The Vanguard System TM VM-2900 Air Seeder Monitor. Operator s Manual

Similar documents
Introduction... 1 System Overview... 1 System Diagram... 2

Introduction... 1 System Overview... 1 System Diagram... 2

PM100/PM100E PLANTER MONITOR. Operator s Manual

SA SIREN AMPLIFIER

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Quick Setup Guide for IntelliAg Model NTA607HD

LOUP II DRILL MONITOR OPERATION MANUAL. SOFTWARE v45

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

DCC-2200 / DCC-2300 CLIMATE CONTROL MODULE for Vintage Air Gen II Modules

INSTALLATION AND OPERATING INSTRUCTIONS FOR THE VEHICLE-MOUNTED RADIATION DETECTION SYSTEM

CD6102 / CD6102 OC / CD6102-2

M113S Users Manual. MERLIN STEALTH M113S Electric Fence Energizer GROUP OF COMPANIES. PDF created with pdffactory trial version

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 700

INSTALLATION AND INSTRUCTION MANUAL

1-16 Row Population Monitor

Static Pressure Control

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 715

Remote Vehicle Control System

Thermostat Remote Control & Receiver

ion Genesis Pump Controller

REMOTE MOBILE SECURITY SYSTEM USER MANUAL

52 BERKSHIRE CEILING FAN

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

FW-RA-LED Remote Multiplex Annunciator Panels

52 CEILING FAN. Owner s Manual Models #50336, 50337

Street Thunder ST240 SIREN AMPLIFIER INSTALLATION AND OPERATING INSTRUCTIONS

Installation and Owner Man u al

Natural Himalayan Salt Lamp

Henny Penny Electronic Bun Warmer Model BW-1 Model BW-4 Model BW-4 Model BW-4/3 Model BW-6 Model BW-8

Long Range Radio Alarm Transmitter

INSTALLATION INSTRUCTIONS

52 STRATHMERE CEILING FAN

Mold Alert... Operation Manual P0270

GROUP OF COMPANIES. MERLIN STEALTH Electric Fence Energizer. Users Manual

MIXERS SMX10-1, SMX20-1, SMX20-2, SMX30-1 INSTRUCTION MANUAL

PitBoss User Manual. Version /24/2013 Copyright 2013 PumpAlarm.com, LLC

Expanded Backup Control Installation & Operator s Instruction Manual

IMPORTANT. World-wide Patents. VIGIA is a trademark of Col-Ven S.A.

OPTIONAL SLIT TUBING RECOMMENDED (AVAILABLE AT MOST HARDWARE STORES) Violet Grey. +12v Dash Lighting (See Lighting Mode)

GETZ MANUFACTURING PART # CYLINDER DRYER

MAN AUTO IMPORTANT INSTRUCTIONS PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE

VX SERIES Wireless Thermostat with Occupancy Sensor

CWR265SZ 26 Bottle Built-in Wine Cooler Owner s Manual

M1200 Series Limited Warranty Dependability Promise

NS1100 / NS2200 Installation Guide & Owner s Manual

Fan Speed. Auto Swing. Timer. Power. Mode. Fan. Only. Saver. Temp. Dry. Fan. Speed. Auto Swing. Timer. Power. Mode. Saver. Only. Temp.

48 TAYLOR CEILING FAN

Carson Manufacturing Co., Inc North Rural Street Indianapolis, IN Phone: (888) Fax: (317)

SA VOLT SIREN AMPLIFIER

Installation Manual. Expansion Module 0100 Version 1.0 EXP HBX Control Systems Inc.

flexibility programmed settings.

Universal Fan and Light Remote Control

Long Range Radio Alarm Transmitter

OWNER'S MANUAL T0140. Contents Page #


Non-Programmable Digital Thermostat

Turin LED Ceiling Fan

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

Street Thunder ST280 SIREN AMPLIFIER & LIGHT CONTROLLER INSTALLATION AND OPERATING INSTRUCTIONS

Installation and Operation Instructions 1000 Series Siren & Controller

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

QTC15 Temperature Controller Operation Manual

SYSTEM CONTROL KIT Model: CK-41P

DUST FREE CARBON Whole House Air Purifier

Propane Fume Detection System

5+2 DAY. OWNER S MANUAL Venstar Inc. 05/08

Installation and Operations Manual

Miniature Thermoelectric Cooler Controller MTCC-01 user's guide

Instruction Manual. AcuRite Atlas. Indoor Display model 06061

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

Horizontal Bottle Cooler Installation and Operation Manual

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

PAC-2750 ELECTRIC COOLING FAN CONTROLLER

Model 65 Humidifier Control Owner s Manual

Instruction Manual and Warranty

Questions or Concerns? Please contact us Mon - Fri 9:00AM - 5:00PM PST at (888) or Natural Himalayan Salt Lamp

