48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

Similar documents
50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

48TM GAS HEATING/ELECTRIC COOLING UNITS

48TF GAS HEATING/ ELECTRIC COOLING UNITS

50TM TFF COMBINATION HEATING/COOLING UNITS

50TM COMBINATION HEATING/COOLING UNITS

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

48PGD/E/F/L/M/N PG20-28

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT

Model 655A Sizes

HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, , 18, 20, and 25 NOMINAL TONS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Product Data. Features/Benefits. 50ZP Single-Package Electric Cooling Units. 2 to 5 Nominal Tons

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

RGE 13 A T - 1 A

Product Data. 50JZ Single-Package Heat Pump Units with Puron (R-410A) Refrigerant. 2 to 5 Nominal Tons

62DA,DB,DC,DD,DE,DF07-38

Product Data. Features/Benefits. 50GX 3-PHASE SINGLE-PACKAGED ELECTRIC COOLING UNITS 2-1/2 to 5 Nominal Tons

Model 702A SINGLE-PACKAGED ELECTRIC HEATING COOLING UNITS. 2 to 5 Nominal Tons UNIT 702A. Form No. PDS 702A.24.3

13 GEP A L P - 1 A

Product Data. Fig. 1 - Unit 50VR -A

30GT FLOTRONIC AIR-COOLED CHILLERS

Product Data. Features/Benefits. 50LJQ Single-Package Rooftop Heat Pump Units. Nominal 3 to 10 Tons

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat

PAR5. Product Specifications

Product Data. Features/Benefits

Product Data. 50GS Single-Packaged Electric Cooling Units. 1-1/2 to 5 Nominal Tons

Product Data. 50ZP Single-Package Air Conditioners. 2 to 5 Tons

30GN FLOTRONIC II AIR-COOLED CHILLERS

Product Data. 50JS Single-Packaged Heat Pump Units. 1 1/2 to 5 Nominal Tons

Product Data FEATURES/BENEFITS. 574A ---Low NOx Models Available SINGLE---PACKAGED GAS HEATING/ELECTRIC COOLING UNITS 2To5NominalTons

Model PA1Z SINGLE PACKAGED AIR CONDITIONERS. Size SS-PA1Z-01 DESCRIPTION FEATURES

Product Data. 50ZH Single-Packaged Heat Pumps. 2 to 5 Tons. Features/Benefits

EER PACKAGE AIR CONDITIONER, 6.9 to 14.4 kw, 2 4 TONS 3 Phase, Standard CFM / Ls EER

Product Data. Fig. 1 - Unit 50VG -A

High Heat COP. High/Low Stage

Product Data. Features/Benefits. Infinity 13 48XZ Single-Packaged Dual-Fuel Gas Heating/Electric Heat Pump Units with Puron (R-410A) Refrigerant

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

Product Data. Features/Benefits. 50HX High Efficiency Single-Packaged Heat Pumps. 2 to 5 Nominal Tons

Product Data. Features/Benefits. 50JS 3-PHASE SINGLE-PACKAGED HEAT PUMP UNITS 2-1/2 to 5 Nominal Tons

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

Product Data. Features/Benefits. PERFORMANCE 13 50XP SINGLE-PACKAGED ELECTRIC COOLING UNITS WITH PURON (R-410A) REFRIGERANT 2 to 5 Nominal Tons

HEAT EXCHANGER Aluminized serpentine clamshell heat exchanger provides corrosion resistance for longer life and efficient heat transfer.

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER

DCG Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

Submittal Data 558F SINGLE-PACKAGE ELECTRIC HEATING/ ELECTRIC COOLING UNITS NOMINAL TONS DESCRIPTION FEATURES

Model 574B Sizes

50VT--C Comfort 14 SEER Single--Packaged Heat Pump System with Puron

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h

Model 704B Sizes

Product Data. Features/Benefits

Product Data. Fig. 1 - Unit 50EZ -A

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING

Product Data. Features/Benefits. 50JZ 3-PHASE SINGLE-PACKAGED HEAT PUMP UNITS with Puron (R-410A) Refrigerant 2-1/2 to 5 Nominal Tons

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Product Data. Features/Benefits. PERFORMANCE 13 50XZ SINGLE-PACKAGED HEAT PUMP UNITS WITH PURON (R-410A) REFRIGERANT 2 to 5 Nominal Tons

