RT FLOW RATE TOTALISER

Similar documents
INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

4) Intrinsic Safety Certification

OPTIBAR P 1010/2010 C Supplementary instructions

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Inductive slot sensor

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

DB5 Intrinsically Safe Sounder Type DB-5

Technical Data. Dimensions

Annubar Flowmeter Series

PEPPERL+FUCHS GmbH

SET Installation and Operating Instructions. Level switch for one sensor

IECEx Certificate of Conformity

E2S Datasheet v10a. The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control.

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. Dimensions

D SYSTEM CONTROL DWG. APPROVED BY. OrCAD 6 ROSEMOUNT 2410

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C

ATEX Installation Instructions for Micro Motion F-Series Sensors with Certificate DMT 01 ATEX E 158 X

BA334D Intrinsically safe Externally powered pulse input field mounting rate totaliser Issue 13

IECEx Certificate of Conformity

BA338C Intrinsically safe Externally powered pulse input panel mounting rate totaliser issue 13

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Data Sheet 220 LEVEL MONITOR. Supplied by. .com. Call us on +44 (0)

Intrinsically Safe Solutions

KHA6-GT*-Ex1. Thermocouple trip amplifiers. Composition. Hazardous area. Safe area. Function. 230 V AC 1-channel. Input EEx ia IIC

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids

Technical Data. General specifications. Rated operating distance s n 5 mm

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

Tank Gauging System Special Safety Instruction

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Connection. e. g. Pt100. reference limit. yellow Output I. Composition

E2S Datasheet v10a

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. Dimensions

MANUAL Oil Level Sensor

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

OilSET-1000 (12 VDC)

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

Safety instructions VEGAPULS 64

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

Hazardous Area Zirconia Oxygen Systems

Technical Data. Dimensions

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

INSTRUCTION MANUAL. Frequency-Pulse Converter, Repeater and Trip Amplifiers Din-Rail Model D1060S D1060S

OMC Ex interface unit. Manual. Version 1.2 August Author: Observator Instruments

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids

VERSAFLOW VORTEX Supplementary instructions

Operating Instructions

Rosemount 3490 Series

INSTRUCTION MANUAL (ATEX)

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS

Installationsmanual GWSL1100/2100, GWML3100

Ex Safety and Installation Instructions GS030 Slew sensor Transmitter & GS031 Slew Sensor Encoder

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Designed & priced for overall appeal

Installation Guide. EXGP Oxygen Analyzer System (ATEX) Interface Electronics Unit

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

SET-2000 Hi Level/Oil

Universal Tank Alarm Type Installation, Operation & Maintenance

Certificate of Compliance

EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU

Installation Guide SmartRadar FlexLine

Software Version 2.01 LEVEL MONITOR MODEL 220

Survey of electrical equipment installed in hazardous areas on tankers

User Guide IM/AK1/23 Rev. N. AK102 and AK103 Gas analyzer systems for Hydrogen-cooled alternators

IS (Intrinsic safety) - Ex (Epsilon x) ATEX CENELEC

Instruction Manual. Model 6553 Series (ATEX) Gas Analyser Systems for Intrinsically Safe Hydrogen & Purge Gas Purity Measurement

IRceL CH4 Methane (CH 4

SET-2000 Oil/Sludge 12 VDC

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

YTA Series Temperature Transmitters [Style: S3] EN :2006, -11:2007, -26:2007. Supply circuit: Ui=30 V, Ii=165 ma,

Supplementary Installation and Operating Instructions. Category II2G

Battery Powered Separator Alarm Type Standalone Unit. Installation, Operation & Maintenance

IECEx Certificate of Conformity

Local Control Panels for VG9000H LCP9H Series. Installation, Maintenance and Operating Instructions

Easidew PRO I.S. Process Dewpoint Transmitter User s Manual

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

TX6831 Data Sheet. Features. Benefits

YO3 - YO4 / YL4 - YO5 / YL5

MAINS KLARGESTER SEPARATOR ALARM INSTALLATION & OPERATIONS MANUAL

L+T GASETECHNIK. Klöpper-Waldmann GmbH & Co. K G. Alarm unit LSG4

Ex Long & Short stroke LPI POSITION TRANSMITTER MKII For linear position measurement in compressors

