UNIVERSITI TEKNIKAL MALAYSIA MELAKA

Similar documents
IMPROVEMENT OF BUS ROOF SECTION

AIR CONDITIONING STUDY FOR AUTOMOTIVE APPLICATION ALAUDDIN HAFIZ BIN YUSOF UNIVERSITI MALAYSIA PAHANG

SMART GARDEN SYSTEM NURSHAHNEEM BINTI MOHD SAID

A SIMPLE ID DETECTION USING INFRARED SENSORS NOOR FARHANA HALIL BT ABDUL RAZAK

UNIVERSITI TEKNIKAL MALAYSIA MELAKA

Development of Anti-Theft Door System for Lecturer s Room

WIRELESS SECURITY SYSTEM UKASYAH BIN MAHAMOD

Samsiah binti Mohamad

GAS LEAKAGE MONITORING OVER THE NET WITH RASPBERRY PI MOHD FAEZ BIN AHMAD RAZLI

ANALYSIS AND MEASUREMENT FIBER OPTIC FAULT BY USING OPTICAL TIME DOMAIN REFLECTROMETER (OTDR) AKWANIZAM BIN AZMI

FENCE INTRUDER DETECTION SYSTEM (FIDS) CHUINK BENG CHEONG

UNIVERSITI TEKNIKAL MALAYSIA MELAKA

UNIVERSITI TEKNIKAL MALAYSIA MELAKA. Improving of Cool Air Evacuation Process for Home Application

MOTORCYCLE ANTI-THEFT SYSTEM (MATS) MUHAMAD ALIF BIN ABU

STORAGE WATER TANKS CLEANING ROBOT AFIZRUL IMAN BIN MOHAMED

UNIVERSITI TEKNIKAL MALAYSIA MELAKA

ANALYSIS OF HEAT GAIN AGAINST COOLING CAPACITY AT OCCUPIED BUILDING KOH KELVIN

UNIVERSITI TEKNIKAL MALAYSIA MELAKA

GSM MOBILE CAR ALARM SYSTEM NURHAZWANI BT SALEH

Design and Fabrication of Solar Assisted Drying Machine

POROSITY ARCHITECTURE IN ECOLOGICAL DESIGN TAN KWON CHONG

UNIVERSITI TEKNIKAL MALAYSIA MELAKA

IDENTIFICATION OF AUDIO AND ROOM PARAMETERS FOR OPTIMUM SPEECH INTELLIGIBILITY IN ROOM NG TSING CHUN UNIVERSITI TEKNOLOGI MALAYSIA

HUMIDITY CONTROL SYSTEM FOR ROLLING AND FERMENTING ROOM OF A TEA FACTORY

A COMPARISON BETWEEN TRADITIONAL PAVEMENT REHABILITATION METHOD AS COMPARED TO RECYCLING METHOD SITI MAZZUANA BINTI SHAMSUDDIN

APPLICATION OF BIM IN EARLY STAGE DESIGN COST ESTIMATION

UNIVERSITI TEKNOLOGI MARA

CENTRE OF STUDIES FOR BUILDING SURVEYING FACULTY OF ARCHITECTURE, PLANNING AND SURVEYING UNIVERSITI TEKNOLOGI MARA

UNIVERSITI TEKNIKAL MALAYSIA MELAKA

Design and Development of Prototyping High Pressure and High Temperature Steam Cleaning Jet

STUDY OF INTERNAL HEAT EXCHANGER EFFECTS ON CAR AIR CONDITIONING SYSTEM CHAN HONG KET

GEOGRAPHICAL ANALYSIS OF LIBYAN AIRPORTS AND THEIR POTENTIAL AS A HUB OF AIR TRANSPORTATION FOUAD D S ABDULWAFI UNIVERSITI TEKNOLOGI MALAYSIA

EFFECT OF FINE AGGREGATE ANGULARITY ON RUTTING RESISTANCE OF ASPHALT CONCRETE AC10

TABLE OF CONTENTS. iii iv vi. vii. xii xiii xvii xix

A Suitable Development Trend in Linear City Based On Smart Growth A Case Study in Lanzhou Urban Area ZHOU WEI

