Operating Instructions MXL Multi-Line Keyboard/Display Panel

Similar documents
Installation Instructions Model SSD-C-REM

Fire Safety. Installation Instructions Model SMB-2 Main Control Board OPERATION INSTALLATION

Fire Safety. Installation Instructions. Model RCC-2/R and RSE-1 Remote Control Centers OPERATION INTRODUCTION INSTALLATION

Section 9 System Operation

Technical Manuals Online! A B C DEF GHI JKL POWER 9 0 COMMAND YZ. User's Guide

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

Section 8 System Operation

Fire Safety. Installation Instructions Model MMB-2 Main Control Board OPERATION. INSTALLATION Always remove power before installation.

user manual Document No , Revision 03 November 2015

SFC-200 SERIES LED FIRE ALARM PANEL

Cerberus TM PRO Fire Safety System A comprehensive fire-protection system

FA-300 Series. LED Fire Alarm Control Panel. User Guide. FA-300 SERIES Fire Alarm Control Panel. FA-300 SERIES Fire Alarm Control Panel

Operator s Manual Part: InfoAlarm Product: 4100U, 4100ES Rev. B

FIRE FIRE. 4100U Fire Alarm. Operator's Manual. Technical Manuals Online! -

MXL-IQ CONTROL PANEL. Operation, Installation, and Maintenance Manual. Siemens Industry, Inc. Building Technologies Division Florham Park, NJ

Desigo TM Fire Safety System A comprehensive fire-protection system

CONTENTS Installation Precautions... 1 Chapter 1 Product Introduction... 2 Chapter 2 Technical Specifications... 3

FMR Installation Instructions. Addressable Fire System Controller

Intelligent Security & Fire Ltd

Cerberus PRO A comprehensive fire-protection system

AND ARCHITECT SPECIFICATIONS

Desigo TM Fire Safety System A comprehensive fire-protection system

2000 Series. Program Entry Guide. Control Panels

Fire Safety. Installation Instructions. Model ADBX-11. Audible Base INTRODUCTION. Model ADBX-11

TrueAlarm Fire Alarm Systems

OPERATOR S MANUAL MR-2100/2200. Fire Alarm Control Unit. Revision 0 Document #: LT-2002

Fire Command Center. XR2400F User s Guide

Fire Operator Workstation (Fire OWS) User s Guide

Document No Issue 4 user manual

Testing the System. Battery Test. Dialer Test. Fire Drill Test (Code + [#] + 69) One-Man Fire Walk-Test (Code + [#] + 68)

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide

Fire detection and alarm system Operating instructions

MMX TM. Intelligent Fire Alarm Network. User Guide

FieldServer Driver - Serial FS SBT-FSI (Siemens Building Technologies Foreign Systems Interface)

FIREFINDER-XLS CONTROL PANEL

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

Fire Command Keypad. XR5 User s Guide

U ser's Guide PC6010

Area Systems While the alarm bell or siren is sounding, enter your user code. The system silences the alarm bell or siren.

Michigan State University Construction Standards FIRE DETECTION AND ALARM PAGE

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX

MIR2. System Operations Manual. P/N Rev 1.5 OCT98

D1255RB/D1256RB/D1257RB

XR10 Command Processor Panel Programming Guide

AFP-300/400 OPERATORS MANUAL INTELLIGENT FIRE DETECTION AND ALARM SYSTEM SOFTWARE VERSION 2.2 REVISION AUS 3

CSP-204 CSP-208 CSP-104 CSP-108

FX-350/351 Series. Analog/Addressable Fire Alarm Control Panel. User Guide

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

Marine Fire Detection System Manual MXL Control Panel

FireSeeker Fire Alarm Control Panel Model FS-100 Installation, Operation, and Maintenance Manual

FIREFINDER-XLS CONTROL PANEL

Advanced Protection System

D6500 reports are shown in typewriter style letters. For example, AC FAILED indicates the report sent when the panel reports an AC power failure.

Master User Guide. Premier 412/816/832. Issue 8

Installation Instructions. Fire Command Center/Fire Alarm Annunciators D1256/D1257

Independent Zone Control (I.Z.C.)