14300 MAINS SEPARATOR ALARM MANUAL

MANUAL Overflow sensor NVF-104/34-PF

Intrinsically Safe Flame Detector Installation Guide

Electrical Installations Design, Selection, Erection and Inspection

VQ500 Series Combustible Gas Detector Elements

Operating Instructions

OPTIBAR DP 7060 Supplementary Instructions

Fisher LCP100 Local Control Panel

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

PROTECT SRB 200EXi-1A

Local Control Panels for VG9000H LCP9H Series. Installation, Maintenance and Operating Instructions

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC

Transcription:

Universal Mount Series RT FLOW RATE TOTALISER I N S T R U C T I O N M A N U A L S U P P L E M E N T for I N T R I N S I C A L L Y S A F E F L O W R A T E T O T A L I S E R ATEX & IECEx approvals The name of the manufacturer : Address : The type identification (as appropriate) : Rate Totaliser Trimec Industries Pty, Ltd. Caringbah, NSW 9 Australia Model RT***** Other marking required by Directive 94/9/EC The certification code : Ambient temperature range : The ATEX certificate number : The IECEx certificate number : 058 II G EEx ia IIB T4 (-0 C T a +60 C) (-0 C T a +60 C) Sira 06ATEX0X TSA 05.005X

Supplementary Instructions for Intrinsically Safe (I.S.) flow rate totaliser Index. General. Conforming Standards. Overview 4. Mechanical Installation 5. Electrical Installation 5. Inputs 5. Outputs 5. Associated Apparatus 5.4 Wiring 5.5 DIP switch and Jumpers 6. Programming 7. Service 8. Repair. General These instructions must be read in addition to the instrument Instruction Manual if you have purchased an ATEX / IECEx I.S. certified instrument and intend installing it in a hazardous environment for which it is approved. The I.S. certified instrument may be stand alone or fitted to a flowmeter.. Conforming Standards The I.S. instrument is certified in accordance with the IECEx scheme and the ATEX directive. Prior to installation, review the certification marking on the instrument label to confirm it is appropriately certified for your region, suits the site classification and complies with your hazardous area philosophy. IECEx scheme Conforms to Standards IEC 60079-0 (000) and IEC 60079- (999) These standards are identical to AS/NZS 60079-0 (000) and AS/NZS 60079- (000) ATEX Directive Complies with ATEX directive 94/9/EC Conforms to Standards EN5004:997 + Amendments & and EN 5000:00 The instrument has also been assessed against the Essential Health and Safety requirements (ESHR s) as defined in European Directive 94/9/EC for εx II G. The instrument is certified for ia (intrinsically safe) protection suitable for gas group IIA, IIB and temperature class T to T4 in an ambient temperature of -0 to +60 deg C and is suitable for installation in Group II, Zone and areas. The instrument has also been tested to IEC6059 and complies with a protection rating of IP66/67.

. Overview The certified instrument is an I.S. indicator providing a display of flowrate, accumulated total and resettable total. It can be battery powered and/or dc powered via an approved associated apparatus such as an I.S. isolator. In addition, when externally powered the certified instrument provides the choice of one output from the list below; Loop Powered 4~0mA output proportional to flow rate. Low flow rate alarm. High flow rate alarm. High or Low flow rate alarm. Scaled pulse output for remote totalisation. Flowmeter pulse amplifier. 4. Mechanical Installation (also refer Instruction manual) There are additional installation requirements to the Instruction Manual for certified instrument in accordance with the ESHR s as defined in annex II of the ATEX directive 94/9/EC. The ambient temperature must be within the limits -0 to +60 deg C. The instrument must be installed to prevent mechanical and thermal stresses and to prevent an attack from existing or foreseeable aggressive substances. The instrument case is not considered to be an electrostatic risk, however the equipment must not be installed in a position where it may be subjected to an excessive air flow or subjected to rubbing that may cause an electrostatic build up. In all installations appropriate local rules, regulations and directives governing instrument selection, installation practices and requirements must be followed.