GREEN HIGHWAY ECOLOGY AND ECOSYSTEM PRESERVATION AND RESTORATION MUDATHIR OMER ADAM ARBAB

UNIVERSITI TEKNOLOGI MARA

DESIGN AND CONSTRUCTION OF A MICROCONTROLLER BASED UNDER AND OVER VOLTAGE PROTECTION DEVICE WITH ALARM NAT BEREGHA EREMIEMI (2006/24462EE)

NAZANEEN AHMED NASROULLA

ASSESSMENT OF PARKING DEMAND IMPACT ON ADJOINING ROADWAY NETWORK WAN NUR ALIFFA WAN RAMLI

PENGARUH KEDUDUKAN DAN KEADAAN TAPAK KE ATAS KOS PEMBINAAN TAPAK TELEKOMUNIKASI SURYYANY BT ABD RANI UNIVERSITI TEKNOLOGI MALAYSIA

ANALYZE ThJ SPRINKLER SYSTEM IN tjw LECTURE ROOM USINO CID (COMPUTATIONAL FLUID DYNAMICS) ANALYSIS. WJHAMAD KHUMAJM fin r,jzaiman

CENTRE OF STUDIES FOR BUILDING SURVEYING FACULTY OF ARCHITECTURE, PLANNING AND SURVEYING UNIVERSITI TEKNOLOGI MARA

DYNAMIC ANALYSES OF COMPOSITE FOOTBRIDGES EXCITED BY PEDESTRIAN INDUCED LOADS FARAZ SADEGHI UNIVERSITI TEKNOLOGI MALAYSIA

VISUAL REPRESENTATION OF NATURE IN THE LIBRARY SOMAYEH ROUSTAEI SADRY UNIVERSITI TEKNOLOGI MALAYSIA

FIRE ALARM WITH SECURITY SYSTEM MOHAMED FAIZ BIN MOHAMED MUSA

HEAT TRANSFER CHARACTERISTICS OF A HEAT EXCHANGER JAMIATUL ADAWIAH BT AB. SIDEK UNIVERSITI TEKNIKAL MALAYSIA MELAKA

ANALYSIS PERFORMANCE OF WAJA CAR AIR-CONDITIONING SYSTEM MUHAMAD AMIRUDIN BIN KAMALRUL BADRI

DESIGN OF A RECYCLE BIN TIN CAN CRUSHER MUHAMMAD HANIS BIN MUHAMMAD ZULKIFLI

EVALUATION OF CRACK RELIEF LAYER FOR ROADS AND HIGHWAYS KHAIRUL HAFIZ BIN MUSTAFA

TABLE OF CONTENTS CHAPTER TITLE PAGE DECLARATION DEDICATION ACKNOWLEDGEMENTS ABSTRACT ABSTRAK

UNIVERSITI TEKNOLOGI MARA IMPLICATION OF NIGHT-TIME LEISURE ACTIVITIES TOWARDS PLACE IDENTITY OF URBAN PUBLIC PARK IN SHAH ALAM AND PUTRAJAYA

PRELIMINARY STUDY ON BRICKS DRYING PROCESS USING MICROWAVE TECHNOLOGY SALEM SALAH ABDULLAH BAGABER UNIVERSITI TEKNOLOGI MALAYSIA

Final Year Project Report

FLOOD MAPPING FOR SUNGAI BUNUS MOHD IRSYAM NOORFAWANA BIN MASRI

HEDGES USED IN BACKGROUND OF THE STUDY SECTIONS OF ENGLISH DEPARTMENT THESES: A CASE STUDY AT DIAN NUSWANTORO UNIVERSITY THESIS

UNIVERSITI TEKNOLOGI MARA EFFECTIVENESS OF VESICULAR ARBUSCULAR MYCORRHIZA ON ROOT DEVELOPMENT OF SAGO PALM PLANTLETS

BOILED WATER TEMPERATURE MEASUREMENT SYSTEM USING PIC MICROCONTROLLER

ASSESSMENT OF URBAN GREEN SPACE BASED ON LANDSCAPE ECOLOGICAL PRINCIPLES SITI SYAMIMI BINTI OMAR

CONTENTS. Abstract. Abstrak. Acknowledgement. List of Figures. List of Tables. List of Symbols and Abbreviations CHAPTER 1.