NETWORK FIRE ALARM CONTROL PANEL. Features

Control Panel User Guide (TO BE RETAINED BY THE USER)

Laptop / PC Programming Manual

PROGRAMMING GUIDE XRSUPER6/XR20/XR40 COMMAND PROCESSOR PANELS

HS-5100, HS-5200, HS-5400 ANALOGUE ADDRESSABLE CONTROL PANELS. User Manual. Approved Document UI-ELAN-02 Revision 03

QS1 Technical Reference Manual P/N REV 05 REB 14FEB13

Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual

ALARM SYSTEM USER S MANUAL Rev

QS1 Technical Reference Manual P/N REV 05 REB 14FEB13

OPERATING GUIDE for your GEMC-BK1 KEYPAD

MPC-6000 / MPC-7000 / RND-2

INTELLIGENT FIRE ALARM CONTROL PANEL

i on Compact Security System

D1265. User's Guide. Touchscreen Keypad

ARCHITECT AND ENGINEER SPECIFICATIONS

Operator's Handbook. Release 3. Fire Alarm Control Panel, BS-310 / 320 / Operator Panel BS-330. System Program Version 3.8.0

FX-350/351/353 SERIES

USER'S GUIDE FA1220CV. 2-Partition Security System N7003-1V2 7/98

HARDWIRED CONTROL PANELS

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

2000 SERIES DIAGNOSTIC ALARM CONTROL SYSTEM

MG5000 V2.4 MG5050 V2.4 SP5500 V2.4 SP6000 V2.4 SP7000 V2.4. Programming Guide

Fire Alarm Control Panel AFP Operations Manual. Australian Edition. Document DOC /11/2015 Rev: P/N DOC :B

HCA Series Conventional Fire Alarm System (HCA-2, HCA-2D, HCA-4, HCA-4D, HCA-8, HCA-8D) Installation and Operation Manual

VISTA-100 Commercial Fire & Burglary Partitioned System

2200 and 2200L ALARM CONTROL SYSTEMS

Operating instructions SENTRI4 Control panel based Fire detection and alarm system

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Installation Instructions Model DLC

Installation Instructions Model HZM

MXL/MXLV 19 Rack Mount Equipment

TX3 Series TELEPHONE ACCESS SYSTEMS. Programming Manual

Fire control panels FC360

AGRI-ALERT 9600 ALARM SYSTEM USER MANUAL

Conventional Releasing Control Panel

RAM-3500-LCD. Remote Annunciator. Installation and Operation Manual

FX-350/351 SERIES. Analog/Addressable Fire Alarm Panel. Programming Manual

VISTA-50P VISTA-50PUL

MR-2350/2351 Series Analog/Addressable Fire Alarm Panel

Elite 64 Version 64 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

$'(0&2 9,67$ 3DUWLWLRQHG 6HFXULW\ 6\VWHP 8VHU *XLGH N7003V3 5/04 Rev A

FX Intelligent Analog Fire Alarm Control Panel. Installation and Operation Manual

OPERATING GUIDE for your GEM-RP1CAe2 KEYPAD

Transcription:

Operating Instructions MXL Multi-Line Keyboard/Display Panel Local Mode Operation TRODUCTION When the MXL Keyboard/Display Panel is installed in a control panel, the components are behind a locked door. Unlock and open the door to gain access to the keys and controls. THE DISPLAY The ¼ VGA display allows the user to view up to 8 lines of events and 1 complete system status line at the same time. The ninth line of the screen is a fixed line that is located below the 8 listed events that are visible, and holds the highest priority unackowledged event. What is shown on the display depends on the current state of the System. If your system is set for Canada, the oldest event appears in the first line of the display. If your system is set for the United States, the most recent event appears in the first line of the display. Line 10 contains the system status information which is grouped by event type. Lines 11 and 12 normally display the System messages, date and time. This area on the display functions like the MKB-1/-2/-/-4 two-line display. Press ENTER to activate the MXL menu options. 1 2 4 5 6 7 8 9 10 11 12 SIEMENS FIRE SAFETY APP : RX.X.X Lines 1, 14 and 15 are used to display more information on a particular event when the user presses the MORE FO key. The System has several displays. When the System is first powered on it displays a screen similar to the one shown in Figure 1. 1 14 15 Example shown is Canadian Display Figure 1 MXL Keyboard/Display in Start-up Mode Siemens Building Tec echnologies

