zu verkaufen: 54 Stück Honeywell Drucksensoren 143PC03D neu, und in Originalverpackung Preis: Euro per Stück

Similar documents
Interactive Catalog Replaces Catalog Pages

Interactive Catalog Replaces Catalog Pages

Pressure Sensors: Measurement Type: Gage, Vacuum Gage; Signal Conditioning: Unamplified; Pressure Range: ± 15.0 psi; Port Style: Straight

Gage Unamplified Noncompensated Flow-Through

MS4525DO SPECIFICATIONS FEATURES APPLICATIONS

SSC Series Standard Accuracy Plastic Silicon Pressure Sensors ±2 % Total Error Band, Digital Output, SMT and DIP, 1 psi to 150 psi

Product Training Module: Honeywell TruStability Board Mount Pressure Sensors: Uncompensated/Unamplified NSC Series

MS4525 SPECIFICATIONS

Basic Board Mount Pressure Sensors: NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi]

Miniature Low Pressure Sensors. 24PC Series, Uncompensated/Unamplified 0.5 psi to 250 psi. Datasheet

DP86 Constant Voltage with Fitting

Basic Board Mount Pressure Sensors. NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi] Datasheet

Standard SPECIFICATIONS FEATURES APPLICATIONS

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

Installation Instructions for the MicroPressure Board Mount Pressure Sensors MPR Series Compact, High Accuracy, Compensated/Amplified

MSP100 Pressure Transducer

Miniature Low Pressure Flow-Through Sensors. 26PC Series, Compensated/Unamplified 1 psi to 100 psi. Datasheet

MS1471 SPECIFICATIONS. PC Board Mountable Pressure Sensor 0-60 mv Output Gage and Absolute Low Cost

Basic Board Mount Pressure Sensors: NBP Series Uncompensated/Unamplified 1 Bar to 10 Bar [15 psi to 150 psi]

85 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

Selecting Honeywell Board Mount Pressure Sensors

19 mm Series. Pressure Sensors Low-Cost, Stainless Steel, Isolated Sensors WARNING WARNING. Sensing and Control

FSS-SMT Series. Low Profile Force Sensor

19 mm Series Low Cost, Stainless Steel, Isolated Pressure Sensors

Honeywell Zephyr Analog Airflow Sensors: HAF Series High Accuracy ±50 SCCM to ±750 SCCM

86BSD Digital Output

82 Constant Voltage SPECIFICATIONS. 316L SS Pressure Sensor 19mm Diameter Package 0-100mV Output Absolute and Gage Temperature Compensated

WARNING MISUSE OF DOCUMENTATION

Issue C. Installation Instructions for the Basic Amplified Board Mount Pressure Sensors, ABP Series

154BC SPECIFICATIONS. Please refer to the 154N uncompensated and constant voltage datasheets for more information on different features of the 154.

Board Mount Pressure Sensors Line Guide

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

SX Series Silicon Pressure Sensors 0 psi to 1 psi to 0 psi to 150 psi

TruStability Board Mount Pressure Sensors

MSP100 Pressure Transducer

154BC SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES

Installation Instructions for the Honeywell Force Sensors FSA Series Compensated/Amplified

86BSD Digital Output

Airflow Sensors Line Guide

Airflow Sensors Line Guide

85 Uncompensated SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage

Honeywell Zephyr TM Analog Airflow Sensors. HAF Series High Accuracy ±50 SCCM to ±750 SCCM. Datasheet

PRODUCT TRAINING MODULE: Honeywell Zephyr Airflow Sensors HAF Series High Accuracy

86BSD Digital Output

Honeywell Zephyr Digital Airflow Sensors: HAF Series High Accuracy ±50 SCCM to ±750 SCCM

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

Interactive Catalog Replaces Catalog Pages

Model Super TJE. Ultra Precision Pressure Transducer DESCRIPTION FEATURES

MSP300 Pressure Transducer

U5300 Industrial Pressure Transducer

Force Sensors Line Guide

MSP340 Pressure Transducer

Sub psi SPECIFICATIONS

86A SPECIFICATIONS. 316L SS Pressure Sensor Small Profile V High Level Output Gage, Absolute ASIC Calibrated

D5100 Industrial Differential Pressure Transducer

M5800 Pressure Transducer with Rotatable Display

Installation Instructions for the

D5100 Industrial Differential Pressure Transducer

M5200 Industrial Pressure Transducer

SPECIFICATIONS. SENSOR SOLUTIONS ///LM Page 1 09/2015

Medical Applications SENSING AND CONTROL. Part Innovation. Part Engineering. Total Solutions.