FMNA SYSTEM (FORGET ME NOT ALERT SYSTEM) SHARON BOON KHAI YEN

THERMAL PERFORMANCE OF POTTED PLANTS IN MITIGATING INDOOR TEMPERATURE IN TROPICAL CLIMATE SHAHRUL BIN CHE ON UNIVERSITI TEKNOLOGI MALAYSIA

UNIVERSITI TEKNOLOGI MARA THE CONDITION OF OUTDOOR SCULPTURES IN ASEAN SCULPTURE GARDEN KUALA LUMPUR: A CONSERVATION STUDY NORA SOFIA MOHAMED YURAN

Solution: Problem: How can the air, and surfaces, be cleaned to lower the risk from the usual suspects? OR PACKAGE

DESIGN AND ANALYSIS OF ELECTRICAL IRON USING BOOTHROYD DEWHURST DFMA METHODOLOGY MOHD HAZUAN BIN MOHD ZAWAWI

NUTRIENT LEACHING IN PEAT AND LATERITIC SOIL TREATED WITH INORGANIC AND ORGANIC FERTILISER

A STRUCTURED CRITICAL SUCCESS FACTORS MODEL FOR THE IMPLEMENTATION OF GREEN RETROFIT PROJECTS REHMAASHINI JAGARAJAN UNIVERSITI TEKNOLOGI MALAYSIA

DESIGN FACTORS THAT INFLUENCE THE EFFECTIVE USE OF MEYDAN IN IRAN REIHANEH SADAT HAJMIRSADEGHI UNIVERSITI TEKNOLOGI MALAYSIA

NAZANEEN AHMED NASROULLA

WIRELESS Temperature Monitoring System for Blood Bank using Zigbee. Keywords: Temperature monitoring system; ZigBee; LabVIEW; internet; alarm

WIRELESS BASED HOME SECURITY WITH AUTOMATION SYSTEM WAN NORZIELA BINTI WAN ROSLI

THE DESIGN AND FABRICATION OF AN OIL VACUUM CLEANER FOR INDUSTRIAL USE

IN VITRO REGENERATION OF PINEAPPLE (Ananas comosus) L. MERR 'MD2' USING DIFFERENT CONCENTRATION OF INDOLE ACETIC ACID (IAA) AND KINETIN (KN) HORMONE

UNIVERSITI TEKNIKAL MALAYSIA MELAKA

Mediclean Complanate Ultra Clean Ventilation

SUSTAINABILITY ASSESSMENT OF COMPACT-CITY DEVELOPMENT USING GEODESIGN APPROACH AHMED ABDULHAFEDH OWAID UNIVERSITI TEKNOLOGI MALAYSIA

AQUAPONIC SYSTEM FOR SELF-SUSTAIN LIVING YAN YEN QUN

CLEAN AIR SYSTEM.

FLOW AND PERFORMANCE INVESTIGATIONS OF CENTRIFUGAL BLOWERS WITH AEROFOIL BLADED IMPELLERS

VIGOUR OF FUNGICIDE-TREATED AND UNTREATED MAIZE SEED FOLLOWING STORAGE VELOSHINIE GOVENDER

Table of Contents for the REGULATION (EU) 2017/745 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 5 April 2017

UVC in the Operating Room.

DESIGN AND CONSTRUCTION OF A WAILING ALARM SIREN SYSTEM ZUBAIR LARABA RAKIYA 200S/22108EE DEPARTMENT OF ELECTRICAL/COMPUTER ENGINEERING

UNIVERSITI PUTRA MALAYSIA INTEGRATING PUBLIC ART IN MALAYSIAN URBAN LANDSCAPE

Theatre Classification and Air Particle Count Is that Surveillance?

Guidelines for Ideal Layout for an Operating Theater Complex. Dr.R.D.Ravindran Aravind Eye Hospital Madurai

DESIGN OF AIR-CONDITIONING SYSTEM FOR SARS WARDS. By Yuguo Li and SARS Busters * Background

Performance Optimization of the Evaporative Condenser Design

PROPOSE AND DESIGN A CANVAS SHOES CLEANER MACHINE NUR SYAFIQAH BINTI ISMUINI

THE RELEVANCE OF TRANSIT-ORIENTED DEVELOPMENT FOR TRANSIT STATION COMMUNITY IN MALAYSIA ZAINUDDIN BIN AB RAHMAN

CONTEXT OF THIS AFRIKAANS PROTESTANT CHURCH

The Influence of Graphics on Contemporary Commercial Interiors in Sri Lanka. library UNIVERSITY OF MORATUWA, SRI LANKA MORATUWA

