Instruction Sheet AquaMotionHot One AMH1K-1 Point of Use Hot Water Recirculation System

Similar documents
SINGLE SPEED CIRCULATORS

Chilipepper CP9000. Installation Instructions READ BEFORE INSTALLING:

Comfort Series Instant Hot Water System

Pre-Fab Easy Installation For Model 0011-CF-USK Installation and Operating Instructions for Existing Homes Or Buildings with Standard Piping

INSTANT HOT WATER RECIRCULATING SYSTEM

Installation and Operating Instructions

SAVE THESE INSTRUCTIONS

Installation Instructions

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Chilipepper CP8000. Installation Instructions READ BEFORE INSTALLING:

HELIATOS Bottom Feed Connector Installation Instructions Introduction. Step 1

Installation Instructions

Built-In Dishwasher. Installation Instructions. BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT The dishwasher MUST be

Top Control Dishwasher

Mini Tank water heater Electric undersink Water heaters GL GL 4 - GL 6+

Dishwasher Installation Instructions DW 24XT/DW 24XV

Installation Instructions Built-In Dishwasher

Installation Instructions

Installation Instructions Built-In Dishwasher

Laing Thermotech. Autocirc The Instant Hot Water Pump Models E1-BCANCT1W-06 and E1-BCANRT1W. Installation & Operating Manual

E. F. G. H. I. J. K. L. M. Alternate Energy Technologies, LLC. P F


HOMEADVANTAGE II IMPORTANT SAFETY INFORMATION

Installation and Operating Instructions

A PROUD HERITAGE OF EXPERIENCE & QUALITY DISHWASHER BR- DWSH01- S

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

SPEAKMAN SAFETY PRODUCTS Installation Instructions SEF-TW

TABLE 1. Specifications: Dimensions: 6¼ x 9 5/8 x 2 ¾

EEMAX SERIES-TWO WATER HEATERS

INSTALLATION & OPERATING INSTRUCTIONS

General System Layout Sketch

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Installation Instructions

Remote Water Quality System Standard Equipment (supplied by EPI) Remote Water Quality System Optional Equipment (supplied by EPI)

OUTDOOR DISHWASHER INSTALLATION INSTRUCTIONS

WAIWELA SERIES-TWO WATER HEATERS

Clean Water Made Easy. CWS Time Clock Softener Installation & Start Up Guide. Questions?

Installation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324

Installation Instructions

Installation instructions Built-in. Dishwasher READCAREFUL KEEPTHESE INSTRUCTIONS. Model(s): DDW2405BL. IMPORTANT: The dishwasher MUST be installed to

Installation Instructions Built-In Dishwasher

Dishwasher Installation Manual

PRO SERIES IMPORTANT SAFETY INFORMATION

OWNER S MANUAL AND INSTALLATION GUIDE PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING INSTALLATION

DISHWASHER INSTALLATION INSTRUCTIONS

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

Instant Hot Water Dispenser Owner s Manual

Instantaneous Oil-Fired Water Heater. Installation Manual OM-148. (Type B)

Installation Instructions Air Pump

KD-27A SERIES DISHWASHERS

Installation Instructions

Instantaneous Oil-Fired Water Heater. Installation Manual OM-148. (Type D)

kk21 installation Kk21-WF21 Things you might need for the installation: vessel sink,

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS

Installation Instructions

SMARTBOOST IMPORTANT SAFETY INFORMATION

IB 835. Installation Manual. Integrated Bidet Toilet TABLE OF CONTENTS

J-PRO-24 Soda Ash Injection Installation & Start-Up Guide

WM-450-PT WM-900-PT Commercial Wall Mounted Reverse Osmosis

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL TANKBUDDY IMPORTANT SAFETY INFORMATION

Electric Mini Tank Water Heaters ME10 ME25 ME40 ME60

CHUGGER PUMP Chugger Max Models

TABLE 1 Electrical Specifications

ELECTRIC INSTANTANEOUS WATER HEATER INSTALLATION GUIDE AND OWNERS MANUAL THERMOSTATIC

Installation Instructions

Installation Instructions Built-In Dishwasher

Dimensions: 39 1/2" w x 22" D x 35.5 H. kk25 installation. Things you might need for the installation: vessel sink,

Acrylic Claw Foot Tub

INSTANT-FLOW C-MICRO WATER HEATER

Astro Express 2 - Hot Water Delivery System

EEMAX THREE MODULE, SINGLE PHASE WATER HEATERS

TABLE 1 Electrical Specifications. Phase

One Less Thing to Forget...

