ELEGANCE IPX4 IPX7. Low Carbon Fan with EC Motor Installation and Operating Instructions. 6 models:

Similar documents
ELIX 1003 IPX4. Energy Efficient Centrifugal Fan with EC Motor Installation and Operating Instructions

"Microbox" DC Models MBOX 125/2DC MBOX 125/2DC204

"Microbox" Continuous Mechanical Extract Ventilation Units. Installation, Operating and Maintenance Instructions

WHHR Midi & Midi Lite

"WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use

isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans

G Installation manual Solitude - dmev unit

SPECIFICATION casing manufactured from aludip steel in white low energy DC external motor aluminium plate heat exchanger

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans

Lo-Carbon SELV Tempra

Residential Carbon Friendly Ventilation SAP Q Eligible. ventilation

Centrif Duo & Centrif Duo Plus

Lo-Carbon Quadra Centrifugal Fan

Lo-Carbon Quadra SELV

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Installation manual Mori HR

WHHR125DC - Aera. Whole House Mechanical Ventilation with Heat Recovery - MVHR

Simply Silent Contour 4 (100mm) Axial Extraction Fan

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref.

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

Xpelair Simply Silent TM Contour Fan

Xpelair Simply Silent DX150

ISCG90SS _03 ISCG90SS

Lo-Carbon Quadra Centrifugal Fan

Xpelair Simply Silent TM DX100 Fan

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

ART cm Island Curved Glass

User and maintenance manual

Xpelair Simply Silent DX100B

Installation & Operating Instructions

LV100 Standard LV100PC Pull Cord LV100T Timer LV100H Humidistat LV100HP Humidistat and Pull Cord LV100PIR

100cm Chimney Hood GB IE

Xpelair Simply Silent DX100

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

CG60/ 70/ 80/ 90/ 100 SS/BK

GB User and maintenance manual

irconcentre.co.uk airooncentre.co.uk

Internal/External Wall/Window Fan Range GX6. Installation and maintenance instructions Retain for future use

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

Silhouette Installation and Wiring Instructions

Lo-Carbon SOLO Plus SELV Centrifugal Bathroom/Toilet Fan

9 inch and 12 inch Axial Fans Models MV230P, MV230AR and MV300AR Instructions for installation, maintenance and safe use.

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

MODEL: DV72 R & L. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual

Box60/ 70/ 90. Box60_70_90 v8

AXIAL FAN User s manual. Quiet-dMEV 100 DC.

HOTLINE:

EXTRACTOR HOOD. Please read all the instructions carefully before starting the installation. 230 / 240V 50Hz

IF IN DOUBT, INSTALLATION SHOULD BE MADE BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH CURRENT WIRING REGULATIONS.

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

Purge Ventilation Unit. Product Manual. ventilation systems TP625

Triton Systems Anti-Condensation Products Data Pack

Instructions for use

Titon CME1 Q Plus Mechanical Extract Ventilation Unit

SP16. 08/50740/1 (UK) - Issue 1

Trimbox Mixed Flow Fans. Product Manual. ventilation systems TP220T TP221T TP222T TP223T

USER MANUAL. ICON60H Version 00. Vertical Glass Hood

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Verdi 90 & 120 Ceiling Hood Re-Circulating and Ducted Installation & User Instructions

Cooker Hood LA-72-CAN.

IMPORTANT SAFETY INSTRUCTIONS DANGER: WARNING:

INSTALLATION AND USER S MANUAL COOKER HOOD RS-600/A-S

Titon HRV1 Q Plus HRV1.5 Q Plus HRV2 Q Plus Heat Recovery Ventilation Units

Thank you for choosing EnviroVent

CI/SfB (57.7) 3rd Edition WINNER2011. Winners of the Energy Efficiency Initiative 2011 Award with our Lo-Carbon Continuous Ventilation Product Range.

Installation & Operating Instructions

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2

General safety precautions English

November This product has been reconfigured Please read these instructions

Leonardo 90 Wall Hood

EZT90BL Extractor. Installation, Use and Maintenance.

Hamlet 60 & 80 Wall Hood

OSC... INSTRUCTION MANUAL - KITCHEN EXTRACTOR HOOD

Turbo Inline Fan, White - Non Illuminated Art no.33500

AXIAL FANS USER S MANUAL

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions.

Decentralised Mechanical Extract Ventilation 2 Speed Axial Extract Fan with Humidity Enabler Installation Guide

Models: RP-10, RP-15, RP-20. User Manual

User s Information Manual

Installation and Wiring Instructions

IN 900 BIC UK INSTRUCTION MANUAL - KITCHEN EXTRACTOR HOOD

Apartment Ventilation. "Microbox" Continuous Mechanical Extract Units

Lo-Carbon T-series Window & Roof Models

General safety precautions English

IMPORTANT- RETAIN FOR FUTURE REFERENCE CALL:

General safety precautions English

Rigoletto 60,90 & 120 Built-In Cupboard Hood

Nabucco Island Hood. Installation & User Instructions. Please read these instructions carefully before installing and operating this appliance

A B C D E F 2

installation and operating instructions K224 rangehood

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

Air always contains a certain amount of water in the form of vapour. This determines the

ENGLISH INSTALLATION AND USER S MANUAL FRENCH NOTICE D INSTALLATION ET D UTILISATION ITALIAN MANUALE D ISTRUZIONE

CAN60 / CAN60SV _01 CAN60_CAN60SV. WARNING: Read the instructions before using the appliance.

