Environmental Monitoring SmartSlot Card

Similar documents
Environmental Monitoring Card

NetworkAIR RM Air Distribution Unit

Model NT20e Installation Guide

Duct Mount. Installation Instructions

Installation, Operation & Service Manual

Panel Mounted Heat Exchangers by Dantherm, Inc.

Proliphix Thermostat Installation Guide. Release 2.0

PIR Sensor. User s Guide

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

OPERATING MANUAL. The Guardian Hand Held Security Metal Detector

2-Port alarmcharge Hub - Manual

XC Portable Air Conditioning

Installation & Operation Manual

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

Module de relais Relay Module. Manuel de l utilisateur 301RW. User Manual ERP /07

1228s Multidrop INSTRUCTIONS. Installation and Operation of the AMC-1228s Electrochemical Sensor Module For Use With Multidrop AMC Monitors

AIM TECHNICAL MANUAL PATENT PENDING STOP REMEMBER TO ACTIVATE UNIT BEFORE TESTING. See page 9 for Activation Instructions

SC-6 Six Supervised Control Module

MaxLite LED MICRO-T PANEL

AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL

Installation Manual. Detector Bases: PAD100-IB, PAD100-RB & PAD100-SB

CO2 Sensor User and Installation Guide

Model OP155 Air Dryer

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

Owner s Manual. PIR-1 IR Learner

RAM3 Remote Alarm Module

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

Falcon-II Next Generation, Air Quality Monitor CO2 & Temperature

RATIO:GUARD Model E-1S EC Monitor

Dolphin 9900 Mobile Computer

Honeywell Garrett Drop-in Intercooler for 2.3L Mustang EcoBoost IMPORTANT INFORMATION - PLEASE READ CAREFULLY

240 ASSEMBLY & OPERATION MANUAL

Installation Instruction Manual ILS-S

Users Manual. LAURUS Systems, Inc. - Ph: Fax:

CVS Model Inline Multi-Port Ventilators

Heater Installation Kit

AMC-CD2. Human Occupancy Detector INSTRUCTION MANUAL. Please read these instructions completely and carefully before starting.

Radiant Thermostat 519

6502B RF Distribution

Isolated Thermocouple Module

Noran Tel. FUSE PANEL Technical Practice N NCY 2/2 KLM and 4/4 GMT NEBS Level 3 Certified

FW-RA-LED Remote Multiplex Annunciator Panels

Preamplifier Power Supply PPS-02 user's guide

WARNING. Pro Pack Portable Spray Pack 3A1292C. Operation. Model 24F893 Maximum Working Pressure 12 psi (0.83 bar, MPa)

Figure 1. Figure 2. See notes 1 and 2 below.

OWNERS MANUAL MODEL 451 (-101 & -201)

Active Thermal Management. SEC-1 Installation Instructions

FUSE PANEL Technical Practice N N/L9 10/10 GMT NEBS Level 3 Certified

Automatic Phone-Out Home Monitoring Systems

RPI Industries, Inc.

INSTALLER S & OWNER S MANUAL

OPERATION MANUAL Model 8011 & mA

PAD100-6DB & PAD100-4DB PAD100-PD

3500 Installation and Operation Instructions

DBF 4XL Dryer Booster Fans

EXC-450 User s Manual

Incutrol/2 Regulator

AV17 Series Switch-Tek Manual Direct and Remote Drum Mount Float Alarm 17 SEPT 08 Rev A

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

Instruction Leaflet. Read instructions before operating. Retain for future reference.