Table of Contents. Safety Information Main Functions Set-Up Operation Maintenance Troubleshooting Specifications Customer Support Warranty Information

INSTALLATION AND OPERATING INSTRUCTIONS. For Reliance Controls Emergency Power Transfer Switch Kit Model Number 30216BRK

120 VAC SYSTEM CONTROL KIT Model: CK-63

OWNER S MANUAL. Remote Mobile Security System. Models: PL50 PL60

Projection Alarm Clock USER GUIDE

Air Purifier. Purificador de aire. Use and Care Guide Manual de uso y cuidado. Model / Modelo : HAP52010E

36 & 48 E-Z Cone Fan. Installation & Operator s Instruction Manual (Direct Drive)

5+2 DAY. Digital Thermostat. residential. & 1-cool. up to 2-heat PROGRAMMABLE THERMOSTAT. Venstar Inc. 05/08

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

Remote Sensor Module: EB-RSM-01

Henny Penny Blast Chiller/Freezer Models BCC/BCR-140 Models BCC/BCR-175 Models BFR/BCR-350

SEALING FIBER SEALING COMPOUND

Smart IR Sensor. Installation and Operation Manual PNEG Date: PNEG-1640

Instruction Manual for Meat Grinder XMCA-SS

Instruction Manual for Meat Grinder XMCA-SS

Power Pack Service Manual

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

Surge Protective Devices Installation, Operation and Maintenance Manual. LowProfile Series: 080 and 120

Frosty Factory of America, Inc.

IMPORTANT: DO NOT DO NOT DO NOT DO NOT DO NOT DO NOT DO NOT DO NOT DO NOT DO NOT

Model 405 AIRGARD Fume Hood Monitor

APPLICATION MANUAL FOR SCU SERIES COMPRESSOR UNITS AND SWU SERIES WATER COOLED CONDENSING UNITS

Protocol Station Remote Alarm

Remote Vehicle Control System. Security and Convenience System

Transcription:

The Vanguard System TM VM-2900 Air Seeder Monitor Operator s Manual

Introduction... 1 System Overview... 1 System Diagram... 2 Installation... 3 Console Mounting... 3 Monitor And Power Connections... 3 VM-2900 Console Main Harness... 4 Module Mounting... 5 System Configuration... 7 Split Row Enable... 7 Minimum Seeding Rate... 7 English Conversion For Seeding Rate... 9 System Operation... 11 Power Sequence... 11 Sensor Detection... 11 Planting... 13 Single Row Failure... 13 Multiple Row Failure... 14 All Rows Failure... 14 Dimming... 15 Lift Switch... 15 Hopper Level Low... 15 Errors... 16 Troubleshooting Guide... 19 Unit Will Not Power On. No LEDs Will Light During The Power Up Sequence.... 19 Row Or Hopper Indicator Fail To Illuminate After Self-Test... 19 Rows Fail That Are Correctly Planting. Self-Test Indicated The Sensor Was Present... 20 Hoppers Fail That Are Filled Above The Sensor... 20 Hoppers Fail To Alarm When Seed Is Not Blocking Sensor... 21 Unit Powers On, All LEDs Blink On, And No Error Occurs... 21 Unit Displays An E Followed By A Module Number... 21 Unit Displays A C Followed By A Module Number... 22 Unit Displays A C Followed By An A... 22 VM-2900 Service Parts... 23 Monitor And Main Harness... 23 Module And Module Harnesses... 23 Extensions... 23 i