RDG 334 Theory and History of Design (Sejarah dan Teori Seni Reka)

LANDFILL SITE SUITABILITY USING GEOGRAPHIC INFORMATION SYSTEM AND ANALYTICAL HIERARCHY PROCESS

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Independent Lab Comparison of Electronic Air Cleaners

Senior Thesis Centre Community Hospital East Wing Addition - Proposal Keith Beidel Mechanical Option 12/05/02 1

PERFORMANCE OF FORCED CONVECTION EVACUATED TUBE SOLAR GRAIN DRYER. BOOKER ONYANGO OSODO B. Ed.(TECH); M. Phil (Tech. Ed) (J98/25749/2011)

UVC GERMICIDAL TECHNOLOGY APPLICATIONS IN HOSPITALS

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling

Transcription:

UNIVERSITI TEKNIKAL MALAYSIA MELAKA Control and Stabilize System for Temperature in Operation Theatre by Using Microcontroller This report submitted in accordance with requirement of the Universiti Teknikal Malaysia Melaka (UTeM) for the Bachelor s Degree in Electronics Engineering Technology (Industrial Electronics) with Honours by NURHANIS BT LOKMANULHAKIM B071110134 900817-07-5730 FACULTY OF ENGINEERING TECHNOLOGY 2015

UNIVERSITI TEKNIKAL MALAYSIA MELAKA BORANG PENGESAHAN STATUS LAPORAN PROJEK SARJANA MUDA TAJUK: Control and Stabilize System for Temperature in Operation Theatre by Using Microcontroller SESI PENGAJIAN: 2014/15 Semester 2 SayaNURHANIS BT LOKMANULHAKIM mengakumembenarkanlaporan PSM inidisimpan di PerpustakaanUniversitiTeknikal Malaysia Melaka (UTeM) dengansyarat-syaratkegunaansepertiberikut: 1. Laporan PSM adalah hak milik Universiti Teknikal Malaysia Melaka dan penulis. 2. Perpustakaan Universiti Teknikal Malaysia Melaka dibenarkan membuat salinan untuk tujuan pengajian sahaja dengan izin penulis. 3. Perpustakaan dibenarkan membuat salinan laporan PSM ini sebagai bahan pertukaran antara institusi pengajian tinggi. 4. **Sila tandakan ( ) SULIT (Mengandungimaklumat yang berdarjahkeselamatanataukepentingan Malaysia sebagaimana yang termaktubdalam AKTA RAHSIA RASMI 1972) TERHAD (Mengandungimaklumat TERHAD yang telahditentukanolehorganisasi/badan di TIDAK TERHAD manapenyelidikandijalankan) Disahkan oleh: AlamatTetap: No 1 Quarters Mardi, Kampung Padang Kangar, 32800, Parit Perak. Tarikh: Cop Rasmi: Tarikh: ** JikaLaporan PSM ini SULIT atau TERHAD, silalampirkansuratdaripadapihakberkuasa/organisasiberkenaandenganmenyatakansekalisebabdantem pohlaporan PSM iniperludikelaskansebagai SULIT atau TERHAD.

DECLARATION I hereby, declared this report entitled Control and Stabilize System for Temperature in Operation Theatre by Using Microcontroller is the results of my own research except as cited in references. Signature :. Author s Name : NURHANIS BT LOKMANULHAKIM Date : 23 DECEMBER 2014 iv

APPROVAL This report is submitted to the Faculty of Engineering Technology of UTeM as a partial fulfillment of the requirements for the degree of Bachelor of ElectronicsEngineering Technology (Industrial Electronics) with Honours. The member of the supervisory is as follow: (Project Supervisor) v