215 Gallon Waste Oil Tank With Bypass Regulator Installation Instructions

Installing the Turbo Floor Model System

Model EPWHP. How to install, operate and maintain your Water Heater Protector. Do not return unit to store

IMPORTANT INFORMATION. Revised Dishwasher Installation Instructions

THE INNOVATION LEADER IN HOT WATER RECIRCULATION

Acrylic Claw Foot Tub

HotLine Internal Sewer Pipe Heater Installation Manual

EEMAX ProAdvantage Series 1

Two Tier Illumifalls Patio Pond

POWERSTAR PS19T / PS28T, SINGLE PHASE WATER HEATERS

COMPASS HIGH-EFFICIENCY WET-ROTOR CIRCULATORS

Water Boilers ME10EN, ME15EN. Table of Contents

INSTALLATION, OPERATION AND SERVICE MANUAL AERATION SYSTEMS FEATURING AIR COMPRESSOR AND AIR ELIMINATOR TANK

en-us Use and Care Manual, Installation Instructions Washer WAT28400UC

Installation Instructions

J-PRO-24 Pump Chlorinator. Installation & Start-Up Guide

Kallista Bath Flip Drain

Installation Instructions

Drinking Water Purification Systems

Installation Manual PS-225 & PS-275

Cascade Premier and Elite Premier Bathing Systems with Aqua-Aire Installation / Assembly Instructions

Installation Instructions

I<enmore Elite. instructions d'lnstallation. Installation Guide Instrucciones de Instalaci6n. English / EspaioJ / Frangais

Clean & Clear. Cartridge Filter System Owner s Manual IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

General System Layout Sketch

SS1095 Ice Maker.

GL2.5 Ti GL4Ti GL8Ti

Transcription:

Effective: 5/13/15 Supersedes: New IS-AM09-601 Instruction Sheet Point of Use Hot Water Recirculation System THANK YOU for purchasing a new Aquamotion Hot System! For optimum reliability and performance please follow the installation instructions outlined below. NOTE: Please note that this is not an anti-scald unit. There may be some warm water in the cold water line under the sink where the circulator is installed. Once the cold water line is opened, the warm water will disappear in a short time. (Longer hot water lines may result in longer time for hot water to reach the sink.) APPLICATION The AquaMotionHot One circulators are designed to deliver hot water instantly at the point of use (under sink). Water savings can be as great as 12,000 15,000 gallons per year for a family of four. The AMH1K-1 circulator together with the Aquamotion Hook up and Go accessories are designed to be user friendly, reliable and to produce a professional installation. WARNING: Risk of electric shock. The AMH1K-1 kits are supplied with a grounding conductor and grounding type attachment plug. To reduce the risk of electric shock, be certain that it is connected only to a properly grounding type receptacle. WARNING: When installing The AMH1K-1 observe all applicable electrical and plumbing codes. WARNING: To avoid electrical shock, disconnect power prior to connecting or disconnecting The AMH1K-1. WARNING: Risk of electric shock. The AMH1K-1 has not been investigated for use in swimming pool or marine areas. WARNING: The AMH1K-1 is acceptable for indoor use only. Employer uniquement a l