ii

INTRODUCTION SYSTEM OVERVIEW The provides accurate blockage and low cost monitoring of up to 128 rows and 8 hopper levels. It can scan 8 Modules and display the status of 16 rows for each module, or 15 rows and 1 hopper per module. The monitor provides: 128 row maximum monitoring capability 8 ASM II module scanning capability 16 row display capability per ASM II Module or 15 rows and 1 hopper level sensor Implement lift switch input 16 row indicators 7 segment indicator (displays 1,2,3,4,5,6,7,8,9,0, A,C,E,H,L) OFF/ON/DIM-ALARM CANCEL toggle switch 5 step LED dimming for full sunlight/night time use Internal audible alarm (chirp/blare output) 12 Vdc power relay switching output (for modules) Minimum seeding rate adjustment switch/split row enable Figure 1 VANGUARD VM-2900 Air Seeder Front Panel On/Off/ Dim-Alarm Cancel toggle switch Minimumseedingrateadjustment/splitrowenabletoggleswitch INTRODUCTION / 1

SYSTEM DIAGRAM The following provides an illustration of the VANGUARD VM-2900 system. Figure 2 VANGUARD VM-2900 System Diagram TM Console Module 5 Right Input power Relay control Communication lines Lift switch Extension may be required Lift switch P2 Module 4 Power harness Monitor harness P1 Main communication harness Extension harnesses Module 3 Sensors 1 2 Rear View 15 16 Module 2 Extension may be required Module 1 Left Diagram Notes: P1 modules address from left end to middle, while P2 modules address from middle to right end Lift switch is optional Module power is not carried through the console due to worst-case voltage drop on 128-row system P2 is not required for systems with four modules or less (64 rows or less) P1 can drive four modules 2 / INTRODUCTION

INSTALLATION CONSOLE MOUNTING To mount the VM-2900 console, use the mounting bracket as a template for drilling. Mount the console in a location that is easy to view and easy to reach for threshold adjustment, split row activation, dimming, and alarm silencing. Figure 3 Console Mounting Before drilling, assure the power and main hitch harness can be routed in the proper manner. Harness retention and routing outside of the cab is also important. Do not use the enclosure as a guide when drilling. This may cause damage to the mounting bracket. MONITOR AND POWER CONNECTIONS Route the power leads of the main harness to the battery. Allow some slack to tie the harness off to the console bracket for strain relief and protection of the harness. INSTALLATION / 3

Figure 4 Monitor and Power Connections Red Black + - 12 Vdc The monitor operates on 12Vdc only. The red (fused) lead should be connected to the positive battery terminal and the black lead should be connected to the negative battery terminal. VM-2900 CONSOLE MAIN HARNESS Insert the connector of the harness into the J1 connector inside the bottom of the VM-2900 console. 4 / INSTALLATION

Figure 5 Main Harness Connection Route the main harness to the rear of the tractor. Mount the relay (part of the main harness) to a suitable location at the rear of the tractor, assuring the connector will reach the implement connector at the hitch. MODULE MOUNTING Lay out all harnesses and modules on the implement to determine proper mounting locations. Refer to Figure 2 for layout guidelines. Use the module as a template for drilling in a location that will allow the tower harness to reach all the sensors installed on the air seeder and be connected to the hitch cable or next module in line (1/4-20 hardware is recommended). INSTALLATION / 5

Figure 6 Module Mounting Before drilling, assure the harness can be routed in the proper manner. Consider harness placement in regard to air seeder movement during planting. 6 / INSTALLATION

SYSTEM CONFIGURATION SPLIT ROW ENABLE This feature will set the VM-2900 to monitor only odd or even numbered rows. To configure the VM-2900 to monitor only even numbered rows, hold the +/ - switch to + and turn the power switch ON. The letter E as well as the even row indicators will be displayed. Release the +/- switch immediately. Figure 7 Even Row Enable NOTE: Turning the power switch ON with the +/- switch in the center position configures the system to monitor all rows. To configure the VM-2900 to monitor only odd numbered rows, hold the +/- switch to - and turn the power switch ON. The letter O will be displayed as well as the odd row indicators. Release the +/- switch immediately. Figure 8 Odd Row Enable MINIMUM SEEDING RATE The Minimum Seeding Rate feature allows for setting a minimum number of seeds per second that will cause a seed row to fail and alarm to sound. The factory default minimum seeding rate is 2 seeds per second. To set the minimum seeding rate, perform the following: 1. Power up the console and wait until the start up test of modules, seed sensors, and hopper level sensors is complete. 2. Momentarily hold the +/- switch in either the + or - position to change the threshold adjustment setting. 3. Refer to Figure 9 and enter the desired threshold. 4. Holding the +/- switch to the + position will increase the LED s. Holding the +/- switch to the - position will decrease the LED s. SYSTEM CONFIGURATION / 7