PAJ3. Product Specifications

30GXN,R AIR-COOLED LIQUID CHILLERS WITH COMFORTLINK CONTROLS 50/60 Hz

DCG Commercial. Submittal Data Form

WPH4 Product Specifications

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

607C- -A PREFERREDt SINGLE-PACKAGED HEAT PUMP SYSTEM WITH PURONR (R-410A) REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS (SIZES 24-60)

48XZ Performance 13 SEER Single--Packaged HYBRID HEAT Dual Fuel System with Puron

Product Data. 50GL Single-Package Electric Cooling Units with Puron (R-410A) Refrigerant. 2 to 5 Nominal Tons

50GL Single-Packaged Electric Cooling 50Hz, CE Units with Puron (R-410A) Refrigerant Features/Benefits

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

Product Data PY3G SINGLE -PACKAGED AIR CONDITIONER AND GAS FURNACE SYSTEM WITH R -410A REFRIGERANT SINGLE AND 3 PHASE 2-5 NOMINAL TONS (SIZES )

PRODUCT SPECIFICATIONS 2YCC3048A1120A /1/ /

SKYPAK II, 3 Ton Series, gives you a

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

Model 583A Sizes

4YCC3048A3096A /3/ /

Product Data. Fig. 1 - Unit 50ES -A

2YCC3060A1120A /1/ / YCC3060A1096A /1/ /

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

Model 581A COMMERCIAL GAS HEATING/ELECTRIC COOLING UNITS. Bryant Air Conditioning. Form No. PDS 581A.155.3B. 13 to 20 Tons DESCRIPTION

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Product Data. Features/Benefits. 48TJ Single-Package Rooftop Units Electric Cooling/Gas Heating. 3 to 25 Nominal Tons

SPECIFICATIONS 4YCC3060A-SPEC-1A SINGLE PACKAGED GAS HEATING ELECTRIC COOLING 4YCC3060A1096/120B TAG:

Model 579F/580D. Sizes COMMERCIAL SINGLE PACKAGE ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS. 3to25Tons. Form No. PDS 580D.36.

SKYPAK II, 3 Ton Series, gives you a

Product Data. Fig. 1 - Unit 50XL -A

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

Product Catalog. Packaged Rooftop Air Conditioners Foundation Electric/Electric Tons, 50 Hz RT-PRC073B-EN. May 2018

Product Data. 48GX/48GXN Single-Package Gas Heating/Electric Cooling Units. 2 to 5 Nominal Tons

Product Data. Fig. 1 - Unit 48XL -A

Transcription:

-3SB 018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING S PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1997 Carrier Corporation Syracuse, New York 13221 Form -3SB Supersedes -2SB Printed in U.S.A. 5-97 Catalog No. 514-847