5. Electrical Installation 5. Inputs The I.S. instrument can accept pulse or frequency inputs from a variety of flowmeters. When the I.S. instrument is supplied as part of a flowmeter the appropriate input is normally pre-wired at the factory. The common input types are listed below. 5.. Un-powered inputs Reed switch inputs are defined as simple apparatus under the IECEx scheme and the ATEX directive. A reed switch input can be wired directly into the instrument without further certification. DIP switch (debounce) & Switch (pull up) are on Reed switch ( 00hz max.) 4 O N O N Flow Input B Flow Input A High flow alarm Low flow alarm 4 +4~0mA output -4~0mA output 5-0V (ground) not used 0 Ground screen at -0V (5) 6 +8~4Vdc in not used 9 7 Pulse output -0V (ground) 8 Connect across terminals & 5 when using the flow input B. If it is a preference to dc power the instrument refer to Outputs Section of this supplement. 5.. Self Exciting Inputs Non amplified Pick off coils from turbine meters are examples of this type of input. Pick-off coils must be I.S. certified and the entity parameters of the coil must not be less than the entity parameters of the instrument being: Vi of the sensor must be greater than or equal to 8 Vdc Ii of the sensor must be greater than or equal to 00mA Pi of the sensor must be greater than or equal to 0.7W Certified I.S. coil All DIP switches off (position switch ON if unit is effected by line noise) use twisted pairs 4 5 O N O N Flow Input B Flow Input A -0V (ground) High flow alarm 4 Low flow alarm +4~0mA output -4~0mA output not used 0 6 +8~4Vdc in not used 9 7 Pulse output -0V (ground) 8 Connect across terminals & when using the flow input B. If it is a preference to dc power the instrument refer to Outputs Section of this supplement.

5.. Inputs requiring power from the instrument Examples of this type of sensor are open collector output from a Hall Sensor, pre-amplified coils from turbine meters or Namur inductive proximities. Examples are where the voltage required to power the sensor originates from the associated apparatus via the instrument. These sensors must be certified and the entity parameters of the sensor must not be less than the entity parameters of the instrument being: Vi of the sensor must be greater than or equal to 8 Vdc Ii of the sensor must be greater than or equal to 00mA Pi of the sensor must be greater than or equal to 0.7W The power to the instrument must come from a certified source (commonly known as associated apparatus). The entity parameters of the associated apparatus must not exceed those of the instrument being: Voc of the associated apparatus must be less than or equal to 8Vdc Isc of the associated apparatus must be less than or equal to 00mA Pout of the associated apparatus must be less than or equal to 0.7W The associated apparatus may also be used to retransmit an output from the instrument to the safe area. ( refer to Output Section in this supplement for wiring examples ) 5..4 Other Inputs The instrument can also accept isolated pulse/frequency outputs from a powered device such as an open collector or voltage free contact from a mass or electromagnetic flowmeter. These devices must be appropriately certified and the pulse/frequency output must be isolated and have certified entity parameters not less than the entity parameters of the RT instrument being: Vdc Vi of the flowmeter pulse/frequency output must be greater than or equal to 8 Ii of the flowmeter pulse/frequency output must be greater than or equal to 00mA Pi of the flowmeter pulse/frequency output must be greater than or equal to 0.7W DIP SW (pull up) is on O N Flow Input B High flow alarm Low flow alarm 4 Certified pulse or frequency output from host flowmeter 4 5 O N Flow Input A -0V (ground) +4~0mA output -4~0mA output not used 0 6 +8~4Vdc in not used 9 7 Pulse output -0V (ground) 8 Connect across terminals & 5 when using the flow input B. If it is a preference to dc power the instrument refer to Outputs Section of this supplement.