Figure 9 Minimum Seeding Rate Table Number of LED's on Seeds vs. Second Threshold LED High Range (H) LED Low Range (L) Indicator (seeds per second) Indicator (seconds per seed) 1 2 seeds every second 7 1 every 10 seconds 2 4 seeds every second 8 1 every 9 seconds 3 8 seeds every second 9 1 every 8 seconds 4 10 seeds every second 10 1 every 7 seconds 5 12 seeds every second 11 1 every 6 seconds 6 16 seeds every second 12 1 every 5 seconds 7 20 seeds every second 13 1 every 4 seconds 8 30 seeds every second 14 1 every 3 seconds 9 40 seeds every second 15 1 every 2 seconds 10 50 seeds every second 16 1 every 1 second 11 60 seeds every second 12 70 seeds every second 13 80 seeds every second 14 100 seeds every second 15 120 seeds every second 16 150 seeds every second Figure 10 Minimum Seeding Rate Example E+ O - Power/dim/alarm cancel switch 2 4 8 10 12 16 20 30 40 50 60 70 80 100 120 150 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Module = H Row Fail Threshold = 8 Seeds per Second 1/10 1/9 1/8 1/7 1/6 1/5 1/4 1/3 1/2 1/1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Module = L Row Fail Threshold = 1 Seed per 2 Seconds 8 / SYSTEM CONFIGURATION

ENGLISH CONVERSION FOR SEEDING RATE sps = 43560 x V * 5280 / 3600 x S / 12 P = population (seeds/acre), V = speed (m.p.h.) S = spacing (inches), sps = threshold (seeds/s) SYSTEM CONFIGURATION / 9

10 / SYSTEM CONFIGURATION

SYSTEM OPERATION POWER SEQUENCE Moving the I-O (power) switch to the center position turns on the monitor. Upon power up, the Air Seeder Monitor provides the operator with an indicator test by illuminating all 16 rows and the 7 display segments. The alarm will output a single chirp during the display test. Figure 11 Power Up Indicator and Alarm Test Chirp SENSOR DETECTION After the indicator test is complete, the monitor will begin displaying the results of the sensor detection. The Module Number will display 1 and the row numbers with detected sensors will illuminate. If another VM-2900 module is connected, the Module Number will advance to 2 and the row numbers with detected sensors will illuminate, and so on for additional modules. The monitor will dwell for 2 seconds on each module. In the event a hopper/row module is connected, the monitor will display the seed sensors detected first, then detect the hopper, with an H displayed. The following sensor detection sequence, Figure 12, depicts 56 rows of monitoring with 12 rows connected to VM-2900 module 1, 16 rows connected to modules 2 and 3, and 12 rows and 1 hopper connected to module 4. SYSTEM OPERATION / 11

Figure 12 Sensor Detection Sequence 1 2 3 4 5 6 7 8 9 10111213141516 Figure 13 illustrates a row that was not detected during the sensor test is not usable. This could indicate that a sensor is not connected or has failed on module 1. Figure 13 Example of Failed Row 1 2 3 4 5 6 7 8 9 10111213141516 Figure 14 illustrates that no rows are lit on the Hopper detection sequence. This indicates that a Hopper module was detected but no Hopper sensors were detected. 12 / SYSTEM OPERATION

Figure 14 Example of Hopper Failure 1 2 3 4 5 6 7 8 9 10111213141516 PLANTING After the sensor detection is displayed to the operator, the monitor is ready for the planting operation. When planting begins, monitoring operation starts. As long as every reported row detects at least the minimum seeding rate, the 7-segment display will scan through each detected module number. Figure 15 Planting Display - No Failed Rows SINGLE ROW FAILURE If a single row failure is detected, the appropriate Module Number will be displayed and the corresponding row output will light and the alarm will sound. Figure 16 provides an example of what the display would show with Module 2, Row 5 failure. SYSTEM OPERATION / 13

