GRUNDFOS PRODUCT GUIDE MAGNA. UPE Series 2000 circulator pumps

Similar documents
GRUNDFOS DATA BOOKLET MAGNA3. Circulator pumps 60 Hz

GRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with 2 or 3 CM, CMV or CR pumps 50 Hz

GRUNDFOS DATA BOOKLET UPS2. Circulator pumps. 50/60 Hz

MORE DEMAND THAN A PUMP GRUNDFOS MAGNA3

MORE DEMAND. than a pump. grundfos MAGNA3

GRUNDFOS DATA BOOKLET SLC, DLC. Pump controllers

GRUNDFOS DATA BOOKLET MTB. Centrifugal machine tool pumps 50/60 Hz

GRUNDFOS INSTRUCTIONS CMBE. Installation and operating instructions. Drinking Water System Component NSF / ANSI 61 NSF / ANSI 372

TYPE LF/LC/LCV END SUCTION PUMPS

GRUNDFOS DATA BOOKLET. Grundfos COMFORT. Circulator pumps. 50/60 Hz

MAGNA3 More than A pump

MAGNA3 MAGNA3. The full Grundfos product range covers all building application areas:

GRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with two or three CM, CMV or CR pumps. 50 Hz

GRUNDFOS INSTRUCTIONS. Sololift2 C-3. Installation and operating instructions

GRUNDFOS PLUMBING & HVAC PRODUCTS

LiqTec, V GRUNDFOS INSTRUCTIONS

grundfos commercial building Grundfos Plumbing Solutions

GRUNDFOS INSTRUCTIONS MAGNA1. Installation and operating instructions

GRUNDFOS PRODUCT GUIDE. Unilift CC, KP, AP. Submersible wastewater pumps 60 Hz

CR A-F-A-E-HQQE 3x400/ HZ

UP/UPS-B/UPN Hot Water Service Circulators

GRUNDFOS SEWAGE & EFFLUENT PUMP ACCESSORIES

CR10-16 A-FJ-A-E-HQQE 3x400D 50 HZ

CRN A-F-G-E-HQQE 3x400D 50 HZ

CR64-1 A-F-A-E-HQQE 3x400D 50 HZ

CR A-F-A-E-HQQE 3x400D 50 HZ

CR32-4 A-F-A-E-HQQE 3x400D 50 HZ

CR20-07 A-F-A-E-HQQE 3x400/ HZ

TP /4-A-F-A-BQQE 400D 50HZ

CR A-F-A-V-HQQV 3x400D 50 HZ

Comfort Series Instant Hot Water System

CRN90-1 A-F-G-V-HQQV 3x400D 50 HZ

CR5-9 A-FGJ-A-E-HQQE 1x220/240 50HZ

CU 300. Installation and operating instructions GRUNDFOS INSTRUCTIONS

COMPASS HIGH-EFFICIENCY WET-ROTOR CIRCULATORS

CR A-F-A-E-HQQE 3x400/ HZ

Grundfos is pleased to announce the sales release of many exciting new products.

CU 300 GRUNDFOS INSTRUCTIONS. Installation and operating instructions

GRUNDFOS INSTRUCTIONS LCD 108. Installation and operating instructions

Pressure Boosting Solutions

TYPE VL/VLS VERTICAL INLINE PUMPS

EFFICIENCY RELIABILITY

SL EX.4.51D

Wilo Stratos Variable Speed Inline Pumps. Engineering Specification

SL S.S.N.51D

ecocirc XL HIGH EFFICIENCY LARGE WET ROTOR PUMP FOR HEATING, COOLING AND POTABLE WATER SYSTEMS A-162C

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

HIGH EFFICIENCY CIRCULATORS. Represented by Taconova Group AG CATALOGUE 2018 EN. easyuse. greatperformance

Bosch Buderus SSB800/1000/1000TL Stainless Steel Condensing Boiler

PRIUX HOME D. High-efficiency double circulating pumps Heating Air conditioning 50 Hz OPERATING RANGE APPLICATIONS BENEFITS

Bosch Buderus SSB1000TL/TL2/TL3/TL4 Stainless Steel Condensing Boiler

GRUNDFOS INSTRUCTIONS. Dedicated Controls. Service instructions

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

GRUNDFOS PRODUCT GUIDE. Domestic Water Supply Family

GRUNDFOS PRODUCT GUIDE. Domestic Water Supply Family

568X, 587X, 588X Series

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM

IMMERSIBLE PUMPS FOR INDUSTRY

Company name: Created by: Phone:

1 Declaration of conformity

General Specifications

5. CONDENSATE PUMPS/UNITS

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

Unilift KP, AP, SU/SV, SE & EF

QUALITY PRODUCTS, INC. OIL-TO-AIR HEAT EXCHANGERS

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

AnaLASER II Detector. Protection Systems. A UTC Fire & Security Company. High-Sensitivity Smoke Detector (HSSD ) FEATURES DESCRIPTION

Water-cooled chillers with High Speed Centrifugal Compressors

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

APPLICATIONS. For the accelerated circulation of hot water in heating circuits with duty point optimisation

Pumps. Heating Drinking water Solar Geothermy Condensate

grundfos SEG AUTOadapt The perfect grinder pump for wastewater transport be think innovate

Pumps BAFA. Heating Drinking water Solar Geothermy Condensate. gefördert

GRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM

Genie Heated Regulator Installation & Operation Instructions

DualPak Series FILE NO: DATE: Feb. 15, 1999 SUPERSEDES: DATE: Sept. 28, DualPak 6900 Series Booster System

Affordable efficiency!