All examples in this document are given for the Canadian display. When the system is in Normal mode, the display is similar to the one shown in Figure 2. 1 2 4 5 6 7 8 9 10 ALR=000, SUP=000, TBL=000, SEC=000 11 SIEMENS BUILDG TECHNOLOGIES 12 12:22:22 Oct 22, 02 1 14 15 (000 / 000) Example shown is Canadian Display Figure 2 MXL Multi-Line Display in Normal Mode When events are annunciated, the system goes into Active mode. The display for Active mode is similar to the one shown in Figure. After 90 seconds of panel inactivity, (i.e., no additonal incoming events or user interface activity), the screen will change and display the oldest event for Canada and the most recent event for the United States in the first line. When the system is set for the United States, there may appear to be a delay in the reporting of events. This is because the most recent event is placed at the top of the event list. It might be necessary to scroll to the top of the list to view the most recent event. 2

40 Characters 1 TBL BELL #1 (IAC 1) (main) Highlight 2 TBL PUT LOOP 2, DEVICE #2 TBL PUT LOOP 2, DEVICE #1 4 TBL PUT LOOP 2, DEVICE #4 Custom Message Event Type 5 6 TBL PUT LOOP 2, DEVICE #5 TBL PUT LOOP 2, DEVICE #6 ACK Status 7 TBL PUT LOOP 2, DEVICE #7 ACK 8 9 TBL PUT LOOP 2, DEVICE #8 TBL BELL #1 (IAC 1) (main) OUT ACK Highest Priority Unacknowledged Event System Message Event Address Queue Event # Event Time/Date 10 11 12 1 14 15 ALR=000, SUP=000, TBL=017, SEC=001 SIEMENS BUILDG TECHNOLOGIES 12:22:22 October 22, 02 2-001 Audible Loop 007 Signal Circuit Loop Open 21:22:22 Oct 21, 01 (007 / 018) System Status Line Current Time/Date Device Type TBL Type Event # Total # of Events Example shown is Canadian Display Figure MXL Multi-Line Display in Active Mode As an example, when a trouble event is annunciated the System places the event on the display according to its priority or queue (Alarm, Supervisory, Trouble, then Security) in the format: [Event Type] [Custom Message] [/OUT] [ACK STATUS or BLANK]. The system status in line 10 is also updated to reflect the newest event. ACK appears in the display if the event has been acknowledged; otherwise, the field is blank. is displayed when an event occurs; OUT is displayed when a normal state is restored. To view information about a previous event, press the UP ( ) or DOWN ( ) keys located next to the MORE FO key to scroll to the desired event and highlight it, then press the MORE FO key. Lines 1, 14 and 15 will display the event information in the following format: [event address] [device type] [event number in queue] [event type] [event time/date] [event number in all queues] [total number of events]

DISPLAY KEYS The Multi-Line Display has three display keys, UP ( ), DOWN ( ) and MORE FO, which are located on the MKB, as shown in Figure 4. Press the DOWN key to scroll down the items in the list one event at a time. The DOWN key only works when scrolling the first eight lines of the display, it does not scroll to the fixed event on line nine. This key enables the user to view the list of events that are off-screen. The screen will stop moving down once the end of the list is reached. Press the UP to scroll back up to the top of the list of events. The UP key only works when scrolling the first eight lines of the display, it does not scroll to the fixed event on line nine. This key enables the user to view the list of events that are off-screen. The screen will stop moving up once the top of the list is reached. Press the MORE FO key after highlighting an event using the UP and DOWN keys to display the basic event information on the screen, including the event number, address, time/date, and device type or trouble type. When used together with the numerical keypad, the MORE FO key can be used to jump to the top of any event queue. For example, to reach the first event in the Alarm queue, press and hold MORE FO and then press 1 on the numeric keypad. (1= Alarm, 2=Supervisory, =Trouble, 4=Security.) POWER ALIMENTATION PARTIAL SYSTEM DISABLED PLUS D'FO MORE FO ` SYSTÈME PARTIELLEMENT HORS SERVICE ALARME ACC AUD SIL SURV. ACC PANNE ACC SEC ACC ALARM ACK AUD SIL SUPV ACK TRBL ACK SEC ACK RESET RÉENCL. FUNCTION/ ALT 1 FUNCTION/ ALT 2 FUNCTION/ FONCTION FONCTION FONCTION ABC 1 2 GHI JKL 4 5 DEF MNO 6 HELP/ AIDE PRT/ IMP. ALT 1 F1 F2 PQRS 7 * TUV WXYZ 8 9 0 # ENTER/ ENTRER SPACE/ ESPACE CLEAR/ EFFACER ALT 2 F F4 Figure 4 The MKB Keyboard/Multi-Line Display Panel (Canadian Model is Shown Here) 4

