Cast mounting feet

Dräger Polytron 5720 IR Toxic Gas Detection

Element: Stainless steel (encapsulated) resistance wire. Fresh-Air-Fan 2 capacities. Standing model IP24

Integrated industrial sensor solutions for real world conditions

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

Dräger Flame 2500 (IR3) Flame Detection

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Hazardous Area Signalling

Temperature measurement with SITRANS T siemens.com/processinstrumentation

Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE

Dräger Flame 2350 (UV&IR) Flame Detection

SOLUZIONI PER ATMOSFERA ESPLOSIVA

Dräger Flame 2100 (UV) Flame Detection

ILED Aquarius CIRCLE-H Mk 2 Helideck Lighting System

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

ATEX catalogue book SOLUTIONS FOR EXPLOSIVE ATMOSPHERES

Operating Manual Distribution box

XB Convection Heater. Convection Heaters. Applications. Special Wattage and Lengths. Selection of Temperature Code. Construction and Installation

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors

Ex LED light fittings

Ex Mark:Ex d eb ⅡB T6 Gb

Dräger Flame 2370 (UV&IR) Flame Detection

FINAL ATEX REPORT ON EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES FOR GOLDEN PROMISE EQUIPMENT INC. FLOW MONITOR, GPE3000 SERIES,

ATEX DELVALLE GENERAL CATALOGUE FLEXIBLE SOLUTIONS FOR HAZARDOUS AREAS UNDER ATEX & IECEX DIRECTIVES.

ATEX JEVI A/S ISO 9001 A12295 EXPLOSION PROOF ELECTRICAL HEATERS FOR INDUSTRIAL AND OFFSHORE APPLICATIONS

SPECIFICATION SHEET. Installation, Operation, Maintenance Instructions for safety use Series EX SOCKET SWITCH

Transcription:

Fan Heaters Type VLEx Fan Heater type VLEx has been designed for Explosion Proof industrial applications. Our Fan Heaters are characterized mainly by their quality, both in used materials and design. Liquids Gasses Solids Spaces Resistors Sinus-Jevi Electric Heating B.V. Aambeeld 19 1671 NT Medemblik +31 (0) 227 549 100 www.sinusjevi.com

VLEx Fan Heaters VLEx fan heaters are for fix mounting (non-portable) and are ideal for use in classified zone 1 & 2, where high performance of heating is required. It has a very robust construction. The fan heater is made of materials able to withstand aggressive effects at sea, on offshore installations, in warehouses and for large manufacturing facilities. The fan provides an airflow/circulation and air heating for outdoor or indoor installation. MATERIALS Cabinet and heater junction box: stainless steel AISI 316L d-enclosure: casted aluminium Heating elements: stainless steel AISI 316L, bright annealed STANDARDS AND APPROVALS CE IEC/EN 61000-6-2:2006 EN 60335-1:2012 IEC/EN 61000-6-4:2007 EN 60335-2-30:2009 IEC/EN 60079-1 EN 60204-1:2006 IEC/EN 60079-7 EN 62233:2008 IEC/EN 60079-11 EN 50581:2012 IEC/EN 60079-14 VLEx fan heaters approved by DNV and/or ABS on request. MARKING ATEX & IEC Ex db eb IIC T3 Gb or Ex db eb [ia] IIC T3 Gb TECHNICAL DATA Voltage range: 3x400V, 3x440V, 3x480V and 3x690V Degree of protection for fan motor: IP55 Degree of protection for heater junction box (e-enclosure) and d-enclosure: IP66 Integrated safety components TSHH, with manual outside reset to prevent overheating Overcurrent protection to prevent the motor to overheat Cable glands Supplied with M32 cable glands for Ø17 - Ø26,3 cable Type: CMP Material: nickle plated brass Lifting lugs Supplied with lifting lugs to ensure safe working conditions during installation and maintenance. Control: On/Off control with cirquit breaker Ambient temperature: -25 C to +50 C Storage temperature: -25 C to +50 C ACCESSORIES FOR VLE Ex FAN HEATERS In addition to our standard range shown on next page, optional extras are available: Integrated room thermostat: 0-40 C thermostat, ensuring optimum operation and minimising energy consumption. Choose between location inside: - the Ex e control panel or - the Ex d control panel Room thermostat for wall mounting 0-40 C TSH, temperature range 0-200 C Flow switch Main switch RTD (PT100 sensor and 4-20mA transmitter instead of integrated room thermostat, for external control Cable gland reducer nickle plated brass to M25 for Ø11,1 - Ø20 cable Cable gland reducer nickle plated brass to M20 for Ø6,5 - Ø14 cable Gland nickle plated brass M32 Gland nickle plated brass M32 + M25 + M20 See our standard range on the following pages. Back view VLEx 2