interieur. CAUTION: The AMH1K-1 has been evaluated for use with water only. The suitability of The AMH1K-1 for use with liquids other than water is the responsibility of the end user. CAUTION: When making electric connections, do not apply excessive external loads to the junction box. SYSTEM REQUIREMENTS Minimum water pressure 20 psi Maximum water pressure 125 psi Maximum water temperature 176F (80 C) SHIPMENT INSPECTION Examine all components carefully to ensure they are all present and they have not been damaged in transit to you. Care should be taken to avoid dropping or mishandling the AMH1K-1. Damage to the AMH1K-1 may occur if it is dropped. KIT CONTENTS The AMH1K-1 Hot One package includes: (1) Pump, model AM1-SU1LAM complete with mounting bracket and pre-wired 10 foot flexible cord. (1) Union tail piece without red marking. (1) Union tail piece with red marking. (2) Union nuts. (2) Union gaskets. (2) Flex hoses 3/8 compression x 1/2 NPS, 22 inches long. (2) Tee, 3/8 x 3/8 x 3/8 compression. REQUIRED TOOLS 2 - Pipe wrenches which open to at least 1 1/2 1 - Adjustable wrench which opens to at least 1 INSTRUCTIONS for AMH1K-1 (see Fig. 1) 1. Locate the hot and cold shut off valves (angle stops) typically located near the faucet(s) under the counter. 2. Close both shut off valves and disconnect the flexible hoses attached to each valve by turning the nut at the end of the hoses counter-clockwise. 3. Install one Tee at each valve. Connect the female port of the Tee to the port on the valves from which you have just disconnected the hoses. 4. Connect the hoses which you had disconnected from the valves to the top port of the Tee. MAKE SURE YOU CONNECT THE HOSES TO THE SAME VALVE TO WHICH THEY HAD ORIGINALLY BEEN CONNECTED. 5. Attach the unions (gaskets, nuts and tail pieces) to the pump casing. The gaskets must be located between pump casing and tail piece. MAKE SURE THE TAIL PIECE MARKED RED IS MATCHED UP WITH THE RED MARKING ON THE INLET SIDE (THAT IS OPPOSITE DIRECTION OF ARROW) OF THE PUMP. You will need two pipe wrenches which open to at least 1 1/2 inches. Firmly tighten the two union nuts to avoid leaks. Do not install the pump upside down. 6. Place the pump into its intended location with the bracket on the floor and fasten with screws if necessary. It is also possible to install the pump horizontally but make sure that the wall to which it is fastened is sturdy enough to support the pump NOTE: Be sure the arrows on the pump point to the cold water side. 7. Install the flex hoses by attaching one end to the remaining port of the Tee and the other end to the pump. MAKE SURE THE HOSE ATTACHED TO THE HOT VALVE IS CONNECTED TO THE INLET SIDE (THAT IS THE OPPOSITE DIRECTION OF THE ARROW) OF THE PUMP. MAKE SURE THE HOSE ATTACHED TO THE COLD VALVE IS CONNECTED TO THE DISCHARGE SIDE (THAT IS THE SIDE THE ARROW IS POINTING TO) OF THE PUMP. 8. Open the valves. Check for leaks. 9. Plug in the cord to any convenient grounded, 115 volt outlet. 10. The system will settle in 2 to 3 hours. Opening faucets will help release the air