Taco 00 Series Cartridge Circulators

GRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz

Lowara ecocirc and ecocirc PREMIUM

AFUE 95% Heating Input 50,000 to 200,000 Btuh

Circulation pumps. Wet rotor circulators and accessories. Heating Drinking water Solar Geothermy Condensate

PRELIMINARY EDITION

AS950 REFRIGERATED SAMPLERS

Circulation pumps. Wet rotor circulators and accessories. Heating Potable water Solar Geothermy Condensate

Danfoss Self-limiting Heating Cables SLPG-10/26/33, SLPG-18, SLHW-55/70, SLPH-10

MLC Air Cooled Chillers MLC-FC Free Cooling Chillers MLC-AD Adiabatic Chillers

Lowara ecocirc and ecocirc PREMIUM

Circulation pumps. Wet rotor circulators and accessories Heating Drinking water Solar Geothermy Condensate

MTW Series Modular Oil Free Centrifugal Chillers

ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS

Wilo Top S Wet Rotor Circulation Pumps. Engineering Specification

2CP DATA SHEET. Horizontal Two Stage Centrifugal Pumps 2CP 32/210B 2CP 32/200B 2CP 32/200C

PAPANTONATOS. We supply clean water and remove waste water. P u m p s s e r v ic e & e n g i nee r in g. submersible pumps. s e w a g e p u m p s

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

Transcription:

GRUNDFOS PRODUCT GUIDE UPE Series 2000 circulator pumps

Contents Mission Product data Features and benefits Applications 5 eating systems 5 Pumped liquids 5 Type key 6 Performance range, 6 Product range Product range 7 Pump selection 7 Pump size 7 Operating conditions 7 Communication 7 Control mode 7 Operating conditions General recommendations 8 Liquid temperature 8 Ambient conditions 8 Maximum operating pressure 8 Minimum inlet pressure 8 Electrical data 9 Sound pressure level 9 Functions Functions 10 Control modes (factory setting) 11 AUTOADAPT 11 Additional control and operating modes 11 Proportional-pressure control 11 Constant-pressure control 12 Constant-curve duty 12 Max. or min. curve duty 12 Temperature influence 12 Automatic night-time duty 13 Additional operating modes two pumps in parallel 13 Readings and settings on the pump 13 Communication 1 Digital input 1 Digital output 15 Analog input 16 Bus communication via GENIbus 17 Bus communication via LON 17 Functions of expansion modules 17 Construction Motor and electronic controller 18 Pump connections 18 Paint 18 Material specification 19 Installation Mechanical installation 20 Electrical connection 21 Cables 21 Wiring diagram 21 Additional protection 21 Operating modes: 22 Examples of connections 23 Curve conditions Curve conditions 2 Performance curves/technical data 32-100 F 26 65-60 F 28 0-120 F 30 65-120 F 32 Accessories Packaged fitting sets 3 Expansion modules for 35 GENI module 35 LON module 36 R100 36 Order data, cast iron 37, stainless steel 37 Further product documentation WebCAPS 38 WinCAPS 39 2

Mission It is our mission the basis of our existence to successfully develop, produce and sell high-quality pumps and pumping systems world-wide, contributing to a better quality of life and a healthy environment Bjerringbro, Denmark Fresno, California Olathe, Kansas Monterrey, Mexico Allentown, Pennsylvania Oakville, Ontario The world's leading pump company World's largest manufacturer of circulator pumps World headquarters in Denmark North American headquarters in Kansas City - Manufacturing in Fresno, California 80 companies in 5 countries More than 16 million motors and pumps produced annually worldwide North American companies operating in USA, Canada and Mexico Continuous reinvestment in growth and development enables the company to BE responsible, TINK ahead, and INNOVATE 3

Product data The ranges of circulator pumps are specially designed for heating systems domestic hot-water systems (stainless-steel pump housing). Fig. 1 pump GR838 Features and benefits The variable-speed wet rotor circulator is powerful, reliable, intelligent, and energy efficient. incorporates a permanent-magnet rotor, a revolutionary design pioneered by Grundfos. is easy to install, simple to operate, and a good choice for the replacement market. is the smart choice with an array of useful features and benefits: Integrated variable speed drive proportional-pressure duty constant-pressure duty constant-curve duty max. or min. curve duty parallel connection of two pumps (requires additional expansion module). no external motor protection required Short flange-to-flange length for easier replacements low noise level safe selection low energy consumption (all pumps are high efficiency with permanent magnet (PM) motors. Energy class "A" in European energy labeling schedule) patented AUTOADAPT function ensures further energy savings long life and no maintenance external control and monitoring enabled via optional expansion modules.

Product data Applications eating systems Main loop Mixing loops eating surfaces. The circulator pumps are designed for circulating liquids in heating systems with variable flows where it is desirable to optimize the setting of the pump duty point. The pumps are also suitable for domestic hot-water systems. To ensure correct operation, it is important that the sizing range of the system falls within the duty range of the pump. The is especially suitable for installation in existing systems where the differential pressure of the pump is too high in periods with reduced flow demand. The pump is also suitable for new systems where automatic adjustment of pump head to actual flow demand is required without using expensive bypass valves or the like. Furthermore, the pump is suitable for application in systems with hot-water priority where an external contact can immediately force the pump to operate according to the max. curve. Pumped liquids is suitable for thin, clean, non-aggressive and non-explosive liquids, not containing any solid particles, fibers or mineral oil. If the pump is installed in a heating system, the water should meet the requirements of accepted standards on water quality in heating systems. In domestic hot-water systems, the pump should be used only for water with a degree of hardness lower than 17 grains/gallon (1 d). The pump must not be used for the transfer of flammable liquids such as diesel oil and petrol. If the pump is not used during periods of frost, necessary steps must be taken to prevent frost bursts. Additives with a density and/or kinematic viscosity higher than those/ that of water will reduce the hydraulic performance. Whether a pump is suitable for a particular liquid, depends on a number of factors of which the most important are lime content, p value, temperature and content of solvents, oils, etc. 5

Product data Type key Example 0-120 (F) (N) 280 Nominal diameter of suction and discharge ports (mm) Maximum head [dm] Flange connection N: Single-head pump housing of stainless steel Port-to-port [mm] Performance range, [m] [ft] 50 0 10 9 30 8 7 32-100 0-120 65-120 6 20 5 15 65-60 3 10 8 2 7 6 5 10 15 20 30 0 60 80 100 150 200 Q [US GPM] 3 5 6 7 8 9 10 20 30 0 Q [m³/h] TM0 92 210 Fig. 2 Performance range 6