System Control Keys The System Control Keypad is described in the table below: Key ALARM ACK AUD SIL SUPV TRBL ACK ACK SEC ACK MORE RESET FO Purpose SYSTEM CONTROL KEYPAD To acknowledge a fire alarm To silence or unsilence a notification appliance circuit To acknowledge a supervisory To acknowledge a trouble To acknowledge a security condition To view all information about an event. When used together with the numerical keypad (1, 2,, 4), the operator can jump to the top of any event queue. For example, to reach the first event in the Security queue, press and hold down MORE FO and press 4 on the keypad. To reset the System System Control LEDs When lit, the LEDs (light-emitting diodes) indicate the conditions described in the following table: AUDIBLES LED ALARM SILENCED SUPERVISORY Indicates SYSTEM CONTROL LEDS Flashes when there is a least one unacknowledged alarm; glows steadily when all fire alarms are acknowledged. fire For U.S. systems, flashes when at least one notification appliance circuit (NAC) is active; glows steadily when all silenceable NACs are silenced until system is reset. For Canadian systems, only turns on when audibles are silenced. Flashes when there is at least one unacknowledged supervisory; glows steadily when all supervisories are acknowledged. T ROUBLE Flashes when there is at least one unacknowledged trouble; glows steadily when all troubles are acknowleged. SECURITY Flashes when there is at least one unacknowledged security condition; glows steadily when all security conditions are acknowledged. P OWER Indicates the power is on. Steady glow = AC power. Flashing On = battery backup. PARTIAL SYSTEM DISABLE At least one device is disabled. 5

Addresses Fixed Addresses All modules and devices annunciated on the MXL are identified by an address (MMM-DDD). Each address is in two parts: a module address (MMM) and a device address (DDD). The number identifying the module may be as high as 25, and the number identifying the device may be as high as 254. Enter all leading zeros for module and device addresses or use the SPACE key to eliminate the need to enter the leading zeros. For events specific to a module, the device address is not required. A module may be assigned to any address on the System, except for some fixed addresses that have already been assigned. (See the Fixed Module Addresses Table.) The modules communicate to the MXL Control Panel through a serial communications network called MNET. The System continuously supervises all of the modules for presence and proper operation. You may assign a module to any address on the System, and assign addresses in any order, mixing different types of modules and leaving gaps in the numbering, provided you do not use the fixed addresses. Module Address FIXED MODULE ADDRESSES Module Device Address (Range) 0 Do Not Use 1 Analog loop 1 (MMB-1/-2) 001-060 2 Analog loop 2 (MMB-1/-2) 001-060 248 MKB 249 MKB 250 MKB 251 MKB, No. 1 252 Reserved 25 MMB(SMB)-1/-2 001 to 250 254 Programmer CSG-M 255 Global (reserved) The following modules occupy an address on the System, but have no devices (and no device addresses). MKB NET-7 RCC-1/-2/- RCC-1F/-2F/-F CMI-00 RCM-1 NIM-1W/-1R Numeric Keypad Use the numeric keypad (keys 0 through 9) when the System asks for a module number, device number, password, time, date, or other information. The display shows each number as you press the key (except when you enter a password the System shows an asterisk for each digit that you type). 6