PROZONE INSTALLATION AND OPERATING INSTRUCTIONS FOR UK-PR ISS-B

Cooker Hood CHIM60 CHIM70 CHIM90 CHIM101 CHIM110. Installation & User s instructions

EDD61 & EDD91 Extractors

Range Hoods. General Manual. For Models: IVN900X, IVN900N, IVCC900X, IVCG900, IVSG900

EVG Extractors. Manual for Installation, Use and Maintenance

Transcription:

ELEGANCE Low Carbon Fan with EC Motor Installation and Operating Instructions 6 models: - SAP Appendix Q Eligible 3 speed continuous running - timer - humidity control - SELV - low voltage for all domestic wet rooms for walls, ceilings or windows IPX4 IPX7

"Elegance - HIGH PERFORMANCE, LOW CARBON FANS INSTALLATION and OPERATING INSTRUCTIONS THIS LEAFLET MUST BE AVAILABLE TO THE USER The product you have purchased is an extractor fan for exhausting directly outside or through medium lengths of ducting and is suitable for wall, ceiling or window (with optional kit) installation. To ensure optimum operation and guarantee a long life, please read this manual carefully. It explains how to install correctly, use and maintain the product properly. Following these instructions will ensure the reliability of the product and extend its working life. The manufacturer will not be held responsible and will not accept any responsibility for damage caused to persons or things due to improper use with reference to the precautions outlined in this leaflet. The product, constructed using state of the art technology, complies with current standards regarding electrical equipment. It conforms with the EMC 2004/108/EC European Directive regarding radio interference suppression and electro-magnetic compatibility. WARNING: Serious injury or death could result if these instructions are not carefully followed Do not use this product for any purpose other than that for which it was designed. Remove the product from its packaging and make sure that it has not been damaged. If in doubt, contact the supplier, authorised dealer, service centre or manufacturer to check that the product will still operate correctly. Do not attempt to use or repair the product before doing this. Do not leave packing material within the reach of children or unskilled people. To dispose of the pack aging and the appliance at the end of its useful life refer to the recycling rules in force. The use of any electrical product requires compli ance with some basic rules which are listed below: - do not touch it with wet or damp parts of the body (e.g hands, feet). - this product is not intended for use by persons (including children) with reduced physical, senso ry or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the product by a person responsible for their safety. The fan should be sited where it is inac cessible to such people. - children should be supervised to ensure they do not play with the product. The product should be connected to the mains electricity supply or electrical outlet only if: - the electrical voltage and frequency correspond to those shown on the rating label. - the capacity of the electricity supply is sufficient to operate the product at its maximum power. - suitable electrical protection is provided for the product to be installed. The electrical supply to which the fan is connected must comply with all existing regulations. All installations must comply with current IEE wiring regula tions. Before maintenance or cleaning is carried out, the product must be switched off and disconnected from the mains electricity supply. If a fault, malfunction or anomaly of any type occurs, the fan should be isolated (switching it off and disconnecting it from the mains electricity supply) and advice sought from qualified personnel. Always request original spare parts for repairs If the product needs to be removed, turn off the mains supply circuit-breaker and then disconnect the fan. The fan MUST BE installed as detailed in this leaflet 2

WARNING: Damage could be caused to the product if the installation instructions are not followed The product should not be used in an ambient temperature higher than 40 C (104 F). The product should not be exposed to atmospheric agents (rain, sun, snow, etc.). The product or its parts should not be placed in water or other liquids. Routine maintenance as described below should be carried out to check the condition of the fan. The air or fumes being extracted must be clean and free from greasy particles, soot, chemical and corrosive agents, flammable or explosive mixtures. The product must be installed by professionally qualified personnel. Incorrect installation can cause damage to people, animals or property, for which the manufacturer cannot be held liable. The product must be connected to the electricity supply via a double pole switch of a suitable size, with contact openings of at least 3 mm. If the electrical supply board (or switching device) is located some distance from the fan a means of local isolation must be provided. To ensure optimum operation, do not block the air intake and exit vents. Any ducting used must be free of blockages, and should be insulated if in an unheated area. The room where the product is operating must have adequate air replacement to ensure max mum effectiveness. If the product is sited in a room containing a fuel burning appliance which is not of the balanced flue type, the installer must ensure that air replacement is adequate both for the fan and the fuel burning appliance (UNI CIG 7129). The product must not be used as an activator for water heaters, stoves, etc. The product must not exhaust into ducts designed to evacuate fumes from combustion in stoves or other combustion-powered devices. RANGE Trickle Speed 1-8 lt/sec - 28.8 m³/h Trickle Speed 2-13 lt/sec - 46.8 m³/h EL1003 - this fan combines the latest technology with energy saving and efficiency. It is a quiet running, 3 speed fan. It is designed to run continuously at a pre-selectable choice of 2 trickle speeds (fixed at installation). The user can boost the fan speed to its maximum performance when required by means of the cord or remove the cord and use a remote switch, light switch, PIR sensor or humidistat. The EL1003 is SAP Appendix Q Listed EL1003LV - SELV, 24v version EL1003. EL1003DT - 3 speed, continuous running fan with delay-on timer and pull cord. The delay-on timer version will run at low speed until the boost speed is activated by means of the cord or, if the cord is removed, by means of a remote switch, light switch, PIR sensor or humidistat. There is a 2 minute delay before the fan starts to run at its high speed - if the boost speed is deactivated before that time lapse, the fan will continue to run at low speed. If the boost speed is activated, the fan will operate at high speed until the boost switch is turned off. After this, the fan will continue at high speed for the length of time set on the timer overrun adjustment, between 2 and 30 mins. (See page 8). After the overrun time has elapsed, the fan will return to the slower speed. EL1003DTLV - SELV, 24v version of EL1003DT EL1003HDT - 3 speed, continuous running fan. The fan runs continuously at the pre-selected lower speed, and the boost speed will start to operate automatically when the relative humidity (adjustable between 40% and 90% +/-5% tolerance) reaches the pre-set level and will continue to operate at this speed until the humidity has been dispersed and the 3