Product range Product range Pump type Supply voltage Port-to-port length Nominal pipe connection Flange connection [V] [inch] [mm] [inch] [mm] GF15/26 GF 0/3 GF 53 32-100 F 1 x 230 6 ½ 165 1.25 32 0-120 F (N) 1 x 230 8 ½ 216 1.5 0 65-60 F (N) 1 x 230 11 ½ 292 2.5 65 65-120 F (N) 1 x 230 11 ½ 292 2.5 15 Pump selection Pump size Selection of pump size should be based on required maximum flow maximum head loss in the system. Operating conditions The operating conditions should be within published pump limits. When selecting a pump, the following limitations shall be considered: liquid temperature and ambient conditions minimum inlet pressure maximum operating pressure. Communication The requirements for external control or monitoring of the pump should be considered, such as access to: speed control of pump or change of setpoint reading of pump data start/stop, fault indication or forced control to max. or min. curve. Control mode In general, Grundfos recommends: The factory setting which is suitable for most installations Proportional-pressure control in systems with relatively great head losses Constant-pressure control in systems with relatively small head losses. 7

Operating conditions General recommendations Water in heating systems Domestic hot water Water containing glycol Liquid temperature Application General Domestic hot-water systems To avoid condensation in the terminal box and the stator, the liquid temperature must always be higher than the ambient temperature. Ambient conditions Water quality according to local standards Degree of hardness up to 17 grains / gallon (1 d ). Max. 50 % glycol. Viscosity 0.3785 ft 2 /hr (10 mm 2 /s). +35 F to +200 F (+2 to +95 C) +35 to +10 F (+2 to +60 C) Ambient temperature during operation +32 to +95 F (0 to +35 C) Ambient temperature during storage/transport 0 to +10 F ( 0 to +60 C) Relative air humidity Maximum 95 % Maximum operating pressure Pump type Max. operating pressure mpa [psi (bar)] 32-100 F 15 (10) 1.0 0-120 F 175 (12) 1.2 65-60 F 175 (12) 1.2 65-120 F 175 (12) 1.2 Minimum inlet pressure The following relative minimum pressures must be available at the pump inlet during operation: Liquid temperature Pump type 167 F / 75 C 19 F / 90 C Inlet pressure [psi / bar] 32-100 F 1.5 / 0.10 5 / 0.35 0-120 F 2.2 / 0.15 6.5 / 0.5 65-60 F 2.2 / 0.15 6.5 / 0.5 65-120 F 2.2 / 0.15 17.5 / 1.2 Note: Actual inlet pressure + pump pressure against a closed valve must be lower than the maximum permissible system pressure. 8

Operating conditions Electrical data Pump type Single-phase 32-100 Single-phase 0-120, 65-60, 65-120 Enclosure class IP (IEC 85) IP (IEC 85) Insulation class F F External start/stop input Expansion module Sound pressure level External potential-free switch. Screened cable. Maximum contact load: 5 V, 10 ma. Setpoint signals GENI module GENI module Signal output Bus input Supply voltage Internal potential-free changeover contact. Screened cable. Maximum contact load: 250 VAC, 2 A. Minimum contact load: 5 VDC, 1 ma. GENI module LON via GENIbus and G10 modules. 1 x 230 V - 10 % / + 6 %, 50/60 z, PE The pump requires no external motor protection. External potential-free switch. Screened cable. Maximum contact load: 5 V, 10 ma. Internal potential-free changeover contact. Screened cable. Maximum contact load: 250 VAC, 2 A. Minimum contact load: 5 VDC, 1 ma. GENI module LON module 1 x 230 V - 10 % / + 6 %, 50/60 z, PE Pump type Single-phase 32-100 Single-phase 0-120, 65-60, 65-120 Sound pressure level 32 db(a) 38 db(a) 9

Functions Functions Single-phase 32-100 Single-phase 0-120, 65-60, 65-120 Control modes (factory setting) AUTOADAPT Proportional pressure control Constant pressure control Additional control and operating modes Constant curve duty Min. or max. curve duty Automatic night-time duty Additional operating modes of twin-head pumps Alternating operation Standby operation Readings and settings on the pump Operating indication Flow indication Setpoint Control mode Fault indication Communication Wireless remote control, R100 External digital input/output External analog input BUS via GENIbus protocol, RS-85 BUS via LonTalk protocol, FTT 10 Function incorporated. Expansion module required. G10-Lon interface required. Not recommended for air conditioning systems. 10

Functions Control modes (factory setting) The pumps have been factory-set to AUTOADAPT. The setpoint is factory-set to approximately half of the maximum pump head. The factory setting is suitable for most installations. The AUTOADAPT control mode is developed specifically for heating applications. max. AUTOADAPT During operation, the pump automatically reduces the factory-set setpoint and adjusts it to the actual system characteristic. fac. auto_min A1 set1 A 3 A 2 set2 TM03 1071 005 1.5 5 0 0 Fig. 3 AUTOADAPT control Note: Manual setting of the setpoint is not possible. When the control mode AUTOADAPT has been activated, the pump will start at set1, corresponding to 50% of its maximum head, and then adjust its performance to A 1, see fig.. When the pump registers a lower pressure on the max. curve, A 2, the AUTOADAPT function automatically selects a correspondingly lower control curve, set2. If the radiator valves close, the pump adjusts its performance to A 3. A 1 : Original duty point. A 2 : Lower registered pressure on the max. curve. A 3 : New duty point after AUTOADAPT control. set1 : Original setpoint setting. set2 : New setpoint after AUTOADAPT control. fac. : xx-60: 11.5 ft xx-100, 18 ft xx-120: 23 ft auto_min : A fixed value of 5 ft The AUTOADAPT control mode is a form of proportionalpressure control where the control curves have a fixed origin, auto_min. Q TM02 0826 090 Fig. AUTOADAPT Additional control and operating modes Grundfos offers additional control and operating modes to meet specific demands. The functions available depend on the pump type and the expansion module chosen, see overview of functions on page 10. Proportional-pressure control The pump head is changed continuously in accordance with the flow demand in the system. The head against a closed valve is half the setpoint. set set 2 Q Fig. 5 Proportional-pressure control The proportional-pressure control is recommended in systems with relatively great head losses. TM00 88 0995 11