Command Keypad The command keys are described in the following table: Key ENTER Purpose COMMAND KEYPAD Select the item to the left of what is flashing the display (unless entering a number). Select the item to the right of what is flashing the display (unless entering a number). Go back to the previous item. on on Press to select the item on which the cursor is flashing. After typing in numbers, press ENTER to complete the entry. H ELP Press to display a one-line message. P RT Press to begin printing various lists and reports. SPACE CLEAR Press to eliminate the need to input "0" multiple times. For example, to input the address 001-010, enter 1 SPACE 10 SPACE and ENTER. Press to cancel printouts begun by pressing PRT. The System will print: This listing prematurely terminated. The ALT and Function Keys Using the four function keys alone or in combination with ALT1 or ALT2 provides a total of 12 special functions. When using a combination, hold the ALT key down and then press the function key. F1 ALT1+F1 ALT2+F1 F2 ALT1+F2 ALT2+F2 F ALT1+F ALT2+F F4 ALT1+F4 ALT2+F4 These keys are defined using the CSG-M Custom Software Generator (See the CSG-M Programming Manual, P/N 15-09081). Internal Audible Alarm The internal audible alarm sounds steadily when there is an unacknowledged alarm. It pulses if all alarms are acknowledged but there is at least one supervisory, trouble, or security condition. PRT and CLEAR Keys If your System includes the printer option, the printer automatically prints System events. Either an external serial or parallel printer can be connected. To select the printer port, refer to the CSG-M Programming Manual, P/N 15-09081. The multi-line display cannot be connected to a TSP-40 strip printer. The PRT key is used to print various lists and reports. To cancel the printing at any time, press the CLEAR key; the System will print the following message:. 7

Modes Of Operation The MXL alphanumeric display annunciator has five modes of operation: 1. Alarm 2. Supervisory. Trouble 4. Security 5. Normal This order ensures that alarms always take priority over all other conditions. In turn, supervisories always take priority over troubles and troubles always take priority over security conditions. All of the above modes take priority over Normal mode. Normal Mode Normal mode is the absence of any alarms, supervisories, troubles, or security conditions. In Normal mode, the display will look similar to the one shown in Figure 2 on page 2. The POWER LED glows steadily in Normal mode when the System has AC power. The ALARM, AUDIBLE SILENCE, SUPERVISORY, TROUBLE, SECURITY, and PARTIAL SYSTEM DISABLE LEDs are off and the internal audible is off. If your System has the printer option, the System prints a message in the following format every day at midnight, even when there are alarms or other conditions: Alarm Responding to an Alarm Follow the response plan approved by the local authority having jurisdiction. When the MKB is installed, the ACKnowledge key and audible Alarm Silencing key (AUD SIL) on the MKB are behind a locked door. To acknowledge an alarm or trouble, or to silence an audible alarm, first unlock and open the door. Alarm Annunciation When a fire is detected, the System causes the ALARM LED on the MKB to flash, the System s internal audible to sound and the display on the MKB to display the event in the format shown in Figure 5. When the country setting is US, the AUDIBLE SILENCE LED flashes. 8

40 Characters 1 ALM CUSTOM MESSAGE ACK 2 ALM CUSTOM MESSAGE 4 5 6 7 8 9 ALM CUSTOM MESSAGE 10 ALR=002, SUP=000, TBL=000, SEC=000 11 SIEMENS BUILDG TECHNOLOGIES 12 12:01:01 Dec 1, 02 1 1-001 ID-60I Ionization Detector 14 002 15 11:59:59 Dec 1, 02 (002 / 002) Example shown is Canadian Display Figure 5 ALARM Event Screen With More Info Key Pressed In addition, the System responds to alarms with programmed output functions such as other audible signals. In Figure 5, 1-001 represents the address of the device reporting the alarm. On the display, not all leading zeros are shown. If your System includes a printer, note that the leading zeros are not shown. 002 on Line 14 in the More Info area (Lines 1-15) tells you that this is the second (and the most recent) of two alarms received. The status information shown in Line 10 reports the total number of alarms, supervisories, troubles, and security conditions. 9

If your System includes a printer, it prints a message from two to four lines long similar to the following: In the above printed message, ALARM indicates that the type of event is an alarm; 1-1 is the device address; #2 is the number of the alarm in the list of alarms; [custom message] is a custom message entered using the CSG-M Custom Software Generator (See the CSG-M Programming Manual, P/N 15-09081); [device type] is the type of device which reported the alarm. Viewing the List of Alarms To see the alarm list when there are more than eight alarms, press the DOWN key on the MKB. (If your system is set for Canada, the system displays the oldest alarm first.) How to Individually Acknowledge an Alarm (NFPA 72 Proprietary, UL 1076) The first unacknowledged alarm is placed on line nine of the display. Press ALARM ACK to acknowledge the alarm. The System acknowledges the first alarm displayed and then places the second unackowledged alarm in line nine (the fixed line). If your System has the printer option, it prints an alarm acknowledgment message similar to the following: Note that the acknowledgment message includes the term ACK to indicate this alarm was acknowledged. Continue acknowledging alarms as explained above until the System displays the following message on Line 11: ALL ALARMS ACKNOWLEDGED The ALARM LED glows steadily to indicate that all alarms are acknowledged. If there are no supervisories, troubles, or security conditions still in the System, the internal audible goes silent; if any of those conditions still exist, the internal audible pulses. If your System includes a printer, it prints a message similar to the following: 10