Figure 16 Example of Single Row Failure Alarm Unless the alarm is cancelled by toggling the I/O (power) switch, the display will continue to show this condition. If this occurs, the display will scroll through each module as before, but will illuminate only the failed rows. If an additional single row failure occurs, the operation will return to dwell upon that failure. If a second alarm cancel is performed, the display will again scroll through each module as before, but will illuminate both failed rows. MULTIPLE ROW FAILURE If rows fail on more than one module, the monitor will sequence through the Module Numbers and display the corresponding row numbers for 2 seconds on each module. For example, if Module 1, Row 8 and Module 2, Row 5 fail, the following display sequence will occur and loop. Figure 17 Example of Multiple Row Failure Alarm The looping of the modules with failed rows will continue unless the alarm is cancelled. If this occurs, the display will scroll through each module as before, but will illuminate the failed rows. If additional rows fail, the operation will return to looping the new failures only. If a second alarm cancel is performed, the display will again scroll through each module as before, but will illuminate all row failures. ALL ROWS FAILURE If all rows fail, which is common when the planter is lifted and no lift switch is installed, the Module Display will output an A, all rows will light, and the alarm will chirp. 14 / SYSTEM OPERATION

Figure 18 Example of All Rows Failure Chirp DIMMING A dimming feature is included for low light planting conditions. After the sensor detection has been completed and only during non-alarm conditions, the dim switch can be toggled into the up position to dim the indicators. Each dim step will cause the alarm to chirp. Once the lowest dim level has been reached, the alarm will sound for 2 seconds. After 2 seconds, or if the switch is released and toggled up again, the indicators will brighten. Once the highest brightness level has been reached, the alarm will sound for 2 seconds. LIFT SWITCH The lift switch input will keep the ALL ROWS FAILURE from occurring. When the Lift Switch input is grounded, it is considered active (inhibits ALL ROWS FAILURE). When active, the Module Display will output an L and will no longer scan through the modules. The alarm will chirp. Figure 19 Active Lift Switch Chirp HOPPER LEVEL LOW Hoppers can be monitored with the Dj ASM II console in the event a 15 row Hopper Module is connected to the system. If a hopper is low, the sensor will ground the signal line and an H will appear on the display, indicating a hopper is empty. The LED number indicates which module the hopper level sensor is connected. In the following example, the hopper sensor on Module 4 is indicating a low hopper. SYSTEM OPERATION / 15

Figure 20 Example of Low Hopper Level Chirp ERRORS The monitor can detect 8 Vdc error during start-up. If this error occurs, the Module Display will output an E, followed by the module number. In the following example, Module 5 detected an 8 V sensor supply voltage short to ground. Figure 21 Example of Module 5 Start-Up Error Alarm This error CANNOT be disabled using the Alarm Cancel feature. The problem must be either repaired or the module must be disconnected from service. The other error that the monitor will display is a communication error. If this error occurs, the monitor will display a C, followed by the module number. In the following example, the monitor detected a communication error with Module 5. 16 / SYSTEM OPERATION

Figure 22 Example of Module 5 Error Alarm A Module 5 Communication error is similar to the 8 Vdc error. The C and 5 will toggle back and forth. The error cannot be eliminated until the communications failure has been corrected and power has been cycled OFF/ON. Figure 23 Example of Communications Error Alarm The error C/A indicates the monitor is experiencing communication problems with all modules. The letters C and A will toggle back and forth. This occurs, for instance, when the monitor is powered up with no modules connected. SYSTEM OPERATION / 17

18 / SYSTEM OPERATION

TROUBLESHOOTING GUIDE UNIT WILL NOT POWER ON. NO LEDS WILL LIGHT DURING THE POWER UP SEQUENCE. Probable Cause: 1. Loose connection between power harness and monitor 2. Blown fuse 3. Defective monitor or main harness 4. Defective module, harness, or sensor 5. Poor battery connection 6. Insufficient system voltage Corrective Action 1. Assure harness connections are centered and fully inserted. Assure the main harness is properly connected to the monitor. 2. Assure the positive and negative connections are not reversed. Check the fuse in the power harness near the battery. If it is blown, troubleshoot and repair fault. Replace with a 7.5A AGC. Do not replace fuse with one having a higher amperage rating - the console could be damaged internally. 3. Disconnect implement main harness. Measure for short between red (power) and black (ground) wires. If shorted, the power harness or the console is faulty and requires repair or replacement. Contact your Parts and Service Dealer or call DICKEY-john in the U.S.A. at 1-800-637-3302. 4. Disconnect the system at the hitch and measure for short between red (power) and black (ground) wires. If shorted, isolate by disconnecting harnesses until fault is found. Contact your Parts and Service Dealer or DICKEY-john in the U.S.A. at 1-800-637-3302. Outside of the U.S.A., contact your dealer or national distributor or DICKEY-john Europe at 00 33 (0) 1 41 19 21 80. 5. Check battery connections and assure they are clean and tight. 6. Make sure battery voltage is between 11 and 16 Vdc. ROW OR HOPPER INDICATORS FAIL TO ILLUMINATE AFTER SELF-TEST Probable Cause 1. Defective sensor or harness wire that is intermittent 2. Poor harness connection at console or at sensor that is intermittent 3. Defective harness or sensor cable (signal shorted or power open) Corrective Action TROUBLESHOOTING GUIDE / 19