ELECTRIC FLAT PANEL FIREPLACE HEATER

INSTALLATION AND OPERATING INSTRUCTIONS FOR THE VEHICLE-MOUNTED RADIATION DETECTION SYSTEM

Installation Manual WARNING. Add-on Controller Installation Kit NPE-180A/210A/240A

VX SERIES Wireless Thermostat with Occupancy Sensor

Voice Module Installation Guide. For use with ProSYS 16, ProSYS 40, ProSYS 128

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. H 2015 Pentair Equipment Protection P/N

INSTALLATION INSTRUCTIONS TALKBACK MODULE

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

Surge Protective Devices Installation, Operation and Maintenance Manual. LowProfile Series: 080 and 120

Hazardous Area Ringdown Telephone

0 A EIS Intrinsically-Safe Plug-in Intelligent Photoelectronic Smoke Detector INSTALLATION AND MAINTENANCE INSTRUCTIONS

SERVICE MANUAL (v1) UL / ULC. WET CHEMICAL HAND PORTABLE RESTAURANT KITCHEN FIRE EXTINGUISHERS Model: SF-6LK / WBDL-6LK

Instruction Leaflet. Read instructions before operating. Retain for future reference.

MCD. Corona Discharge Ozone Generators MANUFACTURED BY Bullock Lane San Luis Obispo, CA

OPERATION MANUAL MODEL & ACCELEROMETER

6 Sheet Strip-Cut Shredder for Home/Office

! "! # Please read these installation and operating instructions completely and carefully before starting.

CZ-6A Six Zone Interface Module

Instruction Leaflet. Read instructions before operating. Retain for future reference.

OPEARATING GUIDELINES FOR AERO-252 (Pages 1 to 3 contain general information on CO Guardian. Pages 4 to 6 contain information specific to Aero 252)

Storage Tanks. Instruction Manual. To the Installer: Please attach these instructions next to the water heater.

Miniature Thermoelectric Cooler Controller MTCC-01 user's guide

Introduction... 1 System Overview... 1 System Diagram... 2

Blade Series Heat Exchanger Operation and Installation

Installation Manual NPE-180A/240A WARNING. Add-on Controller Installation Kit

Model 5190-F Temperature/Humidity Probe

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

RPI Industries, Inc.

INSTRUCTIONS PARTS LIST For President, Monark, Standard, and Fast-Flo Pumps, and Agitator

OPERATING MANUAL. The Guardian Hand Held Security Metal Detector

Model 5190-E Temperature/Humidity Probe

SSF1610B-CN TRUSTED FOR OVER 100 YEARS. 16 inch (40cm) Oscillating. Stand Fan. Instruction Leaflet PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS

USE AND CARE GUIDE FOR MODEL MEK1, MEK15. Express Cordless Kettle

Infra-Heat Lumbar Cushion & Extender

READ AND SAVE THESE INSTRUCTIONS DRANE-KOOLER. Water Tempering Device. Installation, Operation, and Maintenance Manual

USER MANUAL. Bottled Water Dispenser SAVE FOR FUTURE USE. Model #

installation instructions Fan Tray System FTA-3/FTA-6

DUAL VOLTAGE REFRIGERATORS 220/240 VOLTS AC AND 12/24 VOLTS DC INSTALLATION AND OWNER S MANUAL

Series TY-B & TY-FRB, 10 mm Orifice, ISO 7/1-R3/8 Upright, Pendent, and Recessed Pendent Sprinklers Standard and Quick Response General Description

FUSE PANEL. Technical Practice N N/L33 10/10 GMT Front Access NEBS Level 3 Certified

Transcription:

Environmental Monitoring SmartSlot Card AP9612TH Installation and Quick Start Manual

Contents Introduction............................. 1 Overview 1 Product inventory 1 Safety notice 2 Your inspection and warranty responsibilities 2 Hardware requirements 2 Data reporting 2 Installation.............................. 3 How to install the card 3 How to connect the card 4 How to test the card 5 Periodic maintenance 5 Sensor Zone Connections.................... 6 Sensor zones and pin location 6 Connection information 7 Multiple sensors in a zone 7 Example hookup 8 Sensor Selection........................... 9 Dry contact sensors 9 Normally open and normally closed sensors 9 Detectors that need power 9 For more information 9 Obtaining Service........................ 10 Specifications............................ 11 Warranty Information..................... 12 Limited warranty 12 Warranty limitations 12 Life-Support Policy........................ 13 General policy 13 Examples of life-support devices 13 i