Functions Constant-pressure control The pump head is kept constant, independent of the water requirement. set Fig. 6 Constant-pressure control The constant-pressure control is recommended in systems with relatively small head losses. Constant-curve duty Requires the use of an R100 remote control. The pump can be set to operate according to a constant curve like an uncontrolled pump. If an external controller is installed, the pump is able to change from one constant curve to another, depending on the value of the external signal. Q TM00 89 0995 The max. curve mode can be used in periods in which a maximum flow is required. This operating mode is for instance suitable for hot-water priority. The min. curve mode can be used in periods in which a minimum flow is required. This operating mode is for instance suitable for manual night-time duty. Temperature influence Temperature influence function is available with constant and proportional control mode. To be set with the R100 remote control. When temperature influence function is activated the setpoint for head will be reduced according to the liquid temperature. The temperature influence limits can be set to 120 F (50 C) or 175 F (80 C). The temperature limits are not adjustable. These temperature limits are called Tmax. The setpoint is reduced in relation to the head set (= 100 %) according to the characteristics below. 100% actua l Min. Fig. 7 Constant-curve duty Max. Max. or min. curve duty The pump can be set to operate according to the max. or min. curve, like an uncontrolled pump. TM03 0551 0205 30% 68 120 175 T T actual Fig. 9 Temperature influence In the above example, Tmax. = 175 F (80 C) has been selected. The actual liquid temperature Tactual causes the setpoint for head to be reduced from 100 % to actual. F Q TM03 9363 3907 Max. Min. TM00 557 596 Fig. 8 Max. or min. curves 12

Functions The temperature influence function requires: Proportional- or constant-pressure control mode. The pump must be installed in the supply side pipe. System with supply pipe temperature control. Temperature influence is suitable in: systems with variable flows (e.g. two-pipe heating systems), in which the activation of the temperature influence function will ensure a further reduction of the pump performance in periods with small heating demands and consequently a reduced supply pipe temperature. systems with almost constant flows (e.g. one-pipe heating systems and radiant floor heating systems), in which variable heating demands cannot be registered as changes in the head as is the case with two-pipe heating systems. In such systems, the pump performance can only be adjusted by activating the temperature influence function. Selection of Tmax. In systems with a supply pipe temperature of: up to and including +131 F (55 C), select Tmax. = +120 F (50 C), above +131 F (+55 C), select Tmax. = +175 F (+80 C). Automatic night-time duty When automatic night-time duty has been selected, the pump will change automatically between normal duty and night-time duty. Changeover between normal duty and night-time duty takes place as a result of the supply pipe temperature measured by an integrated temperature sensor. The automatic changeover to night-time duty takes place when the temperature sensor registers a supply pipe temperature drop of more than 18-27 F (10-15 C) within approx. 2 hours. The required temperature drop is a minimum of 18-27 F (10-15 C). Changeover to normal duty takes place without a time lag when the temperature has increased by approx. 18 F (10 C). Additional operating modes two pumps in parallel The following operating modes are available for two pumps in parallel if both pumps are equipped with optional GENI module: Alternating operation Pump operation alternates every 2 hours. If the duty pump stops due to a fault, the other pump starts. Standby operation One pump operates continuously. In order to prevent seizing-up, the standby pump starts at a fixed frequency (every 2 hours) and runs for a short period. If the duty pump stops due to a fault, the standby pump starts. Readings and settings on the pump The control panel on the pump control box/terminal box incorporates the basic functions for readings and settings. Fig. 10 control panel Pos. Description 1 Buttons for setting of head 2 3 Indicator lights for operating and fault indication and symbol for indication of external control Button for selection of control mode: AUTOADAPT, proportional pressure, constant pressure and automatic night-time duty Light symbols for indication of control mode and night-time duty 5 Light fields for indication of head, flow and operating mode TM03 8752 207 13

Functions Communication pump enables communication via wireless remote control, R100 connection to an external alarm device digital input/output analog input. Digital input The function of the digital input is selected with the R100 remote control. External start/stop The pump can be started or stopped via the digital input, see fig. 19, terminals 7 and 8. Expansion module required for 32-100. Start/stop Normal duty Q TM00 98 2802 Q Stop Fig. 11 R100 remote control is designed for wireless communication with the Grundfos R100 remote control. The R100 offers additional possibilities of setting and status displays for the pump. The R100 can be used for the following functions: reading of operating data reading of fault indications setting of control mode setting of 1/3 ft (0.1 m) head increments selection of external setpoint signal allocation of pump number making it possible to distinguish between pumps in connection with parallel operation via bus selection of function for digital input. has various inputs and outputs for external signals for forced-control functions. Some functions may require an expansion module, see Expansion modules for. External forced max. or min curve The pump can be forced to operate on the max. or min curve via the digital input. Use of the digital input for forced max. or min. curve requires installation of the expansion module, GENI module. Max. curve Q Q Min. curve Q Q Normal duty Max. curve Normal duty Min. curve 1