ABSTRAK Projek ini adalah untuk mengawal dan menstabilkan suhu di dalam bilik pembedahan. LM 35 akan diletakkan di dalam bilik pembedahan dan ia bertindak sebagai penderia suhu. Ia akan memberi isyarat kepada PIC16F876A untuk menghidupkankipas atau pemanas. Suhu yang diperlukan dikekalkan adalah sekitar 18 darjah Celsius hingga 22 darjah Celsius. Oleh itu, apabila LM 35 mengesan suhu minimum, pemanas akan bertukar ON sehingga suhu stabil dicapai. Kipas akan terus berfungsi. Walau bagaimanapun, apabila LM 35 mengesan suhu maksimum, ia akan menghantar isyarat kepada pengawal mikro. Oleh itu, pengawal mikro yang akan mengawal kelajuan kipas. Sistem ini juga akan melaksanakan teknologi baru bagi kaedah penyaman udara. Ais akan digunakan untuk bekalan udara yang sejuk di dalam bilik pembedahan. Oleh itu, kipas akan meniup ais untuk mengawal suhu. Sistem ini akan dikawal selia secara berterusan. vi

ABSTRACT This project is to control and stabilize the temperature inside operation theatre. LM 35 will be placed inside the operation theatre that acts as a temperature sensor. It will give a signal to PIC16F876A to trigger the blower or heater. The temperature that is needed to be maintained is around 18 degrees Celsius to 22 degrees Celsius. Therefore, once the LM 35 detects the minimum temperature, the heater will turn ON until the stable temperature is reached. The blower will continuously activate. However, when the maximum temperature is detected by the LM 35, it will sent signals to the microcontroller. Thus, the microcontroller will control the speed of the blower. The system also will implement a new technology for air conditioning method. Block of ice will be used for supply the cold air inside the operation theatre. Thus, the blower will blow the block of ice to regulate the temperature. The system will be regulated continuously. vii

DEDICATION To my beloved parents Mr. Lokmanulhakim Bin Basiron and Mrs. NorzainiBintiCheAmat thanks for your moral support. Besides that I would like to dedicate this project to my supervisor, Mr. IrNikAzran Bin Ab Hadi that assists me develops this project. I also want to thanks to my lecturers and friends that help me to develop this project. viii

ACKNOWLEDGEMENT I would like to thank to Mr. IrNikAzran Bin Ab Hadi for their guidance and constant supervision as well as for providing necessary information regarding the project and also for their support in completing the project. I would like to express my gratitude towards my parents and members for their kind co-operation and encouragement which help me in the completion of this project. My thanks and appreciations also go to my colleague in developing the project and people who have willingly helped me out with their abilities. ix

TABLE OF CONTENT Abstract Dedication Acknowledgement Table of Content List of Tables List of Figures List Abbreviations, Symbols and Nomenclatures ii iii iv v vi vii viii CHAPTER 1: INTRODUCTION 1 1.1 Background 1 1.2 Problem Statement 2 1.3 Objective 2 1.4 Scope of Project 3 1.5 Project Significance 3 CHAPTER 2: LITERATURE REVIEW 4 2.1 Introduction of Operation Theatre 4 2.1.1 Ventilation inside the Operation Theatre 5 2.1.1.1 Conventional Ventilation Systems for Operating Theatres 5 2.1.1.2 Mixing Ventilation 6 2.1.1.3 Parallel Flow Ventilation 7 2.1.1.4 Op-box Ventilation 9 2.1.2 Amount of the Particles inside the Operation Theatre 10 2.1.2 1 History of ISO 14644 11 2.1.2.2 ISO 14644-1 12 2.1.2.3 ISO 14644-2 13 2.1.3 Temperature inside the operation theatre 13 2.1.4 Comparisons between the Standard 15 x

2.2 Microcontroller 16 2.2.1 Microcontroller PIC 16F 16 2.3 Temperature Sensor LM 35 18 2.4 Previous Project 20 2.4.1 The Temperature Control System Using PLC 20 2.4.2 Room Temperature Controlling Using PIC 21 CHAPTER 3: METHODOLOGY 22 3.1 Project Development 22 3.2 Create a cording 24 3.3 Circuit Design 25 3.3.1 Proteus Software Design 26 3.3.2 Testing Circuit on Breadboard 27 3.3.3 PCB Developer Process 28 3.3.3.1 Step 1: Circuit printing 28 3.3.3.2 Step 2: UV Curing 28 3.3.3.3 Step 3: PCB Developer 29 3.3.3.4 Step 4: Etching 30 3.3.3.5 Step 5: Photoresist Stripper 31 3.3.3.6 Step 6: Drilling 32 3.3.4 Component Installation Process 32 3.3.5 Soldering Process 33 3.4 Hardware Implementation 33 3.5 Project Overview 38 3.6 Flow of the process 40 3.7 Gantt Chart 41 CHAPTER 4: RESULT AND DISCUSSION 42 4.1 Result 42 4.1.1 LCD Display 43 4.1.2 Redesign Hardware Implementation 44 4.2 Analysis 45 xi