5. Outputs The instrument is certified to provide one of the following outputs. To obtain an output external power is required to be sourced from a certified associated apparatus located in the safe area. In all cases the entity parameters of the associated apparatus must not exceed those of the instrument being: Voc of the associated apparatus must be less than or equal to 8Vdc Isc of the associated apparatus must be less than or equal to 00mA Pout of the associated apparatus must be less than or equal to 0.7W 5.. Two wire 4-0mA loop powered output This configuration is used when the flow input does not require power from the instrument. Terminal designations in parenthesis ( ) refer to the B flow input. Simple apparatus or certified pulse outputs () 5 (5) Hazardous area - 4+ 0~5Vdc supply () 4 () () 5 (5) + - + - 4/0mA 4~0mA output - + MTL 554 Safe area 5.. Three wire 4-0mA Output This configuration is used when the flow input requires power from the instrument. Terminal designations in parenthesis ( ) refer to the B flow input. Pulse output from certified Hall sensor or pre-amplified coil. Hazardous area - 4+ 0~5Vdc supply Vdc Sig. () + - 4/0mA + - - + 4~0mA output -0V 0 MTL 554 Safe area

5.. Pulse (Pre-amplified or Scaled Pulse) or Flow alarm Output when the flow input does not require power from the instrument (refer manual for input DIP switch settings) Instrument jumpers 7B, and 4 must be set to PNP. Terminal 7 is pre-amplified pulse (frequency) if jumper 7A is set to REP Terminal 7 is scaled pulse output if jumper 7A is set to SPO Terminal is low flow alarm output. Terminal 4 is high flow alarm output. Terminal designations in parenthesis ( ) refer to the B flow input. Simple apparatus or certified pulse outputs () 5 (5) () 4 () Hazardous area 6 7, or 4 Sig. - 4+ 5 0~5Vdc supply 4+ - Pulse / switch + () 5 (5) 5 - MTL 55 Safe area 5..4 Pulse (Pre-amplified or Scaled Pulse) or Flow alarm Output when the flow input requires power from the instrument (refer manual for input DIP switch settings) Instrument jumpers 7B, and 4 must be set to PNP. Terminal 7 is pre-amplified pulse (frequency) if jumper 7A is set to REP Terminal 7 is scaled pulse output if jumper 7A is set to SPO Terminal is low flow alarm output. Terminal 4 is high flow alarm output. Terminal designations in parenthesis ( ) refer to the B flow input. Pulse output from certified Hall sensor or pre-amplified coil. Vdc Sig. -0V Hazardous area 6 (6) () 7, or 4 5 (5) Sig. 0~5Vdc supply - 4+ 4+ - Pulse / switch 5 + - MTL 55 Safe area

5. Associated Apparatus The wiring examples illustrated in this supplement are based on MTL 5500 series I.S. Isolators. Alternative isolators with suitable entity parameters are permitted to be used with the instrument. Refer to manufacturers catalogues for full specifications. 5.4 Wiring In addition to the wiring requirements of the Instruction Manual, appropriate local rules, regulations and directives governing wiring practices for I.S. installations must be followed. These include but are not limited to cable lengths, segregation, routing and identification of I.S. cabling. With regards to cable selection and allowable length the associated apparatus capacitance and inductance parameters must not be exceeded by the sum of the capacitances and the sum of the inductances within the loop. When calculating allowable cable length use the capacitance and inductance values of the instrument of 0.5 microf and 0mH respectively. By way of example when using a 55 MTL isolator and assuming cable parameters of 00pF/m & µh/m the maximum allowable transmission distance is calculated to be 550m (800ft). If a 554 MTL isolator is used the allowable transmission distance increases to 50m (6600ft) assuming the same cable parameters. Certain regions such as Europe allow the inductance/resistance ratio of the cable to be used instead of the sum of the inductances. In this case the cable inductance/resistance ratio must be lower than the maximum inductance/resistance ratio permitted by the associated apparatus. 5.5 DIP switch and Jumpers Refer to the Instruction Manual for location, full description & settings of DIP switches & Jumpers. 6. Programming Refer to the Instruction Manual for programming of your instrument. 7. Service The only serviceable item within the instrument is the battery pack and can be replaced insitu. Only the certified I.S. battery assembly P/No. 408 can be used and is available from the locations listed at the end of the Instruction Manual. 8. Repair The instrument must only be repaired by trained personnel using approved spares. Instruments requiring repair must therefore be returned to to the place where you purchased your instrument from or to the instrument manufacturer.

Notes:

Notes:

IM-RT-IS-SUP-4