M5800 Pressure Transducer with Rotatable Display

U5700 Submersible Liquid Level Pressure Transducer

U86B. Urea Dosing SPECIFICATIONS FEATURES APPLICATIONS

MEAS Subermsible Liquid Level Pressure Transducer SPECIFICATIONS. Features. Applications

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control. Features:

Heavy Duty Pressure Transducers

2017 Company Overview

Heavy Duty Pressure Transducers Line Guide

M7100 Pressure Transducer

Model A-5. Low Range Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES

FC22 Compression Load Cell

SUBMERSIBLE Flush Diaphragm Liquid Level Sensor AST4520

89BSD Digital Output

316L SS Pressure Sensor High Pressure 0-100mV Output Absolute

Product Training Module: Basic Board Mount Pressure Sensors Uncompensated/Unamplified NBP Series

HIH-5030/5031 Series Low Voltage Humidity Sensors

316L SS Pressure Sensor High Pressure 0-100mV Output Absolute

Model 424. Wing Union/Hammer Union Pressure Sensors DESCRIPTION POTENTIAL APPLICATIONS FEATURES

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4400

U5600. Wireless Pressure Transducer SPECIFICATIONS

MEMS Pressure Sensor Solutions

Interfaces with many electrical components without buffering Thermally balanced integrated circuit for stable operation over a full temperature range

Pressure Transducers Ultrahigh-Purity

Honeywell Zephyr Digital Airflow Sensors: HAF Series High Accuracy 20 SLPM or 200 SLPM

LOW PRESSURE Intrinsically Safe Transducer AST44LP

Application Note Honeywell Zephyr Analog and Digital Airflow Sensors: HAF Series-High Accuracy, ±50 SCCM to ±750 SCCM

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

HIH-4030/31 Series Humidity Sensors

Linear Current Sensors

Configurable Pressure Transducer Model FP Issue 1. Sensing and Internet of Things. Datasheet FEATURES DESCRIPTION DIFFERENTIATION

Potential Applications

Analog Room Pressure Monitor RPC Series

FC23 Compression Load Cell

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4401

Modus Model DA General Eastern Low Differential Pressure Alarm Controller

DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.

MODEL APT 3700N. Smart Pressure Transmitter For Nuclear Service. Duon System Co., Ltd. for Differential / Gauge / Absolute Pressure Measurement

HIH-4000 Series Humidity Sensors

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Oil & Gas. Features:

Transcription:

Megamed AG Elektro-medizinische Apparate Hinterbergstrasse 11 CH-6330 Cham Tel. 041 741 51 51 Fax 041 741 51 44 www.megamed.ch info@megamed.ch zu verkaufen: 54 Stück Honeywell Drucksensoren 143PC03D neu, und in Originalverpackung Preis: Euro 44.00 per Stück Technische Daten: siehe Datenblätter Originalfotos Kontaktperson: Andreas Gürtler Megamed AG Hinterbergstrasse 11 CH-6330 Cham Tel. +41 41 741 51 51 Fax +41 41 741 51 44 E-Mail info@megamed.ch Internet: http://www.megamed.ch Keyword, Keywords Honeywell, MICRO SWITCH, Sensing and Control, 143PC03D, 143 PC 03 D, 143 PC 03D, Transducer, Sensor, 9503257,

143PC03D Sensors: Measurement Type: Bidirectional Gage, Differential; Signal Conditioning: ; : ± 2.5 psi; Port Style: Straight Actual product appearance may vary. Features Robust package PCB termination Fully signal conditioned Potential Applications Medical Oxygen and nitrogen gas distribution in hospitals Dental chairs CPAP (Continuous Positive Airway ) equipment Respirators and ventilators Blood glucose monitors Oxygen conservers Oxygen concentrators Nebulizers Kidney dialysis machines Blood cell separators Environmental Water control valves Instrumentation Irrigation equipment Filter monitoring equipment Leak detection systems in underground telecommunications cables Radiometers Industrial Instrumentation Robotics valves Leak detection Air compressors Analytical Instrumentation Gas chromatography Chemical analyzers Description pressure sensors provide an output voltage that is proportional to the pressure applied. They operate in ranges from 0 psi to 1.0 psi to 0 psi to 30.0 psi using a single, positive supply voltage ranging from 7.0 Vdc to 16.0 Vdc.