STANDARD PROGRAMME Type: VLEx - S (small) Power: 3.5-7 - 10.6 kw Material: - Cabinet and heater junction box: Stainless steel AISI 316L - d-enclosure: casted aluminium - Heating elements: stainless steel AISI 316L, bright annealed Size: W776 x H500 x D755 mm Frequency: 50/60 Hz Maximum volume of air at nominal fan speed for: 3.5kW: 1550/1890 m³/h 7 and 10.6 kw: 2500/3500 m³/h - 50/60Hz Degree of protection for control panels: IP66 Degree of protection for fan motor: IP55 Ambient temperature: -25 C to +50 C Storage temperature: -25 C to +50 C Type Power VLEx - S 3.5 kw VLEx - S 7 kw VLEx - S 10.6 kw Frequency 50Hz Frequency 60Hz Voltage Current (min. supply) 21960201 21960202 3x400V 6 A 21960203 21960204 3x440V 6 A 21960205 21960206 3x480V 5 A 21960207 21960208 3x690V 4 A 21960209 21960210 3x400V 11 A 21960211 21960212 3x440V 10 A 21960213 21960214 3x480V 9 A 21960215 21960216 3x690V 7 A 21960217 21960218 3x400V 16 A 21960219 21960220 3x440V 15 A 21960221 21960222 3x480V 14 A 21960223 21960224 3x690V 10 A db (A) (50/60Hz) 51/55 56/61 3

STANDARD PROGRAMME Type: VLEx - M (medium) Power: 11.7-15.6-19.5 kw Material: - Cabinet and heater junction box: Stainless steel AISI 316L - d-enclosure: casted aluminium - Heating elements: stainless steel AISI 316L, bright annealed Size: W936 x H665 x D755 mm Frequency: 50/60 Hz Maximum volume of air at nominal fan speed for: 3800/4600 m³/h Degree of protection for control panels: IP66 Degree of protection for fan motor: IP55 Ambient temperature: -25 C to +50 C Storage temperature: -25 C to +50 C Type Power VLEx - M 11.7 kw VLEx - M 15.6 kw VLEx - M 19.5 kw Frequency 50Hz Frequency 60Hz Voltage Current (min. supply) 21960225 21960226 3x400V 18 A 21960227 21960228 3x440V 16 A 21960229 21960230 3x480V 15 A 21960231 21960232 3x690V 11 A 21960233 21960234 3x400V 24 A 21960235 21960236 3x440V 21 A 21960237 21960238 3x480V 20 A 21960239 21960240 3x690V 14 A 21960241 21960242 3x400V 29 A 21960243 21960244 3x440V 27 A 21960245 21960246 3x480V 24 A 21960247 21960248 3x690V 17 A db (A) (50/60Hz) 60/64 4

STANDARD PROGRAMME Type: (large) Power: 23.4-27.3-31.2-35.1 kw Material: - Cabinet and heater junction box: Stainless steel AISI 316L - d-enclosure: casted aluminium - Heating elements: stainless steel AISI 316L, bright annealed Size: W936 x H665 x D950 mm Frequency: 50/60 Hz Maximum volume of air at nominal fan speed for: 4800/6800 m³/h Degree of protection for control panels: IP66 Degree of protection for fan motor: IP55 Ambient temperature: -25 C to +50 C Storage temperature: -25 C to +50 C Type Power 23.4 kw 27.3 kw 31.2 kw 35.1 kw Frequency 50Hz Frequency 60Hz Voltage Current (min. supply) 21960249 21960250 3x400V 35 A 21960251 21960252 3x440V 32 A 21960253 21960254 3x480V 30 A 21960255 21960256 3x690V 21 A 21960257 21960258 3x400V 41 A 21960259 21960260 3x440V 37 A 21960261 21960262 3x480V 34 A 21960263 21960264 3x690V 24 A 21960265 21960266 3x400V 47 A 21960267 21960268 3x440V 42 A 21960269 21960270 3x480V 39 A 21960271 21960272 3x690V 27 A 21960273 21960274 3x400V 52 A 21960275 21960276 3x440V 48 A 21960277 21960278 3x480V 44 A 21960279 21960280 3x690V 30 A db (A) (50/60Hz) 65/68 5

Sinus was one of the pioneers in the field of explosion proof heating equipment, today we are still operating at the forefront. We design and manufacture according to ATEX as well as IECEx and EAC directives. Our company is certified to design and produce Ex-equipment. and we also in the possession of ISO 9001 and ISO 14001 certificates. VLEx.1102E 07-17 Sinus-Jevi Electric Heating B.V. Aambeeld 19 1671 NT Medemblik +31 (0) 227 549 100 www.sinusjevi.com