4.2.1 Time Analysis 46 4.2.2 Quantity and Type of Ice Analysis 48 4.2.3 Distance of Temperature Sensor Analysis 49 4.2.4 Distance Path Travel Ice Analysis 50 4.2 Discussion 52 CHAPTER 5: CONCLUSION & FUTURE WORK 54 5.1 Conclusion 54 5.2 Future Work 55 REFERENCES 56 APPENDICES A Gantt Chart B Program Coding xii

LIST OF TABLES 2.1 The ISO 14644 Series 11 2.2 ISO 14644-1 Cleanroom Standards 12 2.3 Required testing (ISO 14644-2) 13 2.4 Optional testing (ISO 14644-2) 13 2.5 Desripition of Pin LM35 19 2.6 Difference between PIC and PLC 20 4.1 Data Collection within 1 Hour 47 4.2 Quantity and Type of ice corresponding to the time 49 4.3 Sensitivity of Temperature Sensor 49 xiii

LIST OF FIGURES 2.1 The Operation Theatre 4 2.2 Mixing Ventilation 7 2.3 Horizontal Parallel Flow Ventilation 8 2.4 Vertical Parallel Flow Ventilation 9 2.5 Op-box Ventilation 10 2.6 Pin Diagram PIC 16F876A 18 2.7 LM35 19 3.1 Flowchart of project development 23 3.2 The main function of the coding 24 3.3 Process flowchart of making PCB board 25 3.4 Schematic Drawing of the circuit 26 3.5 ARES PCB Layout 27 3.6 UV Curing Machine 29 3.7 PCB Developer Process 29 3.8 Etching Machine 30 3.9 After Etching Process 30 3.10 Photoresist Stripper Process 31 3.11 After Process of Photoresist Stripper 31 3.12 Drilling Process of the PCB Board 32 3.13 The Cooling System Box 33 3.14 The Operation Theatre Box 34 3.15 Installation of Heater Pad 34 3.16 Installation of Temperature Sensor 35 3.17 Installation Path of Ice 35 3.18 Installation of the Blower Fan 36 3.19 Installation of Piping 36 3.20 View inside the Controller Box 37 3.21 Overall view of the Controller Box 37 xiv

3.22 Overview of Project 38 3.23 Flowchart of the Project Process 40 4.1 Condition of temperature equal or more than 23 C 43 4.2 Condition of temperature between 23 C until 19 C 43 4.3 Condition of temperature less than 19 C 43 4.4 LCD display the first data reading 44 4.5 LCD display the data reading after 5 minutes 44 4.6 LCD display the data reading lowest than minimum range 44 4.7 Previous Hardware Implementation 45 4.8 Latest Hardware Implementation 46 4.9 Graph Time versus Temperature within 1 Hour 48 4.10 Previous path of ice 51 4.11 Latest path of ice 51 xv

LIST OF ABBREVIATIONS, SYMBOLS AND NOMENCLATURE ACH -Air Change per Hour ASHRAE -American Society of Heating, Refrigerating and Air-Conditioning Engineers C -Celsius Cm -Centimeter IDE -Integrated Development Environment FED -Federal LAF -Laminar Air flow LCD -Liquid Crystal Display MOH -Ministry of Health MPLAB -Microprocessor Laboratory OT -Operation Theatre PCB -Printed Circuit Board PIC -Peripheral Interface Controller PLC -Programmable Logical Controller SD -Standard V -Volt -Degree % -Percentage xvi