Introduction Overview The Environmental Monitoring Card is an American Power Conversion (APC) SmartSlot accessory that performs temperature and humidity sensing, as well as contact monitoring. The card supports up to four zones of contact monitoring, and each zone supports both normally open and normally closed contacts. The card will report temperatures from 0 to 60 C (32 to 140 F) and relative humidity from 10 to 90%. Product inventory The Environmental Monitoring Card Temperature and humidity probe (AP9512TH) Screw terminal block for contact monitoring Hook and loop probe fasteners 1

Introduction continued Safety notice The Environmental Monitoring Card is intended solely for use in the supplementary surveillance of equipment. APC does not recommend this product for protection of life or property. APC will not knowingly sell the card for use in such applications. APC disclaims all liability arising out of improper use of the card as described herein. Your inspection and warranty responsibilities Inspect the card immediately, and notify the carrier and the seller if there is any shipping damage. Fill out and return the enclosed warranty card before you begin using the unit. Hardware requirements The card requires an APC device with an available accessory slot. This device can be a UPS equipped with an accessory slot or a SmartSlot Expansion Chassis with a supporting UPS. Data reporting The card also requires some means of reporting its data. The following APC products can report data for the card: Web/SNMP Management Card (AP9606) Out-of-Band Management Card (AP9608) PowerChute plus UPS power management and diagnostic software Ambient temperature and humidity thresholds for the first probe. Contact closure settings for only one sensor for each of the four contact sensor zones. The first sensor is recognized if you mix normally open and normally closed settings for the same zone. PowerNet Adapter Other APC products that support Web or SNMP management. 2

Installation How to install the card First install your UPS, and then install the Environmental Monitoring Card in a slot, as follows: 1. Shut down protected equipment and turn off the UPS. Warning: Failure to turn off the device could result in damage to your Environmental Monitoring Card. 2. Use a #2 Phillips screwdriver to remove the two screws holding the plate that covers the card slot. Save the screws and the plate. Caution: Handle the card by the end plate only. Do not touch the exposed printed circuit board. 3. Slide the card into the slot as shown in the following figure. The panel of the card should be flush with the front of the card slot. Warning: Inserting the card upside down can damage the card. The sides of the printed circuit board must align with the card guides in the sides of the slot. 4. Secure the card with the screws removed in step 2 and proceed to How to connect the card on page 4. 3

Installation continued How to connect the card 1. Connect the supplied probe to probe connector 1 on the card. Place the probe using the supplied hook and loop fasteners, if needed. Note: The probe is designed for use on a flat surface in a protected area with adequate air flow and minimal dust. Do not operate the unit where temperature and humidity are outside the limits specified on page 11. Warning: Do not cover the ventilation holes on the probe. Do not immerse the probe or place it where dew can form. Do not use the probe in an environment with chlorine gas or insecticides. 2. If you want to use contact monitoring, connect contact sensors to the removable screw terminal block. (See Sensor Zone Connections beginning on page 6). The contact monitoring connection is a two-piece design. Strip the wire insulation 0.25" (6 mm). The connector accepts wire sizes from 14 AWG (1.6 mm 2 ) to 26 AWG (0.4 mm 2 ). 3. Connect the screw terminal block to the sensor zones connector of the card. The figure below shows Zones 1 and 2 in use and Zones 3 and 4 open. 4. Turn on the UPS and the protected equipment. 4

Installation continued How to test the card 1. Use your data reporting system to confirm that the card is working. (See page 2.) 2. Check that the probe is connected to probe connector 1. The card should transmit temperature and humidity values to the reporting system. 3. Activate each sensor according to the sensor manufacturer s recommendation. Use the data reporting system to verify that each sensor operates. Periodic maintenance The Environmental Monitoring Card requires the following periodic maintenance: Confirm contact sensing using the sensor manufacturer s recommended intervals and methods. Use the data reporting system to verify that each sensor operates. Clean the probe whenever there is a visible buildup of dust. Gently brush or vacuum off the dust. Do not blow any type of compressed gas into the probe. 5