Functions Digital output The pumps incorporate a signal relay with a potential-free changeover contact for external fault indication. 32-100* The function of the signal relay can be changed from "Fault" to "Ready" or "Operating" or "Ready" mode with the R100. These pumps require expansion modules. The functions of the signal relay are as shown in the table below: *Expansion module required for 32-100. Signal relay Fault signal 1 2 3 NC NO C 1 2 3 NC NO C 1 2 3 NC NO C Not activated: The electricity supply has been switched off. The pump has not registered a fault. Activated: The pump has registered a fault. Signal relay Operating signal Not activated: The pump has been set to stop. 1 3 NC NO C The pump has registered a fault and is unable to 1 2 3 NC NO C run. 0-120, 65-60, 65-120 The function of the signal relay can be changed from "Fault" to "Operating" mode with the R100. The functions of the signal relay are as shown in the table below: Signal relay Fault signal 1 2 3 NC NO C 1 2 3 NC NO C 1 2 3 NC NO C Not activated: The electricity supply has been switched off. The pump has not registered a fault. Activated: The pump has registered a fault. Signal relay Operating signal Not activated: The pump has been set to stop. 1 3 NC NO C The pump has registered a fault and is unable to 1 2 3 NC NO C run. 1 2 3 NC NO C Activated: The pump is running. The pump has registered a fault, but is unable to run. 1 2 3 NC NO C Activated: The pump is running. The pump has registered a fault, but is unable to run. Signal relay Ready signal Not activated: The pump has been set to stop. 1 3 NC NO C The pump has registered a fault and is unable to 1 2 3 NC NO C run. 1 2 3 NC NO C Activated: The pump is ready to run or is running. 15

Functions Analog input External analog control Use of the analog input requires installation of the expansion module, GENI module. Control of setpoint or speed via an external 0-10 V signal. m Max. curve Setpoint/constant curve Min. curve 0 1 2 3 Fig. 12 Example of 0-10 V control 8 9 10 The analog input enables the following control modes: In constant-curve mode, the pump is able to change from one constant curve to another depending on the value of the external signal. The internal controller is inactive in this mode. In pressure control mode, the setpoint can be set externally within the range from the setpoint to the min. curve. The internal controller is active in this mode. 5 At an input voltage lower than 0.5 V, the pump will operate according to the min. curve. 6 7 U V TM00 5550 090 16

Functions Bus communication via GENIbus The bus enables control and monitoring of the pumps from a GRUNDFOS Pump Management System 2000, to a building management system (BMS) or another external control system. BMS BMS LON module TM03 877 207 Fig. 13 Example of single-pump operation TM03 239 005 Fig. 1 Example of single-pump operation 0-120, 65-60, 65-120 BMS Pump type Requires See section GENI module Accessories G-10 LON (Required for 32-100) Bus communication via LON Via the bus input and optional LON module the pump can be connected to a building management sysetm (BMS) based on LonWorks technology, and thus be linked to other units based on this communication standard. pump type GENI module LON module Functions of expansion modules G10-LON 32-100 65-60 0-120 65-120 UPE, single-phase UPE, three-phase Expansion module Fig. 15 Example of single-pump operation 32-100 TM03 301 0106 Pump type Inputs/outputs incorporated With expansion module Function 32-100 0-120 65-60 65-120 Start/stop Signal relay Relay module GENI module GENI module LON module Start/Stop Signal relay Start/Stop Max. curve Min. curve 0-10 V analog input Signal relay Duty/Standby for two pumps in parallel GENIbus Max. curve Min. curve 0-10 V analog input Duty/Standby for two pumps in parallel GENIbus LonTalk protocol, FTT10 17

Construction The is of the canned-rotor type. The pump and motor form an integral unit without shaft seal and with only two gaskets for sealing. The bearings are lubricated by the pumped liquid. The pump features are controller integrated in the terminal box control panel on the terminal box terminal box prepared for optional modules differential-pressure and temperature detection cast-iron or stainless-steel pump housing no external motor protection required. Motor and electronic controller The single-phase motor is a - or 8-pole, synchronous, permanent-magnet motor (PM motor). This motor type has higher efficiency than a conventional asynchronous squirrel-cage motor. Pump speed is controlled by an integrated frequency converter. Pump connections 32-100:Two bolt oval flange. Matches GF 15/26. 0-120: Two bolt oval combination flange. Matches GF15/26 and GF 0/3. 65-60 and 65-120: GF53, bolt Non ANSI flange. Can be connected to GF53, 2", 2.5" and, 3" counter flanges. Paint Enamel paint. Color: Grundfos Red (NCS0-50R) 18

Construction Material specification Pos. Component Material EN AISI/ASTM 1 Terminal box Aluminium/composite 2 Stator housing Aluminium AlSi 10Cu 2 O-rings EPDM rubber Outer bearing ring Aluminium oxide Al 2 O 3 3 1.301 or Rotor can Stainless steel 1.01 30 or 316 Shaft Stainless steel 1.01 316 5 Thrust bearing Carbon MY 106 Bearing plate Stainless steel 1.301 30 6 Inner bearing ring Aluminium oxide Al 2 O 3 7 Impeller Stainless steel 1.301 30 8 Pump housing Cast iron or stainless steel EN-GJL250 1.308 A8 CL35 CF8 5 2 6 7 3 1 8 TM03 1955 5110 Fig. 16 32-100 1 2 3 5 6 7 8 TM02 1256 0801 Fig. 17 0-120, 65-60 and 65-120 19

Installation Mechanical installation is for indoor installation. The pump shaft shall be installed horizontally. may be installed in horizontal as well as vertical pipes as long as the pump shaft is parallel to the ground. Pump shaft shall not be installed vertically. Arrows on the pump housing indicate the liquid flow direction through the pump. The liquid flow direction can be horizontal or vertical, depending on the terminal box position. The terminal box can be turned to various positions. This is described in the installation and operating instructions. The pump must be installed in such a way that strain from the pipework is not transferred to the pump housing. The pump may be suspended direct in the pipes, provided the pipework can support the pump. If not, the pump must be installed on a mounting bracket or base plate. To ensure cooling of motor and electronics, the following must be observed: Place the pump in such a way that sufficient cooling is ensured. The temperature of the cooling air must not exceed 10 F (0 C.) 20