CHAPTER 1 INTRODUCTION This chapter presents the overview for overall description for this project. Thus, it is including the background of project, objective and scope. The organization of the report also state in this chapter for the preview of the report ahead. 1.1 Background Operation theatres require special attention in terms of air ventilation, temperature, and humidity. This is because, any negligence can come right side-effects. The temperature inside the operation theatre needs to be controlled because it can influence three main requirements which is avoided humidities that can contribute to the risk of infection to the patients, to conserve the patient resource, and last promote the comfort and working efficiency of the staff. For example, the humidity inside theatre should be maintained between 50 to 60%. One of the reasons this requirement needs to be met is that if the percents humidity in the room exceeds 60% chance of bacteria / fungi exist will be higher. If the percentage of humidity to be 78% of the bacteria already exist and fungus will occur. Other than that, when the temperature was uncontrolled it can contribute to the non-effective working environment which can affect the concentration of the team. Besides that, stable temperature should be emphasized because if the temperature dramatically decrease or increase it can affect the patient. The low temperature can cause bacteria breeding while the temperature is 1

too high can cause complication to post-operative patients. Therefore, one new system to be introduces. This system is able to control and stabilize the temperature in the operating room. Besides that, it is an interesting point where the system will use different method of air conditioning. Instead of using air conditioner, this system will used a block of ice for supply the cold air through the operation theatre. Therefore, the temperature in the operating theater is very important to ensure a smooth process surgery. 1.2 Problem Statement Nowadays temperature system introduce in the hospital is good and follow the standard requirement given by the government. However, to maintain the temperature in this range is normally dealing with failure. Normally the hospital gives a negative feedback regarding the temperature. The temperature inside the operation room usually cannot be control. When the surgery take too long and it contribute with many people, the temperature inside the room will rise down. The temperature is not in range between 18 C to 22 C as standardize by Ministry of Health (MOH). This unfavorable temperature will give a side affect toward working environment of the surgery team. In addition, when the temperature is uncontrolled it can cause the infection toward the patient. The temperature that is too low can lead to wound breakdown. This complication can occur to patients, especially patients who have just finished the surgery process. Further than that, the room temperature will affect the stability of the patient especially for those just finish their surgery. So, if the room is too cold it will make the patient is in an uncomfortable situation thus will potentially other diseases such as hypothermia. 2

1.3 Objective The objectives of this project are to: To implement a new method of technology. To stabilize the temperature inside operation theatre using blower and heater. 1.4 Scope of Project This research will cover on designing one system that can control and stabilize temperature inside the operation theatre. Besides that, this system also will implement a new method system. Instate using air-condition, the system will apply a block of ice for supplying cool air toward operation theatre. Other than that, the research will cover on the operation of PIC16F876A microcontroller. This controller will trigger either heater or blower for stabilize the room. In addition the scope also is focus on the application of temperature sensor for detecting the surrounding temperature. 1.5 Project Significance It is expected to build up one system that can control and stabilize the temperature inside operation room by using the PIC16F876A microcontroller. Other than that, this system will automatically run and it also will implement new method technology which is supply cold air using block of ice. This project can give benefic toward the operation theatre because it can overcome the problem regarding the temperature. 3

CHAPTER 2 LITERATURE REVIEW A literature review is a body of text that aims to review the critical points of current knowledge for any related information so as to enhance the understanding of the concept and certain terminology which is used throughout this research. 2.1 Introduction of Operation Theatre Figure 2.1: The Operation Theatre 4

Operation theatre was a room for performing a surgery. In the operation theatre there has table and chair at the centre of the room. The team involve with the operation theatre are surgeons and nurses. The surgeons will wear street clothes with an apron to protect them from blood stains. The operation will be handling with unsterilized instruments, hand-threaded needles. Operation theatre can be class into two categories. First categories is superspecialty operation theatre while second once is general operation theatre. Superspeciality operation theatre conducts operations of Neurosciences, Orthopedics (Joint Replacement), Cardiothoracic and Transplant Surgery (Renal, Liver). General operation theatre includes Ophthalmology and all other basic surgical disciplines. District hospital operation theatre and FRU operation theatre would fall under this category. When handle with operation theatre, there are many things that need to take a serious look. This is because, in this room it will involve with the person life. So that, five mains things that need to be consider while built up the operation theatre. The five main things are: (a) ventilation of the room (b) amount of particle contains (c) temperature needed (d) humidity (e) pressure inside the room However, there are too many standard guidelines in the world regarding the operation theatre. We in Malaysia use the British Medical Council as the references to organize our own standard that been provided by Ministry of Health (MOH). 2.1.1 Ventilation inside the Operation Theatre Ventilation is important in all occupied hall. The requirements of ventilation are determined in some factors such as fresh air supply for human life, control of 5