Sensor Zone Connections Sensor zones and pin location Pin Function 1 power supply, +12 VDC nominal, 60mA max 2 power supply ground and normally open connection for all zones 3 zone 1 common 4 zone 1 normally closed 5 zone 2 common 6 zone 2 normally closed 7 zone 3 common 8 zone 3 normally closed 9 zone 4 common 10 zone 4 normally closed 6

Sensor Zone Connections continued Connection information The Environmental Monitoring Card supports normally open and normally closed loop systems, and allows mixing of normally open and normally closed sensors on any zone. See the figures below for more information on using multiple sensors in one zone and for system hookup. Note: Do not cross-connect the card s sensors with sensors from any other system. Multiple sensors in a zone To avoid receiving alarm indications on unused zones, install a jumper wire between the COM and NC connectors for each unused zone. To use more than one sensor on a zone, follow the diagram below. Connect normally open sensors in parallel and normally closed sensors in series. 7

Sensor Zone Connections continued Example hookup See the figure below for a typical hookup. Note that in this example system Zone 1 is a normally closed motion zone with power for the passive infrared detector supplied by the card. Zone 2 is a normally open zone, Zone 3 is a combination of a normally open and normally closed zone, and Zone 4 is not used. 8

Sensor Selection Dry contact sensors The Environmental Monitoring Card may be used with any dry contact closure type sensors. The card s sensor inputs are designed to monitor circuits that have no voltage potential of their own. Connecting the card s sensor inputs to any circuit other than a dry closure type will void the warranty and may result in damage to the card. Normally open and normally closed sensors In general, any normally open (NO) or normally closed (NC) dry contact sensor may be used with the card. Such sensors include: magnetic contact switches window foil hamper switches heat detectors water sensors pressure sensors Detectors that need power Additionally, the card provides a source of power for those detectors that need power. These include: passive infrared (body heat) detectors smoke sensors photo relay detectors The card provides 12 VDC at up to 60 ma at pins 1 and 2 of the sensor zones connector for sensors that require power. For more information For a list of supported sensors, go to the APC Web site at http://www.apc.com/support. Follow the link to Knowledge Base and enter sensors in the search box at the bottom of the page. You may also call APC Customer Support at a number on the back cover for more information. 9

Obtaining Service If problems persist 1. Note the serial number and date of purchase of the card. Contact Customer Support at a phone number or address on the back cover of this manual. 2. Be prepared to provide a description of the problem. A technician will help solve the problem over the phone, if possible, or will give you a return material authorization (RMA) number. 3. If the card is under warranty, repairs or replacement are free of charge. If the warranty has expired, there will be a charge for repair or replacement. 4. Pack the card carefully to avoid damage in transit. Damage sustained in transit is not covered under the warranty. Enclose a letter in the package with your name, address, RMA number, a copy of the sales receipt, daytime phone number, and check (if applicable.) 5. Mark the RMA number clearly on the outside of the shipping carton. The factory will not accept any materials without this marking. 6. Return the card by insured, prepaid carrier to the address provided by the Customer Support technician. 10

Specifications Product specifications Item Specification Electrical Operating voltage Operating current draw Temperature Accuracy Humidity Accuracy 16 27 VDC 30 madc (exclusive of any attached sensors) ±2 C (±3.6 F) from 0 to 40 C (32 to 104 F) ±8% RH, 10 to 90% RH at 25 C (77 F) ±8% RH, 30 to 80% RH from 15 to 30 C (from 59 to 95 F) Physical Size (h w d) Weight 10.2 10.2 3.8 cm (4 4 1.5 in) 140 g (0.3 lb) Shipping weight: 320 g (0.7 lb) Environmental Elevation: Operating: Storage: Temperature: Operating: Storage: Probe operating temperature 0 to 3000 m (0 to 10,000 ft) 0 to 15 000 m (0 to 50,000 ft) 0 to 40 C (32 to 104 F) 25 to 65 C ( 13 to 149 F) 0 to 60 C (32 to 140 F) Approvals EMC verification Electromagnetic immunity FCC Class A, DOC Class A, EN55022 Class A EN55024 verified 11