Installation Electrical connection The electrical connection and protection should be carried out in accordance with local regulations. The pump must be connected to an external mains switch. The pump must always be correctly grounded. The pump requires no external motor protection. The motor incorporates thermal protection against slow overloading and blocking (IEC 3-11: TP 211). When the pump is switched on via the mains, the pump will start after approx. 5 seconds. Note: The number of starts and stops via the mains supply must not exceed times per hour. The pump mains connection must be made as shown in the diagrams on the following pages. Cables Use screened cables (0.25-1.5 mm 2 ) for external on/off switch, digital input, sensor and setpoint signals. All cables used must be heat-resistant up to at least 185 F (+85 C). All cables used must be installed in accordance with NEC, local codes and regulations. Wiring diagram External switch L2 ELCB Max. 10 A/16 A L1 TM03 2397 005 Fig. 18 1 x 230 V +/-10%, 50/60 z Additional protection If the pump is connected to an electric installation where an earth-leakage circuit breaker (ELCB) is used as an additional protection, the earth-leakage circuit breaker must be marked with the following symbols. The earth-leakage circuit breaker must trip out when earth fault currents with DC content (pulsating DC) occur. Mains connection Signal output Start/stop Potential-free relay input Fig. 19 0-120, 65-120, 65-60, mains connection Note: If no external on/off switch is connected, the connection across terminals STOP and should be maintained. TM02 0235 1007 21

Installation Two pumps in parallel Two pumps plumbed in parallel can communicate each other with the help of optional GENI module. The modules have to be connected to each other with a wire. L N NC NO C 1 2 3 S T O P 8 7 A Y B 10 V X Q Z 5 6 7 9 10 1112 21 22 23 Wiring diagrams: Master pump, see fig. 20. Slave pump, see fig. 21. Operating modes: Alternating operation Pump operation alternates every 2 hours. If the duty pump stops due to a fault, the other pump will start. Standby operation One pump is operating continuously. In order to prevent seizing-up, the other pump will start at a fixed frequency and run for a short period. If the duty pump stops due to a fault, the other pump will start. L N NC NO C 1 2 3 S T O P 8 7 A Y B 10 V X Q Z Fig. 21 Two pumps in parallel, slave Max. ø7 TM02 080 100 5 6 7 9 10 1112 21 22 23 Max. ø7 TM02 081 100 Max. OD: 0.275 inches (7 mm) Max. OD: 0.275 inches (7 mm) Fig. 20 Two pumps in parallel, master 22

Installation Examples of connections Connection to external controllers L N NC NO C S T O P 1 2 3 8 7 Mains connection Operation Alarm Stop Start Dry-running protection TM02 1322 3601 Fig. 22 Example of pump Connection to external controllers L N NC NO C S T O P A Y B X Q Z 10 V 1 2 3 8 7 5 6 7 9 10 11 12 21 22 23 GENIbus Alarm Mains connection STOP 10 V Setpoint setting DC 0-10 V Stop Start Frost protection TM02 1323 5101 Fig. 23 Example of pump with GENI module 23

Curve conditions Curve conditions The guidelines below apply to the performance curves on pages 26 to 32: The bold parts of the curves show the recommended performance range. Test liquid: Airless water. All curves show average values and should not be used as guarantee curves. If a stated minimum performance is required, individual measurements must be made. has been tested at 10 F (60 C.) The conversion between head [ft] and pressure [psi] has been made for water at 10 F (60 C) SG= 0.983. For liquids with other specific gravities, e.g. hot water, the discharge pressure is proportional to the specific gravities. The pumps should not be used at a minimum flow rate lying outside the areas indicated by the bold-faced curves due to danger of pump overheating. Note: Within 's performance range, the constant- and proportional-pressure curves can be set in steps of 3.3 ft (1 m) head on the control panel and 0.33 ft (0.1 m) head with the R100. 2

Curve conditions This page intentionally left blank. 25

Performance curves/ technical data 32-100 F 32-100 F [m] 12 [ft] 0 Proportional pressure [ft] 0 Constant pressure 36 36 10 32 32 8 28 2 28 2 6 20 16 12 20 16 12 2 0 P1 [W] 200 8 0 P1 [hp] 0.30 0 10 20 30 0 50 60 8 0 P1 [hp] 0.30 0 10 20 30 0 Q [US GPM] 0.25 0.25 150 0.20 0.20 100 0.15 9 8 7 6 5 3 2 0.15 9 8 7 6 5 3 2 1 0.10 0.10 50 0.05 0.05 0 0.00 0.00 0 10 20 30 0 Q [US GPM] 0 2 6 8 10 Q [m³/h] 0 10 20 30 0 Q [US GPM] 0 2 6 8 10 Q [m³/h] TM0 909 110 26

Performance curves/ technical data 32-100 F Electrical data U n [V] P 1 [W] I 1/1 [A] Min. 10 0.1 A 1 x 230-20 Max. 180 1.23 A TM0 93 5110 Dimensions Pump type 32-100 F Dimensions L1 B1 B2 B 1 2 3 D1 D2 D [in] 6 1/2 2 3/8 3 3/8 2 3/8 1 1/ 6 1/8 7 3/8 1 1/ 2 1/ 3 7/8 [mm] 165 61.5 86.9 61.5 32.3 15.5 186.8 31.1 58.5 97.1 Weights Weights Pump type [lb (kg)] Gross 32-100 F 13 (6) 27

Performance curves/ technical data 65-60 F 65-60 F [m] 6 [ft] 20 18 Proportional pressure [ft] 20 18 Constant pressure 5 16 16 1 12 1 12 3 10 10 8 8 2 6 6 1 2 2 0 P1 [W] 500 0 P1 [hp] 0.7 0 20 0 60 80 100 Q [US GPM] 0 P1 [hp] 0.7 0 20 0 60 80 100 Q [US GPM] 00 0.6 0.5 0.6 0.5 300 0. 0. 200 0.3 5 3 2 0.3 5 3 2 0.2 0.2 100 0.1 0.1 0 0.0 0 20 0 60 80 100 Q [US GPM] 0 5 10 15 20 25 Q [m³/h] 0.0 0 20 0 60 80 100 Q [US GPM] 0 5 10 15 20 25 Q [m³/h] TM03 8792 2507 28