Product Specifications Measurement Type Signal Conditioning Maximum Supply Voltage Compensated Output Calibration Response Time Termination Port Style Package Style Bidirectional Gage,Differential ± 2.5 psi 20.0 psi 7.0 Vdc min., 8.0 Vdc typ., 16.0 Vdc max. Yes Yes 1 ms max. PCB Straight Honeywell - 100PC Linearity ± 0.75 % span max. (P2 > P1), ± 0.40 % span max. (P2 < P1) Typical Sensitivity Full Scale Span Null Offset Error Shock Vibration Weight Operating Temperature Compensated Temperature Storage Temperature Media Compatibility 1 V/psi 5.0 Vdc typ. 3.50 Vdc typ. ± 0.25 % span typ. Qualification tested to 150 g MIL-STD-202 Method 213 (150 g half sine 11 ms) 28 g [.987 oz] -40 C to 85 C [-40 F to 185 F] -18 C to 63 C [0 F to 145 F] -55 C to 125 C [-67 F to 257 F] P2 port: Wetted materials; polyester housing, epoxy adhesive, silicon, borosilicate glass, and silicon-to-glass bond P1 port: Dry gas only. UNSPSC Code 411121 UNSPSC Commodity Availability Series Name 411121 Transducers Global 140PC

Sensors Absolute, Differential, Gage, Vacuum Gage/ FEATURES PCB terminals on opposite side from the ports Fully signal conditioned 140PC SERIES PERFORMANCE CHARACTERISTICS at 8.0 ±0.01 VDC Excitation, 25 C Min. Max. Units Excitation 7.00 8.00 16.0 VDC Supply Current --- 8.00 20.0 ma Current Sourcing Output --- --- 10 ma Null Offset (141/142PC) 0.95 1.00 1.05 V Null Offset (143PC)* 3.45 3.50 3.55 V Null Offset 142PC15A @ 2 psia 1.62 1.67 1.72 V 142PC30A @ 2 psia 1.28 1.33 1.38 V Output at Full 5.90 6.00 6.10 V Span (141/142PC) 4.95 5.00 5.05 V Span (143PC)* --- 5.00 --- V Span 142PC15A (2 to 15 psia) 4.28 4.33 4.48 V 142PC30A (2 to 30 psia) 4.62 4.67 4.72 V Ratiometricity Error 7 to 8 V or 8 to 9 V --- ±0.50 --- 9 to 12 V --- ±2.00 --- Stability over One Year --- ±0.50 --- Response Time --- --- 1.00 msec Common Mode ** --- --- 40 psi Weight --- 28 --- grams Short Circuit Protection Output Ripple Ground Reference Output may be shorted indefinitely to ground None, DC device Supply and output are common *Positive and negative pressure measurement. **Higher common mode pressures possible if sensor is not used over entire operating temperature range. Span is defined as the algebraic difference between end points. Please note: actual output is 1 V to 6 V (at 8.00 ±0.01 VDC). Span is then 5V. ENVIRONMENTAL SPECIFICATIONS Operating Temperature Storage Temperature Compensated Temperature Shock 40 to +85 C ( 40 to +185 F) 55 to +125 C ( 67 to +257 F) 18 to +63 C (0 to +145 F) MIL-STD-202, Method 213 (50 g, half sine, 6 msec) Vibration MIL-STD-202, Method 204 (10 to 2000 Hz at 10 g) Media P2 port Wetted materials; polyester housing, epoxy adhesive, silicon, borosilicate glass, and silicon-toglass bond* P1 port Dry gases only *Liquid media containing some highly ionic solutions could potentially neutralize the chip-to-glass tube bond. Honeywell MICRO SWITCH Sensing and Control 1-800-537-6945 USA 1-815-235-6847 International 1-800-737-3360 Canada 37