Warranty Information Limited warranty American Power Conversion (APC) warrants the Environmental Monitoring SmartSlot Card to be free from defects in materials and workmanship for a period of two years from the date of purchase. Its obligation under this warranty is limited to repairing or replacing, at its own sole option, any such defective products. This warranty does not apply to equipment that has been damaged by accident, negligence, or misapplication or has been altered or modified in any way. This warranty applies only to the original purchaser. Warranty limitations Except as provided herein, American Power Conversion makes no warranties, express or implied, including warranties of merchantability and fitness for a particular purpose. Some jurisdictions do not permit limitation or exclusion of implied warranties; therefore, the aforesaid limitation(s) or exclusion(s) may not apply to the purchaser. Except as provided above, in no event will APC be liable for direct, indirect, special, incidental, or consequential damages arising out of the use of this product, even if advised of the possibility of such damage. Specifically, APC is not liable for any costs, such as lost profits or revenue, loss of equipment, loss of use of equipment, loss of software, loss of data, costs of substitutes, claims by third parties, or otherwise. This warranty gives you specific legal rights and you may also have other rights, which vary according to jurisdiction. 12

Life-Support Policy General policy As a general policy, American Power Conversion (APC) does not recommend the use of any of its products in the following situations: life-support applications where failure or malfunction of the APC product can be reasonably expected to cause failure of the life-support device or to significantly affect its safety or effectiveness. direct patient care. APC will not knowingly sell its products for use in such applications unless it receives in writing assurances satisfactory to APC that (a) the risks of injury or damage have been minimized, (b) the customer assumes all such risks, and (c) the liability of American Power Conversion is adequately protected under the circumstances. Examples of life-support devices The term life-support device includes but is not limited to neonatal oxygen analyzers, nerve stimulators (whether used for anesthesia, pain relief, or other purposes), autotransfusion devices, blood pumps, defibrillators, arrhythmia detectors and alarms, pacemakers, hemodialysis systems, peritoneal dialysis systems, neonatal ventilator incubators, ventilators (for adults or infants), anesthesia ventilators, infusion pumps, and any other devices designated as critical by the U.S. FDA. Hospital-grade wiring devices and leakage current protection may be ordered as options on many APC UPS systems. APC does not claim that units with this modifications are certified or listed as hospital-grade by APC or any other organization. Therefore these units do not meet the requirements for use in direct patient care. 13

. APC Worldwide Customer Support Customer support for this or any other APC product is available at no charge in any of the following ways: Visit the APC Web site to find answers to frequently asked questions (FAQs), to access documents in the APC knowledge base, and to submit customer support requests. http://www.apc.com (Corporate Headquarters) Connect by links to APC Web pages for specific countries and regions, each of which provides customer support information. http://www.apc.com/support/ Submit customer support requests. Contact an APC Customer Support center by telephone or e-mail. Regional centers: APC Headquarters (U.S. and Canada) (1) (800) 800-4272 (toll free) Latin America Europe, Middle East, Africa Japan (1) (401) 789-5735 (United States) apctchla@apc.com (353) (91) 702020 (Ireland) apceurtech@apc.com (03) 5434-2021 jsupport@apc.com Local, country-specific centers: go to http://www.apc.com/support/ contact for contact information. Contact the APC representative or other distributor from whom you purchased your APC product for information on how to obtain local customer support. Entire contents copyright 2001 American Power Conversion. All rights reserved. Reproduction in whole or in part without permission is prohibited. APC, the APC logo, NetShelter, SmartSlot, PowerNet and PowerChute are trademarks or registered trademarks of American Power Conversion Corporation. All other trademarks, product names, and corporate names are the property of their respective owners and are used for informational purposes only. 990-0129A 03/2001