adjustable over-run timer (adjustable from 2 to 30 minutes) has completed its cycle. The boost speed can also be activated by as described for model EL1003DT EL1003HDTLV - SELV, 24v version of EL1003HDT 1 INSTALLATION 2 3 4 5 4

6 7 8 9 5 10

INSTALLATION 1. check there is nothing missing in box 2. remove front cover 3. drill hole in wall - allow extra width if using ducting - it is the installer's responsibility to use the appropriate core cutter to obtain the correct hole diameter. 4. use fan assembly as template to mark drill holes 5. drill 4 x 6mm dia holes 6. fit wall plugs 7/8 decide whether to have cable access from rear (recessed) or top (surface) of fan - if from top ensure that included grommet is properly fixed. (See dia 8). If cable is to come through rear of fan, fit rubber ring (included) 9. screw fan to wall 10. connect cable using cable clamp - see dia 10. NB this fan is double insulated and does not need to be earthed 11. replace front cover 11 12. if fan is to be installed in a ceiling, drill out the hole (A) for condensation drainage 56 12

JUMPER SWITCH These fans are designed to run continuously at one of 2 lower speeds fixed at installation using the jumper switch. EL1003, EL1003DT and EL1003HDT: Minimum Speed 1 - Jumper 2 in Minimum Speed 2 - Jumper 2 out (N.B Jumpers 1 and 3 will be pre-set at the factory, depending on the fan model you have) The user can boost the fan speed to its maximum performance by using cord or remote switch. N.B When installing fans via a remote switch, pullcord switch must be left in "off" position and the cord removed. WIRING DIAGRAMS ELs - 3 Speed with Cord ELs - 3 Speed via remote switch SELV with Pull Cord Switch EL1003LV - 3 Speed with Cord EL1003DTLV - 3 Speed with Timer and Cord EL1003HDTLV - 3 Speed with Humidistat, Timer and Cord SELV with External Switch EL1003LV - 3 Speed EL1003DTLV - 3 Speed with Timer EL1003HDTLV - 3 Speed with Humidistat and Timer 7

SELV Products All SELV (safety extra low voltage) products must be installed to conform to IEC 60364. Connection between the fan and the mains supply must be by means of a safety isolating trans former of the appropriate power rating The transformer should be connected to the mains supply via a double pole safety switch with a contact opening of at least 3mm The transformer will operate only one fan The transformer must not be installed in Zones 1 or 2, but should be installed as close as possible to the fan within Zone 3 The cable used to connect the transformer to the fan must have a section area of at least 1.5mm 2 and a maximum length of 10m If the fan is a humidity control model, it must be installed using the transformer supplied for that product. MAINTENANCE Before any maintenance or cleaning operation, switch off the fan and disconnect it from the main power supply. The front cover can be cleaned with a dry cloth or soft brush The fan must not come into contact with any kind of liquid or solvent. If this should occur, contact a qualified technician before reassembling the fan. NOTE: The motor does not require lubrication as it is maintenance free "sealed for life" type. TRIMMER ADJUSTMENT To adjust the humidistat and timer trimmers, remove the front cover of the fan (Fig 2) to access the trimmers. The humidistat (HY) can be adjusted between 40% and 90% relative humidity. Turn clockwise to decrease sensitivity and set at a higher level of relative humidity. The timer (T) is adjustable between 2 and 30 minutes. Turn the trimmer clockwise to increase the overrun time, or anti-clockwise to decrease it. DISMANTLING & RECYCLING This product has been designed and constructed using high-quality materials and components that can be recycled or re-used. Vectaire Ltd, Lincoln Road, Cressex Business Park, High Wycombe, Buckinghamshire, HP12 3RH Tel: +44 (0)1494 522333. Fax: +44 (0)1494 522337. Email: sales@vectaire.co.uk Web: www.vectaire.co.uk Elegance 0712 E & O.E