Effective: 5/13/15 Supersedes: New IS-AM09-601 (Figure 1) (Under Sink Installation Instructions) Kit Contents Installation Picture

Effective: 9/1/15 IS-AM09-611 Instruction Sheet Point of Use Hot Water Recirculation System THANK YOU for purchasing a new Aquamotion Hot System! For optimum reliability and performance please follow the installation instructions outlined below. NOTE: Please note that this is not an anti-scald unit. There may be some warm water in the cold water line under the sink where the circulator is installed. Once the cold water line is opened, the warm water will disappear in a short time. (Longer hot water lines may result in longer time for hot water to reach the sink.) APPLICATION The AquaMotionHot One circulators are designed to deliver hot water instantly at the point of use (under sink). Water savings can be as great as 12,000 15,000 gallons per year for a family of four. The AMH3K-7 circulator together with the Aquamotion Hook up and Go accessories are designed to be user friendly, reliable and to produce a professional installation. WARNING: Risk of electric shock. The AMH3K-7 kits are supplied with a grounding conductor and grounding type attachment plug. To reduce the risk of electric shock, be certain that it is connected only to a properly grounding type receptacle. WARNING: When installing The AMH3K-7 observe all applicable electrical and plumbing codes. WARNING: To avoid electrical shock, disconnect power prior to connecting or disconnecting The AMH3K-7. WARNING: Risk of electric shock. The AMH3K-7 has not been investigated for use in swimming pool or marine areas. WARNING: The AMH3K-7 is acceptable for indoor use only. Employer uniquement a l interieur. CAUTION: The AMH3K-7 has been evaluated for use with water only. The suitability of The AMH3K-7 for use with liquids other than water is the responsibility of the end user. CAUTION: When making electric connections, do not apply excessive external loads to the junction box. SYSTEM REQUIREMENTS Minimum water pressure 20 psi Maximum water pressure 125 psi Maximum water temperature 176F (80 C) SHIPMENT INSPECTION Examine all components carefully to ensure they are all present and they have not been damaged in transit to you. Care should be taken to avoid dropping or mishandling the AMH3K-7. Damage to the AMH3K-7 may occur if it is dropped. KIT CONTENTS The AMH3K-7 Hot One package includes: (1) Pump, model AM7-SU1LAM complete with mounting bracket, pre-wired 10 foot flexible cord, and built-in Aquastat (1) Union tail piece without red marking. (1) Union tail piece with red marking. (2) Union nuts. (2) Union gaskets. (2) Flex hoses 1/2 NPS x 1/2 NPS, 24 inches long. (2) Tee, 3/8 compression x 1/2 NPS x 3/8 compression. REQUIRED TOOLS (2) - Pipe wrenches which open to at least 1 1/2 (1) - Adjustable wrench which opens to at least 1 INSTRUCTIONS for AMH3K-7 (see Fig. 1) 1. Locate the hot and cold shut off valves (angle stops) typically located near the faucet(s) under the counter. 2. Close both shut off valves and disconnect the flexible hoses attached to each valve by turning the nut at the end of the hoses counter-clockwise. 3. Install one Tee at each valve. Connect the female port of the Tee to the port on the valves from which you have just disconnected the hoses. 4. Connect the hoses which you had disconnected from the valves to the top port of the Tee. MAKE SURE YOU CONNECT THE HOSES TO THE SAME VALVE TO WHICH THEY HAD ORIGINALLY BEEN CONNECTED. 5. Attach the unions (gaskets, nuts and tail pieces) to the pump casing. The gaskets must be located between pump casing and tail piece. MAKE SURE THE TAIL PIECE MARKED RED IS MATCHED UP WITH THE RED MARKING ON THE INLET SIDE (THAT IS OPPOSITE DIRECTION OF ARROW) OF THE PUMP. You will need two pipe wrenches which open to at least 1 1/2 inches. Firmly tighten the two union nuts to avoid leaks. Do not install the pump upside down. 6. Place the pump into its intended location with the bracket on the floor and fasten with screws if necessary. It is also possible to install the pump horizontally but make sure that the wall to which it is fastened is sturdy enough to support the pump NOTE: Be sure the arrows on the pump point to the cold water side. 7. Install the flex hoses by attaching one end to the remaining port of the Tee and the other end to the pump. MAKE SURE THE HOSE ATTACHED TO THE HOT VALVE IS CONNECTED TO THE INLET SIDE (THAT IS THE OPPOSITE DIRECTION OF THE ARROW) OF THE PUMP. MAKE SURE THE HOSE ATTACHED TO THE COLD VALVE IS CONNECTED TO THE DISCHARGE SIDE (THAT IS THE SIDE THE ARROW IS POINTING TO) OF THE PUMP. 8. Open the valves. Check for leaks. 9. Plug in the cord to any convenient grounded, 115 volt outlet. 10. The system will settle in 2 to 3 hours. Opening faucets will help release the air 88C Jefferson Blvd, Warwick, RI 02888 401-785-3000 www.aquamotionhvac.com info@aquamotionhvac.com

Effective: 9/1/15 IS-AM09-611 (Figure 1) (Under Sink Installation Instructions) Kit Contents Installation Picture 88C Jefferson Blvd, Warwick, RI 02888 401-785-3000 www.aquamotionhvac.com info@aquamotionhvac.com