How to Block Acknowledge an Alarm (NFPA 72 Local, 72 Municipal Tie, 72 Remote Station) Note the specific location of the alarm(s) by using the procedures described above. Unlock and open the door. Press ALARM ACK to acknowledge all alarms. The System displays the following message: ALL ALARMS ACKNOWLEDGED If your System includes the printer option, it prints the following message: If you press ALARM ACK again, the System displays: ALL ALARMS ACKNOWLEDGED The ALARM LED glows steadily to indicate that all alarms are acknowledged. If there are no supervisories, troubles, or security conditions in the System, the internal audible goes silent; if any of those conditions still exist, the internal audible pulses. Silencing the System Press AUD SIL after all alarms are acknowledged. The System displays the following message: AUDIBLES SILENCED (Pressing AUD SIL a second time causes the internal audible and the System to unsilence and the message AUDIBLES UNSILENCED to appear on Line 11 of the display; thus, pressing AUD SIL alternately silences and unsilences the System.) If your System has a printer, it prints a message similar to the following: 11

Supervisory Supervisory Annunciation When a supervisory is detected, the System causes the SUPERVISORY LED on the MKB to flash, the System s internal audible to sound, and the display on the MKB to display the event in the following format: 40 Characters 1 SUP CUSTOM MESSAGE 2 SUP CUSTOM MESSAGE 4 5 6 7 8 9 SUP CUSTOM MESSAGE 10 ALR=000, SUP=002, TBL=000, SEC=000 11 SIEMENS BUILDG TECHNOLOGIES 12 12:01:22 Dec 1, 02 1 1-001 14 002 15 11:59:59 Dec 1, 02 (002 / 002) Example shown is Canadian Display Figure 6 SUPERVISORY Event Screen With More Info Key Pressed In addition, the System responds to supervisories with programmed output functions. In Figure 6, 1-001 represents the address of the device reporting the supervisory. 002 on Line 14 in the More Info area (Lines 1-15) tells you that this is the second (and the most recent) of two supervisories received. The status information shown in Line 10 reports the total of alarms, supervisories, troubles, and security conditions. If your System includes a printer, it prints a message from two to four lines long similar to the following: 12

In the above printed message, SUPERV indicates that the type of occurrence is a supervisory; 1-1 is the device address; #2 is the number of the supervisory in the list of supervisories; [custom message] is a custom message entered using the CSG-M Custom Software Generator (See the CSG-M Programming Manual, P/N 15-09081); [device type] is the type of device which reported the supervisory. Viewing List of Supervisories To see the supervisory list when there are more than eight supervisory events, press the DOWN key on the MKB. (In systems set to Canada, the system displays the oldest event first.) How to Individually Acknowledge a Supervisory (NFPA 72 Proprietary, UL 1076) The first, unacknowledged, supervisory is placed on line nine of the display. Press SUP ACK. The System acknowledges the supervisory displayed and then places the second, unackowledged supervisory in line nine (the fixed line). If your System has the printer option, it prints an acknowledgment message similar to the following: Note that the acknowledgment message includes the term ACK to indicate this supervisory was acknowledged. Continue acknowledging supervisories as explained above until the System displays the following message: ALL SUPERVISORIES ACKNOWLEDGED The SUPERVISORY LED glows steadily to indicate that all supervisories are acknowledged. If there are no troubles or security conditions still in the System, the internal audible goes silent; if any of those conditions still exist, the internal audible pulses. If your System includes a printer, it prints the following message: How to Block Acknowledge a Supervisory (NFPA 72 Local, 72 Municipal Tie, 72 Remote Station) Note the specific location of the supervisories by using the procedures described above. Unlock and open the door. Press SUP ACK to acknowledge all supervisories. The System displays the following message: ALL SUPERVISORIES ACKNOWLEDGED If your System includes a printer, it prints the following message: If you press SUP ACK again, the System displays: ALL SUPERVISORIES ACKNOWLEDGED 1