1. Swap the sensor with another row or hopper. If problem moves, sensor is faulty. Otherwise, harness or module is faulty. 2. Check module harness connections at the module and sensors. Check module harness for pinches, worn, or broken elements. Check sensor cables for pinched, worn, or broken elements. 3. Check module harness for pinched, worn, or broken elements. Check sensor for pinched, worn, or broken wires. ROWS FAIL THAT ARE CORRECTLY PLANTING. SELF-TEST INDICATED THE SENSOR WAS PRESENT. Probable Cause 1. Minimum seeding rate set too high 2. Defective seed sensor 3. Poor harness connection at console or at sensor that is intermittent 4. Defective sensor or harness wire that is intermittent 5. Defective harness or sensor cable (signal shorted or power open) 6. Hopper sensor is plugged into seed input Corrective Action 1. Lower the minimum seeding rate (left hand +/- switch). 2. Clean sensing elements using a dry bottle brush. Some seed treatments require scrubbing with water and a commercial cleanser. 3. Check module harness connections at the module and sensors. Check module harness for pinched, worn, or broken elements. Check sensor cables for pinched, worn, or broken elements. 4. Swap the sensor with another row. If the problem moves, the sensor is faulty. Otherwise the harness or module is faulty. 5. Check module harness for pinched, worn, or broken elements. Check sensor for pinched, worn, or broken wires. 6. Assure hopper is only connected to ROW 16/HOPPER connector input. HOPPERS FAIL THAT ARE FILLED ABOVE THE SENSOR. SELF-TEST INDICATED THE SENSOR WAS PRESENT. Probable Cause 1. Defective sensor or harness wire that is intermittent 2. Defective harness or sensor cable (signal shorted to ground) Corrective Action 1. Check module harness connections at the module and sensors. Check module harness for pinched, worn, or broken elements. Check sensor cables for pinched, worn, or broken elements. 2. Swap the sensor connection with another hopper connector or move sensor. If the problem moves, the sensor is faulty. Otherwise, the harness or module is faulty. Check module harness for pinched, worn, or broken elements. Check sensor for pinched, worn, or broken wires. 20 / TROUBLESHOOTING GUIDE

HOPPERS FAIL TO ALARM WHEN SEED IS NOT BLOCKING SENSOR. SELF-TEST INDICATED THE SENSOR WAS PRESENT. Probable Cause 1. Defective hopper sensor 2. Defective sensor or harness wire that is intermittent 3. Defective harness or sensor cable (signal shorted to power) 4. Hopper sensor is connected to seed input Corrective Action 1. Clean sensing elements using a dry bottle brush. Some seed treatments require scrubbing with water and a commercial cleanser. 2. Check module harness connections at the module and sensors. Check module harness for pinched, worn, or broken elements. Check sensor cables for pinched, worn, or broken elements. 3. Swap the sensor connection with another hopper connector or move sensor. If the problem moves, the sensor is faulty. Otherwise the harness or monitor is faulty. Check module harness for pinched, worn, or broken elements. Check sensor for pinched, worn, or broken wires. 4. Assure hopper is connected to ROW 16/HOPPER connector input. UNIT POWERS ON, ALL LEDS BLINK ON, AND NO ERROR OCCURS, BUT NO SENSORS ARE DETECTED ON A MODULE. Probable Cause 1. Module harness is not properly connected 2. Defective (8V power or ground open) harness 3. Defective monitor or module Corrective Action 1. Check module harness connections at the module and sensors. 2. Check module harness for pinched, worn, or broken elements. 3. Contact your Parts and Service Dealer or DICKEY-john in the U.S.A. at 1-800-637-3302. Outside of the U.S.A., contact your dealer or national distributor or DICKEY-john Europe at 00 33 (0) 1 41 19 21 80. UNIT DISPLAYS AN E FOLLOWED BY A MODULE NUMBER Probable Cause 1. 8V short error detected by Module Corrective Action 1. Module voltage supply error. Check module harnesses and sensors for short of 8V supply to ground. 8V supply is generated by each module for its sensors. TROUBLESHOOTING GUIDE / 21