Performance curves/ technical data 65-60 F Electrical data U n [V] P 1 [W] I 1/1 [A] 65-60 F is also available with stainless-steel Min. 25 0.17 housing, type N. 1 x 230 V Max. 50 2.0 D B2 1 3 2 B5 D3 D1 L1 B1 M L3 NPT 1/ B B6 B3 B7 D5 D2 TM03 9058 3307 Dimensions Pump type 65-60 F Dimensions L1 L3 B1 B2 B3 B B5 B6 B7 1 2 3 D1 D2 D3 [in] 11 1/2 5 3/ 3 1/16 15/16 3 7/16 1/8 3 3/* 5 1/2 5/16 3 1/ 9 15/16 13 1/8 3/16 2 1/2 3 15/16 5 [mm] 292 16 77 125 88 10 96* 10 110 82 252 33 107 63 100 127 Dimensions Pump type D D5 M [in] 6 5/8 65-60 F M12 [mm] 152 16 * Stainless steel pump housing 3 1/8 [in]/80 [mm] Weights Weights [lb/kg] Pump type Net Gross 65-60 F 8.5/22 53/2 29

Performance curves/ technical data 0-120 F 0-120 F [m] [ft] Proportional pressure [ft] Constant pressure 12 0 0 36 36 10 32 32 8 28 2 28 2 6 20 20 16 16 12 12 2 0 P1 [W] 500 8 0 P1 [hp] 0.7 0 10 20 30 0 50 60 70 Q [US GPM] 8 0 P1 [hp] 0.7 0 10 20 30 0 50 60 70 Q [US GPM] 0.6 0.6 00 0.5 0.5 10 8 6 10 8 6 300 0. 0. 200 0.3 0.3 0.2 0.2 100 0.1 0.1 0 0.0 0 10 20 30 0 50 60 70 Q [US GPM] 0 5 10 15 Q [m³/h] 0.0 0 10 20 30 0 50 60 70 Q [US GPM] 0 5 10 15 Q [m³/h] TM03 8793 2507 30

Performance curves/ technical data 0-120 F Electrical data U n [V] P 1 [W] I 1/1 [A] 0-120 F is also available with stainless-steel Min. 25 0.17 housing, type N. 1 x 230 V Max. 50 2.0 D7 B2 1 3 2 B5 D6 D5 L1 B1 D M L3 NPT Rp 1/ B B3 D1 B6 B7 D2 D3 TM03 9055 3207 Dimensions and weights Pump type 0-120 F Dimensions L1 L3 B1 B2 B3 B B5 B6 B7 1 2 3 D1 D2 D3 [in] 8 1/2 1/ 3 1/16 1/2 2 15/16 3 1/8 3 3/* 5 1/2 5/16 2 11/16 9 1/2 12 3/16 3 3/ 1 9/16 2 15/16 3 1/8 or 3 7/16 [mm] 216 108 77 115 75 80 96* 10 110 68 22 310 96 0 75 80 or 87 Dimensions Pump type D D5 D6 D7 M [in] 3/ 1/2 1 15/16 2 3/8 0-120 F M12 [mm] 120 12 9 60 * Stainless steel pump housing 3 1/8 [in]/80 [mm] Weights Weights [lb/kg] Pump type Net Gross 0-120 F 3/15.5 38/17.5 31

Performance curves/ technical data 65-120 F 65-120 F [m] 1 12 [ft] 8 0 Proportional pressure [ft] 8 0 Constant pressure 36 36 10 32 32 8 28 2 28 2 6 20 20 16 16 12 12 2 0 P1 [W] 8 0 P1 [hp] 1.3 1.2 0 20 0 60 80 100 120 Q [US GPM] 8 0 P1 [hp] 1.3 1.2 0 20 0 60 80 100 120 Q [US GPM] 800 1.1 1.0 1.1 1.0 0.9 0.9 600 0.8 0.7 10 8 6 0.8 0.7 10 8 6 00 0.6 0.5 0.6 0.5 0. 0. 200 0.3 0.3 0.2 0.2 0.1 0.1 0 0.0 0 20 0 60 80 100 120 Q [US GPM] 0 5 10 15 20 25 30 Q [m³/h] 0.0 0 20 0 60 80 100 120 Q [US GPM] 0 5 10 15 20 25 30 Q [m³/h] TM03 879 2507 32

Performance curves/ technical data Electrical data U n [V] P 1 [W] I 1/1 [A] 65-120 F is also available with stainless-steel Min. 35 0.28 housing, type N. 1 x 230 V Max. 900 3.9 D B2 1 3 2 B5 D3 D1 L1 NPT 1/ B1 M B B6 B3 B7 L3 D5 D2 TM03 9058 3307 Dimensions and weights Pump type 65-120 F Dimensions L1 L3 B1 B2 B3 B B5 B6 B7 1 2 3 D1 D2 D3 [in] 11 1/2 5 3/ 3 1/16 15/16 3 7/16 1/8 3 3/* 5 1/2 5/16 3 1/ 9 15/16 13 1/8 3/16 2 1/2 3 15/16 5 [mm] 292 16 77 125 88 10 96* 10 110 82 252 33 107 63 100 127 Dimensions Pump type D D5 M [in] 6 5/8 65-120 F M12 [mm] 152 16 * Stainless steel pump housing 3 1/8 [in]/80 [mm] Weights Weights [kg] Pump type Net Gross 65-120 F 56/25.5 60.5/27.5 33

Accessories Packaged fitting sets Flange sets Pump connection Flange sets include: 2 each - flanges, gaskets, bolts with nuts. Use bronze counter flange for stainless steel Cast iron Bronze Pipe connection type & size NPT Material number Approx. ship. wt. (lb/oz.) 3/ 519601 2 lb oz. GF 15/26 flange 1 519602 2 lb oz. 1-1/ 519603 2 lb 2 oz. 1-1/2 51960 2 lb 2 oz. GF 0/3 flange 1-1/2 539605 2 lb 7 oz. GF 53 flange 2 9158910 12 lb 2-1/2 9158911 12 lb 3 9158912 12 lb 3/ 519651 2 lb 2 oz. GF 15/26 flange 1 519652 2 lb 3 oz. 1-1/ 9609356 2 lb 1 oz. GF 0/3 flange 1-1/2 539615 3 lb GF 53 flange 2 9158913 12 lb 2-1/2 915891 12 lb 3 9158915 12 lb 3