Sensors Absolute, Differential, Gage, Vacuum Gage/ 140PC SERIES ORDER GUIDE, VACUUM GAGE TYPE psi Max. Max. Max. Linearity, B.F.S.L. 25 to 45 C 25 to +63 C 25 to 85 C 141PC01G 0-1 --- ±1.50 --- --- 5.000 20 --- ±0.75 ±0.30 141PC05G 0-5 ±0.50 --- ±1.00 ±2.00 1.000 20 --- ±0.75 ±0.25 141PC15G 0-15 ±0.50 --- ±1.00 ±2.00 0.333 45 --- ±0.40 ±0.15 140PC SERIES ORDER GUIDE, GAGE TYPE psi Max. Max. Max. Linearity, B.S.F.L. 25 to 45 C 25 to +63 C 25 to 85 C 142PC01G 0-1 --- ±1.50 --- --- 5.000 20 ±0.75 --- ±0.30 142PC02G 0-2 --- ±1.50 --- --- 2.500 20 ±0.75 --- ±0.30 142PC05G 0-5 ±0.50 --- ±1.00 ±2.00 1.000 20 ±1.50 --- ±0.25 142PC15G 0-15 ±0.50 --- ±1.00 ±2.00 0.333 45 ±0.75 --- ±0.15 142PC30G 0-30 ±0.50 --- ±1.00 ±2.00 0.167 60 ±0.75 --- ±0.15 143PC03G ±2.5 --- --- ±1.00 ±1.50 1.000 20 ±0.75 --- ±0.25 143PC05G ±5 --- --- ±1.00 ±1.50 0.500 30 ±0.75 --- ±0.15 143PC15G ±15 --- --- ±1.00 ±1.50 0.177 50 ±0.75 --- ±0.15 140PC SERIES ORDER GUIDE, DIFFERENTIAL TYPE psi Max. Max. Max. Linearity, B.F.S.L. 25 to 45 C 25 to +63 C 25 to 85 C 142PC01D 0-1 --- ±1.50 --- --- 5.000 20 ±0.75 ±0.40 ±0.30 142PC02D 0-2 --- ±1.50 --- --- 2.500 20 ±0.75 ±0.40 ±0.30 142PC05D 0-5 ±0.50 --- ±1.00 ±2.00 1.000 20 ±1.50 ±0.75 ±0.25 142PC15D 0-15 ±0.50 --- ±1.00 ±2.00 0.333 45 ±0.75 ±0.40 ±0.15 142PC30D 0-30 ±0.50 --- ±1.00 ±2.00 0.167 60 ±0.75 ±0.40 ±0.15 143PC03D ±2.5 --- --- ±1.00 ±1.50 1.000 20 ±0.75 ±0.40 ±0.25 143PC05D ±5 --- --- ±1.00 ±1.50 0.500 30 ±0.75 ±0.40 ±0.15 143PC15D ±15 --- --- ±1.00 ±1.50 0.177 50 ±0.75 ±0.40 ±0.15 140PC SERIES ORDER GUIDE, ABSOLUTE TYPE* psia Max. Max. Max. Linearity, B.F.S.L. 25 to 45 C 25 to +63 C 25 to 85 C 142PC15A 0-15 ±0.50 --- ±1.00 ±2.00 0.333 45 --- ±0.40 ±0.15 142PC30A 0-30 ±0.50 --- ±1.00 ±2.00 0.167 60 --- ±0.40 ±0.15 *Tested at 2 psia reference **% Span specification applies to each shift independently. (Null, sensitivity, or combined). 38 Honeywell MICRO SWITCH Sensing and Control 1-800-537-6945 USA 1-815-235-6847 International 1-800-737-3360 Canada

Sensors Absolute, Differential, Gage, Vacuum Gage/ ELECTRICAL CONNECTION Voltage Excitation NULL AND SENSITIVITY TEMPERATURE SHIFT pressure sensors are 100% tested to insure that the maximum null and sensitivity temperature shift does not exceed the specification. The diagram below illustrates how null and sensitivity shift relates to temperature. Note that the maximum shift occurs at temperature extremes. Therefore, if a sensor is not exposed to the entire temperature range, the maximum null and sensitivity shift will actually be less than the value specified. This diagram indicates the temperature shift pertaining to a few listings. Maximum null and sensitivity shift varies from listing to listing. NOTES 1. Terminals are labeled on the sensor. 2. Input and output share a common ground. 3. R L must be greater than or equal to 3000 ohms. INTERNAL CIRCUITRY RATIOMETRICITY SCALING OF 140PC SERIES SENSORS WITH 8V EXCITATION Ratiometricity refers to the output voltage being directly proportional to the supply voltage. 140PC sensors in this catalog are calibrated at 8 VDC supply voltage to provide a 1-6 volt (5V Span) output swing. For example, if supply increases by 50% to 12 VDC, the output voltage increases by 50% to 1.5-9 volts (7.5 V Span). NOTE The output is not perfectly ratiometric. See specifications for the degree of error. 142PC15A Absolute VO 1 V at 0 psia & 6 V at 15 psia 142PC30A Absolute VO 1 V at 0 psia & 6 V at 30 psia 142PC15G Gage VO 1 V at 0 psig & 6 V at 15 psig 141PC15G Vacuum Gage VO 1 V at 0 psig & 6 V at 15 psig 143PC05D Differential VO 1 V at 5 psig & 6 V at 5 psig 143PC15D Differential VO 1 V at 15 psig & 6 V at 15 psig NOTE: 141PC sensors are scaled for vacuum pressure on P2. 142PC sensors are scaled for greater pressure on the P2 side of the chip. Input pressures on absolute units are applied to the P1 port. Other scalings available upon request. Honeywell MICRO SWITCH Sensing and Control 1-800-537-6945 USA 1-815-235-6847 International 1-800-737-3360 Canada 39

Sensors Absolute, Differential, Gage, Vacuum Gage/ MOUNTING DIMENSIONS (For reference only) Dimensions shown apply to Differential and Absolute versions. Gage units are identical, except the P1 port is absent. 140PC CONSTRUCTION 40 Honeywell MICRO SWITCH Sensing and Control 1-800-537-6945 USA 1-815-235-6847 International 1-800-737-3360 Canada