UNIT DISPLAYS A C FOLLOWED BY A MODULE NUMBER Probable Cause 1. Communication error with module Corrective Action 1. Lost communication with module. Check indicated module number first and nearby modules next. Check all communications next by each module for its sensors. UNIT DISPLAYS A C FOLLOWED BY AN A Probable Cause 1. Communication error with all modules Corrective Action 1. No modules were detected at power up. Check harnesses and modules for proper connection. 22 / TROUBLESHOOTING GUIDE

The Vanguard System TM Vanguard VM-2900 SERVICE PARTS MONITOR AND MAIN HARNESS VM-2900 Monitor 46794-2001S1 Main Harness 46794-0580 Mounting Bracket 46794-0080 Fuse, AGC 7.5A 20112-0039 Relay F86606-3252 MODULE AND MODULE HARNESS VM-2900 Module, 16 row 46794-2050S1 VM-2900 Module, 15 row/ 1 hopper 46794-2052S1 12 row tower harness 17-3812AS1 16 row tower harness 17-3816AS 12 row harness, 7.5 rows 17-3812A 12 row harness, 15 rows 17-3412A 12 row harness, 30 rows 17-3212A 16 row harness, 7.5 rows 17-3816 16 row harness, 15 rows 17-3416 16 row harness, 30 rows 17-3216 EXTENSIONS 4 extension harness 17-55-4 6 extension harness 17-55-6 10 extension harness 17-55-10 15 extension harness 17-55-15 20 extension harness 17-55-20 25 extension harness 17-55-25 30 extension harness 17-55-30 40 extension harness 17-55-40 45 extension harness 17-55-45 50 extension harness 17-55-50 VM-2900 SERVICE PARTS / 23

24 / DJ ASM II SERVICE PARTS

The Vanguard TM System Warranty Agri Motive Products warrants to the original purchaser for use that, if any part of the product proves to be defective in material or workmanship within one year from date of original installation, and it is returned to Agri Motive Products within 30 days after such defect is discovered, Agri Motive Products will (at our option) either replace or repair said part. Only those parts provided by Agri Motive Products are covered under warranty. The use of parts from other sources will not be eligible for warranty consideration. Purchaser must obtain authorization prior to beginning replacement or repair of potentially failed parts. All parts removed during warranty repair should be held for a period of 60 days after the warranty claim has been submitted to Agri Motive Products. This warranty does not apply to damage resulting from misuse, neglect, accident or improper installation or maintenance. Said part will not be considered defective if it substantially fulfills the performance specifications. THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WAR- RANTIES OF MERCHANTABILITY, FITNESS FOR PURPOSE AND OF ANY OTHER TYPE, WHETHER EXPRESSED OR IMPLIED. Agri Motive Products neither assumes nor authorizes anyone to assume for it any other obligation or liability in connection with said parts and will not be liable for consequential damages. Purchaser accepts these terms and warranty limitations unless the product is returned within fifteen days for a full refund of purchase price. Agri Motive Products reserves the right to deny or reverse any and all warranty claims for parts, labor, or miscellaneous charges when errors are found or warranty provisions are abused or fraudulent claims are submitted. In no case shall Agri Motive Products be liable for any incidental, special, consequential, or similar damages. Agri Motive Products A Division of The Daugherty Companies, Inc. P.O. Box 306 609 East First Street Warren, IN 46792 Phone: 800-258-2415 or 260-375-2652 Fax: 260-375-3800 E-Mail: service@ag-electronics.com Website: www.ag-electronics.com For DICKEY-john Service Department, Call 1-800-637-3302 in either the U.S.A. or Canada This product may be covered under the following or more patents and other patents pending: Pat number 4,555,624