airborne bacteria, thermal comfort, and humidity level. The ventilation system is considered as the main contributor to the efficiency and function of an operating theatre. Level of comfort and level of airborne contaminant need to be control because patients wound after surgery easily get infection. Thus, the planning and designing of ventilation systems in operating theatres is crucial so that both infection rates and operating costs are lowered. Based on the journal written by Agne Nilsson (2002), there are many types of ventilation system has been practice for operation theatre. From the journal he had conclude some ventilation system regarding his study. 2.1.1.1 Conventional Ventilation Systems for Operating Theatres There are various ventilation systems that have been designed and installed in the operating theatre. Normally, the designed and installed was classifies into two main categories which is mixing ventilation and parallel flow ventilation. 2.1.1.2 Mixing Ventilation The operation of the mixing ventilation is based on the principle of air supply mixed with the existing air inside the room. The supply air normally located at the symmetrically on the ceiling. The results of this type of ventilation by Anderson, P.A (1983) prove that the airflow is fairly unstable. The air direction is uncontrolled. Based on the studies make by Anderson, P.A (1983), the area around the operation table received trace concentration twice higher compare to the other areas in the room. Therefore, it shows that the mixing ventilation is ineffective to ventilate away anesthetic gas and odors. 6

Figure 2.2: Mixing Ventilation 2.1.1.3 Parallel Flow Ventilation The parallel flow ventilation operates based on the principle that supply air is conducted parallel through the room. The parallel flow ventilation systems can be horizontal or vertical flow. They have been used as conventional ventilation for operating theatres. Parallel flow ventilation is also commonly referred to as Laminar Air Flow system whereby the laminarity or uni-directionality of the air flow is said to exist in the operating theatre. H. Laufman from the Institute for Surgical Studies, Montefiore Hospital and Medical Centre, New York, once debated that laminar air flow cannot be achieved in an actively used operating theatre. In 1982, it has been reported by E.A. Salvati, M.D., Journal of Joint and Bone Surgery, 1982, that horizontal parallel flow ventilation systems are proven to be susceptible to contamination of the upstream air flow by the medical staff and surgical team with consequential increase in wound infection. To reduce the risks, the only option is to build physical barriers, which would defeat the purpose for an ergonomic layout in the operating theatre. 7

To further worsen situation, the horizontal supposedly uni-directional air flow would be disturbed by convection up-currents, thus generating turbulence and entrainment of contaminants. Figure 2.3: Horizontal Parallel Flow Ventilation Vertical parallel flow ventilation or commonly known as laminar air flow (LAF) system is a widely acceptable ventilation system used in hospitals and other healthcare facilities. These systems were very common in the sixties and seventies particularly for joint replacement surgeries. There are major drawbacks for this particular type of ventilation system. Both the installation and operating costs for this system are high. In order to achieve a low bacterial count (cfu/m3), LAF systems have to produce as high as 400 air changes per hour (ACH). Some LAF systems even produce up to 800 ACH. If the sedimentation processes for the room balance were disregarded and the inverse proportionality relationship between bacterial count and ACH is assumed, then a low bacterial count can only be achieved with the expense of high operating costs. LAF systems also commonly have 8-12 filters to cover the entire ceiling mounted diffusion system to ensure all the supply air is filtered before it enters the operating theatre. This has added unnecessary first costs during installation. 8

Figure 2.4: Vertical Parallel Flow Ventilation 2.1.1.4 Op-box Ventilation In 1960s and 1970s, Professor J. Charnley, UK, state that the infection rate could be reduced from 7% to 0.5% by performing hip replacement surgery in an op-box ventilation system. However, all surgeons and medical staff had to wear tightly sealed surgical garments and masks with a special extraction system to achieve this result. Strict work discipline was also an influencing factor to prevent unnecessary vortex formation, which may convey bacteria to the sterile areas. These op-box systems have physical barriers such as curtains or wall systems built surrounding the surgical team. These systems therefore were popularly known as op-boxes. The major drawbacks for these systems are that surgeons suffered from poor mobility, poor visual contact because of misting on the hoods and poor communication through the hoods. 9