The SUPERVISORY LED glows steadily to indicate that all supervisories are acknowledged. If there are no troubles or security conditions in the System, the internal audible goes silent; if any of those conditions still exist, the internal audible pulses. Trouble Trouble Annunciation When a trouble is detected, the System causes the TROUBLE LED on the MKB to flash, the System s internal audible to sound, and the display on the MKB to display the event in the following format: 40 Characters 1 TBL CUSTOM MESSAGE 2 TBL CUSTOM MESSAGE 4 5 6 7 8 9 TBL CUSTOM MESSAGE 10 ALR=000, SUP=000, TBL=002, SEC=000 11 SIEMENS BUILDG TECHNOLOGIES 12 12:22:22 Dec 1, 02 1 1-001 FP-11 14 002 ASD Testing Enabled 15 11:59:59 Dec 1, 02 (002 / 002) Example shown is Canadian Display Figure 7 TROUBLE Event Screen With More Info Key Pressed In addition, the System responds to troubles with programmed output functions. In Figure 7, 1-001 represents the address of the device reporting the trouble. 002 on Line 14 in the More Info area (Lines 1-15) tells you that this is the second (and the most recent) of two troubles received. The status information shown in Line 10 reports the total of alarms, supervisories, troubles, and security conditions. 14

If your System includes a printer, it prints a message from two to four lines long similar to the following: In the above printed message, TROUBLE indicates that the type of occurrence is a trouble; 1-1 is the device address; and #2 is the number of troubles in the list of troubles; [custom message] is a custom message entered using the CSG-M Custom Software Generator (See the CSG-M Programming Manual, P/N 15-09081); [trouble type] is the type of trouble which reported; [device type] is the type of device in trouble. Viewing the List of Troubles To see the trouble list when there are more than eight troubles, press the DOWN key on the MKB. (If your system is set for Canada, the system displays the oldest event first.) How to Individually Acknowledge a Trouble (NFPA 72 Proprietary, UL 1076) The first, unacknowledged, trouble will be placed in line nine. Press TRBL ACK. The System acknowledges the trouble displayed and then places the second, unackowledged trouble in line nine (the fixed line). If your System has the printer option, it prints an acknowledgment message similar to the following: Note that the acknowledgment message includes the term ACK to indicate this trouble was acknowledged. Continue acknowledging troubles as explained above until the System displays the following message: ALL TROUBLES ACKNOWLEDGED The TROUBLE LED glows steadily to indicate that all troubles are acknowledged. If there are no security conditions still in the System, the internal audible goes silent; if any of those conditions still exist, the internal audible pulses. If your System includes a printer, it prints the following message: How to Block Acknowledge a Trouble (NFPA 72 Local, 72 Municipal Tie, 72 Remote Station) Note the specific location of the trouble(s) by using the procedures described above. Unlock and open the door. Press TRBL ACK to acknowledge all troubles. The System displays the following message: ALL TROUBLES ACKNOWLEDGED 15

If your System includes a printer, it prints the following message: If you press TRBL ACK again, the System displays: ALL TROUBLES ACKNOWLEDGED The TROUBLE LED glows steadily to indicate that all troubles are acknowledged. If there are no security conditions in the System, the internal audible goes silent; if any security conditions still exist, the internal audible pulses. Security Security Annunciation When a security condition is detected, the System causes the SECURITY LED on the MKB to flash, the System s internal audible to sound, and the display on the MKB to display the event in the following format: 40 Characters 1 SEC CUSTOM MESSAGE 2 SEC CUSTOM MESSAGE 4 5 6 7 8 9 SEC CUSTOM MESSAGE 10 ALR=000, SUP=000, TBL=000, SEC=002 11 SIEMENS BUILDG TECHNOLOGIES 12 12:22:22 Dec 1, 02 1 1-001 14 002 15 11:59:59 Dec 1, 02 (002 / 002) Example shown is Canadian Display Figure 8 SECURITY Event Screen With More Info Key Pressed 16