Date: Supersedes: 018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING S Rev.: -3SB JOB DATA: LOCATION: BUYER: BUYER P.O. # CARRIER # NUMBER: MODEL NUMBER: PERFORMANCE DATA CERTIFIED BY: DATE: ARI 210 ARI 270 Standard one-year warranty. Five-year Extended Protection Plan for the compressor. Ten-year non-prorated warranty on heat exchanger. Units are Rated in accordance with ARI Standard No. 270 and 210/240. Standard unit as factory assembled is design certified and listed by UL and CSA. Low temperature cooling operation standard to 40 F (4 C). Hermetic compressor with internal linebreak and overload protection, self lubricating. Scroll compressors on 4 and 5 ton sizes. Crankcase heater is standard on 024-042 3-phase units. (Not required on 018, 048 and 060 units.) Indoor and outdoor coils constructed of aluminum fins mechanically bonded to seamless copper tubes. units have single-stage cooling and heating. Foil-faced cleanable insulation. Sloped non-corrosive condensate drain pan. DESCRIPTION units are standard-efficiency, one-piece gas heating electric cooling units, pre-wired and pre-charged at the factory. units are convertible discharge units that can be used for either horizontal or down discharge installations. FEATURES Single-point gas connection. Alternate electrical connections on opposite sides of unit. Disconnect in accordance with NEC, must be field-supplied and installed. Multi-speed, direct drive indoor fan motor. Weatherized cabinets. Heavy duty phosphated zinc-coated prepainted steel. Capable of withstanding 500-hour salt spray. 24-volt control circuit. Heating controls include a direct spark ignition with flame rectification. Fan switch, overtemperature switch, and flame rollout switch also included. Induced-draft with hall effect sensor (to prove proper inducer draft motor operation). Alumaguard coated Super-S four-pass heat exchanger. Integrated gas control board provides anti-cycle protection for gas heat operation. Base rail standard on all 3-phase units. PERFORMANCE DATA Operating Weight lb (unit); lb (curb) CFM Ext. Static Pressure in. wg COOLING Indoor Fan Motor Hp Rpm Bhp Net Total Capacity Btuh Net Sensible Capacity Btuh HEATING Compressor Power Input kw @ F Input Btuh Outdoor-Air Temperature Output Btuh Indoor Entering Air db F wb F SEER/EER AFUE % ELECTRICAL DATA Power Supply to Unit Volts Phase Hz. Minimum Circuit Amps Maximum Overcurrent Protection ACCESSORIES AND OPTIONS FACTORY-INSTALLED OPTIONS Commercial Grade Base Rail Dedicated Downshot/Base Rail FIELD-INSTALLED ACCESSORIES 30% Open Manual Fresh Air Damper Roof Curb: 8 Height 11 Height 14 Height One-in. Filter Rack Crankcase Heater Single Phase Only (Required with 0 Low Ambient) FIELD-INSTALLED ACCESSORIES (cont) Programmable Electronic Thermostat Thermostat and Subbase 0 Low Ambient Time Guard II L.P. Conversion Kit Controls Upgrade Kit (High and Low-Pressure Switch) External Condensate Trap Natural Gas High-Altitude Kit (2000-5000 ft Above Sea Level) 2

CERTIFIED DIMENSION PRINT REQ D CLEARANCES FOR SERVICING Duct Panel........................ 0 Unit Top..................... 36 (914.4) Side Opposite Ducts.............. 36 (914.4) Compressor Access.............. 36 (914.4) (Except for NEC requirements) REQ D CLEARANCES TO COMBUSTIBLE MAT L Maximum Extension of Overhangs...... 48 (1219.2) Unit Top..................... 14 (355.6) Duct Side of Unit................. 2 (50.8) Side Opposite Ducts.............. 14 (355.6) Bottom of Unit...................... 0 Flue Panel................... 36 (914.4) NEC (National Electrical Code) REQ D CLEARANCES Between Units, Control Box Side....... 42 (1066.8) Unit and Ungrounded Surfaces, Control Box Side............... 36 (914.4) Unit and Block or Concrete Walls and Other Grounded Surfaces, Control Box Side... 42 (1066.8) OUTDOOR COIL INDOOR COIL ELECTRICAL CHARACTERISTICS WEIGHT CORNER WEIGHT (lb/kg) lb kg A B C D 018040 208/230-1-60 272 123 81/37 62/28 76/35 53/24 024040 208/230-1-60 303 138 97/44 43/20 123/56 40/18 024060 208/230-1-60 315 143 100/45 46/21 126/57 43/20 030040 208/230-1-60 320 145 100/45 47/21 126/57 47/21 030060/080 208/230-1-60 324 147 94/43 63/29 115/52 52/24 036060/080 208/230-1-60 336 153 86/39 76/35 111/50 63/29 036100/120 208/230-1-60 348 158 89/40 79/36 114/52 66/30 042060/080 208/230-1-60 375 170 95/43 86/39 119/54 75/34 042100/120 208/230-1-60 387 176 98/45 89/40 122/55 78/35 HEIGHT DIMENSION CENTER OF GRAVITY E F G X Y Z 018040 24.12/612.8 16 9 16/420.7 18 15 16/481.0 25.07/637 20.59/523 10.85/276 024040 24.12/612.8 16 9 16/420.7 18 15 16/481.0 27.07/688 23.35/693 10.85/276 024060 24.12/612.8 16 9 16/420.7 18 15 16/481.0 26.98/685 23.27/591 10.85/276 030040 24.12/612.8 16 9 16/420.7 18 15 16/481.0 26.71/678 23.46/596 10.85/276 030060/080 24.12/612.8 16 9 16/420.7 18 15 16/481.0 27.15/689 22.36/568 10.85/276 036060/080 24.12/612.8 16 9 16/420.7 18 15 16/481.0 27.50/698 22.48/571 10.85/276 036100/120 24.12/612.8 16 9 16/420.7 18 15 16/481.0 27.40/696 22.44/570 10.85/276 042060/080 28.12/714.2 20 9 16/522.3 22 15 16/582.6 27.01/686 22.44/570 12.65/321 042100/120 28.12/714.2 20 9 16/522.3 22 15 16/582.6 26.94/684 22.44/570 12.65/321 NOTE: Clearances must be maintained to prevent recirculation of air from outdoor fan discharge. INDOOR COIL ACCESS 3