Accessories Expansion modules for pumps can be fitted with an optional expansion module enabling communication via external signals (signal transmitters). Product Product number GENI module 60595 LON module 605809 GENI module The GENI module has an input for an external 0-10 VDC analog signal transmitter (terminal 10 V and ). Via this input, the pump can be controlled by an external controller if the pump has been set to one of the following control modes: Constant curve Proportional- or constant-pressure control. The GENI module also incorporates inputs for external signals for the forced-control functions: Max. curve duty Min. curve duty. Input signals Setpoint signals Bus input Max. and min. curve input External potential-free switch. Maximum contact load: 5 V, 1 ma. Screened cable. Maximum loop resistance: 130 Ω. Input for analog 0-10 V signal External signal: 0-10 VDC. Maximum load: 0.1 ma. Screened cable. Grundfos GENIbus protocol, RS-85. Screened cable. Lead cross section: 0.25-1 mm 2. Maximum cable length: 390 ft (1200 m). Fig. 2 Connection of GENI module Product 10 V A Y B X Q Z 5 6 7 9 10 1112 21 22 23 For 32-100 For 0-120, 65-60, 65-120 GENI module 60595 GENI module and 605809 LON module G10-LON required Relay module TM02 0236 1007 35

Accessories LON module The LON module offers the possibility of connecting the pump to a LonWorks network. The module is used for data transmission between a network and the 0-120, 65-60, and 65-120 pumps. Input signals Bus input LonTalk protocol, FTT 10. Non-screened, twisted-pair cable. Lead cross section: 0.25-1 mm 2. A B TM02 0237 090 Fig. 25 Connection of LON module R100 The R100 is designed for wireless communication with the pump. The 100 communicates with the pump via infra-red light. Product Product number R100 96615297 36

Order data, cast iron Pump type Pipe connection [inch] Product number Flange connection 1.25 1.5 2.5 GF 15/26 GF 15/0 GF 53 32-100 F X 65-60 F X 967363 0-120 F X 967389 65-120 F X 967360, stainless steel Pump type Pipe connection [inch] Product number Flange connection 1.5 2.5 GF 15/0 GF 53 65-60 FN X 9673637 0-120 FN X 9673633 65-120 FN X 967362 37

Further product documentation WebCAPS WebCAPS is a Web-based Computer Aided Product Selection program available on www.grundfos.com. WebCAPS contains detailed information on more than 185,000 Grundfos products in more than 22 languages. In WebCAPS, all information is divided into 6 sections: Catalog Literature Service Sizing Replacement CAD drawings. Catalog This section is based on fields of application and pump types, and contains technical data curves (Q, Eta, P1, P2, etc) which can be adapted to the density and viscosity of the pumped liquid and show the number of pumps in operation product photos dimensional drawings wiring diagrams quotation texts, etc. Literature In this section you can access all the latest documents of a given pump, such as product guides installation and operating instructions service documentation, such as Service kit catalog and Service kit instructions quick guides product brochures, etc. Service This section contains an easy-to-use interactive service catalog. ere you can find and identify service parts of both existing and discontinued Grundfos pumps. Furthermore, this section contains service videos showing you how to replace service parts. 38

0 1 Further product documentation Sizing This section is based on different fields of application and installation examples, and gives easy step-by-step instructions in how to select the most suitable and efficient pump for your installation carry out advanced calculations based on energy consumption, payback periods, load profiles, life cycle costs, etc. analyze your selected pump via the built-in life cycle cost tool determine the flow velocity in wastewater applications, etc. Replacement In this section you find a guide to selecting and comparing replacement data of an installed pump in order to replace the pump with a more efficient Grundfos pump. The section contains replacement data of a wide range of pumps produced by other manufacturers than Grundfos. Based on an easy step-by-step guide, you can compare Grundfos pumps with the one you have installed on your site. When you have specified the installed pump, the guide will suggest a number of Grundfos pumps which can improve both comfort and efficiency. CAD drawings In this section it is possible to download 2-dimensional (2D) and 3-dimensional (3D) CAD drawings of most Grundfos pumps. These formats are available in WebCAPS: 2-dimensional drawings:.dxf, wireframe drawings.dwg, wireframe drawings. 3-dimensional drawings:.dwg, wireframe drawings (without surfaces).stp, solid drawings (with surfaces).eprt, E-drawings. WinCAPS Fig. 26 WinCAPS CD-ROM WinCAPS is a Windows-based Computer Aided Product Selection program containing detailed information on more than 185,000 Grundfos products in more than 22 languages. The program contains the same features and functions as WebCAPS, but is an ideal solution if no Internet connection is available. WinCAPS is available on CD-ROM and updated once a year. Subject to alterations. 39

Being responsible is our foundation Thinking ahead makes it possible Innovation is the essence L-MAG-PG-01 11/10 Repl. 1/10 2007, 2010 Grundfos Pumps Corp. US The name Grundfos, the Grundfos logo, and the payoff Be Think Innovate are registrated trademarks owned by Grundfos Management A/S or Grundfos A/S, Denmark. All rights reserved worldwide. GRUNDFOS Pumps Corporation 17100 West 118th Terrace Olathe, Kansas 66061 Phone: +1-913-227-300 Telefax: +1-913-227-3500 www.grundfos.com GRUNDFOS Canada Inc. 291 Brighton Road Oakville, Ontario L6 6C9 Canada Phone: +1-905 829 9533 Telefax: +1-905 829 9512 Bombas GRUNDFOS de Mexico S.A. de C.V. Boulevard TLC No. 15 Parque Industrial Stiva Aeropuerto Apodaca, N.L. Mexico 66600 Phone: +52-81-81 000 Telefax: +52-81-81 010