In addition, the System responds to security conditions with programmed output functions. In Figure 8, 1-001 represents the address of the device reporting the security condition. 002 on Line 14 in the More Info area (Lines 1-15) tells you that this is the second (and the most recent) of two security conditions received. The status information shown in Line 10 reports the total number of alarms, supervisories, troubles, and security conditions. If your System includes a printer, it prints a message from two to four lines long similar to the following: In the above printed message, SECURITY indicates that the type of occurrence is a security condition; 1-1 is the device address; #2 is the number of the security condition in the list of security conditions; [custom message] is a custom message entered using the CSG-M Custom Software Generator (See the CSG-M Programming Manual, P/N 15-09081); [device type] is the type of device which reported the security condition. Viewing Security Conditions To see the security condition list when there are more than eight security conditions, press the DOWN key on the MKB. If your system is set for Canada, it displays the oldest event first. How to Individually Acknowledge a Security Condition (UL 1076) The first, unacknowledged, security condition will be placed on line nine of the display. Press SEC ACK. The System acknowledges the trouble displayed and then places the second, unackowledged security condition in line nine (the fixed line). If your System has the printer option, it prints an acknowledgment message similar to the following: Note that the acknowledgment message includes the term ACK to indicate this security condition was acknowledged. Continue acknowledging security conditions as explained above until the System displays the following message: ALL SECURITY CONDITIONS ACKNOWLEDGED The SECURITY LED glows steadily to indicate that all security conditions are acknowledged, and the internal audible goes silent. If your System includes a printer, it prints the following message: 17

Ground Fault Indicator When a Ground Fault is detected on the system, a flashing GF icon will appear in the last line of the screen, indicating that the condition exists. When the condition is corrected, the flashing icon will then disappear. 40 Characters 1 TBL CUSTOM MESSAGE 2 4 5 6 7 8 9 10 ALR=000, SUP=000, TBL=001, SEC=000 11 SIEMENS BUILDG TECHNOLOGIES 12 12:22:22 Dec 1, 02 1 14 25 001 Ground Fault Plus Ground Fault Indicator 15 11:59:59 Dec 1, 02 GF (001 / 001) Example shown is Canadian Display Figure 9 System Showing GF (Ground Fault) on Last Line of Display With More Info Key Pressed 18

Reset Procedures Hard Reset Other terms for Hard Reset are Power-up, Initialization, and Cold Reset. Applying power to the System performs a Hard Reset. Doing so initializes the whole system. What Is Lost: Alarms, supervisories, troubles, security conditions (provided they have returned to the normal state). Any user entries such as time and date (MMB-1 only). Arm/disarm. Manual sensitivity adjustment. Time-based control until time is reset (MMB-1 only). What Is Not Lost: CSG-M program. Soft Reset Do a Soft Reset by pressing RESET on the MKB. Soft reset does not work until you acknowledge all alarms, supervisories, troubles, and security conditions and silence the System. What Is Lost: Alarms, supervisories, troubles, security conditions (provided they have returned to the normal state). Arm/disarm (unless option disabled by CSG-M). What Is Not Lost: Any user entries such as time and date. Arm/disarm (when enabled by the CSG-M). CSG-M program. Manual sensitivity adjustment. Time-based control. If you press RESET before acknowledging all conditions and silencing the audible alarms, the display shows a message similar to one of the following: ALARMS NOT ALL ACKNOWLEDGED YET (or) SUPERVISORY NOT ALL ACKNOWLEDGED YET (or) TROUBLES NOT ALL ACKNOWLEDGED YET (or) SECURITY NOT ALL ACKNOWLEDGED YET (or) AUDIBLES NOT ALL SILENCED YET 19

If your System has a printer, it prints a message similar to the following and adds SYSTEM NOT RESET on the bottom line: When the System performs a Soft Reset, the display shows the following message: SYSTEM RESET The System then returns to Normal mode and the display shows the following: 11:59:59 DEC 1, 20xx SYSTEM [custom System message] NORMAL If your System has a printer, it prints the following message: If the System is already in Normal mode when you press RESET, it displays SYSTEM ALREADY NORMAL and does not reset. Please refer to Chapter MXL/MXLV Control Panel Operation, Installation, and Maintanence Manual, P/N 15-09206, for Voice Operation. Please refer to Chapter MXL/MXLV Control Panel Operation, Installation, and Maintanence Manual, P/N 15-09206, for Using the Menu. When reading "Using the Menu" in the above referenced manual, substitute DOWN for NEXT and UP for HOLD. The HOLD feature is not needed to freeze the screen when using the Multi-Line Display., Inc. 8 Fernwood Road Florham Park, New Jersey 0792, Ltd. 2 Kenview Boulevard Brampton, Ontario L6T 5E4 CN