4 CERTIFIED DIMENSION PRINT REQ D CLEARANCES FOR SERVICING Duct Panel................... 0 Unit Top................ 36 (914.4) Side Opposite Ducts......... 36 (914.4) Compressor Access.......... 36 (914.4) (Except for NEC requirements) REQ D CLEARANCES TO COMBUSTIBLE MAT L Maximum Extension of Overhangs............. 48 (1219.2) Unit Top................ 14 (355.6) Duct Side of Unit............. 2 (50.8) Side Opposite Ducts......... 14 (355.6) Bottom of Unit.................. 0 Flue Panel............... 36 (914.4) NEC (National Electrical Code) REQ D CLEARANCES Between Units, Control Box Side................. 42 (1066.8) Unit and Ungrounded Surfaces, Control Box Side........... 36 (914.4) Unit and Block or Concrete Walls and Other Grounded Surfaces, Control Box Side.......... 42 (1066.8) OUTDOOR COIL INDOOR COIL ELECTRICAL WEIGHT CORNER WEIGHT (lb/kg) CHARACTERISTICS lb kg A B C D 018040 208/230-1-60 296 135 87/40 68/31 82/37 59/27 024040 208/230-1-60 327 149 103/47 49/22 129/59 46/21 024060 208/230-1-60 339 155 106/48 52/24 132/60 49/22 030040 208/230-1-60, 208/230-3-60 344 157 106/48 53/24 132/60 53/24 030060/080 208/230-1-60, 208/230-3-60 356 162 102/46 71/32 123/56 60/27 036060/080 360 164 92/42 82/37 117/53 69/31 036100/120 372 169 95/43 85/39 120/55 72/33 042060/080 460-3-60 399 181 101/46 92/42 125/57 81/37 042100/120 208/230-1-60, 208/230-3-60 460-3-60 411 187 104/47 95/43 128/58 84/38 HEIGHT DIMENSION CENTER OF GRAVITY E F G X Y Z 018040 27.43/696.7 19 7 8/504.8 22 1 4/565.4 25.04/636.0 22.72/577.0 13.16/334.3 024040 27.43/696.7 19 7 8/504.8 22 1 4/565.4 26.90/683.3 20.17/512.3 13.16/334.3 024060 27.43/696.7 19 7 8/504.8 22 1 4/565.4 26.82/681.2 20.22/513.6 13.16/334.3 030040 27.43/696.7 19 7 8/504.8 22 1 4/565.4 26.57/674.9 20.05/509.3 13.16/334.3 030060/080 27.43/696.7 19 7 8/504.8 22 1 4/565.4 26.93/684.0 21.08/535.4 13.16/334.3 036060/080 27.43/696.7 19 7 8/504.8 22 1 4/565.4 27.31/693.7 20.97/532.6 13.16/334.3 036100/120 27.43/696.7 19 7 8/504.8 22 1 4/565.4 27.23/691.6 20.99/533.1 13.16/334.3 042060/080 31.43/798.3 23 7 8/606.4 26 1 4/666.8 26.87/682.5 20.99/533.1 14.96/380.0 042100/120 31.43/798.3 23 7 8/606.4 26 1 4/666.8 26.81/681.0 21.01/533.7 14.96/380.0 NOTE: Clearances must be maintained to prevent recirculation of air from outdoor fan discharge, with the exception of the outdoor coil as stated. A removable fence or barricade requires no clearance. INDOOR COIL ACCESS