Effective: 10/08/15 IS-AM09-612 Instruction Sheet AquaMotionHot One AMH3K-R Point of Use Hot Water Recirculation System THANK YOU for purchasing a new Aquamotion Hot System! For optimum reliability and performance please follow the installation instructions outlined below. NOTE: Please note that this is not an anti-scald unit. There may be some warm water in the cold water line under the sink where the circulator is installed. Once the cold water line is opened, the warm water will disappear in a short time. (Longer hot water lines may result in longer time for hot water to reach the sink.) (2) Tee, 1/2 compression x 3/4 NPT x 1/2 compression REQUIRED TOOLS 2 - Open-end wrenches 5/8 and 11/16 1 - Adjustable wrench which opens to at least 1 1/4 INSTRUCTIONS for AMH3K-R 1. Turn off the house water supply 2. Open both the hot and cold faucets. This will relieve any remaining water pressure in water pipes APPLICATION The AquaMotionHot One circulators are designed to deliver hot water instantly at the point of use (under sink). Water savings can be as great as 12,000 15,000 gallons per year for a family of four. The AMH3K-R circulator together with the Aquamotion Hook up and Go accessories are designed to be user friendly, reliable and to produce a professional installation. WARNING: Risk of electric shock. The AMH3K-R kits are supplied with a grounding conductor and grounding type attachment plug. To reduce the risk of electric shock, be certain that it is connected only to a properly grounding type receptacle. WARNING: When installing The AMH3K-R observe all applicable electrical and plumbing codes. WARNING: To avoid electrical shock, disconnect power prior to connecting or disconnecting The AMH3K-R. WARNING: Risk of electric shock. The AMH3K-R has not been investigated for use in swimming pool or marine areas. WARNING: The AMH3K-R is acceptable for indoor use only. Employer uniquement a l interieur. CAUTION: The AMH3K-R has been evaluated for use with water only. The suitability of The AMH3K-R for use with liquids other than water is the responsibility of the end user. CAUTION: When making electric connections, do not apply excessive external loads to the junction box. SYSTEM REQUIREMENTS Minimum water pressure 20 psi Maximum water pressure 125 psi Maximum water temperature 176F (80 C) SHIPMENT INSPECTION Examine all components carefully to ensure they are all present and they have not been damaged in transit to you. Care should be taken to avoid dropping or mishandling the AMH3K-R. Damage to the AMH3K-R may occur if it is dropped. KIT CONTENTS The AMH3K-R Hot One package includes: (1) Pump, model AMR-S3FVAL with pre-wired 10 foot flexible cord. (2) 3/4 NPT male threaded stainless steel flanges. (2) Flange gaskets (2) Flex hoses 3/4 NPT x 3/4 NPT, 24 inches long. Aquamotion Tee Installation (see Fig. 1) 3. Locate the hot and cold shut off valves (angle stops) typically located near the faucet(s) under the counter. 4. Remove the shut off valves that supply hot and cold water lines to the sink from the copper pipe. For ease of installation you may leave the compression ring and nut from the angle stop on the hot and cold water supply lines*. 5. Remove the ferrule ring and nut from the compression fitting on the supplied Tee s and install them onto the copper supply pipes 6. Insert the ½ Copper tubing into the tee on the hot and cold water supply pipes. Tighten nuts securely 7. Thread the angle stops (valves) to the new Tee s. Both of these connections are compression fine threads. Never apply either Teflon tape or pipe dope on compression threads or fittings/ This will void the warranty of AquaMotion Tee s. 8. Install the flex hoses by attaching one end to the remaining port of the Tee and the other end to the pump. MAKE SURE THE HOSE ATTACHED TO THE HOT VALVE IS CONNECTED TO THE INLET SIDE (THAT IS THE OPPOSITE DIRECTION OF THE ARROW) OF THE PUMP. MAKE SURE THE HOSE ATTACHED TO THE COLD VALVE IS CONNECTED TO THE DISCHARGE SIDE (THAT IS THE SIDE THE ARROW IS POINTING TO) OF THE PUMP. Circulator Installation (see Fig. 2) 9. Attach the flanges and gaskets to the pump casing. The gaskets must be located between pump casing and flange. You will need two open-end wrenches 5/8 and 11/16 inches. Firmly tighten the nuts and bolts to avoid leaks. Do not install the pump upside down 10. Place the pump into its intended location supported by the flanges and pump support. NOTE: Be sure the arrows on the pump point to the cold water side. 88C Jefferson Blvd, Warwick, RI 02888 401-785-3000 www.aquamotionhvac.com info@aquamotionhvac.com

Effective: 10/08/15 IS-AM09-612 11. Open the valves. Check for leaks. 12. In case of air lock, turn the slotted screw on the relief valve counter clockwise 1 turn. DO NOT UNSCREW COMPLETELY. When water appears, close the valve by turning it clockwise 1 turn. (See Fig. 3) 13. Plug in the cord to any convenient grounded, 115 volt outlet. 14. Give the system 2 to 3 hours to settle. Opening faucets will help release the air. *If shut off valves (angle stops) do not have threaded connection, new shut off valves will be required Stainless hoses are NSF 61-9 listed Circulators are of stainless construction All Fittings are lead free (Figure 3) Air Lock Relief Valve (Figure 1) Shut Off Valve Installation AquaMotionHot One AMH3K-R Kit Contents (Figure 2) AquaMotionHot One AMH3K-R (Under Sink Installation) 88C Jefferson Blvd, Warwick, RI 02888 401-785-3000 www.aquamotionhvac.com info@aquamotionhvac.com