CERTIFIED DIMENSION PRINT REQ D CLEARANCES FOR SERVICING Duct Panel........................ 0 Unit Top..................... 36 (914.4) Side Opposite Ducts.............. 36 (914.4) Compressor Access.............. 36 (914.4) (Except for NEC requirements) REQ D CLEARANCES TO COMBUSTIBLE MAT L Maximum Extension of Overhangs...... 48 (1219.2) Unit Top..................... 14 (355.6) Duct Side of Unit................. 2 (50.8) Side Opposite Ducts.............. 14 (355.6) Bottom of Unit...................... 0 Flue Panel................... 36 (914.4) NEC (National Electrical Code) REQ D CLEARANCES Between Units, Control Box Side....... 42 (1066.8) Unit and Ungrounded Surfaces, Control Box Side............... 36 (914.4) Unit and Block or Concrete Walls and Other Grounded Surfaces, Control Box Side... 42 (1066.8) OUTDOOR COIL INDOOR COIL ELECTRICAL CHARACTERISTICS WEIGHT CORNER WEIGHT (lb/kg) lb kg A B C D 048080 208/230-1-60 414 188 107/49 83/38 158/72 66/30 048100/120/140 208/230-1-60 426 193 110/50 86/39 159/72 71/32 060080 208/230-1-60 453 206 117/53 93/42 167/76 76/35 060100/120/140 208/230-1-60 465 211 120/55 96/44 167/76 82/37 CENTER OF GRAVITY X Y Z 048080 28.76/731 23.46/596 15.35/390 048100/120/140 28.42/722 23.42/595 15.35/390 060080 28.36/720 23.27/591 15.35/390 060100/120/140 27.95/710 23.23/590 15.35/390 NOTE: Clearances must be maintained to prevent recirculation of air from outdoor fan discharge. INDOOR COIL ACCESS 5

6 CERTIFIED DIMENSION PRINT REQ D CLEARANCES FOR SERVICING Duct Panel................. 0 Unit Top.............. 36 (914.4) Side Opposite Ducts....... 36 (914.4) Compressor Access....... 36 (914.4) (Except for NEC requirements) REQ D CLEARANCES TO COMBUSTIBLE MAT L Maximum Extension of Overhangs........... 48 (1219.2) Unit Top.............. 14 (355.6) Duct Side of Unit.......... 2 (50.8) Side Opposite Ducts....... 14 (355.6) Bottom of Unit............... 0 Flue Panel............ 36 (914.4) OUTDOOR COIL INDOOR COIL 048080 048100/120/140 060080 060100/120/140 ELECTRICAL CHARACTERISTICS WEIGHT CORNER WEIGHT (lb/kg) lb kg A B C D 438 199 113/51 89/40 164/75 72/33 450 205 116/53 92/42 165/75 77/35 477 217 123/56 99/45 173/79 82/37 489 222 126/57 102/46 173/79 88/40 CENTER OF GRAVITY X Y Z 048080 28.54/724.9 20.00/508.0 17.66/448 048100/120/140 28.22/716.8 20.05/509.3 17.66/448 060080 28.18/715.8 20.19/512.8 17.66/448 060100/120/140 27.79/705.9 20.23/513.8 17.66/448 NEC (National Electrical Code) REQ D CLEARANCES Between Units, Control Box Side............................ 42 (1066.8) Unit and Ungrounded Surfaces, Control Box Side.................... 36 (914.4) Unit and Block or Concrete Walls and Other Grounded Surfaces, Control Box Side......................... 42 (1066.8) NOTE: Clearances must be maintained to prevent recirculation of air from outdoor fan discharge. INDOOR COIL ACCESS

CERTIFIED ROOF CURB DIMENSION PRINT NOTES: 1. Roof curb must be set up for unit being installed. 2. Seal strip must be applied as required for unit being installed. 3. Dimensions in [ ] are in millimeters. 4. Roof curb is made of 16 gage steel. 5. Attach ductwork to curb (flanges of duct rest on curb). 6. Service clearance 4 ft on each side. 7. Direction of airflow. PART NUMBER CURB A CPRFCURB001A00 8 [203] CPRFCURB002A00 FLAT 11 [279] CPRFCURB003A00 14 [356] 8. Insulated Panels: 1-in. thick fiberglass 1 lb density. 7